Hi All,
When i am trying to write data to file, it was opened by another person and it gave error in the receiver communication channel saying like source is using by another application. Which is well and good
But in case of Sender channel while writing the data to file even thought it is opened by another person, Sender file adapter is picked the file.
I didn't get the reason why it is like this. Any one of u had the same issue???
Regards

Hi Neetesh,
>>hmm ... that's weird ... you mean to say that the polling frequency is now (20 + 100) = 120 secs ? Unless and until the file is not being modified or the file is not "open", this parameter shouldn't work ...
Examples
Poll interval is 20 sec and MSecs to wait is 100000( 1 MIN 40 Sec)
1) If file is there and did not opened / modifying
waiting till 1 min 40sec to pick the file
2) If the file is there and Modifying it
Adapter is waiting 1 min 40sec if the files have been changed.
3) If there is a file and just opened, not writing any files
Waiting for 1 min 40 sec to pick the file
>>Can you share the adapter log?
Processing Details for Cluster Node Server 0 10_31463
     5/20/10 3:49:56 PM           Polling interval started. Length: 20.0 seconds
     5/20/10 3:49:56 PM           Processing finished successfully
     5/20/10 3:49:56 PM           Processing started
     5/20/10 3:49:56 PM            4f1e0c5b-9553-4397-30ef-d3bb55a13a48     Processing finished successfully
     5/20/10 3:49:55 PM            4f1e0c5b-9553-4397-30ef-d3bb55a13a48     Message with ID 4f1e0c5b-9553-4397-30ef-
                                               d3bb55a13a48 processed
     5/20/10 3:48:15 PM           Processing started
     5/20/10 3:47:55 PM           Polling interval started. Length: 20.0 seconds
     5/20/10 3:47:55 PM           Processing finished successfully
     5/20/10 3:47:55 PM           Processing started
     5/20/10 3:47:35 PM           Polling interval started. Length: 20.0 seconds
Regards
Edited by: Vamsi Krishna on May 20, 2010 10:50 PM

Similar Messages

  • File Adapter Write: Howto read partnerLinkBinding "logical path"-property?

    A process writes a file to a fileserver, and further down the process I'd like to publish the path+filename of the written file to an external partnerLink.
    I'm looking for something similar to ora:getPreference(), but instead reading a spesific partnerLinkBinding property not just the preferences-section property of bpel.xml.
    alternative 1) From within the BPEL-process I configure a logical path, but I can't see any api for reading that value (my property "OutBoundFiles").
    The value is read and used by the jca:operation within the FileWriter, and I supply a static value for it in the bpel.xml, like in:
    <partnerLinkBinding name="OutboundFileWriter">
    <property name="wsdlLocation">FileWriter.wsdl</property>
    <property name="OutBoundFiles">\\fileserver\OutboundDir</property>
    </partnerLinkBinding>
    alternative 2) The FileWriter wsdl OutboundHeader_msg has the one-and-only element "fileName", which also contains what I'm looking for.
    But I can't see how to read this element either, probably because the BPEL-team don't expose the value, due to the fact that they don't support writing to the element (there is no support for writing files to a dynamic path in version 10.1.2).
    Current workaround:
    Currently I use a preference property in which I copy the "OutBoundFiles"-value, and read it runtime using ora:getPreference(). Not a beauty.

    alternative 3)
    One could use a simple copy rule, by reading the bpel.xml-file:
    <copy>
    <from expression="ora:doc( 'bpel.xml', '/BPELSuitcase/BPELProcess/partnerLinkBindings/partnerLinkBinding[ @name = &quot;OutboundFileWriter&quot; ]/property[ @name = &quot;OutBoundFbFiles&quot; ]') "/>
    <to variable="emailpayloadUNCPath"/>
    </copy>

