Generic Data Extraction : Setting of Upper and Lower Limits

Hi all,
I'm doing the delta extraction for this non-standard infocube which stores data about measuring documents. The strategy I used was to first update a ODS with the new/changed measuring documents determined by their last changed date. Then it will update the infocube with the new values. In order to get the delta measuring documents to go into the ODS, I specify a upper limit of 1 and lower limit of 0 in the extractor's generic delta settings to get measuring documents that are created/changed the previous day. But the system will still take in the full set of measuring document.
Is there something that I have missed out?
Thanks

Hi,
I dont see anything wrong with what you have done. That is correct, it is recommended that the upper safety interval should be set to 1.
But according to you, the system still gets the newly changed records as of current day. Have you checked the update mode? It should be <b>DELTA UPDATE</b>. It might be marked as <b>FULL UPDATE</b>.
Have you successfully initialized the <b>DELTA Update</b>?
Are you using an appropriate DELTA field? It should be a Calendar Day.
Hope I did help and if i did, please grant points...
--Jkyle

Similar Messages

  • Graph of Multiple Numeric Result displaying measurements and upper and lower limits

    Is there a way with your graph control to show all the measured values against upper and lower limits in the same graph?. I can display individual lines, but would like to show all the data on the one graph. The woefully cryptic help files you provide with the graph control in TestStand seriously needs attention (Give examples!) also axis labelling, how is that achieved?

    Hey Brian,
    I'm not sure I understand what you're wanting to see with the data plotted on the graph--would it be possible for you to show us an example, even if it's just a drawn mockup of what the graph would look like? I'd like to look into it a bit and confirm that there is not a way to display the data.
    Also, could you provide a bit of detail about the problems you've run into with using external languages with the ATML and XML reports? I'd like to understand that issue a bit better as well to determine how we could address it.
    One thing you might be interested in is that we can currently embed images in the report by inserting HTML code linking to the image. I've seen cases where a LabVIEW VI plotted some data onto a custom graph, saved a picture of the control, and linked the image into the report. Here is a KnowledgeBase article which describes how the linking process works: http://digital.ni.com/public.nsf/allkb/D98A271E30431C9D86256C230079843A?OpenDocument
    I'll look forward to your reply about what you're hoping to see, and perhaps we can think of the best way to accomplish it with the reporting mechanism in TestStand. As Chiara mentioned, if there are features you would like to see that are not currently possible with our reports, the Idea Exchange will be a great place to post that. 
    Thanks!
    Daniel E.
    TestStand Product Support Engineer
    National Instruments

  • Meter reading upper and lower limits

    Hello,
    Does anyone know how the structure REL16_RANGE in the form class  IS_U_DM_MR_DOWNLOAD gets filled? I need to find the place where the upper and lower limits are filled and how to manipulate, i.e. to correct them.  Where, which table, are these values coming from?
    thanks,
    melinda

    GO to se38 t-code give report name IEEL16R2
    Line no : 2287.
    form fill_reading_ranges using x_reading like t_reading
                                                     y_ranges  like rel16_range.
    This form wil fill your structure REL16_RANGE.
    first it will serach for the billing documnet...then it will find out the rate category,rate then it will search for the tolearnce limit.
    Then Upper limit.
          convert lower limit 1 MR result into display format*
            call function 'ISU_METER_IDDATA_TRANSFORM'
          convert upper limit 1 MR result into display format*
            call function 'ISU_METER_IDDATA_TRANSFORM'
    Please let me know if you need any more information.
    Regards,
    Siva

  • OMR6 upper and lower limits

    I am developer and this is not my area of expertise, so not sure if wording will be correct.  I believe We place payments blocks on invoices based on values set in OMR6.  This is where the configuration is done.  However I have been told that the system will not do this for lower limits.  Can this be done in OMR6 or is there another area we can do this without having to create a user exit?  I'm told that upper limits work fine but that the design of the system does not allow this for lower limits.  Anyone have any ideas of where configuration can be done for this?

    I had someone here walk me through what was in the setup.  For the the Tolerance key "PP" for this specific company there is an upper and lower limit entered and the "check limit" is selected for both upper and lower entries.  The upper limit check works but the lower limit check does not work.  They said, all SAP notes say you have to enable a specific user exit to get the lower limit to work for "PP".  This does not sound right but might be true.  Is there something special you have to do with the "PP" type to get it to work?  I cannot imagine SAP having the lower limit entry there but not using it, but like I said it is possible.

