Forms 6 can't connect to PO 8.1.5 on Win2000

I recently installed Form 6 and PO 8.1.5 on windows 2000. Following advice in this discussion I installed Forms 6 first to DEFAULT_HOME and PO to ORACLE8_HOME. I copied the tnsnames.ora from ORACLE8_HOME to DEFAULT_HOME but I still cannot connect from SQL*Plus from DEFAULT_HOME.
The entry in my tnsnames.ora is as follows:
ORACLE8 =
(DESCRIPTION =
(ADDRESS_LIST =
(ADDRESS = (PROTOCOL = TCP)(HOST = cr318530-a)(PORT = 1521))
(CONNECT_DATA =
(SERVICE_NAME = ORACLE8.WORLD)
What else do I need to do to connect?
null

When I try to connect from SQL*Plus delivered with 8i it works and the sqlnet.log shows the following info:
(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(HOST=cr318530-a)(PORT=1521)))(CONNECT_DATA=(SERVICE_NAME=ORACLE8.WORLD)(CID=(PROGRAM=D:\ORAW2K\BIN\SQLPLUSW.EXE)(HOST=CR318530-A) (USER=MD))))
When I try using other tools it fails and the sqlnet.log shows:
(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=BEQ)(PROGRAM=oracle80)(ARGV0=oracle80ORCL)(ARGS='(DESCRIPTION=(LOCAL=YES)(ADDRESS=(PROTOCOL=beq)))')))(CONNECT_DATA=(SID=ORCL)(CID=(PR OGRAM=D:\golden\GOLDEN32.EXE)(HOST=CR318530-A)(USER=MD))))
I don't know where the client is getting this information from. It used to be in the old tnsnames.ora in d:\orant\net80\admin but that has been replaced by the tnsnames from oracle8i.
Please email at [email protected] if you can help, I'm losing hope.
null

Similar Messages

  • Can I connect my form to a database to populate data?

    Can I connect my form to a database to populate data?

    Hi;
    You want to poplulate your form with data from a database, or to populate the database from the form?
    There isn't any way to import the data into the form in FormsCentral from a database.  To populate and external database from the table on the View Responses tab there are no APIs to do it automatically but you can export to Excel or CSV and then import the Excel or CSV into your database:  http://forums.adobe.com/docs/DOC-1383
    Thanks,
    Josh

  • Can't connect Forms 6i to Oracle 11g on Windows Server 2008 SE

    Hi everyone,
    I have Oracle 10g working pretty well with Forms 6i, but now I have installed Oracle 11g on another server and I'm trying to connect Forms 6i to my other Oracle 11g server, but Forms 6i never gets connected. Is there any trick to make it work? I have check the upper cases and other things related with lower and upper case passwords, but nothinh happens.
    Can anyone please help me?

    Hello;
    Its probably the Oracle client that installs with Forms 6. Try connecting to the database using SQL Plus from a Forms workstation. If it fails I would install a newer client and switch the Oracle Home on all the workstations.
    ( Provided it tests out )
    I would probably try using the Net Configurations Assistant in your Oracle Start Menu group with all combinations I could think of before I added a second client to the mix.
    Of minor interest :
    http://www.dbaportal.eu/?q=node/167
    The Windows version might put the hurt on you. This may or may not help that :
    http://www.araboug.org/ib/index.php?showtopic=49679
    Tough combination.
    Best Regards
    mseberg
    Edited by: mseberg on Jun 20, 2012 3:51 PM
    Later
    Legacy Applications and Oracle 11g
    http://jarneil.wordpress.com/2008/03/26/legacy-applications-and-oracle-11g/
    So I'm sorry to say you are out of options. I also checked the Forms Forum and the few posts there on Forms 6 ( Obsolete in 2004 ) all agree. Forms 6 and Oracle 11 database do not play together.
    I hope at least I saved you some time.
    mseberg
    Edited by: mseberg on Jun 20, 2012 4:36 PM
    Upgrading Oracle Forms 6i to Oracle Forms 11g
    http://docs.oracle.com/cd/E17904_01/doc.1111/e10394.pdf

  • How can i connect Forms 6i via OCA,

    Hi all,
    I have an application that need to connect in one process via ODBC to oracle lite, but i can't connect forms 6i to odbc, in sqlplus i put username/password@odbc:database and i connect, but when i try to connect forms or reports in these way it's gave me an error, but the error don't say nothing just the window appear, and don't have message. What i have to do in forms and reports?,
    Thanks.

