Faxing via SMTP using Faxination 5 as the Fax Server
Hi,
I need to setup faxing from a ECC6 server using a Faxination 5 server. Currently we have it setup OK using a 4.6C server but ECC6 doesn't work.....so I am looking for a work around.....this is were I hope you guys can help
I was thinking of setting up Faxing via SMTP (using MS Exchange) and the Faxination 5 server, has anyone done this? Or know if it can be done using Faxination?
Faxing is possible from Exchange using a Faxination Exchange connector and I have looked at the thread Extraneous "FAX=+" prefix when sending faxes via SMTP and it would appear that other people have set this up using different Fax software. Does anyone know what format the fax server will be looking for?
Many thanks
Rob
Hello,
Basically the RFC interface of SAPConnect has not been changed, so your FAXServer should be able to handle RFC Faxing also in ECC6 Server.
You can recheck the configuration. /* Or copy here the error message, so we can take a look at */
The output formats can be set-up in the SAP System also for SMTP Faxing.
I think the destionation format should only depend on your Fax server needs.
Best regards,
Dezso
Similar Messages
-
Is it possible to use some product on the unix server at the development level which would make it p
Hello,
We are generating editable PDF forms from the scratch at the development level on the unix server. Is it possible to use some product on the unix server at the development level which would make it possible to save these editable PDF forms to be saved using acrobat reader? These forms are used by the end users and the edited files are then saved... Kindly help me in this regard..
Best Regards,
DeepakDear Aandi,
I am really thankful to you for this. I will suggest this to the business and then they can contact adobe for this. Thanking you once again for providing me with all the valueable info. You have been instrumental in helping me out in my project.
Best Regards,
Deepak Goyal -
How to configure router to use ip pool on the aaa server for vpn clients
how to configure router to use ip pool on the aaa server for vpn clients . i want to use vpn clients to connect to the router. authenticate using the aaa server username databse and also use the ip pool cretaed on the aaa server. i am not able to find the command on the router pointing to use the pool created on the aaa server. can u some one help me with this command.
sebastanHello Sebastan,
what do you use as AAA server (e.g. ACS with TACACS+ or RADIUS) ?
Regards,
GNT -
Our company recently moved to Office 365 which mean our on premise exchange server went away as well with the move. I am trying to configure my new sql server (OS-Windows Server 2012 R2, DBMS- SQL 2014 Std Edtion). After some searching I found
this article (http://blogs.technet.com/b/meamcs/archive/2013/02/25/how-to-configure-sql-database-mail-so-send-emails-using-office-365-exchange-online-a-walkthrough.aspx) and have followed these steps exactly, but to no avail. I did some further research
on the SMTP relay I setup and found a way to test it (listed here http://technet.microsoft.com/en-us/library/dn592151(v=exchg.150).aspx at the bottom of the article). If I drop the email.txt file in the pickup folder, it gets sent out no problem.
I have configured my db email exactly as describe here(http://blogs.technet.com/b/meamcs/archive/2013/02/25/how-to-configure-sql-database-mail-so-send-emails-using-office-365-exchange-online-a-walkthrough.aspx). But keep getting an unable to connect
to SMTP server error. I have even tried completely shutting down firewall to see if that is the issue and multiple restarts. Any ideas how to get this to work on Office 365?
DB Mail error log:
Date 6/10/2014 10:28:41 PM
Log Database Mail (Database Mail Log)
Log ID 46
Process ID 2196
Mail Item ID 19
Last Modified 6/10/2014 10:28:41 PM
Last Modified By xx
Message
The mail could not be sent to the recipients because of the mail server failure. (Sending Mail using Account 2 (2014-06-10T22:28:41). Exception Message: Cannot send mails to mail server. (Failure sending mail.).Hi,
I followed this blog and got the below error message in the Database Mail Log.
“The mail could not be sent to the recipients because of the mail server failure. (Sending Mail using Account 2 (2014-06-11T19:34:00). Exception Message: Cannot send mails to mail server. (Mailbox unavailable. The server response was: 5.7.1 Unable to relay
for [email protected]).”
If you are getting the same error message, you can try the below steps to resolve the issue.
