Few Issues as a beginer on 'Variables' and  'Web Interface'

Very very new to BPS..
Dear Friends,
I have the following 2 issues ( Actually many.. but this post has restricted to only 2..   )
1) I have created a Characteristic 'Variable' with User Exit and filled by using FM ZXXXX to with some value on Planning Area. No syntax errors.. but looks like this has no affect (or) not triggered when I try to add some values from the 'Layout'??
Are varibles are for different use? (or) Am I missing anything?
2) I have generated WebInterface from a Planning Folder and when I tried to execute in the Web (using BPS_WB).. it showed an authorisation error..
HTTP 403 Forbidden error...
Can any one help me out?
Regards,
Hari

1) I just figured it out that 'The variable' has to be selected in the planning level to make it apply. I also noted that the FM is getting triggered..
I was just defaulting the varible with one value and saw in the debugger that it is doing that.. but that has no affect on the 'displayed' results or when I make new entries from the layout.. ?
can anyone try to explain me whats happening?
regards,
Hari
Message was edited by: Hari Kiran Y

Similar Messages

  • Cisco 4402 WLC IOS Upgradation using CLI and Web Interface

    Hi,
    I would like to know how to upgrade IOS of Cisco 4402 WireLess LAN Controller using CLI and Web interface ?
    Can any one help me regarding the same.
    Please answer as soon as possible.
    Thanks in advance.

    Here are the instructions for upgrading the controllers via GUI:
    http://www.cisco.com/en/US/docs/wireless/controller/release/notes/crn52.html#wp472449
    Instructions via cli:
    Cisco recommends that a direct CLI console port connection is used to update the controller software.
    1. Make sure a TFTP server is available for the Operating System (OS) software download. Also, keep these guidelines in mind when the TFTP server is set up:
    If a download is performed through the service port, the TFTP server must be on the same subnet as the service port because the service port is not routable.
    If a download is performed through the Distribution System (DS) network port, the TFTP server can be on the same or a different subnet because the DS port is routable.
    The TFTP server cannot run on the same computer as the Cisco Wireless Control System (WCS) because WCS and the TFTP server use the same communication port.
    2. Download the desired OS software update file from the Cisco website to the default directory on the TFTP server.
    3. Log into the WLC CLI.
    4. Issue the ping server-ip-address command to verify that the WLC can contact the TFTP server.
    5. Issue the transfer download start command and answer n when prompted to view the current download settings.
    This example shows the command output:
    transfer download start
    Mode........................................... TFTP
    Data Type...................................... Code
    TFTP Server IP.................................
    xxx.xxx.xxx.xxx
    6. TFTP Path...................................... TFTP Filename.................................. AS_2000_3_0_x_x.aes --OR-- AS_4100_3_0_x_x.aes --OR-- AS_4400_3_0_x_x.aes Are you sure you want to start? (y/n) n Transfer Canceled Issue these commands to change the download settings:
    * transfer download mode tftp
    * transfer download datatype code
    * transfer download serverip tftp-server-ip-address
    * transfer download filename filename
    * transfer download path absolute-tftp-server-path-to-file
    Note: All TFTP servers require the full pathname. For example, in Windows, the path is C:\TFTP-Root. (In UNIX forward slashes (/) are required.)
    7. Issue the transfer download start command to view the updated settings, and answer y when prompted to confirm the current download settings and start the OS code download.
    This example shows the download command output:
    transfer download start
    Mode........................................... TFTP
    Data Type...................................... Code
    TFTP Server IP.................................
    xxx.xxx.xxx.xxx
    TFTP Path......................................
    path>
    TFTP Filename..................................
    AS_2000_3_0_x_x.aes --OR--
    AS_4100_3_0_x_x.aes --OR--
    AS_4400_3_0_x_x.aes
    Are you sure you want to start? (y/n) y
    TFTP Code transfer starting.
    TFTP receive complete... extracting components.
    Writing new bootloader to flash.
    Making backup copy of RTOS.
    Writing new RTOS to flash.
    Making backup copy of Code.
    Writing new Code to flash.
    TFTP File transfer operation completed successfully. Please
    restart the switch (reset system) for update to complete.
    8. The WLC now has the code update in active volatile RAM, but the reset system command must be issued to save the code update to non-volatile RAM (NVRAM) and reboot the WLC.
    This is a sample output:
    The system has unsaved changes.
    Would you like to save them now? (y/n) y
    The controller completes the bootup proce

