Generic Delta...Please help

Hi,
I have used one date field 'ERDAT' in generic delta and data extraction has been done through custom build function module.During delta upload , while debugging of my FM I have found that this delta field 'ERDAT' is taking the date that is 1 day ahead of last data extraction(i.e if I run INIT on 21.02.2006 ERDAT becomes 22.02.2006 or if I run a delta on 23.02.2006 ERDAT becomes 24.02.2006).Is this the way system always taking care of delta relevent field ??
Please help.....
Thanks in advance..

Hi Pousali,
    AS Roberto has already said tht it depends on the Safety interval defined by us, however to do so we have got three option to go with.
1) If delta field is Date (Record Create Date or change date), then use Upper Limit of 1 day.
This will load Delta in BW as of yesterday. Leave Lower limit blank.
2) If delta field is Time Stamp, then use Upper Limit of equal to 1800 Seconds (30 minutes).
This will load Delta in BW as of 30 minutes old. Leave Lower limit blank.
3) If delta field is a Numeric Pointer i.e. generated record # like in GLPCA table, then use
Lower Limit. Use count 10-100. Leave upper limit blank. If value 10 is used then last 10
records will be loaded again. If a record is created when load was running, those records
may get lost. To prevent this situation, lower limit can be used to backup the starting
sequence number. This may result in some records being processed more than once.
Hope it helps!!!!
Amit

Similar Messages

  • Error Message : "Importer detected a generic error" Please Help.

    My problem is most likely very simple, with the research I've done I've concluded it is one of 2 options(probably):
    1. The project settings are wrong - I've tried quite a few within NTSC(where I should be) but the same error occurs. I am using videos taken by my Iphone 4s. I'm just not sure on any of it and couldnt seem to find an answer online.
    2. I didn't import them correctly. I've been importing them simply just by clicking on the files from my iPhone's folder while it is plugged in and dragging them into another foler on my computer. I know this isn't correct but I didn't have a importing software and I could still watch them on Windows Media Player so I thought it was fine.
    It could be something else but I have everything installed for it to work so I'm not sure. I may need to download a program that allows me to convert specific properties or something?
    I'm pretty confused with all the properties to videos and video formatting so I'm having difficulty solving this on my own. Thanks for the help (:

    >using videos taken by my Iphone 4s
    Iphone won't easily edit http://forums.adobe.com/thread/881246
    -and http://forums.adobe.com/thread/1011411?tstart=0
    -and a fix http://forums.adobe.com/thread/934466

  • How to return a "HttpServletResponse" for generic servlets (please Help me)

    I have a servlet that do a call service to another machine( the service
              can be so different), and I would like to know if there is possible to
              return to the client the "servletresult" in the "httpservletresult" or
              something
              similar("servletresult" is a class of "bea.jolt". and I utilizes for
              conectivity with TUXEDO).
              I am doing the call to the servlet in an application java(via URL and
              parameteres), not in browser.
              I don´t know which are the parameters to return , and i would like to
              manipule these parameters in the client. So, i want don´t use
              "getParameterValues" of "servletresult".
              I would like to return a object java. It is like to say that the result of
              the service call ("servletresult") is passed directly to the
              "httpservletresponse" and not pass every parameter (read by name ) between
              "servletresult" and "httpservletresponse".
              Thanks
              

    I have a servlet that do a call service to another machine( the service
              can be so different), and I would like to know if there is possible to
              return to the client the "servletresult" in the "httpservletresult" or
              something
              similar("servletresult" is a class of "bea.jolt". and I utilizes for
              conectivity with TUXEDO).
              I am doing the call to the servlet in an application java(via URL and
              parameteres), not in browser.
              I don´t know which are the parameters to return , and i would like to
              manipule these parameters in the client. So, i want don´t use
              "getParameterValues" of "servletresult".
              I would like to return a object java. It is like to say that the result of
              the service call ("servletresult") is passed directly to the
              "httpservletresponse" and not pass every parameter (read by name ) between
              "servletresult" and "httpservletresponse".
              Thanks
              