  • Upper and lower limits on Chart

    I am using crystal version 9
    On a line graph is there a way to add an upper and lower limit line on the chart
    Thanks

    Did you remember to turn off autoscaling?  If not, it'll scale right back.  Otherwise, you should have the correct property node.

  • Upper and Lower limits of Counter Instruments

     

    Hi,
    I dont see anything wrong with what you have done. That is correct, it is recommended that the upper safety interval should be set to 1.
    But according to you, the system still gets the newly changed records as of current day. Have you checked the update mode? It should be <b>DELTA UPDATE</b>. It might be marked as <b>FULL UPDATE</b>.
    Have you successfully initialized the <b>DELTA Update</b>?
    Are you using an appropriate DELTA field? It should be a Calendar Day.
    Hope I did help and if i did, please grant points...
    --Jkyle

  • Set High and Low Limits for an Item

    Hello Experts,
    We want to set up HI and Low Limits in SAP so that they can help us know when we are low on an Item. We would like to see when we are in a sales order and place an order for an Item that falls below the low limit the system will let us know and still allow us to place the order.
    The Low limits have to go on what is in inventory in warehouse 1 not what is on order. We would also like to be able to run a report that allows us to see what items are below the low limit and also which items are close to the low limit. ( Comparison Report).
    Any help in the above scenario would be appreciated.
    Regards,
    Praneeth

    Hi Parneeth,
    have you fill the data in item master data --> inventory tab --> minimum & maximum inventory level.
    u can define this for each warehouse.
    may this help u..
    Thanks,
    JRAJPUT
    Edited by: J2663312 on Jul 14, 2010 12:19 PM

  • Delta in Generic data extraction

    Hi all,
    I have a doubt here,
    What is the delta in Generic Data extraction?
    What are the types?
    and what are their significances?
    Please give reply.
    Thanks
    Surya.

    Hi Surya,
    If a field (date, progressive document number, timestamp) exists in the extract structure of a DataSource that contains values which increase monotonously over time, you can define delta capability for this DataSource. If such a delta-relevant field exists in the extract structure, such as a timestamp, the system determines the data volume transferred in the delta method by comparing the maximum value transferred with the last load with the amount of data that has since entered the system.  Only the data that has newly arrived is transferred.
    To get the delta, generic delta management translates the update mode into a selection criterion. The selection of the request is enhanced with an interval for the delta-relevant field. The lower limit of the interval is known from the previous extraction. The upper limit is taken from the current value, such as the timestamp or the time of extraction. You can use security intervals to ensure that all data is taken into consideration in the extractions (The purpose of a security interval is to make the system take into consideration records that appear during the extraction process but which remain unextracted -since they have yet to be saved- during the next extraction; you have the option of adding a security interval to the upper limit/lower limit of the interval).
    After the data request was transferred to the extractor, and the data was extracted, the extractor then informs generic delta management that the pointer can be set to the upper limit of the previously returned interval.
    Hope now is clearer...
    Bye,
    Roberto

  • Read the signal value that pass over the upper and lower limit..

    how to create the system which can read the signal value that pass the lower and upper limit? i've try but the system only read the value that in range of upper and lower limit..thanks..

