How many standby cm?

Hi,
currently i have two CM. A primary and a standby. As a requirement of a DRP site i have to deploy another standby CM. Is it possyble? there is any restriction on the number of standby CM?
thx
Rafaelgc

You can have many standby CMs, I think up to 8, but possibly even more then that. You should be fine with 2.
Thanks,
Dan

Similar Messages

  • Configuring data guard: how many standby redolog do I need?

    Hi all, I want to add a standby databse to my RAC test environment but I don't understanad how many redolog I need.
    The main db is a 2 node RAC (10.2.0.4.0); every node has 3 log groups; every log group has 2 logfile (every log group is multiplexed on DG_DATA1/ASR/ and FLASH_RECOVERY_AREA/ASR/ )
    The standby db will have all its datafile on the same filesystem, so I already configured the trasnslations parameters:
    DB_FILE_NAME_CONVERT='/opt/oracle/app/oracle/oradata1/ASRSB','+DG_DATA1/ASR','/opt/oracle/app/oracle/oradata2/ASRSB','+FLASH_RECOVERY_AREA/ASR'
    LOG_FILE_NAME_CONVERT='/opt/oracle/app/oracle/oradata1/ASRSB','+DG_DATA1/ASR','/opt/oracle/app/oracle/oradata2/ASRSB','+FLASH_RECOVERY_AREA/ASR'
    Replication via rman works well, but I have to manually add the standby redolog on the standby db and which formula to use to calculate the number of the standby redolog needed. Which is the correct formula between :
    1)
    # of standby log = ( # of redolog files + 1) * # of thread = (6 +1)*2 = 14 standby redolog files
    2)
    # of standby log = ( # of redolog groups + 1) * # of thread = (3 +1)*2 = 8 standby redolog files
    thanks,
    andrea

    Andrea,
    I think 8 should be the answer on your question. Because you have 3 log groups and 2 threads therefore (3+1)*2 = 8.
    According to the documentation :
    http://download.oracle.com/docs/cd/B19306_01/server.102/b14239/create_ps.htm#SBYDB00426
    Minimally, the configuration should have one more standby redo log file group than the number of online redo log file groups on the primary database. However, the recommended number of standby redo log file groups is dependent on the number of threads on the primary database. Use the following equation to determine an appropriate number of standby redo log file groups:
    (maximum number of logfiles for each thread + 1) * maximum number of threads
    I think you may get confused with maximum number of logfiles. But sometimes logfile is used as a synonym to log group. The actual log group files are usually called log members. (for instance MAXLOGFILES parameter specifies the maximum number of log groups and MAXLOGMEMBERS specifies the maximum number of members for each group).
    Each additional member in a redo log group is just a multiplexed copy. You can also consider multiplexing the standby redo log files, the same why you do for redo log members.
    In order to learn more about the usage, benefits and limitations of Standby Redo Logs (SRL) you can refer to Metalink Note 2193444.1.
    I hope this helps.
    --Mihajlo                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               

  • I dont know why the battery life of my iphone 4 is so low ! i really want to know how many hours i'll have if it's on standby. And how many hours if i use it normally for music and facebook (sometimes a little bit games)

    i dont know why the battery life of my iphone 4 is so low ! i really want to know how many hours i'll have if it's on standby. And how many hours if i use it normally for music and facebook (sometimes a little bit games) !!!

    to enhance your battery life, keep screen display to minimum, set screen lock automatically after 1 min, select internet notifications to off.

  • How many Hard Drives ?

    I've been fortunate to receive a PowerMac G4 733mhz (Digital Audio) along with a Sony 20" CRT monitor at no cost and I'm looking to get all the performance that I can out of it.
    So far I've maxed out the RAM and added an iogear USB 2.0 card along with a SIIG Utra ATA 133/100 Pro controller card. The Radeon 9800 pro video card is a couple weeks away yet.
    I now have a 160gb and a 60gb as master/slave on the main board, and another 160gb on the controller card in which I'm adding another 80gb to tonight.
    I am wondering how many hard drives I can add before I have to start worrying about the power supply. Keep in mind that I'm going to be adding the video card in the future.
    I also see that SIIG card says OSX 10.1 or later, does this mean that I cannot connect a drive that boots into OS 9 to the card? Or a drive that may have Yellow Dog Linux?
    Thanks, I'd appreciate any input about this new project of mine.

