Dear All,
I would like to ask about extension mobility on my Cisco Unified Call manager 8.5. The problem is when I press services button then Extension Mobility the put the User ID and Pin, the login was successfull but after that there's no change on IP Phone screen.
After I check on Cisco Unified Call Manager -> Devices -> Phone -> Actively Logged In Device Report I was found that my ID already login on IP Phone, but like I say before there's no change on IP Phone, my Directory Number, Name also not appear.
Did anyone experiencing same issue above? Or anyone know how to fix issue above?
Please let me know, I'm very appreciate to all of you that help and contribute on this discussion
Best Regards,
Nanda Nurhadyan       

Nanda,
Have you created a Specific Device Profile with your DN and name? You will need to do that, and then you will need to go in to your end user account and make it a controlled profile.
If you do not have a device profile specific for you, you are probably getting the default device profile that doesn't have any DN associated with it.
Let me know if this helps.
Dallan

Similar Messages

  • Extension Mobility not working during fail over

    Hello All
    I am John.   I have a cluster that has 2 subscribers and 1 publisher.  We are running 8.5.1.  Yesterday I had a case where my one subscriber had failed and everything failed over to the other subscriber.  Everything but extension mobility seemed to work.  I checked all my certs, I checked the services, I checked the url for the services.  Everything seemed to check out correctly.  The url is pointed to the publisher and the publisher was available. 
    What i saw during failover:
    When the services button was activated I received the requesting notice.  after a while the message changed to Host not found.  Then the next message was select service. 
    I did a restart on the extension mobility service with no effect.  The other web applications (such as corp directory) all seem to be working correctly.  Extension Mobility is the only service I have running.
    When the failover ended and my lost subscriber was available, extension mobility and the services started working again. 
    Any help or ideas would be greatly appreciated.
    Thank you
    John

    Hi John,
    As suggested by iptuser55, switch on the EM service on both the nodes. This is the only way failover would work. There are 2 services in CUCM, Extension Mobility and EMApp. The EMApp runs on all the nodes, and its job is to keep a list of the nodes with the EM service activated. When the top node in that list goes down, the EMApp will then point to the next node in the list, which will act as the Failover.
    Here's the architecture of the EM service.
    http://www.cisco.com/c/en/us/td/docs/voice_ip_comm/cucm/srnd/8x/uc8x/cmapps.html#wp1187822

  • Extension mobility not working

    Our users with extension mobility their user not displaying on the phone. However CM shows user logedin into the phone. Check all the services running. Need quick answer. It does not show ipcc extension.

    It took us 5 hours to figure the issue yesterday that Db replication was malfunctoning. We had a failover last week where some users were not able to login into the phones.but resolved on its own everything worked fine until yesterday. We saw some errors AQM server and restarted the services that took care of our CUCM replication issue. What AQM has to do with  it.

