FC Port Channel & Trunking

Hi, Cisco Experts:
Can I have a definitive answer to the following?
q1.
EMC mentioned that they do not support FC Port Channel & Trunking with regard to our UCS Fabric Interconnects/MDS/VNX5300?
Is that any truth in that?
We are trying a Cisco UCS solutions with MDS and EMC VNX in the mix-SAN Boot basically, ESXi 5.1 and all others.
q2.
From MDS all the ways up to EMC VNX, is there such concept too-FC Port Channel & Trunking, assuming we are doing FC Port Channel & Trunking from FInterconnect to MDS?
Please let me know.
Appreciate it.
SiM

Hi Sim,
We support FC port channel and trunking between UCS FI and MDS.
Is EMC saying about the port channel between the MDS and VNX? Is there any document EMC pointed out?
With respect to booting from SAN, yes, you can boot from SAN with MDS and EMC VNX as long as the OS is supported in the UCS system. You can refer to
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html for the supported OS versions.
Hope this answers your question.
-Ganesh

Similar Messages

  • MDS Code Level for UCS FC Port Channel/Trunking

    What is the required MDS code level needed to support FC Port-Channeling/Trunking on a 9222i, 9148, or 9509/9513 w/ Gen2 line cards to UCS 1.4(3)?
    I know the fport-channel-trunk feature is needed and was released in MDS 4.2 code but I have seen documents that this level of code wont support these features when used to connect to Cisco UCS. 
    Can someone confirm?  Is NXOS 5.0(4) or higher required?

    Doug,
    I wrote the doc almost a year ago and it doesn't have the latest interop matrix support information. The current MDS NX-OS support is located in this doc: http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/interoperability/matrix/intmatrx.html
    While, I wish this was also duplicated in UCS docs, they are more or less taking the stance that 3rd party (Cisco MDS is this case) interop is maintained by the 3rd party. EMC, Netapp, or even Cisco.
    It would be a nightmare updating UCS docs with 3rd party qualifications and support.
    The short answer to your question is:
    UCS 1.4(1), 1.4(2), 1.4(3) Is supported by MDS9000: 3.3(4a), 3.3(5), 4.2(1a), 4.2(1b), 4.2(3a), 4.2(5), 5.0(1a), 5.0(4), 5.0(4c)
    NPV was introduced in MDS 3.3. f port-channel/trunk was introduced in MDS 4.2.
    As Ram mentioned above, 4.2(5) is what I would recommend if I wanted to implement f port-channel and/or f port-trunk. I have also had recent experience with 4.2(5) and it worked great with a large UCS f port-channel/trunk implementation
    The specific switch limitations I mentioned in my doc still exist. Only certain models of MDS will support f port-trunk. Almost all models will support f port-channel.
    Dave

  • Fabric Interconnect To MDS 9148 FC Port Channel/Trunks

    Is it possible to create both a Port Channel and Trunk on a Cisco MDS 9148? Yes correct?
    Or can I only trunk between the 2 MDS switches and not the MDS to Fabric Interconnect?
    These FC links would be connected to a 2248XP Fabric Interconnect carrying multiple VSANs from the MDS to the Fabric Interconnect.
    Thanks

    Hello,
    Yes, you can have trunk links grouped into port channel ( F port-channel trunking ) between FI and MDS.
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_0101.html
    Padma

  • F-port-channel-trunk disruptive or not?

    Hi,
    We have a N5K with NPIV configured and and MDS9148 we're gonna setup a port channel and have come to the conclusion that we need the F-port-channel-trunk feature enabled on the MDS side.
    Question: Is enabling the F-port-channel-trunk feature on the MDS disruptive or non-disruptive?
    --M

    It's too late; I would say it is disruptive; however, the disruption is so short, that you didn't notice it. Similar without non F-port trunking channeling: using a link: the lost sessions are simply redistributed over the remaining links; new flogi is necessary.

