HP Blade Cisco MDS 9124e

Hello all,
I got a new c7000 with some MDS swithes.  I'm trying to get to the latest software.  I started at 4.1.x and can only get to 4.2.9.  I'm then trying to upgrade to 5.0.4d it fails.  In Fabric Manager it fails during copying and when i try to install via CLI i get the following:
-- FAIL. Return code 0x       0 (success).
Install has failed. Return code 0x40930068 (Runtime check failed).
Please identify the cause of the failure, and try 'install all' again.
Currently i have 5.0.7 FM installed.  So question is can i get to 5.0? 
Another question is can i get to 5.2.2 with using FM 5.0.7?  Or do i have to install DCNM?
Thanks for your time and support,
Nick

You can map internal to external using VSANs...Put the blade in slot x in vsan xxx and the external internal interface also into vsan xxx.
The real question is why you need to do this?  The external ports are usually used for ISLs to a core swtich, and they can be TE ports which carry multiple VSANs.
If you install a storage unit into one of the external ports, you can limit access by zoning.  The blade port and the external port would need to be in the same VSAN, and then on that VSAN you can create a zone/zoneset to permit the blade to access the storage port.
There really is no need to map traffic between the internal and external ports per se.
If you can provide more details as to what you need to accomplish, we can provide a more accurate reply.
Unless you are well versed in FSPF and fiber channel routing, I would steer clear of the fcroute commands or you could end up with asymetric traffic flows.
HTH,
Mike

Similar Messages

  • Interconnecting CIsco MDS 9222i to the HP C-Blade enclosute VC-FC Virtual connect module

    Hi,
    Anyone had the experience of interconnecting the CIsco MDS 9222i to an HP Blade system through the VC-FC virtual connect module?
    When i connect my MDS switch to the module, the VC-FC ports dont log in to the MDS. Could i be missing out on something? I have configured the MDS to use the default VSAN 1 and tried configuring the ports as F-ports but nothing worked, even with the port mode put on auto they still take on the F-port role and still the VC-FC module doesnt log in.
    Your help and support will be appreciated
    jerrysimila

    i wanna use the CLI though i also have the fabric manager at my disposal. would you kindly
    share a sanitised version of ur running config for the mds that does the FCIP replication to the DR i see if i can make head out of it then i
    f i face any challenge will holla at u. you can email me [email protected]
    My set up is as follows, ive got 2 MDS 9222i at the primary site in active-standby mode, one connects to the active VC while the other connects to the standby VC of the blade system. Then i have a similar set up for the DR. Good thing is that am first setting everything up here in my Data Centre, then test before sending the configured equipment to the DR. So i have much freedom to get dirty with the equipment, and its not a live environment yet.
    Kindly let me know the step-by-step procedure of having the FCIP set up.

  • Cisco MDS 9509 and HP Blade server problem

    I have a big problem , when i connected to MDS 9509 to HP VC-FC 8GB the module in MDS 9509 did not detect the HP module . I think this will be because MDS 9509 uses VSAN technology , but HP blade is not support this feature. Please help me

    I am fairly certain that the HP blade chassis has HP branded Brocade FC switches. These switches need to be placed into AG mode and rebooted. On the Cisco MDS core the NPIV feature must be enabled.
    Here is more info on the Brocade AG mode -
    http://www.brocade.com/solutions-technology/technology/platforms/fabric-os/access_gateway.page
    http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/AccessGateway_DS_02.pdf
    Cisco NPIV info
    http://www.cisco.com/en/US/prod/collateral/ps4159/ps6409/ps5989/ps9898/white_paper_c11-459263.html