  • Tabbing is not working properly / Flex Mobile 4.6

    Hello,
    I've been working on a mobile app in Flex 4.6 and I've noticed that tabbing between fields is not working properly - maybe someone else has had the same experience and has a fix?
    I have 4 TextInput fields, which now all have tabEnabled set to "true" and tabIndex set accordingly, however, I am unable to tab netween the fields.
    More specifically, when I run the app with a destop run configuration, any time I hit the "TAB" button on the keyboard the first field is focused on. So, if the cursor is in field 3 & I hit TAB, the focus is now in field 1.
    On the mobile device (Samsung Galaxy S), there is no tabbing at all, no matter which field I am in. The soft keyboard does detect the last field though, and the "Next" button on the keyboard will change to "Done".
    I've tried putting the TextInput fields withing a SkinnableContainer (as mentioned here: http://forums.adobe.com/message/2418694#2418694), but no change.
    I also found a bug report on something similar, though it was closed becuase it was opened in the AIR bug base instead of the flex bug base. (https://bugbase.adobe.com/index.cfm?event=bug&id=3064944)
    Here's the code for my "registration" view without any functions or function calls.
    <?xml version="1.0" encoding="utf-8"?>
    <s:View xmlns:fx="http://ns.adobe.com/mxml/2009"
                        xmlns:s="library://ns.adobe.com/flex/spark"
                        title="Create Account">
              <fx:Declarations>
                        <!-- Place non-visual elements (e.g., services, value objects) here -->
              </fx:Declarations>
              <s:Group left="10" right="10" top="10" bottom="10">
                        <s:layout>
                                  <s:VerticalLayout/>
                        </s:layout>
                        <s:TextInput id="email" prompt="Email" tabEnabled="true" tabIndex="1"/>
                        <s:TextInput id="un" prompt="Username" tabEnabled="true" tabIndex="2"/>
                        <s:TextInput id="pw" displayAsPassword="true" prompt="Password" tabEnabled="true" tabIndex="3"/>
                        <s:TextInput id="pwc" displayAsPassword="true" prompt="Confirm Password" tabEnabled="true" tabIndex="4"/>
                        <s:Button id="button" width="100%" label="Sign Up"/>
                        <s:Group width="100%">
                                  <s:layout>
                                            <s:VerticalLayout horizontalAlign="center"/>
                                  </s:layout>
                                  <s:BusyIndicator id="bi_reg" visible="false"/>
                                  <s:Label id="msg_reg" width="100%" text="Label" textAlign="center" visible="false"/>
                        </s:Group>
              </s:Group>
    </s:View>

    Thanks for the response. I am using spark TextInput components as you can see in the code above. I've used these conrtols in other apps in FB 4.5 and have had no problems so it seems like something may be different in 4.6, or it's a bug.

  • Dial UP Modem is not working properly in Satellite A200-1GB

    My A200 - 1 GB's modem is not working properly. It tries to connect but at last it says remote computer is not responding. As i noticed It has a "Agree" 56kpbs modem.
    It shown as Toshiba Software Modem.
    I tried so many times it doesn't work properly. I tried by changing the assigned COM ports to several other COM ports like COM1,COM10,COM 4 ext... same thing occurs.
    When I diagnose the modem via the modem properties no matters found.
    Same as when I'm dialing through the modem to a telephone (i mean as a call) it's working properly. I mean it can call to a mobile phone or land phone.
    But the same phone line is working properly with my desktop modem as same as another HP laptop modem.
    It seems there is some malfunction on my 56k modem.
    I tried even uninstalling and reinstalling but still the matter exists.
    Can anybody help me in this case?

    Please check this thread:
    http://forums.computers.toshiba-europe.com/forums/message.jspa?messageID=109510#109510
    Seems you have started two threads about the same theme.

  • Not working properly Computer Browser service in Windows Server 2012

    Good afternoon.
    Migrated from 2003 to 2012 Active Directory, all is good, but the service Computer Browser in Windows Server 2012 is not working properly.
    Online, there are several hundred computers, one network, no segments. PDC is the Master Browser, it is in my list of all the computers, but gives customers or Backup Browser computers only part, and in alphabetical order, giving the first 70 computers and
    all.
    Looked packet sniffer:
    Microsoft Windows Lanman Remote API Protocol 
    Entry Count: 70 
    Available Entries: 251
    So on Master Browser shows 251 computer, and the client 70.
    If disabled on Windows Server 2012 Service Computer Browser, Master Browser is a computer running Windows Server 2003. He gives all computers.
    What is the problem, how to get Windows Server 2012 to work correctly as a Master Browser?

