How to upgrade Domain - 2003 to 2012 R2 - task sequence

Could someone please sanity check this task sequence?  I need to upgrade a 2003 domain to 2012 R2 and would appreciate a second set of eyes.  thx.
Goal:
1. standup two new 2012 R2 DCs
2. decomm three old DCs
3. raise DFL/FFL to 2012 R2
Current DFL/FFL = 2003 (one site, one domain, 3 DCs, 400 users)
3 Existing DCs (all to be decommed):
  OldDC1 = Svr2003 Std Ed SP2 x64 (holds all FSMO roles, GC=yes)
  OldDC2 = Svr2003 Ent Ed SP1 x86 (holds no FSMO roles, GC=yes)
  OldDC3 = Svr2003 Std Ed SP2 x64 (holds no FSMO roles, GC=no)
New DCs to be added:
  NewDC1 Svr2012 R2
  NewDC2 Svr2012 R2
Proposed task Sequence:
* build and patch OS, then add ADDS role to NewDC1 and NewDC2 (do not yet add servers to existing domain)
* in the network config of new DCs, set the DNS server IP to the IP of OldDC1
* when installing ADDS, I will be prompted to run Adprep.exe - it will be run as part of installing ADDS - this will update existing domain schema as needed.
* add NewDC1 and NewDC2 to existing domain
* in the network config of the new DCs, set the DNS server IP to that of the local server
* make both GCs, make both DNS servers
* distribute FSMO roles thusly:
* DC1 = PDCE, RID (more frequently used roles)
* DC2 = SM, DNM, IM (rarely used roles)
* run dcdiag.exe commands to verify functionality
* power off OldDCs one at a time, waiting 24 hours between each shut down
* raise DFL/FFL to 2012 R2 after all old DCs are decommed

revised and updated
Goal
1. standup two new 2012 R2 DCs
2. decomm three old DCs
3. raise DFL/FFL to 2012 R2
Current DFL/FFL = 2003 (one site, one domain, 3 DCs, 400 users)
3 Existing DCs (all to be decommed):
  OldDC1 = Svr2003 Std Ed SP2 x64 (holds all FSMO roles, GC=yes)
  OldDC2 = Svr2003 Ent Ed SP1 x86 (holds no FSMO roles, GC=yes)
  OldDC3 = Svr2003 Std Ed SP2 x64 (holds no FSMO roles, GC=no)
New DCs to be added:
  NewDC1 Svr2012 R2
  NewDC2 Svr2012 R2
1. Assessment of current AD infrastructure
* http://technet.microsoft.com/en-us/library/hh994618.aspx
http://blogs.technet.com/b/askpfeplat/archive/2012/09/03/introducing-the-first-windows-server-2012-domain-controller.aspx
http://blogs.technet.com/b/askpfeplat/archive/2013/06/03/upgrade-active-directory-to-windows-server-2012-phase-1-assessment.aspx
http://msmvps.com/blogs/mweber/archive/2012/07/30/upgrading-an-active-directory-domain-from-windows-server-2003-or-windows-server-2003-r2-to-windows-server-2012.aspx
2. build and patch OS on NewDCs; in the network config of new DCs, set the DNS server IP to the IP of OldDC1
3. add AD DS role to NewDC1 and NewDC2 (do not yet add servers to existing domain)
* NOTE: when installing AD DS, you will be prompted to run Adprep.exe.  It will be run as part of installing AD DS.  This will update existing domain schema as needed
4. add NewDC1 and NewDC2 to existing domain, promote to domain controllers, add to existing domain at 2003 DFL/FFL.
5. make both DCs GCs, transfer/distribute FSMO roles
* DC1 = PDCE, RID (more frequently used roles)
* DC2 = SM, DNM, IM (rarely used roles)
* http://support.microsoft.com/kb/324801/en-us
6. verify time service on OldDCs are syncing with current DC1 (PDCE)
http://msmvps.com/blogs/mweber/archive/2010/06/27/time-configuration-in-a-windows-domain.aspx
7. run dcdiag.exe commands to verify functionality, address any issues
8. Make new DCs DNS servers
* in the network config of the new DCs, set the DNS server IP to that of the local server
9. retest with dcdiag
10. decomm OldDCs
* reconfigure clients/servers so they no longer point to the OldDCs/DNS
* disconnect network cable from old DCs and test with various clients, reboot clients, retest
* remove GC from old DCs, (also remove DNS role?), then run dcpromo to demote them
* verify that OldDC machine accounts have automatically moved from the DCs OU to Computers container
* check DNS management console in NewDCs, verify all entries from the old DCs are no longer present, delete manually if nec'y
* check AD sites and services and delete the old DCs if nec'y
11. raise DFL/FFL to 2012 R2 after all old DCs are decommed

