Generic Delta...Please help
Hi,
I have used one date field 'ERDAT' in generic delta and data extraction has been done through custom build function module.During delta upload , while debugging of my FM I have found that this delta field 'ERDAT' is taking the date that is 1 day ahead of last data extraction(i.e if I run INIT on 21.02.2006 ERDAT becomes 22.02.2006 or if I run a delta on 23.02.2006 ERDAT becomes 24.02.2006).Is this the way system always taking care of delta relevent field ??
Please help.....
Thanks in advance..
Hi Pousali,
AS Roberto has already said tht it depends on the Safety interval defined by us, however to do so we have got three option to go with.
1) If delta field is Date (Record Create Date or change date), then use Upper Limit of 1 day.
This will load Delta in BW as of yesterday. Leave Lower limit blank.
2) If delta field is Time Stamp, then use Upper Limit of equal to 1800 Seconds (30 minutes).
This will load Delta in BW as of 30 minutes old. Leave Lower limit blank.
3) If delta field is a Numeric Pointer i.e. generated record # like in GLPCA table, then use
Lower Limit. Use count 10-100. Leave upper limit blank. If value 10 is used then last 10
records will be loaded again. If a record is created when load was running, those records
may get lost. To prevent this situation, lower limit can be used to backup the starting
sequence number. This may result in some records being processed more than once.
Hope it helps!!!!
Amit
Similar Messages
-
Error Message : "Importer detected a generic error" Please Help.
My problem is most likely very simple, with the research I've done I've concluded it is one of 2 options(probably):
1. The project settings are wrong - I've tried quite a few within NTSC(where I should be) but the same error occurs. I am using videos taken by my Iphone 4s. I'm just not sure on any of it and couldnt seem to find an answer online.
2. I didn't import them correctly. I've been importing them simply just by clicking on the files from my iPhone's folder while it is plugged in and dragging them into another foler on my computer. I know this isn't correct but I didn't have a importing software and I could still watch them on Windows Media Player so I thought it was fine.
It could be something else but I have everything installed for it to work so I'm not sure. I may need to download a program that allows me to convert specific properties or something?
I'm pretty confused with all the properties to videos and video formatting so I'm having difficulty solving this on my own. Thanks for the help (:>using videos taken by my Iphone 4s
Iphone won't easily edit http://forums.adobe.com/thread/881246
-and http://forums.adobe.com/thread/1011411?tstart=0
-and a fix http://forums.adobe.com/thread/934466 -
How to return a "HttpServletResponse" for generic servlets (please Help me)
I have a servlet that do a call service to another machine( the service
can be so different), and I would like to know if there is possible to
return to the client the "servletresult" in the "httpservletresult" or
something
similar("servletresult" is a class of "bea.jolt". and I utilizes for
conectivity with TUXEDO).
I am doing the call to the servlet in an application java(via URL and
parameteres), not in browser.
I don´t know which are the parameters to return , and i would like to
manipule these parameters in the client. So, i want don´t use
"getParameterValues" of "servletresult".
I would like to return a object java. It is like to say that the result of
the service call ("servletresult") is passed directly to the
"httpservletresponse" and not pass every parameter (read by name ) between
"servletresult" and "httpservletresponse".
Thanks
I have a servlet that do a call service to another machine( the service
can be so different), and I would like to know if there is possible to
return to the client the "servletresult" in the "httpservletresult" or
something
similar("servletresult" is a class of "bea.jolt". and I utilizes for
conectivity with TUXEDO).
I am doing the call to the servlet in an application java(via URL and
parameteres), not in browser.
I don´t know which are the parameters to return , and i would like to
manipule these parameters in the client. So, i want don´t use
"getParameterValues" of "servletresult".
I would like to return a object java. It is like to say that the result of
the service call ("servletresult") is passed directly to the
"httpservletresponse" and not pass every parameter (read by name ) between
"servletresult" and "httpservletresponse".