    More info. I have high lighted in bold where the issue is. This is a massive headache for me at the moment
      Frame: Number = 377, Captured Frame Length = 182, MediaType = ETHERNET
    - Ethernet: Etype = Internet IP (IPv4),DestinationAddress:[00-13-72-52-6E-A1],SourceAddress:[00-1E-0B-2B-68-DD]
      - DestinationAddress: Dell Inc. 526EA1 [00-13-72-52-6E-A1]
         Rsv: (000000..)
         UL:  (......0.) Universally Administered Address
         IG:  (.......0) Individual address (unicast)
      - SourceAddress: 001E0B 2B68DD [00-1E-0B-2B-68-DD]
         Rsv: (000000..)
         UL:  (......0.) Universally Administered Address
         IG:  (.......0) Individual address (unicast)
        EthernetType: Internet IP (IPv4), 2048(0x800)
    - Ipv4: Src = 10.44.46.101, Dest = 10.44.44.14, Next Protocol = TCP, Packet ID = 14025, Total IP Length = 168
      - Versions: IPv4, Internet Protocol; Header Length = 20
         Version:      (0100....) IPv4, Internet Protocol
         HeaderLength: (....0101) 20 bytes (0x5)
      - DifferentiatedServicesField: DSCP: 0, ECN: 0
         DSCP: (000000..) Differentiated services codepoint 0
         ECT:  (......0.) ECN-Capable Transport not set
         CE:   (.......0) ECN-CE not set
        TotalLength: 168 (0xA8)
        Identification: 14025 (0x36C9)
      - FragmentFlags: 16384 (0x4000)
         Reserved: (0...............)
         DF:       (.1..............) Do not fragment
         MF:       (..0.............) This is the last fragment
         Offset:   (...0000000000000) 0
        TimeToLive: 128 (0x80)
        NextProtocol: TCP, 6(0x6)
        Checksum: 0 (0x0)
        SourceAddress: 10.44.46.101
        DestinationAddress: 10.44.44.14
    - Tcp: Flags=...AP..., SrcPort=65372, DstPort=NETBIOS Session Service(139), PayloadLen=128, Seq=1910965363 - 1910965491, Ack=580319796, Win=252 (scale factor 0x8) = 64512
        SrcPort: 65372
        DstPort: NETBIOS Session Service(139)
        SequenceNumber: 1910965363 (0x71E70473)
        AcknowledgementNumber: 580319796 (0x2296FA34)
      - DataOffset: 80 (0x50)
         DataOffset: (0101....) 20 bytes
         Reserved:   (....000.)
         NS:         (.......0) Nonce Sum not significant
      - Flags: ...AP...
         CWR:    (0.......) CWR not significant
         ECE:    (.0......) ECN-Echo not significant
         Urgent: (..0.....) Not Urgent Data
         Ack:    (...1....) Acknowledgement field significant
         Push:   (....1...) Push Function
         Reset:  (.....0..) No Reset
         Syn:    (......0.) Not Synchronize sequence numbers
         Fin:    (.......0) Not End of data
        Window: 252 (scale factor 0x8) = 64512
        Checksum: 0x6F65, Disregarded
        UrgentPointer: 0 (0x0)
        TCPPayload: SourcePort = 65372, DestinationPort = 139
    - Nbtss: SESSION MESSAGE, Length =124
        PacketType: SESSION MESSAGE, 0(0x00)
      - Flags: Add 0 to Length
         Reserved: (0000000.)
         Extension: (.......0)Add 0 to Length
        Length: 124(0x7C)
    - SMB: C; Transaction, Remote Administration Protocol, FileName = \PIPE\LANMAN
        Protocol: SMB
        Command: Transaction 37(0x25)
      - NTStatus: 0x0, Facility = FACILITY_SYSTEM, Severity = STATUS_SEVERITY_SUCCESS, Code = (0) STATUS_SUCCESS
         Code:     (................0000000000000000) (0) STATUS_SUCCESS
         Facility: (...0000000000000................) FACILITY_SYSTEM
         Customer: (..0.............................) NOT Customer Defined
         Severity: (00..............................) STATUS_SEVERITY_SUCCESS
      - SMBHeader: Command, TID: 0x2001, PID: 0x276C, UID: 0x3801, MID: 0x0140
       - Flags: 24 (0x18)
          LockAndRead:     (.......0) LOCK_AND_READ and WRITE_AND_UNLOCK NOT supported (Obsolete) (SMB_FLAGS_LOCK_AND_READ_OK)
          NoAck:           (......0.) An ACK response is needed (SMB_FLAGS_SEND_NO_ACK[only applicable when SMB transport is NetBIOS over IPX])
          Reserved_bit2:   (.....0..) Reserved (Must Be Zero)
          CaseInsensitive: (....1...) SMB paths are case-insensitive (SMB_FLAGS_CASE_INSENSITIVE)
          Canonicalized:   (...1....) Canonicalized File and pathnames (Obsolete) (SMB_FLAGS_CANONICALIZED_PATHS)
          Oplock:          (..0.....) Oplocks NOT supported for OPEN, CREATE & CREATE_NEW (Obsolete) (SMB_FLAGS_OPLOCK)
          OplockNotify:    (.0......) Notifications NOT supported for OPEN, CREATE & CREATE_NEW (Obsolete) (SMB_FLAGS_OPLOCK_NOTIFY_ANY)
          FromServer:      (0.......) Command - SMB is being sent from the client (SMB_FLAGS_SERVER_TO_REDIR)