  • Cisco MDS 9513/9509 LDAP/AD Auth via SSH & Fabric Manager

    Hello Folks,
    I am trying to look for working config with LDAP auth over SSH. I know how to use them over TACACS+ & Radius. But due to other internal issue, currently I am trying to get the Cisco MDS to directly auth using LDAP/AD. Also, I see no option of LDAP/AD in FM(Fabric Manager), but just TACACS+, Radius, LocalFM and MDS. Do using MDS uses default auth(ie whatever AAA authentication is configured for ? or local DB on the switch).  Does the new DCNM supports LDAP/AD auth on the GUI ?
    Larger goal is SSH(CLI) & FM(GUI) using the same LDAP/AD auth. I understand the snmp-server user issue. But once I have SSH working over LDAP/AD I can figure that out to..
    Here's what I need to ensure when using LDAP/AD auth
    1) What is the exact config for this LDAP/AD auth
    2) How do I ensure that network-admin & network-opertor roles are assigned when certain AD Groups Logins in Like ADMIN-AD-GROUP , OPERATOR-AD-GROUP --> trying to login to the switch
    3) Also using SSL port for LDAP, do details are encrypted over the network.
    4) Do I need to use the PASSWORD in paintext when BINDING the BaseDN ?, can it be an encrypted password.
    Appreciate any info on this. Thanks for your time.

    As of DCNM 6.1 (aka - Fabric Manager Server) we support LDAP authentication adding to existing Radius, TACACS+, local and switch authentications.  You can upgrade from Fabric Manager 5.0 to DCNM 5.2 to DCNM 6.1 if you like to keep current performance, events, config data alive.  We do recommend fresh install as we don't know what state your server dabatabase might be in.  Including some links for you to help out with deployment and best practices (see release notes).
    Resources:
    Main Website:
    http://www.cisco.com/go/dcnm
    How To Video Series:  http://www.cisco.com/en/US/prod/netmgtsw/ps6505/ps9369/cisco_dc_nm_video_library.html
    Install and Licensing Guide:
    http://www.cisco.com/en/US/products/ps9369/prod_installation_guides_list.html
    Evaluation Licenses: http://tools.cisco.com/SWIFT/LicensingUI/Home?FormId=65
    Download Linux and Windows Executables: http://www.cisco.com/cisco/pub/software/portal/select.html?&i=!m&mdfid=281722751
    Data Sheets: http://www.cisco.com/en/US/prod/collateral/netmgtsw/ps6505/ps9369/data_sheet_c78-639737.html
    Install Guide: http://www.cisco.com/en/US/products/ps9369/prod_installation_guides_list.html
    Configure Guide:  http://www.cisco.com/en/US/products/ps9369/products_installation_and_configuration_guides_list.html
    API Programming Guide:
    http://www.cisco.com/en/US/products/ps9369/products_programming_reference_guides_list.html
    Reference Guide: http://www.cisco.com/en/US/products/ps9369/prod_technical_reference_list.html
    Release Notes: http://www.cisco.com/en/US/products/ps9369/tsd_products_support_general_information.html

  • Enabling NPIV in CISCO MDS 9500 Series

                       Hello!!!
    If i could get the response for my query.
    I need to enable NPIV as we have VM's to be created and allocate SAN storage to them so my CISCO MDS needs to have NPIV enabled. Following queries linked with this:
    1. Can i enabled NPIV on single Fibre Channel Port or it gets enabled on the complete SAN Switch
    2. Does enabling NPIV impact any other SAN operation. Also my 2- sites are connected via ISL, so is it important to enable NPIV across all my sites or i can enable it only at 1 site where my VM hosts are located.
    3. Any reference document for NPIV and related zoning concept.
    Thanks in advance.
    Faizul Mufti
    9958766711

    Hi,
    1. Can i enabled NPIV on single Fibre Channel Port or it gets enabled on the complete SAN Switch
    whole switch
    feature npiv
    2. Does enabling NPIV impact any other SAN operation. Also my 2- sites are connected via ISL, so is it important to enable NPIV across all my sites or i can enable it only at 1 site where my VM hosts are located.
    Will not impact any other SAN operation.  Non-disruptive.
    "feature npiv" is local to the switch, not fabric wide.  Use this command on any switch you want multiple flogi's on a single interface.
    3. Any reference document for NPIV and related zoning concept.
    I suggest zoning by pwwn
    Regards,
    David

