Here's a general guide on how to select a PSU for your HP desktop.  The majority of standard ATX powersupply (PSU) should fit inside an HP case.  The exception would be a slim line case or the esoteric Blackbird. 
Look for an 80+ certification on the PSU to save electricity.  A PC will normally idle or run at low load 75% of the time.  Therefore, look for a PSU that's more efficient in the 50-90W range.  An 80+ 350W PSU reaches the 80% efficiency level at 70W output (20% of rated output).  The output must be greater than 140W to achieve the same level of efficiency from an equivalent 80+ 700W PSU.  So picking a PSU that is rated 25% higher than the maximum ACTUAL load of the rig will save you more $ on electricity. 
A modern PSU is designed to achieve peak efficiency between 20 and 80% of the rated output.  Running a PSU above the 80% load level will result in excessive heat, noise, and premature failure.
An Nvidia rig with GeForce GTX 280 (1024MB on board RAM) will draw about 350W max from the wall.  If we factor in the efficiency of a 80+ PSU, then the actual load on the PSU is only 280W (350 x 0.80).  To calculate the required PSU, multiply the actual load by 1.25 (25% margin).  In this case we only need a 350W PSU (280 x 1.25) to run this GPU.
Let's apply what we know to a Radeon HD 4870 (512MB on board RAM) rig.  290W max from the wall.  Actual load is 290W x 0.80 or 230W.  Now apply the 25% margin rule and we arrive at a PSU requirement of 290W (230W x 1.25).  Even if we apply a 50% safety margin, the power requirement is still under 350W (230W x 1.50).
There is no need to overspec the PSU by 50% unless you run your PC at full load 24/7.  Keep in mind that there is a huge variation in PSU quality and rating.  A cheap 500W PSU may not be able to deliver as much power as a quality 350W.  Antec Earthwatts/NeoPower/TruePower, Corsair, and Seasonic are quality units widely available at many US retailers.
Many high-end PSUs will need additional power from the PSU in the form of one or two 6/8 pin GPU power plug.  You can purchase an adaptor to convert a 4-pin molex to 6-pin GPU power plug.
http://www.tomshardware.com/reviews/geforce-radeon-power,2122-3.html
This question was solved.
View Solution.

Found a review of the Corsair 400W (Seasonic-built power supply) that I've been recommending on this forum.  This ATX power supply should fit inside most HP case (minus Slimline).  It has ample power to drive a modern quad core plus Radeon 4870 or GTX280 video card. 
At 100% load, we see a 2.5% drop in the +12VDC rail, which is still within spec and does not affect the performance of any component inside the PC.  +12VDC regulation at 82% load is a superb 0.5% with 45C case temperature.  Note that the power output and efficiency decrease with higher temperature. 
Cheap power supplies are rated at 25C.  When these units are subjected to higher case temperature, the output can drop 10-20%.
Again, we discover the sweet spot of a good PSU is 20-80%.  A good 400W PSU is more than adequate for many PC users.  This Corsair is only $30 after a $10 rebate.  That's a great price for a quality/quiet PSU that won't put a huge dent in your wallet.
http://enthusiast.hardocp.com/article.html?art=MTYwOSw1LCxoZW50aHVzaWFzdA==
http://www.newegg.com/Product/Product.aspx?Item=N82E16817139008&Tpk=corsair%20400w
Additional 20% off w/ promo code "Mar20", ends 3/31
Message Edited by RoyalSerpent on 03-08-2009 11:40 AM
Message Edited by RoyalSerpent on 03-08-2009 11:42 AM
Message Edited by RoyalSerpent on 03-08-2009 11:45 AM

Similar Messages

  • You are not authorized to display the panel for selecting a power plan

    I'm running Windows 7. Installed "Power Manager" via System Update 4.0 last night (10/23/2009). Getting this error when hitting FN+F3.
    You are not authorized to display the panel for selecting a power plan.
    Furthermore, I'm unable to see any of the default power schemes. Finally, I created two new power schemes, neither of them display for selection.
    Any one else experiencing this issue?!?!?

