How to configure StorEdge 3510 as a SAN?

Hi all, just joined!
We've got a StorEdge 3510 set up as a DAS (private loop mode) connected to three servers. We've gone through hell and high water getting things configured (firmware upgrades were particularly troublesome), but now that we've got everything running, we're starting to think about future expansion. However, despite my experimentation, I can't work out how to set them up in a switched fabric.
We have a test 3510 set up as Point-to-Point, connected to an Emulex 355 FC switch. In Loop mode, the device shows up as a SCSI device, but I can't get Windows to see anything on the end of the HBA when it's in PTP. Half the time, the HBA won't even acknowledge a link.
I can't work out where to start with this. The switch, admittedly, came from Apple with an Xserve RAID, but we've had the 3510 plugged into it in Loop mode and visible, so I don't think there's any problem with Apple ROM-ing the switch.
I've tried Zoning the switch, and Smart-Setting the ports to be Switched Fabrics, but nothing seems to make the StorEdge visible to the host. I thought that the test box might be at fault initially, since it has a Dell-EMC FC HBA and it wouldn't surprise me if it's ROM'd to EMC boxes only, but it seems that another box with a generic QLogic card won't see the StorEdge either.
Full tech specs of the system:
-3510 dual-controller, firmware 4.23A, 12 146GB 10K disks
-Emulex 355 12-port FC SAN Switch
-Dell PowerEdge 1850 with Emulex LP1050Ex-E PCI-E HBA
-Dell PowerEdge 2850 with QLogic QLA210 PCI HBA
-Windows Server 2003 x64
Any advice or starting points would be massively appreciated!
Thanks,
Rob

You are right in changing the A3510 to point to point
From:
sccli> sho host
max-luns-per-id: 32
queue-depth: 1024
fibre-connection-mode: loop
inband-management: enabled
To:
sccli> sho host
max-luns-per-id: 32
queue-depth: 1024
fibre-connection-mode: point-to-point
inband-management: enabled
The 3510 is now configured to work in a SAN.
In loop mode you will see the enclosure as an ses device. In point to point you won't, you will just see the available LUNs.
In P2P you should see all your configured logical volumes or disks with there WWN names on the hosts side
From:
sccli> show logical
LD LD-ID Size Assigned Type Disks Spare Failed Status
ld0 5E714957 545.91GB Primary RAID5 5 2 0 Good
Write-Policy Default StripeSize 128KB
ld1 1F4ABC1D 545.91GB Secondary RAID5 5 2 0 Good
Write-Policy Default StripeSize 128KB
with
Serial Number: 07FE18
You should see something like (these names are taken from a Solaris luxadm probe)
Node WWN:206000c0ff07fe18 Device Type:Disk device
Logical Path:/dev/rdsk/c7t600C0FF00000000007FE181F4ABC1D00d0s2
Node WWN:206000c0ff07fe18 Device Type:Disk device
Logical Path:/dev/rdsk/c7t600C0FF00000000007FE185E71495700d0s2
I don't have any clue how this would show up under windows. Putting a fabric on your switch should make things more tidy, but shouldn't fundamentally change anything.

Similar Messages

  • How to configure ntp servers in MDS san switches

           we have five swithes in the fabric ,how to setup  NTP servers in the cisco MDS switches.

    Hi,
    There is an NTP example on page 1-37 (adobe page 53)
    http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_3_x/cookbook/MDScookbook31.pdf
    Regards,
    David

  • Storedge 3510 failover configuration with 1 host

    I people.
    I'm new to the storedge configuration.
    I have a Sun storedge 3510 - 2 controllers with 2 x host port fc and 1x drive port each.
    I want to do a simple configuration - connect 1 host to the storedge with failover.
    It's correct to connect the 2 controllers using the drive port - because i want failover?
    It's possible to use only 1 pci single FC adapter in the machine?
    I will connect the machine with the storedge usinge 1 fibre cable,
    I will use the host port FC1. And to do the failover I will connect the 2 controllers
    using the drive port fc3 e fc2. - THIS IS CORRECT?
    My problem is who to connect the cables and who to configure the storedge. I'm
    already connected to the COM Port.
    Another thing i have in the first controller amber light - this is a hardware problem?
    And wath is the best configuration to use with 3510 storedge, one host, and failover?
    Thank you. I need this help for now.. Please.

    Isn't it wonderful when people respond?
    I, too, am running into the same scenario. We have a single 3510FC that is connected to a single host through two controller cards. The drives are configured as a single logical drive under RAID-5. We want to have this configuration multi-pathed for redundancy, not throughput, even though controller cards NEVER fail. [sarcasm] We will be using Veritas VxVM DMP for redundancy.
    Unfortunately, I can only ever see the logical drive/LUN on one controller. The main connection is channel 0 of the primary controller. Whenever I try to configure it to simultaneously be on channel 5 of the secondary controller, the 3510 won't let me do it. I can't figure out how to get the LUN to be assigned to two host channels when one is on the primary controller and one is on the secondary controller.
    I find this to be absurd. Controllers fail. That's all that there is to it. Yet the design of the 3510 (and the 3310 as well) seem to fight like hell whenever you want to spread the logical drives across physical controllers.
    What's the solution to this one, guys?

