How to do extraction in fi module?

how to do extraction in fi module?

Hi,
Everything related to FI Extraction.....
https://www.sdn.sap.com/irj/sdn/advancedsearch?query=fi%20extraction&cat=sdn_all
Cheers!
Amit

Similar Messages

  • How to do data source ehancement by using "Extraction by function module"

    I have one customized datasource "ZSOURCE" in R/3, this datasource use Extraction by function module, namely one functiona
    module "ZBI_FM_EX"and Extract. struct "ZBI_EX".
    Now I want to add one field "ZNEW" from standard SAP table LIKP into extractor "ZBI_EX" and write coding in ZXRSAU01.
    Question, could I add new field "ZNEW" into Structure:"ZBI_EX"? Do I need to change anything in functional module "ZBI_FM_EX" itself?
    Many Thanks!
    rajatina.

    Hi Dear,
                  It is good to write the code in your function module i.e. ZBI_FM_EX. becuase writing the code in ZXRSAU01 include program will affect the loading performance. instead of looping the data two time (one in your FM and again in ZXRSAU01 ), you can get the same will only loop.
    Thanks
    Obaid
    Edited by: obaid shaikh on Jan 21, 2011 11:53 AM

  • Generic extraction using function module and view

    hi every one ,
    iam new to bw and can anyone plz tell me how to extract the data from R/3 to bw using generic extractor by creating function module and a view
    thank u,
    kishore

    Hi Kishore,
    Check this blog:
    /people/siegfried.szameitat/blog/2005/09/29/generic-extraction-via-function-module
    Also Check this doc:
    http://help.sap.com/saphelp_nw04/helpdata/en/3f/548c9ec754ee4d90188a4f108e0121/frameset.htm
    Generic Extractors
    Generic data sources
    Generic DS
    Bye
    Dinesh

  • Creating BW Function module to extract R3 Function module data.

    Could you tell me how to create a BW Function Module to Extract data from  R/3 Function module?.
    Also, the BW function module needs to pass a date/time filter to R/3 function module basis which the R/3 function module passes the date/time restricted data to BW function module.
    Thanks,
    Gautam

    You will have to create a function module in R/3 and then call the same in BW using the RFC call function option.
    Please do not raise separate threads for each question - you have asked the same question in another post of yours..
    bw extraction using function module
    http://tinyurl.com/lwhtk8
    this will give you an idea on how you can achieve this.

