How to pass a SELECT-OPTION to a FUNCTION-MODULE

Hi forum:
          How can i pass a selection-option like an input parameter of a function-module?. Put one example in the answer, please.
          After pass this value i want to put this into an IN select condition.
   But for i only need know how to pass this value
thnks
Josué
Thnks
Josue Cruz

Hi Rich.
   this is a little example of my code.
   DATA: wa_bukrs TYPE bkpf-bukrs,
              wa_budat TYPE bkpf-budat,
              wa_gjahr TYPE bkpf-gjahr.
   SELECT-OPTIONS: se_bukrs FOR wa_bukrs OBLIGATORY,
                se_gjahr FOR wa_gjahr OBLIGATORY,
                se_budat FOR wa_budat OBLIGATORY.
  HERE i can to put the call to the function.
Thnks

Similar Messages

  • How to pass select option value to function module while using service call

    Hi,
    I have select-option in my WD application. To collect data based on user input im using service call. How to pass this select option values to my RFC.
    rgds
    sudhanshu

    Hi,
    Thank s for your reply. In fact im doing similar with following variation:
    i) collected range values using get_range* method.
    ii) separate low and high values as: 
    read table <field2> index 1 into wa_range.
    vert2_low = wa_range-low.
    vert2_high = wa_range-high.
    (Please note that in RFC I have taken two importing parameter as s_vert_lo and s_vert_hi)
    iii) Now setting these RFC attribute as:
    lo_el_importing->set_attribute(
        EXPORTING
          name =  `S_VERT_LO`
          value = vert2_low ).
    and
    lo_el_importing->set_attribute(
        EXPORTING
          name =  `S_VERT_HI`
          value = vert2_high ).
    iv) In RFC im having my query as :
    select <fld list> from BUT000 into table itab where vertical in r_vert.
    Here, r_vert is a range defined as:
    ranges r_vert for <fld refrence>
    r_vert-sign = 'I'.
    r_vert-option = 'BT'.
    r_vert-low = S_VERT_LO.
    r_vert-high = S_VERT_HI.
    append r_vert.
    Issue here is with ranges. if im passing both low and high values it is fine but if only low value being passed it is not giving me any record.
    Please suggest.
    Rgds
    Sudhanshu

  • How to pass select-option filed to Function Module Exporting Parameter

    Hi,
        How to pass select-option filed to Function Module Exporting Parameter.
    Thanks

