How to use parallel sequence for split the operation qty. urgent or other o

PP guru
My scenario is as follows.
I ve one material suppose…xyz.
For that material I' ve created bom, routing.
In routing I' ve mention only one operation. 0010.
Now I' ve the production order of 1000 kg.
I want to use two work centers to run this production order. ( e.g.work center a and b)
In routing I used work center a.
In short I want split that operation.
So what I ve to do or use parallel sequence and how???
or else is there any other option to split the order to two or more machines/work center?
Pls explain me in brief.
Regards,
Ram

Hi,
  If you want to carry the production with two different work centers , first you need to split the operation qty.
For this in the order type dependent parameters OPL8
in the controlling tab page enable the indicator Cost collector
and set the default rule as PP2.
  Create a Product cost collector with KKF6N.
   Now in the production order , select the operation and choose functions--->>> split.
   Now enter the operation split quantity and execute.
   Now in MD04 you can see two production order.
   In the second production order change the work center in the operation overview as desired and save.
  Regards,
nandha

Similar Messages

  • How to use parallel sequence in capacity planning.

    How we can use parallel seq in capacity planning?we have two machines which can be run parallel for production ,now how  to distribute capacity load? suppose for the production of 100 km,we required 1000 min when it is produced through only one machine.Now if 2 machines are used simultaneously we required 500 min.How to see this in capacity planning?

    Dear,
    For calculating Available capacity you have options like minimum capacity, normal capacity and maximum capacity. You can select this option in work center-capacity tab for individual capacity category.
    With parallel sequence and with both machines you can select maximum capacity option and plan your capacity.
    Hope this is helpful.
    Regards,
    Prasad

  • How to use 20 MHz clock of the 6602 Timing card on other boards?

    Hello,
    I have a 1042 PXI with 6602 timing card and several other boards including 6534 Digital I/O board and 5122 Digitizer.
    I want these boards (6534 and 5122) to use the 20 MHz clock of the 6602 board as their Sample Clock.
    But when I set "/TimingIO/20MHzTimebase" as the source of the Sample Clock for the 6534 board I get the following error sometimes (sometimes everything works fine) :
    """Error -200621 occurred at DAQmx Wait Until Done.vi:2
    Onboard device memory underflow. Because of system and/or bus-bandwidth limitations, the driver could not write data to the device fast enough to keep up with the device output rate. Reduce your sample rate, or reduce the number of programs your computer is executing concurrently. """
    When I use "OnboardClock" as the source of the Sample Clock for 6534 I never get this message. I tell 6534 to use 6602's 20 MHZ clock by connecting
    "/TimingIO/20MHzTimebase" terminal to the appropriate input of the
    "Sample Clock vi" in the 6534's task. Output rate of the 6534 that I use is (much) less than 1 MHz.
    Could somebody explain the source/reason of the error message above? It seems like 6534 can not use 6602's 20 MHz clock though it has 20 MHz oscillator itself...
    Is there a way to use 20 MHz clock of the 6602 for 6534?
    Thanks in advance!

    Hi Ampm,
    The two answers are related to each of the answers:
    1) In this knowledgebase we can see that actually the 6602 cannot
    export his clock into PXI_Star. Since your digitizer cannot received but from
    this line, we need to find a different solution (see below).
    2) PXI_Star is actually a signal and should be named something
    like this “/Slot5/PXI_Star”. Make sure you PXI chassis is configured in MAX.
    There are two possible approaches:
    1)     
    I would suggest to PLL all
    clocks to the PXI 10 MHz clock. This takes full advantage of the hardware you
    have.
    2)     
    Export the 6602 20 MHz clock
    on a front panel PFI line and externally connect it to the CLK IN of the 5122.
    Good luck,
    Gerardo O.
    RF Systems Engineering
    National Instruments

  • How to use custom function for formatting the Line Chart Axes?

