GPIB readout from spectrum analyzer HP4195a

Does someone know how I can readout a HP 4195a spectrum analyzer with GPIB? I have a GPIB-USB cable. I can't readout the flopy disk from the spectrum analyzer in my PC.
Thanks, Ruben

Hi
I have a very old "generic" driver for this one
see attachment
greetings from the Netherlands
Attachments:
hp_network_analyzer.zip ‏408 KB

Similar Messages

  • Trying to acquire from Spectrum Analyzer CATV measurment​s.

    I am using an Agilent E4402B Spectrum Analyzer and can't seem to find any code that would help on the path of acquiring data from the Spectrum Analyzer. Need to acquire Carrier level and frequency, Depth of Modulation, and aural deviation. Currently using Techtronix Spectrum Analyzer and CSS 500 software with GPIB interface. Techtronix no longer makes the software and the scope I am using is not supported any longer for calibration or repair.

    Just have to go to the Instrument Driver Network and download it. An IVI driver is available here.

  • Obtaining Screenshot from Spectrum Analyzer - Not able to view the image created

    Hello,
    I am using the following code snippet in my program to get the screen shot from  Agilent Spectrum Analyzer , I am able to get a gif image created in the location specified but when i opened it I could not see any result.
    Please help out . I also tried with Interactive Utility still the same result , Am i missing something here or is there anything for me understand . please let me know.
    ibwrt(DeviceHandle,":MMEMTORCR 'CICTURE.GIF'",30);
    ibwrt(DeviceHandle,":MMEMATA? 'CICTURE.GIF'",28);
    ibrdf(DeviceHandle,"C:\\PICTURE.GIF");
    Thanks
    Meeran

    Dear Bala,
    I have got about 8 to 10 DC's out of which only this one is showing the missing structure and as this dc is being used by other dc's I am getting the error like missing component.  Previously we were using the client desktop and doin the work now we have shifted it to our individual systems.  Now any project I am creating whether from same track or different same problem comming the structure is missing.
    Regards,
    Ganesh
    Edited by: Ganesh Sawant on Sep 8, 2009 9:42 AM

  • Intermittant response from spectrum analyzer

    I have LabVIEW 8.2, NI 488 v.52. I am having problems talking to an old HP 8568A spectrum analyzer. 
    I can write to it OK, but reads are intermittant. 
    It takes a carriage return on the end of commands. On some reads, the response is fine using VISA in LabVIEW or using the NI-488.2 communicator, but on other reads, I get a timeout error EABO.
    The funny thing is, the response is actually there from the analyzer...It's like VISA or LabVIEW isn't seeing the response every time.  And this happnes with every command written to the analyzer that generates a response..
    Here is the NI-SPY capture where the first read went perfectly:
    2.  ibrd(UD0, "-13.50..", 2000 (0x7D0))
    Process ID: 0x000008A8         Thread ID: 0x00000F1C
    Start Time: 22:10:05.664       Call Duration 00:00:00.010
    ibsta: 0x2900       iberr: 0             ibcntl: 8(0x8)
    Here is another where the read timed out, but the correct response was actually read:
    >8.  ibrd(UD0, "-13.50..", 2000 (0x7D0))
    >Process ID: 0x000008A8         Thread ID: 0x00000F1C
    >Start Time: 22:11:41.672       Call Duration 00:00:16.774
    >ibsta: 0xc900       iberr: 6             ibcntl: 8(0x8)
    Thanks in advance for your time and help.
    Viv

    ALSO:
    I forgot to mention that we ended up with the HP8568A having to specify the to specify the number of characters that were read on each read request in the VISA Read VI due to the 8586A’s not sending an EOI.
    The read request would time out if we requested the read to end on an EOS character. 
    Viv

  • How to write data which i am reading from spectrum in excel using Report Generation toolkit.

    Hello All,
     I wrote code for reading data from Spectrum analyzer and also for writing in excel using report generation toolkit. When i run program values get read and excel sheet opens also but i cant see anything written in it.
    So if anyone can help me in this i will be very gald. I am attaching screenshot of my program and also attaching .vi file. As i am using drivers you can see some of vi.
    Thanking You,
    Pallavi 
    Solved!
    Go to Solution.
    Attachments:
    Channel_Power.jpg ‏123 KB
    Channel Power_Toolkit.vi ‏64 KB

    Hi Palavi,
    you try to select a specific worksheet what is not existing, therefore just select "Channel Power" (and not Power Channel) and it should work for you.
    Regards,
    Tobias

  • Communications between LabVIEW and spectrum analyzer

    hi, im a beginner in LabVIEW and spectrum analyzer, and im now trying to let LabVIEW captures signal coming from spectrum analyzer. i have all the required components needed but i have totally no idea how to get started, is there any exercises or labs available here?