  • File Adapter Write Compilation problem JDev 11.1.1.6 and BPEL 2.0

    Hi,
    Im creating a simple BPEL Project with a One-way Process template project.
    I have added just one Partnerlink with a File Adapter to do a write operation.
    I have assigned the main process input to the file Write Invoke operation.
    But I am getting a compilation error.
    Error(81): inputVariable "inputVariable" of type "client:BPELProcessWriteToFileRequestMessage" is not compatible with WSDL message "ns1:Write_msg".
    Can you pl help ?
    Here is the BPEL syntax :
    <?xml version = "1.0" encoding = "UTF-8" ?>
    <process name="BPELProcessWriteToFile"
    targetNamespace="http://xmlns.oracle.com/FirstApplication/FileWriter/BPELProcessWriteToFile"
    xmlns="http://docs.oasis-open.org/wsbpel/2.0/process/executable"
    xmlns:client="http://xmlns.oracle.com/FirstApplication/FileWriter/BPELProcessWriteToFile"
    xmlns:ora="http://schemas.oracle.com/xpath/extension"
    xmlns:bpel="http://docs.oasis-open.org/wsbpel/2.0/process/executable"
    xmlns:ns1="http://xmlns.oracle.com/pcbpel/adapter/file/FirstApplication/FileWriter/WriteTextToFile"
    xmlns:bpelx="http://schemas.oracle.com/bpel/extension"
    xmlns:bpws="http://schemas.xmlsoap.org/ws/2003/03/business-process/"
    xmlns:xp20="http://www.oracle.com/XSL/Transform/java/oracle.tip.pc.services.functions.Xpath20"
    xmlns:oraext="http://www.oracle.com/XSL/Transform/java/oracle.tip.pc.services.functions.ExtFunc"
    xmlns:dvm="http://www.oracle.com/XSL/Transform/java/oracle.tip.dvm.LookupValue"
    xmlns:hwf="http://xmlns.oracle.com/bpel/workflow/xpath"
    xmlns:ids="http://xmlns.oracle.com/bpel/services/IdentityService/xpath"
    xmlns:bpm="http://xmlns.oracle.com/bpmn20/extensions"
    xmlns:xdk="http://schemas.oracle.com/bpel/extension/xpath/function/xdk"
    xmlns:xref="http://www.oracle.com/XSL/Transform/java/oracle.tip.xref.xpath.XRefXPathFunctions"
    xmlns:ldap="http://schemas.oracle.com/xpath/extension/ldap">
    <import namespace="http://xmlns.oracle.com/FirstApplication/FileWriter/BPELProcessWriteToFile" location="BPELProcessWriteToFile.wsdl" importType="http://schemas.xmlsoap.org/wsdl/"/>
    <partnerLinks>
    <partnerLink name="bpelprocesswritetofile_client" partnerLinkType="client:BPELProcessWriteToFile" myRole="BPELProcessWriteToFileProvider"/>
    <partnerLink name="WriteTextToFile" partnerLinkType="ns1:Write_plt"
    partnerRole="Write_role"/>
    </partnerLinks>
    <variables>
    <variable name="inputVariable" messageType="client:BPELProcessWriteToFileRequestMessage"/>
    </variables>
    <sequence name="main">
    <!-- Receive input from requestor. (Note: This maps to operation defined in BPELProcessWriteToFile.wsdl) -->
    <receive name="receiveInput" partnerLink="bpelprocesswritetofile_client" portType="client:BPELProcessWriteToFile" operation="process" variable="inputVariable" createInstance="yes"/>
    <assign name="Assign">
    <copy>
    <from>string('$inputVariable.payload/client:input')</from>
    <to>$inputVariable.payload/client:input</to>
    </copy>
    </assign>
    <invoke name="InvokeWriteTextToFile"
    partnerLink="WriteTextToFile" portType="ns1:Write_ptt"
    operation="Write"
    inputVariable="inputVariable" bpelx:invokeAsDetail="no"/>
    </sequence>
    </process>

    The error seen in your case typically occurs when the schemas of BPEL valriable and the schema of message in file adapter WSDL are different. You may use a transform activity in BPEL to map the fields of the two schemas.
    You may also like to have a look at various file adapter examples at
    http://java.net/projects/oraclesoasuite11g/pages/FileAdapters
    These samples provide working examples of how to handle various kinds of data when using file adapter.
    Regards.