    Hi,
    DATA: BEGIN OF ITAB5_WRK OCCURS 0,
            KUNNR     TYPE KNKK-KUNNR,  "CUSTOMER #
            SBGRP     TYPE KNKK-SBGRP,  "CREDIT REP
            KLIMK     TYPE KNKK-KLIMK,  "CREDIT LIMIT
            NAME1     TYPE KNA1-NAME1,  "CUSTOMER NAME
            SKFOR     TYPE KNKK-SKFOR,  "TOTAL A/R
            AMT1      TYPE KNKK-SKFOR,  "CURRENT
            AMT2      TYPE KNKK-SKFOR,                          "01-30
            AMT3      TYPE KNKK-SKFOR,                          "31-60
            AMT4      TYPE KNKK-SKFOR,                          "61-90
            AMT5      TYPE KNKK-SKFOR,                          "91-120
            AMT6      TYPE KNKK-SKFOR,                          "OVR 120
            BZIRK     TYPE KNVV-BZIRK,
          END OF ITAB5_WRK.
    SELECT-OPTIONS P_COMP     FOR  T001-BUKRS
      SELECT KUNNR SBGRP  FROM KNKK
             INTO TABLE ITAB5_WRK
             WHERE SBGRP IN P_REP
               AND KUNNR GE '0001000000'
               AND SKFOR NE 0.
      LOOP AT ITAB5_WRK.
        DELETE ADJACENT DUPLICATES FROM ITAB5_WRK COMPARING KUNNR.
      ENDLOOP.
      PERFORM GET_CREDIT_LIMITS.
    *=======================================================================
      IF P_DIST NE SPACE.
        LOOP AT ITAB5_WRK.
          SELECT SINGLE * FROM KNVV WHERE KUNNR EQ ITAB5_WRK-KUNNR
                                      AND VKORG EQ P_COMP
                                      AND VTWEG EQ '20'
                                      AND SPART EQ '10'
                                      AND BZIRK IN P_DIST.
          IF SY-SUBRC EQ 0.
            MOVE KNVV-BZIRK TO ITAB5_WRK-BZIRK.
            MODIFY ITAB5_WRK.
          ELSE.
            DELETE ITAB5_WRK.
          ENDIF.
        ENDLOOP.
      ENDIF.
    *==============================================================
      LOOP AT ITAB5_WRK.
        MOVE: 'F/S'            TO WRK-KKBER,
               ITAB5_WRK-KUNNR TO WRK-KUNNR.
        PERFORM AGING.
        ADD: W_SNFAE  TO ITAB5_WRK-AMT1,
             W_SFAE1  TO ITAB5_WRK-AMT2,
             W_SFAE2  TO ITAB5_WRK-AMT3,
             W_SFAE3  TO ITAB5_WRK-AMT4,
             W_SFAE4  TO ITAB5_WRK-AMT5,
             W_SFAE5  TO ITAB5_WRK-AMT6,
             W_SFAEL  TO ITAB5_WRK-SKFOR,
             W_SNFAE  TO ITAB5_WRK-SKFOR.
        MOVE: 'SPEC'            TO WRK-KKBER,
               ITAB5_WRK-KUNNR TO WRK-KUNNR.
        *PERFORM AGING.*
        ADD: W_SNFAE  TO ITAB5_WRK-AMT1,
             W_SFAE1  TO ITAB5_WRK-AMT2,
             W_SFAE2  TO ITAB5_WRK-AMT3,
             W_SFAE3  TO ITAB5_WRK-AMT4,
             W_SFAE4  TO ITAB5_WRK-AMT5,
             W_SFAE5  TO ITAB5_WRK-AMT6,
             W_SFAEL  TO ITAB5_WRK-SKFOR,
             W_SNFAE  TO ITAB5_WRK-SKFOR.
        MODIFY ITAB5_WRK.
      ENDLOOP.
    FORM AGING.
      *CALL FUNCTION 'CUSTOMER_DUE_DATE_ANALYSIS'* 
      EXPORTING
          BUKRS             = P_COMP           
          KKBER             = WRK-KKBER
          KUNNR             = WRK-KUNNR
          RASID             = 'FEND'
          KLIMP             = 'X'
        IMPORTING
          SFAE1             = W_SFAE1
          SFAE2             = W_SFAE2
          SFAE3             = W_SFAE3
          SFAE4             = W_SFAE4
          SFAE5             = W_SFAE5
          SFAE6             = W_SFAE6
          SFAEL             = W_SFAEL
          SNFA1             = W_SNFA1
          SNFA2             = W_SNFA2
          SNFA3             = W_SNFA3
          SNFA4             = W_SNFA4
          SNFA5             = W_SNFA5
          SNFA6             = W_SNFA6
          SNFAE             = W_SNFAE
        EXCEPTIONS
          NO-AGING_SCHEDULE = 1
          NO_TABLE_INPUT    = 2.
      CASE SY-SUBRC.
        WHEN 1.
          MESSAGE E999 WITH 'PLEASE ENTER AGING SCHEDULE'.
        WHEN 2.
          MESSAGE E999 WITH 'DO NOTHING ??'.
      ENDCASE.
    ENDFORM.                    "AGING
    Thanks

  • How to use select-options in the function module of import parameter ?