       - Flags2: 51207 (0xC807)
          KnowsLongFiles:            (...............1) Understands Long File Names (SMB_FLAGS2_KNOWS_LONG_NAMES)
          KnowsEas:                  (..............1.) Understands extended attributes (SMB_FLAGS2_KNOWS_EAS)
          SmbSecuritySignature:      (.............1..) Security signatures enabled (SMB_FLAGS2_SMB_SECURITY_SIGNATURE)
          Compressed:                (............0...) Compression Disabled for REQ_NT_WRITE_ANDX and RESP_READ_ANDX (SMB_FLAGS2_COMPRESSED)
          SecuritySignatureRequired: (...........0....) Security Signatures are NOT required (SMB_FLAGS2_SMB_SECURITY_SIGNATURE_REQUIRED)
          Reserved_bit5:             (..........0.....) Reserved (Must Be Zero)
          IsLongName:                (.........0......) DO NOT use Long File Names (SMB_FLAGS2_IS_LONG_NAME)
          Reserved_bits7_9:          (......000.......) Reserved (Must Be Zero)
          ReparsePath:               (.....0..........) NOT a Reparse path (SMB_FLAGS2_REPARSE_PATH)
          ExtendedSecurity:          (....1...........) Aware of extended security (SMB_FLAGS2_EXTENDED_SECURITY)
          Dfs:                       (...0............) NO DFS namespace (SMB_FLAGS2_DFS)
          Paging:                    (..0.............) Read operation will NOT be permitted unless user has permission (NO Paging IO) (SMB_FLAGS2_PAGING_IO)
          NTStatus:                  (.1..............) Using 32-bit NT status error codes (SMB_FLAGS2_NT_STATUS)
          Unicode:                   (1...............) Using UNICODE strings (SMB_FLAGS2_UNICODE)
         PIDHigh: 0 (0x0)
         SecuritySignature: 0x0
         Unused: 0 (0x0)
         TreeID: 8193 (0x2001)
         ProcessID: 10092 (0x276C)
         UserID: 14337 (0x3801)
         MultiplexID: 320 (0x140)
      - CTransaction:
         WordCount: 14 (0xE)
         TotalParameterCount: 32 (0x20)
         TotalDataCount: 0 (0x0)
         MaxParameterCount: 8 (0x8)
         MaxDataCount: 4200 (0x1068)
         MaxSetupCount: 0 (0x0)
         Reserved: 0 (0x0)
       - Flags: Do NOT disconnect TID
          Disconnect: (...............0) Do NOT disconnect TID
          NoResponse: (..............0.) Server response to the client
          Reserved:   (00000000000000..) Reserved
         Timeout: 5000 milli sec(s)
         Reserved2: 0 (0x0)
         ParameterCount: 32 (0x20)
         ParameterOffset: 92 (0x5C)
         DataCount: 0 (0x0)
         DataOffset: 0 (0x0)
         SetupCount: 0 (0x0)
         Reserved3: 0 (0x0)
         ByteCount: 61 (0x3D)
       - RemoteAPIBuffer:
        - FileName: \PIPE\LANMAN
         - Align: 1 Bytes
            AlignBytes: Binary Large Object (1 Bytes)
           Name: \PIPE\LANMAN
          Pad1: Binary Large Object (2 Bytes)
    - RAPRequest: NetServerEnum2 Request, InfoLevel = 1, SV_TYPE_ALL: All in NSNET
        RAPOpcode: NetServerEnum2
      - ParameterDescriptor: WrLehDz; 4 send, 1 receive parameter
         Param: (W) WORD (send parameter, 16 bit integer)
         Param: (r) Receive buffer (format in data descriptor) (receive data, 0 bit integer)
         Param: (L) Receive buffer length (send/receive parameter, 16/16 bit integer)
         Param: (e) Entries read (receive data, 0 bit integer)
         Param: (h) WORD (receive parameter, 16 bit integer)
         Param: (D) DWORD (send parameter, 32 bit integer)
         Param: (z) ASCIIZ (send parameter, 8 bit integer)
         Param: ASCII NUL (string terminator)
      - DataDescriptor: B16BBDz; data bytes send: 0, receive: 34
       - Datum: (B) BYTE[16] (receive data, 8 bit integer)
          Datum: (B) BYTE (receive data, 8 bit integer)
          Digit: 1
          Digit: 6
         Datum: (B) BYTE (receive data, 8 bit integer)
         Datum: (B) BYTE (receive data, 8 bit integer)
         Datum: (D) DWORD (receive data, 32 bit integer)
         Datum: (z) ASCIIZ* (receive data offset, 32 bit integer)
         Datum: ASCII NUL (string terminator)
      - NetServerEnum2: SV_TYPE_ALL: All in NSNET
         InfoLevel: (1) SERVER_INFO_1
         ReceiveBufferSize: 4200 (0x1068)
       - ServerType: SV_TYPE_ALL: All
          Workstation:      (...............................1) All workstations
          Server:           (..............................1.) All computers with the server service running
          Sqlserver:        (.............................1..) All running Microsoft SQL Server
          DomainCtrl:       (............................1...) All primary domain controllers
