Firmware info for MDS 9509
Requesting latest firmware info for Cisco MDS 9509 switches.
Hello,
The following link will take you to the download section for MDS Firmware:
http://www.cisco.com/kobayashi/sw-center/sw-stornet.shtml
You would need to login using CCO username/password.
Hope this helps.
Regards,
Nikhil
Similar Messages
-
SNMP OID for CPU and Memory Utilization on a MDS 9509
Does anyone know what the OIDs are for CPU and Memory utilization on a MDS 9509?
ThanksCISCO-SYSTEM-EXT-MIB.my is a good place to start and you can determine the OID from the MIB.
Once you feel as though you are on the right track, have a look at:
http://www.oidview.com/mibs/9/CISCO-SYSTEM-EXT-MIB.html
I gather that what you need is:
1.3.6.1.4.1.9.9.305.1.1.1
and
1.3.6.1.4.1.9.9.305.1.1.2
Enjoy.
Stephen -
Where can I find the firmware upgrade for my BB playbook? and where can I find documentation on how to do it?
also, does firmware upgrade include the operating system as well, like in other tablets?
Solved!
Go to Solution.there is no firmware update that I have heard about.
There is an OS update due in February
Click here to Backup the data on your BlackBerry Device! It's important, and FREE!
Click "Accept as Solution" if your problem is solved. To give thanks, click thumbs up
Click to search the Knowledge Base at BTSC and click to Read The Fabulous Manuals
BESAdmin's, please make a signature with your BES environment info.
SIM Free BlackBerry Unlocking FAQ
Follow me on Twitter @knottyrope
Want to thank me? Buy my KnottyRope App here
BES 12 and BES 5.0.4 with Exchange 2010 and SQL 2012 Hyper V -
How to install software on MDS 9509 Switch
Hi,
One of our MDS 9509 switches has died. This used to be supported externally but has now been brought in house. A replacement box is due to arrive soon but I will nee to update the software to the same version that the old box was using and apply the config.
What procedure should I follow to do this? I've downloaded the following kickstart and image files ready to ftp across to the new box.
m9200-ek9-kickstart-mz.3.3.5a.bin m9200-ek9-kickstart-mz.3.3.5a.bin
is it simply a case of running the install all command?
Thanks
DarrenAlso you will need to install license same as on old and restore config. Hope you had config backup somewhere. Additionally you will have to update port security schemes (if configured). Once all done, look for any zone merging errors or conflicts.
Good luck,
Nisar
Sent from Cisco Technical Support iPad App -
My info for battery charging says "Not Charging" when it is charging as per dashboard widget.
My info for battery charging says "Not Charging" when it is charging as per dashboard widget. Since change to lion all slowed down do I need more ram ( have 2 gig). Lost some icons in web site icons and other random icons. So far SL better.
Yeah, it was purchased in August 2008. I'm not really sure what a charge cycle is, but I do plug it in and unplug it a lot to a power source. Mainly because I keep my computer on most of the time (either on or on sleep). So between taking it to classes and stuff, I'll recharge in between and when it's really low, otherwise I run it off the battery most of the time.
On a sidenote, I have went to that information thing about about the battery after letting it sit plug in for a few hours, and now it has this information:
Battery Information:
Model Information:
Serial Number: DP-ASMB016-38ea-4762
Manufacturer: DP
Device name: ASMB016
Pack Lot Code: 0002
PCB Lot Code: 0000
Firmware Version: 0110
Hardware Revision: 0500
Cell Revision: 0200
Charge Information:
Charge remaining (mAh): 61993
Fully charged: No
Charging: No
Full charge capacity (mAh): 61993
Health Information:
Cycle count: 324
Condition: Good
Battery Installed: Yes
Amperage (mA): -1208
Voltage (mV): 12129
System Power Settings:
AC Power:
System Sleep Timer (Minutes): 0
Disk Sleep Timer (Minutes): 10
Display Sleep Timer (Minutes): 60
Automatic Restart On Power Loss: No
Wake On AC Change: No
Wake On Clamshell Open: Yes
Wake On LAN: Yes
Display Sleep Uses Dim: Yes
Battery Power:
System Sleep Timer (Minutes): 10
Disk Sleep Timer (Minutes): 10
Display Sleep Timer (Minutes): 2
Wake On AC Change: No
Wake On Clamshell Open: Yes
Display Sleep Uses Dim: Yes
Reduce Brightness: Yes
Hardware Configuration:
UPS Installed: No
AC Charger Information:
Connected: No
Charging: No
Message was edited by: Akalboy
Oh, forgot to note. Now the time remaining is 10 hours, which is DEFINITELY wrong. -
who can help me with this kernel panic ,i do not look all hard ware have tests done and there is noting in
Unresolved kernel trap(cpu 1): 0x300 - Data access DAR=0x00000000000364FC PC=0x000000000001BA7C
Latest crash info for cpu 1:
Exception state (sv=0x6e101780)
PC=0x0001BA7C; MSR=0x00009030; DAR=0x000364FC; DSISR=0x0A000000; LR=0x0001DF3C; R1=0x6E14FC70; XCP=0x0000000C (0x300 - Data access)
Backtrace:
0x06EFE490 0x0002C30C 0x0002C2FC 0x00031768 0x0003F2A0 0x000B1DD4
Proceeding back via exception chain:
Exception state (sv=0x6e101780)
previously dumped as "Latest" state. skipping...
