Follow Up action for UD

Hi,
My client uses inspection type 89 for creating inspection lot. They have HU/SU management active in warehouse. When inspection lot is created for production batch, material stock and HU's are shown in quality inspection. When UD 1000 (Accept) is made, they have a follow up action FM linked to it which posts the HU's to unrestricted stock using VLMOVE 321 movement. The process works correctly through QA11. But when I do UD using BAPI BAPI_INSPLOT_SETUSAGEDECISION in custom program, the follow up action is not triggered. The stock remains in QI. Do I need to call the follow up FM also in program? Why does BAPI not trigger follow up action?
Thanks,

Please see OSS note 1865492.

Similar Messages

  • Send mail from follow up actions for tasks in service notifications!

    Dear All,
    I want to send mail to the user from a follow up action in the task assigned to a service notification.
    In customizing which function module I should select for follow up actions for tasks?
    Thanks and Regards,
    Satyajit P

    Hi,
    You can use function module QM06_FM_TASK_SEND_PAPER or QM06_FM_TASK_SEND_PAPER_ATTACH.The document is sent only after the associated notification is saved.You need to enter the function module "QM06_SEND_REPLY_STEP2" in Customizing of the action box as "FM when saving".

  • Follow-up action for partial lots

    Guru's - Need your valuable input in the scenario below
    The requirement is to send an email for the partial lots based on the valuation or UD code from the selected sets using follow-up action.
    I know as per standard SAP we can send an email based on the UD code at the inspection lot level using function module QFOA_UD_LONGTEXT_SENDING
    Please suggest me the function module or available options that i can use for sending an email at the partial lot level.
    Thanks,

    Appreciate your Quick response.  I dont see any standard function module(FM) that can be used for partial lots.  I did try to assign the standard FM for insp. lot to the partial lot & its giving me a dump error(Parameter Missing).
    We did create a custom module to send an email for multiple users based on the UD at the Insp. lot level but i dont see any standard FM available that i can use for partial lots. Please Help.
    Thanks,

  • Follow up action 14 Inspection Type- Equipment status change

    could anyone tell me which follow up action for 14 inspection type is to be bought into for changing Equipment Availablity status to Non Availability status when I reject calibration lot for that particular equipment.

    hi
    kindly check whether this FM will work for you QFOA_OBJECT_STATUS_SET
    regards
    thyagarajan

  • Quality Notification: Create Task as Follow-Up Action

    Hi QMu2019ers
    I have a requirement from my business, to create tasks as a follow up actions from completed tasks. Let me explain the process.
    We have a catalog with 4 codes e.g. ZTS1 u2013 0001 to ZTS1 u2013 0004
    When the user assigns ZTS1 u2013 0001 to a task in the notification and that task is set to complete, we want the system to automatically create the next task in the catalog, i.e. ZTS1 u2013 0002, when that task is complete the next task from the catalog is added and so on.
    I have looked into follow-up actions for tasks, but there does not seem to be a standard option for this.
    Does anyone know how I can implement such a solution?
    Many thanks for any advice given.
    Neil

    follow-up actions of  tasks is triger when the tasks are assigned into the notification, not when the task are completed.
    Try user-exit QQMA0014, you can assign additional tasks before notification is saved.

  • Follow up control action for Training and Event Management

    Dear Expert,
    I am new to TEM module. After the training course, I would like to set the course result to each participant (pass or fail)
    I tried to set the "Follow-up control options" for the selected course type and then execute tcode pv15, but still cannot trigger the follow up action.
    Can anyone help me on this?
    Million thanks,
    WF

    Hi Wiliam,
    For this purpose, implement BADI HRBAS00INFTY - IN_UPDATE method.
    IF sy-tcode = 'PV15' OR ( sy-tcode = 'PSV2' AND sy-xcode = 'EVFO' ).
    LOOP AT PLOG_TAB ...
    POP-UP ....
    ENDLOOP.
    ENDIF.
    Regards,
    Dilek

  • Implementing 2 Badis for adding new internal follow-up actions and saving

    Hi Guys
    I would like assistance with the implementations of two badis in EMW.  The one badi is called /SCWM/IF_EX_QFU and is used for adding new internal follow-up actions and the second badi is called /SCWM/EX_QFU_SAVE and is used for saving the new follow-up actions that that have been created.
    Regards
    Maud