  • How to combine both DAQ AI signal, write and read file in single VI

    Hi
     I am the new user of LabVIEW version 7.1 for testing automation application. I have to measure 33 signals ( mostly analog like temp, pressure, etc...) from NI USB 6210 DAQ system and write in master file for future verfication.From real data or from master file back up have to write  one more file if only the signal reaches steady state , which will used for analysis and same signals to be read from this file parallely & make a waveform and/or table display format.
    Pl. help me to shortout this problem 
    note: I have plan to ugrade labVIEW version 2011 shortly, so let me know doing parrel acquistion write and read file for data analysis in same VI in version 7.1...... 

    Parallel operations in LabVIEW are very simple.  Just code it in parallel and it will work.
    Try taking a look at some of the examples in the NI Example Finder (Help > Find Examples).  There you will find example for writing to and reading from files, as well as data acquistion in parallel with other operations.
    You might need a producer/consumer architecture is you are acquiring data very quickly.
    Chris
    Certified LabVIEW Architect
    Certified TestStand Architect

  • DAQ vi to perform digital write and read measurements using 32 bits binary data saved in a file

    Hi
    DAQ vi to perform digital write and read measurements using 32 bits binary data saved in a file
    Two main
    sections:
    1)     
    Perform
    write and read operations to and fro different spread sheet files, such that
    each file have a single row of 32bits different binary data (analogous to 1D
    array) where the left most bit is the MSB. I don’t want to manually enter the
    32 bits binary data, I want the data written or read just by opening a file
    name saves with the intended data.
          2)     
    And
    by using test patterns implemented using the digital pattern generator or  build digital data functions or otherwise, I need to
    ensure that the     
                binary data written to a spreadsheet file or any supported file type
    then through the NI-USB 6509 is same as the data read.
    I’m aware I can’t use the simulated
    device to read data written to any port but if the write part of the vi works I
    ‘m sure the read part will work on the physical device which I’ll buy later.
    My Plan
    of action
    I’ve
    created a basic write/read file task and a write/read DAQ task for NI USB 6509
    and both combine in a while loop to form a progress VI which I’m confuse of how
    to proceed with the implementation.
    My
    greatest problem is to link both together with the correct functions or operators
    such that there are no syntax/execution errors and thus achieve my intended
    result.
    This
    project is one of my many assignments for my master thesis, so please i’ll
    appreciate every help as I’m not really efficient with LabVIEW programming but
    I prefer it because is fun and interesting if I get to know it.
    Currently I’m
    practicing with LabVIEW 8.6/NI DAQmx 8.8 Demo versions and NI USB 6509
    simulated device.
    Please see
    the attached file for my novice progress, thanks in
    advance for the support
    Rgds
    Paul
    Attachments:
    DIO_write_read DAQ from file.vi ‏17 KB

    What does your file look like?  The DAQmx write is expecting a single U32 value, not an array of I64. 
    Message Edited by vt92 on 09-16-2009 02:42 PM
    "There is a God shaped vacuum in the heart of every man which cannot be filled by any created thing, but only by God, the Creator, made known through Jesus." - Blaise Pascal