    Hi ...
       I have created a BAPI and tested in SWO1 tcode , by giving the single value for an company code ( BUKRS ) , it executed properly .
    Same thing is working after implementing in a program .
    so now it is working for fetching a single company code details .
    My requirement is : I want to use select-options in program as well as in function module IN IMPORT PARAMETER.
    Program :
    REPORT  ZTEST.
    TABLES : T001 , ZBAPI_STR .
    TYPES : BEGIN OF TY_ITEM  .
              INCLUDE STRUCTURE ZBAPI_STR .
    TYPES : END OF TY_ITEM .
    DATA :WA_ITEM TYPE TY_ITEM ,
          ITEM LIKE STANDARD TABLE OF WA_ITEM INITIAL SIZE 0 .
    PARAMETER : BUKRS TYPE ZBAPI_STR-BUKRS.
    call function 'ZBAPI_FMT001'
      exporting
        bukrs         =  BUKRS
    IMPORTING
      RETURN        =
      tables
        itemtab       = ITEM
    IF ITEM IS NOT INITIAL .
      LOOP AT ITEM INTO WA_ITEM .
        WRITE : / WA_ITEM-BUKRS , WA_ITEM-BUTXT , WA_ITEM-ORT01 , WA_ITEM-LAND1 .
      ENDLOOP.
    ENDIF.
    FUNCTION MODULE :
    FUNCTION ZBAPI_FMT001.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(BUKRS) TYPE  EFG_TAB_RANGES
    *"  EXPORTING
    *"     VALUE(RETURN) TYPE  BAPIRET2
    *"  TABLES
    *"      ITEMTAB STRUCTURE  ZBAPI_STR
    SELECT BUKRS BUTXT ORT01 LAND1 FROM T001 INTO TABLE ITEMTAB WHERE BUKRS = BUKRS .
    ENDFUNCTION.
    Regards
    Deepa.

    I have given a similiar example which i did
    Declare a
    Table type:Z_TT_PONUM             
    Short text  :  Select options  PO Number
    in SE11 tcode with row type eg: Z_ST_PONUM
    create a structure (this will be the row type)
    Structure          Z_ST_PONUM            
    Short text         Select Options Field PO number
    Compenent  Compent type
    SIGN       BAPISIGN      Inclusion/exclusion criterion SIGN for range tables
    OPTION       BAPIOPTION      Selection operator OPTION for range tables
    LOW       EBELN                      Purchasing Document Number
    HIGH       EBELN                      Purchasing Document Number
    In the function module import
    give as
    I_PO_NUM     TYPE     Z_TT_PONUM     opt  pass value Select options  PO Number
    Hope this is exactly what you want to know.
    So you create a structure simliar to mine but the low an high whould be your component
    then a table type  and then include that in the BAPI.
    Then pass your select-option value to this BAPI when you call this BAPI in the program

  • Passing SELECT-OPTIONS value to Function Module

    Hi,
    I need to pass select-options value to a function module.
    Code is like the following:
    SELECT-OPTIONS seltab FOR object-type.
    CALL FUNCTION 'Z_MY_FM'
          EXPORTING
            sel_tab         = seltab
         IMPORTING
            result_tab     = it_result
    I have found a similar problem in the SDN forum: How to pass select-options parameter to FM?
    However, that could not help me much in solving my problem.
    So far I have tried to created a structure in DDIC with the following components for the select-options:
    SIGN - BAPISIGN
    OPTION - BAPIOPTION
    LOW - ZBWOBJECTTYPE (my type)
    HIGH - ZBWOBJECTTYPE (my type)
    and subsequently a table type for this structure which is specified in the "Import" tab of my function module.
    Unfortunately, when I ran the program a runtime exception occured (CALL_FUNCTION_CONFLICT_TYPE).
    Could anyone please help me on this issue?
    Thanks in advance.
    Regards,
    Joon Meng

    Hello Joon,
    CALL FUNCTION 'Z_MY_FM'
          EXPORTING
            sel_tab         = seltab
         IMPORTING
            result_tab     = it_result
    You have defined SELTAB as a SELECT-OPTION.
    So when you pass only SELTAB, the header line is transferred to the FM. When you pass SELTAB[] the whole table(range) is passed.
    It is similar to the concept of an internal table with header line.
    Hope i am clear.
    Anyways how have you defined result_tab and sel_tab ?
    BR,
    Suhas

  • Select Options to RFC function modules

    Hi all
    When we use a PERFORM in main program, we can simply use the select-options
    as for ex.,
    in so_matnr
    in so_bsart
    like that
    without passing any parameters.
    This way it will take all values given in 'Single values' in the multiple selection option of selection screen.
    We need not bother about so_matnr-low and so_matnr-high.
    When we use a function module to be executed in another R/3 server ,
    we have to pass values. In these values we can pass so_matnr-low and so_matnr-high only. If the user selects Single Vals instead of these,
    how to pass them?
    Regards
    Vijaya Chamundi

