Hi ABAP/EDI Specialists,
1How to Assign Logical System to a Client. In the SALE transaction window.
I didn't see any Receiving and Sending Systems(Tree). But I can see Logical Systems. In the Definition and Assign Subtree are there. I created two Logical Systems STUD_S and STUD_R. When I executed Assign Logical Systems. I got a window, Where I can see a list of Clients. I got confused, how to Assign those Two Logical Systems to Client 800 and 810. Finally I double Clicked on each client and in the next window. I changed the Logical System to STUD_S for Client 800 and Logical System STUD_R for client 810. and saved them.
Is this procedure correct???
Why I need this is, While generating partner profiles in ALE Model (BD64), I am getting no list at all. When I executed I got no list.
"No messages have been defined for the selection conditions in the Model"
I got struck at this point.
Please help me to come out of it.
Thanks,
Chinna

Hi Chinna,
Thanks for such a valuable information. I am able to move further. But i got struck while generating parntner profiles from ALE distribution model.
Log For Partner Profile Generation:
Partner:
Partner ZVK_SS_800 as partner has been Created ( Sending System)
Partner ZVK_SS_820 as partner has been Created (Receiving System)
Port:
Port Cloud not be Created
RFC destination ZVK_SS_820 not specified for system ZVK_SS_820
Enter the RFC destination and Restart the generation
It is not recognizing the RFC port, even though i followed all the steps correctly.
While creating RFC destination, can someone tell me How to fix the above error and what is the Client No, Username and Pasword i have to give.
Thanks
Chinna
Edited by: Chinna on Jun 6, 2008 7:43 PM

Similar Messages

  • Assigning logical system to a client in CUA

    Hi All,
    I have got a doubt in the basic configuration in the setup of CUA.
    I have performed all the steps that is given in the CUA cook book.
    In, assiging the logical system to a client, whether this step shoud be done only in the central system alone.
    Or the assignment should be done in the child system also.
    When i created the all the steps in central system, logical system is created automatically in child system. but in the client assignment i didn't find information. in cookbook also they have do it in all the SAP system.
    kindly advice.
    Thanks and Regards,
    Subhashini.

    >
    > So creating clients in Central system is enough for the child system.
    The term you used "Creating Client" is technically wrong in this regard. You already have a client which is in use as Central system - right? You need to maintain the details of Logical system names of all the Child system in Central system to keep the central system updated with the knowledge of type and name of the Child systems it has. This definition can be done by using TCode BD54 which is table maintenance view ( V_TBDLS ) of the table TBDLS.
    There is nothing to do or even can be done like Creating Client within a client (here your central system).
    > Since there is noe transfer of user master from child to central system no need to create a client for the logical system.
    >
    Its true that there will no transfer of user master from child to central system. But of course the similarly here you are not creating any client within the child system. You are just creating the logical system name (tcode BD54) for this client (child system) and mapping it with the client in tcode SCC4.
    Let us know your question. Also as suggested by Barnherd, please go through the SAP Help documentation on CUA. Also try to get an overview of Client in SAP (from SAP Help or SAP course ADM100) and Logical Systems.
    Regards,
    Dipanjan

  • About  assigning logical system name to client

    Hi:
        the SAP landscape is:
        CRM DEV CR0 (CLIENT 200)        -
    >    CRM PRD CR1 (CLIENT 800)
                      \|/                                                                        \|/
          ERP DEV MZ0 (CLIENT 200)      -
    >   ERP PRD MZ1 (CLIENT 800)
       the crm dev is connected the erp dev and the crm prd is connected the erp prd.
       the CRM version is CRM2007 and the ERP version is ECC 6.
        My question is :
       Can the logical system name of the prd client 800 be same with the dev 200?
       Could you give me any advice?
    THANKS.
    Edited by: Xiaofeng Qiu on Jun 5, 2009 11:27 AM

    Hi,
    The logical system must be unique company-wide. In a production system, the logical system must not be changed.
    Goto SCC4-->Double click on any client number. You will see logical system text. Select it & press f1 you will below information about logical system.
    "The distribution of data between systems requires that each system in the network has a unique identification. The logical system is used for this purpose.
    In the SAP System the client corresponds to a logical system.
    When you maintain the logical system, note the following:
    The logical system must be unique company-wide. It must not be used by any other system in the ALE integrated group. In a production system, the logical system must not be changed."
    Thanks
    Sushil

  • Regarding problem while assigning logical system

    Hi Friends,
    I had a problem while assigning logical system to the client where in both of my systems are having same client number which belong to 2 different systems.
    while assigning the sender and receiver logical system to the same client i am facing problem stating that an entry has already been made for the same key.
    could any one plz give me a clear idea...while assigning logical systems (cross clients) for 2 different systems having same client number.
    Regards,
    Madhu