    Hi...
    I'm using a Line chart who's y axis value range from 0 to 50000. This is a number which it gets from it's dataProvider. I want to format this and show it as
    $50,000
    $40,000
    $30,000
    $20,000
    $10,000
    $0
    instead of
    50000
    40000
    30000
    20000
    10000
    0
    Here's my linechart code:
    <mx:LineChart id="revTimeLineChart"
                width="100%" height="100%"
                showDataTips="true" >
                <mx:horizontalAxis>
                   <mx:CategoryAxis id="lcCatAxis" categoryField="name"/>
                </mx:horizontalAxis>
                <mx:series>
                   <mx:LineSeries id="ls" yField="revenue" displayName="Revenue" showDataEffect="{slideIn}"/>      (yField is what I want to format....)
                </mx:series>
    </mx:LineChart>
    Can you please let me know how can this be achieved?
    Cheers!
    Deepak

    Hi,
    You could do something like this,
    http://www.codersrevolution.com/index.cfm/2008/10/14/Flex-Charting-Format-your-X-and-Y-Axi s
    hope it helps!
    Regards ,
    Bhavika

  • I have dual boot labs that I set up up for a school.  The Partitions consist of mountain lion and windows 7.  I use bootlicker as the software for selecting the operating systems.  When I choose windows, it takes just under 2 minutes to go to the login sc

    I have a dual boot lab that I set up for a school.  The partitions consist of Mountain Lion OSX and Windows 7 Ent.  I use bootpicker software for choosing the operating system at startup.  When I select the windows partition, it take just under 2 minutes from selection to the windows login screen.  It seems to take incredibly long for the mac to "shut down and hand over the operating system to windows. 
    Do you have any suggestions on how to get this timing faster?
    Thanks for any ideas/input

    The only suggestion I can make is to look ar ReFind (previuosly ReFit). Startup mamangement is one of its features.
    But
    It is very powerful so test it for yourself before deploying it. Some of the functions are best kept out of the hands of the curious, or 'playful'
    And you never answered this question.
    Tell me what the needs are, do the users always need to choose Windows or is this a variable?

  • Keyboard error with '@' when in WindowsXP (using Parallels Desktop for Mac)

    When I go to type '@' when in WindowsXP (using Parallels Desktop for Mac) the symbol ' " ' appears; I have to type ' " ' to achieve the ' @ ' symbols. Can anyone help?

    Try switching the keyboard layout in XP to other countries. Maybe US from UK.

  • How to use parallel

    Hi
    Any body help me to how to use parallel and add window8

    Follow the instructions from the Parallels User Guide here.

  • How do i use parallel compression for 4 drum tracks in Logic pro 7.2.3 Please

    how do i use parallel compression for 4 drum tracks in Logic pro 7.2.3 Please. my version is 7.2.3 and my son did his drums on 4 tracks. 2 OH's 1 Kick and 1 Snare. Were confused because we cant figure out how to do parallel compression on the older logic version 7.2.3?

    I can't remember when the Aux tracks became the new buss tracks, so I'll spell this out using busses.
    The way I do it, is I assign all my drum tracks to a buss, say buss 1.
    Then, on buss 2, I assign it's INPUT to buss 1.
    So buss 1 (all the drums) are feeding into buss 2 simultaneously.
    Put a compressor on buss 2, turn the fader down all the way, then as the track is playing, bring buss 2's fader up slowly, until you hear the effect you're after.
    You could also do this using sends on the 4 drum tracks, set to feed the buss with the compressor on it.
    I hope I haven't forgotten anything particular to that version of Logic. See if this helps...

  • How can i write a vi in using parallel port for digital inputs

    Dear all,
    i am a beginner user of LabVIEW and i want to write a vi in using parallel port for digital I/O. After reading the article "Using the Parallel Port in LabVIEW
    " and download the parallel.zip, i know how to write the vi for output, but i still don't know how to write the input one.i've try to use a Inport.vi to test, but nothing change when i set pin2-9 to high. (my computer:win2K & LabVIEW 6.1)
    Can anybody teach me how to write it?
    Can anyone write the vi for me too?
    Thanks all!
    p.s.i've already install the "accessHW.exe"

    Are you using VISA or the accessHW VIs? You may need to goto the bios and set the parallel port to run in spp mode or standard mode. This is the simpliest configuration and where you should start.
    As far as writing the VI goes, just copy the diagram out of the tutorial you mentioned.