1. Open the IIS 6.0 management console. Right click on the SMTP server and open the properties window.
2. Click on the Access tab, click Relay button under Relay restrictions. loopback IP address (i.e 127.0.0.1).
Then the email should be sent out from Database Mail without problem.
Thanks.
Tracy Cai
TechNet Community Support -
How to set a different smtp in and out on the same server
Hello,
I got an xserve on 10.5.6 and the ethernet ports are connected to two differents networks. One is on the local network (192.168.0.5) and the other on a wan. The lan is on ADSL box that is also the router. I would like to receive my email from the adsl box (it work like this actualy - smtp in) but sent the mails from my user with the wan (smtp out). I did'nt find any setting on the admin server graphic interface and Apple confirms that it is not possible without modifing files with the terminal. (they did'nt give the solution:()
Is anyone can help me to make this configuration work.
Thanks in advance.Short answer: you can't - at least not directly.
What you're trying to do breaks the fundamental rules of IP routing - specifically you can only have one default route that's used for all non-local traffic. That route will either point out our ADSL link or your second WAN link. You cannot route by port or protocol.
Your best bet is to use an SMTP relay where you tell your server to relay all outgoing mail through an intermediate server (rather than directly to the destination domain). Then you can setup a static route to that relay over the second WAN link to override the default route. -
Is it possible to use Remote SharedObjects with the LCDS server?
Hello,
The ActionScript documentation for Remote SharedObject
RSOs are created using the static getRemote function. This returns a reference to an object that can be shared across multiple clients by means of a server, such as Flash Media Server. If the shared object does not already exist, this method creates one.
The following code shows how you assign the returned shared object reference to a variable:
var myRemote_so:SharedObject = SharedObject.getRemote(name, remotePath, persistence);After calling this method, use SharedObject.connect() to connect the object to the application server, as shown in the following code
var myNC:NetConnection = new NetConnection();
myNC.connect(“rtmp://[yourDomain].com/applicationName”);
var myRemoteSO:SharedObject = SharedObject.getRemote(“mo”, myNC.uri, false);
myRemoteSO.connect(myNC);
To confirm that the local and remote copies of the shared object are synchronized, use the sync event.
All clients that want to share this object must pass the same values for the name and remotePath parameters.
Is it possible to create RSO's using the LCDS server instead of the Flash Media Server? If so, how?
Thanks,
OscarTom,
Thanks for your response. I decided to test this with the publish/subscribe messaging. Something I thought would work is not. Here is the simple example;
var btn:Button = new Button();
btn.label = "My Button ";
msg = new AsyncMessage();
msg.body = btn;
producer.send(msg);
Simple right? Well, this generates a fault;
1/21/2011 10:37:55.462 [ERROR] mx.messaging.Producer 'D7094E2F-2CA1-39C0-1EC6-A9DE3171E836' producer fault for 'A11AE369-8349-8970-0C10-A9DE5113DA2E'.
The LCDS log gets into more detail, AMF Deserialization ERROR....
Please notice the use of Amf0 and Amf3 methods... I thought Amf0 was a thing of the past...
Any ideas? Please help....
[LCDS]01/21/2011 10:37:55.039 [ERROR] [Endpoint.RTMP] Deserialization failed for incoming data: Unknown AMF type '15'.
flex.messaging.io.UnknownTypeException: Unknown AMF type '15'.
