HP ProLiant Micro Server

Just bought a 
HP 704941-421 ProLiant Micro Server (AMD Turion II Neo N54L 2.2GHz, 2GB RAM, 250GB HDD, 2 Core, 7th ...
Manual says check out the latest BIOS
I have now spent 2 hours going around in circles trying (a) to register my product and (b) to check and download if necessary the BIOS.  To say the site is cumbersome is to be polite!  The S/N isn't recognised The model name doesn't appear
The BIOS installed is: ID: 041 VER: 07/29/2011
Can anyone tell me if it is up-to-date and where I can go to download an update?
Thanks

Hi:
You may also want to post your question on the HP Business Support Forum -- DL Servers section...
http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/bd-p/itrc-264#.U_OAQjh0zGg

Similar Messages

  • Win 8.1 install on HP ProLiant ML10 server

    If i want to install win 8.1 proff on HP ProLiant ML10 server ( xeon 3.1 ghz processor ) so it can work or not ???????
    Please help .....

    Hi,
    For ProLiant ML10, we can get following information in this link:
    http://www.windowsservercatalog.com/item.aspx?idItem=3d94ac2f-058b-25af-7225-f6119e3c25f9&bCatID=1282
    Regarding to install Windows 8.1, please refer to
    System requirement of Windows 8.1, and then check if HP ProLiant ML10 server meets all system requirement of Windows 8.1.
    In addition, I suggest that you can post the question in
    Windows 8.1 forum, or contact with your hardware vendor to confirm this issue.
    Hope this helps.
    Best regards,
    Justin Gu

  • Compaq Proliant 1600 Server Install

    Hi!
    I'm working on setting up a Compaq Proliant 1600 server. . .I've made a bit of progress thanks to a few posts on the forum.
    I've bugged everyone on the irc channel so now its time to ask here  :oops:
    Basically, I can't get the Arch install to recognize the scsi drives (2) I've got...
    What I've done:
    1.  Loaded all the modules (cpqarray etc...)
    2.  In '/dev' I did 'mkdir ida'
    3.  Next I 'mknod /dev/ida/c0d0p1 b 72 1' <---this should be my swap
    4.  Then I 'mknod /dev/ida/c0d0p2 b 72 2' <-----this is my /
    Now I'm not sure what to do...
    Since I've been able to partition the drives the next step seems to be to
    set filesystem mountpoints, right?  The Arch install doesn't recognize  the drives at all - It simply says "NONE". 
    So, if anyone has any tips or advice I'd appreciate it 
    I'm setting this server up for my school's website - and thought I'd go with Arch. . .
    Thanks!
    nedson

    It's all about loading the right modules. With < 0.7 ISO's you can modprobe cpqarray. Later ISO's don't have cpqarray anymore, they use cciss.
    Some threads you'll want to read:
    Help no cpqarray modules
    Compaq proliant install help

  • Windows OS required for hp proliant ml10 server machine

    Dear / Sir
    I planned to buy a new server machine which is a hp proliant ml10
    so my query is  whch operating systems i can legally install on it.
    any legel windows operating systems or only windows server edidtion.
    Thanking you
    nitin

    Hi,
    You can found your server model is certificated with Windows Server or not in Windows Server Catalog website:
    ProLiant ML10
    by Hewlett-Packard Company
    Compatible with   the following versions of Microsoft Windows
    Windows Server 2012 R2 x64
    Certified for Windows
    Windows Server 2012 x64
    Certified for Windows
    Windows Server 2008 R2 x64
    Certified for Windows
    Windows Server 2008 x64
    Certified for Windows
    But the ProlLiant
    ML10 have many extension model, personal advice is you can ask your hardware vendor for the further help.
    The related third party information:
    HP ProLiant ML10 Server
    http://www8.hp.com/us/en/products/proliant-servers/product-detail.html?oid=5390723#!tab%3Dmodels
    More information:
    Windows Server Catalog
    http://www.windowsservercatalog.com/item.aspx?idItem=3d94ac2f-058b-25af-7225-f6119e3c25f9&bCatID=1282
    Hope this helps.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • HBA card suitable for HP ProLiant DL380G7 Server

