FP default-values and diagram "constants" can change in LabVIEW 6.1 and 7.1

Hi Folks,
      I'm posting here [instead of bug report] first, in case this isn't really a bug.
I created a bunch of similier VIs with type-def cluster inputs, and, on each VI, gave the clusters a default-value.  I'm finding that when these typedefs are changed by removing an element, the default FP values are corrupted.  In my case it gets worse.  When I used these VIs on diagrams, I frequently created a cluster-constant - derived from the VI's cluster-control (described above.)  The remaining elements in the diagram-"constants" are also changing.
Regards
P.S.  Sorry if topic has already been discussed! (I did search a "bit", first...)   
Message Edited by Dynamik on 10-28-2005 10:44 PM
When they give imbeciles handicap-parking, I won't have so far to walk!
Attachments:
Untitled12.vi ‏17 KB
Untitled.ctl ‏7 KB

This sounds like it could be a bug AND normal operation.
There are bugs in LV 7.1, 7.0 and possibly earlier that cuases LV to choose the wrong value when bundling and un-bundling by name.
I have been told these are fixed in LV 8.0
See this thread for more details on the bug.
http://forums.ni.com/ni/board/message?board.id=170&message.id=105455&jump=true
Now as far as the constants that are based on the typedef changing, tht is normal behaviour. As Odd_Modem mentioned, doing an explicit bundle by name is the way to handle this. If you use the same "constant" repeatedly in your code, a sub-VI that does the bundling makes your code a lot easier to read.
Here is a code snippet
and the source for that example can be ound in this thread.
http://forums.ni.com/ni/board/message?board.id=170&message.id=148471#M148471
Ben
Message Edited by Ben on 10-29-2005 10:42 AM
Ben Rayner
I am currently active on.. MainStream Preppers
Rayner's Ridge is under construction

Similar Messages

  • I want to set a variable with default value and can be changed by the user

    hi,
    i want to set a variable with default value and can be changed by the user, so i new a variable with setting : customer exit, single value, optional, ready for input.
    in my customer exit code, i set a default value, eg. 20070530
    when the variable screen popup, it display the default value 20070530, i changed it to 20070529, but it doesn't work , it still display the data in 20070530, how can i solve this problem? 
    your help is appreciated.

    Liu,
       As mentioned by Anil, you need to restrict your customerr Exit code to I_STEP = 1.
    or.
       <u>Open your Variable in change mode, in the Last Page os the Variable Maintenance you can provide default value. Note: you are doing same thing in Customer Exit. In your case no need of Customer Exit.</u>
    Nagesh Ganisetti.
    Assign points if it helps.

  • SSRS 2008 R2 Report parameters have default values and report not to auto run

    Hi, I am using SSRS 2008 R2 one of my requirements for a Report is all the parameters have default value and I do not want this report to auto run when users open this report. I can create a dummy hidden parameter to break the auto run for this
    report. But I am looking for solutions other than that.
    Thanks in advance..........
    Ione

    Hi lone,
    According to your description, you have a report with parameters. Now you want you report not to run automatically with your parameters default values. Right?
    In Reporting Service, if you have parameters with default values in your report, your report will always auto run with these default values. We can say these default values are used for report running initially. So for your requirement, if you really need
    to see your default value before the report running, the best workaround is set one more parameter to break the auto run like you have done. If you just want your report not to auto run, your can achieve it by removing those default values.
    Reference:
    Report Parameters (Report Builder and SSRS)
    If you have any question, please feel free to ask.
    Best Regards,
    Simon Hou (Pactera)

  • How to set default value and bg color of cross tab cell?

    Hi all
    Which way can I set default value and background color for a crosstab cell where there are no any data?
    I try to pass it in following way
    if isnull(CurrentFieldValue) then
    But is has no effect.

    Hi,
    If your field is numeric
    if currentfieldvalue =0 then cryellow else crnocolor
    if the field is numeric but you don't see the 0 check check if : Suppress if zero is ticked in the Number format tab.
    Regards

  • Crystal Reports scheduling disregard the default values and requires prompts to be answered every time.

    Hi guys,
    When scheduling a Crystal report, the page to configure the prompt answers does not have any prompts answered by default - they all appear as "[EMPTY]". This means that any required prompts must be answered during configuration of the alert schedule. Since prompt is required and the default value (which is equivalent to not answering the prompt) is not available in the selection list.
    Is there any way around it?
    Ideally I would like the prompts to keep the default values, so I could schedule the report for all the prompt answers (Whole list of value) instead of having at least one prompt value.
    Is there any configuration in crystal reports or on database side that could help me resolve the issue.