  • StorEdge 3510 FC array Configuration

    Hello,
    I'm running Solaris 8 on a Neta 20. I have 3 StorEdge 3510 FC arrays attached; one controller each array. Each has 12x146 drives for a total of 2TB each array. As this if my first time dealing with this array, I need some advise. I configured my first array with one logical drive and 4 partitions. maped the luns, and reset. (oh I changed the seq to ramdom)
    I am now trying to configure the 2nd array, however it will only let me make a logical drive of 512GB max. I've tried everything I could think of to overcome this. Any ideas, I was talking to someone today and they mentioned that solaris will only reconize 1TB. Is this true? If so does anyone have any ideas on a better way to configure the arrays. They will be used for large oracle databases.
    Thanks
    [email protected]

    I presume that by now you have sorted this problem, but in case not, 512Gb is the maximum logical drive size when the i/o optimisation is random.
    On the max disk size, I read somewhere that VxFS might help.
    I found your query when looking for help on directing StorEdge events to the syslogd on our central loghost - which I still haven't found out how to do!?

  • How to configure multiple IP addresses on one NIC?

    Hi,
    I just installed a OVM Server in version 3.2.1 and the according VMManager. Now i wanted to try to configure the Server/Server Pool. Now i come across a problem, which was already a big problem in OVM 2 while configuring the Networks.
    All our OVM Servers have three NICs in them. One is for VMs and Management, the others are for connection to our SAN (Dell PowerVault MD 3220i). My problem is, that due to the network setup, the two NICs for storage need two IP addresses in two different networks each. This shouldn't be a problem, because usually in linux all you have to do is configure something like eth1:1. I remember having huge trouble configuring it in our OVM 2 cluster up to the point where I had to write a shell script to configure the second IP.
    Anyways, I have configured two of the storage networks on eth1 and eth2 of the VM Server. Now i cannot configure any more IP addresses, because eth1 and eth2 are not available anymore for configuration in a third network. I really hoped that it would be possible in OVM 3 to configure multiple IP addresses. And probably it is only my lack of knowledge of how to configure it.
    So any advice is well appreciated.
    Thanks!
    Regards,
    Marek Hubatka

    You should be able to do this by using "VLAN Groups".
    http://docs.oracle.com/cd/E35328_01/E35332/E35332.pdf
    Check out the VLAN groups section. You must great the VLAN groups before you can assign them to interfaces.

  • StorEdge 3510 FC Array Transport/Hard Errors

    We have a StorEdge 3510 connected to a V440 running Solaris 9. /var/messages indicates no errors however iostat -e shows hard and transport errors that increment continuously. If I access the controller on the 3510 I can see transport errors when I look at the Fibre Chanel errors on the drive side. The system contains 2 controllers in redundant mode, however we only have one FC cable path to the HBA on the V440. I have replaced the fibre cable to the HBA, the GBIC and swapped the controllers all of which have not resolved the issue. I have also had a case open with Sun for 2 months and they have no idea.
    What could be causing these errors?

    I presume that by now you have sorted this problem, but in case not, 512Gb is the maximum logical drive size when the i/o optimisation is random.
    On the max disk size, I read somewhere that VxFS might help.
    I found your query when looking for help on directing StorEdge events to the syslogd on our central loghost - which I still haven't found out how to do!?

  • X4200 + RHEL4 32bit  + SG-XPCI1FC-QLC + STOREDGE 3510

    Hi,
    this is my configuration :
    - sun x4200
    + SG-XPCI1FC-QLC
    + STOREDGE 3510
    - RHEL 4 32bit (CENTOS)
    This is an application server that have to run cobol applications connected to oracle
    and for this i must use a 32 bit system (rtsora for cobol don't build on 64).
    But i have a problem with the storedge i can't see any partition mapped to this host!
    If i use the 64 bit os version with kernel 2.6.9-22.ELsmp all work fine on the same at 32
    the qla6312 kernel driver load correctly but i can't see any attached scsi device.
    Any ideas ?

    Hi, thanks for response,
    no i've not compiled a new kernel i installed the 32bit release of RHEL-4 (because i have a cobol application that must work a 32).
    I have 2 server identical: 2 x4200 the first with RHEL-4 64bit the second RHEL-4 32bit the second don't work but if i made a kernel update on RHEL-4 64bit with the new one the controller stop to work!
    I havo no idea.

  • Sun StorEdge 3510

    Dears,
    Good day,
    I need your support to guide me to configure Sun StorEdge 3510. I have 24 Disks and single controller. I is connected to one host. I want to configure it with the most biggest storage. I want to implement RAID 5 on 11 disks on the first enclosure and the same to the second enclosure with two disks spare each one in the same enclosure.
    Can you guide me throw this?
    Thanks a lot.