Similar Messages

  • SCCM 2012 OSD Task Sequence - force Policy and SCEP update?

    Hi,
    How can I force a policy update to update machine policy and scep definitions at the end of
    SCCM 2012 OSD Task Sequence,
    Thanks,
    Ward.

    Hi,
    I normally use this solution from Chris Nackers to deploy the latest EP definitions during OSD and deploy a custom EP policy, it works great. The policy will be downloaded when the client is registered.
    Regards,
    Jörgen
    -- My System Center blog ccmexec.com -- Twitter
    @ccmexec

  • Upgrade from 2003 to 2012

    when migrate from 2003 to 2012 server all user and ou in activedirectiry  go to server 2012 or not
    can upgrade from 2003  to 2008 to 2012 or not

    Yes, you can add a 2012 server as a domain controller in your 2003 R2 functional level Active Directory.  All AD information will replicate to the 2012 DC.
    http://blogs.technet.com/b/canitpro/archive/2013/05/27/step-by-step-active-directory-migration-from-windows-server-2003-to-windows-server-2012.aspx
    . : | : . : | : . tim

  • SCCM 2012 R2 Task Sequence to Restart Computers

    This is a simple question but I cannot seem to get it right.
    I am working on Monthly Maintenance plan for my servers and I cannot seem to get it right, any help would greatly appreciate it.
    I have Server collections for all OS's (2003, 2008...2012 R2) with maintenance windows for all deployments daily 8PM to 5am.
    I have ADRs setup to run and evaluate the last Thursday of the month to install updates on my machines.
    I have 4 collections created for Server Reboot 1st, 2nd, 3rd, and 4th with Maintenance Window Monthly for the last Friday/Saturday 8PM - 5AM for Task Sequences Only
    I created a Task Sequence called Server Reboot by doing the following:
    Create Task Sequence>Custom Task Sequence>Add x86 Boot Image file
    In the TS I click Add>General>Restart Computer, Add message "Computer will restart............"
    When the Task Sequence runs it does not display the message nor does it reboot the computer, what am I doing wrong?
    Basically I want to install updates on the Last Thursday of the month to my servers, Last Friday of the Month through Saturday morning I want to restart the servers to finish applying the updates, etc.
    What is the best way to accomplish this? Thanks for any suggestions or help!

    I concur with Torsten and narcoticoo -- using a simple package is better.
    One thing you noted however is the use of multiple maintenance windows. Maintenance Windows are not in any way specific to just the deployments on the collection where the MW is applied. MWs are applied to the clients in the collection and the client enforces
    them on *all* deployments it is assigned. Collections are strictly used by the site to build policies -- which include deployments and MWs among other things but not any collection information. Those policies are then delivered to the clients who enforce them
    without regard to collections at all.
    Jason | http://blog.configmgrftw.com

  • MDT 2012 Suspend Task Sequence Problem

    Hi ,
    I have been using LTISuspens.wsf without problem in my MDT 2010 and MDT 2010 U1 for a long time. Recently I have create my test MDT 2012 and I have problem with this task.
    I have created the new Run Command line cscript.exe "%SCRIPTROOT%\LTISuspend.wsf" in State Restore section. The build and capture TS is stopping correctly and I have the LTISuspend icon on the desktop. After resuming the TS, it going correctly through, running
    sysprep, pop in again Set Network Location window, I can see it is running “Apply Windows PE (BCD)” step and then stops. There is message “suspended” and “The task sequence has been suspended true Use the…..”
    Any ideas what I am doing wrong?
    My customsettings.ini is from MDT 2010 and there they are fine.
    I am capturing Windows 7.
    Thanks
    Vinnie