    Could you then explain what your problem is?
    Frank has pointed you to a great source of information. What is it you don't understand.
    Generally speaking you just need to recompile the FMB file to regeneate the FMX - but if you are moving from client/server to web you may need to do some more changes (see the website).
    Regards
    Grant ROnald
    FOrms Product Management
    http://www.groundside.com/blog/content/GrantRonald/

  • Can I connect window device like modem, mobile in oracle forms,if possible then how?

    Can I connect window device like modem, mobile in oracle forms,if possible then how?

    Hi Tony,
    So explain where you would see your notification?I just mention, Leave module, there are many other module. For example In Purchase Purchase Requigition , Production Module Production Complite , Delivery Module Delivery Ready.
    For this it will better to show at respective Menu.
    In the Window title?Another good Idea !
    You could have a timer trigger that runs every 5 minutes and checks a notification table, if there is an unacknowledged notifcation, then you could change the Window title of the formas app to show a (1) at then end of it.Timer has a bad this.. For example, if i make a timer and run every 5 min. then if user works on a form, timer will hide the form and show the timer window.
    Isn't it ?
    Would that do, or do you need more?Yea.. More..It will be like facebook. If any notified work is done by any person, light will go off.
    Thanks for your interest and suggestion...
    Ask2Learn
    Edited by: Asked to Learn on Jan 23, 2013 12:36 AM

  • Oracle 6i Forms can't connect to Oracle XE Database(Linux)

    What is the problem, I can't connect my Oracle 6i Forms to Oracle XE Database that installed on Linux(Fedora Core 4/Ubuntu 6.06), but no problem when I try to connect to Oracle XE Database that installed on Windows.
    Thanks,

    See this thread, seem me interesting
    Re: Trouble to start Oracle XE listener
    on forms 10g it's work:
    using Database XE and Forms 10g
    and see too:
    http://www.oracle.com/technology/software/products/database/xe/htdocs/102xelinsoft.html
    http://www.oracle.com/technology/software/products/database/xe/files/install.102/b25144/toc.htm
    http://www.oracle.com/technology/tech/linux/install/xe-on-kubuntu.html
    Regards

  • I bought a used macbook pro from a friend. Software updates are available, but when I try to update, the computer asks for apple id and will only accept the former owner´s. How can I connect my macbook to my apple id?

    I bought a used macbook pro from a friend. Software updates are available, but when I try to update, the computer asks for apple id and will only accept the former owner´s. How can I connect my macbook to my apple id?

    The first thing you should do after acquiring a used computer is to erase the internal drive and install a clean copy of OS X. How you do that depends on the model. Look it up on this page to see what version was originally installed.
    If the machine shipped with OS X 10.4 or 10.5, you need a boxed and shrink-wrapped retail Snow Leopard installation disc, which you can get from the Apple Store or a reputable reseller — not from eBay or anything of the kind.
    If the machine shipped with OS X 10.6, you need the gray installation discs that came with it. If you don't have the discs, order replacements from Apple. A retail disc, or the gray discs from another model, will not work.
    To boot from an optical disc, insert it, then reboot and hold down the C key at the startup chime. Release the key when you see the gray Apple logo on the screen.
    If the machine shipped with OS X 10.7 or later, it should boot into Internet Recovery mode when you hold down the key combination option-command-R at the startup chime. Release the keys when you see a spinning globe.
    Once booted from the disc or in Internet Recovery, launch Disk Utility and select the icon of the internal drive — not any of the volume icons nested beneath it. In the Partition tab, select the default options: a GUID partition table with one data volume in Mac OS Extended (Journaled) format. This operation will permanently remove all existing data on the drive, which is what you should do.
    After partitioning, quit Disk Utility and run the OS X Installer. When the installation is done, the system will automatically reboot into the Setup Assistant, which will prompt you to transfer the data from another Mac, its backups, or from a Windows computer. If you have any data to transfer, this is usually the best time to do it.
    You should then run Software Update and install all available system updates from Apple. If you want to upgrade to a major version of OS X newer than 10.6, buy it from the Mac App Store. Note that you can't keep an upgraded version that was installed by the previous owner. He or she can't legally transfer it to you, and without the Apple ID you won't be able to update it in Software Update or reinstall, if that becomes necessary. The same goes for any App Store products that the previous owner installed — you have to repurchase them.

