Full load to Delta load for 0ASSET_AFAB_Text load

Hi Experts,
Standard extractor is not enabled to change the mode to Delta.
Is it possible to change the Standard Extrator from Full to Delta. if so how we can do it?? Full load it taking long time so want to change the process to delta.
Please suggest me any other options too......
Thanks in advance,
rCm.
No Luck
Edited by: rCm on Jan 29, 2010 2:10 PM

Hi,
0ASSET_AFAB_TEXT Datasource will fetch the Data based on the Function Module ARBW_BIW_GET_MASTER_DATA
SAP has not provided the Delta Functionality for this Datasource,
check the Roosource and Rodeltam tables for more clarity
Regards
Reddy A

Similar Messages

  • HP Load Runner: CPU usage for this load generator has exceeded 80%

    Recently I have downloaded LR 12.1 and installed.   Observed error  CPU usage for this load generator has exceeded 80% when executing the test with 5 user load using AJAX Trulcient IE script. For each virtual user in the script one TcWebIELauncher.exe hads been initiated and running during the test execution. Each TcWebIELauncher.exe instance is taking min 14% CPU utilization and CPU utilization for 5 users is around 75% at the time of test execution.  What is the reason behind this high CPU utilization for this less user load?. Please suggest how to handle and fix the issue.
    regards,
    Sreekanth

    You can download Trail version of Loadrunner from HP site.  That's true. all HP testing tools products are license based.
    i) If you want to use for SAP applications, you need to have SAP protocals (SAP GUI and SAP WEB). So how this licenses works is, if you want to buy 50 Vusers for SAP it cost you around $ 32k and it depends on company discount. so you need to work with HP Sales team to get the quotation then based on no of Vusers and you can procure it.
    ii) As for as i know, there is no  HP LR integration with Solution Manager.
    let me know if you have any questions.

  • Full vs. Delta Load

    Hi BI-Experts!
    This is a rather general question.
    Is there a recommendation when to use Full or Delta Load?
    I know the functional differences but do SAP or some technical reasons say that each of them may only be used in special cases?
    For example Delta Load can only be used with SAP source systems?
    Best regards,
    Philipp

    Hi Philipp,
    This is a pretty open-ended question.  I will give you a few examples of when I use each ....
    Delta's:
    1.) If the record set is large and changes a lot daily.  If you have a large initial load, let's say 2Million records and you get about 200k records per month, then you want to use a delta mechanism. There are just too many records to reload daily. 
    2.) If the record set is wide (many fields instead of a few), it will take less load time to run a delta than a full load.
    3.) Datasource restrictions....some business content datasources don't have full loads and vice versa (some don't have deltas).
    4.) Do my loads take too long?  If so, I will convert full loads to delta's to shave off time here and there.
    Full
    1.) I gauge this mainly based on load time.  If it takes 5 minutes to load 100k records, then it's going to take longer to figure out what delta's were missed (if there was a problem) than it would to just reload the dataset.
    2.) Do my requirements dictate that I need to drop and reload the dataset?  The best example of this would be the current year's forecast.  Some companies revise the forecast and don't want to keep any previous revisions.
    3.) Some data loads load a snapshot of a specific date.  So, if I wanted to take a snapshot of inventory in a DSO/ODS on Monday, I would Datamart it into a Cube doing a full load for Monday's date.
    Hope it helps!
    Thanks,
    Brian

  • I am running full upload daily now i want to load delta records how can i

    Hi Gurus,
      I am running full upload daily now i want to load delta records how can i do that could any body help recording this..
    Regards
    Kiran Kumar

    Hello Kiran,
    First make sure that you datasource is delta enabled. If so create a new infopackage for Init without data transfer and execute it. Then create a InfoPackage for Delta.
    Thanks
    Chandran

  • Master data Full load to Delta load

    HI
    I have Order number (ZONDRNO)for this we are loading the Master data form BW  to BW full load.
    This Order number is Generi Data source
    Can any one help me how to do master data Full load to Delta load.
    Thanks in Advance
    kumar
    Edited by: kumar reddy on Oct 9, 2008 3:14 AM