  • K7N2 Delta....please help

    OK, let me start by saying that I know just enough to be dangerous (and really get things screwed up).  With that said, My computer was running great and then I had the chance to upgrade my processor and RAM so I did.  Since doing so I've run into a little snag, most of the time, about every 60 seconds it just freezes up for anywhere from 3 to 10 sec.  
    Does anyone have any ideas?  Here's my setup:
    K7N2 Delta ILSR (MS-6570)  I just changed the Bios to version 7.80
    Athlon XP 3200+ running @ 2.20 Ghz (temp is 40-45 C)
    (3) 512MB Geil DDR400 PC3200 6-3-3-2 (dual channel mode)
    NVIDIA Geforce4 Ti 4200 (w/ dual 19" samsung SyncMaster 191T one DVI one AGP)
    Dual 80 gig SATA hard drives
    SCSI card w/ benchmark tape back up
    liteon CD Burner
    Toshiba DVD ROM
    1394 net adapter
    D bracket
    S bracket
    3.5" floppy
    Creative speakers SBS2.1
    Generic case w/ plenty of fans & 450W power supply
    XP pro SP2
    Other settings:
    AGP clock @ defalt setting of 66
    AGP voltage 1.5
    DRAM voltage 2.7
    Vcore-1.64v
    +3.3v - 3.23
    +5v - 5.10
    +12v - 11.85
    -12v - -12.69
    -5v - -5.20
    Items that where changed:
    I went from a XP3000+ (333FSB) to the 3200+ (400FSB)
    added a stick of RAM
    installed SP2
    and in an effort to fix the problem updated the bios
    I know this board is ram sensitive - so is the added ram the problem?
    Is SP2 the problem?
    Or is it the 3200+?
    Please help.

    Hello,
    What is the model of the memory modules?
    Geil PC3200 Value ram Blue heat spreaders?
    The timings for that are 2.5-3-3-6 not 2-3-3-6 (assuming you got the value series)
    Are you running the memory in SPD mode?
    You may also want to test each module with this program.
    http://www.memtest.org/download/1.40/memtest86+-1.40.floppy.zip
    It will create a bootdisk that cannot be read in windows.
    You must then boot from the disk with only 1 module in the PC.
    If you get any errors then it is a faulty memory module, test all the modules.

  • In Adobe premiere elements 12 it wont let me add a m4a file. It says that "the importer reported a generic error". Please help.

    please help, I need to make a video and cant get in my music.

    tuckey2012
    For background information, what computer operating system is your Premiere Elements 12 running on?
    I could ask you for a lot of details to build a troubleshooting plan. However, in this instance with .m4a file and "importer reported a generic error", I am going to cut to what I believe your workflow problem to be.
    You are working with iTunes music. To use them in Premiere Elements (any version), please convert them to .wav file in iTunes.
    To do that....
    a. Open iTunes and go to Music - File Menu/Add File To Library
    b. Edit Menu/Preferences/General and there click on Import Settings
    c. In the Import Settings dialog, go to Import Using and set for WAV Encoder.
    d. OK out of that area.
    In the Music Section/Songs, right click your import, select Create WAV Version
    Then right click the WAV Version, select Copy, and then Paste it to the computer desktop
    from where you import it into Premiere Elements 12 Expert workspace Add Media/Files and Folders/Project Assets
    from where you drag it to one of the audio tracks.
    Please let us know if that works for you.
    Thanks.
    ATR

  • HT4759 Help!!! I misplaced/lost my iPhone 5 today morning in Toronto at Delta Chelsea Downtown and I am not able to track it. Please help!!!

    Help!
    I misplaced / lost my I phone 5 today morning in Toronto at delta Chelsea downtown hotel and I am not able to track it. Please help!
    <Personal Information Edited by Host>

    Unfortunately, if you didnt' enable Find My iPhone on it before it was lost, there is no way to track it.  Also, don't post your personal information on a public forum like this.

  • 0FI_AP_4 - Delta Extraction Problem - Please help

    Hi,
         I activated the business content ODS 0FIAP_O03 and the relevant infosource for Accounts Payable and also did the init. In R/3 I created an Invoice using FB60 transaction and Posted the payment using F-53 transaction. I can see the document in BSAK table which the 0FI_AP_4 extractor is using but when I see the delta queue in RSA7 there are 0 records for the extractor 0FI_AP_4 which means the new changes are not pushed to the delta queue. Please help.
    Thanks.