  • Assign User Profiles and Web Interface Transactions to Users

    Hi EM Gurus,
    Has anyone worked with not standard scenarios in SCEM?
    They are working well but I can't access them on interface web.
    In selection page (search page after logon), where choose tracking scenarios, only standard scenarios appear although I have assigned both scenarios to the user and made same configuration; Assigned and Defined Web Interface Transactions, Configured Fields for User Profiles, Defined User Profiles, Assigned User Profiles and Web Interface Transactions to Users.
    But only Standard Scenarios appear as choice of tracking scenarios that are displayed to the user as a dropdown box on the selection screen after logging on to the Web interface.
    Has anyone accessed not standard scenarios on interface web??
    Help, please!
    Thanks a lot.
    Rodrigo Freitas

    Hello Rodrigo,
    if you have assigned the scenarios to your user in transaction /SAPTRX/UCUSER you must go to the admin page and reload the profile manager.
    /admin in the URL of the WCL instead /ehsearch.
    Afterwards you should see them also in the drop-down box.
    Best regards,
    Steffen

  • BW-Query with hierarchy variable and webi-prompt

    Hi,
    I think I've got a quite simple question.
    I've got a SAP-BW-Query and a hierarchy variable, and some none hierarchy variables.
    All Variables work in the webi-prompt.
    For the none hierarchy variables I've got the chance to search for values in the LOV, but I can't search for
    values in the hierarchies.Can I enable this function to search?
    Kind regards
    Lars

    Hi
    I post the error once again. I made an easier query and i saw that last time the forum did some strange things.
    A database error occured. The database error text is: Die MDX-Abfrage
    SELECT { [Measures].[DC59N8GR349ETCCV3ZHIFFWGC] } ON COLUMNS
    FROM [ZTESTM01/Z_ZTESTM01_TEST5_VARIABLE]
    SAP VARIABLES [!V000002] INCLUDING [0FISCPER].[V62009001]
    konnte nicht ausgeführt werden. Fehler Specify a value for variable
    MMEP_FISCPER. (WIS 10901)
    The query runs perfect in RSRT.
    When i put the statement
    SELECT
    { [Measures].[DC59N8GR349ETCCV3ZHIFFWGC] } ON COLUMNS
    FROM [ZTESTM01/Z_ZTESTM01_TEST5_VARIABLE]
    SAP VARIABLES [!V000002] INCLUDING [0FISCPER].[V62009001]
    in MDXTEST, it gives a result.
    Best regards,
    Florian

  • Range of Variable in Web Interface Builder

    Hi,
    I have created a Web Interface Builder in BW-BPS. I have created Cost Center as a Variable. However, I am unable to get this range of cost centers say 1001 to 1005 in Web Inteface Builder.
    Whereas, in the Planning Folder, this works fine and I am able to select the range of Cost Centers from 1001 to 1005.
    The issue is only with WEB INTERFACE BUILDER.
    Looking forward for some valueable inputs.
    Regards,
    Ravi

    Hi Mayank,
    Thanks for your reply.
    I will also look at the different options given.
    I also found the following thread is more useful.
    BSP Value Help Input Field and Select-Options Ranges
    I will let you know on this.
    Regards,
    Ravi

  • User-Specific Variable in Web Interface

    I have created a manual planning layout with User-Specific variables – one for Sale Group and one for Sales District.
    The variable successfully restricts user access to data when executed in SAP GUI.
    A Web Interface was successfully generated from the Planning Folder containing the manual planning layout described above.
    When I execute planning via the web, all possible values are displayed, even though the User-Specific variable limits this user to a single value for each variable.
    Is there a way to restore the restriction defined in the User-Specific variable ?
    I saw an earlier thread indicating that the “Planning Level” property of the Selector Variable Value for each variable used in the Web Interface Builder had to be set - but that field is protected from input.
    Any insights would be appreciated !
    Thanks,
    Lyle