    Im not very sure if this system can read the value that pass over the limit..because at the save file data so many value(i will attach that file)..and i dont know how to setting to get the failure values only..
    Actually i want to build some system that can read and save value that pass over the limit..i take the signal from simulation sine signal..no hardware required..
    im very new with this software and im in learning process..
    A very big thanks to all that helping me..
    save file data from the system
    Channels 8
    Samples 1 1 1 1 1 1 1 1
    Date 2012/03/05 2012/03/05 2012/03/05 2012/03/05 2012/03/05 2012/03/05 2012/03/05 2012/03/05
    Time 12:30:11.099999 12:30:11.216 12:30:11.216 12:30:11.216 12:30:11.099999 12:30:11.216 12:30:11.216 12:30:11.216
    X_Dimension Time Time Time Time Time Time Time Time
    X0 1.0000000000000001E-1 1.0000000000000001E-1 1.0000000000000001E-1 1.0000000000000001E-1 1.0000000000000001E-1 1.0000000000000001E-1 1.0000000000000001E-1 1.0000000000000001E-1
    Delta_X 0.001000 0.001000 0.001000 0.001000 0.001000 0.001000 0.001000 0.001000
    ***End_of_Header***
    X_Value Sine (Negative Peak) Failures (Negative Peak) Upper Limit (Negative Peak) Lower Limit (Negative Peak) Sine (Positive Peak) Failures (Positive Peak) Upper Limit (Positive Peak) Lower Limit (Positive Peak) Comment
    0.100000 -6.999066 -6.999066 5.000000 -5.000000 6.999136 6.999136 5.000000 -5.000000
    0.200000 -6.998993 -6.998993 5.000000 -5.000000 6.999204 6.999204 5.000000 -5.000000
    0.300000 -6.998917 -6.998917 5.000000 -5.000000 6.999269 6.999269 5.000000 -5.000000
    0.400000 -6.998838 -6.998838 5.000000 -5.000000 6.999331 6.999331 5.000000 -5.000000
    0.500000 -6.998756 -6.998756 5.000000 -5.000000 6.999391 6.999391 5.000000 -5.000000
    0.600000 -6.998672 -6.998672 5.000000 -5.000000 6.999447 6.999447 5.000000 -5.000000
    0.700000 -6.998585 -6.998585 5.000000 -5.000000 6.999501 6.999501 5.000000 -5.000000
    0.800000 -6.998495 -6.998495 5.000000 -5.000000 6.999552 6.999552 5.000000 -5.000000
    0.900000 -6.998403 -6.998403 5.000000 -5.000000 6.999601 6.999601 5.000000 -5.000000
    1.000000 -6.998307 -6.998307 5.000000 -5.000000 6.999646 6.999646 5.000000 -5.000000
    1.100000 -6.998209 -6.998209 5.000000 -5.000000 6.999689 6.999689 5.000000 -5.000000
    1.200000 -6.998108 -6.998108 5.000000 -5.000000 6.999729 6.999729 5.000000 -5.000000
    1.300000 -6.998005 -6.998005 5.000000 -5.000000 6.999766 6.999766 5.000000 -5.000000
    1.400000 -6.997898 -6.997898 5.000000 -5.000000 6.999801 6.999801 5.000000 -5.000000
    1.500000 -6.997789 -6.997789 5.000000 -5.000000 6.999833 6.999833 5.000000 -5.000000
    1.600000 -6.997677 -6.997677 5.000000 -5.000000 6.999862 6.999862 5.000000 -5.000000
    1.700000 -6.997563 -6.997563 5.000000 -5.000000 6.999888 6.999888 5.000000 -5.000000
    1.800000 -6.997445 -6.997445 5.000000 -5.000000 6.999912 6.999912 5.000000 -5.000000
    1.900000 -6.997325 -6.997325 5.000000 -5.000000 6.999932 6.999932 5.000000 -5.000000
    2.000000 -6.997202 -6.997202 5.000000 -5.000000 6.999950 6.999950 5.000000 -5.000000
    2.100000 -6.997076 -6.997076 5.000000 -5.000000 6.999965 6.999965 5.000000 -5.000000
    2.200000 -6.996948 -6.996948 5.000000 -5.000000 6.999978 6.999978 5.000000 -5.000000
    2.300000 -6.996817 -6.996817 5.000000 -5.000000 6.999988 6.999988 5.000000 -5.000000
    2.400000 -6.996683 -6.996683 5.000000 -5.000000 6.999994 6.999994 5.000000 -5.000000
    2.500000 -6.996546 -6.996546 5.000000 -5.000000 6.999999 6.999999 5.000000 -5.000000
    2.600000 -6.996546 -6.996546 5.000000 -5.000000 7.000000 7.000000 5.000000 -5.000000
    2.700000 -6.996683 -6.996683 5.000000 -5.000000 6.999994 6.999994 5.000000 -5.000000
    2.800000 -6.996817 -6.996817 5.000000 -5.000000 6.999988 6.999988 5.000000 -5.000000
    2.900000 -6.996948 -6.996948 5.000000 -5.000000 6.999978 6.999978 5.000000 -5.000000
    3.000000 -6.997076 -6.997076 5.000000 -5.000000 6.999965 6.999965 5.000000 -5.000000
    3.100000 -6.997202 -6.997202 5.000000 -5.000000 6.999950 6.999950 5.000000 -5.000000
    3.200000 -6.997325 -6.997325 5.000000 -5.000000 6.999932 6.999932 5.000000 -5.000000
    3.300000 -6.997445 -6.997445 5.000000 -5.000000 6.999912 6.999912 5.000000 -5.000000