    It will depend on your method of communication with the device.  If it is RS232 you can go to the example finder (Help > Find Examples) and search for RS232 or however you plan on communicating with the device.  Or you can browse the catagories for examples on various topics. 
    Depending on the device the manufacturer may have LabVIEW drivers on their web site.  But anybody will need more information on the analyzer and the signals before you can be helped. 

  • Can I view spectrum analyzer (HP 8562A) output on LV signalExpress

    Hello guys ..
    Just wondering if I can get my graphs from spectrum analyzer on LV SignalExpress? Is there a special driver I should download?
    Thank you

    Hi,
    You can view your data from the HP 8562A in LabVIEW SignalExpress by creating a user-defined step.  This applies to any instrument not supported by the native SignalExpress steps.  To do this, you need to follow the Creating SignalExpress Plug-ins with LabVIEW DevZone.
    On a side note, National Instruments has developed some plug-ins, such that a few 3rd party instruments can be controlled through SignalExpress.  The plug-ins can be found on this KnowledgeBase.  Unfortunately, the HP 8562A is not one of the instruments on this list, nor could I locate a supported driver for the HP 8562A on ni.com/idnet.  To communicate with your device, you could use low-level VISA commands or utilize the Instrument Driver Development Wizard.
    Let me know if you have any more questions.
    Regards,
    Sara Lewandroski
    Applications Engineer | National Instruments
    http://www.ni.com/support

  • Spectrum analyzer gpib programming

    Hi 
    I am new in Labview, I am trying to program my spectrum analyzer(MS9710B) through GPIB in a way that I can get the graph same as thing I see on CRT screen of
    Spectrum anlyzer. Could you help me what is the first step to start my program?

    There is an driver from Anritsu. Go to the main Instrument Driver Network for general information on what a driver is and how to use one. Be sure to start learning LabVIEW first with the basic tutorial.

  • How to capture a .gif file from a spectrum analyzer and save the file in PC

    I want to capture a .gif file from a spectrum analyzer and save the file in PC, but I've got a problem when read data from the instrument. I'm not sure how to format the string got from the instrument , When I use "%s" or "%t" as the read string format the data got from the instrument is truncated.
    my code are as follows, could anyone tell me where i am wrong?
    char resultsArray[5000];
    viPrintf(hSpectrumInstr, ":MMEMTORCR 'CICTURE.GIF'\n");
     viQueryf(hSpectrumInstr, ":MMEMATA? 'CICTURE.GIF'\n", "%t", resultsArray);
     printf("%s", resultsArray);
     getchar();       
    Solved!
    Go to Solution.
    Attachments:
    readResult.docx ‏50 KB

    char resultsArray[5000];
    viPrintf(hSpectrumInstr, ":MMEMTORCR 'CICTURE.GIF'\n");
    viQueryf(hSpectrumInstr, ":MMEMATA? 'CICTURE.GIF'\n", "%b", resultsArray);

  • Spectrum Analyzer GPIB Record and Save to AVI, MPEG, or MP4 file

    My objective is to record a waveform using labview and save it as an AVI, MPEG, or MP4 file to be able to replay it back at a later time.
    I would like to know if it is possible to capture a waveform for 30 to 60 second and save it as an movie format file.
    I have Labview 2013 version, Spectrum Analyzer N9010A and GPIB-USB-HS.

    Start by looking for the LabVIEW driver for your instrument. There may be something in there for capturing your waveform.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions

  • Where can I download a LabVIEW GPIB driver for an ANDO AQ6315E Optical Spectrum Analyzer?

    Where can I download a LabVIEW GPIB driver for an ANDO AQ6315E Optical Spectrum Analyzer?
    Thanks.
    Solved!
    Go to Solution.

    The Instrument Driver Network has all the drivers for instruments. There is no driver specific to that model, but there is one for the 6310B. Perhaps that may work for you. You may need to modify it. If not, you will need to write one yourself. You can get a lot of material for this here: http://www.ni.com/devzone/idnet/development.htm

  • Digits truncated in GPIB read with HP 8593 spectrum analyzer

    When I read the information from the HP spectrum analyzer, only the first digit is read .
    It works fine with other instruments

    Can you provide some sample code of what you are doing?
    What instruments does it work for?
    By digit do you mean one bit, one byte, or one reading?
    Were you expecting one reading or an array of readings?
    [email protected]

  • How to read the data in spectrum analyzer (Anritsu MS2661C) and put it in Excel using Labview