Thanks
-
K7N2 Delta....please help
OK, let me start by saying that I know just enough to be dangerous (and really get things screwed up). With that said, My computer was running great and then I had the chance to upgrade my processor and RAM so I did. Since doing so I've run into a little snag, most of the time, about every 60 seconds it just freezes up for anywhere from 3 to 10 sec.
Does anyone have any ideas? Here's my setup:
K7N2 Delta ILSR (MS-6570) I just changed the Bios to version 7.80
Athlon XP 3200+ running @ 2.20 Ghz (temp is 40-45 C)
(3) 512MB Geil DDR400 PC3200 6-3-3-2 (dual channel mode)
NVIDIA Geforce4 Ti 4200 (w/ dual 19" samsung SyncMaster 191T one DVI one AGP)
Dual 80 gig SATA hard drives
SCSI card w/ benchmark tape back up
liteon CD Burner
Toshiba DVD ROM
1394 net adapter
D bracket
S bracket
3.5" floppy
Creative speakers SBS2.1
Generic case w/ plenty of fans & 450W power supply
XP pro SP2
Other settings:
AGP clock @ defalt setting of 66
AGP voltage 1.5
DRAM voltage 2.7
Vcore-1.64v
+3.3v - 3.23
+5v - 5.10
+12v - 11.85
-12v - -12.69
-5v - -5.20
Items that where changed:
I went from a XP3000+ (333FSB) to the 3200+ (400FSB)
added a stick of RAM
installed SP2
and in an effort to fix the problem updated the bios
I know this board is ram sensitive - so is the added ram the problem?
Is SP2 the problem?
Or is it the 3200+?
Please help.Hello,
What is the model of the memory modules?
Geil PC3200 Value ram Blue heat spreaders?
The timings for that are 2.5-3-3-6 not 2-3-3-6 (assuming you got the value series)
Are you running the memory in SPD mode?
You may also want to test each module with this program.
http://www.memtest.org/download/1.40/memtest86+-1.40.floppy.zip
It will create a bootdisk that cannot be read in windows.
You must then boot from the disk with only 1 module in the PC.
If you get any errors then it is a faulty memory module, test all the modules. -
please help, I need to make a video and cant get in my music.
tuckey2012
For background information, what computer operating system is your Premiere Elements 12 running on?
I could ask you for a lot of details to build a troubleshooting plan. However, in this instance with .m4a file and "importer reported a generic error", I am going to cut to what I believe your workflow problem to be.
You are working with iTunes music. To use them in Premiere Elements (any version), please convert them to .wav file in iTunes.
To do that....
a. Open iTunes and go to Music - File Menu/Add File To Library
b. Edit Menu/Preferences/General and there click on Import Settings
c. In the Import Settings dialog, go to Import Using and set for WAV Encoder.
d. OK out of that area.
In the Music Section/Songs, right click your import, select Create WAV Version
Then right click the WAV Version, select Copy, and then Paste it to the computer desktop
from where you import it into Premiere Elements 12 Expert workspace Add Media/Files and Folders/Project Assets
from where you drag it to one of the audio tracks.
Please let us know if that works for you.
Thanks.
ATR -
Help!
I misplaced / lost my I phone 5 today morning in Toronto at delta Chelsea downtown hotel and I am not able to track it. Please help!
<Personal Information Edited by Host>Unfortunately, if you didnt' enable Find My iPhone on it before it was lost, there is no way to track it. Also, don't post your personal information on a public forum like this.
-
0FI_AP_4 - Delta Extraction Problem - Please help
Hi,
I activated the business content ODS 0FIAP_O03 and the relevant infosource for Accounts Payable and also did the init. In R/3 I created an Invoice using FB60 transaction and Posted the payment using F-53 transaction. I can see the document in BSAK table which the 0FI_AP_4 extractor is using but when I see the delta queue in RSA7 there are 0 records for the extractor 0FI_AP_4 which means the new changes are not pushed to the delta queue. Please help.
Thanks.Hi Thiagu,
Try running a delta load 0FI_AP_4 using the tcode RSA3 in your R/3 system? Are you seeing your document there?
I would also check RAS7 in R/3, and to make sure the delta init has taken properly. You can also check for your document there.