  • How to use parallel flowed subforms begining at the same position.

    How to use parallel flowed subforms begining at the same position in my form.
    Ex
    Subform1
    Subform2
    Subform3
    DropDownList1
    DropDownList1
    DropDownList1
    I would like to repeat  with a button the 3 subforms in parallel
    Subform1
    Subform2
    Subform3
    DropDownList1
    DropDownList1
    DropDownList1
    Subform1
    Subform2
    Subform3
    DropDownList1
    DropDownList1
    DropDownList1

    Post your question in the LiveCycle Designer forum.

  • How to use same actions for differ pop-up

    Hi gurus,
    I am using 2 popup in a view.same popup's having same buttons 'Yes', 'No'.when i use 1st one i have to create an action for that Yes button where i put my code for that particular Action.
    But when i used 2nd one the action define for that is not acceptable with differ name.it takes only standard one.
    Now my Query is : How to use same actions for differ pop-up buttons with in a similar view?Where i put my code.
    Plz sugges me.
    <b>Points will be sured.</b>
    Sanket sethi

    Hi,
    Take one integer value attribute in the context of view
    when you r performing action on POP1 set it's value to 1
    when you r performing action on POP2 set it's value to 2
    create one method which receives integer argument, say diaplay(int a)
    In the action call display(wdContext.currentContextElement().get<intvariable>()) by passing the value in the context attribute
    in display() method, Check the value of integer variable..
    if it is 1 then perform action related to POP1
    if it is 2 then perform action related to POP2
    Regards
    LakshmiNarayana

  • How to use same actions for differ pop-up buttons

    Hi gurus,
    I am using 2 popup in a view.same popup's having same buttons 'Yes', 'No'.when i use 1st one i have to create an action for that Yes button where i put my code for that particular Action.
    But when i used 2nd one the action define for that is not acceptable with differ name.it takes only standard one.
    Now my Query is : How to use same actions for differ pop-up buttons with in a similar view?Where i put my code.
    Plz sugges me.
    <b>Points will be sured.</b>
    Sanket sethi

    Hi ,
    u can use the method SUBSCRIBE_TO_BUTTON_EVENT of the IF_WD_WINDOW interface ... to handle the event fired by the popup .....used this method after creating the popup window ...
    regards
    Yash

  • How to use one report column into the another report in obiee

    How to use one report column into the another report in obiee

    i dont want to use column as a filter for another report it should be report column for another report
    Thanks,
    Vivek

