Getting default values in module pool screen
Hi frenz,
I have a requirement like in module pool i am supposed to bring 4 fields from ddic,in which the first two fields should have a default value i.e when the pbo is processed itself the input values should be displayed in first two fields.....can some one help me out to solve the issue.
thanks
prem
Edited by: prem kumar on Jun 19, 2008 1:30 PM
suppose u are using field1 field2 on screen...
then in PBO create a module
module def_val.
inside it write.
field1 = '100'.
field2 = '101'.
here 100 and 101 are the default values that u r going to assign....
that will solve ur issue..
rewrd points if the ans is helpful...
Similar Messages
-
Default values in module pool screen issue
Hello,
I have 6 input fields in one of my module pool tab-strip. I can able to populate default values in 4 fields, but 2 fields are not showing default value on the screen. I am passing these default value for all 6 fields in PBO module of that screen. My question is, why only these 2 fields are not showing default values on the screen?
Thanks,
ShreeEdgar,
Thanks for the reply, I checked again, the screen fields and variables name is exactly same.
Here is the sample code:
MODULE status_2050 OUTPUT.
gv_id_no_2050 = '200'.
gv_matnr_2050 = '232020191'.
gv_ebeln_2050 = '20019100'.
gv_qty_2050 = 3.
gv_bukrs_2050 = 'JP01'.
gv_comments_2050 = 'my comments here'.
ENDMODULE. -
Getting select options in module pool screen
hi experts,
can any one suggest me how to provide select options in module pool screen.
thank you,
regards
vijayHi,
Take two fields on screen first for low value and other for high value (say vbeln_low and vbeln_high) also design a button next to the high textbox for select-option button used to display popup.
Using these two input fields append a range (say r_vbeln for vbap-vbeln) for the field to be used (either in query or anywhere).
ranges : r_vbeln for vbap-vbeln.
IF NOT vbeln_high IS INITIAL.
IF NOT vbeln_low LE vbeln_high.
MESSAGE e899 WITH text-007. "high value is smaller than low value
ENDIF.
ENDIF.
r_vbeln-sign = 'I'.
r_vbeln-low = vbeln_low.
IF vbeln_high IS INITIAL.
r_vbeln-option = 'EQ'. "if user takes only a singlr value
ELSE.
r_vbeln-option = 'BT'. "if user takes both low & high value
r_vbeln-high = vbeln_high.
ENDIF.
APPEND r_vbeln. "append range
CLEAR r_vbeln.
On the button click call this FM to call a popup for select-options.
DATA : tab TYPE rstabfield.
tab-tablename = 'VBAP'.
tab-fieldname = 'VBELN'.
CALL FUNCTION 'COMPLEX_SELECTIONS_DIALOG'
EXPORTING
title = text-002
text = ' '
signed = 'X'
* lower_case = ' '
* no_interval_check = ' '
* just_display = ' '
* just_incl = ' '
* excluded_options =
* description =
* help_field =
* search_help =
tab_and_field = tab
TABLES
range = r_vbeln
EXCEPTIONS
no_range_tab = 1
cancelled = 2
internal_error = 3
invalid_fieldname = 4
OTHERS = 5.
IF sy-subrc EQ 2.
MESSAGE s899 WITH text-003. "no value selected
ELSEIF sy-subrc <> 0 AND sy-subrc <> 2.
MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
ENDIF.
This whole code will append your range r_vbeln to be used in program.
Hope this solves your problem.
Thanks & Regards,
Tarun Gambhir -
Hi all,
I am developing one module pool program.There are 2 screens in this object.In the first screen there are four fields.One of the field is order type.In this order type field i one to set FD as default value,so that when this screen comes up then FD will be in order type field.How I can do that?
Waiting for your response.
Thanks in advance.
RajHi,
Try it:
parameters: p_ordertype type ordertype default 'FD'.
Regards,
Chris Gu -
Module pool screen field should default without pressing enter
Hi
I have got a main module pool screen which has a tabstrip with four tabs.
There are 2 fields in the main screen when we select from F4 for the first field then the field 2 should default in case of a condition.
This happens only when i press enter. I want the second field to change as soon as the first field is selected.