  • After update I can't connect to the internet in no way, shape or form

    I rarely update because: 1) something always breaks when you update (like now) and 2) I don't like to deal with new crap like GNOME 3. Anyway:
    I bought a new router (TL-WR1043N) and configured it with an old Ubuntu because connecting to 192.168.1.1 didn't work on any of my Arch Linux installations. Now... here's where it all starts... I can't use the 'n' wireless on my laptop since I have to install something to use WPA, and to install that I need to update, but I don't want to deal with GNOME 3 and Firefox >3. But I gave up eventually gave up and connected my laptop to the router by Ethernet cable. Setting that up was very easy: 'ifconfig eth0 up; dhcpcd'. Voila! I updated my whole system and restarted. To see how badly I damaged my system I opened Nautilus (I use Openbox with some GNOME programs): shock and dismay, the fonts are visible from the moon. I guess I'll have to quit using GNOME programs completely now but I expected that. I used to use KDE back in the day and when KDE4 came forth from that unholy pit, I immediately abandoned it for GNOME. This time we had more time to prepare, everybody knew what GNOME 3 was going to be. I started using Openbox quite a long time ago.
    Anyway: Now to fix my wireless right? WRONG! I can't connect to the internet on cable to get the packages for wireless. I installed Windows 7 64 on the same laptop and it connects to the cable. Ubuntu 9.10 Live also connects, but due to the changes of rc.conf and network stuff I can't connect at all with Arch Linux.
    So I decided to abandon it completely and reinstall from scratch. But the Live CD also doesn't work. With all the ways I've tried it all comes down to this:
    dhcpcd always times out waiting for a carrier and 'ip addr' shows 'eth0: <NO-CARRIER, ....' if the interface is up. I'm not sure what information I should give you, but I can't paste any here since I can't connect to the damn internet on that laptop.
    About the router: the cable is plugged on port 1 and the LED for it flashes if I reboot the computer. In Windows it stops flashing while it connects and flashes again when connected. I removed 'network' from DAEMONS and it flashes till I start it with '/etc/rc.d/network start'. This hangs for a while and returns '[DONE]' even though it doesn't work and the LED never flashes again on the router.
    In rc.conf I have exactly what the example says for DHCP. In any case, it doesn't work with the Live CD either.
    EDIT 1: From lscpi: painstakingly typed:
    06:00.0 Network controller: Intel Corporation PRO/Wireless 4965 AG or AGN [Kedron] Network Connection (rev 61)
    07:00.0 Ethernet controller: Realtek Semiconducctor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 01)
    EDIT 2: Just to be clear: I can use the wireless on the laptop on the Live CD, but I want to use the cable because of the greater speed (94Mbit/s on cable 60 something on wireless n, 20 something on g) and because I rarely move the laptop.
    EDIT 3: lspci -v shows "Kernel driver in use: r8169   /   Kernel modules: r8169", so the driver is loaded.
    EDIT 4: So if I boot from the CD. ip addr shows:
    eth: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN qlen 1000
        link/ether 00:1d:92:...etc... brd ff:ff:ff:ff:ff:ff
    And  the LED flashes. When I type: "ifconfig eth0 up" it stops, never to light up again and ip addr shows: "eth: <nO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc pfifo_fast state DOWN qlen 1000
    Last edited by imtired (2011-09-08 12:36:51)

    When you're in Arch, use output redirection
    lspci >lspci.out
    then boot into Ubuntu or something where you can access the files and the BBS,  Of course, don't forget to use a new file for each command output.
    The new network config in rc.conf is not that complicated (wired anyway; never used wireless).  OTOH I've had issues on two machines where I have to restart the network daemon (rc.d restart network) or rerun netcfg (netcfg eth0) after boot to get connectivity. And I still haven't come to grips with the ip command.

  • TS1398 Despite all my software are up to date, How can I connect to iTune? store. I can access itune store on my Mac( Lion ) but cant do the same form my iPhone that is synced with my Mac. Please help as I cant update my useful apps.

    Whenever I try to update my apps from my 4S iPhone it says " can not connect to iTune store.". I can do the same from my Mac PC with same password.

    Try logging out of your account on the iPhone by tapping on your id in Settings > Store and then log back in and see if it then works.

  • How can I connect to multiple routers in a homelab?

