Help on function palet

I've installed lv6.1 and NI-DAQ 6.xx.xx; when I launch lv on the main window the DAQ wizard is not active can some1 tell me why? On the function palet i don't have the menu of Dat Aquisition why

This'll show you what to do:
http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/f7d5934af18eaa038625694600453df2?OpenDocument
2006 Ultimate LabVIEW G-eek.

Similar Messages

  • Image Processing and machine vision don't appear in Function Palette

    Hi,
    I have problem and I can't solve it
    Image Processing and machine vision don't appear in Function Palette, Although I set up NI imaq and NI Vision Acquisition Why??
    Anyone can help me?
    Solved!
    Go to Solution.

    If the image is already a Grayscale U8 image you would just have to save it to a bitmap file using the IMAQ WriteFile VI. If not, use the IMAQ Cast Image VI to convert it to a Grayscale U8 and then save it.
    Also, it would probably be better to create a new thread for questions like these.
    Cameron T
    Applications Engineer
    National Instruments

  • Populating the Signal Express Category on the Functions Palette

    Hi
    Can anybody help with advice on how to populate the signal express category on the block diagram Functions palette ?
    Thanks
    Solved!
    Go to Solution.
    Attachments:
    LV Functions Palette.PNG ‏14 KB

    Hi Ewan,
    Uninstalling and reinstalling in the right order would ensure that everything was properly associated. However, I don't think that should be necessary yet in your situation. Please go to Control Panel > Programs and Features > National Instruments Software to see the full list of National Instruments software you have installed. From here you should be able to select any individual installation from the list and select "Repair". Instead of just seeing that something is already installed and exiting, this should go through the installation and check for corruption. As well, this should add the correct associations if they were currently missed due to the order of installation. 
    Please try running a repair of SignalExpress 2013 and restarting your computer, then check to see if the functions palette in LabVIEW is fully populated.
    Thanks!
    Emily C
    Applications Engineer
    National Instruments

  • Vision Acquisition Software installed, BUT why is the IMAQdx missing from the function palette?

    I just installed to the labview 2011, and many other modules and softwares including this VASAugust2010. But the IMAQdx is missing from the function palette (vision and motion). However the NI-IMAQ 4.5, IN-IMAQ IO 2.4.0 and NI-IMAQdx 3.7 are all clearly listed as installed in the NI software (contorl panel -> program - NI). In MAX, my usb webcam is also listed as NI-IMAQdx Devices and works well under MAX. But my own program is broken because the LV can't find those functions. So why the IMAQdx funtion is missing and how to fix it?  
    Thanks,
    Lei

    hi tommy
    check this may helps you http://digital.ni.com/public.nsf/allkb/A451D3CCBB740716862578FC004DB392
    Sasi.
    Certified LabVIEW Associate Developer
    If you can DREAM it, You can DO it - Walt Disney

  • Where in the function palette can i find the "logical shift" function (shift x by y bits)?

    i am not able to find the "logical shift" function anywhere on the functions palette (after searching EVERY where). however, i discovered the function elsewhere in another VI (by pure luck!). i could keep bringing up these VI and copying and pasting, but that's a pain...i'd like to just have it on my functions palette to begin with.
    i am running labview 6.1 thanks for your help.

    hi,
    LabVIEW's functions pallete has come with a very useful tool --> "Search" tool
    Make use of the "Search" tool should you encounter difficulty in locating the desired function. For instants, search for keyword "Logical" or "Shift" and you will be able to locate the function
    happy coding
    Ian F
    Since LabVIEW 5.1... 7.1.1... 2009, 2010
    依恩与LabVIEW
    LVVILIB.blogspot.com

