HP MDS 8/12c Fabric Switch.

hi
I have HP C7000 enclosure , with  MDS 8/12c Fabric switch. the enclosure is in production and connected directly to HP and IBM storage.
I have new 24 port Brocade switch. , what is the best solution for connecting to the new Brocade switch with minimus distruption, does the Inertop mode in that configuration supported.
regards

So Brocade will become your "core" switch ? I would look into utilizing NPIV on brocade and enabling NPV mode on MDS. Enabling NPV mode is disruptive, it will erase all configuration from the MDS switch. If your hosts are running multipathing software you should be able to do it one fabric at a time. You will need to convert your MDS zoning into Brocade zoning so when you move storage ports to Brocade and connect MDS (post NPV conversion) to Brocade ..if all zones are already in place, hosts will login to storage ports and multipathing software should re-establish the paths.

Similar Messages

  • Cisco MDS 9216i Multilayer Fabric Switch

    I have a question in regards to fibre channel over ip. this switch will allow for san traffic to flow over the wan link to a remote site, however my question would be, can this switch plug into an existing fibre channel switch (EMC Connectix) and route the traffic over the link or would the current switch need to be replaced with this device?

    Yes, think of the FCIP connection as just an ISL link abeit that it is over an IP connection. So, you are just creating a multi-switch environment. Again, it's probably not recommended to route over a FC ISL link to get to a MDS doing FCIP but also, its not the end of the world. It depends on how much the FCIP replication traffic is occuring and if you are overloading the FC ISL links. The speeds will autonegotiate to their maximum speeds and you can create portchannels to the EMC switch to consolidate bandwidth. Just turn the loadbalancing to src/dst if that emc switch is not a MDS rather than default src/dst/oxid.

  • MDS9216 & MDS9124 Fabric Switches interface stats. via SNMP

    Dear All,
    I am interested in monitoring the interface statistics (In/Out bytes) of MDS9216 & MDS9124 Fabric Switches via SNMP and have been researching on what OID (MIB) values shall i poll? Would anyone be able to help me please? I have looked at many places but the closest I could get is the IF-MIB MIB Interface which has ifTable giving ifInOctets and ifOutOctest per port !  I am not sure if this is what i am suppose to poll as the ifInOctets gives 'the total number of octets recieved on the interface' and not the traffic ? What i am interested in is knowing the traffic (rx / tx) on the port at the time of polling so i can poll them say every 5 min. and plot them via something like cacti.
    Please let me know if any one has got any suggestion as I am not getting anywhere on this.
    Thanks in advance.

    ifSpeed I see listed here :-
    http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_2_x/fabricware/mibs/reference/guide/mibiiobj.html#wp1044690
    not sure if that will give you what you need.  We use solarwinds to monitor our MDS's.

  • Cisco MDS9124 Fabric Switch

    Hi
    We want to know if we can use a DS-IBM-FC-K9 part within this Cisco MDS9124 Fabric Switch ?
    Nomi

    Hello Nomi,
    Since there has been no reply to this post, it is being moved to the data center community for better visibility.
    Thank you,
    Fabienne.

  • Upgrade MDS 9124E Fabric Switch hor HP c-Class

            Hi
    all SAN switches MDS95XX and MDS9124e24 port  must be upgraded from NX-OS 4.1.3a to NX-OS 5.2.2d
    I have no details on the process for switch HP 9124 e.
    Is it disruptif  . How many steps from 4.1.3a to 5.2.2d .
    Generally is the process the same with HP 9124e than MDS9124
    Best regards

    Hi Giles,
    Here is more info on upgrading.
    NX-OS upgrade Best Practices for MDS switches
    https://supportforums.cisco.com/docs/DOC-26029
    Near the bottom is a link to the Release Notes.
    Table 11 in the Release Notes has the upgrade path.
    Please refer to the bottom of the 9124e data sheet
    http://www.cisco.com/en/US/partner/prod/collateral/ps4159/ps6409/ps5987/product_data_sheet0900aecd805f187a.html
    Service and Support
    Level 1 and 2 support is provided by IBM and HP for their respective blade switches.
    HP Support for the 9124e
    http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp?lang=en&cc=us&prodTypeId=3709945&prodSeriesId=3355738&lang=en&cc=us
    Regards,
    David

  • Enabling VM Guest NLB w/Multicast IGMP on 2012 Hyper-V host w/ converged SCVMM fabric switch