  • How to Use PM BAPI for equipment Master upload : BAPI_EQUIPMENT_SAVEREPLICA

    Hi ,
      How to use PM BAPI for equipment Master upload : BAPI_EQUIPMENT_SAVEREPLICA.
      May i know what are the input parameters & fields mandatory
      for each Table structures ct_data , ct_datax , it_descript , it_longtext.
      Can any one explain me Step by Step Process.
      B'cos i tried with below code. Equipment is not getting created.
      wa_itab-equipment_ext = '000000000100000001'.
      wa_itab-descript      = 'Test 2 -> Lube Oil Pump'.
      wa_itab-text_language = 'EN'.
      wa_itab-sdescript     = 'Short Description'.
      APPEND wa_itab TO it_itab.
      CLEAR  wa_itab.
      LOOP AT it_itab INTO wa_itab.
        ct_data-ta_guid       = '000000000000000001'.
        ct_data-equipment_ext = wa_itab-equipment_ext.
        ct_data-descript      = wa_itab-descript     .
        ct_data-valid_date    = sy-datum.
        ct_data-equicatgry    = 'M'.
        APPEND ct_data.
        CLEAR  ct_data.
        ct_datax-ta_guid       = '000000000000000001'.
        ct_datax-equipment_ext = 'X'.
        ct_datax-equipment     = 'X'.
        APPEND ct_datax.
        CLEAR  ct_datax.
        it_descript-ta_guid       = '000000000000000001'.
        it_descript-text_language = wa_itab-text_language.
        it_descript-descript      = wa_itab-sdescript    .
        APPEND it_descript.
        CLEAR  it_descript.
        it_longtext-ta_guid        = '000000000000000001'.
        it_longtext-text_language  = wa_itab-text_language.
        it_longtext-text_id        = 'LTXT'.
        it_longtext-text_line      = 'SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS'.
        APPEND it_longtext.
        CLEAR  it_longtext.
        it_longtext-ta_guid        = '000000000000000001'.
        it_longtext-text_language  = wa_itab-text_language.
        it_longtext-text_id        = 'INTV'.
        it_longtext-text_line      = 'aaaaaaaaaaaaaaa'.
        APPEND it_longtext.
        CLEAR  it_longtext.
        it_longtext-ta_guid        = '000000000000000001'.
        it_longtext-text_language  = wa_itab-text_language.
        it_longtext-text_id        = 'INTV'.
        it_longtext-text_line      = 'bbbbbbbbbbbb'.
        APPEND it_longtext.
        CLEAR  it_longtext.
        it_longtext-ta_guid        = '000000000000000001'.
        it_longtext-text_language  = wa_itab-text_language.
        it_longtext-text_id        = 'INTV'.
        it_longtext-text_line      = 'cccccccccccccccc'.
        APPEND it_longtext.
        CLEAR  it_longtext.
        CALL FUNCTION 'BAPI_TRANSACTION_COMMIT'.
      call BAPI-function in this system
        CALL FUNCTION 'BAPI_EQUIPMENT_SAVEREPLICA'
          TABLES
            ct_data     = ct_data
            ct_datax    = ct_datax
            it_descript = it_descript
            it_longtext = it_longtext
            return      = return
          EXCEPTIONS
            OTHERS      = 1.
        IF sy-subrc = 0.
          CALL FUNCTION 'BAPI_TRANSACTION_ROLLBACK'.
          WRITE : 'Successful'.
        ENDIF.
        IF NOT return IS INITIAL.
          LOOP AT return.
            IF return-type = 'A' OR return-type = 'E'.
              WRITE : 'Error'.
            ENDIF.
          ENDLOOP.
        ENDIF.
        REFRESH  return.
      ENDLOOP.
    Regards
    SUrendar