Exception state (sv=0x62ab1780)
PC=0x00000000; MSR=0x0000D030; DAR=0x00000000; DSISR=0x00000000; LR=0x00000000; R1=0x00000000; XCP=0x00000000 (Unknown)Hi,
Really tough to tell from that little of info, is there more?
Does it boot at all? How often does it KP?
One way to test is to Safe Boot from the HD, (holding Shift key down at bootup), does it KP then?
PS. Safe boot may stay on the gray radian for a long time, let it go, it's trying to repair the Hard Drive
Might try disabling some CPUs.
The cpus boot argument can range from 1 up to the total number of processor cores on your system.
http://developer.apple.com/mac/library/qa/qa2001/qa1141.html
You might try this also, thanks to old comm guy...
This can be done in open firmware,(boot with cmd+option+O+F held down).
setenv boot-args cpus=1
reset-all -
Migrating from Brocade 2800/ 3900 to Cisco MDS 9509
What is the best procedure from migrating from Brocade 2800/3900/12000 to Cisco MDS 9509 especially connected to HP-UX and AIX server.
Without any Downtime I should be able to migrate these servers.
I thought about these options:
1. Use vgexport and vgimport or exportvg and importvg (AIX) after connecting to Cisco MDS. But this requires complete downtime on the application.
2. Take one path down or HBA down and switch the cable and vgextend the devices.
Please let me know if somebody has procedure.
I was successful in HP-UX server using the second options but I cant see all the LUNs. That might be array specific problem also.
If anybody has detailed procedure on migrating this scenario. please let me know.
We are using Persistent FCIDs on our MDS switches.
Thanks in AdvanceAfter connecting 1 cable from server HBA to Cisco S/w, why you are not able to see all LUNs, did you cross-check that...I mean HBA Configuration (max 256 LUNs) or Disk Array library driver to be installed on host side.if that can be sorted out, you can mirror the volumes across the disk arrays.are you using HDS Arrays? I don't know but what is vgextend command you are mentioning...
also did you take a reboot of server or is it online addition on new LUNs...
Also any how if you are not able to see all LUNs that is going to be an issue later as well for migration...pls cross-check that... -
Error: getting dev info for Tape - unrecoverable error
Hi,
I have configured a Oracle Secure Backup version 10.4.0.1.0_LINUX64.
It was working corretly until yesteday that i can't mount the tape because this error appears:
Error: getting dev info for Tape - unrecoverable error
I run this command with obtool:
ob> lsdev -lvg
***0 wst__set_mode: bus 0, target 0, lun 0: IBM,ULTRIUM-HH4,B6W1
***0 wst__get_sn: code=0x0
***0 wst__info: infolen=0xd8, info=0x7fff007bf050
***0 wst__dev_state...
***0 wst__exec: op=0 (nop), buf=0x0, count=1 (0x1), parm=0x0
ioctl_op=0x3, to=300, datalen=0x0, buf=0x0
cdb: 00 00 00 00 00 00 tur
***0 wst__exec: op=2 (sense), buf=0xd1e2ec0, count=96 (0x60), parm=0x0
ioctl_op=0x5, to=30, datalen=0x60, buf=0xd1e2ec0
cdb: 03 00 00 00 60 00 sense, cnt=96
***0 wst__exec: rval=0, status.code/resid/checks=0x0/0x0/0x0
***0 wst__get_sense(int) cmd = 0, sense data:
70 00 03 00 00 00 00 58 00 00 00 00 53 00 36 00
00 00 00 00 00 02 20 20 20 20 20 20 00 20 00 00
00 00 1E 00 00 1C 62 1E 81 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 07 08 18 00 00 00 00 00 00
00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20
ec=0, sk=media err, asc=53, ascq=0
error is: unrecoverable error
flags: (none)
***0 wst__exec: rval=-1, status.code/resid/checks=0x20008111/0x0/0x0
***0 wst__exec: op=7 (readpos), buf=0x7fff007bee60, count=20 (0x14), parm=0x0
ioctl_op=0x5, to=180, datalen=0x14, buf=0xd1e2fc8
cdb: 34 00 00 00 00 00 00 00 00 00 read_pos
***0 wst__exec: op=2 (sense), buf=0xd1e2ec0, count=96 (0x60), parm=0x0
ioctl_op=0x5, to=30, datalen=0x60, buf=0xd1e2ec0
cdb: 03 00 00 00 60 00 sense, cnt=96
***0 wst__exec: rval=0, status.code/resid/checks=0x0/0x0/0x0
***0 wst__get_sense(int) cmd = 34, sense data:
70 00 03 00 00 00 00 58 00 00 00 00 53 00 36 00
00 00 00 00 00 02 20 20 20 20 20 20 00 20 00 00
00 00 1E 00 00 1C 62 1E 81 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 07 08 18 00 00 00 00 00 00
00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20
ec=0, sk=media err, asc=53, ascq=0
error is: unrecoverable error
flags: (none)
***0 wst__exec: rval=-1, status.code/resid/checks=0x20008111/0x0/0x0
***0 wst__dev_state: code=0x20008111
***0 wst__info: code=0x20008111
Error: getting dev info for Tape1 - unrecoverable error
***0 wst__conn_type returning 1 (code 0x0)
***0 wst__close: wh=0x0
Tape1:
Device type: tape
Model: [none]
Serial number: 1068037161
In service: yes
Automount: yes
Error rate: 8
Query frequency: [undetermined]
Debug mode: yes
Blocking factor: (default)
Max blocking factor: (default)
UUID: c60554ca-0562-1030-8cdb-d4ae528eb115
Attachment 1:
Host: bosmgmt.bos.local
Raw device: /dev/sg3
Connection type: SCSI
Inquiry data:
Vendor: IBM
Product: ULTRIUM-HH4
Firmware: B6W1
Serial number: 1068037161
Hardware compression: not available
Hardware encryption: not available
Thanks in advanceIt's reporting a hardware media error on the drive. Basically you've got a hardware fault.
Thanks
Rich -
Cisco MDS 9509 and HP Blade server problem
I have a big problem , when i connected to MDS 9509 to HP VC-FC 8GB the module in MDS 9509 did not detect the HP module . I think this will be because MDS 9509 uses VSAN technology , but HP blade is not support this feature. Please help me
I am fairly certain that the HP blade chassis has HP branded Brocade FC switches. These switches need to be placed into AG mode and rebooted. On the Cisco MDS core the NPIV feature must be enabled.
Here is more info on the Brocade AG mode -
http://www.brocade.com/solutions-technology/technology/platforms/fabric-os/access_gateway.page
http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/AccessGateway_DS_02.pdf
Cisco NPIV info
http://www.cisco.com/en/US/prod/collateral/ps4159/ps6409/ps5989/ps9898/white_paper_c11-459263.html -
MDS 9509 - Mgmt Interface alerts
I am seeing the following entries in the logs for my MDS 9509 :
2007 Feb 7 01:48:03 PORT 5 IF_UP Interface mgmt0 on slot 5 is up
There are no other entries in the log that the mgmt0 interface went down so why would alerts say that it is "up" ?Looks like the mgmt interface has been bouncing up & down since Sept. What is this attached to? What does that log say? Is the duplex and speed the same on both sides? Can you replace the cable? Does the show interface mgmt 0 show increasing CRC and/or output errors? These are the things to look for. Try a new cable as it's the easiest and most probable issue.