    What a mouthful.
    As short as possible: 
    WHAT I'M ATTEMPTING:
    I'm trying to build a new NLB cluster for a 2008 R2 SP1 Remote Desktop Services farm. And I'm trying to do it the right way, with multicast igmp, not unicast. 
    The two guest VMs with NLB install converge fine. VIP gets this:
    IP: 192.168.100.157
    MAC: 01-00-5e-7f-64-9d
    NLB NIC is on the same VLAN & "Converged switch" in VMM as our mgmt/server traffic (That is to say it's on production VLAN, not on a separate vlan) 
    PROBLEM:
    Can't ping 100.157. From VM guest itself, from host, or from Cisco 6509 switch. 
    Cisco show mac address lookup does not see that MAC anywhere
    show ip igmp groups shows not igmp traffic at all. Clearing counters show sno multicast increment.
    FURTHERMORE:
    Host is setup thusly:
    - Dell R810
    - 8x1GbE Broadcom 5709c in a Server 2012 LACP/HASH team built via VMM powershell cmdlets
    - On the physical switch side, those 8 nics are in a Cisco port-channel, trunked, all VLANs allowed
    -  Host has no "physical" nics per se, as in a 2008 R2 hyper-v host. Instead Host has these:
    Set-VMNetworkAdapter -ManagementOS -Name "Live Migrate" -MinimumBandwidthWeight 35
    Set-VMNetworkAdapter -ManagementOS -Name "MGMT" -MinimumBandwidthWeight 25
    Set-VMNetworkAdapter -ManagementOS -Name "CSV" -MinimumBandwidthWeight 40
    Set-VMNetworkAdapter -ManagementOS -Name "iSCSI #1" -MinimumBandwidthWeight 0
    Set-VMNetworkAdapter -ManagementOS -Name "iSCSI #2" -MinimumBandwidthWeight 0
    Set-VMNetworkAdapter -ManagementOS -Name "Aux" -MinimumBandwidthWeight 0
    Get-VMSwitch outputs this on the converged v-switch: 
    ComputerName : My-host
    Name : My awesome switch
    Id : e2377ce3-12b4-4243-9f51-e14a21f91844
    Notes :
    SwitchType : External
    AllowManagementOS : True
    NetAdapterInterfaceDescription : Microsoft Network Adapter Multiplexor
    Driver
    AvailableVMQueues : 0
    NumberVmqAllocated : 0
    IovEnabled : False
    IovVirtualFunctionCount : 0
    IovVirtualFunctionsInUse : 0
    IovQueuePairCount : 0
    IovQueuePairsInUse : 0
    AvailableIPSecSA : 0
    NumberIPSecSAAllocated : 0
    BandwidthPercentage : 0
    BandwidthReservationMode : Weight
    DefaultFlowMinimumBandwidthAbsolute : 0
    DefaultFlowMinimumBandwidthWeight : 1
    Extensions : {Microsoft NDIS Capture, Microsoft
    Windows Filtering Platform, Microsoft
    VMM DHCPv4 Server Switch Extension}
    IovSupport : False
    IovSupportReasons : {This network adapter does not support
    SR-IOV.}
    IsDeleted : False
    Question:
    Aside from a few of my favorite MS MVPs (shout out to
    WorkingHardInIt for having this same question), I can't find much documentation on employing 2008 R2 NLB on guest VM within a fabric-oriented, VMM-built 2012 Hyper-Visor converged switch (no network virtualization...yet).
    Yes I know all about VMM NLB but 1) I'm trying to wedge NLB in after building these VMs without a service template (NLB is the audible, essentially) and 2) MS NLB is configured in providers & I've created requisite VIP templates. 
    Even so, I ought to be able to create an NLB cluster without VMM's assistance in this scenario correct? Suboptimal, I know but possible, yes? Essentially I've put to synthetic NICs on each VM, set IPs manually, and assigned them to the same vlan. I can ping
    each synthetic NIC, but not the cluster IP. 
    And yes: these particular vNICs have Mac Address Spoofing enabled. 
    Cisco:
    I have a TAC case open with Cisco, but they can't quite figure it out either. IGMP Snooping enabled across the switch. And they insist that the old static arp entry to resolve this problem is no longer necessary, that Microsoft now complies with relevant
    RFCs
    Possible SOlution:
    Only thing I can think of is flipping MulticastForwarding param below from disabled to enabled. Anybody ever tried it on a converged virtual switch on the Hyper visor? Is my virtual converged switch protecting
    me from multicast igmp packets? 
    PS C:\utilities> Get-NetIPv4Protocol
    DefaultHopLimit : 128
    NeighborCacheLimit(Entries) : 1024
    RouteCacheLimit(Entries) : 128
    ReassemblyLimit(Bytes) : 1560173184
    IcmpRedirects : Enabled
    SourceRoutingBehavior : DontForward
    DhcpMediaSense : Enabled
    MediaSenseEventLog : Disabled
    IGMPLevel : All
    IGMPVersion : Version3
    MulticastForwarding : Disabled
    GroupForwardedFragments : Disabled
    RandomizeIdentifiers : Enabled
    AddressMaskReply : Disabled
    Thanks for any thoughts. 
    Robert

