How to enhance OM infotypes
Hi experts can any one tell me how to enhance OM Infotypes. I mean to say what is the Tcode? i think it PPCI is it correct ? and what is the procedure to enhance the OM infotype? if possible explain with an example.
Thanks in advance.
vamsi.
Hi,
Tcode PPCM is used to create OM infotypes.
Give the infotype no. & create the CI include first & then All button.
Hope this helps.
Thanks,
Sarika.
Similar Messages
-
How to enhance Timpe Infotype?
Hi,
I want to add a field to IT2001. Hot do I do that. AM sure that this cannot be done through PM01. Can some one let me know whether it is possible at all, if yes how to go ahead
regardsHi,
Suresh is right, there is no provision to enhance IT2001. You may wish to check SAP Note 412261 to confirm this, and a workaround via customer specific infotype. Thanks.
Regards
Kir Chern -
Enhance Standard Infotype 1005 in HR
Dear All,
Please suggest how to enhance standard infotype 1005 - Planned Compensation in HR.Transcation PM01 is not allowing to do so ...as no CI include is attached for the same.
Please guide.
Regards,
Subhashhi,
maybe you can achieve your requirement by creating a new custom OM infotype
( if the custom information are linked to the OM entity : org unit, positions.. ) or a new PA infotype ( if the custom information are linked to the employee ) .
Regards luigi
Edited by: luigi la motta on Sep 2, 2011 11:46 AM -
How to Enhance the info type in ECC 6.0,
I face a problem while enhanceing the infotype in EEC 6.0 ,
but i know how to enhance in 4.7, here i face a problem is
a error message comming like this
"" SCREEN STRUCTURES AND CONVERSION CLASSES ARE NOT CREATED IN CORE SYSTEM"""
what is that mean.
actually i follow procedure in EEC 6.0 is
initally go to T-CODE PM01 , then enter the info type num and click on edit button ,it will navigate into create the strrecture ,then iam creating the domain ,data element and save active.
then i click on GENERATE OBJECT button.
finalliy i face above message like that,
plz give me an idia ..
Thank& Regards
varmaPlease follow follwoing steps for PA infotypes.
1. Execute PM01.
2. Select 4th Tab as "SingleScrn" and enter infotype no. (eg. 0001).
3. click Generate Objects button.
4. Will get a screen for entering fields which u want to append to infotypes.
5. Activate it.
Pls mark necessary points if this helps to u.
Regards,
Ranjith -
Hi
I want to enhance infotype 1050 with a note. Could anyone explain (just in short) how i could do that? I can imagine how to enhance with a single entry field - but in this case i want a note (like in 1002 or something like that).
Is there an easy way to do this?
JakobHi Jakob,
1002 infotype is a table infotype which stores tabnr against every entry in 1002.
the actual text is stored in hrt1002 where the tabnr is the key field and the seqnr is each line entered of 79 characters.
I suggest not to follow the same approach in 1050, instead enhance the infotype to include a field which stores a unique no. generated by some custom number range. Then create a text id and element and store the text against it in the z program generated for the enhanced infotype using function modules read_text, save_text.
If you still do not want to do this the best approach would be to add a subtype in 1002 infotype where the job evaluation results are stored, this will require no development.
Regards,
Divya -
Hi experts can any one guide me how to create OM Infotype?
I know that we need to create a structure using SE11. then we need to go with the creation of Infotype.Dear Vamsi
Check this out
How to create a HR infotype?
1) Go to Transaction PM01.
2) Enter the custom Infotype number which you want to create (Should be a 4 digit number, start with 9).
3) Select the Employee Infotype radio button.
4) Select the PS Structure Infotype.
5) Click on Create A separate table maintenance window appears
6) Create a PS structure with all the fields you want on the Infotype
7) Save and Activate the PS structure
8) Go back to the initial screen of PM01.
9) Click on All push button. It takes a few moments.
10) Click on Technical Characteristics. Infotype list screen appears
11) Click on Change(pencil) button
12) Select your Infotype and click on Detail (magnifying glass) button
13) Give T591A as subtype table
14) Give T591S as subtype txt tab
15) Give your subtype field as subtype field
16) Save and come back to PM01 initial screen
17) Click on Infotype Characteristics Infotype list screen appears
18) Click on Change (pencil) button
19) Click on New Entries
20) Enter your Infotype number and short text
21) Here we have to set different Infotype Characteristics as per the requirement. (Better open another session with some standard Infotypes infotype characteristics screen and use as the reference to fill yours)
22) Save your entries.
23) Now the Infotype is created and ready to use.
24) If you want to change the layout of the Infotype as per your requirement
25) In the PM01 initial screen Select Screen radio button and give 2000 as the screen name, then click on edit.
26) In the next screen.. Select Layout Editor and click Change.
27) Screen default layout appears here you can design/modify the screen..change the attributes of the fields..etc.
28) Save and activate. (Dont forget to Activate at every level)
Another way of creating the infotype with screen shots:
Creating a New Infotype
Step 1
Execute transaction PM01 (If you get a message saying the infotype can not be enhanced,
try transaction PPCI).