    Hi,
    A few suggestions below for each of your issues.
    Issue 1 is that you don't see any task sequences in the wizard
     - Have you updated your deployment point after upgrading to 2012? if not then do this now
     - Have you updated your boot media with the newly generated Litetouch_x86.wim (meaning your boot CD, boot USB or WDS)
    The thinking behind this is that if you are using MDT 2010 boot media to try and speak to an MDT 2012 DS then you will have the same problem.
    Issue 2 is that you've had the TS running in the past but it's broken for one reason or another.
     - Have you recreated your Task sequence using the MDT 2012 client template? There are (minor but critical) differences in the logic between the versions of MDT and the new task sequence template has been updated as such. Using an MDT 2010 template with
    MDT 2012 scripts can cause this.
    These are 3 things that cause similar issues to you following an upgrade.

  • Create a prompt using MDT 2012 in SCCM 2012 OSD task sequence

    Hi Experts,
    I need some help with SCCM 2012 Task sequence using MDT 2012.
    Here is the scenario:I want to build a task sequence  where it will propmt whether the technican want to build a new build or refresh. Based on the technicians choice the task sequence will perform specific actions.
    We can create the prompt using HTA or VBScript or some otherways.
    But the requiremnt for us is to Use ONLY MDT 2012, not any other ways.
    Is it possible to do like the above with UDI?
    Please can someone shed some light how to do will be great.
    Thanks in advance,

    Hi,
    UDI may achieve what you want. Take a look at the blogs below.
    http://blogs.technet.com/b/anilm/archive/2012/06/01/integrating-mdt-2012-rtm-with-configuration-manager-2012-rtm-part-3-creating-and-deploying-a-udi-task-sequence.aspx
    http://heinrichandsccm.blogspot.com/2013/04/how-to-setup-and-configure-sccm-2012.html
    Important Note: Microsoft provides third-party contact information to help you find technical support. This contact information may change without notice. Microsoft does not guarantee the accuracy of this third-party contact information.
    Juke Chou
    TechNet Community Support

  • Prestage computer name for known/unknown computers in sccm 2012 R2 task sequence

    How can we prestage computer name in SCCM 2012 Task Sequence?

    Can you be a little more specific about what it is you're trying to do?  Are you looking to create/import the computer record ahead of time and have it utilize that name during OS deployment?

  • Leave Data Drive (D:) Untouched During Rebuild In ConfigMgr 2012 SP1 Task Sequence

    Windows Server 2008 R2, ConfigMgr 2012 SP1
    I'm looking for a way to put logic on a Task Sequence that will only format/wipe the OS partition during a rebuild i.e. leave the Data Partition (D: drive) untouched.
    I have removed "Format And Partition Disk" task then which
    option should be selected in "Apply operating system images" task.
    SourabhR

    Thanks Peter, Its worked for me :)
    After proceeding with this approach got another block.
    how could i avoid such cases as shown below where another partition is available before the boot partition. According to
    Next available formatted partition option,highlighted partition will be wiped and will get the OS.
    Is there any way like preflight checks (TS variable or wmi queries,conditions),so i can avoid this type of scenarios.
    SourabhR

  • SCCM 2012 OSD Task Sequence Fails "An error occurred while retrieving policy for this computer"

    We have SCCM 2012 R2. I amm trying to start OSD task sequence from bootable media.
    Hyper-v client gets DHCP ip and starts MDT bootable media, but could not find policy.
    From F8 I can ping SCCM/DP/MP server.
    What could be the cause?