    Sorry for the poor follow-up Steven. We are using Server 2012 Hyper-V, not VMWare, on the hosts. You can close this but for the benefit of anyone who comes across it: 
    After working with Cisco, we decided not to implement multicast IGMP. Cisco says you still need to create a static ARP entry on the physical switch, though my cluster IP address & Microsoft NLB 2008 R2 were set up with igmp multicast, not multicast or
    unicast. Here was his email:
    Yes, we will need the static mapping for the NLB server in this case because the NLB mac address is multicast and the IP address is unicast. I was under the impression that even the server would be using IGMP but that’s not
    the case. We won’t need to do the mapping for the nodes though if they use IGMP. To this end, following is the configuration that should make this work.rp 192.168.100.157
    0100.5e7f.649d arpa
    <u5:p></u5:p>
    mac address-table static 0000.0000.649d vlan <> interface <> disable-snooping  
    ßThis is the switch interface where the NLB server is located<u5:p></u5:p>
     interface vlan<>
    <u5:p></u5:p>
    ip pim sparse-dense-mode     <- This is needed for the switch to elicit IGMP joins from the nodes<u5:p></u5:p>
    end<u5:p></u5:p>
    I don't think it got through to him that there was a virtual Layer 2/3 Hyper-V switch on top of 8 teamed GbE interfaces in LACP/hash. "Where the NLB server is located" = 1)a Cisco port-channel bound to one of six physical hosts; the NLB VM itself could be
    on any of those port channels at any given time (We have a six node Hyper-V cluster). 
    Once I enabled pim I did see activity; but we killed this later as we realized we'd have to implement the same on 40+ managed routers globally
    Anyway we further would have had to implement this across managed routers at 40 sites globally according to Cisco. 
    Robert

  • Satellite R840-12C: cannot switch off the WiFi function manually

    I have recently purchased a brand new Toshiba Satellite R840-12C Notebook.
    The Wifi LED remains "on" and the function key does not work, in other words cannot switch off the WiFi function manually.
    Although the WiFi function remains 'on" I cannot connect to a wireless modem.
    When I go to device manager I find conflicts in "other devices" for
    1. Network Controller
    2. PCI Simple Communications Controller
    3. Unknown Device
    Tried updating drivers by connecting through ethernet cable to the modem but to no avail.
    Can someone help?

    Hi
    Did you install the WLan driver?
    The notebook seems to be equipped with the Atheros AR9285 Wlan card and in most cases the Fn + F8 button does not work because the Wlan driver is not installed or does not work properly.
    Recommend firstly deleting the WLan card from the device manager and then to reboot the notebook. After the new reboot install the new downloaded Atheros Wlan driver for this wlan card.
    Here you can find all the Wlan drivers published by Toshiba:
    http://aps2.toshiba-tro.de/wlan/?page=downloads

  • Deploying agent 12c - Invalid switch - "oracle"