  • Generic Delta extraction by Function module issue

    Hello Experts,
    Please help !!!
    I have problem for delta extraction by Function module.  For the full load, I wrote function module based on RSAX_BIW_GET_DATA_SIMPLE. It works fine.
    But I would like to have the delta load enabled. Therefore, I modified the datasource, add a delta specific field u2018ztimestampu2019, which type is calendar day.
    Then I create a function module based on template u2018RSAX_BIW_GET_DATAu2019, as this support the upload mode. But when I test this datasource in RSA3, no matter itu2019s full load or initial delta load, it always send me an error, u201CErrors occurred during the extractionu201D.
    I had some debug, and found that there is no value  for i_isource when my function module is called. Therefore it raised the exception.
    But I do not have the chance to debug my code for the delta logic, can somebody help to check?
    I also check the entries in ROOSOURCE,
    For my datasource ZTRNREC_FM_DELTA, The DELTA value is u2018AIEu2019, and extraction method is u2018F2u2019, should I change them to DELTA= u2018Du2019 and extraction method to u2018F1u2019? Where to change?
    FUNCTION ZRSAX_TRAININGREC_DELTA.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(I_REQUNR) TYPE  SBIWA_S_INTERFACE-REQUNR
    *"     VALUE(I_ISOURCE) TYPE  SBIWA_S_INTERFACE-ISOURCE OPTIONAL
    *"     VALUE(I_MAXSIZE) TYPE  SBIWA_S_INTERFACE-MAXSIZE OPTIONAL
    *"     VALUE(I_INITFLAG) TYPE  SBIWA_S_INTERFACE-INITFLAG OPTIONAL
    *"     VALUE(I_UPDMODE) TYPE  SBIWA_S_INTERFACE-UPDMODE OPTIONAL
    *"     VALUE(I_DATAPAKID) TYPE  SBIWA_S_INTERFACE-DATAPAKID OPTIONAL
    *"     VALUE(I_PRIVATE_MODE) OPTIONAL
    *"     VALUE(I_CALLMODE) LIKE  ROARCHD200-CALLMODE OPTIONAL
    *"     VALUE(I_REMOTE_CALL) TYPE  SBIWA_FLAG DEFAULT SBIWA_C_FLAG_OFF
    *"  TABLES
    *"      I_T_SELECT TYPE  SBIWA_T_SELECT OPTIONAL
    *"      I_T_FIELDS TYPE  SBIWA_T_FIELDS OPTIONAL
    *"      E_T_DATA STRUCTURE  ZTRN_REC_TIME OPTIONAL
    *"      E_T_SOURCE_STRUCTURE_NAME OPTIONAL
    *"  EXCEPTIONS
    *"      NO_MORE_DATA
    *"      ERROR_PASSED_TO_MESS_HANDLER
    The input parameter I_DATAPAKID is not supported yet !
    Example: InfoSource containing TADIR objects
    Auxiliary Selection criteria structure
      DATA: l_s_select TYPE sbiwa_s_select.
    Maximum number of lines for DB table
      STATICS: l_maxsize TYPE sbiwa_s_interface-maxsize,
              S_S_IF TYPE SRSC_S_IF_SIMPLE,
              S_COUNTER_DATAPAKID LIKE SY-TABIX.
    Parameter I_PRIVATE_MODE:
    Some applications might want to use this function module for other
    purposes as well (e.g. data supply for OLTP reporting tools). If the
    processing logic has to be different in this case, use the optional
    parameter I_PRIVATE_MODE (not supplied by BIW !) to distinguish
    between BIW calls (I_PRIVATE_MODE = SPACE) and other calls
    (I_PRIVATE_MODE = X).
    If the message handling has to be different as well, define Your own
    messaging macro which interprets parameter I_PRIVATE_MODE. When
    called by BIW, it should use the LOG_WRITE macro, otherwise do what
    You want.
    Initialization mode (first call by SAPI) or data transfer mode
    (following calls) ?
      IF i_initflag = sbiwa_c_flag_on.
    Initialization: check input parameters
                    buffer input parameters
                    prepare data selection
    The input parameter I_DATAPAKID is not supported yet !
    Invalid second initialization call -> error exit
        IF NOT g_flag_interface_initialized IS INITIAL.
          IF 1 = 2. MESSAGE e008(r3). ENDIF.