    Hello guys,
    I have a little little situation here maybe someone can give me a good ideea how to doit.
    I have 7 routers that I use for my homelab, what I want is a way to connect to all of them without having to change all the time the console cable from one to another.
    1. I know there is a way with IOLAN, but this is quite expensive
    2. I am thinking if there is a posibility to doit some how via telnet, something like this:
    Having all the AUX ports to a SW(maybe is necessary a router?!) and also my netcard in another port of the SW, and somehow to do a port forwarding when I telnet to ex. IP 10.0.0.1:4001 to redirect somehow the trafic to router 1 in the AUX.
    Is it possible something like this? Can i connect to AUX via a IP port somehow?
    What I am trying to do is to avoid using routers ETHs to assign to its IPs and connect like this via telnet, because I need to use that ports(interfaces) for other reasons.
    3. I've seen another whay with somekind of accessserver.. this is a special equipment?
    4. I can make a connection to one router with the console cable, and from that to make telnet from one to another, router by router, meaning from R1 to have telnet to R2, from R2 to have telnet to R1 and R3 .. and so on. (This is curently my implementation), but if I lose conectivity between 2 of the routers than this implementation is not viable
    5. Is there a easier way to do this?
    Thank You
    Ivian

    Hi Ivian
    What you are after is a Cisco 2509. They come in two forms. One has 8 RJ45 async serial ports which you can use to connect to the console ports of a router using a RJ45-RJ45 rollover cable. The other has a single AUI port which you can buy an octopus cable with 8 connections off it. It too can be used to connect to the console ports of up to eight devices.
    Here is some links which may help.
    http://www.cisco.com/en/US/tech/tk801/tk36/technologies_configuration_example09186a008014f8e7.shtml
    http://ciscotips.wordpress.com/2006/06/26/configuring-a-cisco-router-as-a-terminal-server/
    http://www.petri.co.il/how-to-configure-cisco-router-as-terminal-server.htm
    otherwise google "Cisco 2509 configure terminal server"
    The first link has the recommended Cisco config for your server.
    Cheers
    Donald
    CCNA

  • How can I connect my 30" HD Cinema Display to my XBox 360?

    Indeed, I presently own an old '30" Apple Cinema HD Display with Aluminum Enclosure,' in which I typically connect to my 15" Macbook Pro via a 'Mini DisplayPort to Dual-Link DVI Adapter'. I presently use it for my CG Design work and often for streaming movies online, but the big question now is: Can I connect my display to my XBox360?
    I've done a bit of digging already, and I've found a good amount of information regarding connecting my XBox to my Mac, so as to further run it through a window on my screen. Thing is, I don't want to connect it to my Mac to run it through my screen, I want to connect it to my screen!
    So, anyone? Anyone at all?
    Thanks,
    KaT

    I think (not sure since I don't have a UPS) it depends on the UPS and what the form of the power wave is (full sine wave, etc.).