at flex.messaging.io.amf.Amf3Input.readObjectValue(Amf3Input.java:217)
at flex.messaging.io.amf.Amf3Input.readObject(Amf3Input.java:130)
at flex.messaging.io.amf.Amf3Input.readScriptObject(Amf3Input.java:437)
at flex.messaging.io.amf.Amf3Input.readObjectValue(Amf3Input.java:152)
at flex.messaging.io.amf.Amf3Input.readObject(Amf3Input.java:130)
at flex.messaging.io.amf.Amf3Input.readScriptObject(Amf3Input.java:437)
at flex.messaging.io.amf.Amf3Input.readObjectValue(Amf3Input.java:152)
at flex.messaging.io.amf.Amf3Input.readObject(Amf3Input.java:130)
at flex.messaging.io.amf.Amf3Input.readScriptObject(Amf3Input.java:437)
at flex.messaging.io.amf.Amf3Input.readObjectValue(Amf3Input.java:152)
at flex.messaging.io.amf.Amf3Input.readObject(Amf3Input.java:130)
at flex.messaging.messages.AbstractMessage.readExternalBody(AbstractMessage.java:654)
at flex.messaging.messages.AbstractMessage.readExternal(AbstractMessage.java:324)
at flex.messaging.messages.AsyncMessage.readExternal(AsyncMessage.java:98)
at flex.messaging.io.amf.Amf3Input.readExternalizable(Amf3Input.java:491)
at flex.messaging.io.amf.Amf3Input.readScriptObject(Amf3Input.java:420)
at flex.messaging.io.amf.Amf3Input.readObjectValue(Amf3Input.java:152)
at flex.messaging.io.amf.Amf3Input.readObject(Amf3Input.java:130)
at flex.messaging.io.amf.Amf0Input.readObjectValue(Amf0Input.java:123)
at flex.messaging.io.amf.Amf0Input.readObject(Amf0Input.java:94)
at flex.messaging.io.amf.AmfMessageDeserializer.readObject(AmfMessageDeserializer.java:227)
at flex.messaging.io.tcchunk.TCCommand.readMessage(TCCommand.java:191)
at flex.messaging.endpoints.RTMPConnection.serviceTCMessage(RTMPConnection.java:1024)
at flex.messaging.endpoints.RTMPConnection.doRead(RTMPConnection.java:610)
at flex.messaging.endpoints.RTMPProtocolHandler.doRead(RTMPProtocolHandler.java:125)
at flex.messaging.socketserver.Connection$ConnectionReader.run(Connection.java:864)
at java.util.concurrent.ThreadPoolExecutor$Worker.runTask(ThreadPoolExecutor.java:886)
at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:908)
at java.lang.Thread.run(Thread.java:662)
Thanks,
Oscar -
Using JAAS/JNDI with the Login Server
Is it possible to set up single sign-on through the Login Server
and OID for a Java portlet using JAAS and JNDI? What would be
required to set this up?I was facing same problem,
Here is I got an answer, I was doing same mistake.
You cannot authenticate with an outlook.com account when you use the management shell. You have to use a @yourtenant.onmicrosoft.com
account or an account where the domain has been associated with your O365 tenant like @contoso.com . Microsoft accounts cannot be used with the management shell.
http://community.office365.com/en-us/f/156/t/238053.aspx -
Escalation in BPM11g using "organization" and not the ldap server
Hi,
I want to implement the escalation of a task from user1 to user2.
How can i achieve this by management approval process instead of using the ldap (i.e. defining the manager and other higher approver titles and assigning the users to these titles in ldap).
What i know is we can create a logical hierarchy using Organizational Units.
I guessed that I can provide a OU hierarchy and use it for the Management Task.OK!!
Do one thing...
1) Firstly write a EJB Class and by using EJB adapter fetch all the groups and the users using EJB service call ....
Consider,
Group A Has 2, 3 Users with a manger
Group B Has 4, 5 Users with a Director
Group C Has 4, 5 Users with a CEO
and etc....
2) Send the mails to all the Users and the Manager/Director / CEO of that group respectively if a specific task is not completed by any of the users then escalate to his supervisor/Reporting-manager
Hope iam on the same page!!
Regards,
Pavan -
Capture duration time and use it in customized the SQL Server Job System Message
Hi there
I am trying to capture the job duration time and put it on the customized Job email subject.
This is the original message from SQL server, the Bold one is what I am trying to capture.
JOB RUN:
'Hello' was run on 7/30/2014 at 8:05:00 AM
DURATION:
0 hours, 0 minutes, 2 seconds
STATUS:
Succeeded
MESSAGES: The job succeeded.
The Job was invoked by Schedule 27 (Job 2). The last step to run was step 1 (Test).
Is there anyway to do that? I have tried to pull it from jobhistory and I did't have any luck.
