Failed to install Workflow

I used wfinstall.csh to install Workflow. It reported error. Flowing is the content of log. How to solve it?
WFCA OUT: Error: Unable to install datasource: Cannot create connection pool. A connection pool named 'jdbc/WorkflowDS_connectionPool' already exists.
WorkflowCA: Exit Val: 1
WorkflowCA: Created a redirected data source with application WFALSNRSVCApp :
WorkflowCA: Executing :/oracle/product/11.2.0/dbhome_1/jdk/bin/java -jar /oracle/product/11.2.0/dbhome_1/oc4j/j2ee/home/admin.jar ormi://jie-rhel:6041 oc4jadmin welcome -application WFMLRSVCApp -testDataSource -location jdbc/WorkflowDS -username OWF_MGR
WorkflowCA: :nullApr 28, 2010 11:33:06 PM oracle.j2ee.rmi.RMIMessages EXCEPTION_ORIGINATES_FROM_THE_REMOTE_SERVERWARNING: Exception returned by remote server: {0}java.rmi.RemoteException: ORA-01017: invalid username/password; logon denied     at com.evermind.server.administration.DefaultApplicationAdministrator.testDataSource(DefaultApplicationAdministrator.java:1230)     at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)     at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39)     at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)     at java.lang.reflect.Method.invoke(Method.java:585)     at com.evermind.server.rmi.RmiMethodCall.run(RmiMethodCall.java:53)     at com.evermind.util.ReleasableResourcePooledExecutor$MyWorker.run(ReleasableResourcePooledExecutor.java:303)     at java.lang.Thread.run(Thread.java:595)Data source jdbc/WorkflowDS is not available. for app:WFMLRSVCApp
WorkflowCA: Executing: /oracle/product/11.2.0/dbhome_1/jdk/bin/java -jar /oracle/product/11.2.0/dbhome_1/oc4j/j2ee/home/admin.jar ormi://jie-rhel:6041 oc4jadmin welcome -application WFMLRSVCApp -installDataSource -url jdbc:oracle:thin:@(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(HOST=localhost)(PORT=1521)))(CONNECT_DATA=(SERVICE_NAME=orcl))) -username OWF_MGR -password ->pwForOwfMgr -className com.evermind.sql.DriverManagerDataSource -location jdbc/WorkflowDS -xaLocation jdbc/xa/WorkflowDS -ejbLocation jdbc/WorkflowDS -connectionDriver oracle.jdbc.driver.OracleDriver
WFCA OUT: Apr 28, 2010 11:33:07 PM oracle.j2ee.rmi.RMIMessages EXCEPTION_ORIGINATES_FROM_THE_REMOTE_SERVER
WFCA OUT: WARNING: Exception returned by remote server: {0}
WFCA OUT: oracle.oc4j.sql.DataSourceException: Cannot create connection pool. A connection pool named 'jdbc/WorkflowDS_connectionPool' already exists.
WFCA OUT:      at com.evermind.server.ApplicationStateRunning.initDataSourceConnectionPool(ApplicationStateRunning.java:2064)
WFCA OUT:      at com.evermind.server.Application.createDataSourceConnectionPool(Application.java:4036)
WFCA OUT:      at com.evermind.server.administration.DefaultApplicationAdministrator.installDataSource(DefaultApplicationAdministrator.java:1809)
WFCA OUT:      at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
WFCA OUT:      at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39)
WFCA OUT:      at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
WFCA OUT:      at java.lang.reflect.Method.invoke(Method.java:585)
WFCA OUT:      at com.evermind.server.rmi.RmiMethodCall.run(RmiMethodCall.java:53)
WFCA OUT:      at com.evermind.util.ReleasableResourcePooledExecutor$MyWorker.run(ReleasableResourcePooledExecutor.java:303)
WFCA OUT:      at java.lang.Thread.run(Thread.java:595)
WFCA OUT: Error: Unable to install datasource: Cannot create connection pool. A connection pool named 'jdbc/WorkflowDS_connectionPool' already exists.
WorkflowCA: Exit Val: 1
WorkflowCA: Created a redirected data source with application WFMLRSVCApp :
WorkflowCA: Executing: /oracle/product/11.2.0/dbhome_1/jdk/bin/java -Djava.security.properties=/oracle/product/11.2.0/dbhome_1/oc4j/j2ee/home/config/jazn.security.props -Doracle.security.jazn.config=/oracle/product/11.2.0/dbhome_1/oc4j/j2ee/OC4J_Workflow_Component_Container/config/jazn.xml -jar /oracle/product/11.2.0/dbhome_1/oc4j/j2ee/home/jazn.jar -user oc4jadmin -password welcome -adduser jazn.com pwForOwfMgr <WFCA WF PASSWORD>
The specified user already exists in the system.
WorkflowCA: Created obfusticated password for redirect datasource:
WorkflowCA: Executing: /oracle/product/11.2.0/dbhome_1/jdk/bin/java -jar /oracle/product/11.2.0/dbhome_1/oc4j/j2ee/home/admin.jar ormi://jie-rhel:6041 oc4jadmin welcome -shutdown
WorkflowCA: Executed OC4J Admin script to shut down the OC4J instance :
WorkflowCA: Wed Apr 28 23:33:10 EDT 2010
WorkflowCA: Workflow Configuration has completed with error.
WorkflowCA: Terminating...

Undeploy workflow Components ( Notification Mailer and Agent Listenrs ) from OC4J. Once undeployed, you can re-run WFCA.
$ORACLE_HOME/jdk/bin/java -classpath $ORACLE_HOME/oc4j/j2ee/home/oc4j.jar:$ORACLE_HOME/jlib/srvm.jar:$ORACLE_HOME/oc4j/j2ee/home/db_oc4j_deploy.jar oracle.j2ee.tools.deploy.DbOc4jDeploy -oraclehome $ORACLE_HOME -inifile $ORACLE_HOME/oc4j/j2ee/deploy_db_wf.ini
Like oracle.j2ee.tools.deploy.DbOc4jDeploy , there should be abother utility to undeploy, I don't remeber right now, to undeply the deplyed applications.
One more ugly alternative is that :
remove oc4j/j2ee/OC4J_Workflow_Component_Container/application-deployments/WFMLRSVCApp/dta-sources.xml file manually. follow same for other components in oc4j/j2ee/OC4J_Workflow_Component_Container/application-deployments/ folder
Thanks
Shiv

