FI-CO interface error in billing
Hai Gurus
we are encountering an error while trying to generate accounting document in vf02. Following is the error
FI/CO interface: Balance in transaction currency
Message no. RW022
Diagnosis
The balances in transaction currency must be zero for each logical transaction when transferring to the FI/CO interface. A balance of " 4,412.00-" "INR" was determined for the logical transaction "".
System Response
The FI/CO interface does not process any transactions which have a balance in transaction currency other than zero.
Procedure
This is a system error of the calling application
We have checked other posts in SDN and confirmed that all recommended notes were already applied. We are facing this error only in our development and quality server. In production, no such error occurs
Hi Gino,
For each entry in your Excise Invoice, the Credit & Debit Account should be assinged in the below configuration.
IMG --> Logistics General --> Tax on Goods Movement --> India --> Account Determination --> Specify Excise Account per Excise Transaction
For your Excise transaction type, please check if you have the configuration for all the values in your 'Excise Invoice.'.
With Regards,
Karthik
Edited by: sapsd_123 on Jan 19, 2012 8:57 AM
Similar Messages
-
Hi All,
I am getting a RTP Interface error when i execute my RTP interface. Below is the error message-:
"Error X_WRTPOUT-ICODES in ISU_RTP_RTPRESVAL_CREATE when accessing RTP component &1 period &2"
This error message appears because i havent assigned any output parameters to my 'Default' RTP component code.
If i assign my ouput result code to my 'default' RTP component output then it works fine but then it does not work as per the requirement.
There is SAP note 1353441 for this error message and this is because of the SAP standard FM error. I have implemented this note in my system and still getting the above error message.
In RTP interface it is not necessary to assign any output parameters to 'Default' RTP component code because i have assigned output parameters to my other RTP comp codes.
Has anyone experienced this issue? Can anyone guide me with the resolution of this issue?
Thanks,
MayureshHi Christiane,
I get this error during billing execution using EA00 tcode. Also when i execute FM - ISU_RTP_INTERFACE_SINGLE_RUN to check my RTP interface output i get the same error message.
Below are the error details-:
Error X_WRTPOUT-ICODES in ISU_RTP_RTPRESVAL_CREATE when accessing RTP component &1 period &2
Message no. AJ532
Diagnosis
An access error occurred while an internal table was being read.
SAP Note-:
I have only applied SAP note 1353441 and havent applied 1378483 note.
I had a look at 1378483 note today and found that the correction for this note contains commenting the code that causes my above error. Hence i think that implementing 1378483 note should remove my error. I will ask basis guys to apply this note tomorrow and will update you about this.
Let me know what you think about this.
Thanks,
Mayuresh -
Account determination error in Billing
Dear Expert,
I create one billing doc(1840000318) based on SO:1810000296. But in the posting status it is showing "Posting document not created(account determn error) in billing. I did not found any FI relavant docs for this billing in open item customer list.
*Anyone can advice me why the FI docs not created automatically..???
**Do you think there any missing configuration set?
***Or if I cancel the billing docs then it will okay or not ?
Thanks & b.Rgds
BishnuHi Bishnu,
Check Points for Account Determination.
1. Ensure Cutomer master (Xd02)Sales Area Data- Billing Tab-- Acc Assign Grp ---Should be maintained
2. Material Master -
Sales Org-2----
Acc Assign Grp..Should be maintained.
3. In VKOA maintain
Application- V Chart of Accounts--Sales Org ---Acc Assgn Gp Of Cust -Acc Assgn Gp of Material-Acc Keys (ERL,ERS,ERF)----& G/L Account.
4. In ur Pricing Procedure i.e V/08... Maintain Reqt -2 corresponding to ERL,ERS,ERF. & Subtotal =9 in front of net total.
Revert for further clarification.
Regards
Amit Gupta -
Interface errors (crc, in/output, collisions etc.) via snmp
Hi,
I'm trying to understand how to get interface errors via SNMP. I do get stats via SNMP for ifInErrors / ifOutErrors etc, but I'm trying to get output via SNMP for the errors visible via the 'sh int x' command - CRC errors, input / output errors, collisions, runts. giants etc.).
1) The SNMP ifInError / ifOutError seems to give an overall counter of all errors from the time the device has started - Am I correct about this?
2) Is there any way I can get the interface-specific errors noted above via SNMP?
Thanks,
MarioDepends on the device and version of code, but most likely you will get what you want from the CISCO-IF-EXTENSION-MIB. Look at objects like cieIfInRuntsErrs, cieIfInGiantsErrs, and cieIfInFramingErrs. You will also get some ethernet-specific errors from the ETHERLIKE-MIB.
