Hello HFM Group,
I need some quick guidance. There are 3 HFM accounts that I want to protect against FDM Exports
Three accounts I want to protect:Op_AirOp_VehOp_Tra
The Protection Operation is set at " = "
The Protection Value is set as: Op_Air; Op_Veh; OpTra
My problem seems to be that the protection value only works when I list 1 account in the Protection Value box. I.E. It will protect the Op_Air account if it's the only account listed. But if I list the 3 accounts delimited by a semicolon as shown above it doesn't protect any of them. Surely there is a way to specify multiple values WITHOUT having to designate a common UD1 for these 3 accounts in HFM?
Can't I list multiple values in the Protection Values box? If so what is the syntax to separate the values? Evidently, it's not semi-colon or comma....Any Ideas
FYI - I know I could designate a common UD1 and place them on all 3 of these accounts but I am trying to avoid this direction.
Thanks,
James

Hello,
Currently right now the FDM Data Protection option is limited to a single value.
The way the data is handled between the two software products is a current limiting factor.
Thank you.

Similar Messages

  • Data protection in FDM

    We're trying to set up data protection so that FDM doesn't overwrite manual input schedules but only replaces GL data. We've set up a C1 member called "Data_GL" to receive this data. The FDM manual reads as follows but offers no clues on how to set and use the settings and functionality. Any help on making this work will be gratefully received.
    Best,
    John
    From the FDM manual, Configuring Integration Settings:
    * Data Protection Switch—Enables FDM to protect data in the target system from being overwritten during data imports based on a specified protection value. Use this when data is entered into the target system through a method other than FDM. <Selected "Yes">
    * Protection Value 1—Stores the value used with the Data Protection Switch. It is the value that is not to be overwritten. Selected "Data_GL" - C1 member for storing GL data>
    * Protection Operator—Stores an operator (= or <>) to determine if items equal to the value stored in the Protection Value 1 are to be protected, or if items that do not equal the value stored in the Protection Value 1 are to be protected.
    <Selected "not equal signs" ... that is, protect everything that is not "Data_GL">

    I too have found the FDM manual does not provide detail on how to set up Data Protection functionality.
    Any tips?
    James

  • Enable data protection in the FDM application

    Hi All,
    I just added a custom member in HFM and I would like to enable data protection in the FDM application for the particular custom member. Can anyone tell me how to enable the data protection in the FDM application.
    Regards,
    Sanjeev

    Hi,
    There are options needed to be set for data protection in FDM.
    In Integration settings->Enable data protection, Protection value, Protection operator.
    Set these values and u can use data protection facility.
    You can also go through the forums for more understanding:
    1. Re: Data Protection Switch - FDM
    2. Data Protection
    Hope it helps!
    You can tag it as Answer/Helpful if your Q is answered.
    Regards,
    J

  • Data Protection Switch - FDM

    I am trying to find out how to enable/setup the Data Protection Switch in FDM.
    The FDM manual does not explain how to do it. It just mentions the feature.
    Can anyone tell me how to enable this? Trying to protect data in HFM from being erased upon FDM loads. Certain data is entered directly into HFM using Data Forms (this keeps getting "Replaced" when Upstream loads).
    Any tips would be greatly appeciated.
    James
    469-549-6154

    Good day James,
    The first requirement is that you have configured FM to have a custom dimension member that is valid for all accounts or the accounts that you want to protect.
    You only have one member that you can secure or all the other members but this one member in any dimension.
    The data protection has three switches that you need to activate to protect the data. To my knowledge this only works with FM. Because FDM extracts the data and attaches the data to the bottom of the data load
    1st Turn on the data Protection (Enable data protection)
    2nd Supply a protection value this is the name dimension member that you want to protect in FM (Protection values)
    3rd Choose your operator, this switch can be set to greater or smaller than not the current protection value as specified above or equal to the protection value which will only protect the members in the named dimension member and all other members in the dimension will be cleared with the replace.
    The best way to implement data protection is to allocate one custom dimensions and load all the General ledger data into a members GL member and the supplementary data into another member/s.
    Regards

