Dear friends,
I need to increase no. of processes.
Kindly anybody tell me the proces how to icrease it?
Thanx in advance.
Prashant T.

do you use a pfile or spfile, sysdba privileges are needed
to tell:
SQL> show parameter spfile
NAME TYPE VALUE
spfile string $ORACLE_HOME/dbs/spfilehmdw10.ora
if you get a value u have spfile
spfile:
alter system set processes=151 scope=spfile;
stop start db.
pfile:
edit your init.ora file parameter process=new value
stop start db.
Note: The default values of the SESSIONS and TRANSACTIONS parameters are derived from this parameter. Therefore, if you change the value of PROCESSES, you should evaluate whether to adjust the values of those derived parameters.
Message was edited by:
Slater

Similar Messages

  • How to increase the per-process file descriptor limit for JDBC connection 15

    If I need JDBC connection more that 15, the only solution is increase the per-process file descriptor limit. But how to increase this limit? modify the oracle server or JDBC software?
    I'm using JDBC thin driver connect to Oracle 806 server.
    From JDBC faq:
    Is there any limit on number of connections for jdbc?
    No. As such JDBC drivers doesn't have any scalability restrictions by themselves.
    It may be it restricted by the no of 'processes' (in the init.ora file) on the server. However, now-a-days we do get questions that even when the no of processes is 30, we are not able to open more than 16 active JDBC-OCI connections when the JDK is running in the default (green) thread model. This is because the no. of per-process file descriptor limit exceeded. It is important to note that depending on whether you are using OCI or THIN, or Green Vs Native, a JDBC sql connection can consume any where from 1-4 file descriptors. The solution is to increase the per-process file descriptor limit.
    null

    maybe it is OS issue, but the suggestion solution is from Oracle document. However, it is not provide a clear enough solution, just state "The solution is to increase the per-process file descriptor limit"
    Now I know the solution, but not know how to increase it.....
    pls help.

  • A document with more no of sheets seem to work very slow in pages. How to increase speed of processing

    A document with more no of sheets in it seems to work slow. Speed of processing is dull. An error message ( error code 43 ) appeared while working in pages.

    Also, try holding down the Command and the R keys
    during boot to get into the Recovery HD.  From there
    select Disk Utility and perform a Repair Pemissions
    and a Repair Disk on the OSX install partition.
    If that doesn't help, you may want to get some additional
    test and/or repair software to check the hard disk and
    other hardware.  Tech Tool Pro comes to mind, as it
    can run tests on various hardware aspects of the system.
    Disk Warrior is another program that can test file systems
    and look for file corruption.  You should be able to get
    these programs on line depending on where you are.
    This sounds suspiciously like file corruption going on
    which can be software caused or a hard disk that is
    starting to go bad or just a few sectors that went bad
    is some key spots.
    Going back to Snow Leopard will not help if there are
    are problems with the files or, hopefully not, the hard disk.

  • How to increase No. of Connections in Oracle DB?

    Hi,
    As my team using more no. of connections, I need to increase the number of connections.
    Kindly guide me to check the current number of connections and how to change / increase that?
    As I don't have knowledge on this, I am looking the detailed input on this.
    Kindly guide me, How to check the no. of connections in DB and how to increase that?
    Thanks in advance,
    Orahar.

    Orahar wrote:
    As my team using more no. of connections, I need to increase the number of connections.For what type of sessions? That determines whether dedicated or shared server sessions on the Oracle server can be used. Shared server scales a lot better than dedicated servers, but requires specific factors to be taken into consideration (e.g. the move of session UGA from the PGA to the SGA, dispatchers required, etc).
    For what server o/s? Windows deal differently with dedicated and shared servers (threads) as Unix/Linux (processes) do.
    And why the increase in connections required by your team? Are they using the Oracle server architecture correctly from the client side?
    Most 64bit Oracle severs can easily support 1000's of connections (shared server) - but the number of connections are secondary to how the clients are using their Oracle sessions.