-
Is there an script that can monitor interface errors (input and output errors) and send an email out when it reaches threshold?
Thanks
Sent from Cisco Technical Support iPhone AppSure. Here's an example:
event manager applet error_monitor_GigabitEthernet0/1
event interface name GigabitEthernet0/1 parameter input_errors entry-op ge entry-val 5 entry-type increment poll-interval 10
action 2.0 cli command "enable"
action 3.0 cli command "show int GigabitEthernet0/1 | inc error"
action 4.0 mail server 10.1.1.1 from [email protected] to [email protected] subject "Errors on interface GigabitEthernet0/1" body "
Interface GigabitEthernet0/1 has seen $_interface_delta_value input errors in the past 10 seconds: $_cli_result" -
Open DeviceNet interface error when TestStand call VIs of NI PCI-8532
Hello,
We use NI PCI-8532 was used as DeviceNet master to do functionality test with a slave (AC Drive).
But when open DeviceNet interface, it happen the error.
We can't find the solution and hope to find help from you.
The basic sequence in TestStand is:
1). Call "Open DeviceNet Interface.vi" to open interface and creat interface object.
Interface(master) setting: interface name=dnet0, MAC ID=0, baudrate=125000bps
2). Call "Open DeviceNet IO.vi" to creat DeviceNet IO object.
Device(slave) setting: MAC ID=63
3). Call "Operate DeviceNet Interface.vi" and operation code=start
4). Call "Wait For State.vi"
5). Call "Read DeviceNet IO.vi" to read data from IO object
6). Call "Close Object.vi" to close IO object handle
7). Call "Close Object.vi" to close interface object handle
Remark, these DeviceNet VIs locates at "C:\Program Files\National Instruments\LabVIEW 2012\vi.lib\DeviceNet\VIAPI".
First time to run sequece in TestStand, it can pass to run step 1) to open DeviceNet interface.
But once there is some error with these steps, and it will happen "Open DeviceNet Interface" error (error code=0xBFF62006) when run these steps again.
Then even use LabVIEW DeviceNet example to test, and it happen the same error except restart computer.
The DeviceNet example locates at "C:\Program Files\National Instruments\LabVIEW 2012\examples\NI-Industrial Communications for DeviceNet\Basic Examples\PXI & PCI\MixedCommunication.vi".
Some information more:
PC operate system: Windows XP SP3
LabVIEW version: 2012 SP1
TestStand version: 2012 SP1
PCI 8532 driver version: 2.3.0
Other installed PCI board: PCI 8531 CANOpenThe following errors may be resolved by resetting the CAN, DeviceNET or LIN device:
Error -1074388986 occurred at ...
NI-CAN: (Hex 0xBFF62006) The object is already open in another application. Solutions: Ensure that only one application at a time uses an object , and that you close all objects prior to exiting your application (don't use LabVIEW toolbar's Abort button).
Error -1074388969 occurred at ...
NI-CAN: (Hex 0xBFF62017) This attribute's value must be provided prior to the Open. Solutions: Set the attribute using the Config function before the Open, and do not set the attribute at any later time; Do not configure multiple CAN Objects for the same ID.
SO,you should reset the DeviceNet.
And another similar issue can explain some points of your problem http://digital.ni.com/public.nsf/allkb/7D9383E9BEAD0B21862571640002F687?OpenDocument -
Error while billing document releasing to accounting.
Hi Experts,
Please give me possible reasons for below error while billing document releasing to accounting.
"Valuation with material cost estimate: error with product "500258045"
Message no. KE350
Diagnosis
In Profitability Analysis (CO-PA), the system tried to valuate a line item using the current standard cost estimate.
In order to determine the current plan period, the system needs to read the valuation segment of the material master.
The system has found that the current plan period is not filled forproduct "BDE98561002" in plant "9856".
Display material (View: Costing)
The system looked for the material cost estimate using costing key "ZK1", as defined in the Customizing settings for CO-PA.
System Response
The document cannot be processed.
Procedure
Contact your system administrator".
I have checked CKR1 transaction there were no cost estimates with KF costing status.
NOTE: Material Ledger Activated.
Please suggest the possible reasons and what to check?
Regards
Chandra.Check the cost estimate that is mentioned against the Costing key ZK1 whether it exists in the system and as you are saying there seems to be no cost estimate for the said material.