    Hi all, I'm new to using the labview, and I have some trouble doing my project using the labview software.
    I have been trying to use the spectrum analyzer (Anritsu MS2661C) which connect to computer using the GPIB connection.
    I have got the instrument driver which can write and control the instrument using Labview 2010.
    and my Question is how do read the data or result from the spectrum analyzer and send it to the microsoft excel?
    Do I need to use other software or programming to do this step?
    If anyone know how is this done, please let me know.
    Regards,
    Ery

    Hi ery,
    In order to send data that you have read in from an instrument to Excel, the most convenient way to do this would be to use our Report Generation Toolkit.  The Report Generation Toolkit is a very useful tool that allows you to interface to Microsoft Office software from LabVIEW, including Word and Excel.  I am not sure if you are familiar with this, but I have attached a link that explains more about the Report Generation Toolkit below.  
    Another way would be to use the Write To Spreadsheet File VI.  While this will store your data to a spreadsheet data file, it will not allow you to programmatically perform any Excel formatting like the Report Generation Toolkit offers.  I have also attached a link to some information on the Write To Spreadsheet VI below.  
    Also, be sure to check out the Example Finder in LabVIEW for a number of examples on how to write data to a spreadsheet file.  From LabVIEW, you can go to Help»Find Examples to launch the Example Finder.  From there, you can search for "spreadsheet," which should populate examples for use in different applications.  I hope this helps, ery.  Please let me know if you have any further questions about these!
    NI LabVIEW Report Generation Toolkit for Microsoft Office
    Write To Spreadsheet File VI 
    Taylor G.
    Product Support Engineer
    National Instruments
    www.ni.com/support

  • Agilent ESA Series Spectrum Analyzer (E4448A) - Can not initialize.

    I have downloaded the drivers for the Agilent ESA series Spectrum Analyzers from NI and I am having trouble just running the initialization VI.
    I am currently trying to run the VI called: agesa initialize With Options.vi on Labview 7.0 Express
    This is the error I receive:
    agesa Initialize With Options.viDriver Status: (Hex 0xBFFF0015) Primary Error: (Hex 0xBFFF0015) Timeout expired before operation completed.
    It looks like the Spectrum Analyzer does do a few things (Changes Carrier Frequency to 50 MHz), but it's getting hung up somewhere else.
    If I highlight execution, the error comes out of the Call Library Function Node elaboration output in the aforementioned VI.
    Here are the settings of the VI I have:
    Settings:
    id query: true
    reset device: false
    Option string: Simulate=0,RangCheck=1,QueryInstrStats=2,Cache=1 (The default)
    Resource Name: GPIB0::16:INSTR
    Any help anyone could provide would be appreciated. Keep in mind, I am fairly new at this. Thanks.
    From NI Spy (Numbers 20 and 22 with the ">" are the error lines):
    Note: This post can only be 5000 characters, so I have deleted a few of the steps:
    7. viWrite (0x001D6008, "*IDN?", 5, NULL)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.822 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    8. viRead (0x001D6008, "Agilent Technologies,...", 511, 50)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.822 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    9. viWrite (0x001D6008, "YSTPT?", 10, NULL)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.822 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    10. viRead (0x001D6008, ""226".", 512, 6)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.822 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    11. viPrintf (0x001D6008, "%s?")
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    12. Formatted viWrite (0x001D6008, "*IDN?", 5, 5)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    13. viRead (0x001D6008, "Agilent Technologies,...", 512, 50)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    14. viPrintf (0x001D6008, "*CLS;*ESE 1;*SRE 32")
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    15. Formatted viWrite (0x001D6008, "*CLS;*ESE 1;*SRE 32", 19, 19)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    16. viPrintf (0x001D6008, ":CALC:LLIN:CMOD FIX")
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    17. Formatted viWrite (0x001D6008, ":CALC:LLIN:CMOD FIX", 19, 19)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    18. viPrintf (0x001D6008, ":CALC:MARK:FCO:RES:AUTO %s")
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.010
    Status: 0 (VI_SUCCESS)
    19. Formatted viWrite (0x001D6008, ":CALC:MARK:FCO:RES:AU...", 26, 26)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.832 Call Duration: 00:00:00.010
    Status: 0 (VI_SUCCESS)
    > 20. viQueryf (0x001D6008, "%s?", "%hd")
    > Process ID: 0x00000388 Thread ID: 0x00000728
    > Start Time: 09:10:37.842 Call Duration: 00:00:17.085
    > Status: 0xBFFF0015 (VI_ERROR_TMO)
    21. Formatted viWrite (0x001D6008, ":BAND:RES:AUTO?", 15, 15)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:37.842 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    > 22. Formatted viRead (0x001D6008, "", 4000, 0)
    > Process ID: 0x00000388 Thread ID: 0x00000728
    > Start Time: 09:10:37.842 Call Duration: 00:00:17.085
    > Status: 0xBFFF0015 (VI_ERROR_TMO)
    23. viClose (0x001EC548)
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:54.927 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)
    24. viStatusDesc (0x00000000, 0xBFFF0015, "Timeout expired before oper...")
    Process ID: 0x00000388 Thread ID: 0x00000728
    Start Time: 09:10:54.927 Call Duration: 00:00:00.000
    Status: 0 (VI_SUCCESS)