    Wow, it took me about 5 hours to set mine up from scratch and I'm a pretty strong storage guy. Here's an overview of what I did. Most of the info is in the 3510 documentation.
    Step 1 is connectivity. Get your host to see the 3510 (FC).
    Step 2 - use the cli utilities to setup the IP address on the controller (in-band).
    Step 3 - ssh in, setup the RAID and presentation of the luns
    Step 4 - rescan on the hosts to see the new luns

  • How to configure this setting

    Hi All,
    Just want to ask how to configure the following setting on ASA 5510?
    I can't find the command to configure this command.
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0in 5.4pt 0in 5.4pt;
    mso-para-margin-top:0in;
    mso-para-margin-right:0in;
    mso-para-margin-bottom:10.0pt;
    mso-para-margin-left:0in;
    line-height:115%;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;
    mso-bidi-font-family:"Times New Roman";
    mso-bidi-theme-font:minor-bidi;}
    service-policy global_policy global
    prompt hostname context
    call-home
    profile CiscoTAC-1
      no active
      destination address http https://tools.cisco.com/its/service/oddce/services/DDCEService
      destination address email [email protected]
      destination transport-method http
      subscribe-to-alert-group diagnostic
      subscribe-to-alert-group environment
      subscribe-to-alert-group inventory periodic monthly
      subscribe-to-alert-group configuration periodic monthly
      subscribe-to-alert-group telemetry periodic daily
    Cryptochecksum:ac3594b9bcd390c9d52b2d666f0bb144
    please help....

    What software version are you running on the ASA? You'd need at least 8.2(2) to support smart call-home.
    Thanks,
    Wen

  • Performance to expect from a StorEdge 3510

    Hi all,
    Really need some advice regarding a 3510FC array. We currently have a dual-controller setup with a RAID array + JBOD expansion. Each array has 10 drives, which we've setup as two RAID5 LD's as 8 data, 1 parity + 1 hotspare. The array firmware is 4.15.
    Performance isn't good. We can't seem to get anything better than 65Mb/s, (based upon "mkfile 2g testfile"). Whilst I appreciate this is a far from scientific test, our HDS AMS200 performs this little task in 18secs, as opposed to 32secs on the 3510.
    In the real world, Oracle is running like a dog on it :-(
    I hoping that it's just our RAID5 setup that is not good, but before I consider the pain of -- backup data, reconfigure LD's, restore data -- I want to know if really the 3510 should be performing better.
    If I re-jig the array with RAID1 Luns, + perhaps sequential for redo logs, should I be able to get some decent throughput from this array?
    All help appreciated!

