How to use CS4 to control my photo scanner?

How do I use CS4 to scan slides or pics using my new Epson photo scanner?

File>Import
You should see a TWAIN, WIA or Epson option to the right.
If that option isn't there, look into the software for your scanner. CS4 still used (or at least had available) TWAIN scanning capabilities, but in the 32 bit version only. You may need the TWAIN plugin for CS4. http://helpx.adobe.com/photoshop/kb/twain-plug-photoshop-cs4-cs5.html

Similar Messages

  • How to Use CS4 using C#

    Hello guys am new to adobe forum. please help me. am in trouble!!!
    i  have got one project regarding IN DESIGN. am .net developer, i have downloaded CS4 server free trail.
    can any one please tell me how to use CS4 using c# ? urgent please.

    (Disclaimer: I have no personal experience with C# and IDS. My 
    comments are based on what I've seen from comments of others on the 
    scripting forum...)
    Very painfully!
    In InDesign there's a lot of pitfalls using C# being its a very 
    strongly typed language, and not really supported.
    I strongly suggest you try to do it  in VBS or JS instead.
    You can pass VBS or JS to the doScript method from C#. Search the 
    scripting forum for further clues.
    In Server, it's less painful, but unless absolutely necessary, you 
    might want to carefully consider your choice of language...
    Here's some docs (taken from my archives of the scripting forum):
    http://www.adobe.com/devnet/indesign/sdk/InDesign_CS3_Server_SDK_Readme.txt
      (I don't have a link handy to the CS4 version.)
    http://www.codeproject.com/KB/COM/Adobe_s_Indesign_COM_obje.aspx
    http://p2p.wrox.com/net-framework-1-x/62966-implementing-indesign-files-asp-net.html
    Also, download the SDK. There's details in the guides on how to 
    control IDS with SOAP using C# among other languages.
    Harbs

  • How to use the print option for photos?

    How to use the print option for photos.  I have a wireless printer but how do I set it up?

    http://www.apple.com/support/iphone/assistant/airprint/

  • [Forum FAQ] How to use parameter to control the Expand/Collapse drill-down options in SSRS report?

    In SQL Server Reporting Services (SSRS), drill-down is an action we can apply to any report item to hide and show other report items. They all are ways that we can organize and display data to help our users understand our report better. In this article,
    we are talking about how to use parameter to control the Expand/Collapse drill-down options in SSRS report.
    Consider that the report has a dataset (dsSales) with following fields: SalesTerritoryGroup, SalesTerritoryCountry, CalendarYear, SalesAmount.
    1. The report has the following group settings:
    Parent Group: SalesTerritoryGroup
     Child Group: SalesTerritoryCountry
      Child Group: CalendarYear
       Details: SalesAmount
    2. Add three parameters in the report:
    GroupExpand:
    Available Values: “Specify values”
    Label: Yes           Value: Yes
    Label: No            Value: No
    Default Values: “Specify values”
    Value: Yes
    CountryExpand:
    Available Values: “Specify values”
    Label: Yes           Value: =IIF(Parameters!GroupExpand.Value="No",Nothing,"Yes")
    Label: No            Value: No
    Default Values: “Specify values”
    Value: =IIF(Parameters!GroupExpand.Value="No","No","Yes")
    YearExpand:
    Available Values: “Specify values”
    Label: Yes          
    Value: =IIF(Parameters!GroupExpand.Value="No" or Parameters!CountryExpand.Value="No",Nothing,"Yes")
    Label: No            Value: No
    Default Values: “Specify values”
    Value: =IIF(Parameters!GroupExpand.Value="No" or Parameters!CountryExpand.Value="No","No","Yes")
    3. Right click SalesTerritoryCountry icon in the Row Groups dialog box, select Group Properties.
    4. Click Visibility in the left pane. Select “Show or hide based on an expression” and type with following expression:
    =IIF(Parameters!GroupExpand.Value="Yes", False, True)
    Select “Display can be toggled by this report item” option, and select “SalesTerritoryGroup” in the drop down list.
    5. Use the same method setting CalendarYear, (Details) drill-down with following expression:
    =IIF(Parameters!CountryExpand.Value="Yes", False, True)
    =IIF(Parameters!YearExpand.Value="Yes", False, True)
    6. Click SalesTerritoryGroup text box in the tablix. Select InitialToggleState property in the Properties dialog box, and type following expression:
    =IIF(Parameters!GroupExpand.Value="Yes", True, False)
    7. Use the same method setting SalesTerritoryCountry, CalendarYear text box with following expression:
    =IIF(Parameters!CountryExpand.Value="Yes", True, False)
    =IIF(Parameters!YearExpand.Value="Yes", True, False)
    After that, when we preview the report, we can use these three parameters to expand/collapse drill-down.
    Note:
    In our test, we may meet following issue. We can check the expression of InitialToggleState property to troubleshooting the issue.
    Applies to
    Reporting Services 2008
    Reporting Services 2008 R2
    Reporting Services 2012

