Force exponential window in sound&vibration toolkit

hello,
I work on shock acquisition and analysis. I would like to use a window "force exponential" before computing fft. But I don't find the vi to do it directly in sound&vibration toolkit and VI express toolkit.
 So I try to do it by using the VI in signal processing toolkit (see the link picture please) but I lost the time data information (the VI uses array data and not dynamic data with time). how to recover the time data?
J F
Attachments:
exponential_window.jpg ‏131 KB
fft.jpg ‏171 KB

Bonjour,
Je ne suis pas sur d'avoir bien compris, vous désirez avoir le temps écoulé ? le temps où la mesure a été faite ? Pouvez vous me donnez plus de précisions svp. Ci-joins un vi en 8.5 qui pourra peut-être vous inspirer.
Cordialement,
Steve M.
National Instruments France
#adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
>> Vidéo-t'chats de l'été : présentations techniques et ingénieurs pour répondre à vos questions
Attachments:
exp2.vi ‏84 KB

Similar Messages

  • The difference of sinad.vi between Sound & Vibration Toolkit and Singal Processing Toolkit

    Hi, I'm confused with the the difference of sinad.vi between Sound & Vibration Toolkit and Singal Processing Toolkit.
    When the input waveform is single tone, the output is almost the same, but raises much discrepancy while a certain distribution of the spectrum. Does the sinad.vi have some limitation to the input signal? Did I miss some setting of the terminals? Hope someone can give me some suggestion.
    Attachments:
    SINAD(Front).png ‏85 KB
    SINAD(Block).png ‏77 KB

    Hi, here's the subVI for the test! Hope someone can give me some suggestion.
    Attachments:
    SINAD.vi ‏96 KB

  • Reading of Velocity and Displaceme​nt is incorrect while accelarati​on is correct (Sound Vibration toolkit)

    Hi,
    I'm trying to read vibration using the following system:
    Sensor: Accelaration sensor
    Device: NI Hi-speed USB carrier NI USB 9162, NI 9233 4 ch 24 bit IEPE analog input.
    Software: LabVIEW, NI Sound and Vibration Toolkit, DAQ assistant
    The VI that I've for reading accelaration, velocity and displacement is attached. It is giving correct output for accelaration but incorrect result for velocity and accelaration.
    The problem seems to be in the use of intergration VI supplied with Sound/Vib toolkit.
    I'm also unable to drag drop cursor in the graph of the attached VI.
    Can anyone help me getting the correct readings and use the graph?
    thanks in advance,
    Aniket
    Attachments:
    vibration.vi ‏223 KB
    vibration.jpg ‏74 KB

    Hi,
    Have a look at the following VI. This seems to solve the problem.
    Regards,
    Vaibhav
    .......^___________________^
    ....../ '---_BOT ____________ ]
    ...../_==O;;;;;;;;_______.:/
    Attachments:
    vibration.vi ‏140 KB

  • How to acquire sound from microphone using Sound & Vibration toolkit

    Hello All,
    I need to know how we can acquire signals from microphone using S&V toolkit.

    Hi pmg,
    If you have the Sound and Vibration Measurement Suite installed, you may want to take a look at the examples here:
    <LabVIEW Directory>\examples\Sound and Vibration\Audio Measurements
    Thanks as kudos only

  • Sound Vibration ToolKit IEPE

    my client had a program written in LV 7.1.1 / S&V Toolkit 3.1 that works, but needing to add features, upgraded to LV 8.6.1 / S&V Assistant 7.0; and now the data is off. I have looked at the data from the accelerometer in MAX and with IEPE enabled I get the expected data and without IEPE enabled I get what the upgraded program returns. So I know what the problem is ...
    On the block diagram I am using to enable IEPE excitation "DSA Device Detected: PCI-4461 [svx_DAQmx Popup for DSA.vi]" - but it isn't working, or I am doing something wrong, or need something additional.
    Ideally we would like to not have this interactive, but it looks like making Interactive FALSE ignore all the input values (which doesn't make much sense) and trying it in interactive mode = TRUE and entering the info into the controls didn't seem to work either.
      Anyone point me in the right direction?
    thanx
    lmd2
    Lawrence M. David Jr.
    Certified LabVIEW Architect
    cell: 516.819.9711
    http://www.aleconsultants.com
    [email protected]
    Solved!
    Go to Solution.