    Here's our config ...
    Sun StorEdge 3000 Family CLI
    Copyright 2002-2005 Dot Hill Systems Corporation.
    All rights reserved. Use is subject to license terms.
    sccli version 2.3.0
    built 2006.03.15.09.49
    build 12 for solaris-sparc
    * inquiry-data
    Vendor: SUN
    Product: StorEdge 3510
    Revision: 415F
    Peripheral Device Type: 0x0
    NVRAM Defaults: 415F 3510 S470F
    Bootrecord version: 1.31H
    Serial Number: 0A7805
    Page 80 Serial Number: 0A78055F4B554305
    Page 83 Logical Unit Device ID: 600C0FF0000000000A78055F4B554305
    Page 83 Target Device ID: 206000C0FF0A7805
    IP Address:
    Page D0 Fibre Channel Address: 05 (id 255)
    Page D0 Node Name: 206000C0FF0A7805
    Page D0 Port Name: 256000C0FFCA7805
    Ethernet Address: 00:C0:FF:0A:78:05
    Device Type: Primary
    unique-identifier: A7805
    controller-name: "R2 3510"
    * network-parameters
    ip-address:
    netmask: 255.255.255.224
    gateway:
    mode: static
    * host-parameters
    max-luns-per-id: 32
    queue-depth: 1024
    fibre-connection-mode: point-to-point
    inband-management: enabled
    * drive-parameters
    spin-up: disabled
    disk-access-delay: 15s
    scsi-io-timeout: 30s
    queue-depth: 32
    polling-interval: 30s
    enclosure-polling-interval: 30s
    auto-detect-swap-interval: disabled
    smart: detect-clone-replace
    auto-global-spare: disabled
    * redundant-controller-configuration
    Redundant Controller Configuration: primary
    Cache Synchronization: enabled
    Host Channel Failover Mode: shared
    Local/Remote Redundant Mode: local
    Write-Through Data Synchronization: disabled
    Secondary RS-232 Port Status: disabled
    Communication Channel Type: Fibre
    * redundancy-mode
    Primary controller serial number: 8104488
    Primary controller location: Lower
    Redundancy mode: Active-Active
    Redundancy status: Enabled
    Secondary controller serial number: 8103724
    * cache-parameters
    mode: write-back
    optimization: random
    sync-period: disabled
    current-global-write-policy: write-back
    * RS232-configuration
    COM1 speed: 9600bps
    * channels
    Ch Type Media Speed Width PID / SID
    0 Host FC(P) 2G Serial 40 / N/A
    1 Host FC(P) N/A Serial N/A / 42
    2 DRV+RCC FC(L) 2G Serial 14 / 15
    3 DRV+RCC FC(L) 2G Serial 14 / 15
    4 Host FC(P) 2G Serial 44 / N/A
    5 Host FC(P) N/A Serial N/A / 46
    6 Host LAN N/A Serial N/A / N/A
    * disks
    Ch Id Size Speed LD Status IDs Rev
    2(3) 0 279.40GB 200MB ld1 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 38528TGW
    WWNN 2000001862363F9C
    2(3) 1 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 0751KPTT
    WWNN 20000014C38511B6
    2(3) 2 279.40GB 200MB GLOBAL STAND-BY SEAGATE ST330000FSUN300G 055A
    S/N 38528FH8
    WWNN 2000001862364997
    2(3) 3 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 385263B5
    WWNN 20000018623649A3
    2(3) 4 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 38528TS7
    WWNN 20000018623647DD
    2(3) 5 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 3852GAAM
    WWNN 20000018623644A8
    2(3) 6 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 38525B67
    WWNN 200000186236463E
    2(3) 7 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 385293LK
    WWNN 20000018623647D4
    2(3) 8 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 38528E2E
    WWNN 2000001862364A4A
    2(3) 9 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 3852FPF2
    WWNN 2000001862364137
    2(3) 10 279.40GB 200MB ld0 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 38525BZE
    WWNN 200000186236438E
    2(3) 11 279.40GB 200MB ld1 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 3852F9C1
    WWNN 2000001862364519
    2(3) 12 279.40GB 200MB ld1 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 22526XFP
    WWNN 20000014C3D8B5CD
    2(3) 13 279.40GB 200MB ld1 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 225280ZR
    WWNN 20000014C3D8B9F4
    2(3) 14 279.40GB 200MB ld1 ONLINE SEAGATE ST330000FSUN300G 055A
    S/N 38527GP1
    WWNN 2000001862364001
    2(3) 15 279.40GB 200MB ld1 ONLINE FUJITSU MAW3300FCSUN300G 1303
    S/N 000629D01NGJ