    In SQL Server Reporting Services (SSRS), drill-down is an action we can apply to any report item to hide and show other report items. They all are ways that we can organize and display data to help our users understand our report better. In this article,
    we are talking about how to use parameter to control the Expand/Collapse drill-down options in SSRS report.
    Consider that the report has a dataset (dsSales) with following fields: SalesTerritoryGroup, SalesTerritoryCountry, CalendarYear, SalesAmount.
    1. The report has the following group settings:
    Parent Group: SalesTerritoryGroup
     Child Group: SalesTerritoryCountry
      Child Group: CalendarYear
       Details: SalesAmount
    2. Add three parameters in the report:
    GroupExpand:
    Available Values: “Specify values”
    Label: Yes           Value: Yes
    Label: No            Value: No
    Default Values: “Specify values”
    Value: Yes
    CountryExpand:
    Available Values: “Specify values”
    Label: Yes           Value: =IIF(Parameters!GroupExpand.Value="No",Nothing,"Yes")
    Label: No            Value: No
    Default Values: “Specify values”
    Value: =IIF(Parameters!GroupExpand.Value="No","No","Yes")
    YearExpand:
    Available Values: “Specify values”
    Label: Yes          
    Value: =IIF(Parameters!GroupExpand.Value="No" or Parameters!CountryExpand.Value="No",Nothing,"Yes")
    Label: No            Value: No
    Default Values: “Specify values”
    Value: =IIF(Parameters!GroupExpand.Value="No" or Parameters!CountryExpand.Value="No","No","Yes")
    3. Right click SalesTerritoryCountry icon in the Row Groups dialog box, select Group Properties.
    4. Click Visibility in the left pane. Select “Show or hide based on an expression” and type with following expression:
    =IIF(Parameters!GroupExpand.Value="Yes", False, True)
    Select “Display can be toggled by this report item” option, and select “SalesTerritoryGroup” in the drop down list.
    5. Use the same method setting CalendarYear, (Details) drill-down with following expression:
    =IIF(Parameters!CountryExpand.Value="Yes", False, True)
    =IIF(Parameters!YearExpand.Value="Yes", False, True)
    6. Click SalesTerritoryGroup text box in the tablix. Select InitialToggleState property in the Properties dialog box, and type following expression:
    =IIF(Parameters!GroupExpand.Value="Yes", True, False)
    7. Use the same method setting SalesTerritoryCountry, CalendarYear text box with following expression:
    =IIF(Parameters!CountryExpand.Value="Yes", True, False)
    =IIF(Parameters!YearExpand.Value="Yes", True, False)
    After that, when we preview the report, we can use these three parameters to expand/collapse drill-down.
    Note:
    In our test, we may meet following issue. We can check the expression of InitialToggleState property to troubleshooting the issue.
    Applies to
    Reporting Services 2008
    Reporting Services 2008 R2
    Reporting Services 2012

  • I need to program a Hittite Fractional​-N Synthesize​r Evaluation Kit with a HMC702LP6C​E an external YIG oscillator​. Not sure how to use Labview to control the PLL.

    I need to program a Hittite Fractional-N Synthesizer Evaluation Kit with a HMC702LP6CE an external YIG oscillator.  Not sure how to use Labview to control the PLL.