  • Port-channel / Trunking / VSAN

    Hi all,
    I have a quick question...
    I enabled trunking for all vsans and created a port-channel. I want to use this port-channel for all my vsans.
    Does it matter in which vsan I add my port-channel?
    If it doesn't matter why can I assign a port-channel to a vsan?
    Cheers,
    Mike

    Mike,
    It should be the same configuration on both sides for the port-channel to come up. The reason why you can assign a port-channel to a VSAN is that if you are using an E port then it depends on the matching port-channel VSAN to come up.
    TE Port functionality is specific to MDS for enhanced ISL capabilities. E ports can be used for non-cisco switches to make the trunk work seamlessly as an E port.
    You can refer to the following for more info:
    http://www/en/US/docs/storage/san_switches/mds9000/sw/rel_3_x/configuration/guides/cli_3_4_x/trnk.html
    http://www/en/US/docs/storage/san_switches/mds9000/sw/rel_3_x/configuration/guides/cli_3_4_x/pc.html
    Hope this helps.
    - Nikhil

  • Xconnect 20Gb Port-channel over MPLS Possible?

    Can anybody confirm if you can establish an Xconnect between two 20Gb port-channels (2x 10Gig bundle).  The core is 40Gig and running MPLS.  We have many gigabit pseudowires running over it already.
    Our intention is to terminate 10Gig server traffic on 4900M's and then have a 20Gb Port channel trunk link into a 6500 (which is part of the MPLS cloud).   We would then issue the xconnect directly on the 20Gig port channel in order to traverse the MPLS Core.
    Has anyone configured this before?  Are there any caveats to watch out for?  What sort of performance hit (if any does) xconnect functionality have on 10Gig Traffic.

    Hi,
    Yes it's supported but test it first (as always ;-) )
    HTH
    Laurent.

  • How to configure a port channel with VLAN trunking (and make it work..)

    We're trying to configure a port channel group with trunked ports to connect a NetApp HA pair. We want to create two data LIFs and connect them to the switch stack.  We are trying to create 2 data lifs, one for cifs and one for nfs that are on different vlans.
    We want the same ports to be able to allow multiple vlans to communicate. (trunked)
    These data lifs should be able to fail over to different nodes in the HA pair and still be able to communicate on the network.
    What this means is that we have to connect 4 ports each for each node in the NetApp HA Pair to the switches and create a port channel of some type that allows for trunked vlans. When we configure the ports, the configuration is as follows (below):
    We are only able to configure an IP on one of the vlans.
    When we configure an IP from another vlan for the data lif, it does not respond to a ping.
    Does anyone have any idea what I'm doing wrong on the Cisco switch?
    interface GigabitEthernet4/0/12
    description Netapp2-e0a
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet4/0/13
    description Netapp2-e0c
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet6/0/12
    description Netapp2-e0b
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet6/0/13
    description Netapp2-e0d
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface Port-channel20
    description Netapp2-NFS
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    spanning-tree portfast
    spanning-tree bpduguard enable
    end

    Our problem was fixed by the storage people.  They changed the server end to trunk, and the encapsulation / etherchannel.
    I like all the suggestions, and they probably helped out with the configuration getting this to work.
    Thanks!
    interface Port-channel20
    description Netapp2-NFS
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    interface GigabitEthernet4/0/12
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet4/0/13
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet6/0/12
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet6/0/13
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active

  • Difference between Trunk links and port channel

    Hi 
    Can anyone please explain me the difference between the Trunk links and Ether channel ?

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    As the other posters have already described, in Cisco parlance, a "trunk" is a link that carries VLAN tagged frames.  (Note, Cisco has two technologies for these, ISL [old/proprietary] and IEEE 802.1Q [vendor independent].)  An Etherchannel (also called a port-channel) is one logical link that includes one or more physical links.  (Note, although Etherchannel can run across just one link, normally more than one link is configured.  Older and most Cisco implementations support up to 8 links in one channel bundle.  There's also multiple Cisco technologies that support Etherchannels, such as manual/PAgP[Cisco/old]/LACP[IEEE 802.3ad].)
    Trunk links might also be configured on an Etherchannel link.