    Hi,
    Firstly you are stating that you are loading from BW to BW. How are you doing it ? Are you doing through a datamart ?
    Secondly you have also told that you have created a generic datasource so from this we can deduce that you are not doing a datamart load but you are doing through a datasource.
    Thirdly to achieve delta for a generic datasource you should make sure that the datasource in question here is delta enabled.
    Once all these are done all you need to do is a delta init and schedule further delta loads.
    Regards,
    Pramod

  • Can I use full load for daily loads in LO Cockpit extraction.

    I am using LO cockpit extraction for 2LIS_11_VAITM and i am using delta load for daily load and I have following doubt.
    Can i use full load for daily loads instead of delta in LO Cockpit extraction.
    Because, my understanding is that full load always takes data from setup tables in ECC and set up tables will not have delta data.
    pls reply. Thanks.

    You are right abt the understanding that full load (atleast for the extractor at hand) brings data from setup tables. You are also right that delta records are not loaded into setup tables.
    So if you plan to do full loads every day, you have to load the setup tables everyday. It is at this juncture that I have to remind you that, filling of setup tables requires a downtime of the system to ensure  that no changes / creates happen during the process.
    Hence performing a full load is not a very good approach to go by...especially when SAP made the job easy by doing all the dirty work of identifying changes and writing them to extraction queue.
    Hope this helps!

  • Need to load only delta where I receive full initial file all the time

    Hi All,
    Can any one let me know is there any feature in DS where we can load only delta/updated/changed fileds from the flat file (which is full load)...
    Scenario is : system will send all the time full initial load in a flat file format where DS need to load initially all the records later it has to update only the delta changes... So wondering do I need to perform full load in DS all the time or is there any feature to load initially full file and load only updates moving forward?
    Thanks
    Rajeev

    If you are indeed getting a full dump of the entire target table from the source system, every time, you may find it faster to truncate-and-reload your target table, depending on what else (if anything) goes in there, the number and nature of transformations, etc. Running a really large set of records through a Table Comparison transform, comparing on all fields (which it sounds like you'd need to do), can take a while, and given that you've always got "all the records," may be beside the point.
    You also may want to investigate the use of checksum fields. It's possible that adding (and, of course, calculating) checksum fields on each row in both the source and target and then comparing those to identify updates would be faster than doing a Table Comparison transform-based comparison of each field, for each record.
    Best wishes,
    Jeff Prenevost

  • Change load full data to Delta

    Hi!!
    In the past, we load Full data for a customized DataSourece. Now I changed the DataSource to load delta datas.
    This data source was connected a ODS and when I tried to initialize delta process I received the error message. "Full updates already available in ODS 0SAL_DS01 ; Cannot update init./delta".
    Someone know, How can I Initialize Delta Process?
    Regards,
    Cesar G. Batista

    Hi.............
    ODS does'nt support Full upload and delta upload parallely..........suppose a ODS is getting loaded with delta upload...........then if u do a full upload.........then ODS activation will with this error...........then u have to convert full upload to full repair...........
    Go to SE38 >> Program : RSSM_SET_REPAIR_FULL_FLAG...................this program also exists in 3.5.............check it properly............
    Check SAP note 689964 ........
    Hope this helps........
    Regards,
    Debjani.........