  • How to increase the row and Column length of Bex query in EP Portal 7.3

    Dear All,
    Please let me know the process  to Increase the Rows and Columns  Size of Bex Query in Enterprise Portal  of SAP  7.3 .
    Please  let settings to increase rows up 10000 and column 100 in one page.
    Thanks
    Regards,
    Sai

    Dear All,
    Please find the attached screen shot.
    The report be open with 4 or 5 columns and 5 or 6 rows.
    So, please  let me know how to increase the length of the table.
    Do the needful for me to over come this issue.
    Thanks
    Regards,
    Sai.

  • How to increase memory allowed for an application

    Before in OS 9 and below we can expand the quantity of memory for an application, we can't do same in OS X.
    OS X is able to set himself the amount of memory for an application. This seems to work but I think there is a limit sets by OS X.
    My question is how to increase this amount of memory ?
    I tried to increase it in terminal using "ulimit -d unlimited" but this is not working enough.
    I use to do calculation with matrix systems and iterations in Mapple software but on my iMac with 4 GB of RAM memory, when application reaches 450 MB, I get a memory error message. Activity monitor at same time says there is more than 2 GB free !
    Has somebody a solution to free this limit, even for a small time or for only an application ?
    Thanks for your help.

    The full message is :
    "Kernel connection has been lost. The kernel returned the following message :
    Execution stopped : Memory allocation failed.
    Please sea ?alloc for more detail.
    You should save this worksheet and restart Maple
    Executing commands in Mapple requires a connection to the Maple kernel.
    Firewalls have been known to cause problems with kernel connections in Maple. Please ensure that any firewall software is configured to allow Maple to create connections to the kernel. Consul the FAQ for more information."
    I checked the firewalls of OS X, they are shutdown and no restrictions seems to be set for processes.
    We are expecting for a new version of Maple with some modifications due to Snow.

  • How to increase the waiting time for response in Adapter Engine not in IE

    Hi Experts,
                It is a SOAP to Proxy Synchronous interface. SOAP system is sending the request to PI, PI sending the same request to ECC system, After execution of some logic response back to PI in 7 minutes. In ABAP Stack(sxmb_moni) processing the response message also successfully with success flag after completion of these 7 minutes. But exactly 5 minutes later getting the error at Java Stack RWB- in communication channel monitoring i.e
    com.sap.engine.interfaces.messaging.api.exception.MessagingException: com.sap.engine.interfaces.messaging.api.exception.MessageExpiredException: Message bd2bf8d0-b2c2-11e0-c383-001cc4fb5cb7(OUTBOUND) expired.  We have set the "runtime-HTTP_TIMEOUT" parameter as 3600. thats why in Integration engine it is processing successfully.
    kindly suggest me how to increase the waiting time for response in Adapter Engine. Exactly after 5 mins getting the above error in rwb, but in Integration Engine getting successful flag after 7 mins until then it is waiting for response with  status flag Log version.
    Thanks & Regards,
    Srihari.

    Hi,
    Please see
    How To... Investigate Timeouts In Synchronous XI/PI Scenarios
    It will answer all your queries
    http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/c059d583-a551-2c10-e095-eb5d95e03747?QuickLink=index&overridelayout=true

  • How to increase the files picked up by File Adaptor per poll interval

    Hi,
    We have a scenario where in we post 80 files in the source directory and and the file adapter is configured for every 300 sec but i have noticed that the File adaptor is picking up one or two files per poll interval.Can some please suggest how to increase the number of files picked up by File adaptor
    Thank You,
    Nandini

    Nandini:
    Did you mention all the files names in the Adapter channel. One thing you can do is use wild cards and file adapter picks most of them
    /people/mickael.huchet/blog/2006/09/18/xipi-how-to-exclude-files-in-a-sender-file-adapter
    In case if your files are huge, then I guess file size may cause to process few files during each poll

  • How to increase the number of files picked up by File adaptor

    Dear all,
    Can any one tell me how to increase the number of files picked up by File adapter.
    Pl post ASAP.
    Useful answers will be appreciated accordingly.
    Thanks,
    Srinivas

    Hi Srinivasa,
    there is no parameter for number of files to be picked..............if you have too many source files and you want to get them processed quickly, then you can specify a very small polling interval, then XI will pick your source files quickly..........but it will cause heavy load on the XI system which can lead to blockage of messages in queues........
    Regards,
    Rajeev Gupta