  • Options for having cFP write and read file

    I have a cFP VI that runs on a cFP 2110 controller for doing process automation on a custom piece of equipment.  It seems that each month we use the same equipment for a slightly different automated process routine.  What I have done in the past is to make a copy of my VI's and real-time project and then make the changes in the code for the new process.  Most of the changes to the code between processes are just changes to numeric controllers to change ramp and slope times or the number of times the code repeats a set of steps.  I have been playing around with writing a sort of configurations page to my VI to allow the user to change some numeric controls, save them to a file using the Read Key.VI and Write Key.VI.  In the simple tests I have done, this works If I have a target VI on the cFP 2110 and a host VI where I can have the configurations page and save the file to my computer's hard drive. 
    The configurations file I would create would probably have 15-30 numeric controls and maybe some string commands.  I have a couple of questions about doing this.  Do I need to go back and create both Target and Host VI and communicate between the two using shared variables, or can I just keep my current VI and write a subVI that would save my files to the cFP controller?  If I save the files to the cFP controller, can user set the numeric controller and save the file and/or  likewise call-up any of say one of say 10 differnet files to populate the various sub-VI and run? 
    Finally, provided that I can write and read these small configuration numeric controller files to the controller, is there any advantage to writing the files to one method or the other: writing to the controller vs, creating a target and host VI to load the data?
    Thank you for the help. 
    Danny
    Attachments:
    Test read write key.vi ‏58 KB

    StepanieO,
    I finally had a change to play around with the cFP file write and read again.  I was able to write a the cFP and read the file back using write to spreadsheet and read from spreadsheet.  The one problem I can't seem to figure out is how you browse the cFP to select a file.  If I enter the file name and path into the string command it works.  But If I try to browse the cFP, the browse button only shows the computer hard drives.  Is there a way to browse the cFP controller for a specific file?
    Thank you for the help.
    Danny
    Danny
    Attachments:
    Write to spreadsheet.vi ‏18 KB

  • I want to write and read a hex file from the flash buffer of the microcontroller through the USB serial port

    hello sir,
    I am developing a GUI screen from that i want to write and read a hex file from the flash buffer of the microcontroller through the USB serial port. the driver i am using is FTDID2XX driver.if anyone having examples of loading file through serial port.Please reply me .
    Thanks

    Looks like you should post your request in the LabVIEW forum, this one here preferentially is for LabWindows/CVI...

  • Sender File Adapter is not reading anything

    Hi,
    I have a really strange problem here. I'm tyring to read a file using file adapter (FTP) and the adapter doesn't read anything and it does not throw any error in the communication channel monitoring.
    I'm using a receiver file adapter to write files to the same FTP folder, so it can't be a connectivity problem. And I tried to get the file using Filezilla and it works fine...
    In the sender file adapter I tried to simplify the maximum to solve the problem:
    - NO File Content Conversion
    - NO advanced attributes
    - I used the "*" in the file name to read any file
    - I've only configured the FTP connection, the folder and the file name. I don't understand why it isn't working...

    Yes I got this message:
    Polling interval started. Length: 5,0 seconds
    Now I tried something... In the FTP Connection parameters, I set as the server a random and unexisting name, and I get the same result...
    I'm starting to thing that some firewall is blocking the connection, but I have to wait until next monday to know this. But I don't understand why the receiver FTP channel is working...
    PD: The cache is correctly refreshed because I changed the polling interval time, and it has been updated on the monitoring

  • File Adapter Write missing files

    Hello
    I have some trouble with a bpel process containing a file adapter that should write files to disk. Each bpel-process is started when a read file adapter reads a new matching file (*.xml).
    I have tested the process with a few files (5-20) and a new process is started for each file, and at the end of the process a new file is written to disk by the file adapter (Write). But when I am testing with a large number of files (40-50 files) something strange happens.
    A new process is started for each file, but it looks like the file adapter that should write files to disk is not capable to handle the pressure. 10-20% of the processes doesnt complete as expected. In the BPEL Console everything looks ok, it seems like the File Adaper has written a file to disk, no error is trown. But when I look in the directory the file is not there...
    Has this something to do with performance? Is there any parameters or settings I can tune to make the file adapters work better? Sometimes it also looks like the file adapter (read) doesnt manage to start a new process for each incomming file even if they are deleted and archived...