  • No DMM functions in functions palette

    Good Morning,
    I'm VERY new to labview but I'm starting to get the hang of it. Anyway i've been searching for hours and have been unable to find a solution to my issue.
    I'm running a NI PXIe-1078 chassis with PXIe-8101 controller 
    I'm trying to program data aquisition for my PXI-4071 DMM in my Labview project but there are no functions in the functions palette.
    I installed the NI-DMM 3.0.5 driver and can see the device connected in MAX. I can even use the soft panel and take measurements from the PXI-4071.
    For the other devices i have installing the driver put the functions in the functions palette but for some reason they are all missing for the DMM. 
    I've tried using the DAQmx and searching for an analog input channel but it is not on the list.
    please help!
    Sincerely,
    Michael Reed

    It sounds like a "corrupt" installation of NI DMM (see paragraph below).
    Please note that NI DMM 3.0.5 is out-dated, so you should get a more recent version.
    When installing a new system, NI recommends to start with the developement environments and in the last step to install all desired drivers. Following this ensures that the installer of the drivers can detect the installed ADEs and select to install the APIs for these. If you swap install order, the APIs are not installed with the driver, leaving the ADE blank (no examples, no palettes).
    You can install the APIs in a second iteration, but that is an effort you should only put into the system when installing a new version of an ADE.
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • "dir.mnu warning" after editing the function palette

    Hello everybody!
    I´ve got a small problem, which is getting on my nerves! I created a new subfolder with vi´s in the function-palette (with the advanced palette tool)... after all i deleted it, because now i use other vi´s. So the problem is everytime i open a vi of my project which has something to do with the "signal processing palette", i got this warning that the "dir.mnu" has changed.
    So far i created a new project, but the problem is still there... How can i restore the default palette settings? Can i delete the false dependencies? Or are there global files i can delete and then labview uses the default palette?
    Thanks,
    Michael
    Attachments:
    warning.JPG ‏28 KB

    I think when i installed Labview, there was a symbol for every VI in the function-palette. Could it be that i somehow have overwitten the defaults in the ...\National Instruments\LabVIEW 2009\menus folder? So thats why the "restore defaults" button is grayed out, because these ARE the default values. Is it possible to get the "dir.mnu" for the signal processing subpalette (...\National Instruments\LabVIEW 2009\menus\Categories\Signal Processing\dir.mnu) of somebody?... Reinstalltation is al little more complicated, because the DVDs are at our computer administrative department.
    So, thanks for your help....
    Michael
    Attachments:
    palette.JPG ‏37 KB

  • No PID controls in FUNCTION palette.

    I am using LabVIEW 8.6  I want to make use of the PID function but unable to find any such function in the FUNCTION palette of
    block-diagram. So please help me how can I get the PID function?

    The PID Toolkit does not ship with standalone LabVIEW.  It is an add-on you need to install and purchase.  Have you dome this?
    Kind Regards
    Lewis Gear CLD
    Check out my LabVIEW UAV

  • Modify function palette quickly?

    Hi, everyone
    I got a boring question when I modifying the function palette.
    Now I'm developing an instrument driver with LabVIEW7.0.
    I have an old version of its driver, so only I need to do is to update it, as the function palette.
    For example, the prefix of the old version driver is xyz2000, this time I should change it to xyz1000.
    But when I change the folder name to xyz1000(originally is xyz2000) and open the old version driver with LabVIEW,
    the function palette is full of [?]icon.
    Therefore I try to modify the following original xyz2000 mnu files with UE(text editor),
    I simply think if I replace all the [xyz2000] to [xyz1000] is just ok, but I failed.
    I got something like"memory is not enought" error.
    acstat.mnu
    applic.mnu
    config.mnu
    data.mnu
    dir.mnu
    util.mnu
    Does everyone have some ideas how to modify the function palette quickly in my case?
    Cause I think insert all the vis one by one again to function palette is a boring job ^o^, no easier way(just like modify the mnu file)?
    Help me plz, thank you

    This unfortunately doesn't apply to LV7.0, but there was a new feature in LV8.6 (it may have been in 8.5) for editing palettes much more quickly and easily. It was a VI-based set of functions for editing palettes. This would enable you to write a quick utility to manage your palette files and rename things more quickly and easily as you like.
    Message Edited by Jarrod S. on 12-29-2008 11:14 AM
    Jarrod S.
    National Instruments

  • Why i can not see the biomedical palette on the function palette when i run biomedical startup kit 8.5 on labview 8.6

    Hi. I am trying to install biomedical tools on my labview 8.6. when i run the biomedical startup kit 8.5, it installs correctly, but when i go to see if the biomedical palette exsists on the function palette i dont see it.
    can somebody help. 