  • Active Directory Services Can't Connect to Domain

    I removed Active Directory services form a server running 2012. I then went to reinstall and reconfigure it, but I keep running into issues. When I launch active directory admin center it gives me an error that it can't connect to any domain, and I can't
    make any changes. The local server has already been promoted to the domain controller. Here is the output from dcdiag:
    Directory Server Diagnosis
    Performing initial setup:
       Trying to find home server...
       Home Server = ACSSVR
       * Identified AD Forest. 
       Done gathering initial info.
    Doing initial required tests
       Testing server: Default-First-Site-Name\ACSSVR
          Starting test: Connectivity
             ......................... ACSSVR passed test Connectivity
    Doing primary tests
       Testing server: Default-First-Site-Name\ACSSVR
          Starting test: Advertising
             Fatal Error:DsGetDcName (ACSSVR) call failed, error 1355
             The Locator could not find the server.
             ......................... ACSSVR failed test Advertising
          Starting test: FrsEvent
             ......................... ACSSVR passed test FrsEvent
          Starting test: DFSREvent
             There are warning or error events within the last 24 hours after the
             SYSVOL has been shared.  Failing SYSVOL replication problems may cause
             Group Policy problems. 
             ......................... ACSSVR failed test DFSREvent
          Starting test: SysVolCheck
             ......................... ACSSVR passed test SysVolCheck
          Starting test: KccEvent
             A warning event occurred.  EventID: 0x80000B46
                Time Generated: 03/02/2015   12:00:00
                Event String:
                The security of this directory server can be significantly enhanced by configuring the server to reject SASL (Negotiate,  Kerberos, NTLM, or Digest) LDAP binds that do not request signing (integrity verification)
    and LDAP simple binds that  are performed on a cleartext (non-SSL/TLS-encrypted) connection.  Even if no clients are using such binds, configuring the server to reject them will improve the security of this server. 
             A warning event occurred.  EventID: 0x80000734
                Time Generated: 03/02/2015   12:00:37
                Event String:
                The local domain controller could not connect with the following domain controller hosting the following directory partition to resolve distinguished names. 
             ......................... ACSSVR passed test KccEvent
          Starting test: KnowsOfRoleHolders
             ......................... ACSSVR passed test KnowsOfRoleHolders
          Starting test: MachineAccount
             ......................... ACSSVR passed test MachineAccount
          Starting test: NCSecDesc
             ......................... ACSSVR passed test NCSecDesc
          Starting test: NetLogons
             Unable to connect to the NETLOGON share! (\\ACSSVR\netlogon)
             [ACSSVR] An net use or LsaPolicy operation failed with error 67,
             The network name cannot be found..
             ......................... ACSSVR failed test NetLogons
          Starting test: ObjectsReplicated
             ......................... ACSSVR passed test ObjectsReplicated
          Starting test: Replications
             ......................... ACSSVR passed test Replications
          Starting test: RidManager
             ......................... ACSSVR passed test RidManager
          Starting test: Services
             ......................... ACSSVR passed test Services
          Starting test: SystemLog
             A warning event occurred.  EventID: 0x000003F6
                Time Generated: 03/02/2015   11:21:34
                Event String:
                Name resolution for the name teredo.ipv6.microsoft.com. timed out after none of the configured DNS servers responded.
             A warning event occurred.  EventID: 0x000727A5
                Time Generated: 03/02/2015   11:21:58
                Event String:
                The WinRM service is not listening for WS-Management requests. 
             An error event occurred.  EventID: 0xC0001B58
                Time Generated: 03/02/2015   11:26:01
                Event String:
                The Vstor2 Virtual Storage Driver service failed to start due to the following error: 
             An error event occurred.  EventID: 0xC0001B58
                Time Generated: 03/02/2015   11:26:01
                Event String:
                The Vstor2 MntApi 2.0 Driver (shared) service failed to start due to the following error: 
             A warning event occurred.  EventID: 0x000003F6
                Time Generated: 03/02/2015   11:26:16
                Event String:
                Name resolution for the name teredo.ipv6.microsoft.com. timed out after none of the configured DNS servers responded.
             An error event occurred.  EventID: 0x0000002E
                Time Generated: 03/02/2015   11:34:32
                Event String:
                The time service encountered an error and was forced to shut down. The error was: 0x80070700: An attempt was made to logon, but the network logon service was not started.
             An error event occurred.  EventID: 0xC0001B6F
                Time Generated: 03/02/2015   11:34:32
                Event String:
                The Windows Time service terminated with the following error: 
             A warning event occurred.  EventID: 0x000727A5
                Time Generated: 03/02/2015   11:35:01
                Event String:
                The WinRM service is not listening for WS-Management requests. 
             A warning event occurred.  EventID: 0x000003F6
                Time Generated: 03/02/2015   11:39:08
                Event String:
                Name resolution for the name _ldap._tcp.dc._msdcs.ACS.local. timed out after none of the configured DNS servers responded.
             An error event occurred.  EventID: 0xC0001B58
                Time Generated: 03/02/2015   11:39:27
                Event String:
                The Vstor2 Virtual Storage Driver service failed to start due to the following error: 
             An error event occurred.  EventID: 0xC0001B58
                Time Generated: 03/02/2015   11:39:27
                Event String:
                The Vstor2 MntApi 2.0 Driver (shared) service failed to start due to the following error: 
             A warning event occurred.  EventID: 0x000727AA
                Time Generated: 03/02/2015   11:39:40
                Event String:
                The WinRM service failed to create the following SPNs: WSMAN/ACSSVR.ACS.local; WSMAN/ACSSVR. 
             A warning event occurred.  EventID: 0x0000000C
                Time Generated: 03/02/2015   11:39:39
                Event String:
                Time Provider NtpClient: This machine is configured to use the domain hierarchy to determine its time source, but it is the AD PDC emulator for the domain at the root of the forest, so there is no machine above it in
    the domain hierarchy to use as a time source. It is recommended that you either configure a reliable time service in the root domain, or manually configure the AD PDC to synchronize with an external time source. Otherwise, this machine will function as the
    authoritative time source in the domain hierarchy. If an external time source is not configured or used for this computer, you may choose to disable the NtpClient.
             A warning event occurred.  EventID: 0xC000042B
                Time Generated: 03/02/2015   11:42:01
                Event String:
                The RD Session Host server cannot register 'TERMSRV' Service Principal Name to be used for server authentication. The following error occured: The specified domain either does not exist or could not be contacted.
