How to determine the positioning order when using tab key?

Hallo,
in my jspx-page i want to define the order which the cursor jumps when the user is using the tab key.
i don't know how to? in html there i can use tabindex. which way i must go?
Any help is appreciated.

I found that tabindex is not applicable. But i think it is an important point for better handling.
Is there no easy way to do it?

Similar Messages

  • How to save the value from JTextFormattedField using TAB key in lostFocus

    Can you, please help me with this problem:
    I want to have saved new value in JTextFormattedField after I use TAB kye.
    I tried with focusLost, then setting setFocusTraversalKeys etc.
    It looks simple, but !?
    Thanks

    I also tried the JFormattedTextField for the IPAddress Object which I created but it would't work that well I have a bad experience with these TextFields it showed me the formate 0.0.0.0 but when I entered the text in it, it jumps of after tow digits in each column

  • How to determine the correct moment when Word has finished to write to a docx file

    Hello,
    we are currently passing a document to Microsoft Word for editing and want to take back the changed/saved document when editing is finished. But it seems we have issues to determine the correct moment when Word has for sure saved all changes and
    it is save to take back the file.
    To pass the document to Word we use ShellExecuteEx with the file name. Then we use the Running Objects Table and a File Moniker to wait for the file to be closed.
    Sample code:
    HRESULT hRes = S_OK; 
    CComPtr<IMoniker> spIMoniker; 
    CComPtr<IRunningObjectTable> pRT; 
    hRes = GetRunningObjectTable(0, &pRT); 
    if (FAILED(hRes))
       TWTHROW1(TWERR_ANY_ERROR, hRes, _T("GetRunningObjectTable failed."));
    hRes = ::CreateFileMoniker(m_strTempFilename.AllocSysString(), &spIMoniker);
    if (FAILED(hRes))
       TWTHROW1(TWERR_ANY_ERROR, hRes, _T("CreateFileMoniker failed."));
    while (S_OK == pRT->IsRunning(spIMoniker) && !m_bShutdown)
       Sleep(500);
       continue;
    So we wait for the file to be removed from the Running Objects Table and additionally wait until we can get exclusive access to the file before we take over the changed file. But still it seems to happen that we take the file too early. Hence it
    seems the file is removed from the Running Objects Table by Microsoft Word before saving the file has completed.
    Is this behaviour of Microsoft Word by design? What is the best practice to identify the moment in time when writing the file has completed. Some other applications like Winzip seem to do the same thing.
    Thanks,
    Wolfgang

    Hi WolfGang,
    Thanks for posting in MSDN forum.
    Based on the description, you are developing application with Windows API. I would like to move it to
    General Windows Desktop Development Issues forum.
    The reason why we recommend posting appropriately is you will get the mostqualified pool of respondents, and other partners who read the forums regularly can either share their knowledge
    or learn from your interaction with us.
    Thanks for your understanding.
    Regards & Fei
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • How to know the sales order closed using right click menu -Close ???

    I have an sales order with ten item, I have copied the same to delivery and before adding the Delivery I have deleted some items. After adding the Delivery, I manually closed the sales order by using the "right click menu close".
    The Open Quantity of those lines are already closed while i Close it manually.
    Now i need  a report regarding the sales orders which i  have closed manually. Any Options??

    Check the below result
    DocNum     DocDate     CardCode     CardName     Row#     ItemCode     Dscription     Price     Quantity     LineTotal
    2     2012-02-04 00:00:00.000     ED-C-102     AI HUDHA BOOK STALL     2     1010          150.000000     10.000000     1500.000000
    3     2012-02-04 00:00:00.000     ED-C-103     AL AMEEN ENGLISH SCHOOL-MANKADA     2     1011     ZINC ROD HIGH GRADE PURE ZINC 140 X 9 MM     59.790000     10.000000     597.900000
    this is the result i get while i execute your query
    but look at the db result
    DocEntry     LineNum     TargetType     TrgetEntry     LineStatus     ItemCode     Quantity     OpenQty
    1     0     15     2     C     1010     10.000000     0.000000
    2     0     15     3     C     1010     10.000000     0.000000
    2     1     -1     NULL     C     1010     10.000000     0.000000
    3     0     15     4     C     1010     1.000000     0.000000
    3     1     -1     NULL     C     1011     10.000000     0.000000
    3     2     15     4     C     1012     15.000000     0.000000
    3     3     15     4     C     1013     20.000000     0.000000
    4     0     15     5     O     1010     10.000000     5.000000
    See the last line data...it have open quantity of 5 and it also have the target type 15, If I close the sales order with docentry 4 manually using right click, the open quantity will be Zero..
    I need that last line result also as my output..
    Hope you understand my problem.
    Thank You

  • How to Select the Current Row When Using af:iterator?