Step 2
Select create IT tab and enter new infotype number into selection box.
Step 3
Press the create ALL button (left of infotype no.). You will get a dialog box asking to confirm,
press the create button.
Step 4
You will now be presented with the standard structure creation screen (SE11) where you need to
enter the fields of the new infotype. I have entered some examples but you can put anything in
here.
Step 5
Once you have entered the fields press save and then activate, before pressing the back button.
You will now be presented with the following screen, where you will need to make a new entry
or your created infotype (i.e. 9010).
Step 6
The next step is to fill in the infotype attributes, these will initially be blank and you will need to
fill them in similar to the following, depending on your requirements. Then press save.
Step 7
Your infotype is now created and can be accessed and populated in the usual way using
i.e. using transactions such as PA20 and PA30.
Step 8
If you look at the structure of your new infotype in transaction SE11 it will look similar to the
following:
Award points if helpful
regards
jayeeta -
How to enhance IT 1001 additional data screen.
Hi Folks,
I want to enhance IT1001 additional data screen, (I want to add two fields on the screen), the table of it is HRPAD34 and it also contains CI include, But When i try to enhance it through PPCI T-code, I'm unable to do it, Can any buddy suggest how to enhance screen of additional data of IT1001.
Thanks
Teja.try this link u will get enhancing infotype....
<link to blocked site removed by moderator>
Thanks,
Amol
Edited by: Thomas Zloch on Feb 6, 2012 -
Hi all,
How to enhance the Table Infotype in PD (as I know to enhance Field Infotype through PPCM) and may I know is it possible to enhance Table Infotype. If possible, pls help in this regard.
Regards,
V KumarHi nachiappan mv,
Thanks for the reply and there is no information in the material of how to enhance the standard table Infotype and tried with PPCI and it seems there is no CI Include for Table Infotype and may I know how can I enhance the standard Table Infotype. Pls help in this regard.
@ pratyush v
I tried in PPCI but there is no CI Include for Table Infotype and may I know how can I enhance the standard Table Infotype. Pls help in this regard.
Regards,
V Kumar -
i upload iPhone pics to Shutterfly, which gives me a "low resolution" warning and blurry prints. Does anyone know how to enhance resolution/printing quality of iPhone pictures?
iPhone 5How does iPhoto play a part in this? You're in the iPhoto forum. Shouldn't you be asking your question in the iPhone forum? I'll ask the powers to be to move you question to the iPhone forum.
OT -
How to create custom infotype for training and event management
hai freinds can any one tell me how to create custom infotype for training and event managment with following fields
PS No PA0000-> PERNR
Name - PA0001 -> ENAME
IS PS.No. PA0001-> PS no. of Immediate Superior
IS name PA0001 -> ENAME
thanx in advance
afzalHi,
Your question is not clear for me. Since it is a TEM infotype, it could be a PD infotype.
If you wish to create a PD infotype, use transaction PPCI to create the infotype.
But before that you need to create a structure HRInnnn (where nnnn is the infotype number) with all the fields relevant for the infotype.
If you wish to create a PA infotype, use transaction PM01 to create the infotype.
But before that you may be required to create a strcuture PSnnnn (where nnnn is the infotype number) with all the fields relevant for the infotype.
Regards,
Srini -
How to enhance table control in DMS. Need to display doknr more than 25 cha
Hi there.
In transaction IL03 - document tab - I need to display a doknr which is longer than 25 characters.
I search for exit/enhancement for DMS - saplcv140/control SUB_DOC, but cant find anything.
If it is not possible to enhance this field, i would like to add a new field (more than 25 char) and fill in the long doknr.
The documents that are attached contains both an internal docnumber(from the external system) and an external docnumber (functional location type of number). It is very important to show external documentno in the table control.
Actually in the table DRAW the external dok number is in the field MRK_FILEP. Can this field somehow get in the tablecontrol?
Anybody has experience with docno longer than 25 characters? Or how to enhance tablecontrol sub_doc (screen 0204) in fuction group CV140.
Br,
Liselotte.The BAdI CRM_BADI_RF_Q1O_SEARCH is for enhancing OneOrder based searches. Not for business partners.
The BAdI CRM_BUPA_IL_SEARCH is the way to go. I just checked in our system.
In the method SEARCH_CRITERIA_INITIAL check if your field is supplied in IS_PARAMETERS. If yes return CV_IS_NOT_INITIAL = 'X'.
Then in SEARCH_PARTNERS you delete the entries from table CT_PARTNER_KEYS according to your parameter.
However this is not very performant. If you have a search with criteria only of your own for the BAdI SAP coding will first select everything and then you filter out.
Anyway, it is much faster to implement than a new search...
cheers Carsten
Edited by: Carsten Kasper on Nov 18, 2008 7:44 PM -
How to create an infotype in sap ecc6.0 ?
Hi all,
I know i how to create an infotype in sap 4.7, but i am facing the problem while
creating an infotype in sap ecc6.0 version. could u plz provide me the info with screen shots how to create an infotype and how to enhace that infotype ?
Waiting for u r response.
Regards,
RaviHi ,
To create OM infotype:
1. Go to SE11 and create a structure HRI9XXX (9XXX --> name of the infotype). Add the required fields to this structure and save and activate. then come out of it.
