Hide front panel when running

Who knows the way to hide a VI's panel when VI is running?

Hi Ronin,
The reason that your Front Panel property node is no longer working is that the Current VI's Path VI is returning a different path for your executable than it did for your VI.  There is an excellent KnowledgeBase which describes this issue and how to work around it:  Functionality of Current VI's Path Depends Upon Execution Environment. 
By the way, in the future you will have much better luck getting replies if you create a new thread--this thread is three years old
Best Regards,
Megan B.
National Instruments

Similar Messages

  • Hide front panel when opened

    I have a VI running as a back ground task (VI_A) to the main VI (VI_B). VI_B starts VI_A and the idea is that VI_A will be minimised on startup. There is a button on VI_B to restore the window and a button on VI_A to hide the window and return to VI_B.
    This is all working OK, I open VI_A front panel when called, VI_B minimises VI_A straight away etc, I am using the WINUTIL.LLB functions to perform this. The problem I have is VI_A front panel is visible upon start up for a couple of seconds (there is no real delay in my execution to minimise). I have tried setting VI_A to be at teh back within VI_A but still it appears at the front for a couple of seconds.
    Does anyone have any suggestions as to why this is occuring.
    Cheers,
    Wayne

    One thing that you could do is to change the Windows Appearance property to NOT open front panel when called. You can then have your main VI (VI_B) open the panel for VI_A as before, but it will not start with the panel open. If you are creating an executable, go to the VI Settings tab page and click on the line with VI_A and then Edit Settings. Turn OFF the Remove Panel property. This should work for you (I've done similar already anyway).
    Rob

  • Hide front panel bars at open

    Good morning,
    Is there a way that I can hide the FP title bar and menu bar etc… at open? From the VI Properties, I can hide them at run time. But I would like to hide them at Open. I have a running main vi, it opens and runs another vi(code is attached). The main vi is run with full screen and hiding title, menu bar etc… I need to have the secondary vi run full screen without the bars as well. If I make changes in VI properties setting, the bars will disappear at run time, but I can see the bars flashing before they disappear. Any idea on how to accomplish this?  Thank you for your help and time! 
    Yonghe
    Solved!
    Go to Solution.
    Attachments:
    secondaryVI.doc ‏26 KB

    What I would do, if I'm understanding you correctly, is don't show the window when you call the VI (this can be set in VI properties; uncheck the box to show front panel when called). Then, in your code, set the windows properties using property nodes and after they are set programmatically show the window using a property/invoke node.
    CLA, LabVIEW Versions 2010-2013

  • Show LabVIEW VI Front Panel When Sequence Step Called

    Hello,
    By clicking on the “Show VI Front Panel When Called” checkbox in the Step Settings pane displays the LabVIEW VI Front Panel for approximately 100 milliseconds. Is there a configuration way to display the VI front panel for a longer period of time, during that step execution, and allow the user to control the duration of the front panel exposure by clicking to resume execution of the sequence file at their will?
    Thank you.
    Solved!
    Go to Solution.

    Hi,
    You will need to have some sort of structure in your VI for handling front panel response, otherwise you front panel is only going to be visible for as long as it takes to execute an return back to teststand.
    But remember, once you hold your step within that VI which is waiting on the operator to eventual close it, your Sequence will be held as well and if you are expecting steps to continue running after your VI then you will have to consider running it in parallel to your main test sequence.
    You may also need to consider what happens if you want to terminate your Test Sequence, how do you close your VI.
    Check out 'Strategies for Terminating or Breaking Sequences' in the following.
    hope this is of help
    Regards
    Ray Farmer

  • Looking for a way to programmatically set the visible portion of the front panel when a subVI opens

    I am looking for a way to programmatically set the visible portion of the front panel when a subVI opens.  Haven't found any posts that relate, but I'm not sure how to ask the right question.  To be clear, I want to write a helper VI to go through a list of subVIs to make sure the background images are all in the same place when their respective subVIs open.  I hate manually playing with scroll bars before I save each of the VIs...  I'm figuring I need to find the top/left location of the background image (know how to do this already) and then set a VI FP property to  these values or some offset, but I can't find the relevant property. FP:run-timeposition:custom looked promissing, but only affects the location of the window, not the area of the front panel the window is displaying.
    Solved!
    Go to Solution.

    Cool.  Getting closer.  The way I implemented your suggestion affects the subVI only if it is open.  I can use this to do what I'm after, perhaps putting the code into each subVI.  Maybe open all subs, run the helper, and save.    Seems like I'm missing the elegant version...
    My proof of concept code:

  • Disable launch of front panel when starting web services

    Hello all,
    This may be a naive question as it may have a simple answer that I am missing, but is there a way to not have all VIs associated with a web service launch (i.e. show their front panel) when you start a web service?  I find this to be very irritating as I have a lot of VIs associated with the web service that I am running and don't want my windows cluttered up with VI front panels that I am not interested in viewing.  
    Thanks, Matt
    Matt Richardson
    Certified LabVIEW Developer
    MSR Consulting, LLC