    3.400000 -6.997563 -6.997563 5.000000 -5.000000 6.999888 6.999888 5.000000 -5.000000
    3.500000 -6.997677 -6.997677 5.000000 -5.000000 6.999862 6.999862 5.000000 -5.000000
    3.600000 -6.997789 -6.997789 5.000000 -5.000000 6.999833 6.999833 5.000000 -5.000000
    3.700000 -6.997898 -6.997898 5.000000 -5.000000 6.999801 6.999801 5.000000 -5.000000
    3.800000 -6.998005 -6.998005 5.000000 -5.000000 6.999766 6.999766 5.000000 -5.000000
    3.900000 -6.998108 -6.998108 5.000000 -5.000000 6.999729 6.999729 5.000000 -5.000000
    4.000000 -6.998209 -6.998209 5.000000 -5.000000 6.999689 6.999689 5.000000 -5.000000
    4.100000 -6.998307 -6.998307 5.000000 -5.000000 6.999646 6.999646 5.000000 -5.000000
    4.200000 -6.998403 -6.998403 5.000000 -5.000000 6.999601 6.999601 5.000000 -5.000000
    4.300000 -6.998495 -6.998495 5.000000 -5.000000 6.999552 6.999552 5.000000 -5.000000
    4.400000 -6.998585 -6.998585 5.000000 -5.000000 6.999501 6.999501 5.000000 -5.000000
    4.500000 -6.998672 -6.998672 5.000000 -5.000000 6.999447 6.999447 5.000000 -5.000000
    4.600000 -6.998756 -6.998756 5.000000 -5.000000 6.999391 6.999391 5.000000 -5.000000
    4.700000 -6.998838 -6.998838 5.000000 -5.000000 6.999331 6.999331 5.000000 -5.000000
    4.800000 -6.998917 -6.998917 5.000000 -5.000000 6.999269 6.999269 5.000000 -5.000000
    4.900000 -6.998993 -6.998993 5.000000 -5.000000 6.999204 6.999204 5.000000 -5.000000
    5.000000 -6.999066 -6.999066 5.000000 -5.000000 6.999136 6.999136 5.000000 -5.000000
    5.100000 -6.999136 -6.999136 5.000000 -5.000000 6.999066 6.999066 5.000000 -5.000000
    5.200000 -6.999204 -6.999204 5.000000 -5.000000 6.998993 6.998993 5.000000 -5.000000
    5.300000 -6.999269 -6.999269 5.000000 -5.000000 6.998917 6.998917 5.000000 -5.000000
    5.400000 -6.999331 -6.999331 5.000000 -5.000000 6.998838 6.998838 5.000000 -5.000000
    5.500000 -6.999391 -6.999391 5.000000 -5.000000 6.998756 6.998756 5.000000 -5.000000
    5.600000 -6.999447 -6.999447 5.000000 -5.000000 6.998672 6.998672 5.000000 -5.000000
    5.700000 -6.999501 -6.999501 5.000000 -5.000000 6.998585 6.998585 5.000000 -5.000000
    5.800000 -6.999552 -6.999552 5.000000 -5.000000 6.998495 6.998495 5.000000 -5.000000
    5.900000 -6.999601 -6.999601 5.000000 -5.000000 6.998403 6.998403 5.000000 -5.000000
    6.000000 -6.999646 -6.999646 5.000000 -5.000000 6.998307 6.998307 5.000000 -5.000000
    6.100000 -6.999689 -6.999689 5.000000 -5.000000 6.998209 6.998209 5.000000 -5.000000
    6.200000 -6.999729 -6.999729 5.000000 -5.000000 6.998108 6.998108 5.000000 -5.000000
    6.300000 -6.999766 -6.999766 5.000000 -5.000000 6.998005 6.998005 5.000000 -5.000000
    6.400000 -6.999801 -6.999801 5.000000 -5.000000 6.997898 6.997898 5.000000 -5.000000
    6.500000 -6.999833 -6.999833 5.000000 -5.000000 6.997789 6.997789 5.000000 -5.000000
    6.600000 -6.999862 -6.999862 5.000000 -5.000000 6.997677 6.997677 5.000000 -5.000000
    6.700000 -6.999888 -6.999888 5.000000 -5.000000 6.997563 6.997563 5.000000 -5.000000
    6.800000 -6.999912 -6.999912 5.000000 -5.000000 6.997445 6.997445 5.000000 -5.000000
    6.900000 -6.999932 -6.999932 5.000000 -5.000000 6.997325 6.997325 5.000000 -5.000000
    7.000000 -6.999950 -6.999950 5.000000 -5.000000 6.997202 6.997202 5.000000 -5.000000
    7.100000 -6.999965 -6.999965 5.000000 -5.000000 6.997076 6.997076 5.000000 -5.000000
    7.200000 -6.999978 -6.999978 5.000000 -5.000000 6.996948 6.996948 5.000000 -5.000000
    7.300000 -6.999988 -6.999988 5.000000 -5.000000 6.996817 6.996817 5.000000 -5.000000
    7.400000 -6.999994 -6.999994 5.000000 -5.000000 6.996683 6.996683 5.000000 -5.000000
    7.500000 -6.999999 -6.999999 5.000000 -5.000000 6.996546 6.996546 5.000000 -5.000000
    7.600000 -7.000000 -7.000000 5.000000 -5.000000 6.996546 6.996546 5.000000 -5.000000
    7.700000 -6.999994 -6.999994 5.000000 -5.000000 6.996683 6.996683 5.000000 -5.000000
    7.800000 -6.999988 -6.999988 5.000000 -5.000000 6.996817 6.996817 5.000000 -5.000000
    7.900000 -6.999978 -6.999978 5.000000 -5.000000 6.996948 6.996948 5.000000 -5.000000
    8.000000 -6.999965 -6.999965 5.000000 -5.000000 6.997076 6.997076 5.000000 -5.000000
    8.100000 -6.999950 -6.999950 5.000000 -5.000000 6.997202 6.997202 5.000000 -5.000000