  • Full load to Delta conversion of standard extractor

    Hi Gurus,
    Data have been loaded to Infocube from standard extractor( LO LIS) as a full load.Now I needs to convert full load to delta.Kindky throw your ideas, what are the points I have to be considered .
    Thanks
    Siva

    HI,
    For getting the Delta u have to first Initlize the Cube. the option is available at InfoPackage level.
    After that only u can get the Delta.
    that is only the Way.
    Assign Point if it helps.
    Regards,
    sandeep

  • BI7 : Change full load to delta load - things to do?

    http://wiki.sdn.sap.com/wiki/display/profile/2007/04/30/Differencebetweenfull,intialanddeltaupdatemodes
    Difference: Full load, Delta Load & INIT load in BW
    Hi.
    Since am not familiar with BW request clarity as to how to achieve the following :
    We are on BI 7.
    On our BW server, One of the Existing process chain loads data as full load daily Till date.
    This schedule runs for about 4 to 6 hours during the nights. And the data seems to be growing.
    And doing full load, now seems, not that meaningful for data analysis.
    So we now feel we need not do a full load every day. But do only the incremental load.
    How to make this effective in our existing process chains.
    I went thro the 2 links above, but a few things am not clear.
    What exactly needs to be done to change a full load into a delta load.
    Also do not wish to have any data loss happening.
    We run the schedules on a particular process chain for BW around 1 am.
    Say from tomorrow I want to have the data loading as delta.
    What exactly are the steps to be followed.
    Precautions to be taken
    So that we have the correct data load and no data is lost - while doing this.
    Things to do am not clear :
    do initialization with data transfer / or without data tranfer ?
    The make it delta?
    So that from tomorrow all data loading becomes delta ?
    Or
    since in our scenario,
    daily basis it is full load.
    Just make it delta load,
    so that whatever changes will run in the next days schedule.
    What all things are to be done stepwise.
    if anyone could advise.
    That would be very helpful.
    Also any documentation which explains all these if someone could share the link please ?
    Many thanks
    indu
    Edited by: Indumathy Narayanan on Aug 26, 2011 5:50 PM

    Hi,
    Kindly look at following links as well
    http://help.sap.com/saphelp_nw04s/helpdata/en/44/9821620553053de10000000a1553f6/content.htm
    Generic Delta
    If a field exists in the extract structure of a DataSource that contains values which increase monotonously over time, you can define delta capability for this DataSource. If such a delta-relevant field exists in the extract structure, such as a timestamp, the system determines the data volume transferred in the delta method by comparing the maximum value transferred with the last load with the amount of data that has since entered the system.  Only the data that has newly arrived is transferred.
    To get the delta, generic delta management translates the update mode into a selection criterion. The selection of the request is enhanced with an interval for the delta-relevant field. The lower limit of the interval is known from the previous extraction. The upper limit is taken from the current value, such as the timestamp or the time of extraction. You can use security intervals to ensure that all data is taken into consideration in the extractions. After the data request was transferred to the extractor, and the data was extracted, the extractor then informs generic delta management that the pointer can be set to the upper limit of the previously returned interval.
    The delta for generic DataSources cannot be used with a BW system release prior to 3.0. In older SAP BW releases, the system does not replicate DataSources for master data and texts that were made delta-enabled using the delta for generic DataSources.
    Determining the Generic Delta for a DataSource
           1.      Choose Generic Delta.
           2.      In the subsequent dialog box, specify the delta-determining field and the type for this field.
           3.      Maintain the settings for the generic delta:
                                a.      Specify a security interval.
    The purpose of a security interval is to make the system take into consideration records that appear during the extraction process but which remain unextracted (since they have yet to be saved) during the next extraction.
    You have the option of adding a security interval to the upper limit/lower limit of the interval.
    A security interval should only be specified for the lower limit when the delta method results in a new status for changed records, in other words, when the status is overwritten in BW. In this case, duplicate data records that could arise in such a safety interval have no affect on BW.
                                b.      Choose the delta type for the data to be extracted.
    The delta type is used to determine how extracted data is interpreted in BW and which data targets in which it can be posted.
    With the delta type additive delta, the record to be loaded for summarizable key figures only returns the change to the key figure. The extracted data is added in BW. DataSources with this delta type can supply both ODS objects and InfoCubes with data.
    With the delta type New Status for Changed Records, every record to be loaded returns the new status for all key figures and characteristics. The values are overwritten in BW. DataSources with this delta type can write the data into ODS objects and master data tables.
           4.      Save your entries.
    Delta transfer is now possible for this DataSource.
    After generating the DataSource, you can see this from the marking for the field Delta Update on the DataSource: Customer Version screen.
    In systems from release 4.0B, you can display the current value of the delta-relevant field in the delta queue.
    Thanks and regards