          log_write 'E'                    "message type
                    'R3'                   "message class
                    '008'                  "message number
                    ' '                    "message variable 1
                    ' '.                   "message variable 2
          RAISE error_passed_to_mess_handler.
        ENDIF.
    Check InfoSource validity
        CASE i_isource.
          WHEN 'ZTRNREC_FM_DELTA'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE e009(r3). ENDIF.
            log_write 'E'                  "message type
                      'R3'                 "message class
                      '009'                "message number
                      i_isource            "message variable 1
                      ' '.                 "message variable 2
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    Check for supported update mode
        CASE i_updmode.
          WHEN 'F'.
          WHEN 'D'.
          WHEN 'R'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE e011(r3). ENDIF.
            log_write 'E'                  "message type
                      'R3'                 "message class
                      '011'                "message number
                      i_updmode            "message variable 1
                      ' '.                 "message variable 2
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    Check for obligatory selection criteria
        APPEND LINES OF i_t_select TO g_t_select.
    Fill parameter buffer for data extraction calls
        g_s_interface-requnr    = i_requnr.
        g_s_interface-isource   = i_isource.
        g_s_interface-maxsize   = i_maxsize.
        g_s_interface-initflag  = i_initflag.
        g_s_interface-updmode   = i_updmode.
        g_s_interface-datapakid = i_datapakid.
        g_flag_interface_initialized = sbiwa_c_flag_on.
    Fill field list table for an optimized select statement
    (in case that there is no 1:1 relation between InfoSource fields
    and database table fields this may be far from beeing trivial)
        APPEND LINES OF i_t_fields TO g_t_segfields.
      ELSE.                 "Initialization mode or data extraction ?
    Data transfer: First Call      OPEN CURSOR + FETCH
                   Following Calls FETCH only
      LOOP AT G_T_SELECT INTO L_S_SELECT
            WHERE FIELDNM = 'ZTIMESTAMP'.
      ENDLOOP.
          IF G_COUNTER_DATAPAKID = 0.
            IF L_S_SELECT-LOW = '' AND L_S_SELECT-HIGH = ''.
            OPEN CURSOR WITH HOLD G_CURSOR FOR
                SELECT (g_t_fields)
                FROM ZTRN_REC_TIME.
            ELSE.
              OPEN CURSOR WITH HOLD G_CURSOR FOR
                SELECT (g_t_fields)
                FROM ZTRN_REC_TIME
                WHERE ZTIMESTAMP >= L_S_SELECT-LOW
                  AND ZTIMESTAMP  <= L_S_SELECT-HIGH.
            ENDIF.
          ENDIF.
      FETCH NEXT CURSOR G_CURSOR
                   APPENDING CORRESPONDING FIELDS
                   OF TABLE E_T_DATA
                   PACKAGE SIZE S_S_IF-MAXSIZE.
        IF SY-SUBRC <> 0.
          CLOSE CURSOR G_CURSOR.
          RAISE NO_MORE_DATA.
        ENDIF.
        S_COUNTER_DATAPAKID = S_COUNTER_DATAPAKID + 1.
      ENDIF.
    ENDFUNCTION.
    I found some similar issue in this forum by link
    Generic Extractor Delta Function Module code, but still I could not get clear answer.
    Can you please help me:
    1)     why there is no value for i_source , how to fix it?
    2)     For the delta logic for ztimestemp, is it correct?
    3)     Need I modify the entries in ROOSOURCE ?
    Thanks a lot !!!