    Hello all,
    I encounter the following problem when using af:iterator to display data from
    a View Object:
    When trying to display the content of a row via a popup, only the first row is
    returned no matter which row is selected. So a selection of the current row
    should exist or some other method which should allow the access to the
    current row.
    The af:table has a selectionListener attribute which permit to achieve this.
    Does anyone know about some similar attribute or some method for
    selecting the current row when the af:iterator is used?
    Thank you,
    Mirela

    I would be interested in the answer to this basic question as well. I cannot get the selected row value of an attribute in an iterator for a view if I simply set-up a attribute binding to the iterator. It seems that this should be possible. I've had no other option but to obtain the current row and the related attributes programmatically. This works fine, but if there is a more elegant option, then I'd certainly like to use it.
              <af:table value="#{bindings.CompaniesView1.collectionModel}"
                            var="row"
                            rows="#{bindings.CompaniesView1.rangeSize}"
                            emptyText="#{bindings.CompaniesView1.viewable ? 'No data to display.' : 'Access Denied.'}"
                            fetchSize="#{bindings.CompaniesView1.rangeSize}"
                            selectedRowKeys="#{bindings.CompaniesView1.collectionModel.selectedRow}"
                            rowBandingInterval="0" id="tCompanies"
                            summary="Companies"
                            width="100%"
                            rowSelection="single"
                            binding="#{CompanyBackingBean.companiesTable}">Page Def:
        <attributeValues IterBinding="CompaniesView1Iterator" id="Id">
          <AttrNames>
            <Item Value="Id"/>
          </AttrNames>
        </attributeValues>I should be able to get the Id attribute value of the current selected row using "#{bindings.Id}", right? Well, it doesn't work for me. Any ideas?
    Thanks

  • How to resolve the error -1073807339 when using Agilent LAN/GPIB Gateway (E5810A)?

    Dear Sir/Madam,
    Appreciate that you could advise me on the following error occur when connect power meter E4419B to computer via E5810A LAN/GPIB Gateway(remote interface) & run with Labview: 
    -1073807339
    VISA Write in E4419_read_power.vi
    I have added 5s timeout to Labview program but the result as previous.
    There no error occurs when the power meter to computer via USB/GPIB interface(82357B).
    Is it related to E5810A driver or the program I wrote?
    How to resolve it?
    Attachments:
    E4419_read_power.vi ‏16 KB

    Hi.
    I'm experiencing the same problem when connecting a laser controller (New Focus Vortex TLB-6000) via the Agilent E5810A to a PC.  
    There are no problems when connected through a regular serial port, but timeouts arise every few seconds through the E5810A.  I have another controller (SRS LDC501) which works very well with a second Agilent console.
    Have you managed to find a solution to this problem?
    Thanks,
    Orel.

  • How to determine the position of a word in a line

    hello
    i want to know the position of a word on which caret is at present or the position of the selected word in a line displayed in the JEditorPane. for example, if this line is displayed
    Java is an Object oriented Language.
    if i select "an" then its position i get must be 3. Select Java postion must be 1 and so on.
    thanx in advance
    -Ashish

    Hi,
    you can use a StringTokenizer to break the result of getText() of JEditorPane into words and simply count them until the caret postion is passed. Add a method like this in your JEditorPane subclass:
    public int whichWord() {
    String delimiters = "\n\t "; // checking for new line, tab and space as word breaks
    StringTokenizer st = new StringTokenizer(getText(),delimiters,true);
    int pos = getCaretPosition();
    int count = 0;
    int len = 0;
    while ((len<pos)&st.hasMoreTokens())
    String s = st.nextToken();
    len += s.length();
    if (delimiters.indexOf(s)==-1) { count++; }
    return count;
    }Hope this helps - not tested, coded on the fly into this textbox.
    greetings Marsian