    Hi-
    OK, let's talk power.... This is what we have to work with (may be slightly higher depending on PSU model):
    DA 338W PSU
    +5V=20A
    +3.3V=24A
    +28V=4.04A
    +12V=8A
    -12V=0.25A
    Total on combined +3.3V and +5V =126W @32A
    Of course, there is a big difference between idle and load power consumption, but I will list maximum power consumption values. Various requirements are:
    ATA/100 Hard drive- Read/Write, approx. 12.8W [email protected], [email protected]
    Optical Drive- Full Speed (42x) read, approx. 5.6W [email protected], 15.7W [email protected]
    Memory (per 512mb DIMM) 1-3W combined 3.3V,+5V,[email protected]
    PCI and AGP slots combined max +3.3V, +5V=62W, AGP (only) up to 20W
    Firewire Bus 15W+25V
    USB Bus 5v@500mA per port
    733mhz PPC processor 1.6V 15.6W (Idle) 22.0W (load)
    Fans (combined) +12V [email protected]
    As for the Radeon 9800 Pro, under full load, the power requirements are:
    +5V [email protected]
    +12V [email protected]
    +3.3V(AGP) [email protected]
    +5V (AGP) [email protected]
    +12V (AGP) [email protected]
    Points to consider (no particular order):
    -An ATA hard drive at idle, will still pull 7.2W and at Standby, will pull 1.4W.
    -Unless you are running 2 RAID sets, you would rarely, if ever, have 4 drives simultaneously in Read/Write.
    -One process that will push a system to the max is disc burning. Consider CPU at load, one, possibly two hard drives at Read/Write load, and the Optical drive at load. (For all who care, this is why we don't multi-task during burning). Without multi-tasking, the graphics power draw is minimal.
    -Weak point of early ATX PSU revisions was the 12V rail. The G4 PSU also has a weak +12V rail (only 8A).
    (Run a dual internal RAID, and try to burn a disc..... well, you better set the machine up as a headless server.....)
    -Total combined +3.3V, +5V wattage and ampherage is sufficient for most fully loaded system and bus combinations.
    -The power requirements of the 9800 Pro are all within the maximum limits of the various voltage rails of the OEM PSU.
    -A 237W PSU equipped Sawtooth will run without problems with two hard drives (one system, one storage), a 2.0ghz 7447 processor, USB 2.0 PCI, Radeon 9800 Pro and AC VGA fan. Additional hard drive (scratch drive), PCI cards, HDD fans and lighting overload the +12v rail for operation at load with disc burning. (we're talking about real life experience here...)
    -Hard drives are heat producers, and an external firewire connected housing can allow for better overall system operation by reducing interior clutter and heat production.
    -High interior temperatures reduce the ability of the PSU to cool itself, and thereby reduce it's ability to produce reliable power under load, in the heat.
    -Old ATA hard drives are power hogs and hot in comparison to current SATA drives. Switching to two larger SATA drives will reduce load requirements by 3-4W per drive, as well as reduce heat production. Required use off a SATA PCI controller card eliminates the capacity restriction of the native ATA controller. Switching to SATA saves space, power, and cooling needs.
    -And, final (random) thought to consider, a dual 500mhz Gigabit Ethernet (same PSU as the DA) will run two ATA drives simultaneously, burn a DVD, with a 9800 Pro installed, without any problems whatsoever. The same machine will run 3D graphics intensive games at enjoyable framerates, without problem. Internet video, on line games, etc., are all enjoyable, with reasonable performance for the given CPU speed. All uses of the machine are without problem, with the added graphics benefit provided by the 9800 Pro (Yep, another real life experience).
    Now, you decide....

  • How many NWDI's in your SAP Landscape

    Hi SAPpers,
    we have a reasonable size SAP landscape and our developers do a lot of WebDynPro developments for Portal.
    We are now beginning to integrate CE with NWDI too, but that's a separate story.
    My point is, in our SAP Landscape we have ONE NWDI installed.
    We've just had basically a system down for NWDI for the last 10 days and it has shown us what a single point of failure NWDI is, because, as we have only one NWDI, if it is down, Developers cannot work, and transports cannot be completed.
    Therefore, my question,
    What does everyone else do about this ?
    Should we have a second NWDI, as a warm standby, where, if we lose the main NWDI we then configure the tracks in the standby NWDI and get the Developers to work against that one while we fix the primary NWDI ?
    Is there any guidance from SAP on how many NWDI's to have in a SAP Landscape to stop the NWDI becoming a single point of failure ?
    Others, please be aware of the risks and consequence of only one NWDI in a SAP Landscape.
    Thanks and regards,
    Petr.