    Hello Andre,
            Thanks a lot for your help. I did some change , but still does not work. Could you please help check.
    Now the source code are the following, It's based on the RSAX_BIW_GET_DATA_SIMPLE, as you confirm that this also supply the update mode (full, initial delta, delta).
    FUNCTION RSAX_BIW_GET_DATA_TRAININGREC1.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(I_REQUNR) TYPE  SRSC_S_IF_SIMPLE-REQUNR
    *"     VALUE(I_DSOURCE) TYPE  SRSC_S_IF_SIMPLE-DSOURCE OPTIONAL
    *"     VALUE(I_MAXSIZE) TYPE  SRSC_S_IF_SIMPLE-MAXSIZE OPTIONAL
    *"     VALUE(I_INITFLAG) TYPE  SRSC_S_IF_SIMPLE-INITFLAG OPTIONAL
    *"     VALUE(I_READ_ONLY) TYPE  SRSC_S_IF_SIMPLE-READONLY OPTIONAL
    *"     VALUE(I_REMOTE_CALL) TYPE  SBIWA_FLAG DEFAULT SBIWA_C_FLAG_OFF
    *"  TABLES
    *"      I_T_SELECT TYPE  SRSC_S_IF_SIMPLE-T_SELECT OPTIONAL
    *"      I_T_FIELDS TYPE  SRSC_S_IF_SIMPLE-T_FIELDS OPTIONAL
    *"      E_T_DATA STRUCTURE  ZTRN_REC_TIME OPTIONAL
    *"  EXCEPTIONS
    *"      NO_MORE_DATA
    *"      ERROR_PASSED_TO_MESS_HANDLER
    Auxiliary Selection criteria structure
      DATA: L_S_SELECT TYPE SRSC_S_SELECT.
    Maximum number of lines for DB table
      STATICS: S_S_IF TYPE SRSC_S_IF_SIMPLE,
    counter
              S_COUNTER_DATAPAKID LIKE SY-TABIX,
    cursor
              S_CURSOR TYPE CURSOR.
    Select ranges
    RANGES:
            L_R_ZTIMESTAMP FOR ZTRN_REC_TIME-ZTIMESTAMP.
    Initialization mode (first call by SAPI) or data transfer mode
    (following calls) ?
      IF I_INITFLAG = SBIWA_C_FLAG_ON.
    Initialization: check input parameters
                    buffer input parameters
                    prepare data selection
    Check DataSource validity
        CASE I_DSOURCE.
          WHEN 'ZTRNREC_FM'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE E009(R3). ENDIF.
    this is a typical log call. Please write every error message like this
            LOG_WRITE 'E'                  "message type
                      'R3'                 "message class
                      '009'                "message number
                      I_DSOURCE   "message variable 1
                      ' '.                 "message variable 2
            RAISE ERROR_PASSED_TO_MESS_HANDLER.
        ENDCASE.
        APPEND LINES OF I_T_SELECT TO S_S_IF-T_SELECT.
    Fill parameter buffer for data extraction calls
        S_S_IF-REQUNR    = I_REQUNR.
        S_S_IF-DSOURCE = I_DSOURCE.
        S_S_IF-MAXSIZE   = I_MAXSIZE.
    Fill field list table for an optimized select statement
    (in case that there is no 1:1 relation between InfoSource fields
    and database table fields this may be far from beeing trivial)
        APPEND LINES OF I_T_FIELDS TO S_S_IF-T_FIELDS.
      ELSE.                 "Initialization mode or data extraction ?
    Data transfer: First Call      OPEN CURSOR + FETCH
                   Following Calls FETCH only
    First data package -> OPEN CURSOR
        IF S_COUNTER_DATAPAKID = 0.
          LOOP AT S_S_IF-T_SELECT INTO L_S_SELECT WHERE FIELDNM = 'ZTIMESTAMP'.
          MOVE-CORRESPONDING L_S_SELECT TO L_R_ZTIMESTAMP.
          APPEND L_R_ZTIMESTAMP.
          ENDLOOP.
    Determine number of database records to be read per FETCH statement
    from input parameter I_MAXSIZE. If there is a one to one relation
    between DataSource table lines and database entries, this is trivial.
    In other cases, it may be impossible and some estimated value has to
    be determined.
         IF L_S_SELECT-LOW = '' AND L_S_SELECT-HIGH = ''.
            OPEN CURSOR WITH HOLD S_CURSOR FOR
            SELECT (S_S_IF-T_FIELDS)
            FROM ZTRN_REC_TIME.
            ELSE.
            OPEN CURSOR WITH HOLD G_CURSOR FOR
            SELECT (S_S_IF-T_FIELDS)
            FROM ZTRN_REC_TIME
            WHERE ZTIMESTAMP >= L_S_SELECT-LOW
            AND ZTIMESTAMP <= L_S_SELECT-HIGH.
         ENDIF.
        ENDIF.                             "First data package ?
    Fetch records into interface table.
      named E_T_'Name of extract structure'.
        FETCH NEXT CURSOR S_CURSOR
                   APPENDING CORRESPONDING FIELDS
                   OF TABLE E_T_DATA
                   PACKAGE SIZE S_S_IF-MAXSIZE.
        IF SY-SUBRC <> 0.
          CLOSE CURSOR S_CURSOR.
          RAISE NO_MORE_DATA.
        ENDIF.
        S_COUNTER_DATAPAKID = S_COUNTER_DATAPAKID + 1.
      ENDIF.              "Initialization mode or data extraction ?
    ENDFUNCTION.
    I think it already includes the important statements you suggested.
    I test this FM in RSA3, for the Full load mode, it works fine. Also if I checked the debug mode in execution , it will stop in the code and let me debug.
    But when I choose other mode, like 'initializion of the delta transfer'  or simulation of initial delta, I always get error 'error occurs  during the extraction' .. even I choose debug mode, but it could not enter the code for debug..
    Till now I did not see any parameter or value for the upload mode..
    Another questions is that, in RSO2, I define Ztimestamp as my delta field.. But , can I add other field as selection condition in the datasource definition, and has its range table in this function module ?
    Should I change the entries in ROOSOURCE for this datasource ??
    Please let me know your feedback, do you have some concret example for generic delta extraction ?
    Thanks a lot !