    Narasimha,
    Each variable was created as :
    -     Replacement Type = User-Defined Values.
    -     Restriction of Values required by User = OFF.
    -     Input Allowed by User = OFF.
    Several users are defined within each variable.
    Most users represent Sales Representatives, with a single value assigned to each – a single Sales Rep is assigned a single Group and District ( i.e one-to-one relationship ).
    The other type user represents a Sales Manager, and includes all the values assigned to the Sales Reps reporting to him.
    When Restriction functionality is turned on, the following error message is received :
    Restrict variable UDSALDST (Sales District - User-Defined) (area ZBILLIC (IC Billings Estimate)) to single value
    <b>Diagnosis</b>
    Variable UDSALDST (Sales District - User-Defined) (planning area ZBILLIC (IC Billings Estimate)) is defined so that the user must restrict the values of the variable (indicator 'Restriction of values required by user' is set). However, you have not defined a restriction.
    <b>Procedure</b>
    Restrict the variable or change the definition of the variable so that restriction is no longer required.
    •     To restrict the variable, choose Goto -> Set variables and search for variable UDSALDST (Sales District - User-Defined) in the list. Make the restriction and subsequently continue the planning session.
    •     To change the variable definition, choose the tab page Variables in the context of planning area ZBILLIC (IC Billings Estimate) and reset the indicator 'Restriction of values required by user'.
    While the first option ( Goto > Set Variables ) seems to defeat the purpose of a User-Specific variable, I tried it.  When I use F4 to determine available values, it displays those previously assigned when creating the User-Specific variable !? – this doe not seem to add any more than I already have.
    The second option effectively puts me back to where I was when I posted the question.
    Of interest though, I noticed when the Restriction functionality was turned on, the “All” value previously displayed as available for selection was no longer available – but the specific values for each of the other Sales Reps continue to be reflected, and this user can select values related to another Sales Rep..
    As mentioned in my original posting,
    I saw an earlier thread indicating that the “Planning Level” property of the Selector Variable Value for each variable used in the Web Interface Builder has to be set – but that the field is protected from input.
    Should this object property be ‘open’ to permit input ?  If so, is there a step or setting that needs to be performed.  Could authorization be an issue ?
    Thanks,
    Lyle

  • To retreive the data based on input in a variable in web interface.

    Hello all,
    I am working on BW-BPS.
    I have a web interface which has many variables.One of them is Version.
    I fill in the values in the variables(including the version) and save the data.
    This saves the plan data in the Infocube.
    Now next time the user opens the web interface.when he enters the version which is existing in the cube,then
    all the variables should get filled in with the values in the cube for that particular version.
    how do i achieve this??I mean how do i code this in the BSP page of my web interface.
    I have read about methods for redefinition in the class CL_UPWB_BSP_APPL.but do not know much about this.
    Regards,
    Dhanya.

    hi,
    you have to create a sub class of CL_UPWB_BSP_APPL i.e(create a class whose super class is CL_UPWB_BSP_APPL).
    since the BSP Event Handlers are implemented in it
    you can change accordingly.
    check this for enhancement for web interface:
    http://help.sap.com/saphelp_nw2004s/helpdata/en/62/e5a562753511d5b3d70050dadfb23f/frameset.htm
    regards,

  • Few issues with Qosmio G30-179 - remote and TV

    Hello, (I'm French and my English is bad)
    I have a Qosmio G30-179 and I can't use my remote when the computer is power on. But I can use the remote for turn power on my computer and I can use it when I use the TV or Media buttons (at the right of the power button.)
    Other problem: I don't receive anything when I seek a TV signal on Media player. Even if I'm in a place where I've already receive all TV channels. Maybe there are others problems undetected...
    All these functions have already worked and I realized they don't work little time ago. But I didn't use them for a long time ago, since I received my computer when it returned guarantee (I send it because it had a problem at RAM bars.)
    Then I think there was a problem with the support service. But I'm not sure.
    What do you think about it? Must I call them?
    Or this problem can be resolve easily?
    Thank you in advance.

    > All these functions have already worked and I
    > realized they don't work little time ago. But I
    > didn't use them for a long time ago,
    If all those functions are worked before I recommend you to use delivered recovery DVD and install OS again. After doing this your notebook will have factory settings again and, I hope, everything should work again as before.
    Try it!

  • Issue with Feature Deployment when DB and Web Server are on different machine

    Hi,
    We are trying to deploy our Custom Processes as site feature.
    In Visual studio it shows Deployment Succeeded but feature is not available in Site features.
    when we checked “Central Administration -> Manage Farm Solution” it shows below error.
    Web Server : The solution was successfully deployed.
    DB Server IP : Elements of type 'Receivers' are not supported at the 'Farm' scope. This feature could not be installed.
    DB Server IP : Elements of type 'Receivers' are not supported at the 'Farm' scope. This feature could not be installed.
    We are able to ping DB server from Web Server .
    Also , we are able to add custom fields and lookup manually in web Server and those are getting reflected in DB .
    Thanks,
    Abhijit

    Hello,
    I would probably post this in the SharePoint forum as deploying features is a SharePoint process and not Project / Project Server (even if the feature is related to Project Server).
    Paul
    Paul Mather | Twitter |
    http://pwmather.wordpress.com | CPS |
    MVP | Downloads