HTH -
premier elements12, putting video clips (mov) in to edit work place time line after photos (jpeg) error message, the importer reported a generic error. ? please help.
TINA54
Thanks for the reply.
Some general comments...
Regarding:
THERE ANY WAY I CAN PUT MULTIPLE RANDUM TRANSITIONS IN TO THE TIME LINE WITH JUST ONE CLICK ? .
There is no transition choice for random transitions across the Premiere Elements 12 workspace Timeline. But, the Elements Organizer 12/Create Menu/Slideshow and its Slideshow Editor does have that random transition choice. So, one possibilitity would be to create your slideshow in Elements Organizer 12 Slideshow Editor and then move the slideshow into Premiere Elements with the Output of Edit with Premiere Elements Editor command.
Pending more details of the slideshow you are creating, I think that you would get your best photo quality and overall results staying with Premiere Elements 12 workspace (1080p) project and the transitions randomized manually.
perhaps applying the default to all (all at the same time),
using Timeline Menu/Apply Default Transition,
and then replacing transitions randomly for the random transition look).
Please let us know if any of that worked for you.
Thanks.
ATR -
Can you please help me regarding Generic data Source
Hello Friends,
I have done generic delta source , In that i found
1) Timestamp
2) 0calday
3) Numeric Pointer
Can you please explain me
And also
Update modes :
Additive Delta
New Status for Changed records
Thanks
PPHi,
If u want ur data source is delta enabled u vl come up vt these terms.
There are various delta processes for SAP source systems:
1. Forming deltas with after, before and reverse images that are updated directly in the delta queue; an after image shows the status after the change, a before image the status before the change with a negative sign and the reverse image also shows the negative sign next to the record while indicating it for deletion. This serializes the delta packets. The delta process controls whether adding or overwriting is permitted. In this case, adding and overwriting are permitted. This process supports an update in an ODS object as well as in an InfoCube. (technical name of the delta process in the system): ABR)
2. The extractor delivers additive deltas that are serialized by request. This serialization is necessary since the extractor within a request delivers each key once, and otherwise changes in the non-key fields are not copied over correctly. It only supports the addition of fields. It supports an update in an ODS object as well as in an InfoCube. This delta process is used by LIS DataSources. (technical name of the delta process in the system): ADD)
3. Forming deltas with after image, which are updated directly in the delta queue. This serializes data by packet since the same key can be copied more than once within a request. It does not support the direct update of data in an InfoCube. An ODS object must always be in operation when you update data in an InfoCube. For numeric key figures, for example, this process only supports overwriting and not adding, otherwise incorrect results would come about. It is used in FI-AP/AR for transferring line items, while the variation of the process, where the extractor can also send records with the deletion flag, is used in this capacity in BBP. (technical name of the delta process in the system): AIM/AIMD) -
Please, Help!... K7n2 Delta L And Temp...
well, i´ve a K7N2 DELTA L and noticed that the processor temp., since it began to work, two days ago, is around 47 ~ 51°C in idle mode.... and when i play any game, just like Call of Duty, or RTCW Enemy Territory, it stays around 56 ~ 62°C... is it okay or too hot... I see it in PC ALERT 4....
Please, help!I get the exact same temperatures, 60'C max load though. I don't see it as a problem since I live in Greece and right now the temperature outside is a good 40'C ! During the winter the temps (cpu, case and outside ) drop a lot (don't know how much since I only built my system about a month ago).
For me, under these circumstances, the best cooling option if I want to further drop my temps, is turn on the airconditioner in my room !
Jorge -
I deleted my emails by mistake. Do you know how can I retrieve?? Get I get emails back starting 9/7/2011?? Please help:( THANK YOU
You should never try to sync your phone with more than one computer or you will lose your data. The pictures were not deleted because the sync process does not touch Camera Roll pictures (it only includes them during the backup step of the sync process).