    Hi Thiagu,
    Try running a delta load 0FI_AP_4 using the tcode RSA3 in your R/3 system? Are you seeing your document there?
    I would also check RAS7 in R/3, and to make sure the delta init has taken properly. You can also check for your document there.
    HTH

  • Putting video clips (mov) in to edit work place time line after photos (jpeg) getting error message, the importer reported a generic error. ? please help thanks

    premier elements12, putting video clips (mov) in to edit work place time line after photos (jpeg) error message, the importer reported a generic error. ? please help.

    TINA54
    Thanks for the reply.
    Some general comments...
    Regarding:
    THERE ANY WAY I CAN PUT MULTIPLE RANDUM TRANSITIONS IN TO THE TIME LINE WITH JUST ONE CLICK ? .
    There is no transition choice for random transitions across the Premiere Elements 12 workspace Timeline. But, the Elements Organizer 12/Create Menu/Slideshow and its Slideshow Editor does have that random transition choice. So, one possibilitity would be to create your slideshow in Elements Organizer 12 Slideshow Editor and then move the slideshow into Premiere Elements with the Output of Edit with Premiere Elements Editor command.
    Pending more details of the slideshow you are creating, I think that you would get your best photo quality and overall results staying with Premiere Elements 12 workspace (1080p) project and the transitions randomized manually.
    perhaps applying the default to all (all at the same time),
    using Timeline Menu/Apply Default Transition,
    and then replacing transitions randomly for the random transition look).
    Please let us know if any of that worked for you.
    Thanks.
    ATR

  • Can you please help me regarding Generic data  Source

    Hello Friends,
    I have done generic delta source , In that i found
    1) Timestamp
    2) 0calday
    3) Numeric Pointer
    Can you please explain me
    And also
    Update modes :
    Additive Delta
    New Status for Changed records
    Thanks
    PP

    Hi,
    If u want ur data source is delta enabled u vl come up vt these terms.
    There are various delta processes for SAP source systems:
           1.      Forming deltas with after, before and reverse images that are updated directly in the delta queue; an after image shows the status after the change, a before image the status before the change with a negative sign and the reverse image also shows the negative sign next to the record while indicating it for deletion. This serializes the delta packets. The delta process controls whether adding or overwriting is permitted. In this case, adding and overwriting are permitted. This process supports an update in an ODS object as well as in an InfoCube. (technical name of the delta process in the system): ABR)
           2.      The extractor delivers additive deltas that are serialized by request. This serialization is necessary since the extractor within a request delivers each key once, and otherwise changes in the non-key fields are not copied over correctly. It only supports the addition of fields. It supports an update in an ODS object as well as in an InfoCube. This delta process is used by LIS DataSources. (technical name of the delta process in the system): ADD)
           3.      Forming deltas with after image, which are updated directly in the delta queue. This serializes data by packet since the same key can be copied more than once within a request. It does not support the direct update of data in an InfoCube. An ODS object must always be in operation when you update data in an InfoCube. For numeric key figures, for example, this process only supports overwriting and not adding, otherwise incorrect results would come about. It is used in FI-AP/AR for transferring line items, while the variation of the process, where the extractor can also send records with the deletion flag, is used in this capacity in BBP. (technical name of the delta process in the system): AIM/AIMD)

  • Please, Help!... K7n2 Delta L And Temp...

    well, i´ve a K7N2 DELTA L and noticed that the processor temp., since it began to work, two days ago, is around 47 ~ 51°C in idle mode.... and when i play any game, just like Call of Duty, or RTCW Enemy Territory, it stays around 56 ~ 62°C... is it okay or too hot... I see it in PC ALERT 4....
    Please, help!