  • SGE2010 port-channel and trunking config question

    I have port-channels configured and working for the native VLAN on multiple SGE2010s. I now want to add multiple VLANs and enable trunking for the port-channel. I am not clear on the appropriate way to enable trunking as it can be enabled on the port and on the port-channel. The ports and port-channel are currently in access mode. If anyone can provide the correct configuration, I would appreciate the guidance. I also need to get the port-channels and trunking working with 3Com 4500 & 4200s. If you know of any configuration issues, again any guidance would be appreciated

    Hi Jacqueline,
    Sorry Juans answer needs some correction, but I am grateful for Juans participation.
    The SGE2010 does not support a CLI.
    There is a unsupported CLI,  that someone plastered somehwere on this community, but i must admit i still like to use the GUI.
    The software on the SGE2XXX was recently updated so you can find that on the cisco.com website.
    I have created a link below  to a recording i just made,  regarding Link aggregation on the SGE2XXXX, i thnk if you see the 11 minute recording a couple of times, maybe pause it, play with your switch, it  will start to make sense.
    you can't breat the switch by configuring it
    click here to see a recording of me creating a Link aggregation between two switches
    regards Dave

  • Do I configure spanning-tree port type ed trunk on LACP port-channels

    Hello,
    Can't seem to see a clear answer and wondering if something could offer some advice please?
    We are using LACP aggregation across all our 10 gig attached servers and also trunking them.  We're running a VPC pair of 5596 Nexus.
    For a standard trunk port I always add the spanning-tree port type edge trunk to the interface config.
    However I think I should be adding this to the overiding port-channel config.  At present a colleague has configured the VPC below omitting the spanning-tree port type config.
    interface port-channel100
      description a-server
      switchport mode trunk
      switchport trunk allowed vlan 100
      vpc 100
    The port member configs are these which do contain the spanning tree port type:
    interface Ethernet1/1
      description a-server(1)
      switchport mode trunk
      switchport trunk allowed vlan 100
      spanning-tree port type edge trunk
      channel-group 100 mode active
    I always try to keep the overiding port channel config the same as its members and obviously for most config, you can't have disparate configs anyway.
    However for the spanning tree config the NexOS allows you to have the members with spanning tree port types and not have to reflect that in the port-channel.
    However I have this issue with STP:
    Switch1# show spanning-tree interface po100
    Vlan             Role Sts Cost      Prio.Nbr Type
    VLAN0100         Desg BKN*200       128.4996 (vPC) Network P2p *BA_Inc
    Is this due to the inconsistency with my port channel to member configs?
    Any advice would be gratefully accepted.
    Thanks!

    Hi Paul, there are some parameters you can define on individual ports and there are some of them that will be inherited from the port-channel configuration no matter what has been configured under the infidividual ports. Spanning-tree configuration is one of the inherited ones. As soon as the port joins into a port-channel, it will start to use spanning-tree settings under the port-channel. When it leaves the channel, then it can continue to use the individual configuration.
    There is a nice summary here under NX-OS Interface Conf Guide > Port-Channel Conf:
    http://www.cisco.com/en/US/docs/switches/datacenter/sw/6_x/nx-os/interfaces/configuration/guide/if_portchannel.html#wp1798338
    Evren

  • Port Channel and VLAN trunking

    When configuring trunking of VLANS accross a Port Channel, do we need to configure vlan pruning on both the port-Channel port and the physical ports ???
    E.g. do I need to apply the "switchport trunk allowed vlan add " command under each physical port and the port channel port ? Or only under the port channel port ?
    Thanks

    In short, yes. Configure the port channel interface exactly as you do the physical interfaces and both ends should be an exact match. otherwise you will have problems getting the channel to come up or stay up.
    -Mark

  • Right way of configuring higher MTU over a Port Channel

    Hi guys,
    I have a running critical Port-Channel between two locations.
    Here's the config
    SW1:
    interface Port-channel2
     switchport
     switchport trunk encapsulation dot1q
     switchport mode trunk
    end
    interface GigabitEthernet1/45
     switchport trunk encapsulation dot1q
     switchport mode trunk
     channel-protocol lacp
     channel-group 2 mode active
    end
    interface GigabitEthernet1/46
     switchport trunk encapsulation dot1q
     switchport mode trunk
     channel-protocol lacp
     channel-group 2 mode active
    end
    SW2
    interface GigabitEthernet1/1
     switchport trunk encapsulation dot1q
     switchport mode trunk
     channel-protocol lacp
     channel-group 2 mode passive
    end
    interface GigabitEthernet1/2
     switchport trunk encapsulation dot1q
     switchport mode trunk
     channel-protocol lacp
     channel-group 2 mode passive
    end
    interface Port-channel2
     switchport
     switchport trunk encapsulation dot1q
     switchport mode trunk
    end
    Now I need to increase the MTU from default value to 9198. What the right way to do it and avoid any connectivity loss, PortChannel restart.
    Does it matter what switch I start first?
    Thanks!
    L.E. both SW are WS-C4948