  • Data Protection Switch

    Hi again,
    I'm teaching myself FDM so please bear with (probably not the best practice but gotta go with it.)
    I'm trying to learn more about the Data Protection feature and I can't seem to find much information in the Admin Guide other than where the switch is and what it is useful for. Can anyone point me in the right direction for more information on how to use it?
    Can the Data Protection feature be used to protect multiple accounts? What about specific account and custom intersections?
    An example would be awesome, but I understand if that's asking for too much.
    I'm using v11.1.1.3 with adapter 11x-G5-C
    Thanks for your time.

    Great presentation; I'm learning we are seriously underutilizing FDM.
    I didn't realize this feature would require metadata changes to HFM. I'm not sure about building these required changes into any of the custom dimensions since we already use them for multiple purposes.
    Please confirm my understanding of what happens. FDM extracts all records for that POV and searches the entire string for the Protection Value and if it finds it anywhere in the string then it appends it or deletes it (depending on the operator.) Is my understanding correct? Any dimension member can be used? Also, does it only extract for entities that are being loaded to?
    Hmmmm....wondering why this feature which seems so great in theory lacks the functionality to be used in practical environments...but I'm not a technical expert, what do I know.
    Any other tips are greatly appreciated.

  • FDM Data Protection does not work

    Hi experts,
    I am trying to implement FDM data protection. Here's the situation: In C4, we have 3 members - LSS, LSSGA, MI. I want to replace only the contents in LSS and preserve the manually entered data in LSSGA and MI members. When I enable data protection with <> "LSS", it works for once. There is a situation here where the data in LSS also gets modified occassionally. Following this, FDM Replace cannot replace the data in member LSS. Has anyone faced this issue before ?
    Else, how to enable protection for more than one values ?
    Any help is appreciated.
    Thanks,
    George

    You already have an issue from the details you have specified. If you are saving non 'LSS' records, i assume by setting the protection vaue as not equal to 'LSS', then it is going save the 'MI' records, but not the 'LSS' records AND the 'LSSGA' records (It will not save the LSSGA records because it includes the string 'LSS' and that is all the function looks for - it uses the VB Instr function.
    To save multiple strings from a single location would involve bespoke changes to the adaptor Export script, or revising your metadatanames so that changing the protection value string could cover multiple dimension names as you have with LSS and LSSGA.

  • FDM :  Error while checking Integration Settings

    Hi,
    I am in the process of setting up an FDM App (Version 9.3.1)) for loading data to Essbase.
    I've Imported and Registered ES9X-G4-A Adaptor via Workbench. I've also added the Machine Profile.
    When I try to test Integration Settings in the Web Client by 'Browsing for Target Value' in Maps, I get the following error:
    ERROR:
    Code......................................... 53
    Description.................................. File not found: esbapin.DLL
    At Line: 125
    Procedure.................................... clsBlockProcessor.ActConnect
    Component.................................... upsWBlockProcessorDM
    Version...................................... 931
    Thread....................................... 2668
    For the moment, I have mapped only 2 Dimensions. The peculiar thing is if within any Dimension, I check the 'Use List' Box, I get the above error, during Integration Check.
    But if I leave that box blank, I do NOT get an error, but only a 'No Items to display' box.
    Am I missing any steps? My feeling is the Adaptor has not been configured correctly.
    Kindly advise.
    Regards,
    Tejas.

    Hi,
    Thanks for that information.
    It was indeed the issue. When I installed the client, I could proceed.
    Now, I have a different issue. When I 'Export' data, I get the following error message.
    ERROR:
    Code......................................... 5
    Description.................................. Invalid procedure call or argument
    At Line: 523
    Procedure.................................... clsBlockProcessor.ActExport
    Component.................................... upsWBlockProcessorDM
    Version...................................... 931
    Thread....................................... 3884
    Any idea what this is about?
    Tejas.