Similar Messages

  • Workflow Manager 1.0 - We're sorry the product failed to install

    I know the title is the same as a previous post, but that was over a year ago and my issue was not in any of the replies.
    I have a development SharePoint 2013 system running on a VM of Windows Server 2012 R2.  SQL Server 2012 R2 Enterprise is also installed on the same VM.  Has 30GB of free disk space and 12GB RAM.  This VM is NOT a DC but is patched with all
    the latest updates.
    Each time I download and run the Web PI and Add WorkFlow Manager 1.0, it appears to install, then I get the message:
    We're Sorry.  The following products have failed to install.
    Windows Manager Client 1.0 Refresh
    This product did not download successfully:  An exception occurred during the WebClient request.
    Microsoft Windows Fabric V1 RTM
    This product did not download successfully:  An exception occurred during the WebClient request.
    Service Bus 1.0
    This product cannot be installed because a product that it depends on did not install successfully.
    Workflow Manager 1.0
    This product cannot be installed because a product that it depends on did not install successfully.
    The following products were successfully installed.
    Execute ASP.NET IIS registration tool
    I have attempted several times and different ways, but it will not install. Even tried the Offline installation as well with no success.
    Any suggestions?

    Hi,
    For CU there are Prerequisites, please check the following requirements:
    Software requirements:
    PowerShell 3.0 must be installed on the computer to be updated. PowerShell 3.0 is included in the Windows Management Framework 3.0 installation. Go to Windows Management Framework 3.0 to install this update.
    Workflow Manager Client 1.0 must be installed on the computer.
    For computers that have Workflow Manager 1.0 installed, the following additional requirements apply:
    The Service Bus for Windows Server cumulative update must be installed on the whole computer farm before you install the cumulative update for Workflow Manager 1.0
    also Service Bus for Windows Server must be installed on the computer.
    You must have administrative credentials on the computer where you are installing the software.
    Best Regards,
    Lisa Chen
    TechNet Community Support
    Please remember to mark the replies as answers if they help, and unmark the answers if they provide no help. If you have feedback for TechNet Support, contact
    [email protected]

  • Install workflow manager using DSC powershell

    Hi,
    i am trying to install workflow manager using DSC powershell.
    I am using WebpiCmd.exe to install it.
    Below is the DSC powershell script
    configuration C_WFMgr
        Node $AllNodes.NodeName
            Script WF_Install
                GetScript = { @{ Name = "WF_Install" } }
                TestScript = {                
                    $false
                SetScript =
                $currentPrincipal = New-Object Security.Principal.WindowsPrincipal( [Security.Principal.WindowsIdentity]::GetCurrent() )
                if ($currentPrincipal.IsInRole( [Security.Principal.WindowsBuiltInRole]::Administrator ) -eq $false) {
                (get-host).UI.RawUI.Backgroundcolor="DarkRed"                                   
                    write-Verbose "Warning: PowerShell is not running as an Administrator.`n"  
                    exit 
                 else
                    #set-executionpolicy "Execution user account"
                    write-Verbose $currentPrincipal.Identity.Name
                    write-Verbose "Warning: PowerShell is running as an Administrator.`n"                
                    Write-Verbose "Workflow Manager installation started.."
                    $cmd = "& 'C:\WorkflowManagerFiles\bin\WebpiCmd.exe' /Install /Products:WorkflowManager /XML:c:/WorkflowManagerFiles/feeds/latest/webproductlist.xml /log:C:/Users/backup/t1.txt
    /AcceptEula"
                    Invoke-Expression $cmd | Write-Verbose                             
    Below is the error message
    Started downloading products...
     Started installing Products...
     Started installing: 'Execute ASP.NET IIS Registration tool
     Started downloading: 'Workflow Manager Client 1.0 Refresh'
     Downloaded: 'Workflow Manager Client 1.0 Refresh'
     Started downloading: 'Service Bus 1.0'
     Downloaded: 'Service Bus 1.0'
     Started downloading: 'Workflow Manager 1.0'
     Downloaded: 'Workflow Manager 1.0'
     Install completed (Success): 'Execute ASP.NET IIS Registra
    tion tool'
     Execute ASP.NET IIS Registration tool : Installed
     Started installing: 'Workflow Manager Client 1.0 Refresh'
     Install completed (Failure): 'Workflow Manager Client 1.0
    Refresh'
     WorkflowClient : Failed.
     Error opening installation log file. Verify that the speci
    fied log file location exists and is writable.
     Started installing: 'Service Bus 1.0'
     Install completed (Failure): 'Service Bus 1.0'
     ServiceBus : Failed.
     Error opening installation log file. Verify that the speci
    fied log file location exists and is writable.
     DependencyFailed: Workflow Manager 1.0
     Verifying successful installation...
     Execute ASP.NET IIS Registration tool              True
     Workflow Manager Client 1.0 Refresh                False
         Log Location: C:\Windows\system32\config\systemprofile
    \AppData\Local\Microsoft\Web Platform Installer\logs\install\2015-01-02T14.58.57\WorkflowManagerClient_x64.txt
     Service Bus 1.0                                    False
         Log Location: C:\Windows\system32\config\systemprofile
    \AppData\Local\Microsoft\Web Platform Installer\logs\install\2015-01-02T14.58.57\Service_Bus.txt
     Workflow Manager 1.0                               False
     Install of Products: FAILURE

    I am pretty sure that DSC requires WFM.  If  I am right then WFM is in use and cannot be replaced unless you specify another logfile location.  Look at the DSC and see how to specify a new log location that can be used for the install. 
    If the MSU is built correctly then you will require a reboot to update the install.
    Try just doing WFM alone until you work it out.
    I also recommend posting in the Management forum for any other issues that might be known.
    Management
    DSC is a work in progress so many things have to be worked out as you need them.  Be sure to get the latest kits.  I think we are at Wave 9 now.
    PowerShell
    DSC Resource Kit Wave 9
    ¯\_(ツ)_/¯

