HOW to load Master data

Can I not load Master data, that is Text directly to infoObject.
Now I load Text to a custom infoObject from a flat file.
Infopack puts data in PSA, Then dont I need a DTP to put data into infoObject.
Now when I try to create DTP it will say it will need a transformation and it will create it. Now when U execute DTP it is failing because infoObject is not an inforprovider.
Once InfoObject is in an infoarea that it is good to go.
Now I dont want the infoObject to be infoprovider. How can I load directly to master data tables of the infoObjects.

Hi GMAN
In BI7.0, You can use "Old" data source, that can upload into master data directly.
If you want to use "Old" one, change back your data source to 3.x data source.
For more details, see below links.
Datasource or Datasource 3.x
Hanna

Similar Messages

  • How to load master data from SAP R/3 system like Customer master...........

    How to load master data from SAP R/3 system like Customer master, materioal master , vendor master.............

    Hi Bramha,
            Check ...........
    Re: master data loading in BI 7.0
    /message/4708129#4708129 [original link is broken]
    Re: Master data loading.
    Regards,
    Vijay.

  • How to load master data in sap bpc 7.0

    Hi ,
      how to load master data in sap bpc 7.0?plz give me the steps also?
    Thank u

    Hello Devi,
    There are three ways you can load Master Data in BPC
    1) Copy and paste.
    Download master data in flat file .Copy the  master data and paste in members of dimension after that process the dimension.
    2) Using SISS Pakage - load Flat File into BPC-Cube
    3) Using SQL Command.
    Thanks.
    With regards,
    Anand Kumar

  • How to load master data in bpc 10

    HIi All,
    Could any one please share some documents/PDF  or any link with me as how to load master data in BPC 10 Nw.
    Regards
    Bhupendra Arya

    Bhupendra,
    There are many docs/threads related to this in SDN, pls check.
    SAP BPC NW 10.0 Master Data Load to BPC from BW | SAP BPC Discussions
    Hope this helps..

  • How to load master data texts for (0calmonth)

    Hi pro's
    i hve a issue.
    How to load master data texts for 0calmonth.
    any help is appreciated
    regards
    cheers

    within the admin workbench goto source systems, right click on your source system and click on transfer global settings. There you can choose fiscal year variants and some other options to be loaded to BW.
    Regards

  • How to load master data and hierarchies from R/3 systems

    HI all,
    how to load master data and hierarchies from R/3 systems.
    Please explain the steps.
    Thanks,
    cheta.

    HI,
    Its normally done following: Transferring the master datasources in RSA5 to RSA6 and then replicating the DS into BW and assignment of DS to Infosource and cretaion of Infopackage and load it into the master tables.
    Generally, the control parameters for data transfer from a source system are maintained in extractor
    customizing. In extractor customizing, you can access the corresponding source system in the source
    system tree of the SAP BW Administrator Workbench by using the context menu.
    To display or change the settings for data transfer at source system level, choose Business
    Information Warehouse → General Settings → Maintaining Control Parameters for Data Transfer.
    Note: The values for the data transfer are not hard limitations. It depends on the DataSource if these
    limits can be followed.
    In the SAP BW Scheduler, you can determine the control parameters for data transfer for individual
    DataSources. You can determine the size of the data packet, the number of parallel processes for
    data transfer and the frequency with which the status IDocs are sent, for every possible update
    method for a DataSource.
    To do so, choose Scheduler → DataSource → Default Settings for Data transfer.
    In this way you can, for example, update transaction data in larger data packets in the PSA. If you
    want to update master data in dialog mode, smaller packets ensure faster processing.
    Hope this info helps.
    Thanks,Ramoji.

  • How to load master data from 2 source system without using 0logsys as compo

    Hi Gurus,
    I am working on a project which has 2 source systems.
    Now I have to load master data from 2 source systems without making 0LOGSYS as compunding attribute. Because all the objects which i want to use compunding attribute are reference objects for lot of other info objects. So, i dont want to change the business content objects structure.
    So, please help me out providing logic.
    thanks in advance
    Peter.