  • Oracle Data Protection

    Can someone please point me in the right direction. Is there a difference between Tivoli Data Protection, Tivoli Storage Manager, and Oracle Data Protection. What I need to figure out what I need to get RMAN working with TDP. The environment is AIX R2 and Oracle 10g

    In short you need Data Protection for Oracle and Tivoli Storage Manager.
    Long explanation can be found in http://www.redbooks.ibm.com/abstracts/SG244877.html section "19.5.3 Using RMAN and Data Protection for Oracle "
    >
    Data Protection for Oracle does not provide a command line or GUI interface to manage backups and recovery of an Oracle database - instead, Data Protection acts as an interface between the RMAN API and the Tivoli Storage Manager API. In other words, it sends the data between these components, as shown in Figure 19-10. The RMAN command line or GUI interface is used to perform backup or database recovery.
    When Data Protection for Oracle is configured, all administrative commands (such as backup and recovery) take place entirely under RMAN control, so the Oracle DBA does not need to know Tivoli Storage Manager commands. RMAN settings or commands are also used to remove expired backups from Tivoli Storage Manager storage. This is because expiration of Oracle backups are not governed by Tivoli Storage Manager policy domain settings of the client. The Oracle objects are always stored in a backup copy group using a unique name, which eliminates the retention and versioning values in your backup copy group, as the Oracle objects are always considered as active from the Tivoli Storage Manager perspective.
    Data Protection for Oracle cannot be used to back up or restore non-database data, such as history files or other system configuration files. You should use the Tivoli Storage Manager backup-archive client to back up these files.

  • Using FDM to load data from oracle table (Integration Import Script)

    Hi,
    I am using Integration Import Script to load data from oracle table to worktables in FDM.
    i am getting following error while running the script.
    Multiple-step OLE DB operation generated errors. Check each OLE DB status value, if available. No work was done
    Attaching the full error report
    ERROR:
    Code............................................. -2147217887
    Description...................................... Multiple-step OLE DB operation generated errors. Check each OLE DB status value, if available. No work was done.
    At line: 22
    Procedure........................................ clsImpProcessMgr.fLoadAndProcessFile
    Component........................................ upsWObjectsDM
    Version.......................................... 1112
    Thread........................................... 6260
    IDENTIFICATION:
    User............................................. ******
    Computer Name.................................... *******
    App Name......................................... FDMAPP
    Client App....................................... WebClient
    CONNECTION:
    Provider......................................... ORAOLEDB.ORACLE
    Data Server......................................
    Database Name.................................... DBNAME
    Trusted Connect.................................. False
    Connect Status.. Connection Open
    GLOBALS:
    Location......................................... SCRTEST
    Location ID...................................... 750
    Location Seg..................................... 4
    Category......................................... FDM ACTUAL
    Category ID...................................... 13
    Period........................................... Jun - 2011
    Period ID........................................ 6/30/2011
    POV Local........................................ True
    Language......................................... 1033
    User Level....................................... 1
    All Partitions................................... True
    Is Auditor....................................... False
    I am using the following script
    Function ImpScrTest(strLoc, lngCatKey, dblPerKey, strWorkTableName)
    'Oracle Hyperion FDM Integration Import Script:
    'Created By:     Dhananjay
    'Date Created:     1/17/2012 10:29:53 AM
    'Purpose:A test script to import data from Oracle EBS tables
    Dim cnSS 'ADODB.Connection
    Dim strSQL 'SQL string
    Dim rs 'Recordset
    Dim rsAppend 'tTB table append rs object
    'Initialize objects
    Set cnSS = CreateObject("ADODB.Connection")
    Set rs = CreateObject("ADODB.Recordset")
    Set rsAppend = DW.DataAccess.farsTable(strWorkTableName)
    'Connect to SQL Server database
    cnss.open "Provider=OraOLEDB.Oracle.1;Data Source= +server+;Initial Catalog= +catalog+;User ID= +uid+;Password= +pass+"
    'Create query string
    strSQL = "Select AMOUNT,DESCRIPTION,ACCOUNT,ENTITY FROM +catalog+.TEST_TMP"
    'Get data
    rs.Open strSQL, cnSS
    'Check for data
    If rs.bof And rs.eof Then
    RES.PlngActionType = 2
    RES.PstrActionValue = "No Records to load!"
    Exit Function
    End If
    'Loop through records and append to tTB table in location’s DB
    If Not rs.bof And Not rs.eof Then
    Do While Not rs.eof
    rsAppend.AddNew
    rsAppend.Fields("PartitionKey") = RES.PlngLocKey
    rsAppend.Fields("CatKey") = RES.PlngCatKey
    rsAppend.Fields("PeriodKey") = RES.PdtePerKey
    rsAppend.Fields("DataView") = "YTD"
    rsAppend.Fields("CalcAcctType") = 9
    rsAppend.Fields("Amount") = rs.fields("Amount").Value
    rsAppend.Fields("Desc1") = rs.fields("Description").Value
    rsAppend.Fields("Account") = rs.fields("Account").Value
    rsAppend.Fields("Entity") = rs.fields("Entity").Value
    rsAppend.Update
    rs.movenext
    Loop
    End If
    'Records loaded
    RES.PlngActionType = 6
    RES.PstrActionValue = "Import successful!"
    'Assign Return value
    SQLIntegration = True
    End Function
    Please help me on this
    Thanks,
    Dhananjay
    Edited by: DBS on Feb 9, 2012 10:21 PM