-
ISL Ports (E ports) on MDS 9509 are showing Gracefully Shutdown
We have an ISL connection between E mode ports of two MDS 9509 Switches . (FabricA)
Upon Health Check I found that these ISL ports on both the switches are down and when I checked syslogs on both switches they show "Interface X/X Gracefully shutdown"
I checked the Cisco document for this error which says -
"The Cisco NX-OS software implicitly performs a graceful shutdown in response to either of the following actions for interfaces operating in the E port mode:
If you shut down an interface.
If a Cisco NX-OS software application executes a port shutdown as part of its function."
So no one has shut down these ports manually and I am not sure what the second point (If a Cisco NX-OS software application executes a port shutdown as part of its function) means
I tried shut / no shut on these ports bt no go.
I need to know what could be the problem and its resolution.Hi Vishwa,
Sounds like there is a problem between switches. Look at a "show interface" and see if it is "error disabled". I don't know the topology, maybe optical equipment or patch panel between switches? You can look at the signal levels on the interfaces with "show interface fcx/x after the no shut. The signal levels are not valid if the interface is not "in sync" but you can still get an idea of no receive signal. Do a "not shut" on both sides and look at the levels. Look for other messages in the logs at the same time and post those here.
Best regards,
Jim -
Firmware Update for WAG200G to fix Security Hole
Hello,
I use a Linksys WAG200G with firmware version 1.01.09, and recently became aware that this particular model has a publicly known exploitable backdoor (See: http://www.businessinsider.com/cisco-warns-about-security-hole-2014-1 for more info).
Has this security hole been fixed? If yes, where can I download an update for it?
Thanks for your time,
SamThanks for the advice to contact HP tech support!
I have tried in multiple ways since November 2009 to contact HP, when I got the first (of 4) printers. The first 3 printers was subsequently replaced.
Finally in late June 2010 I got the message that there was coming an firmware update for Windows, but not for Mac's. The firmware should improve among other things the paper pick up (load paper issue) and the print-heads life.
I have applied the Windows firmware on the printer from a pc, but still seems to have load-paper issues, even using HP Bright White paper, when printing from Mac's. I have not tested the printing from a pc, but assumes that a firmware upgrade the printer, and are not specific to a certain OS. -
How to know firmware version for all devices in a CUCM cluster
Hello,
We need to know the firmware version used for each one of the devices in a CUCM cluster (version 6.1)
Anybody know if we can get this info for example wit the BAT?
Thanks and regards,You typically need to use a 3rd Party application to do this.
There are many that can do basic device information gathering, but if you are looking for a complete endpoint solution that scales to 10,000+ devices you should have a look at PhoneView from UnifiedFX (http://www.unifiedfx.com)
Thanks
Stephen -
Get user public key (ssh) from MDS 9509
how can get public key from a user on MDS 9509?
I'm not sure exactly what you are looking for, but to create keys for SSH, you will want to enable SSH like this:
ssh server enable
Then, you can generate a key like this:
ssh key
Or to specify the key for a user, it would be like this from the CLI:
username ssh -
MDS 9509 Stencils and Sample Diagrams
Hi,
Need some stencils and possibly existng sample-type diagrams for a medium sized deployment of two MDS 9509 core switches. Two seperate Fabrics for redundancy in the diagrams would help too.Please download the VISIO stencils for the MDS products from the link below:
http://www.cisco.com/en/US/prod/assets/visio/product_visio_icon0900aecd800d1dc0.zip
Maybe you are looking for
-
Problem While Saving the editable ALV GRID
Dear Experts, I have a scenario in which i am display the ALV(using class) with some data in the custom container of module pool screen in the non-editable mode.Also i have save and edit buttons.If i click the edit button i have written the code to e
-
Sytem should not allow to save the sales order based on risk category
Hi, My user want to control the creation of sales orders based on risk category in credit control area. We created a new risk category - 30 Not authorized. And we made necessary configs also , like assignment of risk category and company code in OVFL
-
I understand this can be done in some previous generations, and am just not sure whether it works in my situation. I have a MacBook Pro (2009) and a brand new iMac 27" (2011). It seems that MBP has a mini displayport and iMac has 2 thunderbolt ports.
-
How can change language of application dynamic?
In the dialog I have combo box in which I can select desire language for application. When I select value I save this value in the config file. But language change ONLY when I exit and again enter to the application. How can change language of applic
-
We need to change a component quantity in the BOM. BOMs are not ECN number maintained. The Material No. stays the same. How can we change the BOM and still track the previous orders which needed that BOM?