  • Install workflow manager using DSC declarative configuration

    I am trying to install workflow manager using below DSC powershell script.
    Configuration
    C_Pkg_WFInstall
    Node $AllNodes.NodeName
    Package C_Pkg_WFInstall
    Ensure = "Present"
    Name = "Workflow Manager Client 1.0"
    Path = "C:\WorkflowManagerFiles\bin\WebpiCmd.exe"
    Arguments =
    "/Install /Products:'Workflow Manager Client 1.0' /XML:'c:/WorkflowManagerFiles/feeds/latest/webproductlist.xml' /log:'c:/users/backup/workflow.txt' /AcceptEula"
    ProductId =
    "A5ABAF5F-B5B6-44B3-B69F-2E13DC60FC9F"
    $ConfigData
    = @{
    AllNodes = @(
        NodeName =
    "CHN-AERO-VM28";         
    C_Pkg_WFInstall
    -ConfigurationData
    $ConfigData –Verbose
    Start-DscConfiguration
    -Wait -force
    -Verbose -Path
    .\C_Pkg_WFInstall
    And i get the below error
    PowerShell provider MSFT_PackageResource 
    failed to execute Set-TargetResource functionality with error message: The return code -1 was not expected. Configuration is likely not
    correct
    + CategoryInfo         
    : InvalidOperation: (:) [], CimException
    + FullyQualifiedErrorId : ProviderOperationExecutionFailure
    But while installing from command prompt window i could install the below list successfully
    IdentifyingNumber : {A5ABAF5F-B5B6-44B3-B69F-2E13DC60FC9F}
    Name              : Workflow Manager Client 1.0
    IdentifyingNumber : {04A7199E-565D-4654-88A3-80A9A7BADDD9}
    Name              : Workflow Manager 1.0
    IdentifyingNumber : {F438C511-5A64-433E-97EC-5E5343DA670A}
    Name              : Service Bus 1.0
    I tried with all the above 3 product ids, its not working.

    Thanks for your reply.
    I get the below error in eventviewer - Applications and Services Log - Windows Powershell
    The description for Event ID 600 from source PowerShell cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the
    local computer.
    If the event originated on another computer, the display information had to be saved with the event.
    The following information was included with the event:
    Alias
    Started
     ProviderName=Alias
     NewProviderState=Started
     SequenceNumber=1
     HostName=Default Host
     HostVersion=4.0
     HostId=979b4813-7bd4-47d7-9729-4166ae91e9c1
    The handle is invalid
    Log Name : Windows PowerShell
    Source : PowerShell (PowerShell)
    Event ID : 600
    Task Category : Provider Lifecycle
    I got the same error message in subsequent logs but the providername is different as below
     ProviderName=Environment 
     ProviderName=FileSystem  
     ProviderName=Function  
     ProviderName=Registry 
     ProviderName=Variable
    The description for Event ID 400 from source PowerShell cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local
    computer.
    If the event originated on another computer, the display information had to be saved with the event.
    The following information was included with the event:
    Available
    None
     NewEngineState=Available
     PreviousEngineState=None
     SequenceNumber=13
     HostName=Default Host
     HostVersion=4.0
     HostId=979b4813-7bd4-47d7-9729-4166ae91e9c1
     EngineVersion=4.0
     RunspaceId=6374c946-1219-4870-bc51-528faae9671d
    Log Name : Windows PowerShell
    Source : PowerShell (PowerShell)
    Event ID : 400
    Task Category : Engine Lifecycle
    But i believe the problem is with either the product name or product id, since it installs three products on one invoke, i dont know which product id we need to give. i tried with all the above 3 product ids. Its not working.
    I think by default DSC powershell runs under system account "NT AUTHORITY\SYSTEM".

  • Lightroom and acrobat pro fail to install

    I used the CCPLauncher and deployed using an .msi photoshop, dreamweaver, indesign and a few others but lightroom and acrobat pro fail to install. I recreated the packages a few times but no joy, anybody else come across this?
    Thanks

    Did you run ExceptionDeployer.exe --workflow=install --mode=pre for Acrobat and ExceptionDeployer.exe --workflow=install --mode=post for everything else?

  • 10.6.2 failed to install due to 'nfs error', audio no longer works

    macbook pro, all other updates have installed just fine, except for 10.6.2
    I get this in the log:
    11/10/09 3:58:15 PM com.apple.kextcache410 Created mkext archive //System/Library/Caches/com.apple.kext.caches/Startup/Extensions.mkext.
    11/10/09 3:58:15 PM com.apple.kextcache403 Failed to mount helper partition: error 0XF8DA000C (DA err# 0x0c).
    11/10/09 3:58:15 PM com.apple.kextd10 kextcache error while updating / (error count: 4)
    11/10/09 3:58:15 PM com.apple.kextcache403 /: trouble updating one or more helper partitions.
    11/10/09 3:58:15 PM com.apple.kextd10 async child pid 403 exited with status 70
    11/10/09 3:58:15 PM com.apple.kextd10 kextcache error while updating / (error count: 5)
    11/10/09 3:58:15 PM installd376 PackageKit: Install Failed: (null)
    Error Domain=PKInstallErrorDomain Code=121 UserInfo=0x104d22740 "An error occurred while updating system extension information." Underlying Error=(Error Domain=NSPOSIXErrorDomain Code=70 "The operation couldn’t be completed. Stale NFS file handle") {
    NSLocalizedDescription = "An error occurred while updating system extension information.";
    NSUnderlyingError = "Error Domain=NSPOSIXErrorDomain Code=70 \"The operation couldn\U2019t be completed. Stale NFS file handle\"";
    arguments = (
    "-update-volume",
    nothing is mounted (i rebooted before applying). not sure why it's giving that NFS error. it's consistent tho.. if i reboot and try the manual install of the patch, I get the same error.
    after the failed patch "installed" it left my sound not working... so far everything else appears to work. any thoughts on fixing this are appreciated. i ran diskutil and 'fixed perms' and 'verified disk' ... patch still fails.

    Try reinstalling the patch. If you get all the way through the installation, then see if your sound works. If not, then I suggest you do a repair install of Sno by installing Sno over Sno as in an upgrade install. Such an install, while usually very safe, still is an install so be appropriated backed up if you proceed.

  • Failed to install Creative Cloud desktop error code 1 Windows 8.1

    I just recently tried to begin a trial of creative cloud in order to get access to photoshop. I really need photoshop for my school because of how powerful it is and the tools is offers. A couple weeks ago I tried to download and install creative cloud for windows 8 64-bit, and the download begins, but once it reaches around 50%, it raises an error message saying "We've encountered the following issues: Creative Cloud desktop failed to install (error code 1)". I was having problems with the internet at the time so I just naturally assumed it was the cause. So I went ahead and gave it a couple of days before I tried again. When I tried again I received the same error message at the same time. I continued to look around for a solution and trying it everyday but I have had absolutely no luck with it, and honestly am getting quite frustrated with it. I have looked everywhere for a solution, I tried the adobe clenup tool, I have checked to make sure I don't have any previous versions of adobe products on my computer, and even tried installing it as an admin in safe mode, and still nothing. I have no idea what to do next, but I know that I have to get ahold of photoshop, one way or another, and it must have the professional tools included in the creative cloud edition. Please tell me there is a simple solution and I have been blind this entire time. If there is no solution, can someone direct me to another software similar to photoshop that has access to the plug-in dDo? (I am in game development and have heard how powerful dDo is and have been dying to use it. I have also been anxious to get photoshop, but it doesn't appear to be possible without the creative cloud desktop app).