    I get the exact same temperatures, 60'C max load though. I don't see it as a problem since I live in Greece and right now the temperature outside is a good 40'C ! During the winter the temps (cpu, case and outside ) drop a lot (don't know how much since I only built my system about a month ago).
    For me, under these circumstances, the best cooling option if I want to further drop my temps, is turn on the airconditioner in my room !
    Jorge

  • Help retrieving deleted emails. I delted my emails by mistake. Does anyone know who to retrieve??? Please HELP:(

    I deleted my emails by mistake. Do you know how can I retrieve?? Get I get emails back starting 9/7/2011?? Please help:( THANK YOU

    You should never try to sync your phone with more than one computer or you will lose your data.  The pictures were not deleted because the sync process does not touch Camera Roll pictures (it only includes them during the backup step of the sync process).
    If you had these voice memos on your phone when you last synced it to your first computer, and if you haven't synced to this computer since then, you could restore from the backup created during your last sync.  This will replace the data on your phone with the data from this older backup so anything new will be lost.  If you think that is the case, do not sync your phone again to the first computer prior to restoring from this backup or you will overwrite it and the backup will be lost.  Instead, prior to connecting your phone to your first computer, open iTunes and disable automatic syncing by going to iTunes Preferences and on the Devices tab checking "Prevent...from syncing automatically".  Then connect your phone and when it appears in iTunes on the left sidebar right-click on its name and select Restore From Backup and choose your last backup (containing your voice memos).
    If you didn't have these voice memos on your phone when you last synced to your first computer, or if you have synced again to your first computer since losing your data, then your voice memos and other data are lost.

  • Generic delta - custom table in r3- help needed

    hI ALL
    I am using a ztable in r3 as data source . i wish to extract data from this table
    to my bw ods as a daily delta . i have created a generic data src zds_ztable on the
    basis of this table and in the generic delta section selected ' new and changed records' and 'numeric pointer'
    options .
    however , on the bw side when i try to create an infopackage under the relevant infosrc , it does not give
    me an option for ' initialisation' or 'delta ' , i only have option for FULL loads , I know i can use a date
    field and do a pseudo delta using technical FULL load ...but i want to know why cant i do an init and then
    a delta the way we do for other data srcs....
    pls help

    Hi,
    You may go to RSA2 for your datasource in R/3 & check do the delta settings are correct ? or you might need to re-generate the datasource and replicate in BW.
    Eddo

  • I'm having big problems with my K72N-Delta-L and Apacer ram! Please help!

    Well, on almost every boot, the system hangs, starts beeping wildly, and my LEDs tell me that the system is in "early memory detection" .... What now? I have APACER 512mb ddr(266mhz) ... I just can't understand what's going on here... I've tried almost everything! could someone please help out?
    Thanks
    -M

    Acording to Msi test report that this ram is not certified.  But this may not be the problem.  Have you check to see if the ram is seated properly, Also provide the amps on each rails, this will be stated on the psu cover, and the power size of the psu.
    I know these boards are power eaters.

  • K7n2 Delta RAID Setup ----PLEASE HELP

    Can someone explain how a RAID - Striping should be setup on this MOBO?  I can not get the board to see the 2nd drive. I have duplicate Maxtor 40gb drives and it will only see one of the drives. I am using IDE3 for one of the drives and then putting the other drive on IDE1. The manual states that you can only have 1 HD on IDE3 thus the reason for setting it up this way.  I have also tried the 2 maxtor drives on IDE1 with another drive on IDE3 (dummy RAID) hoping that this config would work as well, but it did not!
    Please help!!!!!!!!!!!!!
    Thanks in advance for any and all replies.

    It does support RAID. I have been able to go into the Fastrack utility and setup a RAID consisting of one drive. The manual also states that all IDE slots support RAID. It has the promise 376 chip.

  • Function Module Extraction!! Please HELP!!

    Hi Experts,
    This is my first project in BW. Please help!! The existing function module using 3 tables to extract (Full update) data. Now, I have to enable the delta for this generic extractor. I have seen RSA3_GET_DATA_SIMPLE (nothing specified for Delta) and RSVD_BW_GET_DELTA_DATA function module to make use of it using OPEN CURSOR but in that fm I can see only one table being used.
    Should I use 3 cursors to extract if so how should I join them? Can anyone please help me how to use cursors joining 3 tables and extract right delta data?
    This would be a greatest help!! Thanks in advance.
    Rishi