  • How to Increase the Length of Condition table in OV20

    While creating a condition table in T.code OV20 if fields length is more that 50 bytes table is not getting generated.it gives error as Too Many Fields Selected(More than 50 Bytes).
    Actually i need to create a tabel with Basic Material(WRKST) which has length of 48 bytes.
    Is there a solution on how to increase the length so that error is avoided.
    There is no such error occuring while crating condition table in V/03

    Hi,
         You can try to use the type string:
    form like zscr_data_hdr-form,
    werks like zscr_data_hdr-werks,
    matnr like zscr_data_hdr-matnr,
    verid like zscr_data_hdr-verid,
    lot like zscr_data_hdr-lot,
    lot_qty like zscr_data_hdr-lot_qty,
    udate like zscr_data_hdr-udate,
    utime like zscr_data_hdr-utime,
    zuser like zscr_data_hdr-zuser,
    processed like zscr_data_hdr-processed,
    defect like zscr_defect_data-defect,
    vornr like zscr_route_data-vornr,
    fieldxx type string,
    dayst like zscr_data_hdr-dayst,
    end of t_data.
    So you can save you informations of every fld<n> concatenating their values into fieldxx.
    Regards

  • How to increase the length of internal table dynamically

    How to increase the length of internal table dynamically depending on the number of fields fetched into the internal table ?
    The requirement code :
    types: begin of t_data,
             form          like zscr_data_hdr-form,
             werks         like zscr_data_hdr-werks,
             matnr         like zscr_data_hdr-matnr,
             verid         like zscr_data_hdr-verid,
             lot           like zscr_data_hdr-lot,
             lot_qty       like zscr_data_hdr-lot_qty,
             udate         like zscr_data_hdr-udate,
             utime         like zscr_data_hdr-utime,
             zuser         like zscr_data_hdr-zuser,
             processed     like zscr_data_hdr-processed,
             defect        like zscr_defect_data-defect,
             vornr         like zscr_route_data-vornr,
             fld1          like zscr_defect_data-defect_val,
             fld2          like zscr_defect_data-defect_val,
             fld3          like zscr_defect_data-defect_val,
             fld4          like zscr_defect_data-defect_val,
             fld5          like zscr_defect_data-defect_val,
             fld6          like zscr_defect_data-defect_val,
             fld7          like zscr_defect_data-defect_val,
             fld8          like zscr_defect_data-defect_val,
             fld9          like zscr_defect_data-defect_val,
             fld10         like zscr_defect_data-defect_val,
             fld11         like zscr_defect_data-defect_val,
             fld12         like zscr_defect_data-defect_val,
             fld13         like zscr_defect_data-defect_val,
             fld14         like zscr_defect_data-defect_val,
             fld15         like zscr_defect_data-defect_val,
             fld16         like zscr_defect_data-defect_val,
             fld17         like zscr_defect_data-defect_val,
             fld18         like zscr_defect_data-defect_val,
             fld19         like zscr_defect_data-defect_val,
             fld20         like zscr_defect_data-defect_val,
             fld21         like zscr_defect_data-defect_val,
             fld22         like zscr_defect_data-defect_val,
             fld23         like zscr_defect_data-defect_val,
             fld24         like zscr_defect_data-defect_val,
             fld25         like zscr_defect_data-defect_val,
             fld26         like zscr_defect_data-defect_val,
             fld27         like zscr_defect_data-defect_val,
             fld28         like zscr_defect_data-defect_val,
             fld29         like zscr_defect_data-defect_val,
             fld30         like zscr_defect_data-defect_val,
             fld31         like zscr_defect_data-defect_val,
             fld32         like zscr_defect_data-defect_val,
             fld33         like zscr_defect_data-defect_val,
             fld34         like zscr_defect_data-defect_val,
             fld35         like zscr_defect_data-defect_val,
             fld36         like zscr_defect_data-defect_val,
             fld37         like zscr_defect_data-defect_val,
             fld38         like zscr_defect_data-defect_val,
             fld39         like zscr_defect_data-defect_val,
             fld40         like zscr_defect_data-defect_val,
             fld41         like zscr_defect_data-defect_val,
             fld42         like zscr_defect_data-defect_val,
             fld43         like zscr_defect_data-defect_val,
             fld44         like zscr_defect_data-defect_val,
             fld45         like zscr_defect_data-defect_val,
             fld46         like zscr_defect_data-defect_val,
             fld47         like zscr_defect_data-defect_val,
             fld48         like zscr_defect_data-defect_val,
             fld49         like zscr_defect_data-defect_val,
             fld50         like zscr_defect_data-defect_val,
             fld51         like zscr_defect_data-defect_val,
             fld52         like zscr_defect_data-defect_val,
             fld53         like zscr_defect_data-defect_val,
             fld54         like zscr_defect_data-defect_val,
             fld55         like zscr_defect_data-defect_val,
