How to change original source system of objects at one time

Hi, experts !
I installed extra devlopment server using system copy of orignal
delveopment system.
We have planed that new objects applied to orginal server after developing
finished on extra devlopement server.
The problem is we can not modify or add old objects for specific
package because orignal source system is different
and I know this is SAP policy.
Of course original source server can be changeed on t-code SE03 or
function module TRINT_TADIR_MODIFY
but it should be applied to every objects. This is big job to BC admin.
Is there any solution to possible it at one time?
Best Regards

You can transport all relevant packages from the old to the new development box including a change of the original system using a special transport request of type "relocation of complete package". Check with your system administrators.
Please close your similar post here:
How to change original system SID to objects by batch?
Thomas

Similar Messages

  • How to change the source system for just a datasource

    Hi,
    Our test/development BI system ( BI 7.0 Unicode ) is connected to our development system and to our test system, 1 BI system connected to 2 R/3 systems.
    During some time, the test system won't be available so all datasources that point to the test system must be connected to the development system. In RSA1 is not possible to change the source system in a datasource: RSDS 057
    'Creation of DataSources for SAP source system D30CLNT007 is not permitted' , same error trying to copy the datasource,.
    Any idea about how to proceed ?
    Regards,
    Joan

    Hi,
    If I try to repliclate metadata in the datasource, message RSAR 051 appears: 'error when opening an RFC connection'. This error is expected because the logical system pointed in the datasource does not exist.
    Is not possible to change the source system in datasource ( in RSA1 ) because the field is always greyed, also if I try to copy the datasource the message RSDS 057 appears.
    Any idea about how to proceed ?
    Regards,
    Joan

  • How to change the Source system from ONE DataSource?

    Hi,
    I'm trying to change a DataSource's source system (active with dtp and transfer rules), but it's not possible to  do it in change mode because the field 'Source Sytem' is not enabled. I know I can use the BDLS transaction but I understand that this is for change all Datasources and I only want to change one of all.
    Thanks for your help

    Hi Marcel,
    As I understand apart from file and web services all other data sources are replicated from underlying source system. BDLS transaction is used to change the source system but in case of system copy activity and it is necessary because the data sources points to old source system.
    In your case as I understand you will have to replicate the current data source directly from underlying source system and then build the rest of the flow. May I know how you have got this single data source for which the source system is different?
    Regards,
    Durgesh.

  • How to change a source system

    Hello,
    we have just copied our BW productive system on the consolidation system. With this copy on the consolidation system now exist the source system to our productive R/3 system.
    I would like to connect the bw consolidation systen with the R/3 consolidation system.
    Does anybody now a possibility to switch the existing source system "R/3 productive" to "R/3 consolidation".
    All source system related objects (infopackages and so on) should be switched to the new source system too.
    Thanks
    Frank

    Hi,
    Roberto's answer is correct but it is making the assumption that all the DataSources in R/3 production are the same in R/3 QA.
    Once you have done the BDLS in BW for the source system technical name, you will have to do a source system check and restore. This will check the idoc and low level communication settings.
    As Roberto states, SAP note 325525 is the best source of information.
    Finally, you will have to deal with the data differences. Your data in R/3 QA will not be the same in R/3 PRD. This is a manual process.
    Cheers,
    Mike.

  • How to change original language of ABAP objects?

    HI,
    I have created a BADI and an interface in R/3 release 6. I created the BADI in original language German, but by mistake I created the interface in Original langauge English.
    Is there a way to change the original language of the interface to German? I tried editing and activating the interface in German logon, but it did not help as teh Original langauge of the interface remained as English.
    Is there any SAP report which would help me to change the original language of ABAP objects?
    Regards,
    Srini.