    Hello, please i need the part number of a suitable HBA card preferrably 8GB double port for HP Proliant DL380G7 server to connect fibre cables

    Hi:
    You may also want to post your question on the HP Business Support Forum -- DL Servers section.
    http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/bd-p/itrc-264#.U3N63elOW9I

  • HP Proliant ML350G4 server - problem with array

    Hi, I have HP Proliant ML350 G4 server. The problem is that I can not configure the array for SCSI hard drives. When I run the Array Configuration Utility from the SmartStart CD, I get the message: "ACU did not detect any supported controllers in your system." How do I solve this problem?

    Hi:
    You may also want to post your question on the HP Business Support Forum -- ML Servers section.
    http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/bd-p/itrc-264#.U48mculOW9I

  • Proliant 3000 Server Mod

    Would it be possible to remove and replace the motherboard from a Compaq Proliant 3000, intended for business use? Also, if the key to the door is lost, what can be done about that?
    Thanks...

    Thanks for reply
    I've added read access to developer directory:
    drwxr--r-x 11 developer users 4096 03-18 21:03 developer
    Nothing changed.
    error_log
    [Tue Mar 18 22:42:47.462658 2014] [authz_core:error] [pid 2150:tid 2941197120] [client 192.168.1.100:56103] AH01630: client denied by server configuration: /home/developer/public_html
    No idea how "public_html" get there?!
    access_log
    192.168.1.100 - - [18/Mar/2014:22:38:34 +0100] "GET /~developer HTTP/1.1" 403 1081
    192.168.1.100 - - [18/Mar/2014:22:38:45 +0100] "GET /~developer/www HTTP/1.1" 403 1081
    192.168.1.100 - - [18/Mar/2014:22:42:47 +0100] "GET /~developer/www HTTP/1.1" 403 1081
    192.168.1.100 - - [18/Mar/2014:22:42:47 +0100] "GET /favicon.ico HTTP/1.1" 404 1099
    192.168.1.100 - - [18/Mar/2014:22:42:47 +0100] "GET /favicon.ico HTTP/1.1" 404 1099
    EDIT
    Ok, I've found the solution for that. In file httpd-userdir.conf UserDir was "public_html" instead of "www".
    Now I'm getting error 500
    error_log
    [Tue Mar 18 22:48:36.841443 2014] [mpm_event:notice] [pid 2803:tid 3074947456] AH00489: Apache/2.4.7 (Unix) mod_python/3.5.0- Python/3.3.5 configured -- resuming normal operations
    [Tue Mar 18 22:48:36.841528 2014] [core:notice] [pid 2803:tid 3074947456] AH00094: Command line: '/usr/bin/httpd'
    [Tue Mar 18 22:48:45.873329 2014] [:error] [pid 2805:tid 3033516864] make_obcallback: could not import mod_python.apache.\n
    [Tue Mar 18 22:48:45.874559 2014] [:error] [pid 2805:tid 3033516864] make_obcallback: Python path being used "['/usr/lib/python33.zip', '/usr/lib/python3.3', '/usr/lib/python3.3/plat-linux', '/usr/lib/python3.3/lib-dynload', '/usr/lib/python3.3/site-packages']".
    [Tue Mar 18 22:48:45.874589 2014] [:error] [pid 2805:tid 3033516864] get_interpreter: no interpreter callback found.
    [Tue Mar 18 22:48:45.874612 2014] [:error] [pid 2805:tid 3033516864] [client 192.168.1.100:56122] python_handler: Can't get/create interpreter., referer: http://192.168.1.108/~developer/
    Last edited by maci3k (2014-03-18 22:37:32)