    Good Afternoon Lawrence,
    You mentioned the S&V Toolkit and the Assistant.  Is your new
    program written in LabVIEW or did you use the S&V Assistant?  Have you seen this KnowledgeBase article?
    How Do I Enable IEPE Excitation on My DSA Device in DAQmx?
         http://digital.ni.com/public.nsf/3efedde4322fef198​62567740067f3cc/3ad6cce935192b4086256f6b0079cb1f?O​...
    Regards,
    Charlie Piazza
    Staff Product Support Engineer, RF
    National Instruments

  • Sound and Vibration Toolkit

    We have LabView 7.1 and the latest Sound and Vibration Toolkit. I am interested in finding the natural frequency of metalic parts AND entire mechanical assemblies. To obtain the natural frequency, we have purchased an accelerometer and impulse hammer to perform bump testing. From the reading I've done, I believe I should use the FRF functions from the S&V toolkit. Can someone confirm this or direct me to the proper method?
    thanks for your help

    Hi WantToGolf,
    Sounds like you're on your way!
    Cable the output of the impulse hammer to analog input 0 and the output of the accelerometer connected to your device under test (DUT) to analog input 1. The frequency response functions (FRFs) included with the Sound and Vibration Toolkit are the methods you'll use to find the natural frequency of the DUT.
    I would recommend using Baseband Frequency Response (DAQmx - No excitation).vi, located at:
    C:\Program Files\National Instruments\LabVIEW 7.1\examples\Sound and Vibration\Frequency Analysis\Dual Channel Analysis\SVXMPL_Baseband FRF (DAQmx - no excitation).vi
    This VI continuously acquires data from two channels in the same device. No source is provided from the DAQ board, as you will be providing one from the impulse hammer. Triggering from either channel is supported.
    The data from each channel is scaled to engineering units, windowed, and the frequency response is computed. The results of the frequency response measurement can be displayed on a Bode plot or a Nyquist plot. The coherence is also graphed to evaluate the validity of the measured frequency response.
    You could then use the frequency response to determine the natural frequency of the DUT. Let me know if you have further questions or if this does not resolve your issue!
    Chad AE
    Applications Engineer

  • Need help finding Sound and Vibration Toolkit Example Files

    I need help finding some Sound and Vibration Toolkit Example Files?
    http://www.ni.com/white-paper/3779/en
    From this link you get:  getting_started_otb.llb
    The missing files are:
    OAT Truncate Time Indices.vi
    Speed profile.ctl
    oa_Config Time or RPM Segment.vi
    svl-Complex Datatype Default.vi
    Running Windows 7, LabVIEW 2011, 32bit
    Sound and Vibration Measurement Suite
    Sound and Vibration Toolkit
    Thanks,
    -SS
    Solved!
    Go to Solution.
    Attachments:
    License S and V.png ‏4 KB

    SS,
    You can find these files here:
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Resample Order Tracking\SubVIs
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Tach Process\SubVIs
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Resample Order Tracking\SubVIs
    svl-Complex Datatype Default.vi changes to svc-Complex Datatype Default.vi
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\_NISVFA\_Shared subVIs\Common
    Make sure you are license activated, and you will have to dig through the *vi and relink a subvi.
    Then you should get a white arrow.
    -SS 

  • SOS(The Question of SVXMPL_Settled Dynamic Range (DAQmx) example in Sound and Vibration Toolkit)

    The SVXMPL_Settled Dynamic Range (DAQmx) example in Sound and Vibration Toolkit only run one time.
    How do it ? I want to run again and again.
    Sorry, my English very poor.
    Windows XP P
    LabVIEW 7.1 P
    Sound and Vibration Toolkit 3.1
    帖子被jwdz在10-22-2005 11:00 PM时编辑过了
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview

    Hi:
    I have simulated PXI-4461 in MAX,but the SVXMPL_Settled Dynamic Range (DAQmx) example in Sound and Vibration Toolkit  can not right run.
    Windows XP P
    LabVIEW 7.1 P
    DAQmx  7.5
    Sound and Vibration Toolkit 3.1
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview

  • Problem in Sound and Vibration toolkit Installation

    I have Sound and Vibration 3.1 installed in my machine and did upgrade (without unistall SV 3.1) to SV 4. VIs doing in other machine with SV 4 don't run in my machine. I try uninstall version 3.1 and stay only version 4, don't solve problem. The SV version 4 don't appear in function windows, but is installed in windows XP. Sound and Vibration section in the function windows only appear if i install version 3.
    How do upgrade of version 3.1 to version 4 and do the version 4 section appear in the window function?
    Leonardo de S. Cavadas
    Maintenance Engineer and Inspection - Bureau Veritas do Brasil
    Engineer Metallurgist with emphasis in Advanced Materials
    Technologist in Computer Science