    Howdy Boulos,
    I looked into this issue a little and found that you have also emailed into support.  I'm going to work with the engineer assigned to that request, but you can expect your primary source of information to come through email.
    The quick answer to your question is that the Biomedical Startup Kit you downloaded is for LabVIEW 8.5, while you have LabVIEW 8.6 installed. I'm checking to see if there is a way to port the VIs over manually into the LabVIEW 8.6 palette, but I'm not confident this will work at this point.  
    We will let you know through email what we find out, but the official answer at this point is that the program you've installed is not supported under LabVIEW 8.6.  Thanks, we'll keep you updated.  
    Sincerely,
    Chris G in AE

  • Functions Palette Broken

    I have LabVIEW 2012 Student Edition, Version 12.0f3 (32-bit), running on Windows 7 64-bit.
    When I click the "Initialize Array" icon on the functions palette, LabVIEW selects "Index Array" instead. How can I fix this?
    Here is a picture of the mouse hovering over the "Initialize Array" icon, and the Context Help displaying information on the "Index Array" function.

    I managed to solve the problem, although I'm entirely sure how.
    I think that when I installed a package it changed the available functions on the functions palette. Uninstalling the package seems to have fixed the problem.

  • "in port" and "out port" VIs are not in the functions palette!

    Hi,
    I am using LabVIEW 2012 on a Win 7 64 bit. I want to read a digital input (3.5V) using PC parallel port. I also read this white paper:
    http://digital.ni.com/public.nsf/allkb/B937AC4D8664E37886257206000551CB
    I searched all the functions palette for “in port” and “out port” VIs but I could not find them. Apparently they are not supported in 64bit OS. What are my alternatives for reading digital input via PC parallel port?
    Thanks.

    They have not been supported for quite some time. What happens when you use the recommended VISA api?

  • Assigning search help (F4 functionality ) for recipient field in IW32

    Hi,
    my requirement is to assign search help (F4 functionality) for recipient field in components tab of IW32. anybody help me to assign search help for it. same way i need to assign that in MIGO, MB21, MB1A goods recipient field.

    hi,
    refer to the following link:
    http://www.saptechies.com/how-to-add-f4-help-to-a-field-on-screen-module-pool/
    i hope it helps
    regards

  • In function palette-instrument I/O i have lost library:INSTR LIB

    when i clik on instrument I/O in the function palette, inside i have this library:GPIB,SERIAL,VISA,I/O COMPATIBILIY but i lost library INSTR LIB.
    In directory c:\programmi\national instrument\labview6\instr lib there are all my driver instrument
    haw can i view this driver in function palette\instrumet i/O ?

    Here is a great document that has instructions how to add a palette.
    How Do I Create a Custom Sub-Palette in the Functions Palette in LabVIEW 6i and Above?
    If this doesn't work, try reinstalling LabVIEW.
    Zvezdana S.

  • Function palette off screen

    My function palette was moved on to a secondary monitor. I no longer have that monitor and cannot see the functions palette. I've gone in to the labview.ini file (in the Program Files/National Instruments/Labview 2011 directory)  but cannot find an entry that sets the function palette position. I did see in another post  that there was supposed to be such an entry for the tool palette, but can't find that either) How can I get the function palette back on screen?

    Off-hand I'm not sure, but in the interim you can just right-click on the BD and pin the resulting palette.  I think the old one will still be off screen, but at least you'll have something to work with.
    Bill
    (Mid-Level minion.)
    My support system ensures that I don't look totally incompetent.
    Proud to say that I've progressed beyond knowing just enough to be dangerous. I now know enough to know that I have no clue about anything at all.

Maybe you are looking for