    Welcome to the forum!
    Hmm...  That seems odd.  Does the userid that you're using have admin rights to the machine?
    English Community   Deutsche Community   Comunidad en Español   Русскоязычное Сообщество
    Jane
    2015 X1 Carbon, ThinkPad Slate, T410s, X301, X200 Tablet, T60p, HP TouchPad, iPad Air 2, iPhone 5S, IdeaTab A2107A, Yoga Tablet, Yoga 3 Pro
    I am not a Lenovo Employee.
    I AM one of those crazy ThinkPad zealots!
    If you find a post helpful and it answers your question, please mark it as an "Accepted Solution"!

  • Looking for Apple TV power supply - any ideas?

    Hi folks,
    My out of warranty Apple TV has an obvious power supply problem (it's totally dead, no power up whatsoever).
    There are a few websites that have tutorials on replacing the power supply (or hard drive, etc...).
    The problem is I can't find a place to purchase a replacement power supply.
    It's a Delta Electronics ADP-36BF, Apple part # 614-0395 (http://s1.guide-images.ifixit.com/igi/HGslJDZeqPnKlFVD.huge)
    Any ideas on where to find one?
    If I can't get it myself to replace it, I'll probably just wait for the Boxee Box to replace it.
    Thanks.

    I'm in the exact same boat -- I've looked everywhere and can't find anything. I've even called Delta Electronics about the part and they said they can only sell them to Apple. If you find anything out please let me know! Thanks.

  • Looking for software driver for HP 6655A Power Supply with Labview 5.1

    Hi, trying to control an HP 6655a Power Supply but the version of Labview in the PC is the old Labview 5.1.
    I don't want to upgrade it for fear that the program will no longer function. Does anyone have the driver for the HP6655a that will work with labview 5.1?

    Hi demo,
    Try the drivers directly from Agilent.
    Here is a couple of links:
    http://we.home.agilent.com/cgi-bin/bvpub/agilent/editorial/cp_MiscEditorial.jsp?OID=536913992&NAV_ID=-536891584.536882066.03&LANGUAGE_CODE=eng&COUNTRY_CODE=ZZ
    Click on> Driver: 665xA Series Instrument Drivers
    Maybe this one is better... it's older...
    http://we.home.agilent.com/cgi-bin/bvpub/agilent/editorial/cp_MiscEditorial.jsp?OID=536917365&NAV_ID=-536891585.536880265.03&LANGUAGE_CODE=eng&COUNTRY_CODE=ZZ
    Click On > Driver: DC Power Supply Instrument Driver (1.13 MB)
    You may have to import the instrument driver after you install the libraries. This is done by selecting from the pull down menu:
    Tools > Instrumentation > Import CVI Instrument Driver
    JLV

  • Correct part number for G4 MDD power supply

    I am in the process of replacing my old Power Mac G4/350 with a G4 MDD 1.0 ghz DP.
    The power supply is missing from the MDD unit. Does anyone know what the correct
    part number for this power supply? 

    http://natramelec.com/g4powersupply/
    Part Number: 661-2816, 661-2816-R, 661-2725
    Manufacturer part: API1PC36
    Apple assembly: 614-0224, 614-0183
    Product EEE Code: NS3, P0V, P0W
    http://www.welovemacs.com/6612816r.html

  • SEARCHING FOR TUNSTEN E POWER SUPPLY REPLACEMENT

    I am working here in Baghdad, Iraq and need to know where to purchase a replacement AC adapter.
    Type is PalmOne  SAC MODEL R3W005-500
    PALM PIN:  163-5877A-US
    INPUT:  120VAC  60HZ  100MA
    OUTPUT:  5.5VDC 500MA
    ITE power supply    I think the power supply was plugged in to 220 by accident.  However, I do have a universal which works some but only charges at 4.5 volts. I would like to replace old one. But do not know where to go.  I am sure I will have to purchase online.
    Post relates to: Tungsten E