    Hello,
    My OMS is OEM 12c BP1, host OMS is AIX5.3.
    Deploying OEM Agent 12c on several Windows 2003SP2 remote servers, most of them successfully.
    But on one of them, it returns an error that puzzle me.
    In D:\oracle\product\agent12c\ADATMP_2012-08-30_08-19-52-AM\logs\install.err, I can read :
    Invalid switch - "oracle".The log In D:\oracle\product\agent12c\ADATMP_2012-08-30_08-19-52-AM\logs\install.log is
    D:\oracle\product\agent12c\ADATMP_2012-08-30_08-19-52-AM
    Present working directory:D:\oracle\product\agent12c\ADATMP_2012-08-30_08-19-52-AM
    Archive location:D:\oracle\product\agent12c\ADATMP_2012-08-30_08-19-52-AM  directory
    -ignorePrereqs
    ORACLE_HOSTNAME
    ORACLE_HOSTNAME
    myagenthost.mydomain.com
    AGENT_BASE_DIR
    AGENT_BASE_DIR
    D:/oracle/product/agent12c
    Agent base directory:D:/oracle/product/agent12c
    D:/oracle/product/agent12c
    OMS_HOST
    OMS_HOST
    myomshost.mydomain.com
    OMS Host:myomshost.mydomain.com
    myomshost.mydomain.com
    EM_UPLOAD_PORT
    1159
    AGENT_INSTANCE_HOME
    D:/oracle/product/agent12c/agent_inst
    b_doDiscovery
    false
    b_startAgent
    false
    b_forceInstCheck
    true
    AGENT_PORT
    3872
    Agent base directory:D:/oracle/product/agent12c
    OMS Host:myomshost.mydomain.com
    Agent image loc : "D:\oracle\product\agent12c\ADATMP_2012-08-30_08-19-52-AM"
    D:/oracle/product/agent12c configonlyfalse
    Reading the properties file: "D:\oracle\product\agent12c\ADATMP_2012-08-30_08-19-52-AM"\agentimage.properties
            1 file(s) copied.
    This is the version 12.1.0.1.0
    This is the type core
    This is the aru id 912And the log on the OMS host for this Agent deployment is
    2012-08-30_08-31-21:INFO:=========STACKTRACEPrinting Exception :oracle.sysman.prov.remoteinterfaces.exception.ClusterException: Error while running cmd D:/oracle/product/agent12c
    /ADATMP_2012-08-30_08-19-52-AM/agentDeploy.bat, on nodes myagenthost.mydomain.com.
            at oracle.sysman.prov.remoteinterfaces.nativesystem.NativeSystem.runCmdOnNodes(NativeSystem.java:1260)
            at oracle.sysman.prov.remoteinterfaces.clusterops.ClusterBaseOps.runCmdOnNode(ClusterBaseOps.java:263)
            at oracle.sysman.core.agentpush.ui.deployer.DeployerOps.executeCmdOnNode(DeployerOps.java:510)
            at oracle.sysman.core.agentpush.ui.deployer.DeployerOps.executeCmdOnNode(DeployerOps.java:496)
            at oracle.sysman.core.agentpush.ui.deployer.BaseDeployerOps.doInstall(BaseDeployerOps.java:330)
            at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
            at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:60)
            at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:37)
            at java.lang.reflect.Method.invoke(Method.java:611)
            at oracle.sysman.core.agentpush.ui.deployer.BaseDeployerOps.executeActions(BaseDeployerOps.java:1732)
            at oracle.sysman.core.agentpush.ui.deployer.NewAgentDeployer.deploy(NewAgentDeployer.java:58)
            at oracle.sysman.core.agentpush.ui.deployfwk.DeploymentWorker.run(DeploymentWorker.java:26)
            at oracle.sysman.util.threadPoolManager.WorkerThread.run(Worker.java:264)
    oracle.sysman.prov.remoteinterfaces.exception.CommandException: The command "'D:/oracle/product/agent12c/ADATMP_2012-08-30_08-19-52-AM/agentDeploy.bat' -ignorePrereqs  ORACLE_HOS
    TNAME=myagenthost.mydomain.com  AGENT_BASE_DIR=D:/oracle/product/agent12c  OMS_HOST=myomshost.mydomain.com  EM_UPLOAD_PORT=1159  AGENT_INSTANCE_HOME=D:/oracle/product/agen
    t12c/agent_inst  b_doDiscovery=false  b_startAgent=false  b_forceInstCheck=true  AGENT_PORT=3872  2>D:/oracle/product/agent12c/ADATMP_2012-08-30_08-19-52-AM/logs/install.err  1>D
    :/oracle/product/agent12c/ADATMP_2012-08-30_08-19-52-AM/logs/install.log" was not run.
            at oracle.sysman.prov.remoteinterfaces.plugins.RemoteCommandJSCH.runcmd(RemoteCommandJSCH.java:213)
            at oracle.sysman.prov.remoteinterfaces.nativesystem.RemoteExecutionEngine.runcmd(RemoteExecutionEngine.java:417)
            at oracle.sysman.prov.remoteinterfaces.nativesystem.NativeSystem.runcmd(NativeSystem.java:5463)
            at oracle.sysman.prov.remoteinterfaces.nativesystem.WindowsSystem.runCmd(WindowsSystem.java:1662)
            at oracle.sysman.prov.remoteinterfaces.nativesystem.NativeSystem.runCmd(NativeSystem.java:4455)
            at oracle.sysman.prov.remoteinterfaces.nativesystem.NativeSystem.runCmdOnNodes(NativeSystem.java:1234)
            at oracle.sysman.prov.remoteinterfaces.clusterops.ClusterBaseOps.runCmdOnNode(ClusterBaseOps.java:263)
            at oracle.sysman.core.agentpush.ui.deployer.DeployerOps.executeCmdOnNode(DeployerOps.java:510)
            at oracle.sysman.core.agentpush.ui.deployer.DeployerOps.executeCmdOnNode(DeployerOps.java:496)
            at oracle.sysman.core.agentpush.ui.deployer.BaseDeployerOps.doInstall(BaseDeployerOps.java:330)
            at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
            at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:60)
            at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:37)
            at java.lang.reflect.Method.invoke(Method.java:611)
            at oracle.sysman.core.agentpush.ui.deployer.BaseDeployerOps.executeActions(BaseDeployerOps.java:1732)
            at oracle.sysman.core.agentpush.ui.deployer.NewAgentDeployer.deploy(NewAgentDeployer.java:58)
            at oracle.sysman.core.agentpush.ui.deployfwk.DeploymentWorker.run(DeploymentWorker.java:26)
            at oracle.sysman.util.threadPoolManager.WorkerThread.run(Worker.java:264)
    ============It's also complaining that the error message cannot be found.
    I think I followed the same way to deploy Agent on this server than I did on other where it was successfully done. So, probably some configuration is different somewhere on the server itself which has to be checked and changed. Any idea ?
    Nicolas.