  • [SOLVED] Console screen garbled installing to HP Proliant ML10 server

    Hi,
    We have bought a new HP proliant ML10 for replacing the machine that is being used as the main server of our school and running debian-edu / skolelinux.
    Considering the cutting edge software and etc benefits of arch, I'm planning to setup dual boot the main server with skolelinux for current use and arch alongside. I can experiment with arch in the time when no one uses the server/clients (night time). My plan is to setup arch to server diskless clients and do a migration from debian-edu / skolelinux. This seems ok to me from security standpoint as we used to have all MS win machines with no firewall at all before we migrated everything to linux a few months back.
    Now to the problem,
    While using the latest dual USB arch install media, I do get an initial root console but it is looking diagonal and totally garbled, hard to read.
    here is the lspci output obtained by booting the HP server as diskless from our old debian server
    root@auto-mac-9c-b6-54-af-6e-7a:/skole/tjener/home0/uday# lspci
    00:00.0 Host bridge: Intel Corporation Xeon E3-1200 v2/Ivy Bridge DRAM Controller (rev 09)
    00:1a.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 (rev 05)
    00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5)
    00:1c.4 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 5 (rev b5)
    00:1c.6 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 7 (rev b5)
    00:1c.7 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 8 (rev b5)
    00:1d.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 (rev 05)
    00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev a5)
    00:1f.0 ISA bridge: Intel Corporation C204 Chipset Family LPC Controller (rev 05)
    00:1f.2 SATA controller: Intel Corporation 6 Series/C200 Series Chipset Family SATA AHCI Controller (rev 05)
    01:00.0 System peripheral: Hewlett-Packard Company Integrated Lights-Out Standard Slave Instrumentation & System Support (rev 05)
    01:00.1 VGA compatible controller: Matrox Electronics Systems Ltd. MGA G200EH
    01:00.2 System peripheral: Hewlett-Packard Company Integrated Lights-Out Standard Management Processor Support and Messaging (rev 05)
    01:00.4 USB controller: Hewlett-Packard Company Integrated Lights-Out Standard Virtual USB Controller (rev 02)
    02:00.0 Ethernet controller: Intel Corporation 82574L Gigabit Network Connection
    0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 02)
    0d:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 02)
    The default screen resolution is 1366 X 768
    I think that's all what I can provide.
    Thanks
    Last edited by cyberbandya (2015-04-18 01:21:33)

    Adding
    nomodeset vga=791
    to kernel parameters of install media solves the issue
    Reference
    https://wiki.archlinux.org/index.php/Intel_graphics
    https://wiki.archlinux.org/index.php/Ke … de_setting
    Thanks
    UDAY
    Last edited by cyberbandya (2015-04-18 01:19:57)

  • HP Proliant ML360 Server: How hard would it be to install Windows 2012 R2 on an older server like this one?

    Hello,
    I am an it tech in need of some help. I don't mess with our servers that often, and I could use some guidance in setting up this particular machine. We would like to use this server with 2012 R2 for Michigan M-step caching machine, and possibly setting up
    a ticket system for maintenance, and technology repairs. This server was configured before I got here, and I would like to delete the current novell software and Server 2003, and start over fresh. Is there a manual that you could recommend, or a step by step
    instruction guide that will show me the correct steps to take. I have watched youtube videos, read different articles, however they really didn't give me the information that I am looking for to set up this server. Any help you can give me would be greatly
    appreciated!!
    Thank you,
    Angie

    The very first thing you need to determine is if the ML360 is a 32-bit or 64-bit server.  If it is 32-bit, it's a no-go.  Windows Server 2012 is 64-bit only.
    The next issue is installation media.  Does the ML360 have a DVD or CD reader?  2012 R2 comes on DVD.  It's possible to install from USB, but that's if the system supports it.  Does the ML360 support booting from USB?
    Yes, the smart start capability is neat, but it is generally geared to a specific release of an operating system for a server that supports that operating system.  The ML 360 is old enough that smart start may not work on it.
    I would go out to HP.com and download all the latest drivers for the ML360 and put those on a CD.  I would also get the latest BIOS/Firmware.  Make sure the system is updated to the latest BIOS/Firmware.
    Before trying to give any further suggestions, it would help to know exactly what you have.
    . : | : . : | : . tim
    Tim -- all HP ML360s support 64-bit architecture. That was the first Series HP released full x64 bit architecture support. (I'm an HP Accredited Platform Specialist)
    I agree with the other points however.
    Entrepreneur, Strategic Technical Advisor, and Sr. Consulting Engineer - Strategic Services and Solutions Check out my book - Powershell 3.0 - WMI: http://amzn.to/1BnjOmo | Mastering PowerShell Coming in April 2015!