    First off, Thank you for your replies!
    Rabeb SLIMANI, we can't use universes by user requirement. If we could, it would have to be through IDT (Information Design Tool) but, nonetheless, the users want a direct BICS connection between BEx and WebI.
    Victor Gabriel Saiz Castillo, we can't do that because the users want to choose between accessing the published instances or refreshing the reports on demand.
    The way i see it, it would take a second set of BEx query + WebI report to provide both functionalities (one for ready for input, another for not ready for input). Am I correct?
    @Sathish Kumar (sorry, i can't tag you right), i was checking with the BW team and we already have the logic for If left null, populate with Customer Exits.
    But they are currently mandatory, so we will change them to optional and test the behavior.
    If you have any other ideas, they are more than welcome! I will keep you posted on the outcome!
    Best regards,
    Francisco

  • ORA-01400 - not null column with default value and item with authorization

    I've searched - I would think someone has run into this. APEX 3.0.0.00.20 - I've created a simple form on a table. One of the column is a not null column with a default value. I have a select list on that item, but it has security on it - authorization scheme. So, it checks the user and if that user isn't of the right role, it will not even display that item. However, APEX appears to still send in the column in its sql! So, the default value is useless, it sends in null each time. Even if I set the default at the Item level, I get null. Argg. That's got to be a bug...
    In debug, I do not see the item listed at all. It's not used. That's fine - but why is it trying to insert the value? I would think it would leave it off??? I think because the item is associated with a database column. But, getting around this is ugly. Having to create a hidden item for each one, and then check to see if I need to take the list value... horrible. Any way to get around this???

    I should add - I guess I can always put my own custom process in to replace the DML. Just seems like a simple thing - if the value doesn't appear on the debug, isn't set with any default value... don't include it in the DML.

  • How to Assign a default value and Increement in my Target table ........?

    Hi,
    In my target table I want to Increment a value and store it in the table ........
    the increement shud start frm ...........5001,5002,5003..................etc
    How can I achieve this...........?
    I created an numeric Variable and in assigned the default as 5000 nad action as Historize.........
    In the target Datastore ......I assigned VAR+1.......
    but in the Target column I got 5001 for all the columns........
    Which way is the best way to deal with the Variables.......
    Thanks
    AK
    Message was edited by:
    AK2008

    Hi Gurusank and Micropole,
    Thanks for reply and info.....
    I am trying out one of the solutions first........
    Gurusank,
    I have created a sequence........whether I need to mention the schema and table name ,column.........also ( I gave all the information) and Increement column =1 and saved it .......
    Then I follwed the procedure as u have mentioned .....
    And in the Target field also I gave the same the same.......for tat column I gave choose (target for execution).
    And I directly ran the interface ..........
    I got the folowing Error:
    287 : 42000 : java.sql.SQLException: ORA-02287: sequence number not allowed here
    java.sql.SQLException: ORA-02287: sequence number not allowed here
         at oracle.jdbc.driver.DatabaseError.throwSqlException(DatabaseError.java:125)
         at oracle.jdbc.driver.T4CTTIoer.processError(T4CTTIoer.java:316)
         at oracle.jdbc.driver.T4CTTIoer.processError(T4CTTIoer.java:282)
         at oracle.jdbc.driver.T4C8Oall.receive(T4C8Oall.java:639)
         at oracle.jdbc.driver.T4CPreparedStatement.doOall8(T4CPreparedStatement.java:185)
         at oracle.jdbc.driver.T4CPreparedStatement.execute_for_rows(T4CPreparedStatement.java:633)
         at oracle.jdbc.driver.OracleStatement.doExecuteWithTimeout(OracleStatement.java:1086)
         at oracle.jdbc.driver.OraclePreparedStatement.executeInternal(OraclePreparedStatement.java:2984)
         at oracle.jdbc.driver.OraclePreparedStatement.executeUpdate(OraclePreparedStatement.java:3057)
         at com.sunopsis.sql.SnpsQuery.executeUpdate(SnpsQuery.java)
         at com.sunopsis.dwg.dbobj.SnpSessTaskSql.execStdOrders(SnpSessTaskSql.java)
         at com.sunopsis.dwg.dbobj.SnpSessTaskSql.treatTaskTrt(SnpSessTaskSql.java)
         at com.sunopsis.dwg.dbobj.SnpSessTaskSqlI.treatTaskTrt(SnpSessTaskSqlI.java)
         at com.sunopsis.dwg.dbobj.SnpSessTaskSql.treatTask(SnpSessTaskSql.java)
         at com.sunopsis.dwg.dbobj.SnpSessStep.treatSessStep(SnpSessStep.java)
         at com.sunopsis.dwg.dbobj.SnpSession.treatSession(SnpSession.java)
         at com.sunopsis.dwg.cmd.DwgCommandSession.treatCommand(DwgCommandSession.java)
         at com.sunopsis.dwg.cmd.DwgCommandBase.execute(DwgCommandBase.java)
         at com.sunopsis.dwg.cmd.e.i(e.java)
         at com.sunopsis.dwg.cmd.g.y(g.java)
         at com.sunopsis.dwg.cmd.e.run(e.java)
         at java.lang.Thread.run(Thread.java:534)
    Could u plz let me know where I am doing the mistake
    Thanks
    AK