    Yes, this DHCP client is in the same subnet as other working clients.
    smsts.log from client
    Request was successful. TSPxe
    21.03.2014 14:14:14 324 (0x0144)
    pNext != NULL, HRESULT=80004005 (e:\nts_sccm_release\sms\framework\osdmessaging\libsmsmessaging.cpp,1970)
    TSPxe 21.03.2014 14:14:14
    324 (0x0144)
    reply has no message header marker TSPxe
    21.03.2014 14:14:14 324 (0x0144)
    DoRequest (sReply, true), HRESULT=80004005 (e:\nts_sccm_release\sms\framework\osdmessaging\libsmsmessaging.cpp,5868)
    TSPxe 21.03.2014 14:14:14
    324 (0x0144)
    Failed to get client identity (80004005)
    TSPxe 21.03.2014 14:14:14
    324 (0x0144)
    ClientIdentity.RequestClientIdentity (), HRESULT=80004005 (e:\nts_sccm_release\sms\client\tasksequence\tsmbootstrap\tsmediawizardcontrol.cpp,1113)
    TSPxe 21.03.2014 14:14:14
    324 (0x0144)
    failed to request for client
    TSPxe 21.03.2014 14:14:14
    324 (0x0144)
    Exiting TSMediaWizardControl::GetPolicy. TSPxe
    21.03.2014 14:14:14 324 (0x0144)

  • SCCM 2012 - OSD Task Sequence Error 0x80091007

    When deploying the OSD to a laptop model the TS is failing, see below from Status Message Viewer:
    The task sequence execution engine failed executing the action (Apply E6220 Driver Package) in the group (PostInstall) with the error code 2148077575
    Action output: urce, sSourceDirectory, dwFlags, hUserToken, pszUserName, pszUserPassword), HRESULT=80091007 (e:\nts_sccm_release\sms\framework\tscore\resolvesource.cpp,3217)
    ResolveSource(pszSource, sSourceDirectory, dwFlags, 0, 0, 0), HRESULT=80091007 (e:\nts_sccm_release\sms\framework\tscore\resolvesource.cpp,3122)
    TS::Utility::ResolveSource( pszPackageId, sSource ), HRESULT=80091007 (e:\nts_sccm_release\sms\client\osdeployment\osddriverclient\driverinstaller.cpp,472)
    pDriverInstaller->InstallDriverPackage( sPackageId, pBootCriticalInfo ), HRESULT=80091007 (e:\nts_sccm_release\sms\client\osdeployment\osddriverclient\osddriverclient.cpp,380)
    Exiting with return code 0x80091007
    Hash could not be matched for the downloded content. Original ContentHash = EB2A940227C7043DDDCE0985EB37CBB650245F47F12ACD48C936521F5CECAFED, Downloaded ContentHash = 6F4ED0BD9ECC46712E6160BF681ED3785097D95A43652424FB97E12EB1EAF8E3
    Failed to determine the driver source location. Code 0x80091007
    Failed to provision driver. Code 0x80091007. The operating system reported error 2148077575: The hash value is not correct. 
    I have redistributed the Driver packages to the DP's but still no luck - does anyone have any idea's?
    Thanks
    MCTS | MCITP | MCSA