    Hi Pascal,
    thank you for your reply.
    High availability of NWDI would not help the problem that recently happened to us, NWDI for various reasons stopped working.
    Hence we need to think about some kind of warm standby NWDI which could be bought up in emergencies, have all tracks configured in probably 12 hours - for ESS etc and then become active while the main NWDI is being repaired.
    NWDI is indeed a single point of failure on its own.
    Kind regards,
    Petr.

  • How many BTC's in SAP BI

    Hi All,
    I would like to know how many BTC's (Background child process) were running in the past (say yesterday or 2 days back at a particular time). Is there a way to find out in SAP BI system?
    Thanks in advance

    Hi Pascal,
    thank you for your reply.
    High availability of NWDI would not help the problem that recently happened to us, NWDI for various reasons stopped working.
    Hence we need to think about some kind of warm standby NWDI which could be bought up in emergencies, have all tracks configured in probably 12 hours - for ESS etc and then become active while the main NWDI is being repaired.
    NWDI is indeed a single point of failure on its own.
    Kind regards,
    Petr.

  • How many hours needed to charge the new iPad when connected to the wall outlet.

    How many hours needed to charge the new iPad wifi 16 gb?
    Yesterday it was my first time to charge and it takes around 8 hours (it was not on wifi& not on working any application)
    when connected to the wall power outlet using the supplied charger,dock and the USB wire.
    I,ll be waiting for urs reply.

    The quickest way (and really the only way) to charge your iPad is with the included 10W USB Power Adapter. iPad will also charge, although more slowly, when attached to a computer with a high-power USB port (many recent Mac computers) or with an iPhone Power Adapter (5W). When attached to a computer via a standard USB port (most PCs or older Mac computers) iPad will charge very slowly (but iPad indicates not charging). Make sure your computer is on while charging iPad via USB. If iPad is connected to a computer that’s turned off or is in sleep or standby mode, the iPad battery will continue to drain.
    Apple recommends that once a month you let the iPad fully discharge & then recharge to 100%.
    At this link http://www.tomshardware.com/reviews/galaxy-tab-android-tablet,3014-11.html , tests show that the iPad 2 battery (25 watt-hours) will charge to 90% in 3 hours 1 minute. It will charge to 100% in 4 hours 2 minutes. The new iPad has a larger capacity battery (42 watt-hours), so using the 10W charger will obviously take longer. If you are using your iPad while charging, it will take even longer. It's best to turn your new iPad OFF and charge over night. Also look at The iPad's charging challenge explained http://www.macworld.com/article/1150356/ipadcharging.html
    Also, if you have a 3rd generation iPad, look at
    Apple: iPad Battery Nothing to Get Charged Up About
    http://allthingsd.com/20120327/apple-ipad-battery-nothing-to-get-charged-up-abou t/
    Apple Explains New iPad's Continued Charging Beyond 100% Battery Level
    http://www.macrumors.com/2012/03/27/apple-explains-new-ipads-continued-charging- beyond-100-battery-level/
    New iPad Takes Much Longer to Charge Than iPad 2
    http://www.iphonehacks.com/2012/03/new-ipad-takes-much-longer-to-charge-than-ipa d-2.html
     Cheers, Tom

  • S750 - How many people get the power on/off/resetting issue?

    How many people get the power on/off/resetting issue?
    I've had my S750s for about 6 months, with X-Fi Elite Pro, and has been doing it since.
    Any idea on what's the cause? Something to do with the control pod?
    Thanks.