How do I trigger the PAI as soon as the field 1 is selected.
eg: Field 1 : i/p
Field 2 : display
Field 3 : i/p
On F4 for field 1 say i select value 'A' then the valu for field 3 should default to value 'B'. Also field 2 should be displayed based on combination of field 1 and field 2. But now it does it only on pressing enter.
How do I solve this problem?Also if i select field 1 value A and dont press enter and go to the subscreen tab then it does not do any thing. It allows to go on the subscreen tab. But actually it should default the field 3 value. It does it only when I press enter.
Also the F4 is from dictionary that is the screen fields are from dictionary. I have not created any F4 for the fields.
Please help me solve this problem
Regards,
mozilaHi
You can achieve this using List Box only not by Input Field. Since Input field doesn't trigger automatic PAI/PBO
Go through the below thread
populate drop down menu based on entry in another field
or an alternative is--> In PBO use POPUP_GET_VALUES Fm to get the First input field based on that you can enter further values
unicode error
Cheerz
Ram -
Module-pool screen field value under POV event
Hi All,
I have one issue...please suggest me solution for this.
In module-pool program i have one screen(1000) which has one field(hrname_1000).
Under this event:
PROCESS ON VALUE-REQUEST.
FIELD hrname_1000 MODULE hrname_1000.
under this module hename_1000 i have used F4IF_INT_TABLE_VALUE_REQUEST to put a search help for field hrname_1000.
after that i am trying to retrive HR related stuff's based on the field on module-pool i.e i am using hrname_1000 in the where condition.
but problem is that im not getting value for hrname_1000 which im giving in the module-pool screen.
thats y my select query is not working.
Where as im getting values for the hrname_1000 under PBO & PAI.
It will look like below.
PROCESS ON VALUE-REQUEST.
FIELD hrname_1000 MODULE hrname_1000.
(under the above module)
SELECT DISTINCT ename plans FROM pa0001 INTO CORRESPONDING FIELDS OF TABLE itab WHERE stell = '50001026'.
LOOP AT itab INTO wa WHERE ename = hrname_1000.
ENDLOOP.
Please suggest
Thanks & regards
AnsumeshIn some of the cases the screen field is present in the screen but not holding the value in the required structure or field.
so here u need to check the option of reading the screen field values explictly..
//once u hit an enter and do the f4 i think the value will be there ...but if u dont hit enter and do an F4 the value cannot hold and i think u r in this case ..
1.Fill the screen field name in the structure dynpread.
DATA: BEGIN OF DYNP_VALUES OCCURS 10.
INCLUDE STRUCTURE DYNPREAD.
DATA: END OF DYNP_VALUES.
DYNP_VALUES-FIELDNAME = 'HRNAME_1000'.
APPEND DYNP_VALUES.
* read screen values
CALL FUNCTION 'DYNP_VALUES_READ'
EXPORTING
DYNAME = HELP_REPID "call the repid of ur prog
DYNUMB = HELP_DYNNR "pass the screen number
TABLES
DYNPFIELDS = DYNP_VALUES
EXCEPTIONS
OTHERS = 1.
now dynp_values hold the field name and field value of the screen .
now
SORT DYNP_VALUES BY FIELDNAME.
READ TABLE DYNP_VALUES WITH KEY 'HRNAME_1000' BINARY SEARCH.
IF SY-SUBRC EQ 0.
HELP_XXXX = DYNP_VALUES-FIELDVALUE. "store the value into a variable
TRANSLATE HELP_XXXX TO UPPER CASE.
ENDIF.
Now check the code with the value if its getting populated which once there will make ur select work ..
Vijay.. -
How to get the Grand Total in Module pool Screen
Hi Frds.
How to get the Grand Total in Module pool Screen
Example i have 10 different materials
for each matarial has different moving . But in my case matarials is doesnt matter here
10 material Moving Average price to do Frand total and display in one column...
Please Help me out Frds.
Regards,
KabilHi
You need to calculate the total in a module of PAI (or PBO) event:
PROCESS PAI.
LOOP.....
ENDLOOP.
MODULE CALCULATE_TOTAL.
MODULE CALCULATE_TOTAL.
GRAND_TOTAL = 0.
LOOP AT ITAB,
GRAND_TOTAL = GRAND_TOTAL + ITAB-PWB.
