FC Port Channel between UCS and MDS.

Hi All,
I am new to Cisco Fabric Concepts. In my enviornment i have a F port channel(8 Port Group) created on MDS 9513 switch and this Fport 
channel is connected to Cisco UCS 6296 FI. The Cisco UCS Blade servers are connected to the Fabric Interconnect .
On MDS NPIV is enabled.
Can anyone explain the below questions.
1. Why do we create an F port Channel Group and connect it to the UCS FI? Is this something similar to Brocade Edge to AG Switch Connectivity.
2. How to configure F port Channel Group in MDS . Can anyone explain with an example.
3. Do we need to make any Configuration on UCS FI ports for server connectivity and Channel port Connectivity if yes what are the steps required to 
do the same.Does the WWPN shows up in the FLOGI Database if the connectivity and configuration looks good in UCS FI and MDS.
4. What happens when a VSAN on MDS switch is added to the Port Channel.
Thanks and Regards,
Santosh surya

Look at my remarks in
https://supportforums.cisco.com/discussion/12468266/fc-port-channels-between-mds-and-ucs-fi-best-practice
1. Why do we create an F port Channel Group and connect it to the UCS FI? Is this something similar to Brocade Edge to AG Switch Connectivity.
F port channel is proprietary; therefore any such F port channel between UCS FI and Brocade doesn't work.
2. How to configure F port Channel Group in MDS . Can anyone explain with an example.
see eg.
https://supportforums.cisco.com/sites/default/files/legacy/9/9/2/53299-UCS_1-4-1_F-port_channel-trunk-v1.pdf
3. Do we need to make any Configuration on UCS FI ports for server connectivity and Channel port Connectivity if yes what are the steps required to 
see eg.
https://supportforums.cisco.com/sites/default/files/legacy/9/9/2/53299-UCS_1-4-1_F-port_channel-trunk-v1.pdf
Does the WWPN shows up in the FLOGI Database if the connectivity and configuration looks good in UCS FI and MDS.
flogi database is on the MDS, not FI; there are however UCS CLI commands, like "show npv ...."
4. What happens when a VSAN on MDS switch is added to the Port Channel.
If its not created on UCS, it will just not become the status "up"

Similar Messages

  • Create port channel between UCS-FI and MDS 9124 (F Mode)

    Dear Team,
    We were trying to create  port channel between UCS FI and MDS 9124
    But the port channel not getting active in F mode on MDS 9124
    FI is in FC End Host Mode
    We have enabled FC uplink trunking on FI
    We have enabled NPIV on MDS
    We have enabled trunk on MDS
    FI and MDS in default VSAN
    To check we changed the FI mode to FC Switching mode and port channels became active but in E mode
    when we enabled FC uplink trunking on FI and FC Switching mode port channels became active in TE mode
    but in both the above cases showflogi database shows WWPN of SAN alone not showing any from FI.
    How to achive this?
    Have read that no need to change the swicthing mode to FC Switching mode and keep as FC Endhost mode
    SO how to achieve Port channel with F mode in MDS and FI ( Mode showing as NProxy)
    Does it has to do anything with MDS NX-OS version? (https://supportforums.cisco.com/thread/2179129)
    If yes how to upgrade as license for ports came along with Device and we do not have any PAC/PAK or license file as it came
    with license
    Also we have seen 2 files availabe for download (m9100-s2ek9-kickstart-mz.5.2.8b.bin and m9100-s2ek9-mz.5.2.8b.bin) which to use
    Thanks and Regards
    Jose