    Hi,
    Because you are using layer 2 interfaces - there is no fragmentation support at layer 2, and interfaces receiving frames which have an unsupported size will be dropped.
    I think the best way for you to proceed is to lab this up; and verify what happens - it may be that you need to make changes on switches at either end of the channel within a very short time frame to prevent too large an outage.
     When you are ready to maike your change - think the best way to do this is to use the interface range command, and apply the 'mtu' command to all the interfaces in this range. I don't think it matters which switch you apply this change to first, and I don't believe if you are hinting at the 802.3ad (controlled by system-priority) decision maker, that it makes any difference.
    HTH
    Mike

  • ASA 5585 port-channels

    I want to create a port-channel with 2 10Gbs interfaces on 2 ASA 5585 firewalls, and set them up in a failover pair.
    In order to do this, do I simply put two 10Gbs interfaces into a channel and then configure the IP addressing and failover address on the logical port-channel interface? (aka interface po1).
    Any limitations with this?

    Yes, that is exactly what you do..
    Create portchannel on switch and ASA
    Trunk the vlan on switch side
    Create logical interfaces on ASA

  • Port-channel question on 9148

    hey I have a question about  port-channel.
    we have a port-channel 10 which contains 4 interfaces as below.
    my question is how the port-channel associated with the servers?  I mean the output "sh flogi database" as below........
    do we need to add port-channel as a zone member ? I think the answer is no since I don;t see the port-channel as a zone member....
    =================================================================
    tormds01# sh interface port-channel  10
    port-channel 10 is up
        Hardware is Fibre Channel
        Port WWN is 24:0a:54:7f:ee:a0:d5:48
        Admin port mode is auto, trunk mode is on
        snmp link state traps are enabled
        Port mode is F
        Port vsan is 510
        Speed is 32 Gbps
        5 minutes input rate 124316072 bits/sec, 15539509 bytes/sec, 9919 frames/sec
        5 minutes output rate 2205921104 bits/sec, 275740138 bytes/sec, 141424 frames/sec
          43540499847 frames input, 70772376296224 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          237450525827 frames output, 442040501099476 bytes
            0 discards, 0 errors
          0 input OLS, 0 LRR, 0 NOS, 0 loop inits
          0 output OLS, 0 LRR, 0 NOS, 0 loop inits
        Member[1] : fc1/1
        Member[2] : fc1/5
        Member[3] : fc1/9
        Member[4] : fc1/13
        Interface last changed at Tue Apr  8 22:16:49 2014
    tormds01# sh flogi database
    INTERFACE        VSAN    FCID           PORT NAME               NODE NAME      
    fc1/3            510   0x860000  50:06:01:64:3d:e0:24:d0 50:06:01:60:bd:e0:24:d0
                               [torvnx01_spa0]
    fc1/7            510   0x860100  50:06:01:6c:3d:e0:24:d0 50:06:01:60:bd:e0:24:d0
                               [torvnx01_spb0]
    fc1/11           510   0x860200  50:06:01:60:3d:e0:24:d0 50:06:01:60:bd:e0:24:d0
                               [torvnx01_spa2]
    fc1/15           510   0x860300  50:06:01:68:3d:e0:24:d0 50:06:01:60:bd:e0:24:d0
                               [torvnx01_spb2]
    port-channel 10  510   0x860400  24:0a:54:7f:ee:92:3e:80 21:fe:54:7f:ee:92:3e:81
    port-channel 10  510   0x860401  20:01:04:25:b5:3a:00:8f 20:01:00:25:b5:30:00:8f
                               [mcvhes0101hba0]
    port-channel 10  510   0x860402  20:01:04:25:b5:3a:00:9f 20:01:00:25:b5:30:00:9f
                               [mcvhes0102hba0]
    port-channel 10  510   0x860404  20:01:04:25:b5:3a:00:6f 20:01:00:25:b5:30:00:6f
                               [mcvhes0103hba0]
    port-channel 10  510   0x860408  20:01:04:25:b5:3a:00:7f 20:01:00:25:b5:30:00:7f
                               [mcvhes0104hba0]