  • HTTP.SYS fails to load after ProLiant NIC driver update on Server 2008 R2

    Hi team,
    This has been driving me crazy for a week and I can't find any reference to solving the problem in Technet or any forums...
    I have a ProLiant ML350G5 server that I installed Server 2008 R2 on and migrated all my domain AD, DNS, File Services, Shares and files from SBS2003 (end of life, so let's take that out of the network) - Exchange and SharePoint were not being used so Standard
    server 2008 was the choice seeing that the server hardware is 4 years old...
    Everything went well, migration was successful, AD was primary and active.
    Then (stupidly) I decided I'd better install all the updated drivers and management software from HP. The NIC is showing as an HP NC373i which is a Broadcom BCM5708C. I updated the FLASH in that card (HP utility) and updated the driver to the latest version
    7.8.52.0 along with a bunch of other updates all handled by HP's Support Solutions Framework (msi).
    After the reboot required, I noticed that the Print Spooler (set to Automatic) didn't start, neither did IIS or Web Services...
    Trying to manually start them gives the error that a dependency failed. Now Print Spooler only uses HTTP (no longer a "service" but integrated into the kernel for multiple http connections on the same port and controlled using netsh http command
    prompt...) DCOM and RPC. The last 2 are running, so that leaves HTTP as the culprit.
    The Event Log shows that HTTP failed to load as "the services cannot be started. Either because it is disabled or because
    it has no enabled devices associated with it"
    From an administrator cmd prompt, net start http gives the same failure error.
    netsh http show servicestate returns "The handle is invalid" - it's not seeing http at all...
    OK. If you've read this far, thank you - keep going...
    Here's my thinking... Updating the NIC driver has "broken" the association with HTTP.SYS - How to I get that association back?
    I uninstalled anything http related, IIS, BITS, Web, Printing Services. Reboot after reboot and still no HTTP. I deleted http.sys from \windows\system32\drivers and did sfc to get windows to give me a clean one. Reboot, still doesn't load so it's not a damaged
    http.sys.
    I uninstalled EVERYTHING ProLiant, uninstalled the NIC, deleted the bxnd60a.sys driver so Windows would use it's own, rebooted, let it load NIC drivers, set the IP's up again, reboot - still no http.sys loading...
    I've tried older versions of drivers from Broadcom, the latest version of drivers, still in the same hole...
    Does anyone know how I can get HTTP.SYS to associate with the NIC? Can I do anything in the registry to achieve this? Do I have to do a System State Backup (is that the only way to preserve the AD and DNS?) scrub the server and start from scratch and then
    restore the System State to get my AD and DNS back? If I do that will it bring the http.sys fault back?
    I'm really at a loss - please, someone, please help...