    Link for Download & Install & Setup & Activation problems may help
    -Online Chat http://www.adobe.com/support/download-install/supportinfo/

  • HP C1680 fails to install Software

    Can you please help
     I have just reinstalled my operating system Windows 7 6- bit OS and needed to reinstall my printer HP Photosmart C6180 All in One. When I first got my new PC( Dell XPS 501L windows 7 Intel core i5. 243M  2.40GHz)  I originally install the whole package with no issues.
    after the reinstall of the OS, this is issue I was I getting when I tried to reinstalled the HP application (AIO_CDA_FSW_Full_Win_WW_130_140.exe )
    Error message:-
    C:\Users\andylouey\AppData\Local\Temp\7zS4864\setu​p\HPzPNP.ice.
     I have done the following:
    Tried to install from an old download of the software.  Result Failed to install message as above.
    Tried the original install CD and also tried to use them in various compatibility modes. Result Failed.
    Downloaded the critical updates from HP solved the above error message result the above error message was solved.
    Downloaded the latest install software program for my HP printer from the HP website tried again to install failed
    Ran the HP Scan doctor reported that the printer drivers are all working asked it to run the scan program it reported that it need the full install of the C1680 software to run this
    I got the download again ran it. It extracts the file then just disappears and looking at the task manager there is not install running. So again failed
    For the second time I downloaded the HP installer network printer wizard but this failed and just keeps going round in circles> It finishes the download gets to the extracting point and then goes back to the identify printer( which is listed) then goes back once again and downloads the install software.
    Other steps I have taken. I used the old installation disk to do a complete uninstall of all the drivers and software  using Utilities> CCC> Uninstall_ L2.bat . This wored and uninstalled the printer and drivers and I think any remaining software.  I also deleted all the %TEMP% files that my Laptop would allow.
    Then once again I I used the install wizard first without the USB cable disconnected then the wizard asked me to plug it in. I plugged it in and HP Wizard found the printer and downloaded the appropriate software completed the download and extracted it and then NOTHING.
    I have also downloaded the critical update:-
    http://h10025.www1.hp.com/ewfrf/wc/softwareDownloa​dIndex?softwareitem=mp-126392-2&cc=uk&dlc=en&lc=en​...
    Can you suggest a solution help. In my view I need to start from scratch and remove all traces of any HP software and drivers and start over. My only issue with this I have done this and still have the same issues.  If I go to Microsoft uninstall utility there isn’t anything to uninstall.
     Thanks in advance for your reply.
    PS. HP wizard has finished downloading for the fourth time and looping to discovering the device again :-( HELP!!!!!!!!
    Thanks in adbance for your replies Andy

    Hi
    Thank you for your reply and your advice and help
     If you look at my help request aboveI have described that I have done your suggetion and yet there are still traces of HP on my hard drive and I am still haveing the same issues.
    Below are the steps you have referred to which I covered in my original request :-
    Other steps I have taken. I used the old installation disk to do a complete uninstall of all the drivers using CCC> Utilities and Uninstall_L3 . I also deleted all the %TEMP% files  (7z) that my Laptop would allow.
    Then once again I I used the install wizard first wit the USB cable disconnected then the wizard asked me to plug it in. I plugged it in and HP Wizard found the printer and downloaded the appropriate software completed the download and extracted it and then NOTHING. Except the drivers were installed and the printer was  shown in the devices and printers.
    I have also downloaded the critical update:-
    http://h10025.www1.hp.com/ewfrf/wc/softwareDownloa​dIndex?softwareitem=mp-126392-2&cc=uk&dlc=en&lc=en​...
    Can you suggest a solution help. In my view I need to start from scratch and remove all traces of any HP software and drivers and start over. My only issue with this I have done this and still have the same issues. If I go to Microsoft uninstall utility there isn’t anything to uninstall.
    I can print to the printer both wirelessly and via the USB port. But the Solution center will not install just keeps looping. ie idenifies the printer downloads the latest sofware and extracts it then just dissapears of the screen. Nothing comes up and there are no HP programs running in the applications task manager and no processes either.
    Thank you in advance for your reply. Regards Andy

  • Kb2920189 fails to install on Windows 2012 R2 Essentials

    Hello,
    I have a 2012 R2 Essentials server that fails to install the UEFI KB2920189 update.  All other updates installed fine.  It's running two disks, one has 8.1 the other has 2012 R2 Esssentials in dual boot mode.  No VM.  I have heard reports
    of successful installs of this kb2920189 update that basically bricks the OS on reboot.  I would like to avoid this.  The error code during the failed installation is 800F0922.
    Thanks

    Hi,
    Based on your description, I understand that you failed to install KB2920189 with error 800F0922.
    Please refer to following operations and check if can help you to solve this issue.
    Refer to the KB (KB947821), and use the inbox Deployment Image Servicing and Management (DISM) tool. Then install
    this update again.
    Please
    reset Windows Update components and monitor the result.
    Please perform a
    clean boot and check if you can install this update successfully.
    If this issue still persists, please navigate to: %windir%\Windowsupdate.log and check the log file if can
    find some more clues.
    For more details, please refer to the following KB.
    How to read the Windowsupdate.log file
    Hope this helps.
    Best regards,
    Justin Gu