    Hi Jo Bo,
    what version of software if your MDS running?
    On your UCS do connect nxos and show inteface brieft and look at the mac address.
    it is possible that you might be hitting the bug below. if this is the case you might need to upgrade the firmware on your MDS.
    Add MAC OUI "002a6a", "8c604f", "00defb" for 5k/UCS-FI
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCty04686
    Symptom:
    Nexus switch unable to connect any other Nexus or other Cisco Switch in NPV mode with a F port-channel.   Issue might be seen in earlier 5.1 releases like
    5.1.3.N1.1a
    but not the latest
    5.1.3.N2.1c
    release. Issue is also seen in
    5.2(1)N1(1)
    and
    6.0(2)N1(1)
    and later releases.
    Conditions:
    Nexus configured for SAN PortChannels or NPIV trunking mode Nexus connected to UCS via regular F port channel where UCS in NPV mode  NPV edge switch: Port WWN OUI from UCS FI  or other Cisco manufactured switch:  xx:xx:00:2a:6a:xx:xx:xx   OR  xx:xx:8c:60:4f:xx:xx:xx
    Workaround:
    Turn-off trunking mode on Nexus 5k TF-port Issue does not happen with standard  F-PORT Remove SAN Portchannel config
    Further Problem Description:
    To verify the issue please collect  show flogi internal event-history errors  Each time the port is attempted OLS, NOS, LRR counters will increment. This can be determined via the following output,  show port internal info all show port internal event-history errors

  • SAN Port Channel between 6120 and Brocade

    Has anyone setup or know how to setup a SAN Port Channel between 6120s and a Brocade FC switch? I know that it requires UCS firmware 1.4 but I don't know what the Brocade requirements are.

    The SAN port channel is Cisco proprietory. You cannot setup SAN port channel with Brocade. Sorry

  • Port channel between Nexus and Server is initializing

    Hi all, 
    I will need your help. 
    I have Nexus 5000, there is a POrt Channel between Nexus and Server, but one port always is in initializing.
    sh interface Ethernet101/1/27
    Ethernet101/1/27 is down (initializing)
      Hardware: 1000/10000 Ethernet, address: c8f9.f920.5b5c (bia c8f9.f920.5b5c)
      MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec
      reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA
      Port mode is trunk
      auto-duplex, 10 Gb/s, media type is 10G
      Beacon is turned off
      Input flow-control is off, output flow-control is on
      Rate mode is dedicated
      Switchport monitor is off
    Any idea?
    Regards

    how many ports are you using in this port channel.
    can you paste the configuration of the channel ports and the interface.
    check the sh log if you are getting any log related to the port channeling.

  • LACP port channel between 6509 and Nexus 7K

    We are in the process of migrating from dual 6509's to dual 7010's.  We have moved our 5k/2K's behind the 7K and have layer 2 up between the 6509 and 7K.  This link is configured as a port channel with 2 1gig links using LACP.  The port channel is up and working and traffic is passing but it doesn't appear the load it equally distributed between the links.  Both the 7K and 6K are setup for src-dst-ip for the load balancing.  The links have been in place for over 12 hours and I would have expected them to "equal" out.  Has anyone had this issue in or is this to be expected?  For clarification there is not VPC inolved in this configuration it is simply a port-channel between one 6509 and a 7010.
    Thanks,
    Joe

    We are in the process of migrating from dual 6509's to dual 7010's.  We have moved our 5k/2K's behind the 7K and have layer 2 up between the 6509 and 7K.  This link is configured as a port channel with 2 1gig links using LACP.  The port channel is up and working and traffic is passing but it doesn't appear the load it equally distributed between the links.  Both the 7K and 6K are setup for src-dst-ip for the load balancing.  The links have been in place for over 12 hours and I would have expected them to "equal" out.  Has anyone had this issue in or is this to be expected?  For clarification there is not VPC inolved in this configuration it is simply a port-channel between one 6509 and a 7010.
    Thanks,
    Joe

  • Port-channel between ACE4710 and switch

                   Hi all,
    I have configured port-channels on ACE and switch. Full-duplex and speed 1000Mbps are set on both sides. The configurations of port-channel on both sides is same. But there are output drops on the switch. See:
      Last clearing of "show interface" counters 00:31:24
      Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 536
    Why there are output drops on the switch? There is no half-duplex and both sides have the same speeds.
    Thank you
    Roman

    Hi Roman,
    Please paste the configuration of the ACE and Switch
    Cesar R
    ANS Team

  • FC port channels between MDS and UCS FI best practice?

    Hi,
    We would like to create FC port channels between our UCS FI's and MDS9250 switches.
    At the moment we have 2 separate 8Gbps links to the FI's.
    Are there any disadvantages or reasons to NOT do this?
    Is it a best practice?
    Thanks.