  • RE: how to add attributes in graphical modulator in segment builder .

    Hi Gurus,
    can you please help me how to add attributes in graphical modulator in segment builder in sap CRM 7.0 WEB-UI.
    thanks and regards
    satyanarayana
    Edited by: koradasatya on Oct 27, 2011 8:14 PM

    Hi Gurus,
    thanks for your reply my requirement from client is given below if you could answer this it will be a great help for me.
    WKSC needs to be able to make selections (in segment builder) with the possibilities to use stored data on organizations. The information we are missing in Segment builder (SB) (and Account search for industrycode) are Industrycode (we want to see values not codes) and responsible salesrep (values not codes).
    These variables together with regions and other marketing attributes is crucial for us. Without it we cannot use the functionality built.
    We also need it so that we can extract smaller parts of our customers and prospects and update them with information from the thirdparty or adding new persons to them.
    Everyone using the SB should be able to use the fields for selections. i.e. Marketers, marketing managers and power users.
    Example
    We would like to make selections that could look like this.
    Region: A and B
    Organization in Industrycode C
    Sales rep: D, E, and F
    Turnover: above 50000
    CP on selected orgs
    CP has title G or H
    CP has Email not blank
    thanks and regards
    satya

  • How can I use the print module to print different size images on one large "canvas"?

    How can I use the print module to print different size images on one large "canvas"? An example would be in Photoshop, go to file>new, and create the size paper I want, and move images of different sizes onto it.
    I was thinking the print module would do this automatically for me.

    You can't, at present. It's been a requested feature, so we'll see if it shows up in a future version, but it's not there at present.

  • How to create a callback function module

    Hi all,
    I am working in a requirement where we need to call a function module at a 'after change' event. So how to create a callback function module and register it with the crmvevent ?_
    I created a sample function module and try to create entries in table crmv_event_cust, but i got an error message saying that the function module name I provided is not in table CRMC_FUNC_ASSIGN. When I try to create entry there, I got a message that function module is not in CRMC_OBJ_FUNC and that table is a standard table with no maintanance options !!
    looks like i am going in wrong way ... can any one please help ??

    Looking at my system all you need to do is create the entry for the callback function in maint view: CRMV_FUNC_ASSIGN.
    Your entry should be as simple as Z-function name Object Function - <same as others in the segment you are assigning>
    IE for the partner it would be CRM_PARTNER as object function, for general order processing CRM_ORDER
    Take care,
    Stephen

  • How to check for a function module with its description and functionality

    Hi all,
    How to check for a function module,with its description and its functionality,in detail how can I know the purpose of a particular function module,how to search for a function module which suits my requirement .