    port-channel 10  510   0x86040f  20:01:04:25:b5:3a:00:4f 20:01:00:25:b5:30:00:4f
                               [mcvhes0105hba0]
    port-channel 10  510   0x860410  20:01:04:25:b5:3a:00:5f 20:01:00:25:b5:30:00:5f
                               [mcvhes0106hba0]
    port-channel 10  510   0x860417  20:01:04:25:b5:3a:00:2f 20:01:00:25:b5:30:00:2f
                               [mcvhes0107hba0]
    port-channel 10  510   0x860418  20:01:04:25:b5:3a:00:0f 20:01:00:25:b5:30:00:0f
                               [mcvhes0109hba0]
    port-channel 10  510   0x86041b  20:01:04:25:b5:3a:00:bf 20:01:00:25:b5:30:01:bf
                               [mcvhes0110hba0]
    port-channel 10  510   0x86041d  20:01:04:25:b5:3a:00:1f 20:01:00:25:b5:30:00:1f
                               [mcvhes0111hba0]
    port-channel 10  510   0x86041e  20:01:04:25:b5:3a:00:3f 20:01:00:25:b5:30:00:3f
                               [mcvhes0108hba0]
    port-channel 10  510   0x86041f  20:01:04:25:b5:3a:00:ff 20:01:00:25:b5:30:01:ff
                               [mcvhes0112hba0]
    port-channel 10  510   0x860423  20:01:04:25:b5:3a:00:df 20:01:00:25:b5:30:01:df
                               [mcvhes0113hba0]
    port-channel 10  510   0x860425  20:01:04:25:b5:3a:00:ef 20:01:00:25:b5:30:01:ef
                               [mcvhes0114hba0]
    port-channel 10  510   0x860426  20:01:04:25:b5:3a:00:cf 20:01:00:25:b5:30:01:cf
                               [mcvhes0115hba0]
    port-channel 10  510   0x860427  20:01:04:25:b5:3a:00:8e 20:01:00:25:b5:30:01:8f
                               [MCDBWS0200hba0]
    port-channel 10  510   0x860429  20:01:04:25:b5:3a:00:9e 20:01:00:25:b5:30:01:9f
                               [MCDBWS0201hba0]
    port-channel 10  510   0x86042a  20:01:04:25:b5:3a:00:7e 20:01:00:25:b5:30:01:7f
                               [mcvhes0118hba0]
    port-channel 10  510   0x86042b  20:01:04:25:b5:3a:00:af 20:01:00:25:b5:30:01:af
                               [mcvhes0116hba0]
    port-channel 10  510   0x86042c  20:01:04:25:b5:3a:00:6e 20:01:00:25:b5:30:01:6f
                               [mcvhes0117hba0]
    port-channel 10  510   0x86042d  20:01:04:25:b5:3a:00:4e 20:01:00:25:b5:30:01:4f
                               [mcvhes0119hba0]
    port-channel 10  510   0x86042e  20:01:04:25:b5:3a:00:5e 20:01:00:25:b5:30:01:5f
                               [mcvhes0120hba0]
    port-channel 10  510   0x860431  20:01:04:25:b5:3a:00:2e 20:01:00:25:b5:30:01:2f
                               [awotorprodsql01hba0]
    port-channel 10  510   0x860432  20:01:04:25:b5:3a:00:3e 20:01:00:25:b5:30:01:3f
                               [awotorprodsql02hba0]
    port-channel 10  510   0x860435  20:01:04:25:b5:3a:00:fe 20:01:00:25:b5:30:00:ef
                               [dbcactv01n3hba0]
    port-channel 10  510   0x860436  20:01:04:25:b5:3a:00:de 20:01:00:25:b5:30:00:bf
                               [dbcactv01n4hba0]
    port-channel 10  510   0x860439  20:01:04:25:b5:3a:00:ce 20:01:00:25:b5:30:00:8e
                               [mcvhes0123hba0]
    port-channel 10  510   0x86043a  20:01:04:25:b5:3a:00:be 20:01:00:25:b5:30:00:af
                               [mcvhes0122hba0]
    port-channel 10  510   0x86043c  20:01:04:25:b5:3a:00:ae 20:01:00:25:b5:30:00:9e
                               [mcvhes0124hba0]
    port-channel 10  510   0x860443  20:01:04:25:b5:3a:00:8d 20:01:00:25:b5:30:00:6e
                               [mcvhes0125hba0]
    port-channel 10  510   0x860445  20:01:04:25:b5:3a:00:ee 20:01:00:25:b5:30:00:cf
                               [mcvhes0121hba0]
    port-channel 10  510   0x860446  20:01:04:25:b5:3a:00:9d 20:01:00:25:b5:30:00:7e
                               [mcvhes0126hba0]
    port-channel 10  510   0x860447  20:01:04:25:b5:3a:00:6d 20:01:00:25:b5:30:00:4e
                               [mcvhes0127hba0]
    port-channel 10  510   0x860449  20:01:04:25:b5:3a:00:7d 20:01:00:25:b5:30:00:5e
                               [mcvhes0128hba0]