    Ok please find the original code below before I changed it... please do not mind as I was little scared to give exact tech names sorry... please find the code below.
    FUNCTION zz_ods_bw_extract_fm.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(I_REQUNR) TYPE  SRSC_S_IF_SIMPLE-REQUNR
    *"     VALUE(I_DSOURCE) TYPE  SRSC_S_IF_SIMPLE-DSOURCE OPTIONAL
    *"     VALUE(I_MAXSIZE) TYPE  SRSC_S_IF_SIMPLE-MAXSIZE OPTIONAL
    *"     VALUE(I_INITFLAG) TYPE  SRSC_S_IF_SIMPLE-INITFLAG OPTIONAL
    *"     VALUE(I_READ_ONLY) TYPE  SRSC_S_IF_SIMPLE-READONLY OPTIONAL
    *"  TABLES
    *"      I_T_SELECT TYPE  SRSC_S_IF_SIMPLE-T_SELECT OPTIONAL
    *"      I_T_FIELDS TYPE  SRSC_S_IF_SIMPLE-T_FIELDS OPTIONAL
    *"      E_T_DATA STRUCTURE  ZZODS_BW_EXTRACT_STRUCT OPTIONAL
    *"  EXCEPTIONS
    *"      NO_MORE_DATA
    *"      ERROR_PASSED_TO_MESS_HANDLER
      DATA : t_zzods_extract TYPE zzods_bw_extract_struct OCCURS 0
                                                       WITH HEADER LINE.
    Local data declarations
      DATA: l_output TYPE proj-pspid.
    Maximum number of lines for DB table
      STATICS: s_s_if TYPE srsc_s_if_simple,
               s_counter_datapakid LIKE sy-tabix.
      DATA: BEGIN OF t_prps OCCURS 0,
              posid     TYPE     ps_posid,
              psphi     TYPE     ps_psphi,
              zzdflt1     TYPE     zd_variable,
              zzdflt2     TYPE     zd_variable,
              zzdflt3     TYPE     zd_variable,
              zzdflt4     TYPE     zd_variable,
              zzdflt5     TYPE     zd_variable,
              zzdflt6     TYPE     zd_variable,
              zzdflt7     TYPE     zd_variable,
              zzdflt8     TYPE     zd_variable,
              zzdflt9     TYPE     zd_variable,
              zzdflt10     TYPE     zd_variable,
              zzdflt11     TYPE     zd_variable,
              zzvar1     TYPE     zd_var01,
              zzvar2     TYPE     zd_var02,
              zzvar3     TYPE     zd_var03,
              zzvar4     TYPE     zd_var04,
              zzvar5     TYPE     zd_var05,
              zzvar6     TYPE     zd_var06,
              zzvar7     TYPE     zd_var07,
              zzvar8     TYPE     zd_var08,
              zzvar9     TYPE     zd_var09,
              zzvar10     TYPE     zd_var10,
              zzvar11     TYPE     zd_var09,
              zzunit1     TYPE     zd_unit01,
              zzunit2     TYPE     zd_unit02,
              zzunit3     TYPE     zd_unit03,
              zzunit4     TYPE     zd_unit04,
              zzunit5     TYPE     zd_unit05,
              zzunit6     TYPE     zd_unit06,
              zzunit7     TYPE     zd_unit07,
              zzunit8     TYPE     zd_unit08,
              zzunit9     TYPE     zd_unit09,
              zzunit10     TYPE     zd_unit10,
              zzunit11     TYPE     zd_unit11,
              zztpemsnar1 TYPE     zd_tpemsnar,     
              zzrprtngyr1 TYPE     zd_rprtngyr,     
              zznonatar1       TYPE zd_nonatr,
              zzzcat1       TYPE zd_zcat,
              zzslitemar1  TYPE zd_slitemar,
              zzbnftyrs1        TYPE zd_bnftyrs,
              zzdescfrml   TYPE zd_descfrml,
             ZZFORMULA        type ZD_FRMLUSD,
            END OF t_prps.
      DATA: BEGIN OF t_emfactor OCCURS 0,
              naindex     TYPE     zd_index,     
              nayear     TYPE     zd_year,     
              cofactor     TYPE     zd_cofac,     
              vocfactor     TYPE     zd_vofac,     
              noxfactor     TYPE     zd_nofac,     
              pmfactor     TYPE     zd_pmfac,     