    Hi Peter,
    Can you brief me how did you resolved your issue?
    Regards
    Utpal

  • How to load master data with text into infoObject in BI 7.0

    Hi all;
    I have an infoobject 0employee ( this is for employee number ,8 character long), with medium text option.
    I would like to load Employee name as a text option for employee number.
    How do I load this mater data into this 0employee object,
    Please help.
    I did look for something similar in the forum and there are many of them, but I couldn't find anything that for BI 7.0 and really clear help for me. Sorry to ask a question that been asked before.
    thanks.
    Raiine

    hi rainnie,
    check this link t oload master data in BI 7
    Re: BI 7.0 flat File extraction
    as you are using SAP defined infoobject you can start from the creation of datasource.
    text format for the flat file is
    LANGUAGE,INFOOBJECT,TEXT
    EN,0EMPLOYEE,RAINNIE
    You have to create ,infopakage, transformation ,dtp for both the attribute and text.
    hope this helps
    cheers
    Sunil

  • How to load master data hierarchy load from BI to BPC 7.5 NW

    Hi,
    I am testing master data hierarchy data upload from BI to BPC. However when i run master data hierarchy mport package, it's always displaying a warning message saying that  no records are returned from "Z_PFT_CTR" which is my info object name.
    My transformation is as below.
    0BUS_AREA=BUS_AREA
    0COMP_CODE=COMP_CODE
    0CO_AREA=CO_AREA
    0LOGSYS=LOGSYS
    0OBJ_CURR=OBJ_CURR
    0PROFIT_CTR=PROFIT_CTR
    0RESP_PERS=RESP_PERS
    0RESP_USER=RESP_USER
    Conversion is as below
    ID=ID_CONVERT.xls 
    PARENTH1=HARI.xls
    Hierarchy i have mapped in conversion file from Source Inforobject 1000PCDUMMY-1 to  BPC  PARENTH1 Destination.
    Any suggestions plz?

    Hi,
    Just follow the docs in "How Tou2026 Automate BPC 7.0, version for the NetWeaver Platform Master Data Loads from BW to BPC"
    where you will get detail step-by-step procedure to load data.
    Check the url:
    http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/00380440-010b-2c10-70a1-e0b431255827
    Before that you have to transport into BPC system the load to work fine.
    Thanks
    Debasisha

  • How to Load Master data text  Description into the Data Target?

    Hi,
    I have a Master data which is an ID, and the description for that ID is added as text description along with the master data.
    The datasource is a flat file load, which has both the fields i.e. ID as well as the description along with many other fields.
    I need to load the flat file without changing it, into the ODS.
    Please suggest a way to load the description of the ID along with the ID into the ODS, and then further into the CUBE.
    This description field should be available, while checking the contents of the ODS as well as the CUBE.

    hi Srinivas,
    Thanks for the quick response.
    I actually have the flat file with the description within it.
    I cannot make any changes to the flat file.
    So, please suggest me accordingly.

  • How to Load Master Data Text  from Multiple Source Systems

    Situation:  Loading vendor master (text) from two systems.  Some of the vendor keys/number are the same and so is the description.  I understand that if I was loading Attributes, I could create another attribute such a source system id and compound it to 0Vendor.  However, I don't believe you can do the same when loading text. 
    Question:  So, how can I load duplicate vendor keys and description into BW using the *_TEXT datasource so they do not overwrite?
    Thanks!

    Hi,
    Don't doubt, it'll work!
    Sys ID as compound to 0Vendor.
    If you doubt about predefined structure of the *_TEXT datasource and direct infosource, then use a flexible infosource. Maybe you'll have to derive the sys ID in a routine or a formula.
    Best regards,
    Eugene

  • Issue in loading master data in BI 7.0

    Hi,
    I fail to understand how to load master data in BI 7.0. Can you please fill in the steps.
    1. Created an Infoarea.
    2. Created 2 infoobject catalogs ( for char and kf)
    3. Created characteristics like empname and month and salary as KF.
    4. For empname, attached the attributes dept and address (master data).
    Now what steps should I follow to load master data of all employees and what should be my flat file format ?
    thanks

    RSA1 - D Cclick on FlatFile Source System - RClick on the App  Comp - Create Datasource of type - Master Data Attributes - Enter the required - Read the File in Extraction Tab - Field Tab - Add Infoobjects already Created under Infoobject Column - Check the Preview to see it shows data fine - Activate the datasource
    Create Transformation btn Datasource and Infobject - Activate it
    Create Infopackage on Master Attr Datsource - Run it
    Create DTP - Run it to load from PSA to IO

  • Error 194 while loading Master Data.