    As Walter said, having port-channels is best practice.  Here is a little more information on why.
    Let's take your example of two 8Gbps links, not in a port-channel ( and no static pinning ) for Fibre Channel connectivity:
    Hosts on the UCS get automatically assigned ( pinned ) to the individual uplinks in a round-robin fashion.
    (1)If you have some hosts that are transferring a lot of data, to and from storage, these hosts can end up pinned to the same uplink and could hurt their performance. 
    In a port-channel, the hosts are pinned to the port-channel and not individual links.
    (2)Since hosts are assigned to an individual link, if that link goes down, the hosts now have to log back into the fabric over the existing working link.   Now you would have all hosts sharing a single link. The hosts will not get re-pinned to a link until they leave and rejoin the fabric.  To get them load balanced again would require taking them out of the fabric and adding them back, again via log out, power off, reload, etc...
    If the links are in a port-channel, the loss of one link will reduce the bandwidth of course, but when the link is restored, no hosts have to be logged out to regain the bandwidth.
    Best regards,
    Jim

  • What can be the max difference in cable lengths that we can have between the ISLs in a port-channel between MDS switches?

    Hello All
    What can be the max difference in cable lengths that we can have between the ISLs in a port-channel between MDS switches? Do we have any documentation?
    Thanks
    Chetan

     competitive solution instead recommends a distance variance of 30 meters or less among ISLs within a trunk. If the distance variance is greater than 30 meters, undesired and degraded performance will occur. For example, if a trunk has a distance of 100 kilometers, the competitive trunking solution allows a cable length variance of only 0.03 percent!
    ref;
    http://www.cisco.com/c/en/us/products/collateral/storage-networking/mds-9500-series-multilayer-directors/white_paper_c11-534878.html
    hth
    regards
    inayath
    **********PLZ dont forget to rate if this info is helpfull.

  • Configure port channel between IO Module and FI

                       Hi,
    I have the current setup
    UCS chassis (4 uplinks) --> FI --> (Port channel) --> N5K --> (port channel) --> VSS 6500
    I configure port channel between IO Module and the FI by changing to policy to "Port Channel" and set the link to 4
    FI has created a portchannel under "Internal" containing all the FI interfaces that are connected to the IO module.
    I have installed ESXI on a blade but i was unable to reach it, even the esx was unable to ping the gateway.
    VLAN tagging is enabled from the ESX server.
    I have issued the command "show mac address-table | inc <mac address of the vnic assigned from thre service profile> on both the N5K and thr 6500 and the mac is there.
    I have allowed all the vlans on the vNIC from the service profile.
    am I missing anything?
    thanks

    Hello,
    Can you please check whether your ESXi vmkernel interface ip address learned on right VLAN on FI / upstream switch or not.
    connect nxos
    show mac-address-table | inc 
    Padma

  • Interface port-channel btw N2K and Brocade VDX

    Dear all,
    I tried to configure a port-channel between a nexus 2K (2FEX) and a brocade VDX (VDX6710).
    As you seen below, my configuration :
    N2K
    Po10
    switchport access vlan 200
    Eth101/1/6
    switchport access vlan 200
    channel-group 10 mode active (used LACP)
    Eth102/1/6
    switchport access vlan 200
    channel-group 10 mode active (used LACP)
    VDX
    interface Port-channel 27
    vlag ignore-split
    speed 1000
    switchport
    switchport mode access
    switchport access vlan 200
    spanning-tree shutdown
    no shutdown
    interface GigabitEthernet 21/0/31
    channel-group 27 mode active type standard
    lacp timeout long
    no shutdown
    interface GigabitEthernet 22/0/31
    channel-group 27 mode active type standard
    lacp timeout long
    no shutdown
    Unfortunately, we can't up the link for interfaces and so the port-channel.
    We have the next message from the N5K for FEX :
    %ETHPORT-5-IF_ADMIN_UP: Interface Ethernet101/1/6 is admin up .
    %ETHPORT-5-SPEED: Interface Ethernet101/1/6, operational speed changed to 1 Gbps
    %ETHPORT-5-IF_DUPLEX: Interface Ethernet101/1/6, operational duplex mode changed to Full
    %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet101/1/6, operational Receive Flow Control state changed to off
    %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet101/1/6, operational Transmit Flow Control state changed to on
    %ETHPORT-5-IF_UP: Interface Ethernet101/1/6 is up in mode access
    %ETHPORT-5-IF_DOWN_NONE: Interface Ethernet101/1/6 is down (None)
    %ETHPORT-5-IF_DOWN_ERROR_DISABLED: Interface Ethernet101/1/6 is down (Error disabled. Reason:BPDUGuard)
    Any idea about the configuration ?
    Thanks for your help.
    Matthieu