    Hello and thank you for using the Palm Help Forums!
    I was unable to locate a charger on our website but I was able to locate the charger you need on a different website. http://www.gethightech.com/Merchant2/merchant.mvc?Screen=PROD&Product_Code=CL-920&Category_Code=CC
    This is for the Tungsten E device you currently own. I hope this resolves your issue.
    -Pat

  • IMAC 27" goes black, won't run or boot up for hours. Power supply?

    and then suddenly be able to boot. But when you shut it back down, it won't boot again. Is this a power supply issue? I've cleaned it and tried multiple power outlets around my house, but the only cure seems to be to sit for a few hours. I use it with a Thunderbolt monitor on the side, but it doesn't seem to make any difference whether it's part of the equation or not.

    Hello ... I start to have the exactly same issue with my 21" after a shutdown or sleep mode ... ... I have to wait some time until I can boot again. If I try to boot after 5m or so I can ear the Hard drive and fans but it doesn't start (no screen, no startup sound or keyboard access). Any sugestion?
    Thanks in advanced,
    Jorge
    PS: I have already OS X 10.8.1 (12B19) version and this is a ( late 2009 iMac 21" 3.06 GHz Intel Core 2 Duo)

  • Labview drivers for sorensen dlm power supply

    I am looking for a LabVIEW driver for a Sorensen DLM 150-4 power supply.  I am using ethernet to communicate with it.  Can anyone help me?
    Thanks.

    Sorensen probably changed the firmware to more compliant with LXI specs. It's nice that they finally adopted SCPI but it's too bad they didn't maintain backward compatability to their older models. I wonder what they are telling their customers with an installed base of the GPIB instruments that might want to buy the new model. In theory, I suppose you could use the existing driver as a starting point and replace the old commands with the SCPI ones. I only have GPIB models so I can't be of much help there. Have you checked with Sorensen to see if they have a new driver? If you do create a new driver, please post it so others can benefit.

  • Want references for using ATX power supply with MDD.

    There are references all over the place to adapting an ATX power supply for a MDD/FW800. But it would be nice to have links to as many useful ones as possible in one thread -- this one -- without too much superfluous verbiage.
    Please post links with brief descriptive comments or, if you have some hard information that's not easily linked to, please post it as concisely as possible. Hopefully, the resulting thread will be useful to many people, and not just to me.

    Watch these great YouTube videos
    http://www.youtube.com/watch?v=xICg592xJTg
    http://www.youtube.com/watch?v=j7RDGy34tjU&feature=fvw
    Look at these links.
    http://efeion.blogspot.com/2007/12/power-supply-fun-part-2.html
    http://www.applefritter.com/node/23857
     Cheers, Tom

  • Workaround for bug (ACPI, Power supply)

    Hi.
    I'm using Arch on Samsung 530U and there is bug in handling with power supply. It is reported for example here: https://bugs.launchpad.net/bugs/971061, https://bugs.launchpad.net/bugs/1027798 etc.
    Samsung's replies on my urgents to fix it are: "Use windows..."
    In short - problem is that system remember if the battery is charging/discharging only at boot (I guess when acpi starts) and since than it is frozen. But the recognition of pluging/unpluging power supply works fine.
    Here is what is does, when cable was plugged at start:
    Battery is fully charged and adapter is connected:
    ~$ acpi -V
    Battery 0: Unknown, 80%
    Battery 0: design capacity 6100 mAh, last full capacity 6100 mAh = 100%
    Adapter 0: on-line
    ~$ cat /sys/class/power_supply/BAT1/status
    Unknown
    ~$ cat /sys/class/power_supply/ADP1/online
    1
    When the adapter is disconnected:
    Battery 0: Charging, 80%, charging at zero rate - will never fully charge.
    Battery 0: design capacity 6100 mAh, last full capacity 6100 mAh = 100%
    Adapter 0: off-line
    ~$ cat /sys/class/power_supply/BAT1/status
    Charging
    ~$ cat /sys/class/power_supply/ADP1/online
    0
    You can see that adapter is recognized well, but the battery still "thinks" it has been charging. I can't see how much time is remaining etc.
    When I manually try 'sudo echo "Discharging" >> /sys/class/power_supply/BAT1/status' I get permission denied.
    Any ideas or workaround?
    Thanks
    Last edited by Kotrfa (2013-04-16 08:38:10)