    Here is how to use the PLL. But I don't know of how to interact with that device
    http://zone.ni.com/devzone/cda/tut/p/id/3781
    And for thouse who don't know what a PLL is a free bonus link is here:
    http://digital.ni.com/public.nsf/allkb/07BC8D77D4E​9AE258625708B007CE74F?OpenDocument
    and a second one on what that device is: http://www.hittite.com/products/view.html/view/HMC​702LP6CE
    Now we are all caught up to speed.
    Sam S
    Applications Engineer
    National Instruments

  • How to use tcom to control vi

    how we use tcom to control vi program? we have got this tcl script from googling  but it is not running , it says to run the vi as activex server ,how can we do it? it is opening the vi but gives the error "high frequency not found in vi connector pane.what are the different methods that we can use with vi ? in the example  some methods such as  getvireference  etc have been used
    # Interfacing to LabView via TCOM
    package require tcom
    # Start the "Frequency Response" VI as an ActiveX server.  (If the VI
    #was
    # compiled then you would refer to it by its registered server name.
    #For
    # example, if you compiled 'A.vi' and created 'A.exe', then you would
    #load
    # it with 'set lv [::tcom::ref createobject "A.Application"]'.)
    set lv [::tcom::ref createobject "LabView.Application"]
    # Create a reference to the VI.  (You may want to use
    # '[$lv ApplicationDirectory]' to get the correct path for this PC.
    # For a compiled VI, use just the VI's name, for example:
    # 'set viPath "A.vi"'.)
    set viPath "C:\\Program Files\\National Instruments\\LabVIEW 8.2\\examples\\apps\\freqresp.llb\\Frequency Response.vi"
    set vi [$lv GetVIReference $viPath]
    $vi FPWinOpen True
    # Create the parameter arrays.  The first array is a list of terminal
    #names;
    # the second array is a list of their values.  We must pass in a value
    #for
    # every terminal on the VI's connector (unless we are very sure that
    #the VI
    # has a valid initial value for that terminal).  We must also pass in
    #a
    # value for the output terminals; LabView will ignore it.
    set names [list Amplitude "Number of Steps" "Low Frequency" "High
    Frequency" "Response Graph"]
    # Create the values array
    set values [list 5 105 15 1005 0]
    # Call the VI and get the results
    $vi Call names values
    # The Response Graph is returned in 'values'
    puts $values
    #5 105 15 1005 {{400.0 406.238291234 412.573873162...
    # If the VI is running we cannot use the 'Call' method, but we can
    # set and query individual Controls/Indicators.  (The "Frequency
    # Response" VI does not continue running - you call it, it runs, then
    # it stops until you call it again.  However, many VIs run
    #continuously
    # once you start them, and many are set to start running as soon as
    #you
    # load them.  Obviously, compiled VIs typically start running as soon
    # as you load them.)
    $vi SetControlValue "Low Frequency" 5
    $vi SetControlValue "Amplitude" 10
    $vi GetControlValue "Amplitude"
    # 10
    # The graph hasn't changed (because the VI isn't running), but we can
    # still read it.  Notice that the graph is an Indicator (not a
    #Control),
    # but we still use the 'GetControlValue' method to read it.
    set new_graph [$vi GetControlValue "Response Graph"]
    # You may need to manipulate the VI's menus.  Unfortunately LabView
    #does
    # not expose any method for doing this, so you must use the Windows
    # Scripting Shell.  The <ESC> key does not seem to work this way, so
    # the menus should have shortcuts that use ALT or Ctrl key
    #combinations.
    # Start the Windows Scripting Shell and send an <ALT> key to the GUI
    set WShell [::tcom::ref createobject WScript.Shell]
    $WShell SendKeys %%
    $WShell SendKeys {DOWN}
    # Send Alt-X
    $WShell SendKeys %X
    # When we are done, we may want to shut down the VI.
    $lv Quit

    Hi,
    I'm not too familiar with tcom interfacing with LabVIEW, but you may want to check out other DFs, such as this one here.  Would it be possible to printscreen the LabVIEW error you are talking about- "high freq not found...".  Furthermore, you may want to confirm the functionality of the script with the person who made it.
    I hope this helps,
    Regards,
    Nadim
    Applications Engineering
    National Instruments

  • How to use the custom control ?

    Hi Friends,
    plz help to use of  custom control in screen painter ?
    and how to use the custom control ?
    Thanking you.
    Regards,
    Subash.

