Front end and console ports are down for switch WS-C3750X-48PF-S
We have a switch WS-C3750X-48PF-S in the stack and front end and console ports stopped working and are down.
I have tried to replug power cable but this didn't help, please let me know if I could replug stack power for this switch without outage of other switches in the stack, since switches are connected into the ring
Please let me know what might be the possible root cause
#sh switch stack-ports
Switch # Port 1 Port 2
2 Down Ok
3 Ok Ok
4 Ok Down
Hello,
There is a problem with the stacking connection between switch 4 and 2. Can you try replacing the stacking cable between these switches?
Similar Messages
-
Lotus notes as a front end and oracle as backend
Dear All,
Can i use lotus notes as a front end and oracle as backend atleast for few forms in my application.
If Yes how to go about it.
I have not tried it even once
Kindly also advice if this is appropriate forum to ask this question
Best Regards,
Devendra ShelkeDear All,
Context for asking above question :
We use Form 6i and Report 6i, Application Server 9i and 9i DB.
But for some forms we want the user to enter the data through Lotus Notes but get updated in 9i DB used by Form 6i.
Best Regards,
Devendra -
Lync 2013 Enterprise load balancing on the front end and edge pool
Hi,
I am setting up a Lync 2013 Enterprise deployment consisting of a Front End pool (x2 FE servers) and an Edge pool (x2 Edge servers). I'm seeing some conflicting advice regarding load balancing using hardware or DNS for the front end and the edge.
On the front end I have 2 internal DNS records 'lyncfepool1.contoso.local' each of which map to one of the IPs of the FE servers. I've used my details to populate the Detailed Design Planner excel spreadsheet and am told that I require a HLB to load
balance my front end pool. I'm aware of the need to load balance HTTPS traffic internally (which will be done by TMG) however other traffic to the front end (SIP, etc) can be balanced by DNS only, and not require a HLB?
Can someone clarify the front end requirement?
Also - looking now at the edge pool - this site again have two edge servers in a pool. We are using a total of six private IP addresses, two per edge service (2 x av.contoso.com, 2 x sip.contoso.com and 2 x webcon.contoso.com). These will be
NAT'ed by the external firewall and directed to the respective external (DMZ) IP addresses on the Edge servers on port 443. I know this isn't true roundrobin due to the intelligence of the Lync client when connecting (in that the Lync client will connect
to one of the public IPs and if it can't connect, it will know to connect to the other service IP), however I want to clarify this set up, particularly the need to direct the external public IP traffic at the DMZ Edge IP specified in the topology builder.
I've attached a basic diagram of the external/DMZ/Edge side which hopefully helps with this question
Persevere, Persevere, Per..That is because you will always need HLB for a front-end server since it hosts the Lync webservices which use HTTP/HTTPS traffic.
The description on the calculation tool also describes this correctly:
Supports Standard and Enterprise pools (up to 12 nodes), with pure device-based load balancing or a combination of DNS load balancing and device-based load balancing (for
Lync web services)
You can use either Hardware or DNS loadbalancing for SIP traffic only, but you will always need a HLB for the webservices. Both are applicable for the Front-End so you have either
full HLB for both SIP and HTTP(S) traffic
DNS LB for SIP traffic and HLB for HTTP(S) traffic
Hope this is more clear :-)
Lync Server MVP | MCITP Lync Server 2010 | If you think my post is the answer to your question, please mark it as answer so future visitors can easily find it. -
Https front end and http backend
Hi there....I am having a small issue....I have a web app that is https based....I have installed the cert on the CSS, and DNS for this app points to the VIP....the client is wanting to have an https front end, and then load balance in http to the backend servers....the issue I am running into is that this only works if I have an active port 80 rule on that same VIP....if I suspend the port 80 rule and only leave the port 443 rule active on that VIP, it doesn't work....please see appropriate config portions below....Thanks in advance!