    Hi,
    Here's the way out:
    Step 0. Delete the object
    Step 1. Delete the object directory entry(If it says entry doesnt exist, recreate it - ie. the object dir. entry)
    Step 2. Login to the language of choice - In ur case 'DE'
    Step 3. Recreate the new object
    Voila!!! Original Language changed
    Cheers,
    Gaurav

  • How to change the source system

    Dear Experts,
    I have Ecc1 as one of my source systems to BW Quality.Now the client wants to stop the present source system and wants to get the data from new source system i.e. Ecc2. To divert the present flow to new flow.I have looked the previous post regarding the same but are not clear to me. could some one let me understand steps to look into.
    Thanks Regards,
    Mannu

    you need to maintain RFC to the new source system
    delete old source system
    create source system connection from RSA1
    Run BDLS to point the data sources to new source system. This should be run on both BW and ECC.
    See the below post
    https://forums.sdn.sap.com/click.jspa?searchID=1255799&messageID=2880041
    Re: R/3 to BW Connectivity
    Re: RFC Connections

  • Change the source system

    Hello
    In our Quality Box , I need to change the source system connection (from QR1 to QR2). I created the new connection successfully. Now the issue is all the Transfer structure still using OLD connection ( i.e QR1) . I run BDLS and it did not word. How can I re-assign the new source system (QR1)  to all of my Transfer structures in one go. Is there any report ?
    Farooq

    Hello,
    You cant directly convert the existing objects for a source system to the new source system.
    For that you need to do a transport of the objects to the QA box while maintaining the entry in BDLS to convert to the new source system.
    Regards,
    Shashank

  • Reg Change of Source system in BI Producton

    Dear All,
    We had a R/3  source system 900 and data was getting loaded from this client  to BI 600 client everyday.
    Scenario:-
    Nowin R/3 the client system is changed from 900 to 950 and 900 client is no longer available.
    Problem:-
    What are the steps we need to take care of in BI system since the source system (client) has changed
    Kindly give your inputs for the same.
    Thanks & Regards,
    Khan

    Hi Khan,
    Please follow the below steps:
    The requirement is that Clients 900 connection should no longer exists in BW and replaced by clients 950
    Below steps would hold good if the datasources of  CLNT950 & CLNT900 are identical.
    1) Delete CLNT950 in BW (no Datasources of this system is used in BW)
    2) run BDLS in BW change CLNT900 to CLNT950
    3) Run RSAP_BIW_DISCONNECT in 950 clients ..
    4) Restore connection CLNT950
    Please remember to make a transport of source system dependent objects(for the original connection) on BW side, else you lose all the transfer rules and stuff. It has to be reimported later after mapping the old and new source system connections in table RSLOGSYSMAP.
    Hope it helps,
    Thanks,
    Amit Kr.

  • Virtual Transport Path to move BI source system dependant objects.

    Currently, our BI Test system (which contains all Transported Objects from BI Dev) is connected to ECC client 100. We want to change BI connection to different Client i.e ECC 115 (this client contain better test Data). We have removed BI connection from Client 100 and connected to Client 115. But our entire Source System Dependent Objects in BI still point to ECC Client 100. To change these Objects to point to the correct Client 115, we are executing the following steps:
    1 Remove Source System ECC Client 100 from BI2
    2 Connect New Source System ECC Client 115 to BI2
    3 Ensure that New Source System Connection to Client 115 have been set up
    4 Create a virtual transport path within BI2 for re-import into BI2 queue for the “ ? ” Transport Package
    5 Open BI2 to assign user authorization in order to be able to create a transport in BI2
    6 Copy Source System dependent rules & create Transport
    7 Change the Source System Assignments on the target client
    8 In SE09 - check that only the required source system has been copied
    9 Move the transport in through the import queue
    We are stuck at step 4. Basis team says it is not possible to create a transport path from BI2 system to the Virtual System (in the same BI system) and move it. But I am pretty sure that this can be done as I did this earlier in my previous project. This is something related to Basis so I can’t help them.
    Do you have any idea, how this can be done?
    Any help will be highly appreciated.