    Hi,
    You can search a FM of your requirement by putting in the Key words and searching for a FM. Like * KEYWORD * and then pressing F4.
    Say for example you need to search something regarding converstion.
    Search for * CONVERT * and press F4.
    If there is something specfic like converting date to something you can give
    DATE * CONVERT *
    OR
    CONVERT * DATE *  and press F4.
    Once you narrow down your search you will have a Function module documentation inside the Function module. Please note that all the FMs willl not have documentation.
    Regards,
    Pramod

  • How to go into a function module through SE80 t - code

    Hi All , 
                 How to go into a function module through SE80 t - code.
    Thanks in advance.

    >
    Balaji Krishnamoorthy wrote:
    > Hi All , 
    >              How to go into a function module through SE80 t - code.
    >
    > Thanks in advance.
    Hi,
    With  help of  function group
    Thanks & Regards
    Edited by: Always Learner on Oct 16, 2008 2:31 PM

  • How to config Check Digits function module for Student Number Validation

    Hi SLCM Experts,
    In the SAP-SLCM, How to use check digits function module for validate student number.  Just only config it or need to customizing program.
    *Any idea to student number validation in SLCM?*
    Best Regards,
    Suvatchai K.

    Hi ,
    Can you expalin it further ?
    You configure the St. no in piq_matr . And set it  as external or internal no. range which suits your business .
    What is the validation you are looking for ?
    Regards
    Gajalakshmi

  • How to connect our outbound function module to the message type

    how to connect our outbound function module to the message type any transcation code exits to assign the message type with the function module .
    Thank in advance .
    A. Thiru

    Hi Thiru,
    Standard Transaction Codes, have their own Function Modules for generating Outbound/Indbound Idocs. Where these Function Modules will be configured to a particular Process Codes.
    For E.g for PO's
    Process code : ME10 - IDOC_OUTPUT_ORDERS - for creation
    In case if its a Z Function Module, It depends on the case how you use IDOC types. either directly through Z Program or through Inbound/Outbound Process  codes with respective Function modules.
    Regards,
    Anbalagan

  • How to create a custom function module with the records in SAP R/3?

    Hi All,
    How to create a custom function module with the records in SAP R/3? Using RFC Adapter I have to fetch the custom function module records.
    Regards
    Sara

    Hi
    goto se37...here u need to create a function group... then u need to create a function module. inside assign import/export parameters. assign tables/exceptions. activate the same. now write ur code within the function module
    http://help.sap.com/saphelp_nw04/helpdata/en/9f/db98fc35c111d1829f0000e829fbfe/content.htm
    Look at the below SAP HELP links, These links will show you the way to create a Function Module
    http://help.sap.com/saphelp_nw04/helpdata/en/26/64f623fa8911d386e70000e82011b8/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/9f/db98fc35c111d1829f0000e829fbfe/content.htm

  • How to code a predifined function module in sap ,in se37.

    can any one tell me how to code a predifined function module in sap ,in se37.it's an immediate requirement.if u give a brief description it'll do.

    Hi Henry,
    There are two possible ways in which I can interpret your question.
    1. You want to create a new Function Module in SE37. you will have to refer to the <a href="http://help.sap.com/saphelp_47x200/helpdata/en/d1/801e9a454211d189710000e8322d00/frameset.htm">Function Builder</a> tutorial for that.
    2. You want to use an existing function module in your program. In the code of your program in SE38, click the button <i>Pattern</i>. On the pop-up, give the name of the function module that you wish to use in your program.
    Regards,
    Anand Mandalika.

  • How to replace obsolete download function module in ECC6.0?

    Hi Experts,
    How to replace obsolete download function module in ECC6.0?
    Thanks,
    Adi.