    Hi team,
    This has been driving me crazy for a week and I can't find any reference to solving the problem in Technet or any forums...
    I have a ProLiant ML350G5 server that I installed Server 2008 R2 on and migrated all my domain AD, DNS, File Services, Shares and files from SBS2003 (end of life, so let's take that out of the network) - Exchange and SharePoint were not being used so Standard
    server 2008 was the choice seeing that the server hardware is 4 years old...
    Everything went well, migration was successful, AD was primary and active.
    Then (stupidly) I decided I'd better install all the updated drivers and management software from HP. The NIC is showing as an HP NC373i which is a Broadcom BCM5708C. I updated the FLASH in that card (HP utility) and updated the driver to the latest version
    7.8.52.0 along with a bunch of other updates all handled by HP's Support Solutions Framework (msi).
    After the reboot required, I noticed that the Print Spooler (set to Automatic) didn't start, neither did IIS or Web Services...
    Trying to manually start them gives the error that a dependency failed. Now Print Spooler only uses HTTP (no longer a "service" but integrated into the kernel for multiple http connections on the same port and controlled using netsh http command prompt...)
    DCOM and RPC. The last 2 are running, so that leaves HTTP as the culprit.
    The Event Log shows that HTTP failed to load as "the services cannot be started. Either because it is disabled or because it has no enabled devices
    associated with it"
    From an administrator cmd prompt, net start http gives the same failure error.
    netsh http show servicestate returns "The handle is invalid" - it's not seeing http at all...
    OK. If you've read this far, thank you - keep going...
    Here's my thinking... Updating the NIC driver has "broken" the association with HTTP.SYS - How to I get that association back?
    I uninstalled anything http related, IIS, BITS, Web, Printing Services. Reboot after reboot and still no HTTP. I deleted http.sys from \windows\system32\drivers and did sfc to get windows to give me a clean one. Reboot, still doesn't load so it's not a damaged
    http.sys.
    I uninstalled EVERYTHING ProLiant, uninstalled the NIC, deleted the bxnd60a.sys driver so Windows would use it's own, rebooted, let it load NIC drivers, set the IP's up again, reboot - still no http.sys loading...
    I've tried older versions of drivers from Broadcom, the latest version of drivers, still in the same hole...
    Does anyone know how I can get HTTP.SYS to associate with the NIC? Can I do anything in the registry to achieve this? Do I have to do a System State Backup (is that the only way to preserve the AD and DNS?) scrub the server and start from scratch and then restore
    the System State to get my AD and DNS back? If I do that will it bring the http.sys fault back?
    I'm really at a loss - please, someone, please help...

  • HP BL Proliant Server

    Hello All,
    Often HP Proliant BL Server gets restarted, We could find the error in IML Log that "Disk Array is not configured"
    What will be the possible solutions?
    Thanks in Advance.

    Hi:
    You may also want to post your question on the HP Business Support Forum - Proliant Servers section.
    http://h30499.www3.hp.com/t5/ProLiant/ct-p/prolian​t

  • Lan card that support server proliant

    I have a HP ProLiant DL380pG8 server-107 and HP ProLiant DL380eG8-666,my question is : a10 Gb lan card support for these servers?Thank you

    Hi:
    You may also want to post your question on the HP Business Support Forum -- DL Servers section.
    http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/bd-p/itrc-264#.U4NRUelOW9I

  • DL380 SmartStart Deploy Server "Continue" button not working

    Howdy.
    We currently have an older Proliant DL380 server that we would like to set up and use SME Server  (Redhat Linux) on. 
    When attempting to install the software, the server comes up and says "Set to Windows 2000" and tries to boot off of the A: and C: drives.   I did recall having to use the SmartStart CD for other servers and have set up this OS on them and assumed it would require the same.  I downloaded the latest version of the SmartStart software (x86 and x64), but when it's trying to load it tells me that the i686 architecture is not supported by either of those versions.
    After a bit of research I found that somebody had been using v8.15 and downloaded and burnt that version to CD.  It allows me to go into the SmartStart setup utility and reboot to see the RBSU and ORCA and lets me access the raid via ACU.  However, when attempting to click "Continue" to progress to the installation of the operating system, nothing happens.  No windows or messages appear.
    Is there a different version of this tool I should be using or something that will allow me to change the boot from Windows mode to Linux mode?
    Thanks in advance.
    Trevor Watson