Hence release the std cost estimate for the said materia using CK11n or CK40n -
Can't burn CD's - "Interface error 5"
Hello, I haven't used my old firewire LaCie CD burner (LaCie 1394, blue front with the slide out tray) in a while but recently I needed to put some graphics files on a CD. The sw I'm using is Toast 6. No matter what I tyry to do I get the following message: "Interface Error: 5 The connection is not stable"
I tried different CD brands, no effect.
This is the setup.
Machine Name: Power Mac G4 Cube
Machine Model: PowerMac5,1
CPU Type: PowerPC 60? (1.1)
CPU Speed: 1.3 GHz
L2 Cache (per CPU): 512 KB
L3 Cache (per CPU): 2 MB
Memory: 1.25 GB
Bus Speed: 100 MHz
Boot ROM Version: 4.1.9f1
System Version: Mac OS X 10.4.2 (8C46)
Kernel Version: Darwin 8.2.0
Looking for answers I found an (unanswered) message on a macosx.com forum. I'm reposting it because it provides more info about the same problem:
[quote]
"Burning the disc failed because communication to the disc drive failed. (Error code 0x80020022)" -- Is the error code when I attempt to burn any disc using the Finder or Disk Utility.
"Interface Error: 5 The connection is not stable.
The drive reported an error:
Sense Key = Illegal Request
Sense Code = 0x210x02
BUFFER UNDERRUN" --
Are the errors when I attempt to use Toast Titanium v6.x and v7.x.
I'm using an iMac G5 running 10.4.2. I have two burners, both of which give me the errors and will no longer burn to CD's or DVD's (cheap or expensive media, I've tried many different types). The burners i have are an internal superdrive that came with the mac (MATSHITA DVD-R UJ-825) and an external LaCie Firewire DL drive (_NEC DVD_RW ND-3500AG). Both drives started giving this error at the same time and I can't think of anything that I installed that could effect these. I don't have any speed tools installed.
I have tried all that Apple suggests in the articles http://docs.info.apple.com/article.html?artnum=25750.
I've experienced the same errors twice before, though not both drives at the same time. What fixed it the first time was simply upgrading the firmware on the burner. Second time, there were problems on the hard drive that I was burning from (directory issues if i remember) and running a combination of Tech Tool and Disk Utilitity fixed that.
But this time, I'm at my wits end and can't find anything helpful online. I'm hoping to find an answer before I end up trying a complete system reinstall.
Any info would be greatly appreciated.
[/quote]
Yes, any info ...
TIA
Cube, 2 ibooks Mac OS X (10.4.2)I'm having the same problem using Toast 7 to burn a Video TS movie I made. I'm using an external Lacie 16X DVD-R DL drive and an iMac G5 2.0, and Mac OS 10.4.3
After several failures with Interface Error 5, I tried copying a DVD movie I made from another DVD. This was created with the same Lacie drive using Mac OS 10.3 and my old iMac FP 15 inch. I got the same failure message.
I then switched my Lacie Drive to the USB port and everything is working fine. I switched it back to FireWire and I get the same error message again.
I can play DVD's on the Lacie with either the USB or FireWire port without any problem, I just can't record using the FireWire port. The FireWire ports on the computer work fine with all my other FireWire devices.
It must be a combination of 10.4.3, Toast 7 and Lacie FireWire. I'm going to recheck Lacie's site to make sure I have all of the updates.
iMac G5 Mac OS X (10.4.2) Mac OS 10.4.3 -
Account determination error at billing level
Hi,
for Account determination error at billing level
i checked the line item level for the material by highlighting the item, then GO TO > ITEM > ITEM DETAILS. here 5 line items are there , 4 line items have same "Acct asgnmt grp" and 1 line item is different at order level. i gess this is the problem if am wrong please correct me.
thanks
Edited by: pandu123 on May 26, 2011 2:24 AM
Edited by: pandu123 on May 26, 2011 2:32 AMHi Pandu
A/c deterimation error. 1st you check in customer master sales area data billing tab page with account assingment and go to material master u select particular material see in sales organization 2 tab with account assignment. and go to T.Code VKOA check the combination which is assiged A/c assingmnet group of customer and matrial account assingment group. If it is not come goto VFX3 and specify the customer execute and click on RELEASE FLAG. If it is error go to log see the digonsis.