    Hi,
    What do you mean exactly? On my side I have power on/off/resetting issue when the speaker are in standby mode (thus red light on the control pod) and when I switch them on via the remote control or the control pod. It makes a strange noise in the subwoofer ("clic"), the red light disappear, then a new noise and the speakers are switched on. The problem is that all volume levels (rear / side / center / sub and main) are reinitialized! I have to configure them each time this problem appears...
    I have a Creative Sound Blaster Audigy 2 ZS connected to this speaker system. For me it is related to an electrical problem in the subwoofer like if the voltage was not stable (variations).
    Regards,
    Vincent

  • CSS with SSL module - how many certs do we need

    Hello,
    currently moving from server-based certs to CSS/SSL based.
    We have two sites, two CSS/SSL on each in ASR mode.
    There are two real servers behind each SSL rule for load balancing.
    The question becomes how many certificates do we need
    for such design ?
    For sure we need one per site, then on each site we have Active/Standby CSS's.
    Do we need separate certificate for each CSS?
    I dont think so, cause only one is active at the time.
    I tested it with same certificate on both CSS's on one site, no problem.
    The question is will it be ok for production ?
    So total number would be 2 cert for such design (one per VIP) if we have one SSL rule per site, and 4 if we have 2 SSL rule per site - is it ok ?
    Thank you,
    Alex

    the certificate is linked to a host name ie: www.mycompany.com.
    So, if you have 4 css, all handling traffic for www.mycompany.com, then they can all share the same certificate.
    Even if you have the 4 CSS split over 2 sites, using different vip, as long as they handle the same hostname, then they can share the certificate.
    Actually, the CSS itself does not care about hostname/certificate mapping.
    The CSS will use whatever certificate you configure it to use.
    However, browsers make a check url <-> certificate and if there is a mismatch, they pop up an error message.
    Regards,
    Gilles.

  • How many EoIP tunnels at the same time? (One Anchor -- HA Pair )

    Hi Experts,
    With AP SSO, there should be two CAPWAP tunnels between an AP and the HA controller pair at the same time. Is it correct?
    Then how many EoIP tunnels between the internet anchor controller and the foreign controller HA pair at the same time?
    Thanks
    Cedar

    Hi Cedar,
    in AP SSO, only single CAPWAP tunnel maintan at a time & see the below reference for details.
    http://www.cisco.com/en/US/products/ps10315/products_tech_note09186a0080bd3504.shtml
    There is only one CAPWAP tunnel maintained at a time between the APs and the WLC that is in an Active state. The overall goal for the addition of AP SSO support to the Cisco Unified Wireless LAN was to reduce major downtime in wireless networks due to failure conditions that may occur due to box failover or network failover.This allows the access point (AP) to establish a CAPWAP tunnel with the Active WLC and share a mirror copy of the AP database with the Standby WLC. The APs do not go into the Discovery state when the Active WLC fails and the Standby WLC takes over the network as the Active WLC.
    in the same sense, EoIP tunnel limitation will be 71 for a anchor controller. See below
    https://supportforums.cisco.com/thread/2123756
    HTH
    Rasika
    *** Pls rate all useful responses ****

  • How Many Times Can I Use The Same Serial Number For Adobe Creative Suite 4?

    I have design standard and was told I can use the same serial number on multiple computers. How many time can I use it? And say I install it on the maximum number of computers, but get a new computer, can I uninstall it on one of the old computers and use it on the new one? And can I use the programs on both computers simultaneously or do I have to use them one at a time?

    Fred Tech wrote:
    Broadly speaking, it depends on the type of license you have.
    Specifically, if you have a single license then officially, you should only install it once on one computer.
    Practically, (unless it has changed with CS4) you maybe able to install it on more then one computer, BUT can only run one instance of the software at a time. You can not run more then one instance of the software concurrently; i.e. you can't run Dreamweaver on Computer 1 and Photoshop on Computer 2. That would be two instances, and is not permitted.
    This is my understanding. I am happy to be corrected if I am wrong
    Fred
    Sorry Fred you are wrong.
    If you have a single license you can install it on as many computers as you like. you can only activate the suite on two computers at anyone time. Work and Home or as many of us do it Desktop and Laptop. You can not use the computers simultaneously. You only have 20 activation/deactivations so use them wisely. Student versions only have one activation. You can not break up the suite installs the suite is considered one application.

  • HT5622 How many family members, computers, iPods,iPad,IDs can you have on one iTunes account?

    I'm just trying to sort out some iTunes I'd issues.  Does anyone know how many total iPad iPods can be used with one Apple ID?  Or how many apple  IDs your can have with one iTunes account? Or does each person need there own Apple ID or Apple account? Thanks

    You can't have multiple IDs on one account, but you can use multiple IDs for different purposes on the same device.
    Just use the one AppleID for iTunes and the AppStore so you can all share your music and app purchases. Then each person should have their own individual AppleID with associated iCloud account for mail, contacts, calendars, iMessage and FaceTime.
    You don't have to use the same AppleID for all services.