Sandeep
ANy suggestions? I have been trying this for a couple of days now...it works fine if the backend sessions are also https, but the client has changed their requirement....
ssl-proxy-list SSL1
ssl-server 1
ssl-server 1 rsakey app1-test
ssl-server 1 rsacert app1-test
ssl-server 1 vip address 10.19.55.10
ssl-server 1 cipher rsa-with-rc4-128-md5 10.19.55.10 81
backend-server 1
backend-server 1 port 81
backend-server 1 server-ip 10.19.55.132
backend-server 1 ip address 10.19.55.132
backend-server 2
backend-server 2 port 81
backend-server 2 server-ip 10.19.55.133
backend-server 2 ip address 10.19.55.133
backend-server 3
backend-server 3 port 83
backend-server 3 server-ip 10.19.55.132
backend-server 3 ip address 10.19.55.132
backend-server 4
backend-server 4 port 83
backend-server 4 server-ip 10.19.55.133
backend-server 4 ip address 10.19.55.133
backend-server 5
backend-server 5 port 85
backend-server 5 server-ip 10.19.55.132
backend-server 5 ip address 10.19.55.132
backend-server 6
backend-server 6 port 85
backend-server 6 server-ip 10.19.55.133
backend-server 6 ip address 10.19.55.133
active
service webserver002:81
ip address 10.19.55.132
port 81
keepalive port 2199
keepalive type tcp
protocol tcp
active
service webserver003:81
ip address 10.19.55.133
port 81
keepalive port 2199
keepalive type tcp
protocol tcp
add ssl-proxy-list SSL1
active
service webserver002:83
ip address 10.19.55.132
port 83
add ssl-proxy-list SSL1
keepalive port 2399
keepalive type tcp
protocol tcp
active
service webserver003:83
ip address 10.19.55.133
port 83
keepalive port 2399
keepalive type tcp
protocol tcp
add ssl-proxy-list SSL1
active
service webserver002:85
ip address 10.19.55.132
port 85
add ssl-proxy-list SSL1
keepalive port 2599
keepalive type tcp
protocol tcp
active
service webserver003:85
ip address 10.19.55.133
port 85
keepalive port 2599
keepalive type tcp
protocol tcp
add ssl-proxy-list SSL1
active
service SSL_Front
slot 2
type ssl-accel
keepalive type none
add ssl-proxy-list SSL1
active
owner app1-test
content app-test_back
vip address 10.19.55.10
add service webserver002:81
add service webserver003:81
add service webserver002:83
add service webserver003:83
add service webserver002:85
add service webserver003:85
balance aca
protocol tcp
port 81
active
content app1-test_front
vip address 10.19.55.10
application ssl
add service SSL_Front
protocol tcp
port 443
advanced-balance ssl
balance aca
activeThanks for the quick reply....there is another port 80 rule setup for that vip....I was using that to test with the app until I got the front end https rules working....
my port 80 rules just says listen to 10.19.55.10 on port 80 and load balance btwn the webervers on port 8x in the back end...
I am trying to do https front end and http backend....
no where in my SSL config have I configured port 80....but when I suspend that rule it all fails....
I am wondering if the backend server sessions are happening properly?
I don't fully get what you mean by "You need to have the rule in port 443 to match traffic coming from the client and the clear text rule (port 81) to match traffic already decrypted coming from the SSL module"
Haven'tI done that?
Thanks again!
Sandeep -
Configuring Lync 2010 Mobility with Front end and Edge Server
I have been racking my brain the past week trying to figure out how to get the lync edge server working properly and how to get the mobility service working properly.
Currently I have 1 front end server that is configured and working. I have one edge server that has been configured according to nearly every online help I could find along with public CERT.
If I use microsoft's online connectivity test and I run the test for
Lync Server Remote Connectivity Test everything passes. I am also able to connect to lync using a windows lync client from outside of the internal network however I have to specify the server name as being sip.ourdomain.com I cannot get connected using
autodiscover.
When I run the Lync Autodiscover Web Service Remote Connectivity Test it fails due to SSL error to lyncdiscover.ourdomain.com which then lead me down the path that I needed to install
the Mobility service but it also tells me that I may need to update our SSL cert as well.
This is where I am getting confused and would like to be pointed in the correct direction.
When I installed mobility service on the front end server it created the autodiscover section in IIS. If I am inside our network I can browse to it without any issue. Where I am confused at this point is how to either setup DNS or how to configure
the edge server to use autodiscover.
Do I need to setup an additional public IP and point lyncdiscover.ourdomain.com to the IP of our front end server or to our edge server? If I have to point this to our front end server then that would mean that I use one public IP that goes to 443,
444 and 5061 for our edge server and then I would need one public IP that goes to ports 443 and 80 that get redirected to ports 4443 and 8080 on our front end server? If that is the case then do I have to get an external cert for the front end server
that contains lyncdiscover or can clients connect if it is just using the self signed cert from the domain?