Cheers,
MattYou can take this code and send it to a table, then create your reports
; WITH CTE as -- Use a Simple Common Table Expression
SELECT ROW_NUMBER() OVER (PARTITION BY job_name -- Add the comma separate columns that need to be unique in the table
ORDER BY ( SELECT 0 ) ) RN ,* -- If the order does not matter on the one you want to keep - the select 0 work well; otherwise add the appropriate order by to make the row you want to keep appear at the top
FROM (
select TOP 100000 job_name, run_datetime, run_duration,run_status
from
select job_name, run_datetime,run_status,
SUBSTRING(run_duration, 1, 2) + ':' + SUBSTRING(run_duration, 3, 2) + ':' +
SUBSTRING(run_duration, 5, 2) AS run_duration
from
select DISTINCT
j.name as job_name,
run_datetime = CONVERT(DATETIME, RTRIM(run_date)) +
(run_time * 9 + run_time % 10000 * 6 + run_time % 100 * 10) / 216e4,
run_duration = RIGHT('000000' + CONVERT(varchar(6), run_duration), 6)
,h.run_status
from msdb..sysjobhistory (NOLOCK)h
inner join msdb..sysjobs (NOLOCK)j
on h.job_id = j.job_id
where h.step_id = 0
) t
) t
order by job_name, run_datetime desc
)X
SELECT @@servername as [ServerName],RN,job_name,run_datetime,run_duration,run_status
FROM CTE
ORDER BY run_duration desc
Javier Villegas |
@javier_vill | http://sql-javier-villegas.blogspot.com/
Please click "Propose As Answer" if a post solves your problem or "Vote As Helpful" if a post has been useful to you -
Connecting to the RH Server - Additional Security?
We are testing using our RH8 output on RH8 Server. Setting up the environment went really smoothly except that for some reason we can't publish from our RH8 projects. We get an "Unable to Connect to the RoboHelp Server" error message. The error message even very helpfully suggests using WebHelp output instead. ROTFL! We can see the server and can even get to the default page where the output should be placed when I connect to it via a remote desktop.
Our thinking is that another level of security is required to get this to work. In previous versions there was a IIS Internet Guest Account that was required for each website. As RH8 Server doesn't use IIS we are thinking that there must be something else that links the userid I use to connect to the physical server with the userid used to logon on the Configuration Manager. If we knew this, we could apply this security and test it out.
Is this making sense? Perhaps someone out there in RH8 Server has encountered this. If it makes a difference we are using Tomcat with the JRE and the build-in database. We will change this to use SQL Server Express once our testing is complete.
Read the RoboColum(n) for mutterings on RoboHelp, Technical Communication Suite and technical communication.OK people you can all stand down as I have managed to figure out what was wrong. The "Server Name" path in my publish destination was missing one vital element. The should should be "<servername>:<port>/robohelp/server". For example if your server is called helpserver and you use port 8080 (it is recommended you do) the path would be "helpsever:8080/robohelp/server". I was missing the "server" off the end. Incidently there is an excellent discussion here with tons of useful information on the set-up and merged projects.
So now I have a successfully created and published project to test with the application. All I need to do now is merge 10 other help files and add context sensitive help. But enough already. Time to go home, have a beer and recharge for Monday. Thanks to Tulika, John, Peter, Kristan and others for the excellent resource mentioned above. Have a great weekend all.
Read the RoboColum(n) for mutterings on RoboHelp, Technical Communication Suite and technical communication. -
Using WEBUTIL to transfer files to server
We need to transfer files from Forms client to database server filesystem.
It seems, WEBUTIL_FILE_TRANSFER doesn’t provide this functionality.
We modified supplied webutil_db package body, so if the blobtable parameter is 'FILE' – closeblob procedure will use UTL_FILE to write OS file instead of updating blob in table.
Now we can call
webutil_file_transfer.client_to_db (clientfile => myclientfilename,
tablename => 'FILE',
columnname => myserverfilename,
whereclause => myserverdir
This solution is working fine, but, of course, our concern is compliance of our custom changes with future releases of WEBUTIL.
Any plans to add something like Client_To_Server procedures to webutil?Just a thought..
1) make table that accepts your blob via client_to_db.
2) write a after insert trigger that copies file to an Oracle Directory on db file system.
You could also maybe use this PLSQL ftp package.. I havent used it.. Users talk about it frequently on other forums here, namely the sql and plsql forum.
http://www.chrispoole.co.uk/apps/xutlftp.htm
Notice the "unloading blobs to database filesystem" line below.