  • Fail to install Distibution Point on Windows Server 2012

    I have been trying to install a distribution point via sccm 2012 on a windows 2012 server. I keep getting errors about the drive not found (distribution manager failed to verify drive specified by user on distribution point) and it won't install. It worked
    on all the other servers I tried, but this one keeps giving trouble.
    Does anyone have any idea as to the cause?
    I put an extract of the log file here:
    Get site system FQDN and account information from DB for ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\ SMS_DISTRIBUTION_MANAGER 31/12/2013 13:56:18 5848 (0x16D8)
    Get site system FQDN and account information from DB for ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\ SMS_DISTRIBUTION_MANAGER 31/12/2013 13:56:19 5848 (0x16D8)
    Failed to get SMS_DistributionPoint object SMS_DISTRIBUTION_MANAGER 31/12/2013 13:56:20 5848 (0x16D8)
    DPConnection::Connect: For ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\, logged-on as SESVANDERHAVE\svc_scom_msaa SMS_DISTRIBUTION_MANAGER 31/12/2013 13:56:32 3724 (0x0E8C)
    ConfigureDP SMS_DISTRIBUTION_MANAGER 31/12/2013 13:56:32 3724 (0x0E8C)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 31/12/2013 13:56:44 1724 (0x06BC)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 31/12/2013 13:56:49 1724 (0x06BC)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 31/12/2013 13:56:54 1724 (0x06BC)
    DP registry settings have been successfully updated on HUSOWINFP01.sesvanderhave.net SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:05 3724 (0x0E8C)
    STATMSG: ID=9500 SEV=I LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=8216 TID=3724 GMTDATE=di dec 31 12:57:05.905 2013 ISTR0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\"
    ISTR1="" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=404 AVAL0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\" SMS_DISTRIBUTION_MANAGER 31/12/2013
    13:57:05 3724 (0x0E8C)
    STATMSG: ID=9503 SEV=I LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=8216 TID=3724 GMTDATE=di dec 31 12:57:05.905 2013 ISTR0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\"
    ISTR1="" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=404 AVAL0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\" SMS_DISTRIBUTION_MANAGER 31/12/2013
    13:57:05 3724 (0x0E8C)
    ConfigurePXE SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:05 3724 (0x0E8C)
    Failed to get SMS_DistributionPoint object SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:07 3724 (0x0E8C)
    CDistributionManager::ConfigurePXE failed; 0x80041002 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:07 3724 (0x0E8C)
    No need to initialize monitoring task on HUSOWINFP01.sesvanderhave.net SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:16 3724 (0x0E8C)
    Creating, reading or updating IIS registry key for a distribution point. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:18 5848 (0x16D8)
    IISPortsList in the SCF is "80". SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:18 5848 (0x16D8)
    IISSSLPortsList in the SCF is "443". SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:18 5848 (0x16D8)
    IISWebSiteName in the SCF is "". SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:18 5848 (0x16D8)
    IISSSLState in the SCF is 224. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:18 5848 (0x16D8)
    DP settings have been updated to HUSOWINFP01.sesvanderhave.net. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:21 3724 (0x0E8C)
    DPConnection::Disconnect: Revert to self SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:22 3724 (0x0E8C)
    Sleep 1231 seconds... SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:22 3724 (0x0E8C)
    Failed to get SMS_DistributionPoint object SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:22 5848 (0x16D8)
    Found notification for package 'SES00003' SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:32 3724 (0x0E8C)
    Found notification for package 'SES00004' SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:32 3724 (0x0E8C)
    Package Thread Limit: 3 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:32 3724 (0x0E8C)
    Retry interval: 30 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:32 3724 (0x0E8C)
    DP upgrade thread Limit: 5 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:32 3724 (0x0E8C)
    DP upgrade retry interval: 20 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:32 3724 (0x0E8C)
    Used 0 out of 3 allowed processing threads. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:32 3724 (0x0E8C)
    Starting package processing thread, thread ID = 0x2274 (8820) SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:32 3724 (0x0E8C)
    Starting package processing thread, thread ID = 0x9B8 (2488) SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:33 3724 (0x0E8C)
    Sleep 3600 seconds... SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:33 3724 (0x0E8C)
    STATMSG: ID=2304 SEV=I LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=8216 TID=8820 GMTDATE=di dec 31 12:57:33.112 2013 ISTR0="SES00003" ISTR1="" ISTR2=""
    ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=400 AVAL0="SES00003" SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:33 8820 (0x2274)
    Retrying package SES00003 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:33 8820 (0x2274)
    No action specified for the package SES00003. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:33 8820 (0x2274)
    STATMSG: ID=2304 SEV=I LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=8216 TID=2488 GMTDATE=di dec 31 12:57:33.112 2013 ISTR0="SES00004" ISTR1="" ISTR2=""
    ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=400 AVAL0="SES00004" SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:33 2488 (0x09B8)
    Retrying package SES00004 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:33 2488 (0x09B8)
    No action specified for the package SES00004. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:33 2488 (0x09B8)
    Start adding package to server ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\... SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 8820 (0x2274)
    Start adding package to server ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\... SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 2488 (0x09B8)
    Attempting to add or update a package on a distribution point. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 7936 (0x1F00)
    Attempting to add or update a package on a distribution point. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 3404 (0x0D4C)
    The distribution point ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\ is not installed or upgraded yet. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 7936 (0x1F00)
    Error occurred. Performing error cleanup prior to returning. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 7936 (0x1F00)
    The distribution point ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\ is not installed or upgraded yet. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 3404 (0x0D4C)
    Error occurred. Performing error cleanup prior to returning. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 3404 (0x0D4C)
    Will wait for 1 threads to end. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 8820 (0x2274)
    Thread Handle = 00000000000031DC SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 8820 (0x2274)
    DP thread with array index 0 ended. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 8820 (0x2274)
    DP thread with thread handle 00000000000031DC and thread ID 7936 ended. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 8820 (0x2274)
    Will wait for 1 threads to end. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 2488 (0x09B8)
    Thread Handle = 00000000000016A8 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 2488 (0x09B8)
    DP thread with array index 0 ended. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 2488 (0x09B8)
    DP thread with thread handle 00000000000016A8 and thread ID 3404 ended. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:35 2488 (0x09B8)
    Package SES00003 does not have a preferred sender. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 8820 (0x2274)
    The package and/or program properties for package SES00003 have not changed,  need to determine which site(s) need updated package info. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 8820 (0x2274)
    CDistributionSrcSQL::UpdateAvailableVersion PackageID=SES00003, Version=1, Status=2301 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 8820 (0x2274)
    Package SES00004 does not have a preferred sender. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 2488 (0x09B8)
    The package and/or program properties for package SES00004 have not changed,  need to determine which site(s) need updated package info. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 2488 (0x09B8)
    CDistributionSrcSQL::UpdateAvailableVersion PackageID=SES00004, Version=1, Status=2301 SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 2488 (0x09B8)
    StoredPkgVersion (1) of package SES00003. StoredPkgVersion in database is 1. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 8820 (0x2274)
    SourceVersion (1) of package SES00003. SourceVersion in database is 1. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 8820 (0x2274)
    STATMSG: ID=2302 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=8216 TID=8820 GMTDATE=di dec 31 12:57:36.247 2013 ISTR0="Configuration Manager Client Package" ISTR1="SES00003"
    ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=400 AVAL0="SES00003" SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 8820
    (0x2274)
    Failed to process package SES00003 after 1 retries, will retry 99 more times SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 8820 (0x2274)
    Exiting package processing thread. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 8820 (0x2274)
    StoredPkgVersion (1) of package SES00004. StoredPkgVersion in database is 1. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 2488 (0x09B8)
    SourceVersion (1) of package SES00004. SourceVersion in database is 1. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 2488 (0x09B8)
    STATMSG: ID=2302 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=8216 TID=2488 GMTDATE=di dec 31 12:57:36.282 2013 ISTR0="Configuration Manager Client Upgrade Package"
    ISTR1="SES00004" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=400 AVAL0="SES00004" SMS_DISTRIBUTION_MANAGER 31/12/2013
    13:57:36 2488 (0x09B8)
    Failed to process package SES00004 after 1 retries, will retry 99 more times SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 2488 (0x09B8)
    Exiting package processing thread. SMS_DISTRIBUTION_MANAGER 31/12/2013 13:57:36 2488 (0x09B8)