    Thanks for the reply, tst.  I was hoping that I would be able to reproduce this on the client side, but unfortunately I can't generate a simple example .  My web service is large and contains a lot of resources to access different variables and it seems to reproduce this, you would have to deploy this onto an RT target.
    Some further insight into the issue - starting a web service on my current target is similar to when you select Deploy All on a virtual folder in a project - all of the front panels become visible.
    Matt Richardson
    Certified LabVIEW Developer
    MSR Consulting, LLC

  • I created boolean references in my main vi block diagram and copied them to my sub vi front panel. when wire my reference in my main vi to one the input node of the sub vi the wire is broken. the error says its a class conflict why?

    i created boolean references in my main vi block diagram and copied them to my sub vi front panel. when wire my reference in my main vi to one the input node of the sub vi the wire is broken. the error says its a class conflict why?

    Expanding and clarifying what BJD said;
    After you create the temporary sub-VI that BJD mentioned, open its front panel and copy the reference control that LV created when it created the sub-VI.
    This reference control will be correct class etc that you need. Use the control to replace the original control that you were attempting to wire up.
    The technique of "create sub-VI...copy" always works for me.
    There is one more thing that you should watch out for.
    The mechanical action of the boolean can not be set for latch action when attempting to read the value using a value property node.
    Trying to help,
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • I want hide userid/pass when run forms app...

    i use sql*forms3.0 -_-;;;;
    i want hide userid/pass when run froms program.
    ex1) runforms30 fromname ( id/pass )
    ex2) runrep reportname ( id/pass )
    everyone show id/pass when this typing.
    "ps -ef | grep forms"
    Does someone knows if it is possible ?
    Thanks

    Though I did not use forms 3.0, you can try using on-logon trigger (if it exists in 3.0)
    At on-logon trigger write logon('username@connectstring', 'password'). Then mentioning (id/pass) is not required with runforms30. Check it out!

  • How to show the front panel when launching VI with Call by reference node??

    Hello!
    I just wonder how I make the front panel visible during execution when I launch the VI with CALL BY REFERENCE NODE.
    Se example.
    Could u also show me how to change different properties (window size ..) of the front panel??? (launched with CALL BY REFERENCE NODE)
    Thank you!
    Attachments:
    test.vi ‏18 KB

    In VI Properties>>Window Apperance>>Customize you can check "Show front panel when called". This will open the front panel on each call. It doesn't matter how the call was initiated.
    You can set a lot of Front panel properties during runtime. Place a Property Node in the block diagram. Change the class from App to VI. Under properties select Front Panel window>>Panel bounds to set the position and size of the front panel.
    Waldemar
    Using 7.1.1, 8.5.1, 8.6.1, 2009 on XP and RT
    Don't forget to give Kudos to good answers and/or questions

  • HIde Front panel - enjoy Ctrl-Key shortcut

    It is not a question, it is a link to a good old idea:
    http://forums.ni.com/t5/LabVIEW-Idea-Exchange/Allow-ONLY-the-Block-Diagram-to-be-opened-Without-Fron...
    and Ctrl-Key shortcut attached.
    Shortcut hides (including taskbar) and restores front panel window.
    It always activates block diagram after all:
    If you use shortcut with the hidden FP, it will activate block diagram (unlike simple Ctrl+E activates front panel)
    Attention! It will be hard to find VI, if you have hidden it's front panel and closed block diagram - that is why we still need this to be integrated into LabVIEW
    PS Use: Place into C:\Program Files\National Instruments\LabVIEW 2011\resource\dialog\QuickDrop\plugins and set shortcut in VI Shortcut window (Ctrl+Space -> Shortcuts -> Ctrl-Key Shortcuts)
    Attachments:
    Hide front panel.vi ‏19 KB

    It is a custom quick drop shortcut: Labview description is here:
    http://zone.ni.com/reference/en-XX/help/371361L-01/lvhowto/qd_keyboard_shortcuts/
    Place the vi to C:\Program Files\National Instruments\LabVIEW 2011\resource\dialog\QuickDrop\plugins
    Next time labview launches, it will be available, but you need to set a quick button for it:
    Press Ctrl+Space, it will open Quick drop window.
    Press Shortcuts..., switch to Ctrl key shortcuts tab (see picture)
    Set the button (E) for the selected plugin vi.
    Next time you press ctrl+space, followed by Ctrl+E, LabVIEW executes plugin vi.
    Correction for my description: if the front panel is hidden, closing block diagram closes the vi (with confirm dialog, as usual). This is not a problem
    Attachments:
    Untitled.png ‏28 KB

  • How can I hide the main front panel when I run from the executable?

    Hopefully this is an easy question. I have an application where the front panel is not the main GUI and I would like to hide it when the program runs, but only when it runs from the executable. How can I do this?

    NIquist wrote:
    Yeah, don't do that. Executables built in LV require at least one front panel to be open. If it isn't, the run-time engine automatically closes the executable. I haven't checked recently, but I assume this is still the case.
    Instead, you can set the FP state to minimized (as suggested earlier) or (better) to hidden.
    P.S. one side point - the property and invoke nodes have a shortcut - if you use the Application or VI classes and don't connect a reference, they default to the current app or VI. That means you don't have to open the reference.
    Try to take over the world!