This is where I am getting confused at and hopefully some nice folks out there can clarify this for me so I can get this resolved.
Thank you
KKYou need an additional public IP to point to a reverse proxy, which will listen on port 443 and proxy requests to your front end server on port 4443 (notice the extra 4). You can use IIS ARR, Web Application Proxy, or whatever else you may have for
this purpose, but you need to ensure you redirect port 443 to port 4443. This reverse proxy cannot be collocated on your front end server or edge, you'll need a separate box or appliance.
Beyond Lyncdiscover, you'll want to do this for your external web services FQDN as defined in the topology builder and your meet and dialin URLs too. You'll want a third part cert for all of this (though it doesn't need to be installed on the front
end, just the reverse proxy) so that you don't need to install any internally signed root certs on anyone's smartphone.
Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question please click "Mark As Answer".
SWC Unified Communications
This forum post is based upon my personal experience and does not necessarily reflect the opinion or view of Microsoft, its employees, or other MVPs. -
Authentication with UME separation of front end and back end
My webdynpro project has 2 application. One for Admin one for Rating.
Is it possible to create a java class at Webdynpro level and share it between the 2 applications?
Why the need?
Created a custom class (lets called it CommonEJB), to point to the right pages and set of UI controls after the initial login with UME. This class utilizes the IWDClientUser.getSAPUset() method to get IUser object.
If it is not possible to create a java class at Webdynpro, then this ejb will need to be deployed to the backend.
Putting it at the backend is not good as security wise, its always better to separate the authentication between front and back end.
Any ideas/solutions?
thankss0003358504
au-?Krup
LDAP
==============================================
Computer Associates Int'l [eTrust Directory]
Critical Path [CP Directory Server (CP DS)]
Microsoft [Windows 2000 Active Directory Server]
Microsoft [Windows 2003 Server - Active Directory]
Netscape Communications [Netscape Directory Server]
Novell [DirXML Driver for User Management]
Novell [Novell DirXML Driver for SAP HR/PA]
Novell [Novell eDirectory]
Oracle Deutschland [Oracle Internet Directory (OID)]
Siemens [DirX Directory Server]
Siemens [DirX Extranet Edition]
Sun Microsystems [Sun Java System Directory Server]
Test Objectives
Testing Scope
Test Approach
Test Environment
Test Data
Entry / Exit Criteria
Risks
Schedule and Resources
SIT Deliverables
Test Planning Source Documents
Well, i wish to create a java class that can separate the view areas depending on their login.
lets say you're a manager, u can see certain views. and if you're a supervisor u see another. This is achieved using the java class with information from getSAPUser() position. After retrieving the position, using the java class will programmatically assigned the appropriate views, buttons, tabs etc.
so this class need to in front end, and not back end. problem is we have 2 application.
if the class is created front end in one application can it be shared with another. -
Connecting to SQl server ( MS acess front end) and pull the data into BI
Dear all,
i need to extract the data from SQl server ( MS acess front end) and pull the data into BI .
i need to know what are the steps need to follow on this..
can any one help me on this...!
Thanks,
SivaHi,
1. login to sql server u2013 with ur server credentials and connect.
2. select ur sql for ex: sap bw
3. Right click u2013 sapbw - task - export data From sql to excel I m exporting So give sql details
4. Destination u2013 select excel.. and browse where u want to save the fileu2026
5. give next
6. select from which table u want to export
7. click on next
8. click on finish
9. close
10. go to desktop and open the xyz.xls file
11. not make it as csv file and load the data to BI as a flat file
Hope it will help you.
Regards, -
Advice regarding using 3.5 front end AND 7.0 front end on users' machines
Hello everyone,
We are trying to determine the best way to roll out the new 7.0 front end tools. We are doing a technical upgrade to 2004s first, and later converting all the objects. Initially we plan to have both the 3.5 and 7.0 front end tools both residing on users' pcs, until we convert all objects to 04s.
Does anyone have a recommendation for rolling out the new tools to users, with out the risk of having them accidentally convert objects when they open queries (we have been told that if you open a query in the new tools, it automatically converts the objects). We need to prevent this from happening until we are ready to convert all the objects.