  • ISCSI-to-FC routing in Cisco MDS 9000 Family

    Hi,
    I'm puzzled about support for iSCSI-to-FC routing in the MDS 9000 family. Earlier hardware such as the 9216i switch and the MPS-14/2 module had a feature to allow an iSCSI Initiator to connect transparently to an FC target. This equipment is now EOL and has been replaced by models such as the 9222i switch and the 18/4 Port Multiservice Module. The datasheets for these replacements strongly imply that they support iSCSI-to-FC routing in a similar way to the earlier products - for example "iSCSI for extension of the SAN to Ethernet attached servers - Extends the benefits of Fibre Channel SAN-based storage to Ethernet attached servers".
    I tried to find some hard technical info to confirm this. Chapter 4, "Configuring iSCSI" in "Cisco MDS 9000 Family NX-OS IP Services Configuration Guide Release 5.0(1a)" says that the feature is only available on the IP Storage Module, the 9216i switch, and the MPS-14/2 module, all of which are now EOL. It doesn't mention the replacement models in connection with this functionality, though they are mentioned elsewhere in the book for other features such as FC over IP. I've searched for documentation of the iSCSI support on the new models and the only document which seems relevant is this chapter - but it says it doesn't apply to these models.
    Do the replacement models support iSCSI-to-FC routing or not? The datasheets use wording nearly identical to the earlier models in this area, so I assume they do. If they do, how is it configured and where is it documented? I sent feedback on this to the documentation feedback address a while ago, but haven't had a reply.
    Many Thanks,
                                jjf

    The "Configuring iSCSI" chapter in both 3.3.3 and 4.1.1 documentation similarly talk about IPS and 14/2 modules but make no mention of 18/4, however I've used iSCSI on the 18/4 with both releases. I can only guess the same is true for 5.0 since I have yet to load 5.0 on any switches.
    In terms of other documentation I don't think there is any, but all the required information is presented in the "Configuring iSCSI" chapters however it's not the easiest thing to understand from the documentation. Following is the overview I sent to a teammate on how to setup iSCSI.
    1. configure Ethernet ports with ip addresses
      1a. add a route to the host, iSCSI client, via the gigabit interface 2. enable iscsi on the switch
      2a. enable iscsi on the module with the gige port
      2b. 'no shut' the iscsi interface corresponding to gige port
          e.g. gige3/4 -> iscsi3/4
      2c. no additional configuration of the interfaces is needed, although at some point turning on authentication would be a good idea
    3. create iscsi initiator
      3a. use the clients ip address as the initiator name, using the node name would be better but I haven't tried it that way so ymmv
          e.g. 'iscsi initiator ip-address xxx.xxx.xxx.xxx'
      3b. use a "system assigned" nwwn and set it static
          e.g. 'static pWWN system-assign'
      3c. allocate one "system assigned" pwwn and set it static
          e.g. 'static pWWN system-assign 1'
      3d. assign vsans, an iscsi initiator can be in more than one vsan
          e.g. 'vsan xxx'
    4. create targets
       spcsw1(config)# iscsi virtual-target name iqn.000190300646.fa02cb
       spcsw1(config-iscsi-tgt)# pwwn 50:06:04:8a:d5:f0:79:a1
       spcsw1(config-iscsi-tgt)# initiator ip address xx.xx.xx.xx permit
    5. zone the iscsi initiator's pwwn to the target pwwns, use 'sh iscsi initiator configured' to see the pwwn
    6. configure the hosts iscsi initiator, usually not much more than specifying the ip address of the gige port on the MDS

  • Cisco MDS 9418 switch doubt

    Hi Team,
    We have an issue, whether the cisco MDS 9418 switch supports FCIP feature.
    We are planning to migrate the data from our old data center over WAN to the EMC VNX storage box in other location.
    In our old data center we have 2 FC cisco switches connected to the EMC clariion storage array. Inorder to replicate data from clariion box to EMC VNX box over WAN ,it can be done via FCIP.
    I wanted to know if we can use insert the FCIP converters into these MDS 9418 switch or do we need to have separate FCIP converters.
    Do we need FCIP converters on both sides for doing replication over FCIP.
    For clear understanding please see the attachment.
    Will waiting for your response......
    Regards,
    Pranav.