  • Freeserve/Orange POP3/SMTP and Web interface not recognising credentials

    Is there an outage on the email?I was getting my mail fine a couple of hours ago, but now I'm getting the message from my mail client (current Thunderbird) "Sending of password for user arkhamroad.fsnet.co.uk did not succeed. Mail server pop.orangehome.co.uk responded: Invalid login or password" and on the website (https://web.orange.co.uk/id/signin.php?rm=StandardSubmit) Sorry, the details you entered weren't recognised. Please try again.
    Have you changed your password recently? Please note that it can take up to four hours for your password to be changed on our systems, so you may need to try again later. The password change portal doesn't recognise my account details either Since I've not changed my p-word, I'm stumped.

    rodonn wrote:
    My wife, who also has an FSNET acct isn't having a problem.
    Curiouser & Curiouser! Nor is my wife. I even added my email a/c in her mail client under her Windows user with exactly the same server settings except the POP3 Account Name and it still didn't work.
    The only diff between our email accounts is mine is freeserve.co.uk and hers is orangehome.co.uk. However hers was acquired originally as a PAYG dial-up a/c. Was your wife's? My email came from with my ISP service. I have since changed my email pwd to be different from my BB pwd, which cannot be changed. I did wonder whether the POP3 server has reverted to my original = BB pwd but that still doesn't work.
    More curiosities: As you say sending still works, and is received at recipient. I nowadays send on SMTP 587 which is authenticated as the same as the incoming mail server. So the SMTP accepts the pwd that POP3 rejects!

  • LMS and Web interface

    Have LMS 4.0 a web interface for remoute control?

    Yes,
    LMS do have web interface (GUI) that wil allow you do different task like backing up the configuration of the devices, upgrading IOS, monitioring device proactively, viewing topology of your network, possible almost everything that do exist in the domain of Network management.
    To know more about it, kindly visit the below URL :-
    www.cisco.com\go\lms
    Hope it helps,
    Many Thanks,
    Gaganjeet

  • Web Interface Builder & Variable???

    Hi,
    Can someone help me to resolve this two issues.
    I try to create variables by using web interface builder.
    <b>1)</b>The variable- company code-<b>US100, CA100</b> are only ones I use in the selection of my planning leveL. <b>However, it shows all possible entries for the variable-company code</b> when I added the variable-company code in the web interface builder.
    <b>2)</b>Another variable-forecast year, I created it in the planning area (using 'fiscl year') and try to add this variable in the web interface builder and got <b>an error message-the selection to 0fisclyear is not 'restricted'.</b>
    Advices are appreciated.
    J.

    1) Set "Planning level" property of selector for you variable in web interface builder
    2) Restrict fiscal year

  • What is the diff b/w Abstract class and an interface ?

    Hey
    I am always confused as with this issue : diff b/w Abstract class and an interface ?
    Which is more powerful in what situation.
    Regards
    Vinay

    Hi, Don't worry I am teach you
    Abstract class and Interface
    An abstract class can have instance methods that implement a default behavior. An Interface can only declare constants and instance methods, but cannot implement default behavior and all methods are implicitly abstract. An interface has all public members and no implementation. An abstract class is a class which may have the usual flavors of class members (private, protected, etc.), but has some abstract methods.
    Edited by SASIKUMARA
    SIT INNOVATIONS- Chennai
    Message was edited by:
    sasikumara
    Message was edited by:
    sasikumara