          DomainBakctrl:    (...........................1....) All backup domain controllers
          TimeSource:       (..........................1.....) All Time servers
          AFP:              (.........................1......) All Apple File Protocol servers
          Novell:           (........................1.......) All Novell servers
          DomainMember:     (.......................1........) All LAN Manager 2.x domain members
          PrintqServer:     (......................1.........) All print servers
          DialinServer:     (.....................1..........) All dial-in servers
          ServerUnix:       (....................1...........) All Unix/Xenix servers
          NT:               (...................1............) All Windows NT workstations or servers
          WFW:              (..................1.............) All Windows for Workgroups servers
          ServerMFPN:       (.................1..............) All Microsoft File and Print for NetWare servers
          ServerNT:         (................1...............) All non-domain controller servers
          PotentialBrowser: (...............1................) All servers that can run the browser service
          BackupBrowser:    (..............1.................) All backup browsers
          MasterBrowser:    (.............1..................) All master browsers
          DomainMaster:     (............1...................)  All domain master browsers
          Reserved1:        (..........11....................)
          Windows:          (.........1......................) All Windows 95 or later
          DFS:              (........1.......................) All DFS root servers
          ClusterNT:        (.......1........................) All NT Clusters
          Terminalserver:   (......1.........................) All Terminal Servers
          ClusterVSNT:      (.....1..........................) All NT Cluster Virtual Server Names
          DCE:              (....1...........................) AllIBM DSS (Directory & Security Services)
          Reserved2:        (...1............................)
          AlternateXport:   (..1.............................) Return list for alternate transport
          LocalListOnly:    (.1..............................) Return local list only
          DomainEnum:       (1...............................) Enumerate primary domain
         Domain: NSNET
    Then the reply;
        Frame: Number = 378, Captured Frame Length = 1514, MediaType = ETHERNET
    + Ethernet: Etype = Internet IP (IPv4),DestinationAddress:[00-1E-0B-2B-68-DD],SourceAddress:[00-13-72-52-6E-A1]
    + Ipv4: Src = 10.44.44.14, Dest = 10.44.46.101, Next Protocol = TCP, Packet ID = 27036, Total IP Length = 1500
    + Tcp: Flags=...A...., SrcPort=NETBIOS Session Service(139), DstPort=65372, PayloadLen=1460, Seq=580319796 - 580321256, Ack=1910965491, Win=253 (scale factor 0x8) = 64768
    + Nbtss: SESSION MESSAGE, Length =2013
    + SMB: R; Transaction, Remote Administration Protocol
    - RAPResponse: NetServerEnum2 Response, Count = 31
        Win32ErrorCode: 0x00000000 - ERROR_SUCCESS - The operation completed successfully.
        Converter: 2251 (0x8CB)
      - NetServerEnum2: Count = 31
         EntriesReturned: 31 (0x1F)
         EntriesAvailable: 31 (0x1F)
       + NetServerInfo1: APOLLO
       + NetServerInfo1: ARTEMIS
       + NetServerInfo1: ASKLEPIOS
       + NetServerInfo1: CASTOR
       + NetServerInfo1: DCC4503-131L
       + NetServerInfo1: DCC4503-155L
       + NetServerInfo1: DCC4503-157L
       + NetServerInfo1: DCC4503-161L
       + NetServerInfo1: DCC4503-171L
       + NetServerInfo1: DCC4503-172L
       + NetServerInfo1: DCC4503-175L
       + NetServerInfo1: DCC4503-177L
       + NetServerInfo1: DCC4503-183L
       + NetServerInfo1: DCC4503-184L
       + NetServerInfo1: DCC4503-185L
       + NetServerInfo1: DCC4503-188L
       + NetServerInfo1: DCC4503-196L
       + NetServerInfo1: DCC4503-197L
       + NetServerInfo1: DCC4503-199L
       + NetServerInfo1: DCC4503-202L
       + NetServerInfo1: DCC4503-203L
       + NetServerInfo1: DCC4503-205L
       + NetServerInfo1: DCC4503-210L
       + NetServerInfo1: DCC4503-213L
       + NetServerInfo1: DCC4503-219L
       + NetServerInfo1: DCC4503-220L
       + NetServerInfo1: DCC4503-228L
       + NetServerInfo1: DCC4503-233L
       + NetServerInfo1: DCC4503-234L
       + NetServerInfo1: DCC4503-236L
       + NetServerInfo1: DCC4503-241L
        StringData: Binary Large Object (586 Bytes)