    Hi,
    so_matnr is stored as a table, with fields sign, option, low and high.
    Each time you add a single value, a line is added to the table.
    If you add 'single value'  1 in the selection screen, then a line is added to table so_matnr[] with fields sign='I', option='EQ' and low='00000..1' and high is empty.
    So, if you want to pass it as a parameter, you can pass it as a table:
    so_matnr[]
    In this way you are sure you have all the information you need.
    regards,
    Rolf

  • How to pass select-option variable in function

    hi ,
    select-option : s_akont for KNB1-akont OBLIGATORY.
    i have to pass s_akont in function without using
    s_akont-low & s_akont-high.
    rightnow i am passing like s_akont but it is giving me a error :
    s_akont is followed by niether by an internal table nor by a value list.
    what should i write.
    regards
    raj

    Hello Raj
    I assume that you want to import your select-options into your function module(s). Since select-options are, by default, itabs with header lines you have to pass your select-options as following:
    CALL FUNCTION 'Z_...'
      TABLES
        it_selopt = s_akont[].
    The TABLES parameter it_selopt could be of type ANY or better of type <b>TABLE</b>.
    If you want to use generic select-option structure you can use <b>RSDSSELOPT</b> and the table type <b>TT_RSDSSELOPT</b>. In this case you would need to copy your select-options from s_akont to a generic type s_generic (of type RSDSSELOPT).
    Regards
      Uwe

  • SELECT OPTIONS IN A FUNCTION

    Hello,
    I need to use a select options in a Function module and then i have to send the values to a Report program.
    How can I do it?
    Thanks.

    This is how I have done in past...
    In a type-group define types like this
    TYPES : zmb52_tr_matnr TYPE RANGE OF mara-matnr ,
            zmb52_tr_werks TYPE RANGE OF marc-werks ,
            zmb52_tr_lgort TYPE RANGE OF mard-lgort ,
            zmb52_tr_charg TYPE RANGE OF mchb-charg ,
            zmb52_tr_mtart TYPE RANGE OF mara-mtart ,
            zmb52_tr_matkl TYPE RANGE OF mara-matkl ,
            zmb52_tr_ekgrp TYPE RANGE OF marc-ekgrp ,
            zmb52_tr_sobkz TYPE RANGE OF mkol-sobkz ,
    and use it in FM like this
    FUNCTION zgetstock.
    *"*"Local Interface:
    *"  IMPORTING
    *"     REFERENCE(I_SPMON) TYPE  SPMON
    *"     VALUE(I_MATNR) TYPE  ZMB52_TR_MATNR OPTIONAL
    *"     VALUE(I_WERKS) TYPE  ZMB52_TR_WERKS OPTIONAL
    *"     VALUE(I_LGORT) TYPE  ZMB52_TR_LGORT OPTIONAL
    *"     VALUE(I_CHARG) TYPE  ZMB52_TR_CHARG OPTIONAL
    *"     VALUE(I_MTART) TYPE  ZMB52_TR_MTART OPTIONAL
    *"     VALUE(I_MATKL) TYPE  ZMB52_TR_MATKL OPTIONAL
    *"     VALUE(I_EKGRP) TYPE  ZMB52_TR_CHARG OPTIONAL

  • How can we pass the select-option value to modulepool program?

    hi,
      how can we pass the select-option value to modulepool program ?
      Because if i declared select-options in executable program and i used SSCRFIELDS to define push buttons in selection screen.
               My requirement if enter the values to select-options and press UPDATE pussbotton then i want call screen which contains tablecontrol.
               How i get select-option values to PAI of call screen for getting the data from database table to my internal table?

    Oh I thought that you have selection-screen and again you are working on dialog programming.
    if you want to use select-option directly in module pool then it is not possible.
    but you can do other way.
    create two varaiables
    data : v_kun_low like kna1-kunnr,
             v_kun_high like kna1-kunnr.
    use these two variables in layout ,let user knows that he can not give options like gt,lt,eq ,it will be always BT.
    and also when you see normal report program,you can use multiple values in either low or high,but here it is not possibel.
    use can enter only low value and high value.
    when you come to program point of view
    declare one range
    ranges r_kunnr for kna1-kunnr.
    do the coding like
    r_kunnr-low = v_kun_low.
    r_kunnr-high = v_kun_high.
    r_kunnr-options = 'BT'.
    r_kunnr-sign = 'I'.
    append r_kunnr.
    now you can use r_kunnr in select query ,it will work like select-option.
    other than this there is no option.
    Thanks
    Seshu