    I ran into a similar issue. As a workaround we ended up just using java to write the files out. When the File Adapter attempts to write out a file it first writes that file to a temp file and then copies that to the appropriate directory.
    I believe that when two or more threads were attempting to write at the same time the write was failing for one (but appearing to work in the console logs). I think a race condition may be created when two threads attempt to write using the File Adapter for access to the temp file. I contacted my oracle rep about it but they are always pretty worthless so I havent ever heard anything back concerning the issue.

  • How can i write and read the same data

    hi,
             i have attached my program to this mail. i have some problems in this program.
    problems:
    1. I want to select the threshold for the rms,varience and s.d.
    But what i used is not doing that. i want to fix the upper threshold value and lower threshold value.
     when ever the input crosses upper threshold value i want the output and it will remains uptill the value above the lower threshold value.
    Once it come down the lower threshold value the output should be stopped.
    2. I want to write this in to a  file and i want to read this file. is this possible or not. 
                please try to help me i am very new with lab view6i
           REGARDS
    CHAMARTHY KOMAL DILEEP.
       [email protected]
    Attachments:
    dileep.vi ‏93 KB

    The easiest way to perform a certain action (such as file I/O) based on a certain condition (such as whether a value has passed a certain threshold) is to use a comparison VI in combination with a case structure. Then you can specify that if your rms, standard deviation and variance are above a threshold then perform a certain action.
    Also consider using shift registers to keep track of data from the last loop. If I understand you correctly, you want to start logging data when an upper threshold has been passed. Then you want to continue logging data until a lower threshold is passed. I have attached a non-functional but explanatory VI that will help explain how to implement logic to that effect. It also demonstrates that you can indeed write and read from the same file in a loop. The best way to do this is to open the file before the loop, do all the necessary writing and reading in the loop, and then close the file after the loop.
    Hope this helps!
    Jarrod S.
    National Instruments
    Attachments:
    dileep_example.vi ‏61 KB

  • NI 6602 Write and Read Frequency

    Hi all ,
    I Have NI 6602 timing card and i'm trying to use it in order to write and read using the
    DAQmxWriteCtrFreq (taskHandle1, 0, 1, 10.0, DAQmx_Val_GroupByChannel, &freq, &duty, &writtenVal, 0);
    and
    DAQmxReadCounterScalarF64(taskHandle2,10.0,&dataVal,0);
    what i'm trying to do is to write to ctt0 and to read from ctr7 ( they are crossed in the card )
    i'm having a bit problems with that can some one give me a tip on how to do it properly ?
    just write freq to ctr0 and read freq from ctr7.....
    Kobi Kalif
    Software Engineer
    Solved!
    Go to Solution.

    You should have the following sample installed on your PC that may help you in this task: DigPulseTrain-Cont.prj (it could be located in \program files\National Instruments\CVIx\samples\daqmx\counter\generate pulse folder)
    Proud to use LW/CVI from 3.1 on.
    My contributions to the Developer Zone Community
    If I have helped you, why not giving me a kudos?

  • File adapter didn't read the whole file

    Hi folks,
    we use the file adapter since 1 year and in the majority of cases it works fine. But sometimes the file adapter didn't read the whole file. In SAP we are missing some parts. Funnily enough in this cases he archive the whole file and not only the executed parts . Know anybody whats the reason of this effect and how we can solve it?
    Kind regards Johann M.

    Johann
    I think you miss understood me/I didn;t explain myself very well....
    If you take the file that doesn't work/process correctly, can you replicate the issue where the whole file is not copied across.
    If you can, you should be able to extend the FTP/File adapter trace file to find the cause if this issue.
    Log onto Visual Admin.
    &#61680;     Services
    &#61680;     Log Configurator
    &#61680;     Locations
    &#61680;     Choose the location (Java package) and the tracing level (severity)
    (for example, com.sap.aii.adapter.file)
    &#61680;     Root Location > com > sap > aii > File
    &#61680;     Set the severity and choose Copy Severity to Subtree
    Run interface and then check the trace file - remember to switch this back to Error...