    Thank you for stopping by.
    Akanksha wrote:
    Is this locked avvount usecases that you are trying ?For example, you can create a named credential titled User_A, and set it to run as User_X that has the root privileges. In this case, the wizard logs in to the hosts as User_A, but installs as User_X.I really do not understand what you mean here. I have maybe 20 remote Windows server (all Windows 2003 SP2) which I deployed the Agent on, and 3 are failing even though I did exactly the same over all the servers.
    2 are returning the error below :
    Parameter format not correct - "ppl".
    The syntax of the command is incorrect.1 is returning the error I described in my first post. I sent you the files for that last one by email since this is the one I started to talk about in that thread.
    And yes, I agree, probably something specific on those 3 servers which I have to figure out.
    Thanks,
    Nicolas.

  • Interconnecting MDS 9148 with 2 different Fiber Providers

    Hi
    I would like discuss the following issue :
    We have 2 HP SAN EVA 8400 ( one at the production site and one at our Disaster Recovery site ) replicating using a fiber channel service from ( 2* FC dark fiber from PROVIDER A )
    They are linked together  with 4 Cisco MDS 9148 Multilayer Fabric Switch (2 fabric ). 
    We have recently purchased a new fiber service ( 2* 1Gb FC managed service from PROVIDER B) in order to create a port channel  with the 2 running ones and we have some problem.
    We disconnected the PROVIDER A FC ( running for 10 years now )  and left the SAN replication during a couple of days running with the new PROVIDER B 1 Gb FC to make sure the link was stable and we had no issue.
    Then we tried to connect the 2 FC together from the 2 providers and tried to create a Port channel.
    However we discovered that to create a PortChannel, interfaces must have the same configurations ( speed, mode, rate )
    In our case , the interface FC 1/1 using PROVIDER A link is running at 4 Gb and the interface FC 1/2 using PROVIDER B is running at 1 Gb
    PROVIDER A dark fiber
    PROVIDER B fiber managed service
    fc1/1 is trunking
        Hardware is Fibre Channel, SFP is CWDM-1550
        Port WWN is 20:01:00:05:9b:72:b1:60
        Peer port WWN is 20:01:00:05:9b:72:b1:a0
        Admin port mode is E, trunk mode is on
        snmp link state traps are enabled
        Port mode is TE
        Port vsan is 1
        Speed is 4 Gbps
        Rate mode is dedicated
        Transmit B2B Credit is 32
        Receive B2B Credit is 32
        B2B State Change Number is 14
        Receive data field Size is 2112
        Beacon is turned off
        Trunk vsans (admin allowed and active) (1)
        Trunk vsans (up)                       (1)
        Trunk vsans (isolated)                 ()
        Trunk vsans (initializing)             ()
        5 minutes input rate 4416 bits/sec, 552 bytes/sec, 6 frames/sec
        5 minutes output rate 91616 bits/sec, 11452 bytes/sec, 11 frames/sec
          51537358280 frames input, 50955393731852 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          223256095067 frames output, 408667816663528 bytes
            32 discards, 0 errors
          34 input OLS, 36 LRR, 51 NOS, 0 loop inits
          53 output OLS, 35 LRR, 45 NOS, 0 loop inits
          32 receive B2B credit remaining
          32 transmit B2B credit remaining
          28 low priority transmit B2B credit remaining
        Interface last changed at Fri Dec 14 17:02:48 2012
    fc1/2 is trunking
        Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
        Port WWN is 20:02:00:05:9b:72:b1:60
        Peer port WWN is 20:02:00:05:9b:72:b1:a0
        Admin port mode is E, trunk mode is on
        snmp link state traps are enabled
        Port mode is TE
        Port vsan is 1
        Speed is 1 Gbps
        Rate mode is dedicated
        Transmit B2B Credit is 32
        Receive B2B Credit is 32
        B2B State Change Number is 14
        Receive data field Size is 2112
        Beacon is turned off
        Trunk vsans (admin allowed and active) (1)
        Trunk vsans (up)                       (1)
        Trunk vsans (isolated)                 ()
        Trunk vsans (initializing)             ()
        5 minutes input rate 48 bits/sec, 6 bytes/sec, 0 frames/sec
        5 minutes output rate 48 bits/sec, 6 bytes/sec, 0 frames/sec
          39496053 frames input, 2696451760 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          167653989 frames output, 230540944084 bytes
            70 discards, 0 errors
          40377 input OLS, 345 LRR, 4248 NOS, 0 loop inits
          5186 output OLS, 1154 LRR, 39568 NOS, 0 loop inits
          32 receive B2B credit remaining
          32 transmit B2B credit remaining
          28 low priority transmit B2B credit remaining
        Interface last changed at Fri Dec 14 16:50:42 2012
    So we tried to force the FC 1/1 to run at 1 Gb ( same speed as FC 1/2 ) to create the PortChannel, by doing the basic command on the interface : Switchport speed 1000
    Since that , our SAN is logging every 10/15 minutes the following errors :
    ---------- Problem Found: CUST: CA informational: EVA8400_LIVE: Write resources on the inter site link have been reduced. at Fri 14 Dec 2012 17:21:04 GMT+01:00 ----------
    ---------- Problem Found: CUST: CA warning: EVA8400_DR: Excessive out of order message rate on the inter site link. at Fri 14 Dec 2012 17:27:04 GMT+01:00 ----------
    ---------- Problem Found: CUST: CA warning: EVA8400_DR: Excessive data exchange retry rate on the inter site link. at Fri 14 Dec 2012 17:41:34 GMT+01:00 ----------
    ---------- Problem Found: CUST: CA warning: EVA8400_LIVE: Excessive data exchange retry rate on the inter site link. at Fri 14 Dec 2012 17:41:49 GMT+01:00 ----------
    We have the following questions :
    Have you already seen that kind of situation ?
    Is there a best practice  to reduce the interface speed in order to create the PortChannel with identical interface setup ?
    Your help and advice would be much appreciated.
    Regards