  • How to set default value and after that , use it as control

    Hello,
    Currently i am making motor driver from labview, and i am facing one problem.
    When i connect to my board via labview, it will relay last position to global variable. After that, i have to go to loop, where i can send back  modified position to my motor control board
    In short, i have to control number, but that number default value should be writtem by another function when i start vi.
    any ideas how to do it ?
    Solved!
    Go to Solution.

    Let me know if any clarification is needed
    Kudos are always welcome if you got solution to some extent.
    I need my difficulties because they are necessary to enjoy my success.
    --Ranjeet
    Attachments:
    VI.vi ‏13 KB

  • Bex Query Default values and warning

    Hi,
    I noticed that if I use DEFAULT VALUES (ex. I set a CostCenter on a fixed default value), when I launch the query a warning like "the costcenter characteristic haven't a base date for XXXX" (XXXX is the value I fix).
    I don't understand why this message appears and how to avoid it. I also tried to set the key date on the query but the result is the same.
    The costcenter is a characteristic that has a time dependent master data.
    Any idea?
    Thanks for the support!

    Hi Maresca ,
    I am not completely sure as to why the warning message appers, but you can avoid the warning messgae by suppressing it in the transaction RSRT.
    After going to the transaction RSRT, you can give the query's technical name , and click on the 'Messages' tab. Here you can supress the warning message. Each message has a message number which can be found by clickin on it, and you can check the message brain number and supress it.
    Hope this helps !
    Regards
    Snehith

  • Select options default value and execute

    Hello,
    I managed to fill my select options default value. But what I also want is that the user does not have to press the execute button when the screen is shown at the first time. I would like to show the result screen for these default values at the same time the screen is shown first.
    I tried in WDDOINIT:
      data: l_ref_interfacecontroller type ref to iwci_wdr_select_options .
      l_ref_interfacecontroller =   wd_this->wd_cpifc_select_options( ).
      l_ref_interfacecontroller->execute(
    but this coding only works when the select-option screen was shown the first time.
    Any ideas?
    regards
    stefan

    Hello Sascha,
    I checked that WD_THIS->MR_SELOPT is filled.
    My coding in WDDOINIT is:
    *--- Instantiate select options component
      lr_usage = wd_this->wd_cpuse_usage_so( ).
      if lr_usage->has_active_component( ) is initial.
        lr_usage->create_component( ).
      endif.
    *--- Initialize selection screen
      lr_if_controller = wd_this->wd_cpifc_usage_so( ).
      wd_this->mr_selopt = lr_if_controller->init_selection_screen( ).
    *--- Configure layout options
      wd_this->mr_selopt->set_global_options(
                                 i_display_btn_cancel  = abap_false
                                 i_display_btn_check   = abap_false
                                 i_display_btn_reset   = abap_true
                                 i_display_btn_execute = abap_true ).
    *--- Create range tables
      lt_range = wd_this->mr_selopt->create_range_table(
                                                       i_typename = 'DATUM' ).
    *Range vorbelegen
      wa_dats = sy-datum - 30.
      wa_range_datum-sign = 'I'.
      wa_range_datum-option = 'BT'.
      wa_range_datum-low = wa_dats.
      wa_range_datum-high = sy-datum.
      assign lt_range->* to <fs_rangetable>.
      create data r_headerline like line of  <fs_rangetable>.
      assign r_headerline->* to <fs_range>.
      move-corresponding  wa_range_datum to <fs_range>.
      append <fs_range> to <fs_rangetable>.
      wd_this->mr_selopt->add_selection_field( i_id        = 'DATUM'
                                               it_result   = lt_range ).
      lt_range = wd_this->mr_selopt->create_range_table( i_typename = 'UZEIT' ).
      wd_this->mr_selopt->add_selection_field( i_id        = 'UZEIT'
                                               it_result   = lt_range ).
      lt_range = wd_this->mr_selopt->create_range_table( i_typename = 'UNAME' ).
      wd_this->mr_selopt->add_selection_field( i_id        = 'UNAME'
                                               it_result   = lt_range
                                               i_no_intervals = 'X'
                                               i_no_extension = 'X' ).
    data: event type ref to cl_wd_custom_event.
    create object event
      exporting
        name   = 'EXECUTE'
       parameters =
      wd_this->search_sel_opt(
        wdevent =    event                       " Ref to cl_Wd_Custom_Event
    Maybe you can see my mistake?
    regards
    stefan