2. Go to PPCI and enter Infotype number (9XXX) and description.
3. Click create.
4. In the infotype category select details for the infotype.
5. Click create button. It should create the infotype.
6. Click on Check. A window with menu will open.
7. In that window navigate to Table Entries.
8. Under table Entries, select T777I and click on change.
9. It opens SM30. Click on Maintain.
10. Select the infotype and add information for "Time Constraint" and "Infotype Per Object Type".
11. Save.
12. Go back to check menu, see if all entries exist. Do not worry last 5 table entries. And you are done -
How to add an Infotype to an exsting Infoset (ad hoc query)
Hi,
How to add an Infotype (Ex. 0025) to an exsting Infoset (ad hoc query)?
I was trying by clicking on 'Extras' tab & create...I get three options, create field, create table or create structure.
I am not sure which to use or is there any other way? Pls. let me know the steps...
Also what is this 'Package', which is aked whenever you create or change an Infoset.
Pls. suggest.
Tnx
SKRI was able to add the infotype by adding the table as PA0025 & include all the fields in the field group.
When I check, I get the following error:
"Access to PA0025 with sequence no. 01"
Message Text
Access to PA0025 with sequence number 01
Technical data
Message type__________ W (Warning)
Message class_________ AQ (Message texts for SAP Query)
Message number________ 006
Message variable 1____ Access to PA0025 with sequence number 01
Message variable 2____
Message variable 3____
Message variable 4____
Message attributes
Level of detail_______ 4 (Level of detail 4)
Problem class_________ 3 (medium)
Sort criterion________
Number________________ 1
Do we need to input the sequence no. as 00? or is their anything else that I have to maintain?
Tnx
SKR -
How to push custom infotype details to Standard Log Report
Hi Experts,
i am using S_AHR_61016380 SAP Standard Report for Log Change Data in
the report development. However, the standard report for logged changes
does not capture the long term documents run for the custom infotype.
it is only giving the logged changes for the standard SAP infotypes
and it doesnot capture any details for the custom infotype.
We are looking a possibility on how to push custom infotype details to S_AHR_61016380.
Pls suggest in case you have any inputs for the same.
Thanks & Regards,
Kishore.Hello Amith,
As u said i have created a Z program, and also i have used the following FMs.
1. 'HR_INFOTYPE_LOG_GET_LIST'
2. 'HR_INFOTYPE_LOG_GET_DETAIL'
Using these FMs i am able to get log records from the standard infotypes but i am unable to fetch data from the custom infotype tables.
Please give me any solution to read the log records from the custom infotype tables.
Thanks,
Kishore -
How to Enhance the Standard Report?
Hi All,
How to Enhance the Standard Report? :
When I am trying to execute the query called ZTIMES in the user group SQ01 it is navigating the screen to selection-screen with some inputs to be given here on the selection screen company code is mandatory as an input. The company code field is having the search help and it is fetching the values for the company code from table called PROJ Table (Project definition Table).But I want the company code should fetch the value from the PRPS Table ( Work break structure(WBS Element) Level).
Tables used are PROJ and PRPS.
The company code in PROJ is PROJ-VBUKR
In PRPS is PRPS-PBUKR
In the coding part related to that selection screen I have to replace PROJ-VBUKR with
PRPS-PBUKR.But it is standard report to enhance.
What is suggestible solution for this issue?
Thanks,
M RajuHi,
Since this is an ABAP Query, You can change the infoset query in SQ02 and establish the join linkages between PROJ and PRPS
Also on the selection screen of the Query make sure you provide company code from PRPS table and report output also from the same table reference.
Once you have modified the ABAP Query, activate and generate it so that it will internally regenerate the a standard program.
http://help.sap.com/erp2005_ehp_02/helpdata/en/d2/cb4256455611d189710000e8322d00/frameset.htm
ABAP Query (Sq01)Modification
Hope this helps
Regards,
Shiva
Maybe you are looking for
-
Safari won't open after OS 10.4 software update combo update
I am working on a computer iMac g5 1.8ghz, 600 mhz Bus, 512mb Ram was 10.3.9 but Safari was not working because Safari 3.1.1 was installed. I tried removing all safari, cache, plist to no avail, Firefox worked after reinstall. I remove safari and upg
-
HT1369 my computer no longer recognises my iPhone 5c when its connected
hi, when i connect my iphone to my pc, itunes no longer recognises that a device is connected and therefore unable to sync, etc.
-
How to access custom labels in Table?
In IDML I have set up custom lables inside Table element. How can I access those labels? Thx!
-
Trial version of Acrobat X Standart
Hi, I need to try and see if Acrobat X Standart is enough or not for me. So I need to get a link for trial version of Acrobat X Standart. Regards.
-
"No entry in the table T589A for P" in PPOME's custom Tab
Hello, <u>requisites:</u><b> Add one custom Tab to transaction PPOME relative to Position (Object type S)</b> <u>problem:</u><b>"No entry in the table T589A for P" </b> when entering the transaction PPOME, and choose my new added Tab.</b> I get this