    the RTT delay by each link is different and this is causing packets to arrive out of order.
    not sure if port channeling between two different links or different characteristics is good practive.

  • Cisco MDS 9148 Inventory Collection

    Hi
    I get the following error on an inventory collection of a MDS 9148 (NOS 5.0.4). I have tried deleting and recreating the device.
    RME 4.3.1
    RICS0001:Internal Error,unable to process the collected data from the device.
    [ Thu Dec 30  13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.LibInventory.PortInterfaceAGI_RFC1213_HelperMethods,getIfTableEntriesFromDevice,759,Entry speed after if block: 1000000000 Index value : 101191680
    [ Thu Dec 30  13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,58,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:populating AssetAG attributes, begins...
    [ Thu Dec 30  13:48:53 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,57,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,64,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:AssetAG Collection aborted com.cisco.nm.xms.xdi.ags.system.CollectionFailedDeviceSensed: java.lang.ArrayIndexOutOfBoundsException: 5 >= 5
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,549,DP time is 20 seconds for 172.23.32.129
    [ Thu Dec 30  13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor,458,
    java.lang.NullPointerException
    at com.cisco.nm.rmeng.inventory.ics.invdata.containment.ContainmentAGInvData.compare(ContainmentAGInvData.java:103)
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processContainmentAG(InvDataProcessor.java:864)
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:330)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
    at java.lang.Thread.run(Thread.java:595)
    [ Thu Dec 30  13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,935, Exception occured in process method while processing: 172.23.32.129 null
    ICSException
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:473)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
    at java.lang.Thread.run(Thread.java:595)
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1191,No Trap
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1203,CALLING SELF TEST
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1207,DONE WITH SELF TEST

    Hi Naem,
    have just read the othre reply's, the intresting bit it is in the MDF.
    - <DEVICE NAME="Cisco  MDS 9148 Multilayer Fabric Switch" MDFID="282867260" CISCOMDFID="282867260">
    <SYSOID OID="1.3.6.1.4.1.9.12.3.1.3.841" NAME="OID:1.3.6.1.4.1.9.12.3.1.3.841" />
    The device adds ok, I just can not run an Inventory but can run a backup !
    Thanks