    Hi ,
      How to use PM BAPI for equipment Master upload : BAPI_EQUIPMENT_SAVEREPLICA.
      May i know what are the input parameters & fields mandatory
      for each Table structures ct_data , ct_datax , it_descript , it_longtext.
      Can any one explain me Step by Step Process.
      B'cos i tried with below code. Equipment is not getting created.
      wa_itab-equipment_ext = '000000000100000001'.
      wa_itab-descript      = 'Test 2 -> Lube Oil Pump'.
      wa_itab-text_language = 'EN'.
      wa_itab-sdescript     = 'Short Description'.
      APPEND wa_itab TO it_itab.
      CLEAR  wa_itab.
      LOOP AT it_itab INTO wa_itab.
        ct_data-ta_guid       = '000000000000000001'.
        ct_data-equipment_ext = wa_itab-equipment_ext.
        ct_data-descript      = wa_itab-descript     .
        ct_data-valid_date    = sy-datum.
        ct_data-equicatgry    = 'M'.
        APPEND ct_data.
        CLEAR  ct_data.
        ct_datax-ta_guid       = '000000000000000001'.
        ct_datax-equipment_ext = 'X'.
        ct_datax-equipment     = 'X'.
        APPEND ct_datax.
        CLEAR  ct_datax.
        it_descript-ta_guid       = '000000000000000001'.
        it_descript-text_language = wa_itab-text_language.
        it_descript-descript      = wa_itab-sdescript    .
        APPEND it_descript.
        CLEAR  it_descript.
        it_longtext-ta_guid        = '000000000000000001'.
        it_longtext-text_language  = wa_itab-text_language.
        it_longtext-text_id        = 'LTXT'.
        it_longtext-text_line      = 'SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS'.
        APPEND it_longtext.
        CLEAR  it_longtext.
        it_longtext-ta_guid        = '000000000000000001'.
        it_longtext-text_language  = wa_itab-text_language.
        it_longtext-text_id        = 'INTV'.
        it_longtext-text_line      = 'aaaaaaaaaaaaaaa'.
        APPEND it_longtext.
        CLEAR  it_longtext.
        it_longtext-ta_guid        = '000000000000000001'.
        it_longtext-text_language  = wa_itab-text_language.
        it_longtext-text_id        = 'INTV'.
        it_longtext-text_line      = 'bbbbbbbbbbbb'.
        APPEND it_longtext.
        CLEAR  it_longtext.
        it_longtext-ta_guid        = '000000000000000001'.
        it_longtext-text_language  = wa_itab-text_language.
        it_longtext-text_id        = 'INTV'.
        it_longtext-text_line      = 'cccccccccccccccc'.
        APPEND it_longtext.
        CLEAR  it_longtext.
        CALL FUNCTION 'BAPI_TRANSACTION_COMMIT'.
      call BAPI-function in this system
        CALL FUNCTION 'BAPI_EQUIPMENT_SAVEREPLICA'
          TABLES
            ct_data     = ct_data
            ct_datax    = ct_datax
            it_descript = it_descript
            it_longtext = it_longtext
            return      = return
          EXCEPTIONS
            OTHERS      = 1.
        IF sy-subrc = 0.
          CALL FUNCTION 'BAPI_TRANSACTION_ROLLBACK'.
          WRITE : 'Successful'.
        ENDIF.
        IF NOT return IS INITIAL.
          LOOP AT return.
            IF return-type = 'A' OR return-type = 'E'.
              WRITE : 'Error'.
            ENDIF.
          ENDLOOP.
        ENDIF.
        REFRESH  return.
      ENDLOOP.
    Regards
    SUrendar

  • How to use Web Serivce for not jsr 172 phone

    Hi:
    Is anyone know, how to use web service for phones that only have standard J2ME package installed (without jsr 172 web service packagenstalled)?
    thank you

    Hi,
    I think you need to write the code for this from scratch (built on top of existing HTTP functionality). There may be open-source J2ME code you could use. I've never tried this so I'm afraid I don't know any more. But maybe that is what you were asking... i.e. does anyone have code that does this already...
    Tx,
    Sam

Maybe you are looking for

  • Mac mini and flash

    Does the Mac Mini support a Flash Player?

  • Customer master data table KNVV is missing

    Hi All I a trying to cancel the billing document using transaction VF11. System shows error as " customer XYZ customer master data table KNVV is missing" Please advice how to proceed? Thanks and regards satyaprasad

  • Inserting XML(Master Detail like PO)into Database

    hi, Can any one suggest me which tools or what methodolgy I should use to insert master detail data like one header and multiple rows into database. I am unable to insert into database through object view with the help of XML SQL utility for Java. Pl

  • Can't access My Devices Portal - Don't have permissions

    Just upgraded from ML/Server app with Profile Manager to Mavericks and upgraded Server App to 3.0.1. Profile manager portal is wirking fine and all data are migrated. When trying to access Profile Manager My Devices Portal, we have the following erro

  • Iphone 5 using burning data and battery

    I have an Iphone 5 which uses abnormal amounts of data. even with no programs running in the background it uses around 1 mb pr second. this is monitored in an app. the phone is hot and the battery goes from full to empty withing 5-6 hours. using the