    Hi,
    Since the 9148 does not have IP interfaces, something will be needed to tunnel the FC into IP (FCIP) such as an MDS 9222i, which has both FC interfaces and GigE interfaces and supports FCIP.
    Regards,
    David

  • Cisco MDS 9148 Inventory Collection

    Hi
    I get the following error on an inventory collection of a MDS 9148 (NOS 5.0.4). I have tried deleting and recreating the device.
    RME 4.3.1
    RICS0001:Internal Error,unable to process the collected data from the device.
    [ Thu Dec 30  13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.LibInventory.PortInterfaceAGI_RFC1213_HelperMethods,getIfTableEntriesFromDevice,759,Entry speed after if block: 1000000000 Index value : 101191680
    [ Thu Dec 30  13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,58,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:populating AssetAG attributes, begins...
    [ Thu Dec 30  13:48:53 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,57,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,64,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:AssetAG Collection aborted com.cisco.nm.xms.xdi.ags.system.CollectionFailedDeviceSensed: java.lang.ArrayIndexOutOfBoundsException: 5 >= 5
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,549,DP time is 20 seconds for 172.23.32.129
    [ Thu Dec 30  13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor,458,
    java.lang.NullPointerException
    at com.cisco.nm.rmeng.inventory.ics.invdata.containment.ContainmentAGInvData.compare(ContainmentAGInvData.java:103)
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processContainmentAG(InvDataProcessor.java:864)
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:330)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
    at java.lang.Thread.run(Thread.java:595)
    [ Thu Dec 30  13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,935, Exception occured in process method while processing: 172.23.32.129 null
    ICSException
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:473)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
    at java.lang.Thread.run(Thread.java:595)
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1191,No Trap
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1203,CALLING SELF TEST
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1207,DONE WITH SELF TEST

    Hi Naem,
    have just read the othre reply's, the intresting bit it is in the MDF.
    - <DEVICE NAME="Cisco  MDS 9148 Multilayer Fabric Switch" MDFID="282867260" CISCOMDFID="282867260">
    <SYSOID OID="1.3.6.1.4.1.9.12.3.1.3.841" NAME="OID:1.3.6.1.4.1.9.12.3.1.3.841" />
    The device adds ok, I just can not run an Inventory but can run a backup !
    Thanks

  • Cisco MDS series switch details

    Hello I 'm new to CISCO  Switch world.
    I 'm working as Clariion Admin and have have taken up the responsibilty to manage switches.Since,i am a novice i need little guidance on how work on cisco switches.I know the Zoning (how zoning done on MDS 9000 series switches) part ,but would like to venture deep into the details on CISCO MDS series switches.
    Like, the use of Port channels etc.
    Will really appreciate if some one can help me with a link or place ( not the configuration guide) where in i can find details on concentrated more on the theory part .
    Thanks in advance!

    Actually the best info is in the configuration guides.  There are some external companies that run training sessions on the MDS to provide in depth training.  There is the MDS cookbook available on CCO that is also a good point of information.    If you search on 'MDS white papers' after you login into Cisco.com, there are several good documents that might meet your needs.
    Hope this hels,
    Mike

  • Migrating from Brocade 2800/ 3900 to Cisco MDS 9509

    What is the best procedure from migrating from Brocade 2800/3900/12000 to Cisco MDS 9509 especially connected to HP-UX and AIX server.
    Without any Downtime I should be able to migrate these servers.
    I thought about these options:
    1. Use vgexport and vgimport or exportvg and importvg (AIX) after connecting to Cisco MDS. But this requires complete downtime on the application.
    2. Take one path down or HBA down and switch the cable and vgextend the devices.
    Please let me know if somebody has procedure.
    I was successful in HP-UX server using the second options but I cant see all the LUNs. That might be array specific problem also.
    If anybody has detailed procedure on migrating this scenario. please let me know.
    We are using Persistent FCIDs on our MDS switches.
    Thanks in Advance