    Hi.
    I'm using Arch on Samsung 530U and there is bug in handling with power supply. It is reported for example here: https://bugs.launchpad.net/bugs/971061, https://bugs.launchpad.net/bugs/1027798 etc.
    Samsung's replies on my urgents to fix it are: "Use windows..."
    In short - problem is that system remember if the battery is charging/discharging only at boot (I guess when acpi starts) and since than it is frozen. But the recognition of pluging/unpluging power supply works fine.
    Here is what is does, when cable was plugged at start:
    Battery is fully charged and adapter is connected:
    ~$ acpi -V
    Battery 0: Unknown, 80%
    Battery 0: design capacity 6100 mAh, last full capacity 6100 mAh = 100%
    Adapter 0: on-line
    ~$ cat /sys/class/power_supply/BAT1/status
    Unknown
    ~$ cat /sys/class/power_supply/ADP1/online
    1
    When the adapter is disconnected:
    Battery 0: Charging, 80%, charging at zero rate - will never fully charge.
    Battery 0: design capacity 6100 mAh, last full capacity 6100 mAh = 100%
    Adapter 0: off-line
    ~$ cat /sys/class/power_supply/BAT1/status
    Charging
    ~$ cat /sys/class/power_supply/ADP1/online
    0
    You can see that adapter is recognized well, but the battery still "thinks" it has been charging. I can't see how much time is remaining etc.
    When I manually try 'sudo echo "Discharging" >> /sys/class/power_supply/BAT1/status' I get permission denied.
    Any ideas or workaround?
    Thanks
    Last edited by Kotrfa (2013-04-16 08:38:10)

  • VI for Walker Scientific Power Supply Control PSC 4

    I am inneed of the VI for the captioned instrument.  i have searched the instrument Drive in NI website and also tried to google it. I couldn't find. Is there anyone using the same and if so could you please let me know how to get the same?

    Hi Jayakumar,
    I just glanced through with the manual and I noticed that the instrument can be controlled with RS 232 (Serial) and IEEE 488 (GPIB). The command set is well documented, I do not think you need to make an instrument driverfor your device (if you are tight with time constraint). You can select one of the protocol RS 232 or IEEE 488 and try to create a program that suits your project/work. For a simple one, you can refer to the examples, (RS 232) Basic Serial Write and Read.vi and (IEEE 488) GPIB-VISA.vi, connect your instrument with either protocol and start sending the command set. If the simple test works, then you can develop more complicated program.
    PS: You can find the examples at NI Example Finder (Help>>Find Examples...) then Hardware Input and Output>>Serial and Hardware Input and Output>>GPIB.
    Hope that helps!
    Sincerely,
    Krisna Wisnu
    Message Edited by Krisna Wisnu on 12-05-2008 03:14 AM
    Sincerely,
    Krisna Wisnu

  • Anyone have a model or circuit for a switched power supply?

    Teach in a County College and would like to include this topic in one of the electronics courses.  Help is appreciated.
    Steve

    Thank you for your help Yi.  Im using 10.0.144.  Using the "Save As" function, I modified the circuit from the Averaged Model Current Mode boost to create the "Trial_Boost_CM" file.  (The path is "samples/SMPS Circuits/Average Analysis")  I've described the extent of my modifications with text on the schematic.  I've been able to successfully simulate it with several "unknown parameters" warnings in the audit log
    Using the same method, I created the "Trial_Buck_CM" file and modified it as noted on that schematic.  I've also been successful (with similar warning) simulating it.
    Finally, I created a third file, "Trial_MultipleConverter" from the "Trial_Boost_CM" via the "Save As" function.  I added a second sheet and pasted the circuit from the "Trial_Buck_CM". When this combined circuit is simulated, the error message "...duplicated subcircuit name ...." as I mentioned previously occurs.
    The error message does not appear when I delete either or both (naturally) of the CCM models.  Once I place the model again yields the same result. 
    This also occurs if you place the models within separate Hiearchial blocks.
    What am I doing wrong?
    Attachments:
    Trial_Boost_CM.ms10 ‏191 KB
    Trial_Buck_CM.ms10 ‏75 KB
    Trial_MultipleConverter.ms10 ‏288 KB

  • Where can I buy a replacement power supply (model VP-09500018-000) for my 1st generation Time Capsule?