    HI,
    Screen Elements
    A screen can contain a wide variety of elements, either for displaying field contents, or for allowing the user to interact with the program (for example, filling out input fields or choosing pushbutton functions). You use the Screen Painter to arrange elements on the screen.
    You can use the following elements:
    ·        Text fields
    Display elements, which cannot be changed either by the user or by the ABAP program.
    ·        Input/output fields and templates
    Used to display data from the ABAP program or for entering data on the screen. Linked to screen fields.
    ·        Dropdown list boxes
    Special input/output fields that allow users to choose one entry from a fixed list of possible entries.
    ·        Checkbox elements
    Special input/output fields that the user can either select (value ‘X’) or deselect (value SPACE). Checkbox elements can be linked with function codes.
    ·        Radio button elements
    Special input/output fields that are combined into groups. Within a radio button group, only a single button can be selected at any one time. When the user selects one button, all of the others are automatically deselected. Radio button elements can be linked with function codes.
    ·        Pushbuttons
    Elements on the screen that trigger the PAI event of the screen flow logic when chosen by the user. There is a function code attached to each pushbutton, which is passed to the ABAP program when it is chosen.
    ·        Frame
    Pure display elements that group together elements on the screen, such as radio button groups.
    ·        Subscreens
    Area on the screen in which you can place another screen.
    ·        Table controls
    Tabular input/output fields.
    ·        Tabstrip controls
    Areas on the screen in which you can switch between various pages.
    ·        Custom Controls
    Areas on the screen in which you can display controls. Controls are software components of the presentation server.
    ·        Status icons
    Display elements, indicating the status of the application program.
    ·        OK field
    Every screen has a twenty-character OK_CODE field (also known as the function code field) that is not displayed directly on the screen. User actions that trigger the PAI event also place the corresponding function code into this field, from where it is passed to the ABAP program. You can also use the command field in the standard toolbar to enter the OK field. To be able to use the OK field, you need to assign a name to it.
    All screen elements have a set of attributes, some of which are set automatically, others of which have to be specified in the Screen Painter. They determine things such as the layout of the screen elements on the screen. You can set the attributes of screen elements in the Screen Painter - either for a single element, or using the element list, which lists all of the elements belonging to the current screen. Some of the attributes that you set statically in the Screen Painter can be overwritten dynamically in the ABAP program.
    with regards,
    sowjanyagosala

  • HT1338 I have OS X.9 and I cannot use my Epson Perfection 4490 Photo Scanner. There is no driver available on the Epson site. What can I do?

    I have OS X.9 and I cannot use my Epson Perfection 4490 Photo Scanner. There is no driver available on the Epson site. What can I do?

    Did you try the driver from this Epson page: Epson Perfection 4490 Photo, Drivers & Downloads - Technical Support - Epson America, Inc.
    OT

  • How to use ikons rather then actual photos on e-mails?

    How do I use ikons instead of actual photos (jpg's) as attachments on E-mails? The same is applicable to "written attachments", I would like to attach them as file ikons. How can this been done?
    Thanks,
    Hank

    Hey Hank Wefers,
    Thanks for using Apple Support Communities.
    Mail (Mavericks): Add attachments
    http://support.apple.com/kb/PH14914
    Add photos and other files:
    Drag files from the Finder, iPhoto, or another app into your message. Or click the Attach icon to choose a file. For photos, you can click the Photo Browser icon and drag a photo into your message. By default, Mail inserts images in their actual size.
    Mac OS X Mail: About PDF attachments
    http://support.apple.com/kb/ta22343
    Control-click the icon or visible portion of the PDF and choose "View in Place" or "View as Icon" as appropriate from the shortcut menu. Note that this only affects how you see the PDF in this message's window, it is not a permanent change.
    Have a nice day,
    Mario

  • How to use Source Code Control for Large Application?