Thanks in advance for any advice!The most important thing is to use naming conventions (maybe a new naming convention using the new tools). Then set security up to prevent conversion depending on your scenarios. When migrating, it is recommended to be very careful around converting global elements (variables, Global Calculated Key Figures, and Global Restricted Key Figures). Within the RSZCOMPDIR table, there is a version field (greater than 100 is 2004s elements) so you can see the version there as well. It is recommended to migrate all queries within a single infoprovider together to avoid conflicts with global elements.
-
Removing admin password form Access 2003 database front end and back end
We have a legacy database that has been passed down from the original creator, who is no longer with the organization. It was created in Access 2003. It has a front end and a back end. The original admin password can not be located and we are in the process
of upgrading this application to 2010. Is there a way to remove that password so we can make changes to the original files?Hi,
What password are you talking about, the one created with the workgroup manager? That will be difficult since 2010 doesn't have the workgroup manager anymore. You can still use the database in the 2010 environment but you can't make any changes to the original
database without the password.
Maurice -
Why the Fibre uplink ports are down state even after giving no shutdown command at the interface
Hi
My Predecessors brought 2 CISCO 3750 switches and implemented LACP on these core switches. Due to looping in the network the Fibre uplink ports GigabitEthernet1/1/3 and GigabitEthernet2/1/3 are down (I think these uplink ports are mirrored in the LACP concept)
Please see below from the configuration.
I logged into the core switch and went to this particular interface GigabitEthernet1/1/3 and I gave the following command and still the port is in the down state after I gave no shutdown command. Do I need to give the same no shutdown command at interface GigabitEthernet2/1/3 as well ?
Switch-Core1(config) interface GigabitEthernet1/1/3
Switch-Core1(config-if)#no shutdown
Switch-Core1(config-if)#
Please see below After no shutdown command given still these 2 Gigabit fibre uplink ports are down.
GigabitEthernet1/0/20 unassigned YES unset up up
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset up up
GigabitEthernet1/1/1 unassigned YES unset up up
GigabitEthernet1/1/2 unassigned YES unset up up
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset up up
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
GigabitEthernet2/0/1 unassigned YES unset up up
GigabitEthernet2/0/2 unassigned YES unset up up
GigabitEthernet2/0/3 unassigned YES unset up up
GigabitEthernet2/0/4 unassigned YES unset down down
GigabitEthernet2/0/5 unassigned YES unset up up
GigabitEthernet2/0/6 unassigned YES unset down down
GigabitEthernet2/0/7 unassigned YES unset down down
GigabitEthernet2/0/8 unassigned YES unset up up
GigabitEthernet2/0/9 unassigned YES unset up up
GigabitEthernet2/0/10 unassigned YES unset down down
GigabitEthernet2/0/11 unassigned YES unset down down
GigabitEthernet2/0/12 unassigned YES unset down down
GigabitEthernet2/0/13 unassigned YES unset down down
GigabitEthernet2/0/14 unassigned YES unset up up
GigabitEthernet2/0/15 unassigned YES unset up up
GigabitEthernet2/0/16 unassigned YES unset up up
GigabitEthernet2/0/17 unassigned YES unset up up
GigabitEthernet2/0/18 unassigned YES unset up up
GigabitEthernet2/0/19 unassigned YES unset down down
GigabitEthernet2/0/20 unassigned YES unset up up
GigabitEthernet2/0/21 unassigned YES unset down down
GigabitEthernet2/0/22 unassigned YES unset up up
GigabitEthernet2/0/23 unassigned YES unset down down
GigabitEthernet2/0/24 unassigned YES unset up up
GigabitEthernet2/1/1 unassigned YES unset up up
GigabitEthernet2/1/2 unassigned YES unset up up
GigabitEthernet2/1/3 unassigned YES unset down down
GigabitEthernet2/1/4 unassigned YES unset up up
Te2/1/1 unassigned YES unset down down
Te2/1/2 unassigned YES unset down down
Port-channel1 unassigned YES unset down down
Port-channel2 unassigned YES unset down down
Please let me know if I am doing something wrong .Please post me some tutorial to sort this.It is possible you are overloading that little 4215. If that is the case you should also be seeing "missed packet percentage" messages in your events.
How much traffic is your 4215 getting? Those sensors will start to drop packets for inspection at about 30 Mb/s.
- Bob -
What is BW Front-end and Whats BW Back-end? Technica ? Functional?