    My 1st Time Capsule no longer powers on!  It was making noises for a while before it would no longer keep power / turn on!   I have taken the time capsule apart and could easily replace the power supply if I knew where to buy it   Can anyone lead me in the right direction?
    Thank you!

    Apple do not supply it as a part.
    You can repair the existing supply.
    https://sites.google.com/site/lapastenague/a-deconstruction-of-routers-and-modem s/apple-time-capsule-repair/apple-time-capsule-repair-type2
    Plenty of people sell the caps set on ebay. Cheaper if you have a good electronics store handy but they need to be top quality low esr capacitors.
    Substitute a different kind of power supply.
    I definitely believe in using external power supply for this job. This is my own website so disclaimer. 
    https://sites.google.com/site/lapastenague/time-capsule-power-supply-repair-kits
    Or some original type are available on ebay. Just search for "Time Capsule power supply"
    Or look at what a whole second hand TC will cost you.. a Gen3 or Gen4 can be a better proposition than repairing a dead Gen1.
    You can also do a half repair.. By that I mean you only need one voltage to run the TC.. a single 5v 3A power supply plugged into the TC board socket or soldered directly in.. will give you an airport extreme Gen2 for $10. Plug the hard drive in by USB.. or use a bit of careful hacking and use a SATA cable to the post on the board and use a 2TB or even 3TB esata case.
    You can also still buy a Cisco dual voltage supply on ebay.. but the wiring of it is a bit rough.
    https://sites.google.com/site/lapastenague/a-deconstruction-of-routers-and-modem s/apple-time-capsule-repair/cisco-adp-30rb-4pin-molex

  • Replacement product for redundant power supply RPS1000

    Hi,
    i would like to know what's the replacement product for RPS1000, i tried in cisco web page but no results.
    Please help me.
    Thanks

    Hello,
    Unfortunately there is no replacement product for the redundant power supply RPS1000.
    Regards,
    Cindy Toy
    Cisco Small Business
    Community Manager

  • Replacement power supply #614-0296 for iMac G5 20".

    Looking for a replacement power supply for an iMac G5 20", original part #614-0296. Model M9824LL/A.

    Try welovemacs.com or Jim Warholic

Maybe you are looking for

  • How to install Mac OS 9 on my MacBook Pro?

    I have recently bought a MacBook Pro. It came with the Mac OS X Tiger operating system. However, I need Classis environment for one of the programs that I wish to use so I went on and bought a new Mac OS 9 install CD, which I tried to install onto my

  • I paid for itunes match it keeps saying I havent paid for it?

    What am I doing wrong, I have the email saying that I have paid for it, but when I go to my Iphone to switch it on,it keeps saying You are not currently subrscribed to itunes match use itunes on your computer to subscribe?

  • How to download my icloud music to samsung tab s

    I have my music from my iPad  in the icloud but would like help in getting it on to my Samsung tab style Thank you for any advice you can give me. ...Dan

  • Need help setting up IMAP account

    I have an IMAP account with JustHost. I'm confused about how to set it up on the iPhone so that deleted and sent messages are stored on the server in the same folder they would be stored in if I deleted or sent them from Mail.app. JustHost include th

  • RFSG Peak vs Average Power

    I'm using a PXIe-5673E to generate multitone signals, and am currently adding the ability to pulse the output using script generation in RFSG. The problem is that when the 5673 is set to script, the power level type needs to be set to peak power. Eve