    Hi Guys
    I would like assistance with the implementations of two badis in EMW.  The one badi is called /SCWM/IF_EX_QFU and is used for adding new internal follow-up actions and the second badi is called /SCWM/EX_QFU_SAVE and is used for saving the new follow-up actions that that have been created.
    Regards
    Maud

  • Follow-up action : please help - Inspection Lot related

    Hi,
    I am having the following trouble:
    Through MB02, a printout is generated to the local printer (LOCL).
    However, through QA11, when we save, we have a custom follow-up action attached that pops-up a
    dialog screen.
    The follow up action is triggered when a usage decision is changed for the inspection lot.
    The follow-up action (configured in IMG) calls a Function Module and a screen, which in turn populates
    a value into a custom DB table (based on the buttons, on the screen, sending either to LOCL or to a
    zebra printer).
    Now, what has to happen is that after inserting the value into a custom table, it should also open a sapscript and output.
    The Sapscript and print program are there, with the print program being created 3-4 years ago by someone
    else. However, even though we have code in the print program to update nast, in turn creating a message
    for output (1st the custom DB table is checked to see if the values match, MATNRCHARG), It does not update
    NAST. When we go through MB02, it does, but this should happen automatically after selecting one of the radio
    buttons on the original pop-up & selecting print.
    Please help. I don't know what to do and can't enable a debugger from the pop-up and if going though QA11,
    I can't get it to stop inside the print program (only inside the custom FM).
    Cheers,
    John

    hi
    kindly check whether this FM will work for you QFOA_OBJECT_STATUS_SET
    regards
    thyagarajan

  • Upgrade to 4.0 - asking for 'follow-up activities for middleware'?!??!!

    HI,
    My upgrade from 3.1 to 4.0 has been going smoothly up to now.
    It stopped in phase REQ_BBWPCRM now asking me to perform the actions in the chapter 'Follow-up activities for the Middleware' in the documentation 'Upgrade Guide - CRM 5.0'.
    No mention of this is made in the Solution Manager 4.0 upgrade guide. I had a look at the CRM upgrade guide and those steps have nothing to do at all with Solution Manager and seem very CRM specific.
    Anyone has any advice on what to do at this point?
    I am tempted to just ignore this and to say Continue in the Upgrade Assistant, but I dont want to miss something important and then have to restore.

    See:
    * http://kb.mozillazine.org/Software_Update (Software Update not working properly)
    Remove the files in the updates and updates\0 folder.
    You may need to delete active-update.xml and updates.xml as well if present.
    You can probably find the updates folder in the Firefox program folder.

  • Follow up action in QM

    Hi All,
    Could any let me know what is the use and process of followup action in QM during notification.
    Regards,
    Satyajit

    It is applicable for the tasks that you perform in QM notification.
    In QS 42
    code group catalog = 2
    code group = *
    in side select any code froup and then click on codes
    for each code you can give follow up action, if this code is sellected in QM notification then system will trigger the follow up action assigned,
    Std follow up cation given by SAP are
    ABGLEICH     Comparison: R/3 notif. w/ SAP
    AWE     Change request
    CLAIM     Create claim
    CLMMAIL     Mail from claim
    CLMSIMUL     Create simulation version
    DELIVERY     Create outbound delivery
    EXAMPL_1     Example (dummy function module)
    G_MOVE     Enter goods movements
    REP_ORD     Create repair order/dep. follow-up func.
    REP_VE     Record decision in repair order
    SR_ECR     Create EngChangeReq./dep.follow-up func.
    SR_ECR2     Create EngChangeReq./dep.follow-up func.
    SR_PCRFL     Document flow for PCR
    UD     Record usage decision
    VL02     Change outbound delivery

  • Follow up action in UD

    Dear all,
    I have assigned mail3 follow up action to UD selected set for rejected lots.system is sending mail to user only .my user needs a list of recipents to be added to follow up action.(by default).What are the settings to do.
    thx&regds
    prasad

    Hi,
    Copy the function module in customizing under Quality Inspection -> Follow up action and modify the standard functional module as per your requirement by the help of ABAPer and assign the same functional module to same IMG.
    Regards,
    Babu.S