    I think what you do is F-Port trunking channeling !
    port-channel as a zone member ? I assume you will do pwwn based zoning; in which case the answer is NO !

  • Design help related to ACE to Switch connectivity using Port-Channel

    Hi,
    I have a Cisco ACE 4710 configured in One-Arm mode. This ACE is getting connected with 2 3750 switches. These 2 3750 switches connected in trunk mode.
    ACE is connected to these 3750 switches using Port-channel.
    ACE Config:
    ================================
    interface gigabitEthernet 1/1
      description One-arm mode port to DMZ Switch 1 port 20
      channel-group 1
      no shutdown
    interface gigabitEthernet 1/2
      description One-arm mode port to DMZ Switch 2 port 20
      channel-group 1
      no shutdown
    interface port-channel 1
      switchport access vlan 51
      port-channel load-balance src-dst-ip
      no shutdown
    interface vlan 51
      ip address 10.40.56.131 255.255.255.128
      access-group input everyone
      access-group output everyone
      nat-pool 1 10.40.56.215 10.40.56.215 netmask 255.255.255.255 pat
      service-policy input LB
      service-policy input remote-access
      no shutdown
    ===========================================================
    The problem is that 3750 switches are not stacked.
    Application is working fine. But i am getting a lot of MAC flapping messages..
    kindly suggest whether this design is OK or something needs to be done to rectify it...
    Attached a small diagram..

    Hello acharyr123,
    I don't think this design is ok, and it would cause mac flapping since the two indepedendent 3750 switches will learn the ace mac addresses off of two different interfaces.  The 3750s would have to be stacked so that they would act as one switch then this should work correctly.
    Thanks
    Joel Lamousnery
    TAC CSE

Maybe you are looking for

  • Help needed in sap script

    Hi friends, I`ve assigned the script name and driver program in NACE tcode for ME21N transaction. When I print preview from ME21N tcode and keep script debugging active it goes into debugging mode ...Here it shows script name same as what has been as

  • Cloud service with iTunes - how does it work?

    May I use "cloud" service to storage my podcasts? (http://selectel.ru/services/cloud-storage/) iTunes doesn't see the link (Bad http error 502)

  • Issues syncing photos to the new iPad

    I just got the new iPad and wanted to transfer all my pictures and videos from my windows 7 toshiba laptop. I connected with the setting sync all photos including video checked. The sync wouldn't transfer all photos and kept missing one album and non

  • Having problem with Solaris LUN and New disk

    Hi All, I'm using Solaris server, SunOS 5.10 Generic_144488-08 sun4u sparc SUNW, SPARC-Enterprise. There is a newly created LUN of 250GB. I've scanned the system and able to see the new LUN. I've also checked the LUN size and it's confirmed having 25

  • I lost all my notes after having switched off in icloud: how to recover them from a back up pls ?

    I lost all my notes after having switched off in icloud: how to recover them from a back up pls ?