  • Full Load and delta loads of HR Data using ABAP Program

    Hi All,
    I need to write an ABAP program that will pull some HR data from some of the infotypes.When i run it for the first time it should pull all the data for all the employees but in the subsequent runs it should run only the delta changes
    for example
    inital run is on 04/30 it should pull all the data for all the employees
    next run 05/02 then it should pull onlly the infotypes for which there is a change between 04/30 and 05/02
    Please let me know the solution
    Thanks
    Bala Duvvuri

    Rob,
    I understand that I need to AEDTM field but the problem is
    during the initial load i will not have any control date stored in the z table so i will fetch all the records using the select queries on various infotypesin the if condition but the problem is i need to repeat the same queries by adding the AEDTM condition in the else condition where control date is not initial(not an initial load) so it will be a duplicacy of all the select queries.
    is it a good programming style?please let me know your thoughts on this
    if p_ctrl is initial " Initial load
    select queries
    else " subsequent runs
    same select queires with AEDTM condition
    endif.
    Thanks
    Bala Duvvuri

  • Change from Full load to delta load.

    Hi Gurus,
    I have one ODS object which is extracting data from r/3 system.this ODS object is getting loaded on a daily basis,& it's having heavy volume data (takes almost 8 hours to load).
    Now I want to change the load mode of that ODS from FULL load to Delta Load
    How can I do that ?
    I tried to do* Init without data transfer* from source to this ODS obejct , but while activation it's saying Full load is already loaded so no init
    I want to change the load mode of that ODS object without deleting the data,as it takes lot of time to load the total data.
    Is there any way to that??
    Plz help.Thanks in advance.
    Regards,
    Kironmoy Banerjee.

    RSSM_SET_REPAIR_FULL_FLAG.
    1 more question,if run that function module,will it change the existing loads in Repair full mode?
    or it will load the total data again.
    If you run RSSM_SET_REPAIR_FULL_FLAG Program and give ODS name etc.. it will turn all Full loads to Repair full mode.
    Steps:
    1. Run that function module.
    Run Program RSSM_SET_REPAIR_FULL_FLAG
    2. give ODS,data source name.
    Yes
    3 it will change the existing load to repair full load,
    Yes
    4.Init without data transfer. (i am not sure if this step is required or not.)
    Yes
    5.delta load.
    Yes
    Thanks
    Reddy

  • Change the Full load to Delta load

    Hi All,
    I am loading the data form R/3 to BW with full load by using the generic data sources.
    Now I need to change the full load to delta. But I get the data 2 views and one FM.
    Some what I have got the solution, that is going RSO2 there generic delta will be available
    If I click I will get the one wind there 3 deltas form there I took time stamp. Then I need
    Select the field name.
    1) Now only my problem started in that field name there is no creation
    Date and last changed data, based on this we need to get the data from R/3 to BW.
    2) In that 3 datasorce I used the one DS function module in this also that field name is not
    available .
    3) In safety interval what I need to give.
    After doing all the changes in R/3 side wht are the change i need to in BW
    Please help on above 3 issues.
    Thanks
    Edited by: kumar reddy on Oct 19, 2008 4:09 AM

    Hi,
    1.) based on these fields you will get delta records from r/3 to BW.
    3.) safety interval :more clearly--- lower limit corresponds to last extraction
    time and upper limit specifies to the current extraction time. This is regarding the date .
    Check :
    how to generic delta
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/84bf4d68-0601-0010-13b5-b062adbb3e33
    SAFETY DELTA :
    check these links
    oss note 368739.
    Generic delta safty intervals
    oss note 392876
    safety interval
    0FI_GL_4 Safety Delta
    Genric delta from table  :
    check this thread which already discussed about this topic
    Generic Extractor - Delta
    Re: Generic delta Saftey interval.
    Hope this helps,
    Regards,
    Supriya