If you had these voice memos on your phone when you last synced it to your first computer, and if you haven't synced to this computer since then, you could restore from the backup created during your last sync. This will replace the data on your phone with the data from this older backup so anything new will be lost. If you think that is the case, do not sync your phone again to the first computer prior to restoring from this backup or you will overwrite it and the backup will be lost. Instead, prior to connecting your phone to your first computer, open iTunes and disable automatic syncing by going to iTunes Preferences and on the Devices tab checking "Prevent...from syncing automatically". Then connect your phone and when it appears in iTunes on the left sidebar right-click on its name and select Restore From Backup and choose your last backup (containing your voice memos).
If you didn't have these voice memos on your phone when you last synced to your first computer, or if you have synced again to your first computer since losing your data, then your voice memos and other data are lost. -
Generic delta - custom table in r3- help needed
hI ALL
I am using a ztable in r3 as data source . i wish to extract data from this table
to my bw ods as a daily delta . i have created a generic data src zds_ztable on the
basis of this table and in the generic delta section selected ' new and changed records' and 'numeric pointer'
options .
however , on the bw side when i try to create an infopackage under the relevant infosrc , it does not give
me an option for ' initialisation' or 'delta ' , i only have option for FULL loads , I know i can use a date
field and do a pseudo delta using technical FULL load ...but i want to know why cant i do an init and then
a delta the way we do for other data srcs....
pls helpHi,
You may go to RSA2 for your datasource in R/3 & check do the delta settings are correct ? or you might need to re-generate the datasource and replicate in BW.
Eddo -
I'm having big problems with my K72N-Delta-L and Apacer ram! Please help!
Well, on almost every boot, the system hangs, starts beeping wildly, and my LEDs tell me that the system is in "early memory detection" .... What now? I have APACER 512mb ddr(266mhz) ... I just can't understand what's going on here... I've tried almost everything! could someone please help out?
Thanks
-MAcording to Msi test report that this ram is not certified. But this may not be the problem. Have you check to see if the ram is seated properly, Also provide the amps on each rails, this will be stated on the psu cover, and the power size of the psu.
I know these boards are power eaters. -
K7n2 Delta RAID Setup ----PLEASE HELP
Can someone explain how a RAID - Striping should be setup on this MOBO? I can not get the board to see the 2nd drive. I have duplicate Maxtor 40gb drives and it will only see one of the drives. I am using IDE3 for one of the drives and then putting the other drive on IDE1. The manual states that you can only have 1 HD on IDE3 thus the reason for setting it up this way. I have also tried the 2 maxtor drives on IDE1 with another drive on IDE3 (dummy RAID) hoping that this config would work as well, but it did not!
Please help!!!!!!!!!!!!!
Thanks in advance for any and all replies.It does support RAID. I have been able to go into the Fastrack utility and setup a RAID consisting of one drive. The manual also states that all IDE slots support RAID. It has the promise 376 chip.
-
Function Module Extraction!! Please HELP!!
Hi Experts,
This is my first project in BW. Please help!! The existing function module using 3 tables to extract (Full update) data. Now, I have to enable the delta for this generic extractor. I have seen RSA3_GET_DATA_SIMPLE (nothing specified for Delta) and RSVD_BW_GET_DELTA_DATA function module to make use of it using OPEN CURSOR but in that fm I can see only one table being used.
Should I use 3 cursors to extract if so how should I join them? Can anyone please help me how to use cursors joining 3 tables and extract right delta data?
This would be a greatest help!! Thanks in advance.
RishiOk please find the original code below before I changed it... please do not mind as I was little scared to give exact tech names sorry... please find the code below.
FUNCTION zz_ods_bw_extract_fm.
""Local Interface:
*" IMPORTING
*" VALUE(I_REQUNR) TYPE SRSC_S_IF_SIMPLE-REQUNR
*" VALUE(I_DSOURCE) TYPE SRSC_S_IF_SIMPLE-DSOURCE OPTIONAL
*" VALUE(I_MAXSIZE) TYPE SRSC_S_IF_SIMPLE-MAXSIZE OPTIONAL
*" VALUE(I_INITFLAG) TYPE SRSC_S_IF_SIMPLE-INITFLAG OPTIONAL
*" VALUE(I_READ_ONLY) TYPE SRSC_S_IF_SIMPLE-READONLY OPTIONAL
*" TABLES
*" I_T_SELECT TYPE SRSC_S_IF_SIMPLE-T_SELECT OPTIONAL
*" I_T_FIELDS TYPE SRSC_S_IF_SIMPLE-T_FIELDS OPTIONAL
*" E_T_DATA STRUCTURE ZZODS_BW_EXTRACT_STRUCT OPTIONAL
*" EXCEPTIONS
*" NO_MORE_DATA
*" ERROR_PASSED_TO_MESS_HANDLER
DATA : t_zzods_extract TYPE zzods_bw_extract_struct OCCURS 0
WITH HEADER LINE.
