I am getting noise clusters in differential mode for ground refeenced source

I am using DAQ board PCI-MIO-16E-1 and 2090 BNC as termination accessory. I want to aquire data from a ground referenced source.I am getting a lots of shot noise which is having a peiodic envope of 55 Hz frequency .These clusters are never removed in all the three modes but the strange thing is that i am having better results in RSE mode than in differential mode for the same source.This looks like a conflicting obervation from what is recomended.What may be the source for these peiodic noise clusters which are unavoidable.
One clue is that we get the same signal if we acquire data between our source ground and earth and same is the case for our computer.This noise is not removed ev
en if we short grounds of PC and our ground reference source.
Attaced is the file having the picture of noise i get.
Attachments:
noise_pic.bmp ‏231 KB

Hello;
Noise is a difficult issue to advise about.
There are some things you can try, but the result will depend on different factors, such as, environment, lenght of cables, equipment on vicinity, etc.
Anyways, you can try to hook up a BIAS resistor in between the ch- and AIGND on your BNC device. That resistor will bleed out the common voltage current and help on noise balancing. Another thing you can try is to hook up a simple RC low pass filter at the analog input. That might help to get rid of that noise.
I'm also attaching an App Note that talks about Noise and some ways to get around it.
Hope this helps.
Filipe A.
Applications Engineer
National Instruments
Attachments:
Field_Wiring_and_Noise_Considerations.zip ‏196 KB

Similar Messages

  • Unable to get the data in RSA 3 for the data source 2LIS_03_BX.

    Hi Xperts,
    we are loading the data sources(2LIS_03_BX) by using MCNB transaction but not getting the data in it.
    can any one please tell me how to load the data into it with step by step process.
    regards,
    satish

    Hi,
    To see the data in RSA3 you need to do the setup of data for the particular data source through SBIW transaction.
    The Rsa3 transaction displays the data present in the setup tables of the particular data source.

  • Separate blend mode for each clone source

    If each clone source could have it's own blend mode (not to mention its own opacity and hardness) setting it would be more effective. The current blend mode setting in the clone source affects the preview only.
    I often have to jump back and forth between Normal, Lighten, and Darken modes, and would like the convenience of clicking between sources already set to what I want.
    Thanks

    What goes on in the new "Clone Source Panel" is unrelated to Tool Presets oddly. It would be possible, to optionally allow recording of the settings in the Panel, as part of the Clone Tool Presets. But they never bothered to do it. Its as if this feature was designed with no understanding of the importance of Tool Presets at all. This would solve your problem.
    The shortcut for Lighten Darken and Normal are Alt > Shift > G, K and N, respectively. This may speed up your work.

  • How can I change the daq setting to differential mode in my labview program (example)?

    I would appreciate if I could get an example in Labview 5.1. I realized that I need to create a cluster but for some reason it would not work

    Examples for data acquisition are in the LabVIEW >> Examples >> Daq >> anlogin >> anlogin.llb directory. You will still have to do the following to programmatically set the measurement mode to differential.
    You can set your data acquisition with the AI Config.vi in LabVIEW. There is an input for "coupling and input config". A good trick to make sure that you create the cluster correctly is to use your mouse as the wiring tool and right-click over that input. Then, choose Create Control or Create Constant. The cluster will pop up, and you can use your operating tool to choose differential mode for the second pull-down ring in the cluster.
    Geneva L.
    Applications Engineering
    National Instruments
    http://www.ni.com/ask

  • Problem of shift of groud level in AI channel in Differential mode ?