  • The list of extensions for InDesign now have a yellow triangle warning symbol in front of a good many of the extensions and when moused over i get one of two messages:  "Extensions may not function properly because it does not meet the dependency conditio

    The list of extensions for InDesign now have a yellow triangle warning symbol in front of a good many of the extensions and when moused over i get one of two messages:
    "Extensions may not function properly because it does not meet the dependency condition."
    OR
    Extension Status is not consistent with extension set configuration."
    The reason I opened the Extension Manager in the first place was to check to see if I had installed a third party extension.  And I was presented with these warning symbols.  I haven't added anything, I haven't done anything that would cause this.
    Does anyone know how to fix this???
    I am running OSX 10.9.5; Indesign CS6 version 8.0.2 And Adobe Extension Manager version  6.0.8.28.
    Thanks in advance!
    Nina

    Many InDesign pre-installed extensions (Those extensions you have immediately after InDesign installation) define dependency rules in their mxi files. Dependency means that one extension works well only if one or more other extensions are installed and enabled. If this condition is not met, the yellow triangle warning will be shown.
    You can select an extension with warning, click "Advanced" tag page in the lower right panel. You will see "This extension has dependency on: <extension name> ...". Check whether every extensions listed here are available and enabled. If not, enable them. Repeat these steps for all the extensions which have warning.