  • How to determine the position in code after pause/abort

    Hi there.
    I've been searching for this for quite a while now, but I didn't find a solution, although I might just have looked in the wrong direction.
    Problem is: I'm trying to find a way to see where my program was (i.e. which part of the code it was execution) the moment I click on pause or abort. (Like the "pause" button present in most modern IDEs, when pressed, it halts the tread and jumps to the code-line or ASM-instruction the CPU was executing).
    The reason: I'm using LabView to control a few instruments to do some measurements on OPVCs. During long measurements involving multiple parameter-sweeps and hence numerous reconfigurations of both function generators and scopes, the program sometimes stops, or better "stalls".
    That is, the front panel's still responsive, but the measurement stops. I don't know whether the problem is related to my program or the scope (it's a LeCroy 434 Wavesurfer) or the FG (a Tabor series) - but I cannot find out either because I don't know what the program did last. FYI: when watching the program's execution using the Execution Highlighting tool, the error doesn't show up, so I guess it's some sort of timing issue.
    I'm currently installing the Execution Trace toolkit in the hope it will help, but still, any help would be great!
    Thanks in advance
    Alex

    AlexHofi wrote:
    LV_Pro wrote:
    Do you have any other means to stop your program currently?
    Yes, in theory... in the last few minutes I reviewed some code I wrote months ago when starting with the development and saw some possible dead-locks with the UI. I have two "Stop"-Buttons, one that stops the measurement and one that exits the wohle program, the latter via an event, the first get's polled in the measurement loop via reference. I read elsewhere that this might not be the best way of doing it, as accessing the UI outside the main event loop might cause some problems.
    I've got some spare lab-time today and will look into this again, unfortunately I cann't test the OutputDebugString-Thingy on my development machine as it's on linux.
    Anyway, it's quite exciting that I finally found a board where peopple really try to helpt, even if the questions ask might not be as constructive as theay could/should be. Thank you very much for that!
    Generally it is best to keep UI elements out of your processing code. Not only will a property node force execution to the UI thread it also tightly couples your UI and processing tasks. The prefered method is to use some type of messaging to the processing tasks. This can be implemented using queues, notifiers or user events. Your processing tasks now have a defined interface for interacting with them which makes reuse of the code easier. It is also more maintainable since you can completely change the UI without requiring a change to the processing code.
    Mark Yedinak
    "Does anyone know where the love of God goes when the waves turn the minutes to hours?"
    Wreck of the Edmund Fitzgerald - Gordon Lightfoot

  • How to switch the keyboard language when using a bluetooth keyboard?

    When using the on-screen keyboard I have the little globe to switch languages, but when using a bluetooth keyboard the on-screen keyboard is hiden.
    I want to be able to write in different languages using the bluetooth keyboard, also the auto-correct gets in the way if I write in a different language than english and it tries to change the words to the closest similar english word.
    Help!

    I see that now Tom, I'm sorry to confuse things.  I think my problem might have been that I had the keyboard too far away from the phone, and so when I looked back from the keyboard to the phone, the screen indication of the languages had already disappeared from the screen.  Because I have more than one language with Roman characters installed, I thought that no change was occurring from that sequence of commands, since I wasn't getting Korean.  But now that I see your correction, and watch the screen closely, I see that you're right.  I apologize.  (And of course, I'm grateful to have a simpler way of switching languages!)

  • How to get the displayed message when using FM:  ABAP4_CALL_TRANSACTION

    Hi, 
    I am calling FM ABAP4_CALL_TRANSACTION from MS-Excel.  This FM works perfectly for me except the system messages that SAP returns are not always understandable or intituative.  My question is there another FM or Table that I can use to convert the data from MESS_TAB to a more meaningful message for the users?
    Examples listed below:
    Normal T-Code Message
    FM Message in MESS_TAB
    Real Meaning
    Fill in all required entry fields
    COBL-RMVCT        
    Field COBL-RMVCT is a required field
    Document 400000000 was posted in 130
    4000000000 130
    Document 400000000 was posted successfully
    Thanks for your Help