    We are using PXI-6052E card ,
    When checking Analog Input of the card in the Differential mode ,
    The ground level shifts by about 1.11 Volt .
    * When we applied +Ve 5 Volt from the Analog output channel 0 to the AI channel 0 it
    gives us 6.11 Volt ( -5.0 +1.11 = 6.11 ) in average in MAX .
    * When we applied -Ve 5 Volt from the Analog output channel 0 to the AI channel 0 it
    gives us -3.88 Volt ( -5.0 + 1.11 = -3.88) in average in MAX .
    * When we applied +Ve 3 Volt from the an external battery to the AI channel 0 it
    gives us 4.38 Volt ( 3.00 + 1.11 = 4.38) in average in MAX .
    * When we applied +Ve 3 Volt from the an external battery to the AI channel 0 with
    the inputs reversed it gives us -1.89 Volt( -3.00 + 1.11 = -1.89) in average in MAX .
    * When we applied 5 Volt(peak to peak) from the Analog output channel 0 to the AI
    channel 0 it gives us 6.11 Volt ( -5.0 +1.11 = 6.11) average in MAX for +Ve peak
    value and -3.88 Volt ( -5.0 + 1.11 = -3.88) in average in MAX for –Ve peak value .
    It gives the same results for all 8 DI Analog channels .
    What can be the possible solutions for our problem ?
    Do the card need calibration or some other problem is there ?

    Greetings,
    I would first suggest that, if this device is in a system connected to the internet, you run the Online E Series Diagnostic. This utility will test the functionality of your board and perform a self-calibration. The link to this utility is available below:
    http://ni.com/support/selftest/
    Unless this calibration fixes the problem, I would create a phone support request at the following location to arrange the repair of your board:
    http://sine.ni.com/apps/we/niae_asc.main
    Best.
    Spencer S.

  • Windows Server 2012 The licensing mode for the Remote Desktop Session Host server is not configured

    Hi
    I have a standard Windows Server 2012 that is hosted in the cloud by a hosting provider -
    This server has been up and running fir 6 months - recently we have been getting a warning
    "The licensing mode for the Remote Desktop Session Host server is not configured" - The Remote Desktop Session Host server is within its grace period, but the RD Session Host server has not been configured with any license server.
    Yet, we only use this with 2 connections as part of the standard licence agreement and this server is not used as a user's desktop only an ftp and web server- do therefore we do not need to purchase any cal licences (we have another server with the same
    hosting company that does not have this issue and has been up for 18months)
    Please can someone advise how I resolve this issue, the hosting company states that I must resolve it as they only host and resell the server licence
    Thank-you
    Richard Steele

    Hi Richard,
    You need to uninstall Remote desktop session host feature. After removing it, you will default two connections which does not need to purchase RD CALs'.
    Thanks,
    Umesh.S.K

  • Differential mode of PXI

    I'm using PXI-4461 based on Visual Basic programming. My goal is to generate 
    differential mode signal with 0.5v offset using the PXI-4461 and VB.
    The followings are details, but I'm attaching a ppt file for better understanding of my question.
    How can I shift up the negative sinewave by +1v?
    The following is the VB code which is the same as the code in the attached ppt file.
    Public Sub test(ByVal numSamples As Long, ByRef writeData() As Double, dataRate As Double)
         If chanDAQ.taskHandle <> 0 Then
            DAQmxErrChkMod DAQmxTaskControl(chanDAQ.taskHandle, DAQmx_Val_Task_Unreserve)
            DAQmxErrChkMod DAQmxStopTask(chanDAQ.taskHandle)
            DAQmxErrChkMod DAQmxCfgSampClkTiming(chanDAQ.taskHandle, "", dataRate, DAQmx_Val_Rising, DAQmx_Val_AcquisitionType_ContSamps, numSamples)
            DAQmxErrChkMod DAQmxWriteAnalogF64(chanDAQ.taskHandle, numSamples, False, 10#, DAQmx_Val_GroupByChannel, writeData(0), sampsPerChanWritten, ByVal 0&)
            DAQmxErrChkMod DAQmxStartTask(chanDAQ.taskHandle)
            chanDAQ.taskStarted = True
        End If
    End Sub 
    <Description to explain the same problem descripbed in the attached ppt file.> 
    PXI-4461 is connected to an oscilloscope with BNC cable. 4461 uses the differencial mode (NOT pseudo-differential mode)
    due to some reason. The positive signal from 4461 (i.e. the center core of BNC) is connected
    to channel 1 of the oscilloscope, and the negative signal (i.e. the shield of BNC) is connected to
    channel 2.
    Then A sinewave which has the range from 0 to 2v and 1v offset, was generated in VB program.
    Then it was applied to an oscilloscope. The channel 1 of oscilloscope showed a sinewave which has
    the range from 0 to 1v with 0.5v offset, and the channel 2 showed a sine which has the range
    from -1v to 0v with -0.5v offset.
    For my application, the channel 1 is ok,  but channel 2 should be shift up by 1v, basically the channel 2
    should be a sine which has the range from 0v to +1v and +0.5v offset, and also its phase should lead
    over 180 degree.
    Message Edited by talking on 05-03-2010 09:27 PM
    Attachments:
    question1.ppt ‏153 KB