    Below is the whole thread from Expert-sex-change.com: 
    SCCM OS deployment error (0x80091007)
    Asked by: MoritzCSA
    We are getting Error on one of your Primary Child site when deploying a XP Install Package.
    In the Advertisment Status we are getting following errors:
    The task sequence execution engine failed executing the action
    (Apply Operating System Image) in the group () with the error code
    2148077575
    Action output: zSource, sSourceDirectory, dwFlags, hUserToken,
    pszUserName, pszUserPassword), HRESULT=80091007
    (e:\nts_sms_fre\sms\framework\tscore\resolvesource.cpp,3130)
    ResolveSource(pszSource, sSourceDirectory, dwFlags, 0, 0, 0),
    HRESULT=80091007
    (e:\nts_sms_fre\sms\framework\tscore\resolvesource.cpp,3031)
    TS::Utility::ResolveSource( this->packageID, this->packagePath,
    TS::Utility::ResolveSourceFlags::PersistContents ),
    HRESULT=80091007
    (e:\nts_sms_fre\sms\client\osdeployment\applyos\installscripted.cpp,
    160)
    installer.install(), HRESULT=80091007
    (e:\nts_sms_fre\sms\client\osdeployment\applyos\installscripted.cpp,
    632)
    Entering ReleaseSource() for
    C:\_SMSTaskSequence\Packages\GID00004
    The user tries to
    release a source directory
    C:\_SMSTaskSequence\Packages\GID00004 that is either already
    released or we have not connected to it InstallScripted(
    g_InstallPackageID, g_ImageIndex, targetVolume,
    g_ConfigPackageID, g_ConfigFileName ), HRESULT=80091007
    (e:\nts_sms_fre\sms\client\osdeployment\applyos\applyos.cpp,397).
    The operating system reported error 2148077575: The hash value is
    not correct.
    The task sequence execution engine aborted execution for a failure
    of the action (Apply Operating System Image) in the group (). The
    operating system reported error 2148077575: The hash value is not
    correct.
    The task sequence execution engine failed execution of a task
    sequence. The operating system reported error 2148077575: The
    hash value is not correct.
    The task sequence manager could not successfully complete
    execution of the task sequence. A failure exit code of 16389 was
    returned.
    appreciate any help
    IMAG0020.jpg
    747 KBscreenshot off error on Client Computer when deploying OS
    2010-02-05 at 04:39:43ID: 25117354TopicsMS System Center ,Deployment Software for DevelopmentParticipating Experts3Points0Comments9
    Request Attention
    Answers
    EXPERT COMMENT
    by: NJComputerNetworksPosted on 2010-02-05 at 05:29:05ID: 26494779
    1) enable f8 boot console on your boot image:  http://www.windows-noob.com/forums/index.php?/topic/546-how-can-i-troubleshoot-windows-pe-booting-in-sccm/  this will get you to a command prompt on the client
    2) look at the smsts.log for exactly why your client is failing osd:  http://blogs.technet.com/inside_osd/archive/2007/12/13/troubleshooting-tips.aspx
    3) also look at the reports for information as to why your OSD is failing:  http://blogs.technet.com/inside_osd/archive/2007/12/13/troubleshooting-tips.aspx
    AUTHOR COMMENT
    by: MoritzCSAPosted on 2010-02-05 at 05:39:33ID: 26494871
    Hi,
    Its not the Boot image what has problems. Its one single OS package as others workjust fine
    EXPERT COMMENT
    by: NJComputerNetworksPosted on 2010-02-05 at 06:01:11ID: 26495086
    lol... ok... but enabling F8 will allow you to get to the smsts.log which should contain some more information about why the single OS package is failing.
    EXPERT COMMENT
    by: JonLambertPosted on 2010-02-08 at 01:43:35ID: 26512090
    OK, it looks like (as descripted in the logs) that the Hash Value for the package GID00004 is not correct.
    I've seen this before with Boot WIMS, if GID00004 is a boot WIM package, then try creating a new Boot Wim, deploying it to the relevant DPs, assigning it to th TS and try again.
    If GID00004 is not a Boot WIM, then try updating the package, and keep an eye on DistMgr.log to ensure it get's distributed Ok.
    AUTHOR COMMENT
    by: MoritzCSAPosted on 2010-02-09 at 07:13:55ID: 26524885
    Hi have recreated the OS Install Packlage and have distributed it again to the Primary Child site. Still the same issue as for example the same OS in English is running fine. GID00004 was an OS Install Package.
    I have the log file from the F8 boot atached
    smsts-20100210-001651.log
    976 KBlog
    smsts.log
    391 KBlog2
    ADMINISTRATIVE COMMENT
    by: TheLearnedOnePosted on 2010-03-03 at 18:54:29ID: 27299334
    MoritzCSA,
    After 21 days without comment, it is time for you to finalize this old question -- accept an answer, split points, or get a refund.  Please be a responsible EE Member and maintain your open questions! Click here to see your options: http://www.experts-exchange.com/help.jsp#hi331
    EXPERTS,
    I need your help.  Please post your closing recommendations within a few days.  If you do not respond, I may need to assume that no correct answer was provided.
    TheLearnedOne
    Experts-Exchange Cleanup Volunteer
    EXPERT COMMENT
    by: JonLambertPosted on 2010-03-03 at 19:17:39ID: 27299526
    OK, now the package with an hash error is GID0002A .. which is the OS Install Package, Check the source directory for files with odd characters, or extremely long directory paths .. this can sometime cause a hash-check mismatch.
    Hash could not be matched for the downloded content. Original ContentHash = A9173DC49D149170C0F7F5526154AC4381ED0DC0, Downloaded ContentHash = 88601C0BA124401EA13790D2F318AF04CB283DD1      ApplyOperatingSystem     
    9/02/2010 3:29:21 PM      1680 (0x0690)
    ACCEPTED SOLUTION
    by: MoritzCSAPosted on 2010-03-04 at 00:23:07ID: 27300766
    I have change the OS installation to not download the package. After this change it works fine without issues.
    0
    excellent
    Save to Personal Knowledgebase
    EXPERT COMMENT
    by: DSS-RMPosted on 2010-10-17 at 07:14:56ID: 33923836
    Update the distribution points of the package that was failing. I have had this same problem and a distribution point update will fix it.