    Hi,
    I found the problem.It was because of the connection string.The format was different for oracle tables.
    PFB the format
    *cnss.open"Provider=OraOLEDB.Oracle.1;Data Source= servername:port/SID;Database= DB;User Id=aaaa;Password=aaaa;"*
    And thanks *SH* for quick response.
    So closing the thread......
    Thanks,
    Dhananjay

  • Data Protection Manager 2012 R2 agent: SetDpmServer returns error 0x80004005

    I have a Windows Server 2008 R2 server running business-critical applications. This is an ancient server, and I don't know who and how installed and configured its OS. I need to protect it using DPM 2012 R2.
    I was unable to automatically deploy DPM agent to this server due to error, so I installed the agent manually. However, when I try to manually associate the agent with a DPM server, it returns the following error:
    C:\Program Files\Microsoft Data Protection Manager\DPM\bin>SetDpmServer.exe -dpmservername SERVER
    Configuring dpm server settings and firewall settings for dpm server =[SERVER]
    Configuring dpm server settings and firewall settings for dpm server =[DOMAIN\SERVER]
    SetDpmServer failed with errorcode =0x80004005, error says: To further troubleshoot failures with SetDpmServer, go to
    http://go.microsoft.com/fwlink/?LinkId=169142
    The link is invalid. I've found a Techne article mentioning this error code, which tells only to check access to the DPM server from the server with the agent. The agent does have access, but the error persists even if I turn off the firewall completely.
    I even reset the local firewall rules to default settings, but it has had no visual effect (except I had to restore several rules manually).
    I suspect that something is wrong with OS settings or services. Any ideas what can be investigated next?
    Evgeniy Lotosh<br/> MCSE: Server infractructire, MCSE: Messaging

    Hi
    If you add the following predefined default firewall rules, the setdpmserver.exe should run:
    Windows Management Instrumentation
    Remote Service Management
    File and Printer Sharing
    Hope this helps. Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread.

  • Data Protection Verification Stuck on Iomega StorCenter ix2-200

    Anybody can kindly advise how to handle this issue?
    When logging into the storage web management UI 2 weeks back, I saw below message:
    Verifying data protection configuration. Verification is 1% complete.
    Now it is still 1% only, so I am thinking something must be wrong even though my NAS looks still working fine.
    May I know how to deal with it?
    Thanks in advance!