Local data declarations
DATA: l_output TYPE proj-pspid.
Maximum number of lines for DB table
STATICS: s_s_if TYPE srsc_s_if_simple,
s_counter_datapakid LIKE sy-tabix.
DATA: BEGIN OF t_prps OCCURS 0,
posid TYPE ps_posid,
psphi TYPE ps_psphi,
zzdflt1 TYPE zd_variable,
zzdflt2 TYPE zd_variable,
zzdflt3 TYPE zd_variable,
zzdflt4 TYPE zd_variable,
zzdflt5 TYPE zd_variable,
zzdflt6 TYPE zd_variable,
zzdflt7 TYPE zd_variable,
zzdflt8 TYPE zd_variable,
zzdflt9 TYPE zd_variable,
zzdflt10 TYPE zd_variable,
zzdflt11 TYPE zd_variable,
zzvar1 TYPE zd_var01,
zzvar2 TYPE zd_var02,
zzvar3 TYPE zd_var03,
zzvar4 TYPE zd_var04,
zzvar5 TYPE zd_var05,
zzvar6 TYPE zd_var06,
zzvar7 TYPE zd_var07,
zzvar8 TYPE zd_var08,
zzvar9 TYPE zd_var09,
zzvar10 TYPE zd_var10,
zzvar11 TYPE zd_var09,
zzunit1 TYPE zd_unit01,
zzunit2 TYPE zd_unit02,
zzunit3 TYPE zd_unit03,
zzunit4 TYPE zd_unit04,
zzunit5 TYPE zd_unit05,
zzunit6 TYPE zd_unit06,
zzunit7 TYPE zd_unit07,
zzunit8 TYPE zd_unit08,
zzunit9 TYPE zd_unit09,
zzunit10 TYPE zd_unit10,
zzunit11 TYPE zd_unit11,
zztpemsnar1 TYPE zd_tpemsnar,
zzrprtngyr1 TYPE zd_rprtngyr,
zznonatar1 TYPE zd_nonatr,
zzzcat1 TYPE zd_zcat,
zzslitemar1 TYPE zd_slitemar,
zzbnftyrs1 TYPE zd_bnftyrs,
zzdescfrml TYPE zd_descfrml,
ZZFORMULA type ZD_FRMLUSD,
END OF t_prps.
DATA: BEGIN OF t_emfactor OCCURS 0,
naindex TYPE zd_index,
nayear TYPE zd_year,
cofactor TYPE zd_cofac,
vocfactor TYPE zd_vofac,
noxfactor TYPE zd_nofac,
pmfactor TYPE zd_pmfac,
END OF t_emfactor.
DATA: BEGIN OF t_slef OCCURS 0,
slindex TYPE zd_index,
slyear TYPE zd_year,
sltldfact TYPE zd_sltldfact,
END OF t_slef.
Initialization mode (first call by SAPI) or data transfer mode
(following calls) ?
IF i_initflag = sbiwa_c_flag_on.
Check DataSource validity
CASE i_dsource.
WHEN 'ZZODS_DATA_TRANS'.
WHEN OTHERS.
RAISE error_passed_to_mess_handler.
ENDCASE.
Fill parameter buffer for data extraction calls
s_s_if-requnr = i_requnr.
s_s_if-dsource = i_dsource.
s_s_if-maxsize = i_maxsize.
ELSE. "Initialization mode or data extraction ?
Data transfer: First Call to pupulate data
First data package
IF s_counter_datapakid = 0.