    Hi,
         I've a custom Info Object which has 0MATERIAL as an attribute. While trying to load master data to this custom info object using DBConnect , I'm getting the error:
    RSDMD 194
    0MATERIAL: Data record 1('0001003') : Version '1009841' is not valid.
    I think it's a problem with conversion exit. But I'm not able to solve this problem. It would be of great help if you could guide me on how to overcome this.
    Thanks in advance.
    Regards
    Hari

    Hari,
        I'm thinking for DB Connected datasources we have Propose Tab Page and Fileds Tab Page. In the Propose tab Page you can see data type and Format(internal or External or check). select external, put data type of your Material Infoobject Data type in the Propose Tab Page.
    all the best.
    Note: I'm thinking DB Connected Datasources got Propose Tab page. Please correct me if i'm wrong.
    Regards,
    Nagesh Ganisetti.
    *Assign Points if it helps

  • Error while loading master data from R/3

    Hi Friends,
                I'm just trying to load master data for the infoobject of type "0BUS_AREA", but i have got data into PSA, but not got into char, i have got an error stating that
    Record 1 :No source system ID exists for source system (logical system) RD1CLNT100
    In tran structure there are two objects not being populated 0LOGSYS & OSOURCESYSTEM, which might cause the problem.
    Pls waiting for your replays
    Thanx in advance
    Balaji K.

    Hi Aswin,
               Thanx for your replay, in that one column is there, "source system id" but it is empty, how to generate that two digit source system id and also there are three kind of tabs like
    "Release IDs that are in use" "Suggest Source System IDs" & "Maintain Logical Systems"
             How to use and which one to use, and how to follow step by step to run loads once again by populating "OLOGSYS" & "OSOURCESYSTEM" ?
    Pls clarify this problem
    Regards.,
    Balaji K.

  • 36 duplicate record  found. -- error while loading master data

    Hello BW Experts,
    Error while loading master data
    ( green light )Update PSA ( 50000 Records posted ) No errors
    ( green light )Transfer rules ( 50000  „³ 50000 Records ): No errors
    ( green light )Update rules ( 50000 „³ 50000 Records ): No errors
    ( green light ) Update ( 0 new / 50000 changed ): No errors
    ( red light )Processing end: errors occurred
         Processing 2 finished
    ƒÞ     36 duplicate record found. 15718 recordings used in table /BIC/PZMATNUM
    ƒÞ     36 duplicate record found. 15718 recordings used in table /BIC/XZMATNUM
    This error repeats with all the data-packets.
    what could be the reason of the error. how to correct the error.
    Any suggestions appreciated.
    Thanks,
    BWer

    BWer,
    We have exactly the same issue when loading the infoobject 0PM_ORDER, the datasource is 0PM_ORDER_ATTR.
    The workaround we have been using is 'Manual push' from the details tab of the monitor. Weirdly we don't have this issue in our test and dev systems, even in Production, this doesn't occur somedays. We have all the necessary settings enabled in the infopackage.
    Did you figure out a solution for your issue, if so please let me know and likewise I will.
    -Venkat

Maybe you are looking for

  • Applescript to suck ical dates into iweb

    I was referred to this forum from the iweb forum (http://discussions.apple.com/thread.jspa?threadID=2513935&tstart=0). Here's what I would like to do: I am an athletic director and would I have entered all of my school's athletic contests into iCal.

  • The power isnt working I NEED HELP PLEASE

    My macbook pro randomly turned off last night hasnt turned on since, it wont respond to charger and have tried SMC, HELP!!!!

  • Fn + space bar zoom not working in windows 7

    I upgraded my T60p 2007 U93 via a new install and now I no longer can change my screen resolution using the Fn + spacebar.  Any ideas as to how to reactivate this function?  I am running the newest bios and I think I have all the correct drivers. Sol

  • InDesign CS5 and Acrobat 8

    I am using ID 5 and Acrobat 8. My client marks up changes on a pdf for me to change the ID file. I used to be able to copy the text from the Acrobat file and simply paste it into the ID file. For some reason it wont do it. So I am having to type UGGG

  • IND CS2 SCALE STROKE ISSUE

    I am trying to scale a vector object pasted into CSIN2 form Illustrator CS2. I get an error message saying "requested operation would cause one or more objects to be too small. Please check whether the stroke is to large". There is no stroke at all o