    Thank you very very much, Adam.
    Let me answer to your questions first.
    >it might be best to get the signal working in Measurement and Automation Explorer.
    Yes, I have just tried to use MAX. But results are the same as one that I got using my VB code.
    But it was good suggestion. I think using task in MAX is powerful.
    >I imagine you are splitting the BNC to a 2 wire pair, and then putting that 2 wire pair into another BNC cable for each channel.  Is this true?
    Yes, Correct. I followed the direction from the following document.
    www.ni.com/pdf/manuals/373088a.pdf  (page 2-13, 3-3 and 3-5)
    Only one BNC cable was used to make connection between a signle channel of PXI-4461 and two channels of oscilloscope.
    One side of the BNC was connected to a singla channel of 4461, and then the other side of the BNC was connected to two channels of oscilloscope. As shown in page 3-3 of the following document, "+" of BNC (which means positive signal of differential mode) was connected channel 1 prober of the oscilloscipe, and "-" of BNC was connected to the channel 2 prober of oscilloscope.
    Then the ground of these two probers are shared to the ground of the 4461 as shown in page 3-5.
    Is this connection of the ground correct? Please let me know anythin wrong in my setup.
    > Is there a reason that you have to split the BNC output to 2 channels?
    Yes, I need the specific reason of it. I'm working on ADC test.
    My first goal is to generate the differential mode sinewave signal from PXI-4461.
    Then the second goal is to connect this differential signal to my differetial input ADC.
    The ADC has a specification that both of positive and negative signals have 0.5v offset, and their max
    voltage is 1v, and min voltage is 0v, as I showed in the ppt fiile.
    So I need to first both of positivie and negative signal from 4461 on the scope. Then I can apply this signal to my ADC.
    The oscilloscope is not a product dedicated for differential mode signal. This is regular one (agilent DSO5034A).
    > From my recollection a scope should expect a positive signal, and a ground or negative signal to the BNC, which the analog output will provide. 
    It sounds like my scope (agilent DSO5034A) might measure wrong value for offset. Isn't there any way to measure each sigle signal of differential analog signal of 4461, using my scope?
    > are you using AC or DC coupling on the o-scope?
    Yes, I was using DC coupling on the scope.
    > ensure that the signal is zero'd out correctly on the vertical scale.
    Yes, I carefully observed each signal using "cursor" from the screen of my scope.
    I'm for sure, the positive signal offset was +0.5v, and the negative offset was -0.5v as shown in my ppt file.
    Thanks.
    talking

  • PCI-1409 in differential mode

    Hello all,
    I'm using PCI-1409 for non-standard analogue video acquisition.
    My video image has a noise band which moves from below to top in the frame.
    I'm wondering my PCI-1409 is not working in the differential mode.
    How can I set this to differential mode?
    Any response will be deeply appreciated.
    Regards

    CRSmania,
    If you take a look at the PXI/PCI 1409 user manual, on page 3-5 it says
    VIDEO0±: VIDEO0± supports RSE connection only. To operate in RSE mode, you must
    connect VIDEO0– to DGND. When you use VIDEO0+ or VIDEO0–, you must
    disconnect the BNC connector.
    VIDEO<3..1>±: VIDEO<3..1>± allows for a DIFF or RSE connection to video channels
    1, 2, and 3. To operate in RSE mode, connect VIDEO<3..1>– to DGND.
    Use VIDEO 1,2 and/or 3 if you want to set PCI-1409 to be a differential mode.
    Thank you,
    Ryota Koshimizu
    NIJ AE