  • BEX User exit variables in WEBI

    Hi Experts,
    Need your help please.
    I have a report in BEX with a user exit variable wich depends on other manual input variable.
    In BEX it works properly but in WEBI it doesn't recognize the user exit variable.
    It displays the error message: Not possible to determine the value for ZPD_YEAR_DAY variable
    Error in DB.​ ​Error message is​:​ ​failure to execute the query ​M​D​X​ ​S​E​L​E​C​T​ ​ ​{​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​F​E​O​H​J​3​T​3​2​H​4​Q​D​Z​4​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​D​H​9​K​1​N​I​T​C​Z​E​4​U​Y​3​J​4​U​A​E​T​Z​4​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​D​H​9​K​1​N​I​T​D​R​2​R​6​P​F​2​K​G​C​U​8​8​W​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​E​M​Z​V​7​C​H​J​M​V​2​A​Z​P​C​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​K​0​S​7​H​N​Q​B​O​5​J​A​R​L​S​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​G​6​D​3​U​V​4​M​I​3​7​5​S​8​W​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​H​P​Q​C​I​D​R​P​D​B​C​0​K​S​G​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​I​H​E​Y​U​5​3​8​S​X​E​F​Z​2​8​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​D​H​2​8​D​W​V​F​6​7​4​2​E​6​4​Z​O​L​8​F​X​3​4​]​ ​}​ ​ ​O​N​ ​C​O​L​U​M​N​S​ ​,​ ​N​O​N​ ​E​M​P​T​Y​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​ ​{​ ​[​0​C​A​L​Y​E​A​R​]​.​[​2​0​1​0​]​ ​}​ ​,​ ​ ​{​ ​[​0​H​A​P​_​D​O​C​_​I​D​_​_​Z​A​P​_​S​U​B​S​T​]​.​[​5​0​]​,​ ​[​0​H​A​P​_​D​O​C​_​I​D​_​_​Z​A​P​_​S​U​B​S​T​]​.​[​7​0​]​ ​}​ ​ ​)​,​ ​[​0​I​N​F​O​P​R​O​V​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​Z​D​A​T​E​_​A​T​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​ ​{​ ​[​Z​C​P​M​]​.​[​X​]​ ​}​ ​ ​)​,​ ​[​Z​P​R​O​M​O​C​A​O​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​Z​R​E​S​P​_​A​V​L​_​_​Z​N​I​V​_​C​A​R​R​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​Z​R​E​S​P​_​A​V​L​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​Z​N​I​V​_​C​A​R​R​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​0​E​M​P​L​O​Y​E​E​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​ ​D​I​M​E​N​S​I​O​N​ ​P​R​O​P​E​R​T​I​E​S​ ​M​E​M​B​E​R​_​N​A​M​E​,​ ​M​E​M​B​E​R​_​C​A​P​T​I​O​N​,​ ​[​0​E​M​P​L​O​Y​E​E​]​.​[​2​0​E​M​P​L​O​Y​E​E​]​,​ ​[​0​E​M​P​L​O​Y​E​E​]​.​[​4​0​E​M​P​L​O​Y​E​E​]​,​ ​[​0​H​A​P​_​D​O​C​_​I​D​_​_​Z​A​P​_​S​U​B​S​T​]​.​[​2​0​H​A​P​_​D​O​C​_​I​D​_​_​Z​A​P​_​S​U​B​S​T​]​,​ ​[​Z​R​E​S​P​_​A​V​L​]​.​[​2​Z​R​E​S​P​_​A​V​L​]​ ​O​N​ ​R​O​W​S​ ​F​R​O​M​ ​[​Z​A​V​D​P​_​M​0​1​/​Z​P​D​_​G​P​S​_​V​A​R​I​A​V​E​L​_​0​0​2​]​ ​ ​with error:​ Not possible to determine the value for ZPD_YEAR_DAY variable​.​ ​(​W​I​S​ ​1​0​9​0​1​)
    This ZPD_YEAR_DAY variable​ is the user exit variable.
    Thanks in advance,
    José Simões

    Hi!
    I am following up to this post to see if there is something I am missing.
    We have bex query with user exit variable and webi bi4sp04.4
    In bex the user exit variable works correctly, in webi, it is ignored  (the webi results are not filtered as they are in bex web results)
    I have tried moving the variable to the char restrictions and removed ready for input - so there are now no prompts in bex query.
    I have reviewed note 1611185 as well as other info on restrictions of BICS and webi, but cannot find a clear answer if bex user exit variables are supported in BI4 clients or not.
    Lee Lewis

  • Web Interface - "Execute function before displaying the layout" issue

    Hi Experts,
    In my project we have converted some BPS planning folder to Web interface. The steps are as below:
    1) Open the BPS planning folder using upspm. Copy the web interface as Web Enabled folder.
    2) Generate the web interface by clicking on go to --> Generate web interface
    3) Run transaction bps_wb. Open the web interface. Then generate web interface again
    4) Run the web interface by clicking on 'Display perview'
    5) In the web interface there are some some functions which get executed before displaying the layout.
    6) For such functions, push button gets created.
    7) I have set the visible property of such push button as false.
    8) Most of the time, when I am running the web interface, it
    is getting executed successfully.
    9) Some times, the web interface is not displaying the layouts successfully.In such cases I have observed that "Execute function before displaying the layout" is not working. Due to this some values like Fiscal Year is not getting set. So, the layout is not getting displayed.
    10) I understand that it may be due to compilation error.
    For example, I might have made some changes in the web interface. It must be saved and web interface must be regenerated before I diplay the interface again. Can you please help me in understanding the reason of this problem.
    11) Can you please help me understand the cause of point no 9. Is it a non-issue? What may be the reason that "Execute function before displaying the layout" does not work every time.
    Thanks

    Will a function that runs, before the data gets saved, work for you? You can configure such a function to run before the save command behind the save button you create in the planning application.

Maybe you are looking for