    Hi Karim,
    when you have the parameter to generate the message, you can use the following RFC function module:
    BAPI_MESSAGE_GETDETAIL
    The module has the following interface:
    *"*"Lokale Schnittstelle:
    *"  IMPORTING
    *"     VALUE(ID) LIKE  BAPIRET2-ID
    *"     VALUE(NUMBER) LIKE  BAPIRET2-NUMBER
    *"     VALUE(LANGUAGE) LIKE  BAPITGA-LANGU DEFAULT SY-LANGU
    *"     VALUE(TEXTFORMAT) LIKE  BAPITGA-TEXTFORMAT
    *"     VALUE(LINKPATTERN) LIKE  BAPITGA-LINKMASK OPTIONAL
    *"     VALUE(MESSAGE_V1) LIKE  BAPIRET2-MESSAGE_V1 OPTIONAL
    *"     VALUE(MESSAGE_V2) LIKE  BAPIRET2-MESSAGE_V2 OPTIONAL
    *"     VALUE(MESSAGE_V3) LIKE  BAPIRET2-MESSAGE_V3 OPTIONAL
    *"     VALUE(MESSAGE_V4) LIKE  BAPIRET2-MESSAGE_V4 OPTIONAL
    *"  EXPORTING
    *"     VALUE(MESSAGE) LIKE  BAPIRET2-MESSAGE
    *"     VALUE(RETURN) LIKE  BAPIRET2 STRUCTURE  BAPIRET2
    *"  TABLES
    *"      TEXT STRUCTURE  BAPITGB OPTIONAL
    Best regards
    Thomas

  • How do determine the work orders for a sales order?

    I'm forced to calculate our costs by sales order.  So for a given sales order number, how is this linked to the work order that created the items on the sales order?
    Thanks

    Hi,
    Check this:
    Re: Open Production Orders List with a Field from Sales Order
    Thanks,
    Gordon

  • How do I set DNS order when using a VPN?

    Hi, to increase my data security when using local hotspots and WI-FI, I've set up a PPTP server on my home network and connect to it using my MBP OSX 10.5.4. So far, everything's fine.
    But I found that the VPN connection will still try to resolve host names using the DNS of the underlying WLAN/UMTS connection. Which is bad for two reasons:
    First, my local network at home *doesn't permit DNS* access other than the internal DNS. So, all connection attempts time out three times, keeping me waiting in the meantime until it proceeds to connect to my internal DNS.
    Second, internal hosts are *not visible* when using external DNS. Obviously... so just adjusting the firewall and allowing external DNS isn't even a solution.
    I've tried all kinds of settings, set my VPN as the default connection, manually added DNS settings to it or read about the inner workings of the resolv library of OSX. After a very easy initial setup, I'm stuck due to a tiny detail that keeps me from using the VPN. Is there anything I can do to actually use VPN in a proper way?
    Regards,
    Christian
    p.s.: I'm currently about to try IPsec, just wondering if there's any difference. Will keep you updated...

    fredawaters wrote:
    I get to the screen where I am to put in mail server and I put in the IP address and that doesn't work.  I get the error message: Cannot connect to email server or invalid server name.  Please verify server name.  Any suggestions?
    Please answer OzBBerry42's earlier questions -- we need that information to proceed.
    Occam's Razor nearly always applies when troubleshooting technology issues!
    If anyone has been helpful to you, please show your appreciation by clicking the button inside of their post. Please click here and read, along with the threads to which it links, for helpful information to guide you as you proceed. I always recommend that you treat your BlackBerry like any other computing device, including using a regular backup schedule...click here for an article with instructions.
    Join our BBM Channels
    BSCF General Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • How to stop a while loop when using tab control

    How do you use a tab contol to stop what is happening on one tab when you switch to another tab?  In the test example I attached, I have a while loop nested inside a case structure controlled by the tab control.  When I tab to page two the elapsed timer starts but when I switch to another tab it does not stop.  I can't come up with an easy way to stop or exit the while loop when I change tabs. 
    Thank you
    Danny
    Attachments:
    tab control.vi ‏24 KB

    I played with it a little more and came up with this fix.  This fixes it but is not tied to the changing tabs as I was looking for.  Is this just too many nested loops and a bad idea?
    Danny
    Attachments:
    tab control fix maybe.vi ‏26 KB

  • Highlight appears over rewind button when using Tab key

    I am using Captivate 4 and publishing with Actionscript 3.  When the user enters text, they can use the tab key as a shortcut key to move to the next field.  However, when they use the tab key, a highlight appears over the rewind key in the control bar.  I have tried the no_yellow_tab widget and that did not work with captivate 4/actionscript 3.  I also tried adding so.addParam("seamlesstabbing", "false"); to the html and this did nothing as well.  Any ideas?
    Thank you,
    Claudia