  • UCS Basic Questions

    Hi
    I am new to Cisco UCS, I have a little idea about Nexus Series Switches.
    I would like to know what exactly are the differentiating factors between -
    UCS 6100 Fabric Interconnect
    Nexus 5000 Series
    MDS 9000 Series switches
    All these can support FCoE, 1G / 10G Ports, I know 6100 Fabric Interconnect has built in UCS Manager
    where I can place these in a real worl solution.
    Second -
    Can we make multiple Blades in a chassis, or Multiple Blades in Multiple Chassis conected to a Single / Multiple interconnected 6100 Fabric Interconnect / Nexus / MDS switch, to combine as a Single / One Server.
    Appreciate your kind response.
    Tahnks & Regards
    Sunny

    Sunny,
    I hope the beow information helps clarify present questions and future knowledge you might get in the near future.
    All the information is taken form the link that follows: 
    http://www.cisco.com/en/US/docs/solutions/Enterprise/Data_Center/VMDC/2.0/design_guide/archOver.html
    Cisco Nexus 5000
    The Cisco Nexus 5000 Series  (http://www.cisco.com/en/US/products/ps9670/index.html) switches deliver  high performance, standards-based Ethernet and FCoE that enable the  consolidation of LAN, SAN, and cluster network environments onto a  single Unified Fabric. Each switch contains a single unified crossbar  fabric ASIC and multiple unified port controllers to support fixed ports  and expansion modules.
    Cisco UCS and UCSM
    Cisco UCS 6100 Series Fabric Interconnects (http://www.cisco.com/en/US/partner/products/ps10276/index.html) is a family of line-rate, low-latency, lossless, 10-Gbps Ethernet and Fibre Channel over Ethernet interconnect switches.
    Cisco UCS 5100 Series Blade Server Chassis (http://www.cisco.com/en/US/partner/products/ps10279/index.html) supports up to eight blade servers and up to two fabric extenders in a six rack unit (RU) enclosure.
    Cisco MDS 9513
    The Cisco MDS 9513 Multilayer Director allows you to deploy  high-performance SANs using a high-performance, protocol-independent  switch fabric. It provides uncompromising high availability, security,  scalability, ease of management, and transparent integration of new  technologies for extremely flexible data center SAN solutions. The Cisco  MDS 9513 is compatible with first-, second-, and third-generation Cisco  MDS 9000 Family switching modules.
    For more information, see: http://www.cisco.com/en/US/products/hw/ps4159/index.html.
    Cisco MDS 9134
    The Cisco MDS 9134 Multilayer Fabric Switch is a 1RU chassis that  provides line-rate 4-Gbps and 10-Gbps ports. It expands from 24 to 32  ports in 8-port increments and optionally activates 2 10-Gbps ports. The  Cisco MDS 9134 offers non-blocking architecture, with all 32 4-Gbps  ports and the 2 10-Gbps ports operating at line rate concurrently.
    The 10-Gbps ports support a range of optics for connection to the Cisco  MDS 9000 family core using 10-Gbps Inter-Switch Link (ISL) connectivity.  The Cisco MDS 9134 can also be stacked using copper CX4 X2 transceivers  to cost effectively offer up to 64-port densities. The Cisco MDS 9134  supports quick configuration and task wizards that allow it to be  deployed quickly and easily in networks of any size. Powered by Cisco  MDS 9000 NX-OS/SAN-OS Software, it includes advanced storage networking  features and functions and is compatible with Cisco MDS 9500 Series  Multilayer Directors and Cisco MDS 9200 Series Multilayer Fabric  Switches, providing transparent, end-to-end service delivery in  core-edge deployments.
    For more information, see: http://www.cisco.com/en/US/products/hw/ps4159/index.html.
    Cisco MDS 9148
    The Cisco MDS 9148 Multilayer Fabric Switch is a one rack unit (1RU)  top-of-rack (ToR) chassis that provides 48 line-rate 8-Gbps ports for  storage networking deployments. It can expand from 16 to 48 ports in  8-port increments. The Cisco MDS 9148 delivers a non-blocking  architecture, with all 48 1/2/4/8-Gbps ports operating at line-rate  concurrently.
    The Cisco MDS 9148 supports the Cisco Device Manager Quick Configuration  Wizard, which allows it to be deployed quickly and easily in networks  of any size. Powered by Cisco MDS 9000 NX-OS Software, it includes  advanced storage networking features and functions and is compatible  with Cisco MDS 9500 Series Multilayer Directors and Cisco MDS 9200 and  other 9100 Series Multilayer Fabric Switches, providing transparent,  end-to-end service delivery in core-edge deployments.
    For more information, see: http://www.cisco.com/en/US/products/hw/ps4159/index.html.
    PS:  If you find it helpful, please mark it with a 5 stars grade!
    -Kenny