    Hi,
    DOWNLOAD is obsolete FM in ECC 6. To get the same functionality , we need to use
    CL_GUI_FRONTEND_SERVICES=>FILE_SAVE_DIALOG  method (It provides the File selection feature)
    and
    GUI_DOWNLOAD function module.(It downloads the internal table from program to presentation server)
    Please see the example below:
    Example:
    *CALL FUNCTION 'DOWNLOAD'
              EXPORTING
                   FILENAME            = p_filename
                   FILETYPE            = ‘DAT’
              TABLES
                   DATA_TAB            = T_DOWNL
              EXCEPTIONS
                   INVALID_FILESIZE    = 1
                   INVALID_TABLE_WIDTH = 2
                   INVALID_TYPE        = 3
                   NO_BATCH            = 4
                   UNKNOWN_ERROR       = 5
                   OTHERS              = 6.
    *End of deletion CH01-
    Replacement Method for above code:
    DATA: l_filename    TYPE string,
           l_filen       TYPE string,
           l_path        TYPE string,
           l_fullpath    TYPE string,
           l_usr_act     TYPE I.
    l_filename = P_filename.
    CALL METHOD CL_GUI_FRONTEND_SERVICES=>FILE_SAVE_DIALOG
      EXPORTING
        DEFAULT_FILE_NAME    = l_filename
      CHANGING
        FILENAME             = l_filen
        PATH                 = l_path
        FULLPATH             = l_fullpath
        USER_ACTION          = l_usr_act
      EXCEPTIONS
        CNTL_ERROR           = 1
        ERROR_NO_GUI         = 2
        NOT_SUPPORTED_BY_GUI = 3
        others               = 4.
    IF sy-subrc = 0
          AND l_usr_act <>
          CL_GUI_FRONTEND_SERVICES=>ACTION_CANCEL.
    CALL FUNCTION 'GUI_DOWNLOAD'
      EXPORTING
        FILENAME                        = l_fullpath
       FILETYPE                        = 'DAT'
      TABLES
        DATA_TAB                        = T_DOWNL
    EXCEPTIONS
       FILE_WRITE_ERROR                = 1
       NO_BATCH                        = 2
       GUI_REFUSE_FILETRANSFER         = 3
       INVALID_TYPE                    = 4
       NO_AUTHORITY                    = 5
       UNKNOWN_ERROR                   = 6
       HEADER_NOT_ALLOWED              = 7
       SEPARATOR_NOT_ALLOWED           = 8
       FILESIZE_NOT_ALLOWED            = 9
       HEADER_TOO_LONG                 = 10
       DP_ERROR_CREATE                 = 11
       DP_ERROR_SEND                   = 12
       DP_ERROR_WRITE                  = 13
       UNKNOWN_DP_ERROR                = 14
       ACCESS_DENIED                   = 15
       DP_OUT_OF_MEMORY                = 16
       DISK_FULL                       = 17
       DP_TIMEOUT                      = 18
       FILE_NOT_FOUND                  = 19
       DATAPROVIDER_EXCEPTION          = 20
       CONTROL_FLUSH_ERROR             = 21
       OTHERS                          = 22.

Maybe you are looking for

  • I am trying to run PASW with Lion.

    I am trying to run PASW with Lion.  I've found a patch that allows it to run, except that it will not do graphs. These always produce this warning: 'Could Not Start Java Virtual Machine. Chart will not be drawn."  Anyone know of another patch for thi

  • C   RUNTIME ERROR

    my issue is  1.i am getting the attached error when i try to submit my tender thr' web site name "www.ireps.gov.in" . 2. basic need to log in & to submit the tender thr' this site is ie6,7,8 or 9 & windows xp/sp3, vista or 7  & DIGITAL SIGNATURE CERT

  • On start up sometimes I get a blue screen and start up hang there

    On start up I sometimes get a blue screen and it hangs there the only way to get out of this is to turn the iMac off at the back then when you turn it back on the desk top appears without going through the startup screens. Even had the blue screen wh

  • [SOLVED]epiphany 3.12.0 - plugins?

    Hello, As you may know, extensions.gnome.org is offering an "automatic" way to install extensions of gnome-shell, but when trying to use it on Arch/epiphany 3.12.0, I get this: We cannot detect a running copy of GNOME on this system, so some parts of

  • VL32N screen - new field