    WWNN 500000E0126502D0
    2(3) 16 279.40GB 200MB NONE FRMT FUJITSU MAW3300FCSUN300G 1303
    S/N 000629D01NG9
    WWNN 500000E0126501A0
    2(3) 17 279.40GB 200MB ld1 ONLINE FUJITSU MAW3300FCSUN300G 1303
    S/N 000629D01NG0
    WWNN 500000E0126500F0
    2(3) 18 279.40GB 200MB ld1 ONLINE FUJITSU MAW3300FCSUN300G 1303
    S/N 000629D01NGH
    WWNN 500000E0126502B0
    2(3) 19 279.40GB 200MB ld1 ONLINE FUJITSU MAW3300FCSUN300G 1303
    S/N 000629D01NGE
    WWNN 500000E012650210
    * logical-drives
    LD LD-ID Size Assigned Type Disks Spare Failed Status
    ld0 5F4B5543 2.18TB Primary RAID5 9 1 0 Good
    Write-Policy Default StripeSize 32KB
    ld1 07190DF2 2.18TB Secondary RAID5 9 1 0 Good
    Write-Policy Default StripeSize 32KB
    * logical-volumes
    * partitions
    LD/LV ID-Partition Size
    ld0-00 5F4B5543-00 5.00GB
    ld0-01 5F4B5543-01 5.00GB
    ld0-02 5F4B5543-02 5.00GB
    ld0-03 5F4B5543-03 45.00GB
    ld0-04 5F4B5543-04 45.00GB
    ld0-05 5F4B5543-05 300.00GB
    ld0-06 5F4B5543-06 1.79TB
    ld1-00 07190DF2-00 5.00GB
    ld1-01 07190DF2-01 5.00GB
    ld1-02 07190DF2-02 5.00GB
    ld1-03 07190DF2-03 515.00GB
    ld1-04 07190DF2-04 500.00GB
    ld1-05 07190DF2-05 180.00GB
    ld1-06 07190DF2-06 1023.17GB
    * lun-maps
    Ch Tgt LUN ld/lv ID-Partition Assigned Filter Map
    0 40 0 ld0 5F4B5543-00 Primary 210000E08B929600 {tvlp-node-n01p01}
    0 40 0 ld0 5F4B5543-00 Primary 210000E08B92B831 {tvlp-node-n02p01}
    0 40 1 ld0 5F4B5543-01 Primary 210000E08B927C31 {tvlp-node-n03p01}
    0 40 1 ld0 5F4B5543-01 Primary 210000E08B925A02 {tvlp-node-n04p01}
    0 40 2 ld0 5F4B5543-02 Primary 210000E08B927C31 {tvlp-node-n03p01}
    0 40 2 ld0 5F4B5543-02 Primary 210000E08B925A02 {tvlp-node-n04p01}
    0 40 3 ld0 5F4B5543-03 Primary 210000E08B927C31 {tvlp-node-n03p01}
    0 40 3 ld0 5F4B5543-03 Primary 210000E08B925A02 {tvlp-node-n04p01}
    0 40 4 ld0 5F4B5543-04 Primary 210000E08B927C31 {tvlp-node-n03p01}
    0 40 4 ld0 5F4B5543-04 Primary 210000E08B925A02 {tvlp-node-n04p01}
    0 40 5 ld0 5F4B5543-05 Primary 210000E08B927C31 {tvlp-node-n03p01}
    0 40 5 ld0 5F4B5543-05 Primary 210000E08B925A02 {tvlp-node-n04p01}
    1 42 0 ld1 07190DF2-00 Secondary 210000E08B920100 {tvlp-node-n05p01}
    1 42 1 ld1 07190DF2-01 Secondary 210000E08B920100 {tvlp-node-n05p01}
    1 42 2 ld1 07190DF2-02 Secondary 210000E08B920100 {tvlp-node-n05p01}
    1 42 3 ld1 07190DF2-03 Secondary 210000E08B920100 {tvlp-node-n05p01}
    1 42 4 ld1 07190DF2-04 Secondary 210000E08B920100 {tvlp-node-n05p01}
    1 42 5 ld1 07190DF2-05 Secondary 210000E08B920100 {tvlp-node-n05p01}
    4 44 0 ld0 5F4B5543-00 Primary 210000E08B92BC01 {tvlp-node-n01p02}
    4 44 0 ld0 5F4B5543-00 Primary 210000E08B92DB02 {tvlp-node-n02p02}
    4 44 1 ld0 5F4B5543-01 Primary 210000E08B91FDFF {tvlp-node-n04p02}
    4 44 1 ld0 5F4B5543-01 Primary 210000E08B924A03 {tvlp-node-n03p02}
    4 44 2 ld0 5F4B5543-02 Primary 210000E08B924A03 {tvlp-node-n03p02}
    4 44 2 ld0 5F4B5543-02 Primary 210000E08B91FDFF {tvlp-node-n04p02}
    4 44 3 ld0 5F4B5543-03 Primary 210000E08B924A03 {tvlp-node-n03p02}
    4 44 3 ld0 5F4B5543-03 Primary 210000E08B91FDFF {tvlp-node-n04p02}
    4 44 4 ld0 5F4B5543-04 Primary 210000E08B924A03 {tvlp-node-n03p02}
    4 44 4 ld0 5F4B5543-04 Primary 210000E08B91FDFF {tvlp-node-n04p02}
    4 44 5 ld0 5F4B5543-05 Primary 210000E08B924A03 {tvlp-node-n03p02}
    4 44 5 ld0 5F4B5543-05 Primary 210000E08B91FDFF {tvlp-node-n04p02}
    5 46 0 ld1 07190DF2-00 Secondary 210000E08B91EDFF {tvlp-node-n05p02}
    5 46 1 ld1 07190DF2-01 Secondary 210000E08B91EDFF {tvlp-node-n05p02}
    5 46 2 ld1 07190DF2-02 Secondary 210000E08B91EDFF {tvlp-node-n05p02}
    5 46 3 ld1 07190DF2-03 Secondary 210000E08B91EDFF {tvlp-node-n05p02}
    5 46 4 ld1 07190DF2-04 Secondary 210000E08B91EDFF {tvlp-node-n05p02}
    5 46 5 ld1 07190DF2-05 Secondary 210000E08B91EDFF {tvlp-node-n05p02}
    * protocol
    Identifier Status     Port Parameters
    telnet enabled 23 inactivity-timeout=disabled
    http enabled 80 n/a
    https disabled n/a n/a
    ftp enabled 21 n/a
    ssh enabled 22 n/a
    priagent enabled 58632 n/a
    snmp disabled n/a n/a
    dhcp enabled 68 n/a
    ping enabled n/a n/a
    * auto-write-through-trigger