  • T540p - Thinkpad Pro Dock - 90w model 40A1009xx - SCCM 2012 r2 Task Sequence

    My company receently purchased 40 Lenovo T540p and 40 Pro Docks
    We are using SCCM 2012 r2.
    I downloaded the sccm driver package for the Lenovo T540p.
    Imaged the laptop and all seemed okay until I connected it to the docking station.
    First off it would not recongize anything connected to the usb's so I reinstalled the usb 3.0 driver.
    When I did that it did recongize usb deviced, but now the dock shows up as an unrecongized device.
    Also if I undock the laptop and redock it I have to reboot the laptop for it to recongize what is connected to the usbs in the back.
    Note there are no video problems.

    We do not create SCCM driver packs for the Edge line of products.  As an alternative you can use Update Retriever to download hardware drivers for a selected model and then use the Export feature to create a folder containing the source files for the drivers.  This can then be used in the Driver Import Wizard which will locate the INF files and only import the files referenced by the INF files.
    You mention you are using SCCM 2012 R2.  This means you should be using the Windows ADK for 8.1 which also means your boot images should be using Windows PE 5.  For your boot images you should be using the Windows 8.1 driver (http://download.lenovo.com/ibmdl/pub/pc/pccbbs/mobiles/herr01ww.exe)
    In your OSD task sequence you need to be deploying Windows 7 drivers (http://download.lenovo.com/ibmdl/pub/pc/pccbbs/mobiles/her101ww.exe)
    Make sure you keep these separate.  Meaning you should have a driver package for the Windows 7 drivers that you reference in an Apply Drivers task and this package should not include the Windows 8.1 drivers.  Add just the 8.1 drivers to the boot image.

  • SCCM 2012: install task sequence to VHD WITHOUT hyper-v being installed?

    Hi,
    I'd like to install an OS to a VHD(X) without the need of installing hyper-v on the sccm-server, can that be done?
    Not out of the box probably, but I could copy the current task sequence and give an option to choose the installation disk.
    That way I could boot on a workstation into winpe, create a vhd, reboot to PXE, choose the specific tasksequence and choose the vhd to install to.
    Can it be done and if so how (how to change the ts in order to be able to choose the vhd to install to?).
    Please advise.
    J.
    Jan Hoedt

    Great! Next thing would be to deploy to vhdx then deploy vhdx to pc via ts. The ts would then wipe the disk, make bootpartition and add vdisk via bcdboot. This would give a lot of flexibility in terms of deployment speed (only 1 file to deploy, not that
    many reboots)backup (mount vhd to recover data),adding extra os, running clients vhd on hyperv host ... Only issue would be how to add machine specific drivers. Probably this topic has been discussed already. What s your point of view on this?
    Jan Hoedt