  • Initializu00EDng select options field with default values and with NO INTERVALS

    Dear All,
    I have used WDR_SELECT_OPTIONS technology within WD Abap.
    I also have added the fields which have to be taken into consideration.
    lt_range_table =
    wd_this->m_handler->create_range_table(
    i_typename = 'PLANT' ).
    wd_this->m_handler->add_selection_field(
    i_id = 'PLANT'
    it_result = lt_range_table
    i_read_only = read_only ).
    Can I assign two values to this field 'PLANT' whereby the user may take only these values.
    I mean kind of pre initializíng of this select options field with default values.
    Due to this handling it should be prevented that the user can give other values
    except this values.
    Additonally it should be fine whether it is possible to disable the second input field
    of this select options field like NO INTERVALS .
    Regard
    sas
    Regard
    sas

    wd_this->m_handler->add_selection_field(
    i_id = 'PLANT'
    it_result = lt_range_table
    I_NO_INTERVALS = 'X'
    i_read_only = read_only ).
    Pls check 'WDR_TEST_SELECT_OPTIONS' web dynpro component

  • Default values and other questions about MIO-PCI-16E-1

    Hi, I have a few questions involving the above mentioned board.
    First: When doing a data acquisition using an external digital trigger and an external clock, which edge of the clock signal is read by default?
    What is the delay between a STARTSCAN signal being received and a CONVERT signal being generated (signifying an ADC convertion taking place?)
    Finally, what exactly is the sample interval counter? What does it do? This is mentioned on page 4-32 in the E Series DAQ user manual.
    Hopefully these questions aren't too stupid We're designing some custom circuitry to work with the DAQ, and for things to work the timing must be precise. We need ALL the timing details about a single data acquisition t
    hat we can get.
    The system we're running on has Labview 6.0.2, and we are only acquiring data from one analog input.
    Thanks a ton!
    --Randall Cameron

    Hey Randall,
    The internal Scan Clock is a rising edge clock, if you are interested in having the rising edge clock output as high until a scan is complete, please refer here. The internal Convert Clock is always falling edge clock.
    If you are using an external signal, you can specify the polarity of the signal by selecting PFI pin, high to low, or low to high, if you are using the Clock Config VI. The method for setting the polarity changes based on the method of programming the card. And again, I do not know what the digital trigger defaults to, but you can select either polarity.
    The delay between a Scan and a Convert is based on the Convert Clock.
    Ideally, the delay is in the nanosecond range, and then the Convert Clock determines the spacing between any further samples.
    As for the sample interval counter, the following is pasted from page 4-35.
    �The sample interval counter on the PCI E Series device normally generates
    the CONVERT* signal unless you select some external source. The counter
    is started by the STARTSCAN signal and continues to count down and
    reload itself until the scan is finished. It then reloads itself in preparation for
    the next STARTSCAN pulse.�
    So just let us know if you have any questions on getting the polarity set up, or if anything is not fully explained.
    Best regards,
    Justin T.
    National Instruments

  • Defaulting Values and Read-Only Items?

    Hi All,
    Brand new to APEX and trying to think of ways to get a few things working for me hoping you might have some suggestions.
    1. Want to have a few items default upon the creation of a record.
    - Created Date - have a column/page item that I would like to default/auto populate with the current date
    - Create by - would like to have column/page item default with the login id of the user
    2. Dynamically make page/items read-only.
    - Once a record is created I would like to ensure that the only person able to edit the record would be the creator. I assume I can use the Read Only feature at the item level but am unsure of the syntax to use to make the item read-only for only the user who created/or is creating the record. Since I would like to be defaulting the "Create by" (see question 1) column to the login id of the user this should be plausible just not sure of the syntax to reference the current user id.
    3. Passing a value to to bind variable.
    - I have build a basic page with an Interactive Report and have made one of the columns in the Interactive report 'linkable' which launches a BI Publisher report by calling a Report Query. Currently in my report query I have hard coded a value in the SQL statements where clause to prove the theory works what I am struggling with is a declarative way to pass the value that I am clicking to a bind variable in my SQL statements where clause in the query.
    Thanks in advance for any suggestions and appreciate your patience with an APEX newbie .. about 2 days old at this juncture. The more specific you can be on what to do and where to go is greatly appreciated.
    For those interested in have greater control with your report layout BI Publisher looks to be a great options. I was able to getting by reviewing [how to document:|http://www.oracle.com/technology/products/database/application_express/howtos/howto_master_detail_pdf.html] on OTN. My challenge some in the fact that rather then simply being on the exact row that I want reported on I would like to simply click on a link in a list and pass that value as the bind variable.
    JES