    controller-failure: enabled
    battery-backup-failure: enabled
    ups-ac-power-loss: disabled
    power-supply-failure: enabled
    fan-failure: enabled
    temperature-exceeded-delay: 30min
    * peripheral-device-status
    Item Value status
    CPU Temp Sensor(primary) 52.50C within safety range
    Board1 Temp Sensor(primary) 55.50C within safety range
    Board2 Temp Sensor(primary) 64.00C within safety range
    +3.3V Value(primary) 3.352V within safety range
    +5V Value(primary) 5.019V within safety range
    +12V Value(primary) 12.199V within safety range
    Battery-Backup Battery(primary) 00 Hardware:OK
    CPU Temp Sensor(secondary) 52.50C within safety range
    Board1 Temp Sensor(secondary) 57.50C within safety range
    Board2 Temp Sensor(secondary) 62.00C within safety range
    +3.3V Value(secondary) 3.384V within safety range
    +5V Value(secondary) 5.099V within safety range
    +12V Value(secondary) 12.381V within safety range
    Battery-Backup Battery(secondary) 00 Hardware:OK
    * enclosure-status
    Ch Id Chassis Vendor/Product ID Rev PLD WWNN WWPN
    2 124 0A7805 SUN StorEdge 3510F A 1080 1000 204000C0FF0A7805 214000C0FF0A7805
    Topology: loop(a) Status: OK
    3 124 0A7805 SUN StorEdge 3510F A 1080 1000 204000C0FF0A7805 224000C0FF0A7805
    Topology: loop(b) Status: OK
    Enclosure Component Status:
    Type Unit Status FRU P/N FRU S/N Add'l Data
    Fan 0 OK 371-0108 GK0XC2 --
    Fan 1 OK 371-0108 GK0XC2 --
    Fan 2 OK 371-0108 GK0XC5 --
    Fan 3 OK 371-0108 GK0XC5 --
    PS 0 OK 371-0108 GK0XC2 --
    PS 1 OK 371-0108 GK0XC5 --
    Temp 0 OK 371-0531 0A7805 temp=30
    Temp 1 OK 371-0531 0A7805 temp=28
    Temp 2 OK 371-0531 0A7805 temp=31
    Temp 3 OK 371-0531 0A7805 temp=30
    Temp 4 OK 371-0531 0A7805 temp=31
    Temp 5 OK 371-0531 0A7805 temp=30
    Temp 6 OK 371-0532 HL12LM temp=37
    Temp 7 OK 371-0532 HL12LM temp=41
    Temp 8 OK 371-0532 HL12QD temp=37
    Temp 9 OK 371-0532 HL12QD temp=38
    Temp 10 OK 371-0108 GK0XC2 temp=30
    Temp 11 OK 371-0108 GK0XC5 temp=25
    Voltage 0 OK 371-0108 GK0XC2 voltage=5.110V
    Voltage 1 OK 371-0108 GK0XC2 voltage=11.750V
    Voltage 2 OK 371-0108 GK0XC5 voltage=5.020V
    Voltage 3 OK 371-0108 GK0XC5 voltage=11.520V
    Voltage 4 OK 371-0532 HL12LM voltage=2.480V
    Voltage 5 OK 371-0532 HL12LM voltage=3.250V
    Voltage 6 OK 371-0532 HL12LM voltage=5.000V
    Voltage 7 OK 371-0532 HL12LM voltage=12.120V
    Voltage 8 OK 371-0532 HL12QD voltage=2.500V
    Voltage 9 OK 371-0532 HL12QD voltage=3.300V
    Voltage 10 OK 371-0532 HL12QD voltage=5.050V
    Voltage 11 OK 371-0532 HL12QD voltage=12.240V
    DiskSlot 0 OK 371-0531 0A7805 addr=0,led=off
    DiskSlot 1 Absent 371-0531 0A7805 addr=1,led=off
    DiskSlot 2 Absent 371-0531 0A7805 addr=2,led=off
    DiskSlot 3 OK 371-0531 0A7805 addr=3,led=off
    DiskSlot 4 OK 371-0531 0A7805 addr=4,led=off
    DiskSlot 5 OK 371-0531 0A7805 addr=5,led=off
    DiskSlot 6 OK 371-0531 0A7805 addr=6,led=off
    DiskSlot 7 OK 371-0531 0A7805 addr=7,led=off
    DiskSlot 8 OK 371-0531 0A7805 addr=8,led=off
    DiskSlot 9 OK 371-0531 0A7805 addr=9,led=off
    DiskSlot 10 OK 371-0531 0A7805 addr=10,led=off
    DiskSlot 11 OK 371-0531 0A7805 addr=11,led=off
    * SES
    Ch Id Chassis Vendor/Product ID Rev PLD WWNN WWPN
    2 124 0A7805 SUN StorEdge 3510F A 1080 1000 204000C0FF0A7805 214000C0FF0A7805
    Topology: loop(a)
    3 124 0A7805 SUN StorEdge 3510F A 1080 1000 204000C0FF0A7805 224000C0FF0A7805
    Topology: loop(b)
    * port-WWNs
    Ch Id WWPN
    0 40 216000C0FF8A7805
    1 42 226000C0FFAA7805
    4 44 256000C0FFCA7805
    5 46 266000C0FFEA7805
    * inter-controller-link
    inter-controller-link upper channel 0: connected
    inter-controller-link lower channel 0: connected
    inter-controller-link upper channel 1: connected
    inter-controller-link lower channel 1: connected
    inter-controller-link upper channel 4: connected
    inter-controller-link lower channel 4: connected
    inter-controller-link upper channel 5: connected
    inter-controller-link lower channel 5: connected
    * battery-status
    Upper Battery Type: 1
    Upper Battery Manufacturing Date: Fri Jun 16 00:00:00 2006