    Well, I don't seem to have that option on the E4448A, here's what i do have:
    System -> Config I/O ->
    GPIB Address
    IP Address
    Host name
    Subnet Mask
    Gateway Address
    SCPI LAN
    Under System -> Config I/O -> SCPI LAN ->
    SCPI Telnet
    SCPI Socket
    SICL Server
    None of the above stuff seems applicable if I am only using GPIB?? I tried modifying some of the options above, didn't seem to help.
    Here's some more information in the Error History on the Spectrum Analyzer:
    -420, Query UNTERMINATED, &ltErr>
    -113, Undefined header, :BAND:&ltErr&gtRES:AUTO?
    The above looks like #21, and the error, #22, is right after it. Any idea what that means?
    I'm going to try it on another computer... More to come!

  • ADVANTEST 3131A SPECTRUM ANALYZER AND labVIEW

     Hello, 
     Trying to control R3131A spectrum analyzer connected through GPIB-USB-B and my laptop using Labview8.5. 
     I want to read frequency(Hz) from R3131A,and i want to send my measurments to an exel file ... 
     I have install the labview 8.5,the Measurment and Automation for finding my instrument and i have download the Advantest R3131A Drivers-libraries  from  that page  ....                    http://sine.ni.com/apps/utf8/niid_web_display.model_page?p_model_id=82   and then i install it in  Instrument I/O>Instrument Drivers palette.    I have read the examples code who coming with the drivers but i don't know which example  can help me...                                                                                                                                                                                                                                                                                                                                                                                      If someone knows something,or have an example code who doing that or other help,please send a message..                                                                                          thanks!..

    The typical way to make a measurement on any instrument is as follows:
    1.  setup the instrument for the measurement. 
    2.  carry out the measurement.
    3.  store result in a file
    1. In this case, you want to setup the instrument to carry out a frequency measurement.  Although I am not familiar with the Advantest SA, I'm sure it should be similar to the Agilent or Rohde & Schwarz SA.  So you first need to set the span wide enough to find the Center Frequency that you want to measure.  Then place a peak marker and set the center to the peak value.  You then narrow the span in order to improve your measurement.  Most likely adjust your resolution (BW) and place a peak marker.  You have now setup the instrument for the measurement.  The example should contain what you need to accomplish this.  Otherwise the user manual should give you the instructions on how to create the commands.
    2. You can read the values associated with the marker which will give you the frequency and amplitude.  There should be seperate instructions for these.  So you can read the frequency by itself.  There should be an example of this as it is a very basic measurement.
    3.  Storing the results... to Excel..  -sigh-  Most people refer to Excel, but end up needing to use a different function.  In any case, are you writing to an existing Excel Spreadsheet which already has information in it?  If not, you can use the "Write to Spreadsheet File.vi".
    R

Maybe you are looking for

  • How to find out which album(s) a photo is in?

    Apart from the right-mouse click and then "remove from album ...".

  • HP LaserJet CM1415fnw

    Every time I download the drive for the HP LaserJet CM1415fnw printer it says the file is corrupt.  Without having the driver I am unable to print.  Any help would be greatly appreciated. Thanks, Paul This question was solved. View Solution.

  • File content conversion 'lastFieldsOptional'

    Hi All, I am working on a File Sender content conversion--> flat file to XI. it's fixed length field all the rows with same column. 090627 344535AFDFG+GBP65433 ASDSSD GFD dFSSGFD     6757532 090627 344535AFDFG-GBP65433 ASDSSD GFD dFSSGFD     6757532

  • Lenovo G510

    Hi,I Bought Recently a Lenovo G510 (About  Weeks) When I Start Playing Games,The Left Side Of The laptop Become Hot And It Start Blowing Hot Air out Of It.(I Was Playing Call Of Duty 4) .is It A Hardware Failure Or What?Please Help Me

  • GATP implementation

    Hi, Is any one implementated GATP's - Product allocation, Rule based ATP only in GATP. APO is not linked with the SAP R/3?