            END OF t_emfactor.
      DATA: BEGIN OF t_slef OCCURS 0,
             slindex     TYPE     zd_index,     
             slyear     TYPE     zd_year,     
             sltldfact     TYPE     zd_sltldfact,     
            END OF t_slef.
    Initialization mode (first call by SAPI) or data transfer mode
    (following calls) ?
      IF i_initflag = sbiwa_c_flag_on.
    Check DataSource validity
        CASE i_dsource.
          WHEN 'ZZODS_DATA_TRANS'.
          WHEN OTHERS.
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    Fill parameter buffer for data extraction calls
        s_s_if-requnr    = i_requnr.
        s_s_if-dsource   = i_dsource.
        s_s_if-maxsize   = i_maxsize.
      ELSE.                 "Initialization mode or data extraction ?
    Data transfer: First Call to pupulate data
    First data package
        IF s_counter_datapakid = 0.
    Extract data from prps for Project Types 15 and 17
          SELECT posid psphi zzdflt1 zzdflt2 zzdflt3
                 zzdflt4 zzdflt5 zzdflt6 zzdflt7
                 zzdflt8 zzdflt9 zzdflt10 zzdflt11
                 zzvar1 zzvar2 zzvar3 zzvar4 zzvar5
                 zzvar6 zzvar7 zzvar8 zzvar9 zzvar10
                 zzvar11 zzunit1 zzunit2 zzunit3 zzunit4
                 zzunit5 zzunit6 zzunit7 zzunit8
                 zzunit9 zzunit10 zzunit11
                 zztpemsnar1 zzrprtngyr1
                 zznonatar1 zzzcat1 zzslitemar1
                 zzbnftyrs1 zzdescfrml
           FROM prps
           INTO TABLE t_prps
           WHERE prart = '15' OR prart = '17'.
    Check for fetched records
          IF sy-subrc EQ 0.
            SORT t_prps BY posid.
          ENDIF.
    If the above condition is true
          IF NOT t_prps[] IS INITIAL.
    Get the data from z_fact
    Data : t_prps1 like t_prps occurs 0 with header line.
            SELECT naindex
                   nayear
                   cofactor
                   vocfactor
                   noxfactor
                   pmfactor
             INTO TABLE t_emfactor
              FROM z_fact.
    *RR          WHERE naindex = t_prps-zztpemsnar1+0(3)
    *RR           WHERE naindex = l_prps_index
    *GP        WHERE naindex = '01' or NAINDEX = '03'.
             AND  nayear  = t_prps-zzrprtngyr1.
    Sort the data by index and construction year
            IF sy-subrc EQ 0.
              SORT t_emfactor BY naindex nayear.
            ENDIF.
    Get the data from ztp_slef
            SELECT slindex
                   slyear
                   sltldfact
              INTO TABLE t_slef
               FROM ztp_slef.
    *RR           WHERE slindex = t_prps-zztpemsnar1+0(3)
    *GP        WHERE slindex = '01' or slindex = '03'.
    *RR           AND  slyear  = t_prps-zzrprtngyr1.
            IF sy-subrc EQ 0.
              SORT t_slef BY slindex slyear.
            ENDIF.
          ENDIF.
    Between this LOOP and ENDLOOP get the internal value of each project.
    Get the required data stored in above internal tables and populate
    the extract internal table
          LOOP AT t_prps.
            CLEAR l_output.
            CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT'
              EXPORTING
                input  = t_prps-psphi
              IMPORTING
                output = l_output.
            t_zzods_extract-psphi  = l_output.
            CLEAR t_emfactor.
            READ TABLE t_emfactor WITH KEY NAINDEX = t_prps-zztpemsnar1+0(3)
                                           nayear  = t_prps-zzrprtngyr1
                                           BINARY SEARCH.
            IF sy-subrc EQ 0.