             fld56         like zscr_defect_data-defect_val,
             fld57         like zscr_defect_data-defect_val,
             fld58         like zscr_defect_data-defect_val,
             fld59         like zscr_defect_data-defect_val,
             fld60         like zscr_defect_data-defect_val,
             fld61         like zscr_defect_data-defect_val,
             fld62         like zscr_defect_data-defect_val,
             fld63         like zscr_defect_data-defect_val,
             fld64         like zscr_defect_data-defect_val,
             fld65         like zscr_defect_data-defect_val,
             fld66         like zscr_defect_data-defect_val,
             fld67         like zscr_defect_data-defect_val,
             fld68         like zscr_defect_data-defect_val,
             fld69         like zscr_defect_data-defect_val,
             fld70         like zscr_defect_data-defect_val,
             fld71         like zscr_defect_data-defect_val,
             fld72         like zscr_defect_data-defect_val,
             fld73         like zscr_defect_data-defect_val,
             fld74         like zscr_defect_data-defect_val,
             fld75         like zscr_defect_data-defect_val,
             fld76         like zscr_defect_data-defect_val,
             fld77         like zscr_defect_data-defect_val,
             fld78         like zscr_defect_data-defect_val,
             fld79         like zscr_defect_data-defect_val,
             fld80         like zscr_defect_data-defect_val,
             fld81         like zscr_defect_data-defect_val,
             fld82         like zscr_defect_data-defect_val,
             fld83         like zscr_defect_data-defect_val,
             fld84         like zscr_defect_data-defect_val,
             fld85         like zscr_defect_data-defect_val,
             fld86         like zscr_defect_data-defect_val,
             fld87         like zscr_defect_data-defect_val,
             fld88         like zscr_defect_data-defect_val,
             fld89         like zscr_defect_data-defect_val,
             fld90         like zscr_defect_data-defect_val,
             fld91         like zscr_defect_data-defect_val,
             fld92         like zscr_defect_data-defect_val,
             fld93         like zscr_defect_data-defect_val,
             fld94         like zscr_defect_data-defect_val,
             fld95         like zscr_defect_data-defect_val,
             fld96         like zscr_defect_data-defect_val,
             fld97         like zscr_defect_data-defect_val,
             fld98         like zscr_defect_data-defect_val,
             fld99         like zscr_defect_data-defect_val,
             fld100         like zscr_defect_data-defect_val,
             fld101         like zscr_defect_data-defect_val,
             fld102         like zscr_defect_data-defect_val,
             fld103         like zscr_defect_data-defect_val,
             fld104         like zscr_defect_data-defect_val,
             fld105         like zscr_defect_data-defect_val,
             fld106         like zscr_defect_data-defect_val,
             fld107         like zscr_defect_data-defect_val,
             fld108         like zscr_defect_data-defect_val,
             fld109         like zscr_defect_data-defect_val,
             fld110         like zscr_defect_data-defect_val,
             fld111         like zscr_defect_data-defect_val,
             fld112         like zscr_defect_data-defect_val,
             fld113         like zscr_defect_data-defect_val,
             fld114         like zscr_defect_data-defect_val,
             fld115         like zscr_defect_data-defect_val,
             fld116         like zscr_defect_data-defect_val,
             fld117         like zscr_defect_data-defect_val,
             fld118         like zscr_defect_data-defect_val,
             fld119         like zscr_defect_data-defect_val,
             fld120         like zscr_defect_data-defect_val,
             fld121         like zscr_defect_data-defect_val,
             fld122         like zscr_defect_data-defect_val,
             fld123         like zscr_defect_data-defect_val,
             fld124         like zscr_defect_data-defect_val,
             fld125         like zscr_defect_data-defect_val,
             fld126         like zscr_defect_data-defect_val,
             fld127         like zscr_defect_data-defect_val,
             fld128         like zscr_defect_data-defect_val,
             fld129         like zscr_defect_data-defect_val,
             fld130         like zscr_defect_data-defect_val,
             fld131         like zscr_defect_data-defect_val,
             fld132         like zscr_defect_data-defect_val,
             fld133         like zscr_defect_data-defect_val,
             fld134         like zscr_defect_data-defect_val,
             fld135         like zscr_defect_data-defect_val,
             dayst         like zscr_data_hdr-dayst,
           end of t_data.
    In this fld1 to fld135 are defined in internal table.
    But if the number of fields are more than 135 then the program is going to short dump.
    Some times fld1 to fid170 or more fields will be there in my internal table.
    Please suggest me how to make my requirement dynamic and display this data fetched into this internal table onto a .XLS file in the presentation server ?