  • Generic Data Extraction From SAP R/3 to BI server using Function Module

    Hi,
    I want step by step procedure for Generic Extraction from SAP R/3 application to BI application
    using Functional module.
    If any body have any Document or any PPT then please reply and post it in forum, i will give point for them.
    Thanks & Regards
    Subhasis Pan

    please go thr this link
    [SAP BI Generic Extraction Using a Function Module|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/library/business-intelligence/s-u/sap%20bi%20generic%20extraction%20using%20a%20function%20module.pdf]
    [Generic Data Extraction Using Function Module |Re: Generic Data Extraction Using Function Module;

  • My SD video keeps jumping between the upper and lower frames. So the video starts frame blending and blurring in and out.

    My SD video keeps jumping between the upper and lower frames.  So the video starts frame blending and blurring in and out.  The sequence settings are set to
    Editing Mode: DV NTSC 29.97 frames/second. 
    Pixel Aspect Ration: D1/DV NTSC (0.9091)
    Fileds: Lower Field First
    Display Format: 30fps Non-Drop-Frame Timecode
    720 x480

    What is the source of your video, and exactly what is inside your video?
    Report back with the codec details of your file, use the programs below... A screen shot works well to SHOW people what you are doing
    http://forums.adobe.com/thread/592070?tstart=30 for screen shot instructions
    Free programs to get file information for PC/Mac http://mediaarea.net/en/MediaInfo/Download

  • MIC with different upper and lower limit

    Hi experts,
    I have a scenario where I have a characteristic to be tested for trace element in a chemical.
    But the upper and lower specification of this MIC is different for different chemicals (material numbers) . ie the specification depends on chemical (material) to be inspected.
    So I am stuck with a combination a number of MICs with same trace element (say iron) to be tested for a number of chemicals.
    How does QM handle this scenario ?
    Rgds
    JMG

    1st - Are you batch managed?  if so you can create a batch class and add a general characteristic to it linked to a single MIC.  Use this MIC in your inspection plans.  Then in the batch class set the specs limits.
    You can create a separate batch class for each group of materials.  I.e. those with the same specs.
    You can also modify the spec value in the classification view for each material that is different then the spec in the class.
    You can also create plans which use the same MIC but in the plan you unlock it and set the spec.  Then assign all the materials using that spec to the same plan.
    This is all very simplied above.  But under NO circumstances should it be necessary to create multiple MICS for the same test with all different specs!
    Craig

  • Upper- and lower case filenames

    I have two Mac OS Extended (journaled) drives with one on my laptop and one on my desktop. I sometimes get an error that reads:
    "You can't copy some of these items because their names are the same as other items on the destination volume, and that volume does not distinguish between upper and lower case letters in filenames. Do you want to skip these items and continue copying other items?"
    Recently this happened when trying to force move (using the Command Key) data from my iDisk to my desktop hard drive.
    Does anyone know what is going on here?
    Is it advisable to first copy data to the desktop on the volume that you are moving to and then move it onto the harddrive and if so what is the reason for this?
    Thanks,
    Jon