    After connecting 1 cable from server HBA to Cisco S/w, why you are not able to see all LUNs, did you cross-check that...I mean HBA Configuration (max 256 LUNs) or Disk Array library driver to be installed on host side.if that can be sorted out, you can mirror the volumes across the disk arrays.are you using HDS Arrays? I don't know but what is vgextend command you are mentioning...
    also did you take a reboot of server or is it online addition on new LUNs...
    Also any how if you are not able to see all LUNs that is going to be an issue later as well for migration...pls cross-check that...

  • Does cisco MDS 9000 switch by default set a little higher R_T_TOV?

    Hi, All:
    Not sure anyone has done LOS for cisco MDS 9000 switch before. I tried to insert code violation which is equal to 103ms but only see link reset but not NOS/OLS. is it because that Cisco MDS has default higher ? Or can we set R_T_TOV on switch?

    Hi Larry - [this|http://lists.apple.com/archives/usb/2008/Oct/msg00021.html] was the only thing I could find about transactions timing out, but since you don't have anything plugged in, it really doesn't apply. Have you tried resetting your SMU?
    If that doesn't work, run Disk Utility from your install disc and see what it comes up with. Your suspicion that the MB may be faulty is probably correct, and if you are still within the 90 day warrant period, you should call the repair place and have them replace it yet again.

  • Scsi device discovery in Cisco MDS switches

    I was using this device discovery to find out how many luns can be seen on that server.
    I tried to use discover scsi-target command and it does not give much useful information. and I do not want to add the OS WWNS on my LUN security in addition to HBA WWNS for the host group on the array end.
    The problem that I am having is that I can see 7 LUNs out of 9 when I connect to Cisco MDS where as in brocade I can see all the LUNs.
    I checked the LUN security and zoning and everything seems to be correct.
    If Cisco SAN OS has commands where by I can see what LUNs can be seen on the switch, that would be really helpful. But It looks like LUN/LDEV info cannot be seen through discover command.
    Please let me know how to troubleshoot this problem
    Thanks

    In the array, I tried to add switch wwn to the LUN Security and zoned the same switch wwn on the MDS. Is there anything I am missing. Thanks in advance
    But still I could not see any LUNs. When I do discover command, NLUNS shows 0.
    and the command sh scsi-target lun os win shows nothing.
    discover scsi-target vsan 21 fcid 0xea000b os win
    VSAN: 21 FCID: 0xea000b
    PRLI RSP: 0x01 SPARM: 0x0012
    SCSI TYPE: 31 NLUNS: 0
    Vendor: HITACHI Model: DISK-SUBSYSTEM Rev: 5007
    Other: 7f:00:03:12:cf:00:00:02

  • The Cisco MDS 9000 Port Analyzer Adapter

    Hi,
    At my client place, we are having an issue with BackUp via TSM and a library.
    We would like to analyse the traffic that pass in the Fiber Channel of our MDS-9513.
    From what we saw, Wireshark, our soft to analyse network traffic is only using NIC card to analyse.
    Is the only way to analyse the FC traffic to pass via "The Cisco MDS 9000 Port Analyzer Adapter" ?
    If that is the only way, is there a way tor ent this equipment for the time necesery to analyse our trace ?
    Thank you in advance for you help.
    Christian Carrier

    The Cisco Traffic Analyzer provides real-time analysis of SPAN traffic or analysis of captured traffic through a Web browser user interface. Traffic encapsulated by one or more Port Analyzer Adapters can be analyzed concurrently with a single PC and ntop, which is public domain software enhanced by Cisco for Fibre Channel traffic analysis. This Cisco Traffic Analyzer solution enables you to quickly determine the throughput for traffic between specific Fibre Channel sources and destinations, all traffic in a particular Virtual SAN (VSAN), or all network traffic. Round trip response times, SCSI I/Os per second, SCSI read vs. write traffic throughput and frame counts, SCSI session status and management task information are provided. Additional statistics are also available on Fibre Channel frame sizes and network management protocols.
    For further information click this link.
    http://www.cisco.com/en/US/products/hw/ps4159/ps4358/products_data_sheet09186a0080142d34.html#wp1002317

  • Using Cisco MDS 9148 switch for switching and routing

    Hi Gurus,
    Can you please advice me! Can i configure interface trunking, routing and dhcp services on the Cisco MDS 9148 switch?
    Thanks for your response!!