  • Bbm not working properly

    BBM on my Z10 is not working properly. My service provider is airtel n according to them there is a problem with my handset. what should i do?

    Do you have a BlackBerry Data Plan enabled on your account with your carrier or mobile provider?
    1. If any post helps you please click the below the post(s) that helped you.
    2. Please resolve your thread by marking the post "Solution?" which solved it for you!
    3. Install free BlackBerry Protect today for backups of contacts and data.
    4. Guide to Unlocking your BlackBerry & Unlock Codes
    Join our BBM Channels (Beta)
    BlackBerry Support Forums Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • Applemobiledevice not working properly message

    Just downloaded the latest itunes. Every time I open itunes there's an "apple mobile device not working properly" message that continually pops up and it won't stop. I use Vista and have no clue how to stop it. Can anyone help?

    Take a look here:
    http://discussions.apple.com/ann.jspa?annID=640
    Selective startup info:
    http://support.microsoft.com/kb/310560
    Hope that helps.
    Forum Tip: Since you're new here, you've probably not discovered the Search feature available on every Discussions page, but next time, it might save you time (and everyone else from having to answer the same question multiple times) if you search a couple of ways for a topic, both in the relevant forums, in the User Tips Library and in the Apple Knowledge Base before you post a question.
    Regards.

  • Firefox firebug not working properly since last one week.

    Firebug addon is not displaying icon and not working properly. Anybody have any idea about this.Thanks in advance.

    My Firebug is still working.
    * What version are you using ?
    * As a troubleshooting step Try in a new Firefox profile. Disable all extensions and Plugins other than Firebug in the new profile.
    **[[Use the Profile Manager to create and remove Firefox profiles]]
    *The Firebug mailing list may be able to help
    ** https://getfirebug.com/community

  • The Connect from Intel Pro/1000 T to 1000base-t Port on Catalyst 4000 (WS-X4412-2GB-T= module) Not Working Properly

    The connect from Intel Pro/1000 T to 1000base-t port on Catalyst 4000 (WS-X4412-2GB-T= module) is not working properly. The Intel Pro/1000 T NIC connects to a 10/100 OK. Auto-negotiation is set at both ends. We can successfully ping across the link. However performance is so poor as to make the connection unusable.

    When an Intel Pro/1000 T NIC is connected to a Catalyst switch, the customer may see poor network connections or excessive numbers of dropped packets. The problem arises when a module with a TBI interface transmits an odd byte packet to a receiver with a Gigabit Media Independent Interface (GMII).
    The interoperability issue is a result of the implementation of Carrier Extension. Carrier Extension is detailed in sub section 35.2.3.5 in the IEEE 802.3 specification. Carrier Extension can be used to pad the last byte of a packet, so the packet is aligned on an even numbered boundary.

  • Hi i buy G62 but the drivers for gaming is not working properly is there a way that i can download

    My gaming driver is not working properly Im using a ATI MOBILITY RADEON HD 4200 how can i download a new driver suit to my computer and where its nposeble to download it thanks in advance.

    Firefox will not appear in the Market for most phones with incompatible hardware. You can check if your phone is supported here:
    https://wiki.mozilla.org/Mobile/Platforms/Android
    Even on some supported devices, a bug in the Market software prevents Firefox from showing up. This may be related to the fairly recent Android Market app update. If you go to Settings/Applications/Market and choose "Uninstall" you can uninstall the update, and then search for and install Firefox from the marketplace.
    Or, if you have a supported phone, you can download the app directly by typing this address into your phone's browser: http://bit.ly/fxbeta3
    (Note: To download the app directly for an AT&T phone, you will have to search for instructions on "sideloading" the APK file, since AT&T disables the option to install from non-Market sources.)

  • This page contains some SWF objects that may not work properly...