  • Data is not getting loaded using the Demon for RDA

    Hi friends,
    We are doing a POC for Real Time Data acuisition.
    For this we have copied an exisiting datasource and made it Real Time enabled.
    Replicated the datasource now we can see the new datasource in BW.
    We have created an Init Info Package (This loads only till the PSA).
    Loaded the data using Full DTP to load from PSA to the DSO, this succesfully loaded the data in the DSO.
    After that we Created a Delta Info package and a Delta DTP and assigned them to a Demon and started the demon. But strangely i can see the delta data getting Loaded to the PSA but there is nothing happening on the DTP. When i check the DSO manage there is no Delta request. The only request what we have is the Full load.
    Is there any step or something im missing? please guide me.
    Regards
    BN

    Hi,
    Deactivate the aggregates and then load the data from PSA to Cube.
    And then reactivate the aggregates. While reactivating them you can ask to fill them also.
    Regards,
    Anil Kumar Sharma. P

  • Delta records are not loading from DSO to info cube

    My query is about delta loading from DSO to info cube. (Filter used in selection)
    Delta records are not loading from DSO to Info cube. I have tried all options available in DTP but no luck.
    Selected "Change log" and "Get one request only" and run the DTP, but 0 records got updated in info cube
    Selected "Change log" and "Get all new data request by request", but again 0 records got updated
    Selected "Change log" and "Only get the delta once", in that case all delta records loaded to info cube as it was in DSO and  gave error message "Lock Table Overflow" .
    When I run full load using same filter, data is loading from DSO to info cube.
    Can anyone please help me on this to get delta records from DSO to info cube?
    Thanks,
    Shamma

    Data is loading in case of full load with the same filter, so I don't think filter is an issue.
    When I follow below sequence, I get lock table overflow error;
    1. Full load with active table with or without archive
    2. Then with the same setting if I run init, the final status remains yellow and when I change the status to green manually, it gives lock table overflow error.
    When I chnage the settings of DTP to init run;
    1. Select change log and get only one request, and run the init, It is successfully completed with green status
    2. But when I run the same DTP for delta records, it does not load any data.
    Please help me to resolve this issue.

Maybe you are looking for

  • No sound from apple tv when using airplay

    Hey, So here my problem, when I use airplay from my MBP(or iPhone)to my ATV2 audio will dropout. The song stil plays in iTunes(I can tell by the minute count) but no audio comes through my ATV2. Im using an ATT Uverse Cisco router, and all software i

  • Qty sales & month

    Dear Forums, If i want to get this report for This month so far ; item code, item description, DocDate,stock on hand, Qty sales, Turn over, Turn over days eg . April 20, 542514 / MILK/ 11-05-09 / 40 / 10 / 2.66666 / 80 / 20 / 30 542518/ SOAP/ 11-05-0

  • IPhoto doesn't Sync

    Hey everyone... when I dock my iPhone all of my assets in iTunes show up except for iPhoto. Aperture, movies, etc. all will sync but iPhoto doesn't show any of my albums. One post suggests that I remove all my keywords but, frankly, that isn't a solu

  • TS3217 This song skipping bug on iPods has been around for years!  Is there any solution yet?

    I've tried resetting my iPods.  (I've got 3 Classics, 2-80gb, 1-160gb)  I've tried 256kbps, 190kbps, and 128kbps compression rates.  All using AAC, all synced with a Mac Mini with Mountain Lion and the latest software for iTunes and the iPods.  It do

  • Interactive Employee Handbook in Flash?

    I have been given the task to generate a new employee handbook / standard operating procedures manual, and I want to make it a digital, interactive file in lieu of a boring old notebook. I'm pretty familiar with Photoshop & InDesign, but am self-teac