    I uninstalled the WDS according to the information on this site: http://myitforum.com/myitforumwp/2011/11/08/configmgr-2012-no-need-to-manually-install-wds/
    But it still keeps giving me errors about the disk not being valid, it does that wether I choose a disk or leave the default values.
    DPConnection::Connect: For ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\, logged-on as SESVANDERHAVE\svc_scom_msaa SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:33 2964 (0x0B94)
    ConfigureDP SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:33 2964 (0x0B94)
    Upgrading DP with ID 16777238. Thread 0x1bdc. Used 1 threads out of 5. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:50 7492 (0x1D44)
    Processing 16777238.INS SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:50 7132 (0x1BDC)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:50 7492 (0x1D44)
    DPID 16777238 - NAL Path ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\ , ServerName = HUSOWINFP01.SESVANDERHAVE.NET, DPDrive = D:, IsMulticast = 0, PXE = 1, RemoveWDS = 0 SMS_DISTRIBUTION_MANAGER 6/01/2014
    8:49:50 7132 (0x1BDC)
    Created policy provider trigger for ID 16777238 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:50 7692 (0x1E0C)
    DPConnection::Connect: For ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\, logged-on as SESVANDERHAVE\******** SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:54 7132 (0x1BDC)
    Failed to find a valid drive on the distribution point ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\ SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:55 7132 (0x1BDC)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:55 7492 (0x1D44)
    DPConnection::Disconnect: Revert to self SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:56 7132 (0x1BDC)
    Failed to install DP files on the remote DP. Error code = 15 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:56 7132 (0x1BDC)
    Drive D: is not valid. Error = 15 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:56 7132 (0x1BDC)
    STATMSG: ID=2360 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=4552 TID=7132 GMTDATE=ma jan 06 07:49:56.907 2014 ISTR0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\"
    ISTR1="HUSOWINFP01.SESVANDERHAVE.NET" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=404 AVAL0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\" SMS_DISTRIBUTION_MANAGER 6/01/2014
    8:49:56 7132 (0x1BDC)
    Will try again after 20 mins ... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:56 7132 (0x1BDC)
    DP registry settings have been successfully updated on HUSOWINFP01.sesvanderhave.net SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:58 2964 (0x0B94)
    STATMSG: ID=9500 SEV=I LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=4552 TID=2964 GMTDATE=ma jan 06 07:49:58.295 2014 ISTR0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\"
    ISTR1="" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=404 AVAL0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\" SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:58 2964
    (0x0B94)
    STATMSG: ID=9503 SEV=I LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=4552 TID=2964 GMTDATE=ma jan 06 07:49:58.295 2014 ISTR0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\"
    ISTR1="" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=404 AVAL0="["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\" SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:58 2964
    (0x0B94)
    ConfigurePXE SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:58 2964 (0x0B94)
    Failed to get SMS_DistributionPoint object SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:58 2964 (0x0B94)
    CDistributionManager::ConfigurePXE failed; 0x80041002 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:49:58 2964 (0x0B94)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:00 7492 (0x1D44)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:05 7492 (0x1D44)
    Initialize monitoring task on HUSOWINFP01.sesvanderhave.net SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:16 2964 (0x0B94)
    Failed to get object class SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:16 2964 (0x0B94)
    ExecStaticMethod failed (80041002) SMS_DistributionPoint, RegisterDPHealthMonTask SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:16 2964 (0x0B94)
    Failed to register DP health monitoring task on HUSOWINFP01.sesvanderhave.net. error = 0x80041002 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:16 2964 (0x0B94)
    DP settings have been updated to HUSOWINFP01.sesvanderhave.net. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:21 2964 (0x0B94)
    DPConnection::Disconnect: Revert to self SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:21 2964 (0x0B94)
    Sleep 60 seconds... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:21 2964 (0x0B94)
    Found notification for package 'SES00003' SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:31 2964 (0x0B94)
    Found notification for package 'SES00004' SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:31 2964 (0x0B94)
    Package Thread Limit: 3 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:31 2964 (0x0B94)
    Retry interval: 30 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:31 2964 (0x0B94)
    DP upgrade thread Limit: 5 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:31 2964 (0x0B94)
    DP upgrade retry interval: 20 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:31 2964 (0x0B94)
    Used 0 out of 3 allowed processing threads. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:31 2964 (0x0B94)
    Starting package processing thread, thread ID = 0x12CC (4812) SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:31 2964 (0x0B94)
    Starting package processing thread, thread ID = 0xDD8 (3544) SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:32 2964 (0x0B94)
    Sleep 3600 seconds... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:32 2964 (0x0B94)
    STATMSG: ID=2304 SEV=I LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=4552 TID=4812 GMTDATE=ma jan 06 07:50:32.429 2014 ISTR0="SES00003" ISTR1="" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7=""
    ISTR8="" ISTR9="" NUMATTRS=1 AID0=400 AVAL0="SES00003" SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:32 4812 (0x12CC)
    Retrying package SES00003 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:32 4812 (0x12CC)
    No action specified for the package SES00003. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:32 4812 (0x12CC)
    STATMSG: ID=2304 SEV=I LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=4552 TID=3544 GMTDATE=ma jan 06 07:50:32.475 2014 ISTR0="SES00004" ISTR1="" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7=""
    ISTR8="" ISTR9="" NUMATTRS=1 AID0=400 AVAL0="SES00004" SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:32 3544 (0x0DD8)
    Retrying package SES00004 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:32 3544 (0x0DD8)
    No action specified for the package SES00004. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:32 3544 (0x0DD8)
    Start adding package to server ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:34 4812 (0x12CC)
    Attempting to add or update a package on a distribution point. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:34 8896 (0x22C0)
    The distribution point ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\ is not installed or upgraded yet. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:34 8896 (0x22C0)
    Error occurred. Performing error cleanup prior to returning. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:34 8896 (0x22C0)
    Start adding package to server ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:34 3544 (0x0DD8)
    Attempting to add or update a package on a distribution point. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:34 4628 (0x1214)
    The distribution point ["Display=\\HUSOWINFP01.sesvanderhave.net\"]MSWNET:["SMS_SITE=SES"]\\HUSOWINFP01.sesvanderhave.net\ is not installed or upgraded yet. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:34 4628 (0x1214)
    Error occurred. Performing error cleanup prior to returning. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:34 4628 (0x1214)
    Will wait for 1 threads to end. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    Thread Handle = 0000000000002BE0 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    DP thread with array index 0 ended. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    DP thread with thread handle 0000000000002BE0 and thread ID 8896 ended. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    Will wait for 1 threads to end. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    Thread Handle = 0000000000002CF0 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    DP thread with array index 0 ended. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    DP thread with thread handle 0000000000002CF0 and thread ID 4628 ended. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    Package SES00004 does not have a preferred sender. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    The package and/or program properties for package SES00004 have not changed,  need to determine which site(s) need updated package info. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    CDistributionSrcSQL::UpdateAvailableVersion PackageID=SES00004, Version=1, Status=2301 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    Package SES00003 does not have a preferred sender. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    The package and/or program properties for package SES00003 have not changed,  need to determine which site(s) need updated package info. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    CDistributionSrcSQL::UpdateAvailableVersion PackageID=SES00003, Version=1, Status=2301 SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    StoredPkgVersion (1) of package SES00004. StoredPkgVersion in database is 1. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    SourceVersion (1) of package SES00004. SourceVersion in database is 1. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    STATMSG: ID=2302 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=4552 TID=3544 GMTDATE=ma jan 06 07:50:35.736 2014 ISTR0="Configuration Manager Client Upgrade Package" ISTR1="SES00004" ISTR2=""
    ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=400 AVAL0="SES00004" SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    Failed to process package SES00004 after 77 retries, will retry 23 more times SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    Exiting package processing thread. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 3544 (0x0DD8)
    StoredPkgVersion (1) of package SES00003. StoredPkgVersion in database is 1. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    SourceVersion (1) of package SES00003. SourceVersion in database is 1. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    STATMSG: ID=2302 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_DISTRIBUTION_MANAGER" SYS=BEHQWINSCCM02.sesvanderhave.net SITE=SES PID=4552 TID=4812 GMTDATE=ma jan 06 07:50:35.829 2014 ISTR0="Configuration Manager Client Package" ISTR1="SES00003" ISTR2="" ISTR3=""
    ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=1 AID0=400 AVAL0="SES00003" SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    Failed to process package SES00003 after 77 retries, will retry 23 more times SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    Exiting package processing thread. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:35 4812 (0x12CC)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:36 7492 (0x1D44)
    Used 0 out of 3 allowed processing threads. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:37 2964 (0x0B94)
    Sleep 1828 seconds... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:37 2964 (0x0B94)
    Sleep 20 minutes... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:41 7492 (0x1D44)
    Used 0 out of 3 allowed processing threads. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:42 2964 (0x0B94)
    Sleep 1823 seconds... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:42 2964 (0x0B94)
    Used 0 out of 3 allowed processing threads. SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:47 2964 (0x0B94)
    Sleep 1818 seconds... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:47 2964 (0x0B94)
    Sleep 1818 seconds... SMS_DISTRIBUTION_MANAGER 6/01/2014 8:50:47 2964 (0x0B94)