    My device is ok now. The '...1%' message has gone after being stuck for weeks. There had been another data protection verification activity afterwards which completed quickly.
    From event log I could only see very brief info like:
    "9029","2014-08-29 10:49:37","","INFORMATION","Verifying storage data protection."
    but it does not provide any value...

  • Data Protection Manager Client

    Hello collegues,
    is there an option to install Data Protection Manager Client (not the agent itself) for DPM 2012/2012 R2? We need an option for clients to backup/restore their's data on demand with GUI interface. I saw such an application in DPM 2010, but can't
    see it in 2012 options fo installation.
    Regards

    Hi,
    Please see the below links that may assist you.
    https://technet.microsoft.com/en-us/library/jj628055.aspx      
    Note if needed:
    The administrator of a client computer must set the name of non-admin users who have to have permissions to perform end-user recovery of protected data of a client computer. You only need to add the registry entries on
    the client machines same as on DPM 2010.  The DPM 2012 DPMRA Agent should still honor the keys.
    To do this, the administrator must add the following registry key and value for each of these non-admin users. This is single key that contains a comma-separated
    list of client users. You do not have to add this key separately for each non-admin user. 
    Registry key:
    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Microsoft Data Protection Manager\Agent\ClientProtection
    REG_SZ: ClientOwners
    Value: Names of non-admin users. This should be a comma-separated list of user names without any leading or trailing spaces, as in the following example: domain1\user1,domain1\user2,domain1\user3 (and so on)
    Following blog provides detailed steps to configure DPM recovery permissions for users that are not members of the local administrators
    group:
    http://blogs.technet.com/b/dpm/archive/2011/05/10/how-to-configure-the-dpm-client-to-allow-non-admin-users-to-perform-end-user-recovery-of-dpm-protected-data.aspx
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to
    other community members reading the thread. Regards, Dwayne Jackson II. [MSFT] This posting is provided "AS IS" with no warranties, and confers no rights."

  • Protection Value

    Hello HFM Group,
    I need some quick guidance. There are 3 HFM accounts that I want to protect against FDM Exports
    Three accounts I want to protect:Op_AirOp_VehOp_Tra
    The Protection Operation is set at " = "
    The Protection Value is set as: Op_Air; Op_Veh; OpTra
    My problem seems to be that the protection value only works when I list 1 account in the Protection Value box. I.E. It will protect the Op_Air account if it's the only account listed. But if I list the 3 accounts delimited by a semicolon as shown above it doesn't protect any of them. Surely there is a way to specify multiple values WITHOUT having to designate a common UD1 for these 3 accounts in HFM?
    Can't I list multiple values in the Protection Values box? If so what is the syntax to separate the values? Evidently, it's not semi-colon or comma....Any Ideas
    FYI - I know I could designate a common UD1 and place them on all 3 of these accounts but I am trying to avoid this direction.
    Thanks,
    James

    Thanks Tony.
    Is it possible to list various accounts in the Protection Value? for example account xxx , yyy and zzz? Or alternatively, is it possible to protect all the accounts descendant of a certain parent?

  • Disable data protection

    I really need to disable data protection for my ipad, it is enabled and I cant change the button so it makes it that my ipad doesnt erase after 8 failed attempts. Also it doesnt let me disable my password. Please answer quick as I have kids who will probably enter password wrong at least 8 times and delete ipad I really need to disable. Thankyou

    If YOU know the passcode then it should let you turn it off.
    You can remove the passcode on the iPad by tapping on Settings->Passcode->Turn Passcode Off.  You will need to know the passcode to change this setting.
    If you have forgotten the passcode then you will have to erase & restore.  Follow the directions here:
    Forgot passcode for your iPhone, iPad, or iPod touch, or your device is disabled - Apple Support
    That being said, by leaving your iPad with no passcode, your kids could conceivably go into settings & add one of their own if you remove it. 