  • Why do I get "error code 3: Could not load front panel" when I run my executable​.

    I have a LV 8.5 VI that controls only an agilent spectum analyzer. The agilent VIs call DLLs rather than SCPI commands. I created an application and an installer to load on a non LV machine and ran setup which was successful. When I run the EXE I get "error code 3: Could not load front panel" for each of my agilent spectrum analyzer VIs. I have to click "OK" about ten times, once for each VI. (My executable runs fine on all machines that have labview 8.5) The front panel does load with a broken arrow. The errors listed when the arrow is clicked for all of the Agilent VIs state: Missing subVI AGE444xInitialize.VI (or close.VI or read.VI etc.)
    There is an AGE444x32.DLL in the data folder with the EXE file so I included as support both the DLL and all of the agilent drivers in the application build. Still no luck. I have built the application and installer about 6 times in various forms. I NEED AIR SUPPORT.
    Unfortunately I do not have access to the internet at my jobsite so bear with me.
    Rob

    Hi V-rob,
    I'm glad to hear the executable is working now that NI-VISA is installed.  Thanks for posting the solution!
    Jennifer R.
    National Instruments
    Applications Engineer

  • How to see the full program on the front panel when it is running?

    Hi, my program is really big, and when I run it and obverserve the program on the front panel, I cannot drag the window to see the other parts. Also, I tried the method like hold control, then press + to zoom in or press - to zoom out. However, labview seems doesnt have this function. Does anyone know how I can see the full program then it is running, maybe zoom out or drag the windows? thanks! 
    Attachments:
    not running.png ‏85 KB
    running.png ‏72 KB

    You should use a Tab control.  Group your front panel objects together and put the grouped items in tabs.  Then you can select the Tab you want to display while the program is running.
    It is never a good idea to make your screen too big to fit on one display.  This goes for the block diagram also.  If you have to scroll to see it all, use more subvi's.  Make it modular.  A state machine is a good way to put a lot of code on one display screen.
    - tbob
    Inventor of the WORM Global

  • Is it possible to use a Case Structure to hide numeric indicators on the Front panel when they are not in use?

    I am rather new to LabVIEW, have only been using it for about 1.5 weeks as of this post, which means I may be missing something rather obvious due to ignorance, but is there any way to have my front panel change as my case changes due to user selection of a certain case via the front panel?
    The goal of the program is to make a simple layout for a user that is using the digital multimeter that the proposed code is designed for and I don't want tons of numeric controllers and such clogging up the screen space that don't work with the function the user is using to measure with.
    Thanks in advanced.
    Solved!
    Go to Solution.

    Check out the property node for the controls
    Visible Property
    Short Name: Visible
    Requires: Base Package
    Class: Control Properties
    Displays the front panel control.
    This property is similar to the Show Control and Hide Control options on the shortcut menu of a control.
    Also look at the TAB control to control which controls are available to your user.
    Omar

  • How to pop up another VI front panel and run this in the main VI?

    Hi all,
    I want to create a VI, which contain several buttons: like "RUN ANALYSIS 1" and "RUN ANALYSIS 2".
    When I click one of them, another front panel of VI jump out and run automatically. When I click on "Finish" button on this VI (the one jump out), this front panel close.
    How to complete it?
    Thanks,

    Hi Osso,
    The ability to click on other VIs is also controlled by the Window Appearance. If you follow Dennis' instructions above, but this time change the Window Behavior to modal.  You can find more information about the different selections in the LabVIEW Help: Customize Window Appearance Dialog Box.
    Regards,
    Elizabeth K. 
    National Instruments | Applications Engineer | www.ni.com/support 

Maybe you are looking for

  • Error while running isupplier portal from jdev after patches

    latest POS rollup patch was applied and since then i get an error on local machine while running portal pages, need not mention that my substitution has also broken after patches. On server : login as isupplier > click on any PO either on home page o

  • SD - Accounting document line items are generating for each item

    Hi all of you, We have done account determination for SD. Accounting documents are also generating, but with in the invoice accounting document, number of line items are generating for each item with in the sales order, standard invoice type is F2 li

  • Getting uploded file object from bea Content repository

    Hi, This is regarding bea portal 8.1 content repository I have a content node ,type of content is message or article Now in this one of the attribute is Attachment.. I have uploded a XMl file to this attribute How do i retrive this file object using

  • Me2o Purchase Order View

    Hello Folks! I am trying to implement subcontracting procedure in SAP. The Purchase order has been successfully created. The user wants to issue material from the warehouse. Before the standard the procedure the user was using MB1b to issue material.

  • Configuring startWebLogic.sh for Red Hat Linux 7.2

    I was successful in configuring and executing startWeblogic.cmd, but have not been so lucky getting the equivalent to run on Red Hat 7.2 using startWebLogic.sh. For starters, even before I began editing startWeblogic.sh and just tried running I recei