    Tommy,
    MDS9148 is a Storage SAN Fibre Channel switch, it doesn't support Ethernet, IP, VLANs, VLAN trunking, 802.1Q, IP routing, DHCP. It's meant for Fibre Channel connectivity between Fibre Channel server HBAs and Fibre Channel storage.
    Roman

  • Cisco MDS port channel with USC FI

    Hello,
    Can anyone help me to configure/troubleshoot Cisco MDS 9148 with Cisco USC ? M stuck in port channel..i have configured but interfaces are not coming UP.It is showing init state.
    My Topology is like,
    Nexus 5000-->USC FI (single FI) -->Cisco MDS 9148
                                                     --> Two Chassis
    Any help would be highly appreciated...
    Thanx

    TMC-UCSFI-A-A(nxos)# sh interface brief
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc1/31     1      NP     off     errDisabled      swl    --           --
    fc1/32     1      NP     off     errDisabled      swl    --           --
    Ethernet      VLAN   Type Mode   Status  Reason                   Speed     Port
    Interface                                                                   Ch #
    Eth1/1        1      eth  fabric up      none                        10G(D) --
    Eth1/2        1      eth  fabric up      none                        10G(D) --
    Eth1/3        1      eth  fabric up      none                        10G(D) --
    Eth1/4        1      eth  fabric up      none                        10G(D) --
    Eth1/5        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/6        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/7        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/8        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/9        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/10       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/11       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/12       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/13       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/14       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/15       1      eth  trunk  up      none                        10G(D) 100
    Eth1/16       1      eth  trunk  up      none                        10G(D) 100
    Eth1/17       1      eth  fabric up      none                        10G(D) --
    Eth1/18       1      eth  fabric up      none                        10G(D) --
    Eth1/19       1      eth  fabric up      none                        10G(D) --
    Eth1/20       1      eth  fabric up      none                        10G(D) --
    Eth1/21       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/22       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/23       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/24       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/25       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/26       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/27       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/28       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/29       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/30       1      eth  access down    SFP not inserted            10G(D) --
    output ommitted
    TMC-UCSFI-A-A(nxos)#
    Here it shows that Fc1/31- 32 which are in trunk , status is errdisabled and admin trunk mode is off

Maybe you are looking for

  • Where did the Quicktime streaming server go??

    It looks as if the Quicktime streaming server is gone for good - apparently it is not part of the Lion server install, and it can't be found on the Apple web site either. There is a page for it, but it doesn't actually provide any useful information.

  • Font problem in Forms 10g

    We are upgrading an application(forms and reports) from 6i to 10g. We are testing the application from 10gDev. Suite. The forms in 6i contains certain fonts like Arial Narrow (Western),Wingdings (Western),Arial(Western),Terminal,Tahoma,Fixedsys,Times

  • Songs not showing up in each category

    I've just purchased my first iPod and I'm having some difficulties when I update the ipod with new music. I've filled out all of the information about the song (artist, album, genre, etc...) but for example, if I go to a particular artist all of thei

  • Display all the fields in one screen shot

    Hi all, I am having 20 fields in the grid. but few fields are displaying in the grid and the scroll bar is existing to display other fields where as i need all the fields in on screen shot. let me know it .

  • Root.sh script is not running successfully in RAC

    Hi when i run root.sh script for RAC Grid installation. throws below error in screen. CRS-4123: Oracle High Availability Services has been started. ohasd is starting CRS-2672: Attempting to start 'ora.gipcd' on 'rac1' CRS-2672: Attempting to start 'o