Extract data from prps for Project Types 15 and 17
SELECT posid psphi zzdflt1 zzdflt2 zzdflt3
zzdflt4 zzdflt5 zzdflt6 zzdflt7
zzdflt8 zzdflt9 zzdflt10 zzdflt11
zzvar1 zzvar2 zzvar3 zzvar4 zzvar5
zzvar6 zzvar7 zzvar8 zzvar9 zzvar10
zzvar11 zzunit1 zzunit2 zzunit3 zzunit4
zzunit5 zzunit6 zzunit7 zzunit8
zzunit9 zzunit10 zzunit11
zztpemsnar1 zzrprtngyr1
zznonatar1 zzzcat1 zzslitemar1
zzbnftyrs1 zzdescfrml
FROM prps
INTO TABLE t_prps
WHERE prart = '15' OR prart = '17'.
Check for fetched records
IF sy-subrc EQ 0.
SORT t_prps BY posid.
ENDIF.
If the above condition is true
IF NOT t_prps[] IS INITIAL.
Get the data from z_fact
Data : t_prps1 like t_prps occurs 0 with header line.
SELECT naindex
nayear
cofactor
vocfactor
noxfactor
pmfactor
INTO TABLE t_emfactor
FROM z_fact.
*RR WHERE naindex = t_prps-zztpemsnar1+0(3)
*RR WHERE naindex = l_prps_index
*GP WHERE naindex = '01' or NAINDEX = '03'.
AND nayear = t_prps-zzrprtngyr1.
Sort the data by index and construction year
IF sy-subrc EQ 0.
SORT t_emfactor BY naindex nayear.
ENDIF.
Get the data from ztp_slef
SELECT slindex
slyear
sltldfact
INTO TABLE t_slef
FROM ztp_slef.
*RR WHERE slindex = t_prps-zztpemsnar1+0(3)
*GP WHERE slindex = '01' or slindex = '03'.
*RR AND slyear = t_prps-zzrprtngyr1.
IF sy-subrc EQ 0.
SORT t_slef BY slindex slyear.
ENDIF.
ENDIF.
Between this LOOP and ENDLOOP get the internal value of each project.
Get the required data stored in above internal tables and populate
the extract internal table
LOOP AT t_prps.
CLEAR l_output.
CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT'
EXPORTING
input = t_prps-psphi
IMPORTING
output = l_output.
t_zzods_extract-psphi = l_output.
CLEAR t_emfactor.
READ TABLE t_emfactor WITH KEY NAINDEX = t_prps-zztpemsnar1+0(3)
nayear = t_prps-zzrprtngyr1
BINARY SEARCH.
IF sy-subrc EQ 0.
t_zzods_extract-cofactor = t_emfactor-cofactor.
t_zzods_extract-vocfactor = t_emfactor-vocfactor.
t_zzods_extract-noxfactor = t_emfactor-noxfactor.
t_zzods_extract-pmfactor = t_emfactor-pmfactor.
ENDIF.
CLEAR t_slef.
READ TABLE t_slef WITH KEY slindex = t_prps-ZZSLITEMAR1+0(3)
slyear = t_prps-zzrprtngyr1
BINARY SEARCH.
IF sy-subrc EQ 0.
t_zzods_extract-sltldfact = t_slef-sltldfact.
ELSE.
t_zzods_extract-sltldfact = '0'.
ENDIF.
t_zzods_extract-posid = t_prps-posid.
t_zzods_extract-zzdflt1 = t_prps-zzdflt1.
t_zzods_extract-zzdflt2 = t_prps-zzdflt2.
t_zzods_extract-zzdflt3 = t_prps-zzdflt3.
t_zzods_extract-zzdflt4 = t_prps-zzdflt4.
t_zzods_extract-zzdflt5 = t_prps-zzdflt5.
t_zzods_extract-zzdflt6 = t_prps-zzdflt6.
t_zzods_extract-zzdflt7 = t_prps-zzdflt7.
t_zzods_extract-zzdflt8 = t_prps-zzdflt8.