    Hi Kappy.
    Thanks. Good information. Are you saying you can only /move/ across filesystems or disk volumes or are you saying you can only /copy/ across filesystems or disk volumes.
    My impression was that going from one hard drive to another hard drive - that the default was copy, but that you could force a move by holding down the Command Key. When I do this over here the little green plus symbol goes away seeming to imply that it is moving. However, /sometimes/ the dialog says it is Copying and sometime is says it is Moving.
    The problem is when it craps out in the middle of a Move (or a Copy). Ignoring the dupe file names with caps issue for the moment - what are you supposed to do when you get through a Move or a Copy (from Hard Drive to Hard Drive for instance) and Finder presents you with an error?!
    My understanding of your explanation is that Finder has gotten part way through a Copy and/or (?!) part way through an Erase.
    Is there any way of understanding WHERE it has gotten when it says it cannot complete an operation because filexyz.pdf is in use (even when it is not)? If I am moving 100 GB of data (or whatever) how am I supposed to know if it has only Copied some information, Copied and Erased some information, Moved some information, or Moved and Erased some information?
    Irrespective of the amount of data, when you get to the point that you cannot reasonably be expected to manually sort through this data how in the world am I supposed to know what Finder has done? More importantly, what is the best way to get back to a point at which you know what information is where?
    Thanks,
    Jon
    P.S. I'm moving data in Target Disk mode at this point and I am not getting errors like "The operation can't be completed because an item with the name "folder 100" already exists - WHEN I HAVE ALREADY SELECTED APPLY TO ALL AND OVERWRITE EXISTING FILES.

  • Upper and lower case Username creates Contact, Calendar, Note acces problems

    Dear All
    Maybe someone has a solution for this or discovered the same case. Our server infrastructer is using Username with upper and lower case letters e.g "Galler".
    Pushing these access data (Username, server adress etc.) for E-Mail, Contact, Calendar and Notes via the profile manager creates problems for the Contact, Calendar and Notes access, because profiles is rechanging the username in all lower case letters "galler". For the E-Mail it is not the case.
    Every help would be very appreciated. Maybe some solution in using username alias with only lower case letters, but I don't no how to establish.
    Thanks in advance for your help.

    Perre wrote:I'm used to being able to pick one or a couple of songs and then adding it a specified playlist. Is this impossible in sonata?
    It's clearly not impossible, just different than you expect. Create your playlist as you want it to appear in the Current tab (meaning don't dump every single song from your library in there, just the ones you want) and then save the playlist.
    Perre wrote:And if I try to play the m3u file created (the one with every song listed) through freevo I get a message that the directory is empty. What am I doing wrong??
    Look at save_absolute_paths_in_playlists in your mpd.conf.

  • UPPER and lower case file extensions for Photo Shop Elements using Windows 7

    How do I persuade WIndows 7 to show both UPPER and lower case file extensions, which is a very useful facility offered by my ancient, 2002, version of Photoshop Elements? When processing large volumes (100 plus) photos it is very useful to be able to spot those that have been processed among those awaiting my gentle touch. The JPEG file extension produced by my camera is UPPER case so by using "Save as" with lower case the modified photos are immediately spotted. This worked fine on Windows XP and the same programme has loaded and works well on my new laptop which came loaded with Windows 7 EXCEPT that it persists in using UPPER case all the time, irrespective of the preference settings in PSE. HELP!
    Camperman1

    In PSE there is a facility "File > process multiple files".
    Using this facility you can actually process multiple files at one go and you can easily rename images.
    Addi

Maybe you are looking for

  • Number of columns and effect on performance

    We are trying to improve the performance of our system and have noticed that the number of columns in our select statements has a dramatic, non-linear effect on the performance we see. For a particular query (with a single record returned) retrieving

  • Itunes can't sync

    i tunes would not sync to phone. message said, sync failed to start. how do i fix this?

  • Comparing Xml in a Text Field

    We have a Text field which saves Xml data (not too big, 20 to 40 lines usually), in one of the stored procedures, we are receiving the Xml, which needs to be either inserted or updated based on whether that record already exists in table or not. We a

  • HT201401 how do I disable my phone so that people can text message me on a new non-iphone

    I have followed the steps recommended by you you guys in the troubleshooting, but I am still not able to received texts from certain people that are using iphones

  • Best laptop for Premiere

    What Windows Laptop under $1500 can run Premiere effectively?