  • Differential mode

    Hi:
    I read the tutorial. http://zone.ni.com/devzone/conceptd.nsf/webmain/177A8B29FEDC0F5886256FA90083C0F8.
    for differential mode.
    I am measuring a DC voltage and my test fixture is a very low impendance. So I should only use AI- to AIGND to setup differential mode.
    The question I need to ask is I don't need to put any wire from AI+ to AIGND. Is this correct?
    The second question is if I then add a BNC cable from my test fixture to 5112 board. the voltage starting changing from 758ohm to 18kohm resistor. The voltage seems starting going down. I don't understand why it is happening like this. Could you explain to me? Attached is my graph.
    The third question is I use DMM to test the current from AI- to AIGND, AI- to the negative node of 100ohm and AI+ to the postive node 0f 100ohm. I got 0mA, 0mA and 0mA. I also got no voltage across 10kohm resistor.  Could you please tell me why?
    If so, how does it remove common mode voltage and noise in this config? I don't understand. Could you pls explain to me?
    I would appreicate if you can reply to me promply. I am in a very urgent.

    Attachments:
    Graph17.JPG ‏32 KB

  • Every time I start iTunes I get the message: "iTunes exec has been set to run in compatability mode for an older version of Windows. Turn off compatability mode for iTunes before you open it." How do I turn off the compatability mode?

    Every time I start iTunes I get the message: "iTunes exec has been set to run in compatability mode for an older version of Windows. Turn off compatability mode for iTunes before you open it." How do I turn off the compatability mode? Particularly when I have to do it before I turn on iTunes.

    Try the following document, only be sure that none of the boxes in the compatibility mode tab are checked (not just the compatibility mode box itself):
    iTunes for Windows: How to turn off Compatibility Mode

  • After upgrading to Yosemite under sleep mode for few hrs battery is getting discharged fully.

    System information
    Mac book Pro 13 inch Retina  Early 2013
    Processor  - 2.6 GHz Intel Core i5
    Memory - 8 GB 1600 MHz DDR3
    Graphics - Intel HD Graphics 4000 1024 MB
    Storage capacity - 500 GB
    OSX - 10.10
    Ever since I have upgraded from Mavericks to Yosemite - battery consumption has increased.
    and MOST CRUCIAL ISSUE IS - under sleep mode battery is getting drained like anything ...
    for eg - I had 70% charge last night and it got completely drained when I got up in the morning.
    there was no charge left in the battery after 6 hrs under sleep mode and it is happening for last 5 days every night...
    I have already tried various things as troubleshooting....
    Apple hardware test.
    SMC
    emptying caches etc....
    observing activity monitor and finding any program taking more energy etc... (nothing is found)..
      L3 Cache: 3 MB
      Memory: 8 G

    UPDATE: Resolved!
    Disabled all login items but problem persisted on normal boot. Resetting SMC and PRAM had no effect. After booting into Safe Boot, problem did not exist. Looked in console logs and saw this right as problem started to occur:
    10/20/14 6:49:07.004 PM com.apple.xpc.launchd[1]: (com.gspy.MO3V2Daemon[93967]) Could not find and/or execute program specified by service: 2: No such file or directory: /Library/MO3V2/MO3V2Daemon.app/Contents/MacOS/MO3V2Daemon
    This pertains to the Steelseries WoW MMO gaming mouse. Ran the uninstall.command from Applications for this mouse software and rebooted. Fixed.
    Light on MagSafe connector is orange, battery shows as charging, fan is not running constantly. I can't begin to understand how this would effect the battery charging functions but, after uninstalling this, the problem was resolved. Hope this will help someone else.

  • I tried to update my ipod touch software update by syncing with itunes and now its in recovery mode?  Is it possible to get it out of recovery mode?  if so, then how?