    Upper Battery Placed In Service: Tue Aug 8 09:27:53 2006
    Upper Battery Expiration Date: Thu Aug 7 09:27:53 2008
    Upper Battery Expiration Status: OK
    Lower Battery Type: 1
    Lower Battery Manufacturing Date: Fri Jun 16 00:00:00 2006
    Lower Battery Placed In Service: Tue Aug 8 09:27:52 2006
    Lower Battery Expiration Date: Thu Aug 7 09:27:52 2008
    Lower Battery Expiration Status: OK
    Upper Battery Hardware Status: OK
    Lower Battery Hardware Status: OK
    * sata-router
    no sata routers found
    * sata-mux
    0 mux boards found
    * host-wwn-names
    Host-ID/WWN Name
    210000E08B91EDFF tvlp-node-n05p02
    210000E08B91FDFF tvlp-node-n04p02
    210000E08B925A02 tvlp-node-n04p01
    210000E08B927C31 tvlp-node-n03p01
    210000E08B924A03 tvlp-node-n03p02
    210000E08B92DB02 tvlp-node-n02p02
    210000E08B92BC01 tvlp-node-n01p02
    210000E08B92B831 tvlp-node-n02p01
    210000E08B920100 tvlp-node-n05p01
    210000E08B929600 tvlp-node-n01p01
    * FRUs
    7 FRUs found in chassis SN#0A7805 at ch 2 id 124
    Name: FC_CHASSIS_BKPLN
    Description: SE3510 FC Chassis/backplane
    Part Number: 371-0531
    Serial Number: 0A7805
    Revision: 01
    Initial Hardware Dash Level: 01
    FRU Shortname:
    Manufacturing Date: Sun Jul 16 05:25:36 2006
    Manufacturing Location: Suzhou,China
    Manufacturer JEDEC ID: 0x0301
    FRU Location: FC MIDPLANE SLOT
    Chassis Serial Number: 0A7805
    FRU Status: OK
    Name: FC_RAID_IOM
    Description: SE3510 I/O w/SES RAID FC 2U
    Part Number: 371-0532
    Serial Number: HL12LM
    Revision: 01
    Initial Hardware Dash Level: 01
    FRU Shortname:
    Manufacturing Date: Wed Jul 5 12:11:49 2006
    Manufacturing Location: Suzhou,China
    Manufacturer JEDEC ID: 0x0301
    FRU Location: UPPER FC RAID IOM SLOT
    Chassis Serial Number: 0A7805
    FRU Status: OK
    Name: BATTERY_BOARD
    Description: SE351X Hot Swap Battery Module
    Part Number: 371-0539
    Serial Number: GP15BJ
    Revision: 01
    Initial Hardware Dash Level: 01
    FRU Shortname:
    Manufacturing Date: Thu Jul 6 03:25:30 2006
    Manufacturing Location: Suzhou,China
    Manufacturer JEDEC ID: 0x0301
    FRU Location: UPPER BATTERY BOARD SLOT
    Chassis Serial Number: 0A7805
    FRU Status: OK
    Name: AC_POWER_SUPPLY
    Description: SE3XXX AC PWR SUPPLY/FAN, 2U
    Part Number: 371-0108
    Serial Number: GK0XC5
    Revision: 01
    Initial Hardware Dash Level: 01
    FRU Shortname:
    Manufacturing Date: Mon May 22 08:45:16 2006
    Manufacturing Location: Irvine California, USA
    Manufacturer JEDEC ID: 0x048F
    FRU Location: RIGHT AC PSU SLOT #1 (RIGHT)
    Chassis Serial Number: 0A7805
    FRU Status: OK
    Name: AC_POWER_SUPPLY
    Description: SE3XXX AC PWR SUPPLY/FAN, 2U
    Part Number: 371-0108
    Serial Number: GK0XC2
    Revision: 01
    Initial Hardware Dash Level: 01
    FRU Shortname:
    Manufacturing Date: Mon May 22 08:53:42 2006
    Manufacturing Location: Irvine California, USA
    Manufacturer JEDEC ID: 0x048F
    FRU Location: AC PSU SLOT #0 (LEFT)
    Chassis Serial Number: 0A7805
    FRU Status: OK
    Name: FC_RAID_IOM
    Description: SE3510 I/O w/SES RAID FC 2U
    Part Number: 371-0532
    Serial Number: HL12QD
    Revision: 01
    Initial Hardware Dash Level: 01
    FRU Shortname:
    Manufacturing Date: Wed Jul 5 15:16:42 2006
    Manufacturing Location: Suzhou,China
    Manufacturer JEDEC ID: 0x0301
    FRU Location: LOWER FC RAID IOM SLOT
    Chassis Serial Number: 0A7805
    FRU Status: OK
    Name: BATTERY_BOARD
    Description: SE351X Hot Swap Battery Module
    Part Number: 371-0539
    Serial Number: GP15GW
    Revision: 01
    Initial Hardware Dash Level: 01
    FRU Shortname:
    Manufacturing Date: Thu Jul 6 05:26:03 2006
    Manufacturing Location: Suzhou,China
    Manufacturer JEDEC ID: 0x0301
    FRU Location: LOWER BATTERY BOARD SLOT
    Chassis Serial Number: 0A7805
    FRU Status: OK
    * access-mode
    access-mode: inband
    * controller-date
    Boot time : Fri Jan 5 10:20:15 2007
    Current time : Thu Feb 8 10:25:36 2007
    Time Zone : GMT
    * disk-array
    init-verify: disabled
    rebuild-verify: disabled
    normal-verify: disabled
    rebuild-priority: normal