             An error event occurred.  EventID: 0x00000469
                Time Generated: 03/02/2015   11:44:31
                Event String:
                The processing of Group Policy failed because of lack of network connectivity to a domain controller. This may be a transient condition. A success message would be generated once the machine gets connected to the domain
    controller and Group Policy has successfully processed. If you do not see a success message for several hours, then contact your administrator.
             An error event occurred.  EventID: 0x00000469
                Time Generated: 03/02/2015   11:45:05
                Event String:
                The processing of Group Policy failed because of lack of network connectivity to a domain controller. This may be a transient condition. A success message would be generated once the machine gets connected to the domain
    controller and Group Policy has successfully processed. If you do not see a success message for several hours, then contact your administrator.
             An error event occurred.  EventID: 0x0000168F
                Time Generated: 03/02/2015   11:55:22
                Event String:
                The dynamic deletion of the DNS record 'ACS.acsolutionsinc.net. 600 IN A 192.168.56.1' failed on the following DNS server:  
             A warning event occurred.  EventID: 0x000003F6
                Time Generated: 03/02/2015   11:55:22
                Event String:
                Name resolution for the name acsolutionsinc.net timed out after none of the configured DNS servers responded.
             An error event occurred.  EventID: 0x0000168F
                Time Generated: 03/02/2015   11:55:47
                Event String:
                The dynamic deletion of the DNS record '_ldap._tcp.ACS.acsolutionsinc.net. 600 IN SRV 0 100 389 ACSSVR.ACS.acsolutionsinc.net.' failed on the following DNS server:  
             A warning event occurred.  EventID: 0x000727A5
                Time Generated: 03/02/2015   11:55:53
                Event String:
                The WinRM service is not listening for WS-Management requests. 
             A warning event occurred.  EventID: 0x000003F6
                Time Generated: 03/02/2015   11:55:53
                Event String:
                Name resolution for the name _ldap._tcp.Default-First-Site-Name._sites.dc._msdcs.ACS.local. timed out after none of the configured DNS servers responded.
             A warning event occurred.  EventID: 0x000003F6
                Time Generated: 03/02/2015   11:59:53
                Event String:
                Name resolution for the name _ldap._tcp.dc._msdcs.ACS.local. timed out after none of the configured DNS servers responded.
             An error event occurred.  EventID: 0xC0001B58
                Time Generated: 03/02/2015   12:00:13
                Event String:
                The Vstor2 Virtual Storage Driver service failed to start due to the following error: 
             An error event occurred.  EventID: 0xC0001B58
                Time Generated: 03/02/2015   12:00:13
                Event String:
                The Vstor2 MntApi 2.0 Driver (shared) service failed to start due to the following error: 
             A warning event occurred.  EventID: 0x000727AA
                Time Generated: 03/02/2015   12:00:25
                Event String:
                The WinRM service failed to create the following SPNs: WSMAN/ACSSVR.ACS.local; WSMAN/ACSSVR. 
             A warning event occurred.  EventID: 0x0000000C
                Time Generated: 03/02/2015   12:00:25
                Event String:
                Time Provider NtpClient: This machine is configured to use the domain hierarchy to determine its time source, but it is the AD PDC emulator for the domain at the root of the forest, so there is no machine above it in
    the domain hierarchy to use as a time source. It is recommended that you either configure a reliable time service in the root domain, or manually configure the AD PDC to synchronize with an external time source. Otherwise, this machine will function as the
    authoritative time source in the domain hierarchy. If an external time source is not configured or used for this computer, you may choose to disable the NtpClient.
             A warning event occurred.  EventID: 0xC000042B
                Time Generated: 03/02/2015   12:02:47
                Event String:
                The RD Session Host server cannot register 'TERMSRV' Service Principal Name to be used for server authentication. The following error occured: The specified domain either does not exist or could not be contacted.
             An error event occurred.  EventID: 0x00000469
                Time Generated: 03/02/2015   12:05:17
                Event String:
                The processing of Group Policy failed because of lack of network connectivity to a domain controller. This may be a transient condition. A success message would be generated once the machine gets connected to the domain
    controller and Group Policy has successfully processed. If you do not see a success message for several hours, then contact your administrator.
             An error event occurred.  EventID: 0x00000469
                Time Generated: 03/02/2015   12:05:17
                Event String:
                The processing of Group Policy failed because of lack of network connectivity to a domain controller. This may be a transient condition. A success message would be generated once the machine gets connected to the domain
    controller and Group Policy has successfully processed. If you do not see a success message for several hours, then contact your administrator.
             ......................... ACSSVR failed test SystemLog
          Starting test: VerifyReferences
             ......................... ACSSVR passed test VerifyReferences
       Running partition tests on : Schema
          Starting test: CheckSDRefDom
             ......................... Schema passed test CheckSDRefDom
          Starting test: CrossRefValidation
             ......................... Schema passed test CrossRefValidation
       Running partition tests on : Configuration
          Starting test: CheckSDRefDom
             ......................... Configuration passed test CheckSDRefDom
          Starting test: CrossRefValidation
             ......................... Configuration passed test CrossRefValidation
       Running partition tests on : ACS
          Starting test: CheckSDRefDom
             ......................... ACS passed test CheckSDRefDom
          Starting test: CrossRefValidation
             ......................... ACS passed test CrossRefValidation
       Running enterprise tests on : ACS.local
          Starting test: LocatorCheck
             Warning: DcGetDcName(GC_SERVER_REQUIRED) call failed, error 1355
             A Global Catalog Server could not be located - All GC's are down.
             Warning: DcGetDcName(TIME_SERVER) call failed, error 1355
             A Time Server could not be located.
             The server holding the PDC role is down.
             Warning: DcGetDcName(GOOD_TIME_SERVER_PREFERRED) call failed, error
             1355
             A Good Time Server could not be located.
             Warning: DcGetDcName(KDC_REQUIRED) call failed, error 1355
             A KDC could not be located - All the KDCs are down.
             ......................... ACS.local failed test LocatorCheck
          Starting test: Intersite
             ......................... ACS.local passed test Intersite
    I've been trying to debug errors one at a time, but I'm having a hard time finding any information that pertains to this issue as a whole. Anything you can tell me about this would be great, thank you for reading. 