  • MDS FC Blade Switch for IBM - Licensing

    Hi,
    our customer has got installed the 20-port-switch of the "Cisco MDS Fibre Channel Blade Switch for IBM BladeCenter". He wants to change some of the links now. For that reason he asked me:
    - Is there a fix relationship between a port and a license?
    - Can we use any port as long as we fall below the number of licenses?
    Thanks in advance and regards
    Matthias

    Hello Matthias,
    Cisco Fabric Switch for IBM BladeCenter (20 ports; 14 internal 2/4 Gbps, and 6 external full-rate ports) licenses for internal ports are allocated as the ports come up. Licenses for external ports are allocated sequentially.
    Refer "On-Demand Port Licensing" section on CLI guide here :
    http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_3_x/configuration/guides/cli_3_3/ondport.html
    Customer can select the specific external ports he wants licensed.
    switch# config t
    switch(config)# interface fc1/1
    switch(config-if)#port-license acquire
    Thanks,
    Prateek

  • Fabric Interconnect To MDS 9148 FC Port Channel/Trunks

    Is it possible to create both a Port Channel and Trunk on a Cisco MDS 9148? Yes correct?
    Or can I only trunk between the 2 MDS switches and not the MDS to Fabric Interconnect?
    These FC links would be connected to a 2248XP Fabric Interconnect carrying multiple VSANs from the MDS to the Fabric Interconnect.
    Thanks

    Hello,
    Yes, you can have trunk links grouped into port channel ( F port-channel trunking ) between FI and MDS.
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_0101.html
    Padma

  • Add MDS switch so other MDS switches can see vsan

    We have 2 Cisco MDS 9148's (main production), one of the 9148's is setup for vsan 10 and the other is setup for vsan 20. We have a 3rd MDS 9124 (isolated used for a backup setup), that has vsan 30 on figured on it. We would like to connect the two MDS 9148's to the MDS 9124 so the MDS 9148's can see vsan 30.
    Regards

    2 MDS 9148 represent Fabric A and Fabric B ? If yes you don't want to connect 9124 to both of them as you will cause fabrics to merge ..and that defeats the purpose of isolating fabrics for redundancy.
    @dynamoxxx

  • Configuring Radius server with Cisco MDS - 9606 switch

    Need help in configuring Radius server with cisco MDS - 9606
    please let me know if any document available

    rtt min/avg/max/mdev = 0.260/0.327/0.468/0.077 ms
    IFCBCCEMCSW2# sh version
    Cisco Storage Area Networking Operating System (SAN-OS) Software
    TAC support: http://www.cisco.com/tac
    Copyright (c) 2002-2008, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained herein are owned by
    other third parties and are used and distributed under license.
    Some parts of this software may be covered under the GNU Public
    License or the GNU Lesser General Public License. A copy of
    each such license is available at
    http://www.gnu.org/licenses/gpl.html and
    http://www.gnu.org/licenses/lgpl.html
    Software
    BIOS: version 1.1.0
    loader: version 1.2(2)
    kickstart: version 3.3(1c)
    system: version 3.3(1c)
    BIOS compile time: 10/24/03
    kickstart image file is: bootflash:/m9500-sf1ek9-kickstart-mz.3.3.1c.bin
    kickstart compile time: 5/23/2008 19:00:00 [06/19/2008 23:56:56]
    system image file is: bootflash:/m9500-sf1ek9-mz.3.3.1c.bin
    system compile time: 5/23/2008 19:00:00 [06/20/2008 00:26:51]
    Hardware
    cisco MDS 9506 ("Supervisor/Fabric-1")
    Intel(R) Pentium(R) III CPU with 1028596 kB of memory.
    Processor Board ID JAB094300ER
    bootflash: 250368 kB
    slot0: 0 kB

Maybe you are looking for

  • How to Delete an iCloud Account's Email (Not the Whole Account, Just the Email)

    Hello, A couple of years ago, before iCloud was iCloud and was actually MobileMe, I created my own email on it (an @me.com email) and have had it ever since. Even after it became iCloud, i've kept my @me.com email address and have it to this day. I'v

  • Automatically Running a Java Program

    I have a Java program which converts a text file to a XML file. I would like to be able to automatically run this program once every 8 hours or to have it run at set times. Has anybody done this before or does anybody know how to do this?

  • Different stylesheets in the one web template

    does anyone know the best way to use different stylesheets for different tables in the one web template?

  • Run a procedure

    Hello all I try to run procedure that I wrote. It compile but it just doesn't affect my database. it's supposed to delete all the users that have the same name but different ID and leave only the one that have the min ID I wrote this procedure in T-S

  • Back Ground Results

    Hi, I have to do syntax checks for all types of programs, I have sheduled the Back Ground job, I have seen the log it says the Job i9s finished,can I see the results of my program ?