    Hi Vimukta,
    Little late in replying to your post. I tried to generate the PDF using the same XDP template sent by you.
    It is working perfectly fine for me. 
    Can you please verify the code you have written on the WDDoModifyView method ? Just check the form element name once again.
    I know you might have done it but just double check on this.
    //@@end
    public static void wdDoModifyView(IPrivateCreateView wdThis, IPrivateCreateView.IContextNode wdContext, com.sap.tc.webdynpro.progmodel.api.IWDView view, boolean firstTime)
        //@@begin wdDoModifyView
    if(firstTime){
       IWDInteractiveForm iForm = (IWDInteractiveForm)view.getElement("InteractiveForm1");
       iForm.setDynamicPDF(true);
        //@@end
    Step to debug :
    1. Try in another desktop, try to access the same URL where you have adobe reader 8.1 is installed.
    2. Just create one sample PDF with 2/3 fields and try to hide those fields on click of checkbox throgh java script. let me know if that is working or not.
    3. May be you have problem with the "ReaderRights" Please check your Adobe credentials.
    Actually i have tried with WebAS versiion 7.0 SP10.
    I just think there is mnor problem with ADS configuration.
    Cheers
    Satya

  • Arch install on Compaq Server

    I am in need of a good os for my Compaq Proliant 3000 server and was thinking about Arch.  Has anyone tried this?  Basically, does Arch have all the necessary modules for a compaq array controller and raid5 support? 
    Please let me know your experiences.

    um, this isn't really the place for that kind of question, it would probably get more attention under kernel/hardware issues. You might wanna get it moved by a forum admin.

  • How's this partition table for my server?

    How's this partition table for my server?  Web/DNS/DHCP/Mail Server.
    hdd1: ~8gb total
    /boot - 100mb
    swap - 1gb
    / - rest of drive
    hdd2: ~155gb total
    /var - whole drive
    This is a Compaq ProLiant 5500 server with 10 drives.  Will most things be installed inside /var or what?

    Zetsumei wrote:Web/DNS/DHCP/Mail Server.
    Web = /srv
    DNS = /var
    DHCP = /var
    Mail = Depends which package you use. I use postfix and told it to use /srv
    I would half your swap, reduce /var and put the extra space into /srv
    Also create a separate /tmp and /home to prevent accidental or deliberate DoS attacks by filling your / partition
    Here's what I use on my Web / DNS / FTP server:
    Filesystem Size Used Avail Use% Mounted on
    /dev/xvda 493M 176M 317M 36% /
    /dev/xvdc 31M 674K 29M 3% /boot
    /dev/lvmData-home 62M 26M 34M 44% /home
    /dev/lvmData-usr 2.0G 848M 1.1G 45% /usr
    /dev/lvmData-tmp 496M 20M 451M 5% /tmp
    /dev/lvmData-srv 1.5G 769M 667M 54% /srv
    /dev/lvmData-var 496M 231M 241M 49% /var
    /dev/lvmData-pacman 384M 303M 82M 79% /var/cache/pacman
    /dev/lvmData-backup 5.5G 4.6G 565M 90% /mnt/backup

Maybe you are looking for

  • Search box not displaying correctly in Safari

    How can the search bar on the Apple site not display correctly in Safari? I find this odd that Apple would allow this. It displays like 2 search boxes overlapping each other. It still functions correctly but it is a little embarrassing since I am alw

  • My users cannot see my java applets

    I have a few java applets on my web page, but most of the users cannot see them. I have changed my html's with the HTML Converter, hoping to overcome the problem, and got the following codes in my html's: In the <OBJECT> tag: http://java.sun.com/prod

  • Suggestion for fixing broken raid set

    Jesus. Again. Twice in 6 months. Raid set failure. 2:58pm today : Drive 3:50014ee2aede46eb missing - Previous drive status was inuse 2:59pm today : Degraded RAID set RS1 2:59pm today : Degraded RAID set RS1 - No spare available for rebuild Jesus... A

  • AIX 5.3 ML3 에 9.2.0.6 patch 시 에러가 나네요..

    error in writing to file 1. /oracle/lib/libvpxoafnd.so 2. /oracle/lib/libxdb.so 3. /oracle/lib/libwtc9.so 4. /oracle/lib/libvppdc.so 5. /oracle/lib/libjox9.a 6. /oracle/lib32/libclntsh.a 7. error in invoking target 'install' of makefile /oracle/netwo

  • How to see data records of idoc?

    Hi Can anybody tell me how can i see the data records of idoc.. i think its stored in EDID4 table..but i am not able to see the sdata field