    Hi, All!
    I would like to collect knowledge about "best practice" examples for using Source Code Control and project organization for relative large application (let's say approx 1000 SubVIs).
    Tools used:
    LabVIEW 8.0
    CVS Server
    PushOK CVS Proxy Client
    WinCVS
    With LabVIEW 8 we can organize large project pretty well. This described in article Managing Large Applications with the LabVIEW Project.
    I have read this article too: Using Source Control Software with LabVIEW In this Article Source Safe used, but with PushOK all looks nearby the same and works (some tricks for compare function are required).
    Example. Two developers working together on same project. Internally project is modular, so one developer will work with module "Analysis", and another one with "Configuration" without interferences. These modules placed into Subfolders as shown in example above.
    Scenario 1:
    Developer A started with modification of module "Analysis". Some files checked out. He would like to add some SubVIs here. So, he must also perform check out for the project file (*.lvproj), otherwise he cannot add anything into project structure.
    Developer B at the same time would like to add some new functions into module "Configuration". He also needed to check out project file, but this file already checked out by Developer A (and locked). So, he must wait until lvproj file will be checked in. Another way is mark *.lvproj files as text files in PushOK, but then one of developers will get conflict message by checking in and then merging will be necessary. This situation will coming very often, because in most cases *.lvproj file will be checked out all the time.
    Question: Which practice is better for such situation? Is Libraries better than folder for large project?
    Scenario 2:
    Developer C joined to the team. First, he must get complete project code for starting (or may be at least code of one Library, which assigned to him).
    Question: How it can be done within LabVIEW IDE? Or WinCVS (or other SCC UI) should be used for initial checkout?
    Scenario 3:
    Developer D is responcible for Build. Developers A,B,C have added lot of files into modules "Analysis", Configuration" and "FileIO". For building he need to get complete code. If our project splitted into folders, he should get latest *.lvproj first, then newly added SubVIs will appear in Project Explorer, then he should expand tree, select all SubVIs and get latest versions for all. If Project organized in Libraries, he must do the same for each library, isn't?.
    Question: Is this "normal way", or WinCVS should be used for this way? In WinCVS its possible with two mouseclicks, but I prefer to get all code from CVS within LabVIEW IDE recursively...
    That was a long post... So, if you already working with LabVIEW 8 with SCC used for large project, please post your knowledge here about project structure (Folders or Libraries) and best practices, its may be helpful and useful for all of us. Any examples/use cases/links etc are appreciated.
    Thank you,
    Andrey

    Regarding your scenarios:
    1. Using your example, let's say both developers checked out version 3
    of the project file. Assuming that there are only files under the
    directories in the example project, when Developer A checks in his
    version of the project, there will be new files in one section of the
    project separate from where Developer B is working. Developer B,
    notices that there is now a version 4 of the project. He needs to
    resolve the changes so will need to merge his changes to the latest
    version of project file. Since the project file is a text file, that is
    easy to do. Where an issue arrises is that after Developer B checks in
    his merged changes, there is a revision 5. When Developer A and B go to
    make another change, they get the latest version which will have the
    merged changes to the project file but not the referenced files from
    both Developer A and B. So when A opens version 5, he sees that he is
    missing the files that B checked in and visa versa. Here is where the
    developers will needs to manually use the source control client and,
    external to LabVIEW, get those new files.
    Where libraries help with the above scenario is that the library is a
    separate file from the project so changes made to it outside of the
    project do not require the project to be modified. So this time, the
    developers are using a single project again which time time references
    two libraries. The developers check out the libraries, make changes to
    the libraries, and then check those changes in. So when each developer
    opens the project file, since it references the project file, the
    changes to the library will be reflected. There is still the issue of
    the new files not automatically coming down when the latest version of
    the library is obtained. Again, the developers will needs to manually
    use the source control client and, external to LabVIEW, get those new
    files. In general, you should take advantage of the the modularity that
    libraries provide.
    2. As noted in the above scenario, there is no intrinsic mechanism to
    get all files referenced by a LabVIEW project. Files that are missing
    will be noted. The developer will then have to use the source control
    provider's IDE to get the initial contents of the project  (or library).
    3. See above scenarios.
    George M
    National Instruments

  • How to use active X controls to read/write protect an excel or word document created by created by Save Report to File VI

    Hi all,
    I'm trying to creat a word and excel documents using Save Report to File VI. When wiring a password to this last VI, the document created are only protected against writing but not reading. How can I use active X controls to password protect these documents against reading?
    Thanks a bunch!
    O

    There is no predefined functionality available in LabVIEW. So you have to implement this on your own.
    It seems to me that you own the Office Report Generation Toolkit. You can use the Excel Get ActiveX References.vi from the Excel Specific >> Advanced palette to get access to the "generic" ActiveX Excel references. Starting from this point, you can use property and invoke nodes to get to the setting you are going to modify.
    Please refer to this link for information on Excel password protection. I have not searched for the object giving you access to those settings though....
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • How to use OEM grid control to find any database not in archivelog mode?

    Hello,
    currently we have 130 databases, say, if I want to pick out any database currently NOT in archivelog mode, is there a quick way to find out ?
    by using OEM grid control
    or
    some trick similar,
    but really don't need to check each database manually.
    thank you very much!