    Fexes are really made to connect hosts and not switches .  So the ports should not see bpdu's so bpduguard is err-disabling the ports.          
    Spanning Tree Protocol
    HIFs go down with the BPDUGuard errDisable message
    HIFs go down accompanied with the message, BPDUGuard errDisable.
    Possible Cause
    By default, the HIFs are in STP edge mode with the BPDU guard enabled.  This means that the HIFs are supposed to be connected to hosts or  non-switching devices. If they are connected to a non-host device/switch  that is sending BPDUs, the HIFs become error-disabled upon receiving a  BPDU.
    Solution
    Enable the BPDU filter on the HIF and on the peer connecting device.  With the filter enabled, the HIFs do not send or receive any BPDUs. Use  the following commands to confirm the details of the STP port state for  the port:

  • SAN Port-Channel between Nexus 5000 and Brocade 5100

    I have a Nexus 5000 running in NPV mode connected to a Brocade 5100 FC switch using two FC ports on a native FC module in the Nexus 5000. I would like to configure these two physical links as one logical link using a SAN Port-Channel/ISL-Trunk. An ISL trunking license is already installed on the Brocade 5100. The Nexus 5000 is running NX-OS 4.2(1), the Brocade 5100 Fabric OS 6.20. Does anybody know if this is a supported configuration? If so, how can this be configured on the Nexus 5000 and the Brocade 5100? Thank you in advance for any comments.
    Best regards,
    Florian

    I tried that and I could see the status light on the ports come on but it still showed not connected.
    I configured another switch (a 3560) with the same config and the same layout with the fiber and I got the connection up on it. I just cant seem to get it on the 4506, would it be something with the supervisor? Could it be wanting to use the 10gb port instead of the 1gb ports?

  • Port Channels - WLC 5508 and 4510

    LACP and PAgP are not supported on the controller and it appears that the 4500 series will not use LAG.
    interface Port-channel10
     description WLC Port-Channel
     switchport
     switchport mode trunk
     service-policy input AutoQos-4.0-Input-Policy
     service-policy output OUTPUT-PRIORITY-POLICING-ETHERCHANNEL
    interface GigabitEthernet3/1
     description Cisco 5508 Wireless Controller 
     switchport mode trunk
     channel-group 10 mode active
     spanning-tree link-type point-to-point
    interface GigabitEthernet3/2
     description Cisco 5508 Wireless Controller 
     switchport mode trunk
     channel-group 10 mode active
     spanning-tree link-type point-to-point
    I am getting the error, "lacp not enabled on remote port..". I removed the 2nd fiber cable and removed the channel-group so I could get the WLC back online. Any help would be greatly appreciated. 

    In order to get the ether channel to work with the WLC you need to change your configuration from:
    interface GigabitEthernet3/1
     channel-group 10 mode active
    interface GigabitEthernet3/2
     channel-group 10 mode active
    To mode ON
    interface GigabitEthernet3/1
     channel-group 10 mode on
    interface GigabitEthernet3/2
     channel-group 10 mode on
    Mode ON tells the switch to do Link Aggregation Protocol and does try and negotiate using one of the two control protocols LACP or PAgP.
    using mode ON is part of the configuration guide when enabling Cisco WLC LAG option.