    Hi
    I do not understand few things :
    - why did you remove the source system ?
    - what do you mean by BI2 ? It is the same QA system as before....So why do you need to create a virtaul path for transport ?
    The steps you should have followed is to use BDLS transaction to rename ECC100 to ECC115
    The source dependant objects would have been renamed automatically.
    By the way, you now can start over from your dev and collect the source system dependant objects
    Transport the request in QA, paying attention to change the transcodification table to target ECC115 and not ECC100...
    Hope it helps
    PYG

  • Changing the source system in QA

    Hello All,
    I just wanted a quick opinion from your experience on the following issue:
    We  have a ECC Dev client 20 connected to BI Dev client 20
    Similarly we have ECC QA 120 connected to BI QA 120
    But due to some reason we now want to connect a new ECC QA client 150 to BI QA 120 and take out ECC QA 120 totally(120 is wiped off).
    I already have a lot of development transported to BI QA where the source system is ECC 120. Now if 120 dies and we pull the data from 150, what are the pitfalls to watch for?
    Like all my Master data objects , DSO and Cubes still point to ECC QA client 120 but now the "actual" source system is going to be ECC QA 150.
    Points,
    Gaurav

    You need to replicate all the data sources in BI from QA 150 and change the source system assignment to 150 instead of 120.
    Also, you need to reinitilase delta for delta enabled extractors.
    Two  things to watch out:
    1.  If you dont have source system identifier,  then if you happen to get records with same key, then it will overwrite. This applies to both master and transaction data.
    2. For transaction data that is not delta enables, there may be a possibiltiy with which the records will get duplicated. So, better to delete the old requests before reload the data from QA150.
    Ravi Thothadri

  • How to change the title of an object in the build order window?

    In Keynote '09 v5.1.1 (1034)... How to change the title of an object in the build order window from the default "dropped image" to a specific title?
    I'm running the following:
      Model Name: MacBook Pro
      Model Identifier: MacBookPro2,1
      Processor Name: Intel Core 2 Duo
      Processor Speed: 2.33 GHz
      Number Of Processors: 1
      Total Number Of Cores: 2
      L2 Cache: 4 MB
      Memory: 2 GB
      Bus Speed: 667 MHz
      Boot ROM Version: MBP21.00A5.B08
      SMC Version (system): 1.14f5

    Custom names can't be applied to objects in the build list.
    They are labeled as either; text, shape, table, chart or the filename of an image

  • How to replace a source system with another in BW

    Hello experts,
    I've read many topics dealing with my customer's need, but I still can't find the solution.
    My landscape is the following one :
    ECC6 with DEV, QUAL and PROD
    BW with DEV and PROD
    BW DEV source system is ECC6 DEV, I need to change it to ECC6 QUAL
    A lot of work has already been done, and I'd like not to lose it changing the source system.
    Datasources are the same in ECC6 DEV and QUAL.
    This is not a system or a client copy, it is really a source system switch.
    The new source system is already created (both DEV and QUAL ECC6 are available in "source systems" in RSA1), and I tried to use BDLS tcode
    In the "old logical system name" I choose my current source system and in "new logical system name" I choose the one I now need to use.
    System answer is : "The logical system name ECC6 QUAL already exists"
    Obviously I did something wrong, but can't figure what.
    Is there any action to perform before BDLS ?
    Any help is appreciated, and points will be given.
    Guillaume P.

    Thanks for your answer,
    "relevant object" means for you datasources, transfer rules and transformations ?
    With the grouping option "Save for system copy" I can't take easily all datasources, and others objects
    Will I have to pick all object one by one ?
    What would be the adjustement in table RSLOGSYSMAP ? For the moment it's empty.
    Regards
    Guillaume P.