    This query works in 12c - please run as SYSMAN.
    It is based on undocumented assumptions though +( AND key_value = 'NOARCHIVELOG')+.
      SELECT *
      FROM SYSMAN.MGMT$GROUP_DERIVED_MEMBERSHIPS O ,
        SYSMAN.MGMT$TARGET T ,
        sysman.MGMT$AVAILABILITY_CURRENT st
      WHERE
      o.member_target_type     IN ('oracle_database', 'rac_database')
      AND ( t.target_type           ='rac_database'
      OR (t.target_type             ='oracle_database'
      AND t.type_qualifier3        != 'RACINST'))
      AND o. member_target_guid     = t.target_guid
      AND t.target_guid             = st.target_guid
      AND st.availability_status    = 'Target Up'
      AND ( EXISTS
        (SELECT *
        FROM sysman.mgmt$metric_current i
        WHERE I.TARGET_GUID = O.MEMBER_TARGET_GUID
        AND metric_name     = 'archFull'
        AND Metric_Column   = 'archTotal'
        AND metric_label    = 'Archive Area'
        AND column_label    = 'Total Archive Area (KB)'
        AND key_value       = 'NOARCHIVELOG'
        ));Another way to achieve the goal is to push extended metrics (SELECT LOG_MODE FROM V$DATABASE) on each DB, and monitor the values they return to the repository. This is an example for a (slightly) different problem - http://iiotzov.wordpress.com/2012/08/08/how-to-use-the-new-oem-12c-metric-extensions-to-enforce-enterprise-wide-custom-policies .
    OEM Repository has many other great uses as well - http://iiotzov.files.wordpress.com/2012/05/oem-repository-a-second-look.doc , http://iiotzov.files.wordpress.com/2011/08/iotzov_oem_repository.pdf
    Iordan Iotzov
    http://iiotzov.wordpress.com/

  • I don't understand how to use the volume control on the new iphone headphones

    I just bought the new style earphones for my iphone and it has a new volume control -- how does it work?  On the old one you just pushed up or down for volume control but now it just increases volume for the time you hold it down?  Does anyone know how to use this properly?

    I have had good success with the System Font Panel. Now all of a sudden, I only get part of it. Any suggestions on how to restore the entire panel? There are no change size options in the corners like in some dialog boxes. I was going to paste what I have here, but for some reason, paste is not available.

  • How to use LabView to control Primera Bravo II CD burner?

    I am trying to use LabView to control the Primera Bravo II CD burner and label printer. The software that controls the Bravo II is PTPublisher. How to use LabView to communicate/control the PTPublisher? Please help, Thanks

    Hi Qian,
    I installed PTPublisher on a virtual machine, and I was wondering what kind of tasks you wanted to control within LabVIEW.  From the program GUI, it appears like the only way to access functions is via mouse clicks.  Do you know of any other way to control the Bravo II CD burner besides the PTPublisher software?  If not, does the PTPublisher allow you to control it in some way other than clicking?
    Peter K.
    National Instruments

  • How to use MS TreeView Control in Forms 5.0 ?

    I want to Use Microsoft TreeView Control in forms as my user demands a hierachical view of data . he also wants to update data same as we see in windows explorer left side pane, (drag - drop - copy -paste). Can any one tell me hw to do that. i have added the ocx file to forms but i want to know what to write to accomplish that ??
    Please help ???

    MS Treeview is an activeX control. You may have to go through the MSDN to find out how to import images.
    Jeremy

Maybe you are looking for

  • Macbook not booting, faint ticking noise?

    Hi there, I'm hoping you guys can give me a few pointers here. I have a mid 2007 black 13" Macbook that I have been having problems with. There have been two previous issues which may or may not be related. Over the last three years, this Macbook has

  • How do I insert multiple pages in Pages

    In Pages, how do I insert more than one new page at a time? Using InDesign, for example, I can command the program to add, say, 22 (or however many) new pages to the document. I can't seem to find a way to do that kind of thing in Pages. I'm using ve

  • Figuring out how may tacks are on my Zen nano p

    is there a way to see how many tracks are on your player thorugh either creative media source or wmp 0? thanks

  • Safari PDF no show

    When I click a pdf link in safari, it goes to a black screen. I have done the right click info open with thing. Tried re-installing safari, and nothing has fixed it. Anyone have any advice?

  • Hanging

    installed adobe lightroom 3.3 - iphoto hangs, time machine backups hang and 'mds' process is stuck at 100% on 1 proc on 4 proc Imac.System becomes sluggish. Have tried deleting spotlight indexing file - problem still manifests after a few minutes.