    Hi -
    "1. Want to have a few items default upon the creation of a record."
    This is typically done in a trigger at the db level.
    CREATE OR REPLACE TRIGGER mytrigger
    BEFORE INSERT OR UPDATE
    ON mytable
    REFERENCING NEW AS new OLD AS old
    FOR EACH ROW
    BEGIN
      if (:new.CREATED_DATE is null)
        then
          :new.CREATED_DATE := sysdate;
        end if;
      if (:new.CREATED_USER is null)
        then
          :new.CREATED_USER := nvl(v('APP_USER'),user);
        end if;
      :new.UPDATED_DATE := sysdate;
      :new.UPDATED_USER := nvl(v('APP_USER'),user);
    END CREATE OR REPLACE TRIGGER mytrigger;"2. Dynamically make page/items read-only."
    See 'APP_USER' in the Apex docs...
    "3. Passing a value to to bind variable."
    This is done in the report configuration in the Apex UI...
    Session State Include application and session information.
    You might want to consider reviewing some of the Apex docs and tutorials, I recommend this:
    [http://download.oracle.com/docs/cd/E14373_01/appdev.32/e13367/toc.htm]
    Good luck.

  • How can I set default value to a transient parameter  in the VO

    I have created a transient parameter in the VO, which is type of boolean.
    When I try to input the "true" or "True" or "Y" in the 'default value',
    and then running the programm, but all failure.
    so I don't know how can i do.
    Genuinely waiting for you help, thanks in advance.

    Hi Sumury,
    First of all you could check if this transient attribute is read only. to check this, edit the VO and select the transient attribute under the Attributes tab. Then verify if it is marked as "Updateable Always" on the right-hand section.
    If it is updateable, then try setting the default value on the VO Implementation class: open the xxxVOImpl class, go to the transient attribute's setter (setxxx()) and change it to:
    <code> if (getXXX() == null) setAttributeInternal(XXX, "Y");
    else setAttributeInternal(XXX, value);</code>
    This might work. If it does not, then please post the exact message you are receiving when running the app.
    Hope this helps!
    Thiago

  • Control/Default values in Service Notifications and Service Orders

    Hi all,
    When in transaction IW52 and IW32 I know you can maintain a set of default values for when you are either creating a Service Notificaiton and/or a Service Order.
    My scenario is as follows:-
    User 1 has a set of default values and it contains Work Centre A.  User 1 then creates a Service Notification.
    User 2 has a set of default values and it contains Work Centre B.  User 2 then reviews the Service Notification created by User 1 and wishes to create a Service Order.
    When User 2 creates the Service Order, the default value for the Work Centre is using User 1's Work Centre (Work centre A) and not their own Work Centre of Work Centre B?
    What is stopping User 2 picking up their own Work Centre of Work Centre B when they want to create a Service Order from a Service Notification?

    Gary,
    The order takes its data from the notification (which got it from USER1's defaults).
    What you need to do is change the notification work centre to that of USER2's preferred default value.
    There is no standard setting for this. However, all is not lost. It may be possible by misuing one of the order user-exits
    PeteA

Maybe you are looking for

  • Finder has gone from slow to nearly unresponsive!!!

    I have owned a 2.16 GHz Intel Core 2 Duo MacBook Pro with 2GB of RAM for about a year and upgraded to Leopard the week that it was released, and I had no problems with it off the bat; in fact, my system ran as well as it had in months once I first in

  • TV@nywhere Plus Cable problem

    Hello folks... I have recently gotten a TV@nywhere Plus card and installed it in my machine.  It scans for channels and seems to find them, but the picture quality is terrible.  However,  If I choose antenna as the input it picks up the channels 2 to

  • "Import Mailboxes" can't see IMAP inbox in backup Mail folder

    So, a friend of mine thought he'd be efficient and, via the webmail interface, deleted all the messages in the Inboxes of two IMAP accounts (hosted by Fatcow). He did not understand that this would delete all the messages in the inboxes on his comput

  • Health Service in which the location monitoring object is contained is not available

    Hello, When i am trying to discover new machines I am getting this error: Health Service 'OPMGRRMS1.xxx.xxx.xxx.xxx' in which the location monitoring object is contained is not available All services have been restarted successfully without error...

  • Server Refresh - Best Practice