    Hi there
    You might try inserting a Click Box object at the top of your timeline. Configure it to do nothing if clicked and so there is no visible indication.
    I've seen it before where focus shifts instead to the hidden object and prevents it from reaching the playback controls. My thought is that after Tab is pressed, focus will then be placed on the hidden Click Box which, of course, the user will not see and will do nothing if they click.
    Cheers... Rick
    Helpful and Handy Links
    Captivate Wish Form/Bug Reporting Form
    Adobe Certified Captivate Training
    SorcerStone Blog
    Captivate eBooks

  • How to display the master TOC when using Context help in a merged document

    I use Robohelp 10. I have created a large Merged Webhelp project and I have set out the project master with nothing in it other than merged projects place markers.
    This is the layout of the generated projects etc.
    Generate
              Master.htm
                   Redirect.htm  (Home page is a redirect to Project 1 Home Page - not in TOC)
    mergedProjects
              Project1
                  Home Page.htm
              Project2
                   Redirect.htm  (Home page is a redirect to Project 1 Home Page - not in TOC)
              Project3 etc.
                    Redirect.htm  (Home page is a redirect to Project 1 Home Page - not in TOC)
    I can get the help to work great when I call up the master page, which shows the TOC for the whole project and the default home page. And from the breadcrumb the home link goes to the home page and shows the Main TOC
    However when I call a page using context help ID I get a single frame with the selected page. The link to show the TOC shows the TOC but it is the top of the merged project and not the master TOC. The home link in the does display the home page but again the displayed TOC is the one of the current merged project.
    The question is :
    How can I get the Master TOC to show all the time regardless of what page I call using a context ID or how can I create a link that will take me back to the Master TOC?
    I remember when I created a previous help file for chm output I had to modify all the ali files in order for the redirect to work throught the master chm. Surely this is not the case with webhelp?
    TonyC

    I am sorry that I didn't get back to all you guys that took to answering my very promptly. Unfortunately I was not in a position to answer to the suggestions made. as I was away from my computer which had Robohelp on.
    Anyway, I did try a couple of scripts mentioned, but didn't really have any success i achieving what I need to do.
    I set up a redirect which redirected to the main home page. I tried setting the home page in a  main sub-project - so the redirect when from any sub project
    Generate
         Master-project.htm (Home Page = Help_Welcome.htm)
    merged Projects
    SubProject1
                [Home Page =  home_redirect.htm (a redirect see below) ]
         SubProject 2
                [Home Page =  home_redirect.htm (a redirect see below) ]
         SubProject 3
                [Home Page =  home_redirect.htm (a redirect see below) ]
    home_redirect.htm  (a redirect use by sub-topics)
    <!--
       window.location="../../ Help_Welcome.htm ";
    //-->
    //]]></script>
    This setup works fine as long as I call the master page. The TOC is as I would want. However if I call an ID from my application I get the required page to display and I can get the TOC to show. The problem is that the TOC is from the current sub-project and not the master project as I would want.

Maybe you are looking for

  • Voice memos not playing and not synced

    some of my voice memos are not playing and are not being synced to itunes, what can I do?

  • Interactive report question

    Hello, Is it possible dont include column in IR (simply dont show column on page, but in SELECt it is), but to have opportunnity search data by this column (it means to have this columns list in built in IR's search region). Thank you!

  • Strange Undo problem

    Hi, I'm using LR 2.2 and recently I've found that when I attempt to "Undo" something (Undo creative preset, Undo adjustment brush, Undo Grad filter) in Develop I get kicked out of the photo I'm working on, kicked out of the photo download group I'm w

  • GRN Date or MB1C date should be considered for batch

    Dear All, Our customer wants to include GRN date (MIGO) and Goods posting date (MB1C) as a Characteristic for a batch. And he wants the system to pick up these dates automatically for batch. So in batches will be sorted out based on GRN (MIGO) or Goo

  • Adobe Reader 8.1.3

    Last year I upgraded from XP to Windows 7 and Adobe Reader versions later than 8.1.3 did not work.  Was told by Adobe there was no reader compatible yet with 7.  So, have been using 8.1.3 without any problem UNTIL the other day when I upgraded Intern