t_zzods_extract-zzdflt9 = t_prps-zzdflt9.
t_zzods_extract-zzdflt10 = t_prps-zzdflt10.
t_zzods_extract-zzdflt11 = t_prps-zzdflt11.
t_zzods_extract-zzvar1 = t_prps-zzvar1.
t_zzods_extract-zzvar2 = t_prps-zzvar2.
t_zzods_extract-zzvar3 = t_prps-zzvar3.
t_zzods_extract-zzvar4 = t_prps-zzvar4.
t_zzods_extract-zzvar5 = t_prps-zzvar5.
t_zzods_extract-zzvar6 = t_prps-zzvar6.
t_zzods_extract-zzvar7 = t_prps-zzvar7.
t_zzods_extract-zzvar8 = t_prps-zzvar8.
t_zzods_extract-zzvar9 = t_prps-zzvar9.
t_zzods_extract-zzvar10 = t_prps-zzvar10.
t_zzods_extract-zzvar11 = t_prps-zzvar11.
t_zzods_extract-zzunit1 = t_prps-zzunit1.
t_zzods_extract-zzunit2 = t_prps-zzunit2.
t_zzods_extract-zzunit3 = t_prps-zzunit3.
t_zzods_extract-zzunit4 = t_prps-zzunit4.
t_zzods_extract-zzunit5 = t_prps-zzunit5.
t_zzods_extract-zzunit6 = t_prps-zzunit6.
t_zzods_extract-zzunit7 = t_prps-zzunit7.
t_zzods_extract-zzunit8 = t_prps-zzunit8.
t_zzods_extract-zzunit9 = t_prps-zzunit9.
t_zzods_extract-zzunit10 = t_prps-zzunit10.
t_zzods_extract-zzunit11 = t_prps-zzunit11.
t_zzods_extract-zznonatar1 = t_prps-zznonatar1.
t_zzods_extract-zzzcat1 = t_prps-zzzcat1.
t_zzods_extract-zztpemsnar1 = t_prps-zztpemsnar1.
t_zzods_extract-zzslitemar1 = t_prps-zzslitemar1.
t_zzods_extract-zzrprtngyr1 = t_prps-zzrprtngyr1.
t_zzods_extract-zzbnftyrs1 = t_prps-zzbnftyrs1.
t_zzods_extract-zzdescfrml = t_prps-zzdescfrml.
t_ZzODS_EXTRACT-ZZFORMULA = t_prps-ZZFORMULA.
APPEND t_zzods_extract.
CLEAR t_zzods_extract.
ENDLOOP.
Delete the record before filling the custom Records
CLEAR e_t_data.
REFRESH e_t_data.
Submit all the extracted records to extract table
e_t_data[] = t_zzods_extract[].
s_counter_datapakid = s_counter_datapakid + 1.
else.
Raise NO_MORE_DATA.
ENDIF.
s_counter_datapakid = s_counter_datapakid + 1.
ENDIF. "Initialization mode or data extractio
ENDFUNCTION.
Maybe you are looking for
-
IPod Not Recognized by my Computer?
I am using a Windows 7 computer and my iPod is no longer recognized by my computer, or iTunes. It will charge, but not show up on iTunes or even make a sound that shows iTunes knows it's there. So all I get is the charging "ping". I have updated iTun
-
I've tried deleting firefox and redownloading it, but it won't come back. All I have at the top now are bookmarks and open tabs, it's getting really annoying when I want to post or share a web address and I can't because the bar is gone. == This happ
-
I want to backup a user in increasement mode
I know oralce supports increasement backup for entire database(all objects). but I want to backup a user in such mode. who can tell me how to do? thanks.
-
How to transfert the files from my Ipod to a new computer without erasing it?
My computer died and now I want to transfert the files of my Ipod on my new one. How do I have to procede, because itunes want to reset my Ipod?
-
Cannot Open MX2004 Flash File in Flash 8
I have a serious problem. I created a website using Flash MX2004 and have since upgrade to Flash 8. Now he wants me to update his website and every time I try to open the origional file in Flash 8 it just locks up the program. I really need to find o