    Hi
    You can try to use the type string:
    form like zscr_data_hdr-form,
    werks like zscr_data_hdr-werks,
    matnr like zscr_data_hdr-matnr,
    verid like zscr_data_hdr-verid,
    lot like zscr_data_hdr-lot,
    lot_qty like zscr_data_hdr-lot_qty,
    udate like zscr_data_hdr-udate,
    utime like zscr_data_hdr-utime,
    zuser like zscr_data_hdr-zuser,
    processed like zscr_data_hdr-processed,
    defect like zscr_defect_data-defect,
    vornr like zscr_route_data-vornr,
    fieldxx type string,
    dayst like zscr_data_hdr-dayst,
    end of t_data.
    So you can save you informations of every fld<n> concatenating their values into fieldxx.
    Max

  • How to increase the limit of maximim connections that the iMS will accept

    how to increase the limit of maximim smtp connections that the iMS will accept & route the mails for specific domain on different mta like iMS will accpet mails on 192.168.1.5|25 & route all @mydomain.com's mails towards 192.168.1.55|25. although I am able to route the mails but to know how to increase the limit of maximum connection & maximum chiild processes per connection.
    Thanks

    Best thing for you to do is read the tuning guide, found here:
    http://ims.balius.com/downloads.php#tuning_guide
    Please note, this site does not work with IE. It's not a Sun site, but has the best tuning guide available.
    You may end up increasing maxjobs for your channels, increasing the POOL that the jobs are pulled from, etc. It's all well covered in the guide, as are some OS related tuning tips.
    Strongly recommended.

  • How to determine the Parent process information in Oracle BPMS 10g

    Hi ,
    I am trying to retrieve the parent process information given the instanceId and Process Id of an instance of a process from a different process.
    I am getting the instanceId of the instance in workspace using the Fuego.Papi.ProcessService and by creating the Filter.
    I tried using the ProcessInstance.parent but it needs to be instantiated using the instance details of my referred instance, which i am not able to do.
    Can some one shed some light on how to get the parent process details from the referred instance.
    Thanks,
    shravan.

    Hi,
    If you mean to increase the request timeout i.e the time when a request is submitted to the server and the response is sent by the server it can be done in httpd.conf file located in $OracleHome/Apache/Apache/conf directory.
    The attribute to be used for setting timeout is "Timeout". By default teh value is 600 seconds i.e 5 minutes.
    After making these changes , run command dcmctl updateConfig -ct OHS and restart the HTTP Server. Please note these commands need to be run only if the httpd.conf changes are done through text editor.
    Hope this helps.
    Smita

  • How to increase the number of data Business Object can pull for a report?