  • Want to use Adobe forms departmentally.  How many users per license?

    How many people can use Adobe Forms per license/how many computers can we download software to?

    Adobe FormsCentral is a web-based app so there is nothing to download - you access from the web browser.
    Each users who creates forms needs a license of FormsCentral. In a month or so you'll be able to by a team pack (5,10,25) at reduces prices for a larger group who wants to create forms.
    Randy

  • How many calendars can you share with the same iCloud person?

    OK Apple people, here is my concern:
    I have several calendars in my iCal app.  I can share one (home) with my wife but for some reason, I am not able to add her to another calendar that I wish for her to  view/edit (work).  She does have an iCloud account.  The documentation on the Apple web site for iCloud states:  " You can share a calendar both publicly and privately with other people. Sharing gives you flexibility in managing calendars. For example, you could create a calendar for your child’s sports team and share it privately with just the coaches so they can edit it. You could also share it publicly with all the parents so they can view (but not change) it whenever they want."
    Is there a limit to just how many calendars in the application that one one can send as suggested by the "a"?
    Thanks in advance for your responses.
    RAP

    All my family devices are tied to one Apple ID.  We did that b/c we would consolidate our purchases by syncing via 1 Mac in the house.  So any device could purchase an app/music/whatever, then we would plug it into the main Mac and transfer the purchase to that and then plug in other devices and add to them.  Pain the rear!  I think my example of tedious process above is one reason for iCloud.  So, now with iCloud we should be able to purchase from any device and the other devices would have access without wires.   I thought the only way to tie them all together is if they are all under the same AppleID.  That is how iCloud knows they are related, right?  Makes sense to me.   However, on each device, we use their own @me/@mac email account to setup iCloud b/c each email is tied to that family member but under the master Apple ID for our family.  Each email account has their own contacts, emails, etc.  I thought that was the way to setup.  Shouldn’t this work?  Kind of separate but yet tied together via the 1 Apple ID.  Thoughts?

  • How many times can I review my account ?????????

    I have reviewed my account three times with my PayPal info and received confirmation from my PayPal Account but it still won't let me log in. It wants me to review EVERY time. Let me know if anyone can shed some light on this problem.
    This is a REAL PAIN.
    Thanks, Andy

    Lfc89 wrote:
    How many times can I change my country or region on my ipad 2 or iPod touch 5
    Not sure what you are asking... but...
    See  >  Change your iTunes Store country
    Here  >  http://support.apple.com/kb/HT1311
    Settings > iTunes & App Stores > Apple ID: > View Apple ID > Country/Region = Change Country / Region

Maybe you are looking for

  • My iPod will not show up in the Itunes device list plus I get an error message

    Hello! My iPod will not show up in the Itunes device list plus I get an error message " One or more devices is getting too much power from the USB wire" or sumptin like that. I've tried this with two wires, so the problem is not there. I reseted the

  • Windows 8 Problems with initial instalation...

    All, Can you please give me some advice on installing Windows 8 on a Macbook Pro 13 inc early 2011 model? This is a compleatly fresh instalation onto a new Samsung SSD Hard drive... I do NOT have any instance of OSX on this computer (My Mac OSX Mount

  • No volume control elements and/or devices found

    Hi, I recently installed Arch Linux and I followed the tutorials on how to configure it. At this moment I have Gnome installed and it is working fine, I only have one problem. Every time if I try to access volume control I get the following error: "N

  • "digital signature on the update is missing or invalid" 10.6.8 combo 1.1 from 10.6.3.

    Also got posted in '10.3 or earlier' community, where other posts are regarding this issue ... I get "digital signature on the update is missing or invalid" trying to install 10.6.8 combo on MacBook currently using 10.6.3.  Have used Disk Utility, Re

  • Bug in SQL Developer 1.5 SQL Worksheet

    Hello, did any of you already encounter the following effect in version 1.5's SQL Worksheet? When I try to execute the following statement in version 1.5: select (1 + 2 - 3 + 4) from dual; I get the error: ORA-00907 missing right parenthesis With mor