With XUTL_FTP the transferring of the file IS the data loading process.
The file is NOT copied to disk, it's simply 'poured' straight into whatever table you like!
If this wasn't enough, it also has the other following uses:
unloading BLOBS to the database server file system (as UTL_FILE does not have a working binary implementation until 10g)
arbitrary unloading of data to remote servers
obtaining a file listing for a directory on the database server file system Message was edited by:
Mark Reichman
Message was edited by:
Mark Reichman -
I have a macbook operating OSX10.6.7. Recently backing up my ipad which had lots of photos from a recent vacation. I use this laptop as the backup server for all of my gadgets so it has thousands of photos and tons of music. It just told me that it couldn't back up the ipad bc there wasn't enough disc space. I was afraid that this would happen eventually. What next? Newer laptop with more space? I'm not sure what files I could sacrifice to free up more space as most of these are important.
What size hard drive do you have in your MacBook? The cheapest options are, a larger internal hard drive, or an external drive. Or you could get a cheap desktop PC and network to it for storage. I've got one that lives in the hall with 3 Terabytes (That's 3000gb) of storage.
-
com.sap.mw.jco.JCO$Exception: (103) RFC_ERROR_LOGON_FAILURE: This system rejects all logons using SSO tickets
in the production server.....
while testing the jco maintained for Ess applications.
if i go for uidpw method for modeldata destination i am getting the error. in the Ess pages that administrtor not in this peroid(administrator with which id i maintained jco destination)
if i assign one employee to the admin in pa30......for every employee getting the same details of admin)
I guess this problem with modeldata ......i should maintain the usermanagement method for modeldata jco destination is logon ticket.
while maintainig that ping is successfull but getting the above error.
it is the problem with production server.......of E.P
in dev and quality everything is working fine.
plz help me out.
thankyou
swapnaHi Swapna,
Please check the logon group properties for SAP system in t-code SMLG. If there is any issue with logon group then it might cause for this issue.
Refer to [Click here|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/library/user-interface-technology/wd%20java/7.0/portal%20integration/how%20to%20configure%20the%20jco%20destination%20settings.pdf] and [System Landscape Directory Process and JCo Configuration|http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/c0c1d495-048e-2b10-babd-924a136f56b5?QuickLink=index&overridelayout=true]
Hope it will helps
Regards, Arun Jaiswal -
Probloms in starting the web server
i am a peoplesoft dba. i am trying to install peoplesoft internet architecture.
the O.S is windows 2000, database is oracle, application server is using Tuxedo
6.5. the web server is weblogic 6.12. i have installed all the components and
am able to log on to the peoplesoft application in 3-tier mode.
now i am trying to set-up the 3-tier web connection. i have created a domain -
VISTDEV. the JSL port is 9000, HTTP port is 80. when i am starting the PIA service
through --- startPIA.cmd under my domain, i am getting the following error:
<Dec 26, 2003 12:24:19 PM CET> <Notice> <Management> <Loading configuration file
.\config\VISTDEV\config.xml ...>
<Dec 26, 2003 12:24:25 PM CET> <Notice> <WebLogicServer> <Starting WebLogic Admin
Server "PIA" for domain "VISTDEV">
<Dec 26, 2003 12:24:44 PM CET> <Notice> <Management> <Application Poller not started
for production server.>
<Dec 26, 2003 12:24:44 PM CET> <Notice> <WebLogicServer> <ListenThread listening
on port 8080>
<Dec 26, 2003 12:24:44 PM CET> <Emergency> <WebLogicServer> <Unable to create
a server socket for port: 443. java.net.BindException: Address in use: JVM_Bind
Perhaps another process is using port 443.>
<Dec 26, 2003 12:24:44 PM CET> <Emergency> <WebLogicServer> <The WebLogic Server
is no longer listening for connections. You should probably restart it.>
<Dec 26, 2003 12:24:44 PM CET> <Alert> <WebLogicServer> <Server shutdown has been
requested by system>
<Dec 26, 2003 12:24:44 PM CET> <Alert> <WebLogicServer> <The shutdown sequence
has been initiated.>
the DOS window closes after that. i am surprised how the port 8080 is coming into
picture.
can you please help in troubleshooting.Hi,
I suppose you have set the SSL port to 443 however, it looks like port 443 is
already in use by another process.