  • File adapter unable to read file, can it call another BPEL process

    hi'
    I have a XML file to read and I am able to read it by using a File adapter, if the read is success the file is moved to success directory and if the file is invalid its going in the fail directory, now the question is If the file read is not valid at that moment can another BPEL process be invoked, becasue if the file read is invalid then the BPEL process dosent gets initiated due to which I am unable to do anything.
    please advice
    thanks
    Yatan

    Hi,
    You can use file rejection handler which can invoke a user defined BPEL process in case of invalid file. Check :
    http://www.oracle.com/technology/products/integration/adapters/pdf/Adapter_TN_004_Adapter_ErrorManagement.pdf
    HTH,
    Ketan

  • Closing a serial port after executing a for loop of write and reads.

    Hello,
    Labview is opening and then closing each write to the port. I have tried to leave the close outside of the for loop, but labview wont allow it. What do I need to change to make all the writes and reads execute on 1 open and close of the serial port.?
    Thanks.
    Attachments:
    Controller.vi ‏27 KB

    J_es--
         The program that you posted looks to be ok for the most part, you might consider putting an open after your configure (but that's trivial). The other thing that is a minor issue is the loop tunnel coming out of your for loop is currently being auto-indexed.  This function is used to index data for each interation of the loop.  You are using a static address (not an array) and so you don't need this.  If you right-click and remove the auto-index the broken wire will go away. Other than that it should be ok.
         I would suggest looking at one of the shipping examples that come with LabVIEW.  "Basic Serial Read and Write" is essentially the same thing that you are doing and is tested here and might save you a bit of time.  Anyway, take a look if you have a second. Best of luck with your application!
    John H.
    Applications Engineer
    National Instruments
    http://www.ni.com/support

  • How to write and read Japanese on my Nokia E5

    I am trying to find out how I can write and read Japanese on my Nokia E5.
    I even don't knwo if it's possible...
    Does anyone have the answer???

    Hello ikokitakun,
    I believe you have to load a version of software on your phone that has the Japanese language pack in it because the version of software on the phone only has the languages for the region that you bought the phone in. for example if i bought my phone in NZ it would have English, Malaysian and maybe Philippino. There are "dodgey" places you can go to get the software changed but if you do this you void your warranty so be careful. Nokia doesn't condone the changing of regional software.
    Hope this helps
    -Cheers
    "Freedom is the only way, yeah!"

Maybe you are looking for

  • Resetting a connection matched by ACL

    A requirement is to send a TCP Reset (RST) without changing ASA's global setting "service". The protocol for the connection is unknown. My understanding is that actions such as "reset", "drop" or "drop-connection" is for an "inspect" type Policy-Map

  • ABAP Query (SQ01) Compare bewteen 2 selected fields

    Hello, In ABAP Query has selected fields (say) Fld1 Fld2 Fld3...  I need to output / show only those records where Fld1 not equal to Fld3. Any ideas ?? Both the fields are from the same table in a functional area. Thank You, Deb

  • Configured new language not displayed in user profile Language options

    Hi all, I have a requirement to add new language in portal. In that I have configured the language u201Chindiu201D in portal content translation.Now i want to configure  language options in userprofile. These are the procedures I have followed 1 .On

  • Update from Snow Leopard 10.6.8 to Mavericks?

    I can't install OS X Mavericks, it says something about that it can't be installed on the disk? "disk can not be used to boot up the computer." My MacBook Pro 13" is with an IntelCore i7 and the additional stuff. What should I do?

  • How to download updates for sun creator to install them offline

    I have creator installed machine. I want to update it but it does not have internet connection, so I want to install updates in another machine and install them in this offline machine from where I can download upadates any ideas?