    Solution for WinXP:
    1 - Enter in Configuration - Control Panel - Add/Remove Program;
    2 - Select National Instruments Software, click in Change;
    3 - In the new windows that opened, remove the Sound and Vibration toolkit 3.1 version and 4.0 version;
    4 - Restart Computer
    5 - Reinstall Sound and Vibration Toolkit 4 version.
    It's Work.
    Leonardo de S. Cavadas
    Maintenance Engineer and Inspection - Bureau Veritas do Brasil
    Engineer Metallurgist with emphasis in Advanced Materials
    Technologist in Computer Science

  • How to install sound and vibration toolkit 8.5

    Hello all, I have just started using labview and would like to run the "SVXMPL_Third Octave Analysis for Multiprocesor" example as an example for multithread programming, but I run into the issue that the "Sound and Vibration" toolkit is required before running the example.  I have installed the labview 8.5. I have gone through the posed link and gone through  the list of products installed in my machine (ControlPanel>Add and Remove Programs> National Instruments Software), but I couldn't find the "sound and vibration toolkit". I have tried to run the installation setup in order to add the toolkit. it looks like I have already installed all the available software. I don't know how I should install the toolkit.  I appreciate on any comments on how to install the toolkit.   I appreciate if you can help me on how to install "sound and vibration toolkit" in my machine.  

    Never mind.  I got it.

  • Third octave operations with "sound and vibration toolkit"

    Hi!
    I’m working about third octave decomposition with a vibration signal.
    I’m using the sound and vibration toolkit.
    The sample frequency of my signal is 2400 Hz.
    And I’m working with a 1 second vibration signal (so 2400 points).
    Fs = 2400
    N = 2400
    I need to understand the different and successive operations that the “SVT Fractional-octave Analysis [IEC].vi”VI do.
    In fact, I think that my frequency resolution (df = Fe/N=1Hz) is too low.
    Do you have a solution?
    Maybe I could turn into my 1 sec signal in 10 sec signal with 10 recopies and assemblage of my previous signal?
    N’ = 10N so df = Fe/10N = 0.1Hz.
    Thanks for your help.
    Bastien of paris

    Hello,
    The first thing you have to do is to read the Chapter 7 of the user manual of the Sound and Vibration Toolset.
    You can find it in : program -> National Instruments -> LabVIEW Sound and Vibration Toolset -> User Manual
    This chapter discusses fractional-octave analysis, including fractional-octave analysis theory, averaging modes supported by the
    Octave Analysis VIs, settling time, and ANSI and IEC standards.
    regards,
    Marc L.
    NIF

  • Sound and vibration toolkit - Comment enlever l'offset des signaux délivrés par l'accéléromètre

    Bonjour,
    J'ai en ma possession le toolkit sound & vibration ainsi qu'un accéléromètre ICP couplé à un conditionneur de signal et une carte d'acquisition NI 4431.
    J'ai désactivé le courant d'excitation de la carte en paramétrant "Iex Source" en "external" et en mettant 0mA pour valeur à "ex Value". Je pense qu'ainsi, c'est bien mon conditionneur de signal qui prend en charge l'excitation de l'accéléromètre ICP (pouvez-vous me le confirmer au passage?).
    Lorsque je lance mon programme j'obtiens bien le signal des 3 axes de mon accéléromètre, mais ceux-ci ont un offset d'environ 140 g. Pourquoi? J'ai cherché dans les options si il y avait moyen d'agir sur cet offset mais je n'ai rein trouvé. Savez-vous si cet offset est normal ou s'il n'a aucune raison dexister?
    Par avance merci.
    Teka
    Labview 8.2 version étudiante
    Sound & Vibration Toolkit

    Bonjour Teka,
    Votre accéléromètre travail éventuellement autour d'un point de fonctionnement (offset). Si tel est le cas, vous pouvez filtrer la composante continue de manière logicielle ou matériel avec un filtre.
    Cordialement,
    Rémi D.
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    >> Les rencontres techniques de NI - Mesures et acquisition de données : de la théorie à la mise en ...