Hi Gurus,
Can some one throw light on the diff between a BW Front-end and BW BAck-end? How will u diff the responsibilities of a Functional BW Consultant and Technical BW Consultant?
thanks
kishore karnatiHi,
BW Front end is the one that deals with reporting. Eg: BEx
BW back end is the one that deals with the components that stores data which is used for the reporting purpose.
Eg: R3
Functional consultant comes into picture when there is a need to understand the functional aspects of a requirement, say for example, you have a requirement to use Sales Order in your BW application, as a pure BW person, you wont know what a Sales Order is about. A functional consultant has the ability here to map the sales order requirement in the BW application. This means that, he knows what field and what table this sales order relates to. This way, a functional consultant maps the user requirements to the technical detail in the system.
A pure BW consultant is one who knows how to setup data extraction from source system , how to build various components in a BW system, how to schedule a load, how to troubleshoot in case of any issues in the BW application.
Hope this helps..
Assign points if this helps...
Thanks,
Raj -
Lync Front End and Edge on same host
Hey guys can anyone confirm if having a front end and edge on single host is supported, providing of course the ram and cpu requirements are met.
Thank you.The Front End and Edge must be on separate computers and can't be collocated. Both servers can coexist on the same Virtual Host if using VMware or Hyper-V.
See: http://technet.microsoft.com/en-us/library/gg398131.aspx
Please mark posts as answers/helpful if it answers your question.
Blog
Lync Validator - Used to assist in the validation and documentation of Lync Server 2013. -
Access to serial and ethernet port in FPGA for cRIO-9068
hi
i want to know if i can Access to serial and ethernet port in FPGA for cRIO-9068 like camera IP
thanks for helpdalyto wrote:
thanks
but how i can i acquire image with IP camera and fpga ???
The Ethernet hardware interface in the cRIO is not directly connected to the FPGA backplane in a way that you could directly access it. Even if you could it would be a pretty bad idea to try to do. A fully operational TCP/IP network stack implementation in the FPGA would not leave much resources for anything else even on the biggest FPGAs available. That doesn't include support for the typical image compression algorithmes which are even more complicated to implement on FPGA. Even if you would go to highly optimized VHDL code directly it would be a pretty difficult thing to do!
In fact implemenintg the MAC and PHY of an ethernet interface on the FPGA is totally trivial in comparison. The IP level could also be implemented fairly easily in the FPGA but anything above that is going to give you bad headaches and still will be very limited in number of connections and packet sizes it can support.
Rolf Kalbermatter
CIT Engineering Netherlands
a division of Test & Measurement Solutions -
Jwsc Error - Only HTTP ports are supported for JAX-WS
Hi
I am trying to create a Webservice from wsdl. I have been able to generate java files and jar file with wsdlc ant task.
However when i try jwsc I get follwoing error
[jwsc] [ERROR] - Only HTTP ports are supported for JAX-WS.
<----- follwowing task for generating java files --->
<taskdef name="wsdlc" classname="weblogic.wsee.tools.anttasks.WsdlcTask"/>
<target name="generate-from-wsdl">
<wsdlc
srcWsdl="wsdl_files/UserPrefWebService.wsdl"
destJwsDir="web/web-inf/lib"
destImplDir="src"
packageName="com.ws.userpref"
type="JAXWS"/>
</target>
<----- follwowing task for generating class files ----THIS IS FAILING --->
<taskdef name="jwsc" classname="weblogic.wsee.tools.anttasks.JwscTask" />
<target name="build-service">
<jwsc srcdir="src" destdir="ear">
<jws file="com/ws/userpref/UserPrefWebServiceImpl.java"
compiledWsdl="web/web-inf/lib/UserPrefWebService_wsdl.jar"
type="JAXWS"/>
</jwsc>
</target>
<----- This is the Error --->
C:\Development\CFCDemoWorkspace\UserPreferencesServer>ant build-service
Buildfile: build.xml
build-service:
[jwsc] JWS: processing module /com/ws/userpref/UserPrefWebServiceImpl
[jwsc] Parsing source files
[jwsc] Parsing source files
[jwsc] 1 JWS files being processed for module /com/ws/userpref/UserPrefWebS
erviceImpl
[jwsc] C:\Development\CFCDemoWorkspace\UserPreferencesServer\src\com\ws\use
rpref\UserPrefWebServiceImpl.java 18:8
[jwsc] [ERROR] - Only HTTP ports are supported for JAX-WS.