    Hello Madhusree,
    I'm running with same problem. I've created two logical systems and assigned them to two different clients. But here pops up the issue while generating partner profiles, throwing error "No active plan version exists". Later when I researched about the issue, I came to know that T77S0 table doesn't have any entries regarding plan versions. Basically, I created two clients by doing "client copy" from source client (800 & 100). And I could see plan version entries in the T77S0 of client 800. So, I thought of assigning just defined logical system to the source client 800 itself. But it throws error saying "entry already exists"; as client (800) is already assigned with other logical system.
    By coming across your post, gives me leap of hope that two logical systems can be assigned to same client. Could you please share me those troubleshooting steps concerning this issue. Points will be awarded.
    Regards, Anil. 

  • Re: Assign Logical System to Client

    Hi Guys,
    Currently our BI client 100 is connected to ECC client 140. Now I want to connect BI client 100 to e-recruiting client 180.
    How to do this?  How to assign same client to different logical systems?
    Regards,
    Anand

    first i created logical sytem for erecruiting.
    for BI the logical system already defined as it is already conected to SAP ecc.
    Second step using tcode SCC4, now how to assign the logical system of e recruiting to BI client 100.
    Already BI client 100 is assigned to SAP ecc logical system.
    Its not allowing me to define another logical system for same client.
    Am i doing the right step?
    Regards,
    Anand.

  • Assign Logical System to client 000

    I need to install Bw at SAP ECC 6.0, in doing so on the client 000 with the transaction RSA1, present the message that should be assigned System logical customer 000, it does not bring inconvenience to any future activity,
    Thanks

    Hi Victor,
    If you're installing BW you shouldn't use cleint 000, create a new client...
    Once you create the client go to transaction SALE and You'll see Create logical system ans assign logical system in the list.
    First create a new logical system for the client to use... then assign the logical system to the client.
    Regards
    Juan
    Please reward with points if helpful

  • Assign logical system to client

    I understand that we assingn a logical system to a client in tcode SALE.
    However my Q is if say i have one receiver system YXD/800 and another receiver system RXD/800 ....
    when i try to assign client 800 to these 2 receiver systems it allows me to enter only one receiver system..
    Cannot I assign same client ( say 800 ) to two different receiver systems

    hi ,
    according to my understand about your post,
    you transfer the data across the three users of 800 client.
    you have to create three logical systems for three clients.
    then you can maintain RFC destination across two systems by using SALE.
    Regards,
    karunakar

  • How to create logical system

    Hi,
    How to create logical system.
    Please help me with the steps for logical system creation in R3 system.
    Thanks,
    Kelly

    Hi,
    First make your client modifiable, then follow the below procedure.
    Go to transaction SALE or BD54 -> Sending and Receiving Systems -> Logical Systems -> You'll see "Define Logical System" and "Assign Client to Logical System".
    For more information use below link.
    http://help.sap.com/saphelp_nw70/helpdata/en/da/5990df015b5b43a36f6ce7fa1ee8c0/content.htm
    Thanks,
    Mano

  • Relationship between logical system and a client

    Hi,
    Our internal notes say that, in order to create a new client, I must do the following:
    1. Create a logical system using BD54. The client name must be SID + "CLNT" + number. In my case, this would be NSPCLNT100.
    2. Create a client using SCC4.
    Questions:
    1. What is the relationship between the client and the logical system?
    2. How does SAP know that client number 100 must be related to NSPCLNT100? I am not specifying this relationship anywhere.
    Thank you in advance for your help.
    Regards,
    Peter

    you assing logical system to a client from SCC4

  • Assign Logical System both in GTS and R3

    Hello all,
    We are using Two different system for R3 and GTS , and defined logical system both systems ( for R3 QR1CLNT100 and for GTS QG1CLNT100 , now do I need to assign logical system both system for clients in R3 and GTS ( I mean at the time of assignment both clients QR1CLNT100 & QG1CLNT100 i have to assign in both systems  or only one.   For Feeder system only I need to assign GTS system logical system as QG1CLNT100 vice versa ( for GTS system need to only Feeder system logical client QR1CLNT100)
    Thanks in advance for valuable inputs.
    Thanks & Regards
    Tarun