  • Install of CUCM 8.6.1.10000-43 on VMWare fails on installing progmeter

    Hi, Everyone
    First time post here, and first time installing CUCM (any version).
    I built a VM using a downloaded OVA template for CUCM 6.5.1.10000-43, and the install fails with a critical stop.  Once I figured out how to dump logs to the virtual serial port, and looked at the install.log, I found the following information that looks like where the install failed (these are the only LVL::Error and LVL::Critical messages in the log).
    It looks like install failed to install the progmeter application component.
    Does anyone know what this app does?  Any ideas on why it might have failed to install and possible workaround?
    I may already have the answer to the question, as I'm attempting install on a VM running on VMWare vServer (rather than ESX/ESXi/vSphere).  It is possible that simply being on an unsupported configuration is my problem.  I'm trying to work with the equipment immediately available to me, but fully understand that I may have set myself up for failure by even attempting this.
    Any help is appreciated greatly.
    Regards,
    Sean C
    INSTALL LOG SNIPPET
    08/17/2011 17:51:51 component_install|File:/opt/cisco/install/bin/component_install:743, Function: exec_progmeter(), /opt/cisco/install/bin/progmeter failed (1)|<LVL::Error>
    08/17/2011 17:51:51 appmanager.sh|Internal Error, File:/usr/local/bin/base_scripts/appmanager.sh:155, Function: install(), failed to install application components|<LVL::Critical>
    08/17/2011 17:51:51 post_install|File:/opt/cisco/install/bin/post_install:869, Function: install_applications(), /usr/local/bin/base_scripts/appmanager.sh -install failed (1)|<LVL::Error>
    08/17/2011 17:51:51 post_install|Exiting with result 1|<LVL::Info>
    08/17/2011 17:51:51 post_install|INSTALL_TYPE="Basic Install"|<LVL::Debug>
    08/17/2011 17:51:51 post_install|File:/opt/cisco/install/bin/post_install:570, Function: check_for_critical_error(), check_for_critical_error, found /common/log/install/critical.log, exiting|<LVL::Error>
    08/17/2011 17:51:52 post_install|(CAPTURE) Mail notification cancelled - smtp server address for email not found! [/usr/local/platform/conf/platformConfig.xml]|<LVL::Debug>
    08/17/2011 17:51:52 display_screen|Arguments: "Critical Error" "The installation has encountered a unrecoverable internal error. For further assistance report the following information to your support provider.
    "/opt/cisco/install/callmanager/scripts/cm_msa_post.sh install PostInstall 8.6.1.10000-43 8.6.1.10000-43 /usr/local/cm/ /usr/local/cm/ /common/log/install/capture.txt " terminated. Exceeded max time (360)
    The system will now halt.
    Continuing will allow you to dump diagnostic information before halting." "Continue"|<LVL::Debug>