[AntUtil.deleteDir] Deleting directory C:\DOCUME~1\138904\LOCALS~1\Temp\_3os716
BUILD FAILED
C:\Development\CFCDemoWorkspace\UserPreferencesServer\build.xml:24: weblogic.wse
e.tools.WsBuildException: JWS Validation failed.
Total time: 10 seconds
Does any one has any input on this error?
Thanks
SrikantThanks David,
Below is the wsdl
<s0:message name="ws_getUserPreference">
<s0:part element="s1:ws_getUserPreference" name="parameters"/>
</s0:message>
<s0:message name="ws_getUserPreferenceResponse">
<s0:part element="s1:ws_getUserPreferenceResponse" name="parameters"/>
</s0:message>
<s0:portType name="UserPrefWebServicePort">
<s0:operation name="ws_getUserPreference" parameterOrder="parameters">
<s0:input message="s1:ws_getUserPreference"/>
<s0:output message="s1:ws_getUserPreferenceResponse"/>
</s0:operation>
</s0:portType>
<s0:binding name="UserPrefWebServiceSoapBinding" type="s1:UserPrefWebServicePort">
<s2:binding style="document" transport="http://schemas.xmlsoap.org/soap/http"/>
<s0:operation name="ws_getUserPreference">
<s2:operation soapAction="" style="document"/>
<s0:input>
<s2:body parts="parameters" use="literal"/>
</s0:input>
<s0:output>
<s2:body parts="parameters" use="literal"/>
</s0:output>
</s0:operation>
</s0:binding>
<s0:service name="UserPrefWebService">
<s0:port binding="s1:UserPrefWebServiceSoapBinding" name="UserPrefWebServicePortSoapPort">
<s2:address location="https://localhost:7001/UserPrefService/UserPref"/>
</s0:port>
</s0:service>
</s0:definitions>
do i need to add <wlhttptransport/> in jws during the buid? -
What is this email alert: TUI-AD: All AD agents are down for realm Windows?
I added our IT group e-mail to the Ironport S160 to be alerted when product keys are about to expire. Our IronPort C160 e-mail filter does this but the S160 did not.
We periodically get this email:
Subject: Critical <System> webfilter.domain.com: TUI-AD: All AD agents are down for realm Windows
The Critical message is:
TUI-AD: All AD agents are down for realm Windows
Product: Cisco IronPort S160 Web Security Appliance
Model: S160
Version: 7.5.1-079
Serial Number: (removed for public posting)
Timestamp: 24 Mar 2014 07:20:27 -0400
Any idea what this means? Everything is working normally. How can I stop this message?Upon further investigation in services.msc on that server I see a Cisco AD Agent. I did some digging on this service and its located in C:\IBF.
First why is it called IBF?
Second, whats in here is this:
\adObserver
\CLI
\radiusServer
\watchdog
AD_Agent.Uninstaller.exe
AD_Agent-version-1.0.0.32.1-build.598.IBF
The emails came in at these times
3/24 11:59 PM
3/24 7:20 AM
3/23 12:59 AM
3/23 12:06 AM
3/22 10:56 PM
3/22 1:20 AM
3/21 12:52 PM
3/20 10:51 PM
Maybe you are looking for
-
How to use $PROFILES$CONC_COPIES in plsql
Can you give me an example of using $PROFILES$.CONC_COPIES in plsql? I need to change a plsql program to product 2 set of output reports each time when the job is run. User doesn't to change user profile option number of Concurrent copies. Thanks.
-
I just paid full price for PS. 6. I have far to many questions . where do I get a manual?
-
Will my iMac that I bought in America will work in Europe ( my Mac Originally released October 2012 it is the 27-inch iMac 3.2GHz quad-core Intel Core i5). How can I tell if I can plug it to 220v ?
-
Hey, I have been looking at some samples of the Accordion and the ones you have all show a really nice smooth sliding transition. It seems to speed up the slide at the start from 0(mph??) to the actual speed and then easing it back down to 0 again as
-
IPhoto unbearably slow!!
iPhoto takes ages to load up, when scrolling it will hiccup every, say, 20 photos, opening photo will take a few seconds, and every time I close it, not only does it take 30 seconds to close, but then it'll freeze up my computer for like 10 minutes w