    Hello Guys
    I bought this menu made by f-source into my page:
    http://beta.asphalt-driveway-sealing.com/, it's working fine except I got this message each time I am opening my file with dreamweaver CS4: 'this page contains some SWF objects that may not work properly in the most recent versions of Internet Explorer. Dreamweaver cannot  convert them to the new SWF markups. Please delete each of them and insert again' and what I did but still got this message
    the developer told me that: "I previous versions of Dreamweaver you could disable the Active
    Content Converter http://f-source.com/before_insert/
    In CS4 there is no such option."
    Please let me know what can I do then.
    Many Thanks, T&T

    Hi
    CS4 uses a 'nested' type of object code to insert swf/flv files, which is more compliant than previous code. Obviously the f-source extension is not cs4 compliant if it is changing this, (the message indicates it is doing so) and is something you should pursue via there support department. However even though it is giving you this message it should still work on live pages.
    PZ
    www.pziecina.com

  • Curve 9300 3G - A few Keys not working properly

    Somebody close had gifted this Blackberry Curve 9300 3G mobile to me. After using it for just 2 months, the Space, alt and 0 keys are not working properly. At times I just have to keep pressing for these respective keys to respond and at times upon pressing, these keys respond more than once. Does anybody know how to tackle this issue.
    Regds
    AK

    Maybe your Keypad Membrane not working 

  • Extension may not function properly...

    My co-worker has been having some issues with her InDesign crashing latley. I opened up her Extensions manager just to see if I could find anything abnormal, and found alot of the extensions for InDesign have little yellow triangle warnings next to them. When I hover the mouse above it, it says "Extension may not function properly because it does not meet the dependency condition. I don't know what this means, or what should be done to resolve the issue.
    I checked my extensions manager on my computer at work, and i don't have any of these warnings on my InDesign extensions. So, I'm thinking this might be the cause of her InDesign crashing, but not sure.
    I clicked on the checkmark of one of her extensions, Assignment UI, to disable it, but not sure if I should do the same with the rest of them. After I disabled it, I can't see how to re-enable it. I try to click back on the box to enable it, but it doesn't do anything.
    She was just upgraded to OSX 9 Maverick today, but prior to that was using OSX 10.7.xx (Whatever the latest version was). I am currently using OSX 10.8.5, but wil be upgrading to Maverick soon as well.
    We are both using Mac 2.66 GHz Quad-Core Intel Macs with 16 GB memory. Both are using CS6, with the latest updates for InDesign applied.
    If anyone has any ideas on what to do with her extensions that have warnings it would be appreciated.
    Steve

    Many InDesign pre-installed extensions (Those extensions you have immediately after InDesign installation) define dependency rules in their mxi files. Dependency means that one extension works well only if one or more other extensions are installed and enabled. If this condition is not met, the yellow triangle warning will be shown.
    You can select an extension with warning, click "Advanced" tag page in the lower right panel. You will see "This extension has dependency on: <extension name> ...". Check whether every extensions listed here are available and enabled. If not, enable them. Repeat these steps for all the extensions which have warning.

Maybe you are looking for

  • Just Static Instead of Audio When Recording Videos

    Just updated to 4.1 and no dice. Whenever I record videos it does not record audio as well, just static. When I first had the phone it worked fine. I've read other forum posts about it and not found anything useful to attempt. Fairly annoyed that I s

  • Itunes installation doesnt work because of Quicktime

    I've had an ipod for a while, and then we switched to XP PRO for increased security. After sometime itunes stopped working. So my dad and i have used like every uninstaller and remover and some piece of quicktime is still somewhere on my computer. Wh

  • BAPI to do save as completed  a journal

    Hi We need a BAPI to park or save as completed a Journal.Inspecific we want to have save as completed of a Journal through BAPI.

  • Adding an application component - missing something obvious

    Hi, We just upgraded to portal (running server and portal on windows nt) and I am developing. We have reports already completed in reports 6i. However, I am having trouble adding them to the pages or even in the "other providers" listed in portlet re

  • Unable to View the Other User's Developed Interfaces

    Hi All, One of my colleague has developed 3 interfaces with his ID in Repository. He is able to view and test all those scenarios. but if i login with my ID means , iam unable to see those Scenarios at all in IR Before this iam able to view if he dev