ENDLOOP.
ENDMODULE.
In this way the grand total will be calculated as soon as the user presses enter or another command.
You can't insert the calculation in the loop of table control, because this loop runs the visible lines only, so it's better to calculate the total out of those loop, -
Display Continuous Fluctuations in Input Data in Module Pool Screen
Dear All,
We are working on a Weighbridge Interface scenario, where the weighbridge is sending data to a digitizer, which is connected to the COM port of a PC. The objective is to read the data from the digitizer, and display in a Module pool screen. However, there is one more requirement: the weight may fluctuate until it stabilizes, and the fluctuations have to be displayed on screen. For example, the tare weight of a vehicle may be 12.4 TON, but when the vehicle is standing on the weighbridge, the weight may vary from 10.4 to 12.4 TON. The idea is to capture the stable weight, so that any discrepancies can be avoided. In the current IT system implementation, the fluctuations in the weight are displayed. But using ABAP, can these fluctuations be captured? For example, we may design a screen containing a field for capturing the weight, and the weight displayed there automatically refreshes as soon as there is a change in the digitizer reading. Is this possible to achieve? If so, how?
Awaiting answers.
Thanks and Regards,
SidHi Sid,
just a suggestion for the refreshing of an ABAP screen: you can use class CL_GUI_TIMER, but it only handles whole seconds, i.e. 1 second, 2 seconds and so on, but not 0.5 seconds...
An example of an ABAP listing could be the following:
*& Report ZZAVV001
REPORT zzavv001 NO STANDARD PAGE HEADING.
CONSTANTS: c_yes(1) TYPE c VALUE 'X'.
DATA: BEGIN OF t_bseg OCCURS 0.
INCLUDE STRUCTURE bseg.
DATA: END OF t_bseg.
data: d_num_bkpf type i,
d_num_bseg type i.
PARAMETERS: interval TYPE i DEFAULT 5. "meaning 5 seconds
* CLASS lcl_receiver DEFINITION
CLASS lcl_receiver DEFINITION.
PUBLIC SECTION.
METHODS:
handle_finished FOR EVENT finished OF cl_gui_timer.
ENDCLASS. "lcl_receiver DEFINITION
* Global data
DATA:
test TYPE i,
receiver TYPE REF TO lcl_receiver,
timer TYPE REF TO cl_gui_timer.
START-OF-SELECTION.
CREATE OBJECT timer.
CREATE OBJECT receiver.
SET HANDLER receiver->handle_finished FOR timer.
timer->interval = interval.
CALL METHOD timer->run.
PERFORM load_data. "or whatever you have to do to read the weight
PERFORM show_list. "or whatever you have to do to print the weight you've read
* CLASS lcl_receiver IMPLEMENTATION
CLASS lcl_receiver IMPLEMENTATION.
METHOD handle_finished.
PERFORM carga_datos.
PERFORM muestra_listado.
CALL METHOD timer->run.
ENDMETHOD. "handle_finished
ENDCLASS. "lcl_receiver IMPLEMENTATION
*& Form load_data
* text
FORM load_data.
clear: d_num_bkpf,
d_num_bseg.
select single count( * )
into d_num_bkpf
from bkpf.
select single count( * )
into d_num_bseg
from bseg.
ENDFORM. "load_data
*& Form show_list
* text
FORM show_list.
get time.
skip to line 1.
position 1.
write: / 'Date / Time:', sy-datum, sy-uzeit.
write: / 'Number of BKPF records:', d_num_bkpf.
write: / 'Number of BSEG records:', d_num_bseg.
ENDFORM. " show_list
Okay, it's just a tiny code snippet, but I hope it may help you by designing auto-refreshing screens.
Kind regards,
Alvaro -
Assigning 2 fields of same table in Module pool screen
Hi,
I want to assign similar fields of table in module pool screen.
In one case i directly use the tablename-fieldname and in other case when i try doing the same i get error. I know that this is not possible.
Is there any way to get around this. The field i am referring to is attached to a custom domain which is having defined fields. In the second assignment i need to retreive the values of the domain and display it in dropdown mode so that the users are able to select it.
Regards,
ImranThe domain only attached with this field?check the same domain attached to any other field and insert that field in the screen.
shibu
reward if helpful -
How to give ** bydefault in password in module pool screen .