    It was the only server in the network, the only dc in the old forest. When I re-installed ad ds I gave the new forest different name, but I guess the old settings are still in the system somewhere conflicting with the new setup? Is there a way to
    purge the old setup entirely and start over with ad ds, or am I going to have to re-install the whole OS? Thanks again for the help.
    Honestly, the best way to handle this is to rebuild the server. There are many things that are "left behind" when you remove the Domain / Forest from a Domain Controller. In fact many articles will say after using ADMT (active directory migration
    tool) you should decommission the original Domain Controller (aka reinstall the OS).
    While you could spend more time trying to get that domain controller working, it absolutely is going to be 1) More reliable 2) faster to reinstall the OS on the old domain controller. If you are still leveraging storage, or services on that domain controller,
    you will want to back them up, or have a transition plan before reinstalling everything on the server. I have a feeling if you choose to keep troubleshooting this, you will run into more issues down the road.
    Entrepreneur, Strategic Technical Advisor, and Sr. Consulting Engineer - Strategic Services and Solutions Check out my book - Powershell 3.0 - WMI: http://amzn.to/1BnjOmo | Mastering PowerShell Coming in April 2015!

  • Can't connect to router's admin interface (WRT54G v3.1)

    Hi.
    I have problem with my Linksys WRT54G v3.1 router. I can't connect to its admin interface and broadband Internet connection doesn't work.
    The power LED is flashing. When I restart the router or unplug and plug it again, nothing happens. The power LED just continue to flash and I can't connect to the router. I even tried to put new firmware but program that I downloaded from linksys.com can't connect to the router.
    When I enter http://192.168.1.1 into Firefox or Explorer, I get "Connecting to http://192.168.1.1..." and nothing else happens.
    I hope that someone can help me because it's pretty annoying that my home network doesn't work...
    Thank in advance, Sasha.Message Edited by k31k0 on 12-26-200603:27 AM
    Message Edited by k31k0 on 12-26-200603:28 AM

    Sounds like your router is bricked, flashing power LED is not good.  Contact the RMA department and explain whats going on.  Your router has the Linux operating system.  When you talk to them make sure you mention this and you want the same router as a replacement which is the WRT54GL.  If you dont specify that you want the same they will send you a version 6.  Then you are looking at more headaches.
    In the RMA form you have to add "ONLY" to the version box on the RMA form. That's because most customers prefer the latest if they have it, and they try to accommodate as much as possible. Rarely is there a need for a specific version.
    Message Edited by wehowardjr on 12-26-200607:00 AM

  • Can i connect an external signal generator to the NI7344 to...