Kind Regards
Chandra Mouli A -
EEM interface errors not matching
I have the event applet configured below. I test by changing the controller time-slots to 1-15 instead of 1-24 in order to generate errors on my Serial0/1/0:0 interface. Errors are generated, but the eem applet does not match even though the errors are incrementing. I've turned on all suggested eem debugging and it shows 0 matches while I can see that the interface is incrementing the errors that should be triggering the actions from the eem.
configuration:
event manager applet multiple_if
event tag if_1 interface name Serial0/1/0:0 parameter input_errors_crc entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_2 interface name Serial0/1/0:0 parameter input_errors entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_3 interface name Serial0/1/0:0 parameter input_errors_frame entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_4 interface name Serial0/1/0:0 parameter input_errors_overrun entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_5 interface name Serial0/1/0:0 parameter output_errors entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_6 interface name Serial0/1/0:0 parameter output_errors_underrun entry-op ge entry-val 2 entry-type increment poll-interval 60
trigger
action 100 cli command "enable"
action 200 cli command "config t"
action 300 cli command "int Serial0/1/0:0"
action 400 cli command "description script worked!"
action 500 syslog msg "CRC failure leased line $_interface_name"
action 600 mail server "$_mail_smtp" to "$_mail_rcpt" from "$_info_routername@$_mail_domain" subject "ALERT: Serial Interface $id shutdown due to excessive interface error rate" body "\n$_syslog_msg"
action 999 end
debug ouput:
Jun 20 14:20:48 EDT: fh_fd_syslog_event_match: num_matches = 0
Jun 20 14:20:48 EDT: fh_fd_data_syslog: num_matches = 0
Jun 20 14:20:48 EDT: fh_fd_syslog_event_match: num_matches = 0
Jun 20 14:20:48 EDT: fh_fd_data_syslog: num_matches = 0
Jun 20 14:21:00 EDT: fh_fd_timer_process_async
Jun 20 14:21:00 EDT: cron_tick: num_matches 0
Jun 20 14:21:22 EDT: %HSRP-5-STATECHANGE: FastEthernet0/0.4 Grp 4 state Standby -> Active
Jun 20 14:21:22 EDT: fh_fd_syslog_event_match: num_matches = 0
Jun 20 14:21:22 EDT: fh_fd_data_syslog: num_matches = 0
Jun 20 14:22:00 EDT: fh_fd_timer_process_async
Jun 20 14:22:00 EDT: cron_tick: num_matches 0
Jun 20 14:23:00 EDT: fh_fd_timer_process_async
Jun 20 14:23:00 EDT: cron_tick: num_matches 0
Jun 20 14:24:00 EDT: fh_fd_timer_process_async
Jun 20 14:24:00 EDT: cron_tick: num_matches 0
output showing interface errors:
csc-lab01#sh int s0/1/0:0
Serial0/1/0:0 is up, line protocol is up
Hardware is GT96K Serial
Internet address is x.x.x.x/30
MTU 1500 bytes, BW 1536 Kbit/sec, DLY 20000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation PPP, LCP Open
Listen: CDPCP
Open: IPCP, loopback not set
Keepalive set (10 sec)
CRC checking enabled
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters 02:44:23
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: Class-based queueing
Output queue: 0/1000/0 (size/max total/drops)
30 second input rate 2000 bits/sec, 3 packets/sec
30 second output rate 2000 bits/sec, 2 packets/sec
9139 packets input, 1049231 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
224 input errors, 224 CRC, 117 frame, 95 overrun, 0 ignored, 81 abort
10737 packets output, 1511507 bytes, 0 underruns
0 output errors, 0 collisions, 15 interface resets
0 unknown protocol drops
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions
Timeslot(s) Used:1-24, SCC: 0, Transmitter delay is 0 flagsA few other things I noticed. Try this:
event manager applet multiple_if
event tag if_1 interface name Serial0/1/0:0 parameter input_errors_crc entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_2 interface name Serial0/1/0:0 parameter input_errors entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_3 interface name Serial0/1/0:0 parameter input_errors_frame entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_4 interface name Serial0/1/0:0 parameter input_errors_overrun entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_5 interface name Serial0/1/0:0 parameter output_errors entry-op ge entry-val 2 entry-type increment poll-interval 60
event tag if_6 interface name Serial0/1/0:0 parameter output_errors_underrun entry-op ge entry-val 2 entry-type increment poll-interval 60
trigger occurs 1
correlate event if_1 or event if_2 or event if_3 or event if_4 or event if_4 or event if_5 or event if_6
action 100 cli command "enable"
action 200 cli command "config t"
action 300 cli command "int Serial0/1/0:0"
action 400 cli command "description script worked!"
action 401 set syslog_msg "CRC failure leased line $_interface_name"
action 500 syslog msg "$syslog_msg"
action 501 info type routername
action 600 mail server "$_mail_smtp" to "$_mail_rcpt" from "$_info_routername@$_mail_domain" subject "ALERT: Serial Interface $_interface_name shutdown due to excessive interface error rate" body "\n$syslog_msg" -
Hi,
We have currently configured the VAT for higher secondary Cess and VF02 getting the Error in billing print preview and printing. for the higher secondary cess appears twice in the printing I have checked it in pricing procd.and also ine the Billing output.