  • StorEdge 3510 disk array & SunMC

    Hi
    I have a question regarding Sun StorEdge 3510 & SMC. I want to have notifications about hdd problems, cache or controller faults. I know that I can install StorADE and send messages to SMC. Is there any other way to have 3510 notifications in SMC withouht hiring StorADE?
    Regards
    Paul

    Hello,
    You can use following way to monitores 3510 Raid array :
    Install packages on the 3510 connected server
    system SUNWsccli Sun StorEdge(tm) 3000 Family CLI
    system SUNWscsa Sun StorEdge(tm) Diagnostic Reporter daemon
    system SUNWscsd Sun StorEdge(tm) Configuration Service Agent
    application SUNWscsu Sun StorEdge(tm) Configuration Service Console
    system SUNWscui Sun StorEdge(tm) Diagnostic Reporter console
    This provide ssconsole binary. Start it and assign your 3510 Raid ctrl to send alarms to one Solaris host.
    Exact procedure (account creation, etc...) to do so should be present somewhere on docs.sun.com
    Now, each time an event occurs on the 3510, a log will appears with SUNWscsd... blablabla into /var/adm/messages :
    /var/adm/messages.0:Jun 26 15:48:11 PNMSSS082 SUNWscsdMonitor[522]: [ID 163373 daemon.error] [SUNWscsd 0x030B2007:0x00FFFF00 Informational] <rctrl2041> Logical Drive 0(ID=6327904A, RAID 5), Rebuild Completed. Informational message. Replace defective drive with new drive. (Mon Jun 26 15:22:48 2006) {Unique ID#: 07e60a}
    Use SMC agent log file scanning to monitor trap with this string "SUNWscsd"
    Hope this will help.
    Regards,
    Damien

  • How to configure oracle listener profile for multiple oracle database

    Hi,
    I am going to install solution manager system in the same server of ERP EHP4 on Windows. Both DB are oracle.
    I'd like to know how to configure listener in this kind of envirnmonent.
    a. use two listener and different ports
    b. use same listener but different ports
    c. use same listener and same port
    Which is the correct mothed?
    And, after installation, there seem three set of profiles of listten, one for ERP, one for SLM, and the other for OS?(%windir%system32), which one is functional?
    Please advise.
    Thanks a lot.
    Regards,
    Alex

    Hi,
    standard installation is creating new configs for listener for each instance.
    I would recommend to use one listener per each instance.
    YOU CAN NOT HAVE one port number for two differnet systems!
    If you want to use one listener than you must adapt tnsnames.ora, listener.ora and ensure that both systems will use different port numbers.
    For example PORT= 15<system number>
    Peter

  • How to configure one TREX host with multiple index servers ?

    Hi All,
    Does anyone know how to configure TREX on the one host,
    with multiple index servers ?
    Reason for this is to make better use of resources available on the host server(4 Gig, 4 Processor, Windows2003), to improve the search performance of
    our KM content for portal users.
    I am using TREX 7 and have not been able to do this,
    despite reading the Single and Distributed install
    documentation.
    Any help would be appreciated.
    Regards,
    Andres

    Hi Andres,
    To make use of the RAM a Server provides you have to run two indexserver processes (each can then consume 2 GB);
    Proceed like this:
    1. Go to TREXdeamon.ini; check if section [indexserver2] is there (it is already provided, but not active in standard installation)
    2. In TREXdeamon.ini go to
    [daemon]
    references sections below
    programs=nameserver,preprocessor1,indexserver1,queueserver,alertserver
    and add indexserver2 here. Restart TREX; second porcess is then started; can be checked in TREX monitor in Portal as well
    3. To distribute existing indexes to the new process, start TREXadmintool and go to Index: Landscape
    Go to the last two columns and move the indexes (move master here/secondary mouse click)
    If you don't distribute the indexes the new index server process will be regarded when an new index is created.
    Hope this helps!
    cheers
    Bettina

  • How to configure request manager service for multiple website in one web application

    I have set up sp 2013 as below:
     web application : wa1
    site collection : sc1
    sp site: site1, site2
    I used 2 WFE, 1 APP, how can I use request manager service to control  site1 to wfe1, site2 to wfe2?
    Awen

    That's not what i'd describe as load balancing.
    A better description would be load-isolation. In your description then if the load on site1 was large (and growing) but site2 was quiet then site1 would struggle and eventually become unable to handle the number of users but site2 would still be ok. That's
    fine from a QOS point of view but it's not the norm for load balancing. It would work in simple scenarios but the out of the box load balancing tools are much better suited than that sort of approach.
    This article shows how to configure the RMS and may help show how your request is difficult to configure:
    http://www.harbar.net/articles/sp2013rm2.aspx

  • How to configure 3 different members under a single Month column

    Hi SAP Gurus,
      My client requirement is to show the report in following format, where under a Month column 3 different columns having
    1) Quantity (Number of unit ) of a product,
    2) its rate (Amount per unit), and
    3) Total (amount)    will appear in a single report.
       I have Month as a Time Dim, while Qty, Rate and Total are members of account dim.
    Que: How to configure such scenario in a single report?
    Jan.2011
    Product Category:            Qty (Input)   Rate (Input)   Total (Output)                    
    Product 1                                               
    Product 2                                             
    Product 3                                             
    Product 4                                             
    Group1                                             
         Where: Total = Qty X Rate                                        
    Thanks and Regards,
    SouarbhD

    Hi,
    Use an EVDRE to create your input schedule. You need to have one row with products and 2 columns with time and account. Choose the memberset options as per the requirement. For the accounts, is total calculated with a dimension formula? If yes, then you just need to enter the values for quantity and rate and send the data. The total will be calculated by the system and will be displayed automatically.
    Hope this helps.

Maybe you are looking for