  • How to hide the select-options fields on radiobutton select in webdynpro

    hi
    Could you please help how to hide the select-option fields in webdynpro
    there are four radio buttons
    for every radiobutton there is corresponding the select_option filed is associated to it
    user as only provision select  one radio button and reset of the select-option fileds should be hidden
    which ever the radio button is selected corresponding the select-options fileld should be displayed
    please find the attachement below

    Hi Nine,
    To hide select options you should use interface method REMOVE_SELECTION_SCREEN_ITEM of IF_WD_SELECT_OPTIONS.
    Sample code :
    Write the below code in the Event handler of Radio Button.
    DATA lv_r_helper_class TYPE REF TO if_wd_select_options.
    lv_r_helper_class = lo_interfacecontroller->init_selection_screen(
    lv_r_helper_Class->REMOVE_SELECTION_SCREEN_ITEM(exporting i_id = 'Select_option1_id1').
    This will hide first select option of your screen.Similarly pass select_option_id2 to hide it and so on.
    Regards,
    Ravikiran.k

  • How to pass dynamic selection to logical databse using ldb_process function

    dear friends,
                         can anybode tell me how to pass dynamic selection to the logical database when i m using LDB_PROCESS function module.  however, in EXPRESSIONS paramter of the function module i m  passing the selecti-option, it is passing their also but when i used more than  two select-option or paramter it throw an exception FREE_SELECTIONS_ERROR.
    SO PLEASE GUIDE ME HOW TO PASS MORE THAN TWO SELECT-OPTION IN LOGICAL DATANSE DYNAMICALLY USING LDB_PROCESS.

    would be nice if you post the answer to all

  • In BI how to filter the selection options based on inputs on top field

    Hi Friends,
    In BI, How to filter the selection options based on inputs on top field.
    The system should automatically filter the lower level drop downs based on the selection of a higher level.
    For e.g. :
    If a user selects a Country then the States drop down should only display the State's belongs to the Country. Similarly when a State is selected, the District drop down should display only those District's belongs to the State.
    Thanks in Advance.
    Regards
    Jayaram M

    Hi Anil,
    Thanks for reply but I couldn't use Compounding Characteristic here. Need some other solution.
    Regards
    Jayaram M

  • How can i decleare select-options in module pool table control?

    Hi everybody!!
    Can anyone tell me how can I decleare select-options in module pool table control screen?. I have declared it in a screen with a table control but a dump is triggered due to an error when generating the selection screen.
    Regards...

    My suggestion will be try to use fm
        call function 'FREE_SELECTIONS_DIALOG'
    Please search this forum you can find lot of threads related to this.

  • How to write select options with extension in module pool program

    hi,
    M having  the following fields through screen painter.
    1. sales offfice
    2.sales district
    3.customer no
    for those three fields no extension is not provided and no search help is there.
    i want write  seletion options to get extension in that module pool
    screen.
    plese send coding for me , please let me know how to get that
    select options with the above all three fields.
    Thanks & Regards
    Raji

    Check it
    In top include
    DATA: number(4) TYPE n VALUE '9005',
    PROCESS BEFORE OUTPUT.
      MODULE status_9001.
      CALL SUBSCREEN AREA1 INCLUDING SY-REPID number.
    PROCESS AFTER INPUT.
      MODULE user_command_9001.
      CALL SUBSCREEN AREA1.
    *&      Module  status_9001  OUTPUT
          text
    MODULE status_9001 OUTPUT.
      SELECTION-SCREEN BEGIN OF SCREEN 9005 AS SUBSCREEN.
      PARAMETER pa_bukrs TYPE t001-bukrs.
      select-options matnr for wa_matnr.
      SELECTION-SCREEN END OF SCREEN 9005.
    ENDMODULE.                 " status_9001  OUTPUT

  • How to create the select option in the screen

    HI,
    I am developing one module pool program and I have below requirement,
    currently plant is acting like PARAMETER and the now it should be changed to select option.
    how to create the select option in the screen
    Thanks and regarding,
    Malla
    Moderator message - Please search before asking - post locked
    Edited by: Rob Burbank on Dec 16, 2009 1:41 PM

    Try RANGES.
    The RANGES has same structure as that of select-options.

Maybe you are looking for