    Can i connect an external signal generator to the NI7344 to use its
    PID characteristics to precisely control the output
    I am using the flex motion board (NI7344) to control the force output
    of a linear motor. Using contouring and buffer operations i have
    successfully created a system which can output a controlled force
    which sinusoidal in form. I can achieve a reasonable output for
    waveforms of 10Hz, the use of higher frequencies is limited by the
    contouring operation ( a frequency of 10 Hz means i can only describe
    one period of a sine wave with 10 points ( 10ms between each point =
    10Hz). Can i therfore connect an external anologue wave generator to
    the NI7344 use and use its PID characteristics to output wave
    forms of
    higher frequency ??? .....could i output an anolgue wave form from an
    E-series DAQ via the RTSI cable to the NI7344 and control this ???.any
    ideas or advice would be much appreciated.

    Duncan,
    You can use a DAQ card to output an analog waveform, but it will be a software call not part of an onboard program. RTSI can be used to pass clocks and trigger signals, so if you want to route a clock signal to do the control you could.
    A. Talley

  • How can i connect to another dataset?

    Post Author: anmelder
    CA Forum: Data Connectivity and SQL
    Hi,first, sorry for my bad english. I try to explain my problem:I generated a project (VS 2005, VB) for testing CR and doing first steps. the report i designed was connected to a dataset, which i designed in designtime. The report works fine, and now i try to use it in my really project. In this project i use only datasources generated on runtime. The dataset I want to connect to the report has the same tables, the same fields like the dataset in my testing-project, but i can established a connection. Every time i got an window to sign in a database. My code:&#91;Code&#93;    Dim ds_temp As New DataSet    Dim daT As New SqlClient.SqlDataAdapter("SELECT * FROM ...", My.Forms.Form1.sqlConn)    Dim daK As New SqlClient.SqlDataAdapter("SELECT ... FROM ...", My.Forms.Form1.sqlConn)    Dim daP As New SqlClient.SqlDataAdapter("SELECT ... FROM ...", My.Forms.Form1.sqlConn)    daT.Fill(ds_temp, "Termine")    daK.Fill(ds_temp, "kunden")    daP.Fill(ds_temp, "personal")    Dim rp As New crepTechnikerEinsaetze  ' the report    rp.SetDatabaseLogon("", "")    rp.SetDataSource(ds_temp) '.Tables(0))    Dim logonInfo As New TableLogOnInfo()    For Each t As CrystalDecisions.CrystalReports.Engine.Table In rp.Database.Tables      logonInfo = t.LogOnInfo      logonInfo.ConnectionInfo.ServerName = "ds_temp"         'logonInfo.ConnectionInfo.UserID = ""      'logonInfo.ConnectionInfo.Password = ""      logonInfo.ConnectionInfo.IntegratedSecurity = True      logonInfo.ConnectionInfo.DatabaseName = ""      t.ApplyLogOnInfo(logonInfo)    Next    CrystalReportViewer1.ReportSource = rp &#91;\Code&#93;How can I connect to my DataSet generated in runtime? And how can I design Reports, if I only use Datasets generated in runtime?I would be very happy for every help. I try it since 3 days now, and i cant solve this. Thank you ... 

    No. What you want to do isn't possible.

Maybe you are looking for

  • Ovi Store Application NOT WORKING

    I've been experiencing this problem for a while already. Probably like many other users, I could not access Ovi store via its application. Everytime I open it, there's a error script saying " Application Initialisation Failed" I'm using Nokia 5800 Xp

  • How can I retrieve my photos and videos after pressing 'delete from everywhere' accidentally on my iPhone 4s?

    Hello all, So I was organising my photos and videos on my iPhone 4s and wanted to delete them from my camera roll once I had moved them to new folders. When I tried to delete them from my camera roll it asked if I wanted to 'delete from everywhere'.

  • How to give own field  name in alvgrid

    how to give own field name in alvgrid CLEAR LS_FIELDCAT.   LS_FIELDCAT-TABNAME       = G_TABNAME.   LS_FIELDCAT-FIELDNAME     = 'KBETR'.   LS_FIELDCAT-REF_FIELDNAME = 'KBETR'.   LS_FIELDCAT-REF_TABNAME   = 'KONV'.   APPEND LS_FIELDCAT TO  RT_FIELDCAT

  • ULaw compression for the Mac? Anyone heard of this?

    I have a client that requires his recording for phone system be in 8k 8-bit uLaw format. Totally a PC thing, I know. I am trying to see if there is a filter or way of creating his recordings in ulaw on the Mac. Can anyone provide some help? Thanks, P

  • Development of screens

    I have around 100-200 remote users connecting to my database and these users will be accessing my custom made screens.Can you suggest me the best way of approach,I don't want to use JIntiator as my users use very low speed modems to dial up to my dat