Regards
Mayur
"blue_jay" <[email protected]> wrote:
>
i am a peoplesoft dba. i am trying to install peoplesoft internet architecture.
the O.S is windows 2000, database is oracle, application server is using
Tuxedo
6.5. the web server is weblogic 6.12. i have installed all the components
and
am able to log on to the peoplesoft application in 3-tier mode.
now i am trying to set-up the 3-tier web connection. i have created a
domain -
VISTDEV. the JSL port is 9000, HTTP port is 80. when i am starting the
PIA service
through --- startPIA.cmd under my domain, i am getting the following
error:
<Dec 26, 2003 12:24:19 PM CET> <Notice> <Management> <Loading configuration
file
\config\VISTDEV\config.xml ...>
<Dec 26, 2003 12:24:25 PM CET> <Notice> <WebLogicServer> <Starting WebLogic
Admin
Server "PIA" for domain "VISTDEV">
<Dec 26, 2003 12:24:44 PM CET> <Notice> <Management> <Application Poller
not started
for production server.>
<Dec 26, 2003 12:24:44 PM CET> <Notice> <WebLogicServer> <ListenThread
listening
on port 8080>
<Dec 26, 2003 12:24:44 PM CET> <Emergency> <WebLogicServer> <Unable to
create
a server socket for port: 443. java.net.BindException: Address in use:
JVM_Bind
Perhaps another process is using port 443.>
<Dec 26, 2003 12:24:44 PM CET> <Emergency> <WebLogicServer> <The WebLogic
Server
is no longer listening for connections. You should probably restart it.>
<Dec 26, 2003 12:24:44 PM CET> <Alert> <WebLogicServer> <Server shutdown
has been
requested by system>
<Dec 26, 2003 12:24:44 PM CET> <Alert> <WebLogicServer> <The shutdown
sequence
has been initiated.>
the DOS window closes after that. i am surprised how the port 8080 is
coming into
picture.
can you please help in troubleshooting. -
Cannot Open HFM Application in Workspace. "The RPC server is unavailable.
Hi All,
I cannot open HFM Application from Workspace. Planning works fine.
Restarted the HFM services and tried but no use.
Error shows "The RPC Server is Unavailable. Error code:- 2147023174
Details shows following.
Trace: Error Reference Number: {2498F82B-1C14-4704-B34A-BA7145D27450}<BR>Num: 0x800706ba;Type: 0;DTime: 10/8/2012 7:57:19 PM;Svr: SERVER NAME;File: CHITRegistryWrapper.cpp;Line: 1108;Ver: 11.1.2.0.0.2762;<BR>Num: 0x800706ba;Type: 0;DTime: 10/8/2012 7:57:19 PM;Svr: SERVER NAME;File: CHFMwHITRegistry.cpp;Line: 1083;Ver: 11.1.2.0.0.2762;
Thanks.It may be worth having a read of the following doc in Oracle support as it sounds like it could be DCOM related - "Identifying and Troubleshooting DCOM Issues Affecting Hyperion Financial Management (HFM) [ID 1419144.1]"
Cheers
John
http://john-goodwin.blogspot.com/
Maybe you are looking for
-
How can I set up an autoresponse triggered by the hour rather than a day
Hi I would like to set up thunderbird so that it automatically sends an out of office response between 6.00pm and 8.00am, is there a way I can do this? Thanks
-
Error Message When Starting MBP
When I turn my MBP on, I get an error message, "conversion engine is not responding. please restart this application mac", every time. I started getting this message about a month ago before updating to Mountain Lion. My MBP was running Snow Leopard
-
HELP!!! --- Runtime in Linux?
We have a code that was supposed to execute an executable file. It uses the Runtime class. But it does not run on Linux though..help? :(
-
Hi, i am trying to write an array coming out of a for loop into a file. If i plot the array in the Front panel everything works, but if i write it to a text file some aditional characters (empty space and this rectangle) appear. The file should l
-
How to make set up with first call of method of a custom class?
Hello I have build a custom class with a few custom methods. Method1 is called per every record of internal table. I need to set up certain parameters tha are the sme for all the calls (populate the range , to fill the internal table , etc). This sh