  • SAP QM Issues regarding follow-up action after Usage Decision

    Dear Gurus -
    Kindly need your expertise to resolve these issues regarding follow-up action.
    1. After taking the UD i need to trigger the follow-up action to send an email with the long text to a group of people. As per standard SAP the email goes to the person taking the UD. Kindly can some one explain what & where do i need to make the changes. Also please let me know what is the customized Email ID table where mail ID's will be stored which fuction module can extract.
    2. Can i also use the same functionality for partial lots during inprocess inspection. I need to send an email to a group in case the valuation is rejected for that operation.
    Any response is highly appreciated.
    Thank You.
    Edited by: sunil t on Jan 6, 2010 7:03 PM

    Hi
    Please go through my recent thread
    Incomming Inspection Auto mail if Rejected
    Regards
    Sujit

  • Triggering of Notification from Follow Up action

    hi
    SDN,
    in calibration order. if i reject inspection lot ,system should trigger notification as follow up action.
    Can any one suggest the name of functional module that can be assigned in follow up (QM customizing)action so that system trigger notification as inspection lot get rejected.
    All other follow uop actions like.. order teco, equipment status change, etc. i have done and tested.
    Regards,
    amit

    hi,
    Thanx for promp reply. i have tried to assign these functional module in followup actions but system throwing en error . it's given below -
    Function module QFDL_INIT_NOTIFICATION does not have E_SUBRC parameter
    Message no. QM403
    Diagnosis
    The interface of the function module you entered is not compatible with the interface of the sample function module.
    Procedure
    Check the function module and add the missing parameters to the interface.
    suggest how to proceed.
    regards,
    Amit kushwaha

  • Create  notification as follow up action

    Hi,
    Can anybody explain to me which functionmodule (follow up action) to use for creating a PM notification from an inspection lot UD.
    Thanks in advance
    Peter

    Hello Nehal,
    thanksfor your reply.
    I have linked the inspection type to a PM notification type and i want the Notification to be created on the Equipment.
    I can already create if manually, from the inspection lot, but i want to do this automatically. In the selected set for the Usage decission, you can define follow up actions, but when checking the follow up actions I'm not sure which function module to use.
    So which function module should i use? or are you saying that there is no standard function module and  that i should write the function module from scratch?
    There is no way to create a PM notification from the inspection lot with standard SAP?
    If somebody knows, please let me know. Thanks
    Peter

  • Action date field in follow up action

    If you specify a follow-up action in a contract, you must enter a date or a date rule in the Action date field.
    question where is the Action date field i search for it in sales document contract and i don't found in contract data
    please help me

    HI
    i don't think so, there is such type of option while doing UD. actually when yo perform UD system makes completiond date automatically from Programbased.
    -ashok

Maybe you are looking for

  • IPhone and iPad connected but not with iCloud??

    When I updated to iOS 6.1, I was asked if I wanted to connect all devices. My mistake was selecting yes! I have an iPhone and iPad I just got for Christmas; I was using the same email on both devices for iMessages but I hate receiving all messages on

  • How do I get SP2 for Windows XP Pro 32-bit?

    I have Windows XP Pro 32-Bit... But as far as I know it does not have Service Pack 2 (SP2)... The Boot Camp instructions say you need at least SP2 to install boot camp and you can't install XP and then update to SP2... Is there a way around this?

  • Finding Events in debug mode?

    Dear All, I found a list of events which will be used for the transaction EA10 by the method mentioned in the video. http://www.sap-isu.net/video/fica-events. Out of the many events which are triggerred one of them is R431. Right now the function mod

  • [svn:cairngorm3:] 14658: Migration to Parsley 2.2 and Flex SDK 3.5.

    Revision: 14658 Revision: 14658 Author:   [email protected] Date:     2010-03-10 02:08:29 -0800 (Wed, 10 Mar 2010) Log Message: Migration to Parsley 2.2 and Flex SDK 3.5. Removed Command implementation of Integration library in favor of Asynchronous

  • SQl server to Oracle -- Replicat error command disallowed by current ..

    I am trying to set replication b/w sql serve *& oracle.. Source -- SQL server 2005 SP4. Target - Oracle 11.2.0.3 - using ASM ..single instance.. The error log is .... 2012-02-10 17:33:47 ERROR OGG-00664 Oracle GoldenGate Delivery for Oracle, rcatd1.p