    Hi,
    Has anyone found a fix for this?
    I am trying to run call manager 8.6.1 on the following enviroment
    VMware ESXI 4.1
    4GB of RAM
    80 GB HDD Space
    I have allocated the VM one CPU
    In regards to vsergeyey reponse I have checked the network adapter and this is flexible.
    I have run the OVA template firstly before mounting the image
    I have tried installing numerous times.
    Each and every time near the "Installing Database Component" I get the following error;

  • After an iTunes update failed to install iTunes won't open and I get lthe folloowing error messages.  Program can't start because MSVCR80.dll is missing, and iTunes not installed correctly. please reinstall iTunes. Error 7( windows errpr 126)

    After an iTunes update failed to install, iTunes won't open and I get the following two windows.  Program can't start because MSVCR80.dll is missing from your computer, and iTunes not installed correctly. Please reinstall iTunes. Error 7 (windows error 126)  When I reinstall I get the same messages and ITunes won't open.

    Click here and follow the instructions.
    (98815)

  • Snow Leopard fails to install - Tech Support and Genius Bar can't fix it

    I am having an exceedingly difficult time installing Snow Leopard. I have tried everything I can think of and tech support AND the Genius Bar have failed me so far.
    The Details:
    Every time I install SL it starts off well but sometime between 18 minutes remaining and 6 minutes remaining it fails. I get an error message that says there was an error that prevented installation. Looking in the installer log gives me a little more information. It usually has 15 or so errors, the last of which is always a very long line saying some package failed to install/unpack/be copied. The odd thing is that the file name is different every time.
    So far I have tried:
    Repairing the disk and installing
    Installing from a different install DVD
    Installing from external hard drive at the Genius Bar
    Installing using RAM borrowed from the Genius Bar
    Wiping the HD completely. I erased all my partitions and tried to install on a completely blank hard drive with a single HFS+ partition
    I can only think of a few things that can cause the install to fail: DVD, optical drive, RAM, files on HDD, and HDD hardware. I think I've eliminated all those possibilities except HDD hardware. Changing that on a MacBook isn't trivial and I don't have one handy. Also I would think a HDD problem, or any hardware problem, would cause all sorts of errors and with the exception of this the machine has no serious problems and apps crash only occasionally. I've had no system crashes for as long as I can remember.
    I have a Time Machine back up and have successfully restored my old Leopard System onto the MacBook (twice now) so at least I have the option to just give up on SL if I want to. As an aside, restoring from TM went well but not perfectly. Next time I install an OS I will be making a disk image backup. Does anyone else have any ideas? If you solve this problem I'll be eternally grateful and very impressed.
    Thanks in advance
    Jay

    I'm sorry. I should have answered when you asked about RAM the first time. I have 2GB. I have tried installing with that, and I tried installing with RAM at the Genius Bar. I don't know how much the guy used at the Genius Bar.
    Last night I restored from time machine so I currently have Leopard installed on the machine. After the restoration my email archive is little strange, I had to re-authorize iTunes and various other annoyances pop up but it runs without any problems.

  • TS1702 I have just tried to install Anthill to my iPod touch Gen 4. I get a message "Anthill failed to install" on the iPod. I already had Anthill Free installed so deleted it. I can install other free apps but not Anthill Free. Have tried the 7 steps. An

    I have just tried to install the full version of Anthill to my iPod touch Gen 4.  I get a message on the iPod saying "Anthill failed to install" and an error on the computer "OxE8000004".  I already had Anthill Free installed so deleted it in case it was interferring with the new download.  I can install other free apps but now can't even install Anthill Free.  I have tried the 7 resolution steps advised by Apple and have totally run out of ideas as to what I can try next.  I am using a new laptop since installing Anthill Free the first time and am now running Windows 7, otherwise everything else is the same.  Any help would be sincerely appreciated.  Thanks.

    - Maybe here:
    iPhone, iPad, iPod touch: Unknown error containing '0xE' when connecting
    - Try redownloading the app directly to the iPod by:
    Downloading past purchases from the App Store, iBookstore, and iTunes Store

  • Hi, I recently upgraded my xcode to 5.1, my project is running well in ios 7.0,6.0, But in ios 7.1 i'm getting error like"iOS Simulator failed to install the application". Can anybody please suggest the solution for it.

    My project is not running in ios 7.1 simulator i'm getting error like "iOS Simulator failed to install the application". Please suggest a solution for it.

    We aren't Apple, just users like you. Have you tried a reset? Hold down the home button along with the sleep/wake button until the screen goes black and you see the Apple, then let go. (No data loss)

Maybe you are looking for

  • Controlling output video bit rate in FCPX

    I ran into a problem: I created a mp4 file with Share/Export File- (settings: Computer, H.264 Faster Encode, 1920x1080 - edited from an HD camera): its video always freezes at a definite point when played on my BD Player connected to my HDTV through

  • Difference: SAP BW Report iview - Query iView - URL iView

    Hi, I want to show BW reports on the portal. Can anybody suggest me the different ways of doing it ? And also let me know about checklist of steps that need to be performed. Can anybody tell me the difference between showing BW reports through URL iv

  • ALSB 3.0:  Unable to retrieve files from Novell FTP Server

    I have written several ALSB proxy services that retrieve data from Unix FTP servers. This works great and I haven't experienced any major issues. However, I now have to write a service that monitors a directory on a Novell FTP server. The same exact

  • SQ01 - Additional fields

    Hi friends, I generated new infotipo for personnel evaluation. Now when new infotipo i want to use it in trx. SQ01 to do query, the additional fields, are not seen. They are fields with description texts. How I can see those fields of infotipo?. Than

  • Stop alt from shifting focus to the menu?

    Hi, Every time I press Alt the focus shifts to the menu bar, just as it does with other windows programs. This means I have to escape the menu every time I zoom, which is time consuming and extremely irritating. Does anyone know how to stop this beha