    Hi,
    I would like to ask around how to increase the number of data Business Object can pull for a report. I have a report which pulls data depending on the date range (ex. From 01/01/2007 - 01/10/2007). But, when the data that is pulled exceeds 5000, the report fails. Is there anyway to increase the number of data that BO can pull?
    Thanks

    Bobby,
       to my knowledge we can't change that. Let me explain this, we have setting in the source system for DS default Data Transfer. there we will assign the processes. if you want to assign 4 you need to change the setting in the source system. For flat files we can change in BW System. We can maintain the setting in the Infopackage level(wht we are assigned in the Source System), but we can't change the process.
    in order to check the setting in source system  SBIW--> General Settings --> Control Parameters for Data Transfer.
    we need to change here, this will effect to all the Data Sources. Before making changes check with your basis.
    All the best.
    Regards,
    Nagesh Ganisetti.

  • How to Increase the retreving size of instances using PAPI filters.

    Hi,
    How to Increase the retreving size of instances using PAPI filters.
    In my engine database instance size exceeds 2500 then we are getting following exception.
    If we login in to user workspace able to see the instances but while trying to retrieve from PAPI getting below exception and showing the user's inbox aize as 0.
    In Process Admin console we set all the required parameters.
    Still I m getting the same problem.
    Can you please lgive mev the solution.
    <Mar 23, 2010 8:58:24 PM SGT> <Warning> <RMI> <BEA-080003> <RuntimeException thrown by rmi server: fuego.ejbengine.EJBProcessControl_1zamnl_EOImpl.getInstancesByFilter(Lfuego.papi.impl.j2ee.EJBSecureEngineInfo;Ljava.lang.String;Lfuego.papi.Filter;)
    java.lang.ClassCastException: cannot assign instance of java.util.HashSet to field fuego.view.FilterImpl.attributes of type java.util.List in instance of fuego.view.FilterImpl.
    java.lang.ClassCastException: cannot assign instance of java.util.HashSet to field fuego.view.FilterImpl.attributes of type java.util.List in instance of fuego.view.FilterImpl
         at java.io.ObjectStreamClass$FieldReflector.setObjFieldValues(ObjectStreamClass.java:2032)
         at java.io.ObjectStreamClass.setObjFieldValues(ObjectStreamClass.java:1212)
         at java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:1953)
         at java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:1871)
         at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1753)
    Regards,
    Bharath.
    Edited by: bg57295 on Mar 24, 2010 6:45 PM

    Hi Bharath,
    Believe me, you have an incompatibility between different build#.
    PAPI has an instance cache. When certain process has more instances than the maximum specified, the cache is switch to status OPEN. That means, that PAPI will not be able to resolve some instance queries using the information in the cache. When that occurs, PAPI forward all those queries to the engine.
    The incompatibility introduced is in the communication between PAPI and Engine. So, you only get the exception when you have more instances than the maximum cache size.
    Regards,
    Ariel

Maybe you are looking for

  • Help needed with sending XML data out of Dashboard design/ Xcelsius

    Hi All, I did this a year back and got it right, but now am not able to get it, probably Ive made a small mistake which I have been overlooking. I selcted Enable XML send in my XML data connection and dfined the connection name as "Range_1" and Range

  • TS2301 microsoft word won't open in 10.7

    Microsoft Word won't open in 10.7.  What to do?

  • Why will Verizon not allow the use of a phone number that is Not a Verizon Number?

    Not happy with Verizon! No alerts sent to iPad, no phone numbers other than Verizon numbers. Why? Options 09-29-2011 02:17 AM Ok, I have been on the phone twice now with customer support, all I want is an alert sent to my IPad for data usages ! I wan

  • Development class Usage

    Hi,     I have created one development class (package) in ECC 6.0 IDES server,pcakge name is ZXYZ, but when i am trying to save the objects in this package , it is giving the error message 'Package cannot be extended'. Please  help me in this regard.

  • Dreamweaver CS3 Flash Prof CS3 and the web

    I am a beginner web designer, but I have search for this answer for DAYS now! I have placed flash in a html file in Dreamweaver CS3. I have tried to get it to show up on the web to no avail. It plays fine in Dreamweaver, but doesn't show up in the pr