    I tried to update my ipod touch software by syncing with itunes and it put the ipod into "recovery mode".  Seems like the only option is to restore?  Is there a way to get it out of recovery mode?

    No.
    Once the Device is asking to be Restored with iTunes... it is too late to save anything...
    To minimise loss... Connect to iTunes on the computer you Usually Sync with and Restore from the most recent Backup...
    http://support.apple.com/kb/HT1414
    Restore from Backup
    http://support.apple.com/kb/ht1766

  • TS1369 my "home" computer for my ipad is no longer working, how can i get my ipad recognized on new comp to get it out of recovery mode?

    The original laptop i used to start my ipad broke so i have a new laptop. I cannot upgrade my ipad with the new laptop and i cannot get it out of recovery mode cuz my laptop is not recognizing the ipad. How can i get my laptop to recognize the ipad so i can get it out of recovery mode?

    Hey Dpcupcake,
    If you can not get past the sign in screen on your iPad, you will need to use the steps in this article to recover use of your iPad -
    Forgot passcode for your iPhone, iPad, or iPod touch, or your device is disabled - Apple Support
    Thanks for using Apple Support Communities.
    Happy computing,
    Brett L 

  • My iPhone 3GS 16gb, is stuck in restore mode, downloaded and tried to do a restore multiple times. Keep getting an error The iPhone "iPhone" could not be restored. Unknown error occured (-1). Cannot get it out of restore mode, keeps rebooting!

    My iPhone 3GS 16gb, is stuck in restore mode, downloaded and tried to do a restore multiple times. Keep getting an error The iPhone "iPhone" could not be restored. Unknown error occured (-1). Cannot get it out of restore mode, keeps rebooting!
    I have tried to hold the "home" and "power" button to reboot
    I have tried powering it off
    I have tried, to unplug the cable, hold the "home" button and then plug it in.
    Can't check the SN or warranty, cause it is stuck in restore mode.
    Is the hard drive gone? Should there be something replaced.

    http://support.apple.com/kb/TS3694#error1
    Error 1 or -1
    This may indicate a hardware issue with your device. Follow Troubleshooting security software issues, and restore your device on a different known-good computer. If the errors persist on another computer, the device may need service.
    Usually this is caused by your antivirus or firewall blocking iTunes access to the Internet. It can also occur if the phone is jailbroken or if the computer you are using was ever used to jailbreak an iDevice.

  • My macbook pro will not boot. It gets the grey screen with the apple until the bar is half way across and then shuts down. The only screen I can get to is in safe mode and I don't know what to do with that

    my macbook pro will not boot. It gets the grey screen with the apple until the bar is half way across and then shuts down. The only screen I can get to is in safe mode and I don't know what to do with that

    Mac OS X: Gray screen appears during startup - Apple Support

Maybe you are looking for

  • How to undo "This solved my question" on this Using iPhone forum?

    How to undo "This solved my question" on this "Using iPhone" forum? new to this forum... how do you undo this?

  • HELP: Trying to get my music from external hard drive onto *new* computer

    HELP US! Our motherboard died last month, BUT we had everything on an external hard drive (YEAH!) so we've been able to download iTunes on our new laptop, but now are having trouble getting all of my music from my iTunes library into my iPod Nano. Sp

  • HT1369 Ipod Sync Issue

    My ipod G3 will only sync purchased music and not my library or playlists. Any ideas as I have tried just about everything inc; resettingi ipod, reinstalling itunes (reboot etc) divice connectivity tests, keeps saying there is no device. Help please,

  • New Problem creating a desktop shortcut to photoshop 2014 causes the program to break?

    After getting fed up of waiting for adobe CC to finally finish buffering I thought I'd create a desktop shortcut to Photoshop (To save time). After doing this I doubled clicked on the shortcut and after 15 minutes of waiting I realized something was

  • ESS Links not working

    Hi All, I have deployed the ESS 600 SP 11and PCUIGP 600 SP 11 on EP 7 SP 11 system with the backend as ECC 6.0. Now I am getting the ESS overview and other pages with the links. But when I click on any link its not taking me anywhere. To make the lin