Hi experts
how to give ******* by default in password in module pool screen .
ThanksHi ,
Double click on the field u will get a pop up window
i.e. attribute window for that field.
in that window you have a tab called Program at the bottom.
in program tab you have many checkboxes.
check the check box with name *Entry.
and activate.
what ever you enter now will be in password formate
Regards
Ajay -
How to get default values while using the transaction "BP"
Hi Group,
I have a query on how to get default values while using the transaction <b>BP</b>?
The thing is:
when I enter into the transaction "BP", I need to see some default values to some of the input fields in the screen.
how can I achieve this?
So please kindly let me know the procedure to achieve this.
Thanks & Regards,
Vishnu.Hi,
The events of BDT can be used to default some fields on creating a partner.
For this create a function module for ISDAT. attach that event in BUS7.
In the ISDAT funtion modulethe following code should be used.
For example to set the nationality:
I_BUSDEFAULT-NATIO = 'DE.
CALL FUNCTION 'BUP_BUPA_FIELDVALUES_SET'
EXPORTING
i_busdefault = I_BUSDEFAULT
Regards, Smita. -
Selct Options in Module Pool screen.......
Hi Gurus,
We know the way to get the Select options on the Module -Pool screen as follows....
Create 2 separate fields in your screen layout - one for the low value and one for the high value. Insert an icon beside the high value which will call the multiple selections popup screen on user command. Use function module COMPLEX_SELECTIONS_DIALOG to achieve this.
I have tried the same as a test run for the FM. .but not returning meaningfull range......
Can any 1 clerify where the code containing the FM has to be included in the Screen flow (inside PAI, PBO or else) to get the range which can further be used inside the code for database selections or else..... .
Secondly, how is the inserted icon populated and used while coding........????
Thanks And Regards,
Abhi........Hi
Please find the below code u will get select options
dont create any screen fitst jus type of prog is 'M' and create a tcode with 100 screen
than execute u will get select options
TABLES:VBAP.
SELECTION-SCREEN BEGIN OF SCREEN 100 .
SELECTION-SCREEN BEGIN OF BLOCK B1 WITH FRAME TITLE TEXT-001.
SELECT-OPTIONS S_VBELN FOR VBAP-VBELN.
PARAMETER P_WERKS LIKE VBAP-WERKS.
SELECT-OPTIONS S_ERDAT FOR VBAP-ERDAT.
SELECTION-SCREEN END OF BLOCK B1.
SELECTION-SCREEN END OF SCREEN 100.
Regards
Surendra -
How to create select-options on module pool screen
Hi all
I want get a range of values from the user from the module pool screen.
Is there any element available on module pool screen like select options on the selection screen of reports.
reply me ASAS.
Thanks.hi krishna
actually I want to display the details of PO numbers from 45000100 to 45000150. user will enter this range on the module pool screen just as we enter on the selection screen of report. My question is do we have a button like select-option on the module pool screen.
Plz . reply me ASAP.
Thanks. -
Variants for module pool screena
Hi,
I tried creating a variant for module pool screen by using the FM : RS_CREATE_VARIANT.
For this i created a dummy report which has the same parameters as the fields in the screen.
CALL FUNCTION 'RS_VARIANT_CONTENTS'
EXPORTING
report = gc_dummy_rep
variant = 'variant5'
MOVE_OR_WRITE = 'W'
NO_IMPORT = ' '
EXECUTE_DIRECT = ' '
IMPORTING
SP =
tables
L_PARAMS =
L_PARAMS_NONV =
L_SELOP =
L_SELOP_NONV =
valutab = lt_params
OBJECTS =
FREE_SELECTIONS_DESC =
FREE_SELECTIONS_VALUE =
EXCEPTIONS
VARIANT_NON_EXISTENT = 1
VARIANT_OBSOLETE = 2
OTHERS = 3
IF sy-subrc <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
but when i try to retrieve the values stored in the variant using FM : RS_VARIANT_CONTENTS.