  • Port channel WLC 5508 and 3750

    Hi All,
    I want to configure Port channel for WLC 5508 and cisco 3750 Stack Switch. What changes I need to make on WLC and where?
    Thanks
    Jagdev

    Thanks Chris,
    LAG is enable on WLC, and Port channel is configured on 3750, Please see the configration and Port channel status below:-
    (Cisco Controller) >show lag summary
    LAG Enabled
    interface Port-channel14
    description Port Channel to WLC001
    switchport trunk encapsulation dot1q
    switchport mode trunk
    end
    sh etherchannel 14 summary
    Flags:  D - down        P - bundled in port-channel
            I - stand-alone s - suspended
            H - Hot-standby (LACP only)
            R - Layer3      S - Layer2
            U - in use      f - failed to allocate aggregator
            M - not in use, minimum links not met
            u - unsuitable for bundling
            w - waiting to be aggregated
            d - default port
    Number of channel-groups in use: 14
    Number of aggregators:           14
    Group  Port-channel  Protocol    Ports
    ------+-------------+-----------+-----------------------------------------------
    14     Po14(SD)        LACP      Gi1/0/22(I) Gi2/0/22(I)
    sh run int g1/0/22
    Building configuration...
    Current configuration : 209 bytes
    interface GigabitEthernet1/0/22
    description Trunk to WLC001 DistPort1
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 254
    switchport mode trunk
    channel-group 14 mode active
    end
    sh run int g2/0/22
    Building configuration...
    Current configuration : 209 bytes
    interface GigabitEthernet2/0/22
    description Trunk to WLC001 DistPort2
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 254
    switchport mode trunk
    channel-group 14 mode active
    end

  • Huge Sized download taking place at port 8530 between clients and WSUS\SUP of secondary site

    Hi Guy's
    Need a solution to the issue, the SCCM 2012 clients under a secondary site { Secondary site with SUP\WSUS } are downloading 200Mb + data at port 8530. This seems quite abnormal.
    Need to know answer of below
    1- Actual size of catalog what clients should download or path where on WSUS is stored
    2- How to restrict a huge sized download between WSUS and CM 2012 client
    This is not the case where clients are directly reporting to Primary size.
    Regards
    Sushain Kapoor
    Regards Sushain KApoor

    Hi Jason
    Just a little clarity, will the client download information for a particular product or all the products selected in wsus.
    Eg: Windows 7 systems will download the catalog information of Windows 7 only against selections made in WSUS. Or it will download the windows XP and windows vista and other product information also. This particular question i am asking as i see only 300
    updates as found in windowsupdate.log and not the thousands synced in WSUS
    Is the update metadata exported using the wsusutil.exe the actual catalog size what clients are downloading
    Regards Sushain KApoor

  • 8Gig Port Channel between two 6509s

    Hey all,
    I have two 6509s that I'm trying to configure an 8 Gig trunk/port channel. I have an 8 port fiber module in slot 3 on both switches. When I use the following command: "set port channel 3/1-8" on it seems to take the command, but if I do "show port channel" it shows two groups:
    3/1-4
    3/5-8
    Is there a limit as to how many gigs a port channel can be? If not, why does it split it like this?
    I should also note I'm using dot1q for the trunks using Auto mode on one switch and Desirable on the other.
    Thanks,
    Scott

    I did a show port cap on the interfaces and I didn't see any sort of restriction. I decided to run the command again 'set port channel 3/1-8 on' and for some reason it seemed to work this time. Not sure what changed, but it's working now.
    Thanks for your help!

Maybe you are looking for

  • Memory leak with Swing application

    My application uses more and more memory as I use it. However, if it is working like I think, it is not creating more objects and has no reason to use more memory. When the application is minimized a lot of that memory is freed up. Does anyone know w

  • Billing doc not released to accounting

    Hi ! What can be the reasons that a billing document is not automatically released to accounting? I know one reason - that is when there is a posting block assigned to the billing document type . Plz correct me if I am wrong with the above reason,and

  • How i can i prevent Apps from being dragged out from dock?

    Before Mavericks i once applied some switch via command line that prevented removing Applications via dragging out. But this way it still allowed changing the order or still allowed remvoing via right-click menu. Sadly i cannot find the command anymo

  • Mail Crashes with EXC_BAD_ACCESS

    Hello, over the last few weeks, mail has begun crashing. It started out happening once a day or so and now it's crashing nearly every hour. Below is the crash log: Date/Time: 2006-08-17 06:09:23.467 -0700 OS Version: 10.4.7 (Build 8J2135a) Report Ver

  • Constant password rejection in Lion, using iCloud