But all configuration is fine there in Billing and Pricing Prod., help me solving this Error.
regards
Shashank.have a look to the print flag control in V/08 at condition level.
If it is ok, then ask to a developer to debug the printing program.
Regards
Roberto -
Can we set the Option "Show add-in user interface errors" with VBA?
Does anyone know if the advanced Option "Show add-in user interface errors" can be set with VBA in Project Pro 2013?
\Spiro Theopoulos, Montreal, QC (Canada)Spiro,
Sorry but as far as I know that option is not available through VBA.
John -
Help: Net.lib interface error
Hi!
I'm using the Palm Emulator to make a HTTP connection to my servlet. The same MIDlet works on my Palm, but when I run it on the emulator (in order to some screen captures), I get error mesg that says "Net.lib interface error: 0x0000120C", followed by java.io.IOException.
I've already set my proxy IP ...
Can someone pls help? TIA!
RgdsHi ....
Is anyone have any ideas to solved if this problem occur on the real palm m505 machine ??
Please advice and kindly reply
Thank
SL -
What types of Interface Errors lead to Input/Output Drops/Discards?
Hi All,
I was wondering if anyone knows if all of the following errors would lead to packet drops/discards.
Runts
Giants
Framing Errors
Overrun Errors
Abort Errors
Also, are there any types of interface errors that don't lead to packet drops/discards?
So if all interface errors lead to packet drops/discards, I may not have to poll for multiple OIDs for these errors, but instead just poll for packet drops/discards.
Any insight would be appreciated.
Thanks,
DavidifInDrops do not related to errors. In fact, ifInDiscards specifically count packets that were discarded without an associated error. This could be due to a lack of buffer space (e.g. no queue slot), or there was no listener for a TCP connection. The same is true for ifOutDiscards.
For a consolidated error count, look at ifInErrors and ifOutErrors. It will depend on the interface/encapsulation type as to what exactly will be counted as an error, but anything that would be an encap-specific error should appear in one of the interface error counters. -
I have 2 ACE appliances running in active/standby. On each appliance I have port 3 used for FT and port 4 used for server traffic. Every one of the connections terminates on a 3750 10/100 switch. The switch ports (all configured as access ports) are configured the same way and each of the connections from port 4 (the server port) works great with no interface errors. However, on BOTH ACE appliances, port 3, (the FT port) causes non-stop input errors and runts on the switch interface and failover will not work. I have tried to hardset the speed/duplex on both devices and every other possible combination with no success. AS A TEST ONLY --> When I plugged each of the FT interfaces into a $10 linksys hub, failover worked perfectly.
Since using the $10 hub is not an option, any ideas on what I can try to fix the issue?The FT interface is a trunk interface.
You have to set your switch to trunking mode not access mode.
This is explained somewhere in the documentation.
Gilles.
Maybe you are looking for
-
I'm trying to install a cd application and I keep getting the message 'you do not have permission to use the application FSP OS X' Even after selecting always allow and entering my login details it still won't accept it. Help!!..
-
Hi BW gurus, I'm trying to understand the code given in "How to extend master data to include SSN from R/3 HR" paper This is the part of of the exit routine to extend 0person_attr datasource... As I'm new to ABAP , I 'm having following questions ...
-
Can I place a html5 or flash video of a surfer in the header section?
I have been asked to build a home page with a video of a surfer riding a wave at a fun surfing location. We think it would be cool for the web user to come to the home page and right away watch a surfer catching a wave and riding accross in the video
-
Microsoft Reporting Services Portlet
Calling Joel, hross, Troy Rackley, Tim Larson , et al. I have the ReportViewer control in the portal, postbacks fail due to a Reserved.ReportViewerWebControl.axd URL gateway issue. I saw where some of you resolved this back in 08, but can't seem to f
-
Any way to stop rotating the surround sou
hey all im looking to buy one of those 3d head mounted displays with head tracking. so if you turn around physically, you turn around in the game. the problem is if you have physically turned 80 degrees, you are now facing the opposite direction to y