  • Windows 7 Pro x64 does not detect HP Mobile Data Protection Sensor (accelerometer)

    Hello there.
    I installed win7pro x64 yesterday and already came across a serious problem that makes my way of using the notebook a bit dangerous for my precious data.
    When I was working on HP-branded Vista 32bit (from recovery partition etc), there was a device called HP Mobile Data Protection Sensor together with HP ProtectSmart (or Protect Smart) software. In other words, the HDD accelerometer that parks HDD's heads when it "feels" it's falling or something, and software for it. It worked brilliantly.
    Until I decided to install Win7... Then, surprisingly after a driver-install failure and taking a look at the Device Manager I noticed that there's no such device! I checked it three times, looked at every device's property, even reinstalled Vista 32bit back - it showed again - and installed Win7 - not detected again. There's nothing that has Device ID's HPQ004! I remember people saying that after fresh Windows install, there were 6 unknown devices or more. I had only 5. [Fingerprint device, 3x MemCard reader and IR receiver]. There was no accelerometer... Also, when I try to install the drivers/software, the windows pops up:
    ProtectSmart Hard Drive Protection: with text Property.AccelerometerNotPresent
    and then another one saying something like Features were not installed because of installation error or unsupported feature.
    So now I'm stuck with a notebook that is unsafe to travel with, because the disk is no longer protected
    I already installed all the drivers available from HP page, even downloaded newest ones from Intel (chipset) etc.
    Is there a solution to this? Has anyone else encountered this problem?
    Windows 7 is officially out and available as RTM version, not beta, so I think HP should open support for it and release new drivers for win7! And most importantly, fix this issue ...
    This question was solved.
    View Solution.

    Well, thanks to myself, I fixed it. After some thinking I remembered that ACPI = BIOS-related. It appears that there is a problem with the newest (F16) BIOS.
    F.16 changelog is below:
      Version: F.16 A  (26 May 2009)       Fixes  
    Updates the Intel MRC Code to version 2.7.
    Updates the Intel AHCI OP ROM to version iSrc 1.20_E.0012 11252008.
    Updates the BIOS to support Microsoft Windows Vista Operating Systems with Service Pack 2 (SP2).
     I went back to version F.14 and... boom! New (unknown) device found And guess what, it's ACPI/HPQ0004... So now my HDD is protected again ^^ yay!
    I don't know which of these changes cause that, but it looks that that can be fixed.
    I'll go back to F.16 again to see if the device will disappear and then contact HP support on that case.
    EDIT: Well, F.16 breaks things again, so it's definetely a BIOS problem. Thanks for... umm... well... at least spread the word, guys I hope this helps if someone has the same problem.
    Message Edited by dark_skeleton on 08-22-2009 07:08 AM
    Message Edited by dark_skeleton on 08-22-2009 07:11 AM

Maybe you are looking for

  • Message to the user

    Hi , I need help on below requirement. We maintained batch managment and SLED for materials. System should send a message to the user when a particular material is not used morethatn 30 days ( Compare with posting date ) How to acheive this. Pl reply

  • Printer with Mac

    Recently purchased new Mac with OS Yosemite; since then print color was off so have now changed all four ink cartridges with no improvement (prints out pink for photos, text ok in black). Also, stated it needs paper and I've put the paper in and out

  • When i email a it is in 4 pages when they receive it?

    i fill out a form for my business and when it is emailed it arrives in 4 pages though its a single pages, help???

  • 250 emails per day and I'm not subscribed to the Forum anymore!

    The single ipod question I raised originally has been succesfully resolved, but I now regret ever having joined these Forums. I have cancelled my subscription but still get notification every day of updates - 247 today. Who in Apple do I conact to ge

  • Java.lang.IllegalStateException: Session already invalidated

    why do i get java.lang.IllegalStateException: Session already invalidated at weblogic.servlet.internal.session.SessionData.invalidate(SessionData.java:) when iam using bea 8.1 and not in bea 5.1 .. I dont get this exception when session timesout in b