  • Sound and vibration toolkit using Keithley Card

    Hello everyone,
    Might be doing a project soon using the LABVIEW Sound and Vibration Toolkit(1/n octave vibration analysis required) with LABVIEW 6.1(Sorry, try convince my Boss to upgrade). We have a Keithley KPCI-3101 card avaliable to us for the analog input.
    Do any of you forsee a problem using a non-NI card with the sound and vibration toolkit? I can find very little on the internet discussing using non-NI cards with the toolkit.
    This might sound like a stupid question but I need to be
    100% sure that there are no problems.
    Thank you for any help you can offer :-)
    Cheers
    Jurgen

    Hello Jurgen,
    Of course the integration with National Instruments boards (PCI-4472 or 445x boards) is best suited with the Sound and Vibration Toolkit. However it is possible to use the toolkit without National Instruments hardware. Most of the examples that ship with the toolkit use NI-DAQ data acquisition calls. You need to remove them from the examples and substitute them for the driver vi's that your board uses. There are also a couple of examples that use simulated signals (so there is no hardware at all involved).
    One thing to be aware of is the sample rate. Recommended sample rates, that are used in most examples are 51.2 kS/s. You may need to check if your board is capable of doing this.
    Also all the functions use the waveform datatype, (which include
    s timing information), so you need to convert your array of data to this datatype, using the build waveform function.
    Hope this answers your question.
    Best regards,
    Erik vH.
    Applications Engineering
    National Instruments

  • Sound and Vibration Toolkit License

    Hi.. I have LabView 2009 SP1 installed in my PC. Currently I am running in evaluation mode, but planning to buy a run - time license. I also have the Sound and Vibration Toolkit on evaluation mode. Do I need to buy a license for this toolkit too? what if I buy the debug/deployment license for labview?

     Hi JR Tager, as Dennis mentions you need to buy the license for each of your development computer. In this case the best option is to buy the Developer Suit with Sound and Vibration Option this way you get a discount in the module. Also the toolkit and the Module have to be the Same version than your LabVIEW for example if you are using LabVIEW 2010 you need the 2010 Sound and Vibration Toolkit.
     Not all toolkits and modules, requires a Runtime but in this case the Sound and Vibration Module does. Which mean for every executable you create you will need to buy a RunTime License.The part number for the NI Sound and Vibration Software Run-Time License is 779875-01.
    Which Software Requires a Run-Time License?
    Best Regards
    Benjamin C
    Senior Systems Engineer // CLA // CLED // CTD

  • Sound and Vibration Toolkit with NI-SCOPE AND NI-FGEN

    Hi,
    I would like to use the Sound and Vibration Toolkit with the NI-FGEN and NI-SCOPE,specifically the stepped sine analysis. The stepped sine VI's are compatible with only DAQmx and not NI-SCOPE and NI-FGEN,right?
    Any way around this?

    Hi there,
    Firstly I assume you mean Swept sine and not stepped!?
    This is the closest thing I could find:
    http://zone.ni.com/devzone/cda/epd/p/id/3347
    I had a look for you and there is nothing that works with a swept sine in FGEN or SCOPE natively that we supply.  However I do believe that a lot of the functionality could be programmed in FGEN and SCOPE vi's.
    You would however need to make copies of all the Swept Sine VI's and replace all DAQmx calls and property nodes with the appropriate SCOPE/FGEN vi's.
    Not a short answer I'm afraid and I can't guarantee that all the functionality is going to be there.
    Sorry its not a better answer.
    AdamB
    Applications Engineering Team Leader | National Instruments | UK & Ireland

Maybe you are looking for

  • ITunes will not open after update to 11.4

    I updated iTunes, along with the other updates I was prompted to install but now my iTunes will not open. At all. No error message or anything. Please someone help? Thanks.

  • Progress Tracker

    Hi Experts, I have a form with lot of fields spanning across multiple pages - in order to make the form user friendly and enable the user to keep track of their form filling activity, I want to add a progress tracker which will track the percentage o

  • How to see AppStore & get apps for iPad in English from overseas?

    The Facts (ma'am): I just received a new iPad as a gift. It was purchased in Russia, where I am going to be located for some time. My Apple account is in USA, where I am from and where I bank. I created it when I was there in 2009 and bought a MacBoo

  • VerifyError: Error #1053: Illegal override of z in mx.core.UIComponent in adobe flex  pease help me!

    While I tried to run already existing adobe AIR application in Flex Builder3 using  Flex SDK4. I got this error VerifyError: Error #1053: Illegal override of z in mx.core.UIComponent in adobe flex please anyone help me to solve it

  • IMac is stuck updating to Mac OS 10.9.1!

    I have a mid 2007 24" iMac and i was updating to Mac OS 10.9.1 but when I got to the rebooting part, the bar is stuck at the beginning. I don't know if I should reboot or not. PLEASE HELP!