              t_zzods_extract-cofactor  = t_emfactor-cofactor.
              t_zzods_extract-vocfactor =      t_emfactor-vocfactor.
              t_zzods_extract-noxfactor =      t_emfactor-noxfactor.
              t_zzods_extract-pmfactor  =     t_emfactor-pmfactor.
            ENDIF.
            CLEAR t_slef.
            READ TABLE t_slef WITH KEY     slindex = t_prps-ZZSLITEMAR1+0(3)
                                           slyear  = t_prps-zzrprtngyr1
                                           BINARY SEARCH.
            IF sy-subrc EQ 0.
              t_zzods_extract-sltldfact =     t_slef-sltldfact.
            ELSE.
               t_zzods_extract-sltldfact = '0'.
            ENDIF.
            t_zzods_extract-posid    = t_prps-posid.
            t_zzods_extract-zzdflt1  = t_prps-zzdflt1.
            t_zzods_extract-zzdflt2  = t_prps-zzdflt2.
            t_zzods_extract-zzdflt3  = t_prps-zzdflt3.
            t_zzods_extract-zzdflt4  = t_prps-zzdflt4.
            t_zzods_extract-zzdflt5  = t_prps-zzdflt5.
            t_zzods_extract-zzdflt6  = t_prps-zzdflt6.
            t_zzods_extract-zzdflt7  = t_prps-zzdflt7.
            t_zzods_extract-zzdflt8  = t_prps-zzdflt8.
            t_zzods_extract-zzdflt9  = t_prps-zzdflt9.
            t_zzods_extract-zzdflt10 = t_prps-zzdflt10.
            t_zzods_extract-zzdflt11 = t_prps-zzdflt11.
            t_zzods_extract-zzvar1       = t_prps-zzvar1.
            t_zzods_extract-zzvar2       = t_prps-zzvar2.
            t_zzods_extract-zzvar3       = t_prps-zzvar3.
            t_zzods_extract-zzvar4       = t_prps-zzvar4.
            t_zzods_extract-zzvar5       = t_prps-zzvar5.
            t_zzods_extract-zzvar6       = t_prps-zzvar6.
            t_zzods_extract-zzvar7       = t_prps-zzvar7.
            t_zzods_extract-zzvar8       = t_prps-zzvar8.
            t_zzods_extract-zzvar9       = t_prps-zzvar9.
            t_zzods_extract-zzvar10  = t_prps-zzvar10.
            t_zzods_extract-zzvar11  = t_prps-zzvar11.
            t_zzods_extract-zzunit1  = t_prps-zzunit1.
            t_zzods_extract-zzunit2  = t_prps-zzunit2.
            t_zzods_extract-zzunit3  = t_prps-zzunit3.
            t_zzods_extract-zzunit4  = t_prps-zzunit4.
            t_zzods_extract-zzunit5  = t_prps-zzunit5.
            t_zzods_extract-zzunit6  = t_prps-zzunit6.
            t_zzods_extract-zzunit7  = t_prps-zzunit7.
            t_zzods_extract-zzunit8  = t_prps-zzunit8.
            t_zzods_extract-zzunit9  = t_prps-zzunit9.
            t_zzods_extract-zzunit10 = t_prps-zzunit10.
            t_zzods_extract-zzunit11 = t_prps-zzunit11.
            t_zzods_extract-zznonatar1  = t_prps-zznonatar1.
            t_zzods_extract-zzzcat1  = t_prps-zzzcat1.
            t_zzods_extract-zztpemsnar1 = t_prps-zztpemsnar1.
            t_zzods_extract-zzslitemar1 = t_prps-zzslitemar1.
            t_zzods_extract-zzrprtngyr1 = t_prps-zzrprtngyr1.
            t_zzods_extract-zzbnftyrs1  = t_prps-zzbnftyrs1.
            t_zzods_extract-zzdescfrml   = t_prps-zzdescfrml.
           t_ZzODS_EXTRACT-ZZFORMULA   = t_prps-ZZFORMULA.
            APPEND t_zzods_extract.
            CLEAR t_zzods_extract.
          ENDLOOP.
    Delete the record before filling the custom Records
          CLEAR e_t_data.
          REFRESH e_t_data.
    Submit all the extracted records to extract table
          e_t_data[] = t_zzods_extract[].
          s_counter_datapakid = s_counter_datapakid + 1.
        else.
          Raise NO_MORE_DATA.
        ENDIF.
       s_counter_datapakid = s_counter_datapakid + 1.
      ENDIF.              "Initialization mode or data extractio
    ENDFUNCTION.