CALL FUNCTION 'RS_VARIANT_CONTENTS'
EXPORTING
report = gc_dummy_rep
variant = 'variant5'
MOVE_OR_WRITE = 'W'
NO_IMPORT = ' '
EXECUTE_DIRECT = ' '
IMPORTING
SP =
tables
L_PARAMS =
L_PARAMS_NONV =
L_SELOP =
L_SELOP_NONV =
valutab = lt_params
OBJECTS =
FREE_SELECTIONS_DESC =
FREE_SELECTIONS_VALUE =
EXCEPTIONS
VARIANT_NON_EXISTENT = 1
VARIANT_OBSOLETE = 2
OTHERS = 3
IF sy-subrc <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
I get an error message : variant5 not found.
is there anything that i miss here?
or is the way i use to create variant for module pool screen not right?
Regards,
KaminiHi,
To avail save variant option in module pool screen,
1. You need to create a data base table similar to INDX table with the fields RELID, VARI_NAME
PROG_NAME
UNAME
SRTF2, MEMORYID, CLUSTR, CLUSID. And the remaining fields can be anything.
2. Enable the Save button in the Function keys part of GUI Status. And Add a push button for Get variant.
3. When Save button clicked call a screen with a single field for variant (let us say g_var). After g_var entered, in the PAI of the initial screen export all the screen values to the created database index using the statement .
EXPORT: g_characteristics_tab TO DATABASE zav0257(ch) ID g_var,
s_auart TO DATABASE zav0257(au) ID g_var.
So that the values will be exported to database.
Then update the fields(VARI_NAME,PROG_NAME,UNAME) of the database table using modify from work area.
So that you will have the history of variance existence.
4. Next time , when the user clicks on Get Variant option, call another screen to enter the variant name. Then import the values for that variant from the memory id in the database table.
It worked for me. -
Select-option field on module pool screen
hi all,
Can anyone pls let me know, how to design and use a field like a select-option field on a Module-pool screen i.e. how can i get that multiple selections tab after the high field of the select-options.
thanks in advance,
vinnyAll you need to do is define your selection screen and then embed it in a subscreen area of your dynpro(screen). Here is a sample program.
report zrich_0006 .
tables: mara.
* Custom Selection Screen 1010
<b>selection-screen begin of screen 1010 as subscreen.</b>
selection-screen begin of block b1 with frame title text-001.
parameters: p_rad1 radiobutton group grp1 default 'X',
p_rad2 radiobutton group grp1,
p_rad3 radiobutton group grp1.
select-options: s_matnr for mara-matnr,
s_matkl for mara-matkl,
s_mtart for mara-mtart.
selection-screen end of block b1.
selection-screen end of screen 1010.
start-of-selection.
call screen 100.
*& Module STATUS_0100 OUTPUT
module status_0100 output.
* SET PF-STATUS 'xxxxxxxx'.
* SET TITLEBAR 'xxx'.
endmodule.
*& Module USER_COMMAND_0100 INPUT
module user_command_0100 input.
endmodule.
<b>* Screen screen 100 with a subscreen area called "subscreen_1010"
* Screen Flow Logic follows
*process before output.
* module status_0100.
* call subscreen subscreen_1010 including sy-repid '1010'.
*process after input.
* call subscreen subscreen_1010 .
* module user_command_0100.</b>
Regards,
Rich Heilman
Maybe you are looking for
-
All and all I've spent 10 long days contacting ,calling ,chatting,and at the Genius Desk.When all Apple has to do is correct the mistake they consolidate all these account under my original account ,the e-mail ,credit card ,user name or all the same
-
Dear all I have V240 which is not comming up. By feeding the server we get the green led on the feeding, but then, when we push the starting buttom or we make the poweron control from the sc menu, the led becomes green and it is nomore possible to ac
-
ITunes won't open on my computer...
Running Windows 7. Have been using iTunes without issue for quite some time but it has decided to cease functioning for the past few days. It will open on OCCASION after initial startup of my computer but typically locks up and I'm forced to end proc
-
Transfer? iPod - iTunes on XP
Is there a reason my iPod music won't go to iTunes? I have some songs from another computer of mine that I want on this one, but my iPod won't transfer them...
-
jAOLT allows you to create and organise auctions for eBay and AuVito offline. I would use it as a eBay Turbo Lister replacement. Here's my incomplete PKGBUILD (my first attempt at one): # Contributor: Gladstone <[email protected]> pkgname=jaolt pkgve