  • How to upgrade Domain Controller 2008 to 2012 on New Server

    Hi All,
    We are planning to upgrade our domain controller and exchange server 2008 to 2012 R2, so can anyone please suggest what step should be taken first. we have new server machine we are planning to install Windows 2012 R2 and create a additional domain controller
    of our existing domain 2008 then transfer the FSMO roles to this server to act as a primary. after successful migration we will upgrade our exchange 2008 to 2012. please advice is there any problem to do this way.
    Thanks
    Agha

    I was just curious about the same thing. However, I am running 32bit version of server 2008 and want to move the server 2012 r2. This will be on a machine with new hardware and all. Am just curious though if it is possible to migrate some of the
    domain as to not to have to replicate everything?
    Directory Services doesn't really care what version of the OS you are using.  You cannot do an in-place upgrade from a 32bit box to a 64bit box.
    You'll need to make your new R2 server, install AD, move the FSMOs, and demote your 2008 32bit box.
    What WOULDN'T you want to replicate?  That's not how AD works.  It's a multimaster enviroment where ALL DCs have the same information.  You can't choose which objects replicate.  To do that, you'll need to clean up your AD.
    Good luck.
    - Chris Ream -
    **Remember, if you find a post that is helpful, or is the answer, please mark it appropriately.**

  • Any suggestion on where to buy and how to Upgrade MBP 15" (2011-2012) myself?

    Hi, after my other post has been answered (thanks again!).
    Now I'm looking for suggestions on:
    - where to buy RAM, CPU, Video Card, HDD (cheap but good )
    - and how to do this Upgrade myself
    Fro my (future ) MBP 15" Late-2011 or Mid-2012 models.
    Thanks in advance.

    kvnMac,
    you can buy compatible RAM and HDDs for those MacBook Pro models from many reputable vendors, as well as from online auction sites (if you know exactly what you’re after — caveat emptor). Upgrading either the RAM or the HDD is fairly straightforward; the only unusual tool that you’d need for the HDD is a T6 Torx screwdriver.
    As far as upgrading the CPU or the graphics card on a MacBook Pro, that’s a different matter — neither is easily removed nor easily replaced, and I don’t know where one would go shopping for suitable CPUs or GPUs.

  • How to Apply Windows 8´s themepack during Task Sequence

    I was trying to find any info, how to apply themepack with TS, during Windows 8.1 deployment, but there is no info I could find.
    I´m aming to customize fully the look of Windows 8.1, I aleady have different layout profiles pushing to tablets and PCs, but I also want to fully redo and deploy my own theme. I have W8.deskthemepack file saved (480 kb size), but how I could apply
    it with run command line as default theme? It must also cantain the lock screen.
    I know about desk.cpl but I have no idea how to add switches around it.

    Hi,
    I found a relevant blog for your reference.
    Windows 8 Deploy – Apply Theme
    http://www.bewi.at/?p=803
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.
    Thanks for help, I will try this and report the result! Thanks, I will mark your post as an answer later.

Maybe you are looking for

  • I want to implement thems functionality in  my swing application

    Hi All... I want to implement the themes object in my swing application,How ,where to start and move that functionality,If anybody use this functionality in your program experience can u share with me. Than to Advance ARjun...

  • How to print an adobe form with xml interface in r3

    I have a Web dynpro application that creates an ADOBE form using an XML schema interface. I need to be able to print the same form in R/3 - is this possible? If so how do I create the interface? Thanks

  • SAP Course for beginner in London

    Hi, I am in Shipping & Logistics business and want to change into SAP. Although I have over 9 years experience in the business I have been told that I need to support it with certificate in MM, LE or SRM. I tried to find a course over the internet an

  • Iweb adding extra characters - encoding as Latin-1 instead of UTF-8?

    mines.edu/academic/met/jip/ Can't get the extra characters off this page. When you view source, it shows extra characters in. When page encoding is changed to UTF-8, works just fine. However, the school webmasters say it is not a problem on server si

  • Erazer doesn't recognize Nvidia Geforce 650 card

    In brief, after a series of failed attmepts to repair my H530 desktop, Lenovo replaced it with an Erazer x510, since the H530 was no longer in production. When the Erazer arrived, I was unable to get a video signal. I tried my HDMI and VGA cables. I