    There are following steps  for doing connection between R/3 and GTS
    1. Define Logical System
      Here you have to define both R/3 logical system as well as  
      GTS logical system.
    2. Assign Logical System.
    Here actually when u get in you will see the physical system
    detail on which you are logged in , suppose you are on R/3 you will find detail of R/3 system with different clients. Some clinet willcome as default like 00 which is waldrof client the SAP client and other are are those which are created at the time of installation.
    Here you have to assign the logical system of R/3 to the physical system client combination on which you looged in.
    you will find a field  of logical system on the top once you get in detail of the client system combination.
    Now here we have assigned the Logical system of R/3 this is required as when GTS will communicate wiht R/3 it willtry to look for  R/3 logical system as for RFC connection we always define logical system to which the system will talk.
    this configuration we do under Maintain RFC connection for RFC call Tcode SM59
    3.  Maintain RFC connection for RFC call Tcode SM59.
       Here we define the Target host, and logon detail like 
       language , client, user passwaord.
       We need to define the detail for GTS for RFC connection and   so we need here the logical system of GTS.
    4. Maintain RF destination for method call
      Here again you will require GTS logical system .
    5. Maintain ALE distribution here you will require both R/3 and GTS logical system.
    Hope it helps
    Kind Regards,
    Sameer

  • RSTCO_ADMIN - "No logical system exists for client 100"

    Hi all.
    I am trying to run RSTCO_ADMIN in a BI 7.0 SP11 system. The activation stops / fails, and in the log I get a warning message saying:
    "No logical system exists for client 100".
    In SALE and SCC4 I have created a logical system TBQCLNT100 and assigned it to client 100. Client 100 was created with a client copy from client 000.
    Does anyone know what I have to do to fix this?
    Thanks!
    Best Regards,
    Thomas

    Thomas
    Check if you have configured the RSADMINA table, here you will see a "bw client" filed, put 100 as your bi client.
    Regards

  • Hi how to create logical systems.

    Hi,
       how to create logical systems. Do we need to create logical system name for creating RFC destinations? plz help me out.
    thanks
    dhanush.

    Hi,
    transaction:
    SALE -> Basic Settings -> Logical Systems -> Define Logical System
    No, you don't need to create Logical Systems to define RFC destinations.
    Regards,
    Jakub

  • How to assign more system memory in PE 10?

    PE10 has crashed a number of times and will not allow use of Ken Burns.  Searches retrieved information on how to assign more system memory in previous versions of PE, but the methodology explained could not be used for PE10 as the relevant actions could not be located.
    What worked in a previous version of PE:
    > Edit > Preferences > General
    In addition, the guidance suggested 1.5 should be enough but if the recommended amount for PE10 should be different (particularly for Ken Burns), advice would be most welcome.
    Thank you.

    Welcome to the forum.
    What are the complete specs. of your computer, including the OS?
    For the Still Images, this ARTICLE goes into much more detail.
    Also, for a PC, after one gets past the initial "checklist," in this ARTICLE, there are many links on setting up one's computer for a video-editing session, and for tweaking one's OS for max results.
    Good luck,
    Hunt

  • How to name logical system

    Hi!
    I need to define logical system (creating source system fo BW). I found that there is a rule set for naming:
    SystemName + CLNT + ClientNumber
    Is it so?
    Can I create some logical system for one client in one system?
    Thanks,
    OLga

    Hi,
    It is not Mandatory to have the Name like that only.
    We do have different names for different Clients.
    Regards,
    Anil Kumar Sharma .P

  • How to adjust logical system after coping PRD to QAS in tabels

    Hello
    I wonder how to adjust logical system after coping PRD to QAS in tabels. I know (the logical system changes) but there is a transaction which adjustes entries in tabeles...

    >
    Tina Tajnist wrote:
    >...but there is a transaction which adjustes entries in tabeles...
    SE14

Maybe you are looking for

  • Unable to find open item in F-44

    Dear Guru's, One of our client have raised a accrual/defferal entry in FBS1 on the date 31.06.2011(goods in transit Dr, vendor Cr) and again he has reversed the same entry in F.81 on 23.08.2011 and now he wants to clear the open item in F-44 for the

  • How do I move my iTunes Store account from Canada to the US?

    I recently moved from Canada to the US, but when I try to change my iTunes account from Canada to the US, I get an error: "Your request is temporarily unable to be processed." I've followed the instructions over and over, and contacted iTunes Store s

  • Charge An iPod Touch On A Windows 98se

    I have a 98se desktop computer with USB 1, I know the requirements are USB 2, BUT, I read here that people were having problems with syncing with USB 1 and worked perfectly with USB 2. So the above tells me that it WILL work with USB 1 but it transfe

  • How to send this command to RS232 Port

    I want to use LV to control a label printer to print what I need. Following info is from printer user manual. From RS232 port: If Codex has been used with the controller then the simple serial protocol will need to be enabled by sending ESC Z SWITCH

  • Lock table Overflow as the file size is 50 MB BW side.

    Hello Everyone, I have a XML idoc file as input which is usually more then 50MB in size. Usually, i am getting Lock table overflow at Receiver BW side . This error is pointing to Inbound_Asynchronous_Idoc. i have tried dividing the Input XML idoc fil