  • How to change the source ip address

    hi all,
    i got the problem that how to change the source ip address when i
    get a website's page!
    i mean i want to change the source ip address when i access the
    remote website, sure i know when change the source ip, i can not get
    the result correctly when changing the source ip address, but it is not
    important to get the result i just want to send out a "click" event to the website by calling a post method in the site!
    does anybody have some ideas?
    Best Regards,
    Eric Gau

    Here's some code that connects to google and does a get:
    import java.io.*;
    import java.net.*;
    public class HTTPTest {
        private Socket sock;
        private BufferedReader in;
        private BufferedWriter out;
        private boolean running = false;
        HTTPTest() {
        private void go(String site) {
            try {
                sock = new Socket(site, 80);
                in = new BufferedReader(new InputStreamReader(sock.getInputStream()));
                out = new BufferedWriter(new OutputStreamWriter(sock.getOutputStream()));
                System.out.println("Connected");
                out.write("GET / HTTP/1.1\r\n\r\n");
                out.flush();
                doRead();
            } catch (IOException e) {
                e.printStackTrace();
        private void doRead() {
            running = true;
            String line;
            System.out.println("Read started");
            while (running) {
                try {
                    line = in.readLine();
                } catch (IOException e) {
                    e.printStackTrace();
                    line = null;
                if (line == null) {
                    running = false;
                } else {
                    System.out.println(line);
            System.out.println("Socket closed");
        public static void main(String [] args) {
            String site;
            if (args.length > 0) {
                site = args[0];
            } else {
                site = "google.ca";
            new HTTPTest().go(site);
    }

  • How to delete a source system in BW?

    Hello All!
       Can anone please  inform me about the procedure to delete a source system or inform me in which document i can find this information. Actually i wish to assing my newly installed BW3.5 system to a new logical system (i.e) its currently assigned to some other logical system where it has ME as default source system.  to change the logical system we need to delete all the source systems in the old logical syste. So please explaing me how to delete the source system Myself(current BWsystem). there is no data and no data sources existing in the system its abosolutly fresh.
    Thanking you for help in advance
    with regards
    Ashwin Kumar Gadi

    Hello Roberto!
        Thanks for ur response. But there bo such delete option  available under the context menu for the source system for the Myself source(current BW). only change buton appears but when we click that it say changes are no posible. Is the any other way to delete it manually.
    with regards
    Ashwin

  • How to verify the  Source systems connectivity with BWQ System.

    Hi All,
    I have diff source systems. And my requirement is to check the source systems connectivity with BWQ (BW Quality sys). please any body tell me the steps how to check the source system connectivity ?
    Thanks & Regards,
    Manju

    Hi Manjula,
    If you encounter problems when establishing a connection to your target server, check the following:
    A message box appears while performing one of the following actions:
          Setting connection by choosing Apply to local session.
          Testing connection settings by choosing Test settings.
          Creating SAP TSQL objects
    If errors occurred, they are displayed in the respective message box.
       Check developer trace files in ST11.
      Test connection:
         For RFC related errors, check the RFC connection via SM59
         For database multi-connect errors, check if you can connect to the target SQL Server with the SQL Server Query Analyzer. Also check if the DBCON entries are correct.
    Regards,
    RK

Maybe you are looking for

  • PC Card Slot

    What goes into this slot and what ever it is, what is it used for?

  • How Can I highlight a Subject/Person on a video clip?

    I am trying to create a highlight video for players on our high school team.  I can clip/freeze and slow down portions of the clip but I am looking for an easy solution to either draw a circle or shadow out the balance of the frame for a second to hi

  • Can I work in ID CS3 from version 4?

    I am a student and currently have CS2, I am looking to upgrade to CS4. I have to go to CS4 because I can no longer get CS3 at a student price, however everyone I work with and the university mac labs all still use CS3. I understand when using InDesig

  • Schedule Task - Windows 2008 R2 - User Session

    I am migratiing the schedule task from windows 2003 to windows 2008 and find some of behaviour change on handling user session by Task Scheduler. I have a simple batch to call "net use" command to map a network drive for copying file to remote server

  • Account 233000 needs assignment to CO Object

    Hi Im trying to post differences in Physical Inventory and this error appears. What are the possible reasons and how do I fix. Vishnu