Dear Rob,
Although your post's date is old but I would share my knowledge for whom has the same issue.
Last day I had the same problem and could not find any solution on internet so I had to trace the code. Fortunately I managed to fix the problem My colleagues had extended an IDOC by a segment but after that the segment was deleted so I was getting an error in ALE.
Issue comes "DATA_SELECT_FOR_BLOCK" method which is using I_DOC_DATA table that fills in PFAL transaction. thru running PFAL IDOC data reads from table T777D.
Go into and find the related record and clear it
By the way after that I found http://scn.sap.com/thread/3322338 useful
Cheers,
Omid

Similar Messages

  • Table extension for compression successful (Message no. 00999)

    Dear All,
    Can you please anyone describe in more details about this problem?  We are getting this problem very occasioanly and am not getting any clue...this idoc type has Z segments
    Table extension for compression successful
    Message no. 00999
    Diagnosis
    self-explanatory
    Regards,
    Ramki.

    Dear all,
    Any updates on this...kindly please
    Rgds,
    Ramki.

  • One of the IDOCs has an specific error message (status 51 Idoc not posted)

    Dear Experts,
    ple. provide the solution for my issue.
    In my list of compaines one of the company had an external partner(warehouse) who takes care of their products.
    Communication between that external partner software and my system(PVS) is happen through IDOCs.
    But one of the IDOCs has an specific error message ( status 51 and status text : Specification for units and quantites containe error),
    acctually we are receiving picking meterials from the external system to my system.
    I can able to see the Inbound Idoc and status, I am not able to see the Outbound Idoc, then how can I test why its happening this problem and I how can I give the analysis properly please suggest me.
    Thanks in advance
    Suresh

    Suresh,
    Welcome to SDN. Adding to Jürgen Comment, Just double click on status 51 (at node), then in next screen there will be one information (long text) button, just click on it. Some times it will give good details about the error. the information can also suggest direct trasaction to correct the customization, some times!
    try for ur case.
    Reddy

  • Previously posted troubleshooting doesn't work for my error message "iTunes could not back up the iPhone because an error occurred".  What other options do I have?

    Previously posted troubleshooting doesn't work for my error message "iTunes could not back up the iPhone because an error occured".  What other options do I have to backup my iPhone data properly?

    Hi there kchagape,
    You may find the troubleshooting steps in the article below helpful.
    iOS: Troubleshooting backup issues in iTunes
    http://support.apple.com/kb/ts2529
    -Griff W. 

  • Need a BADI for raising error messages for equi update (IE02)

    Hi,
    we are trying to raise few error messages while creating equipments through BADI's (Processing through IE02 and BAPI's).
    No BADI's are supporting for raising error messages.
    SAP doesnt support processing of userexits through BAPI's (refer note 564467).
    we actually need to implement these checks and should available for all the below processes:
    Through IE02
    while doing through BAPI's
    While Executing MASS CHANGE functionality (IE05)
    Please suggest any other solution to achieve all the three at one go instead of creating some enhancements for every thing.
    thanks.

    Hi,
    Try and search for a BADI....for transaction I102...take the package name and go to SE18 and see if BADI's are available...
    Alternatively search for key CL_EXITHANDLER or get BADI in the main program of IE02..
    if you are using SAP ECC6.0 then implicit or explicit enhancements will be available... Utilize them to meet your requirement...
    Thanks

  • Mac: couldn't complete update for Ps error message 49 in Creative Cloud

    Mac: couldn't complete update for Ps error message 49 in Creative Cloud. Anyone help?

    A chat session where an agent may remotely look inside your computer may help
    Creative Cloud chat support (all Creative Cloud customer service issues)
    http://helpx.adobe.com/x-productkb/global/service-ccm.html

  • How to select a locale for parser error messages

    Does anybody know how I can select a locale for parser error messages? I found org.xml.sax.Parser.setLocale, but that's for SAX1 and deprecated.
    I have a textarea in the user interface where a user can edit XML and, of course, I'd like the parsing error messages to appear in the selected locale...
    Any help appreciated.
    - Michael

    Yes, but doing this you changed the locale for the JVM! I know that. My intention was to see whether the parsers even had error messages in languages other than English. If they didn't then there would be no point in proceeding. But they do, so maybe there is some point.
    However you don't get to specify the locale for exceptions thrown by other Java classes, so I wouldn't be surprised to find you don't get to specify the locale for exceptions thrown by XML parsers. I'm not saying there is no way to do that, only that I would not be surprised if there were no way.

  • Why do I always have "Insufficent Content for Edit" error message ?

    Hi all FCE experts,
    May I ask why do I always have "Insufficent Content for Edit" error message when I tried to overwrite or replace a clip ?
    Ok,this is what happen:
    I have a clip A (4 secs) followed by clip B (4 secs). Then in between I add a video transition.
    After a while, I reckon I want to change clip B with another clip (say clip C). So, I went to brower & search for clip C which is 2 mins long clip. To make sure there are enough handles, I went to the centre mark an In point then 4 sec later mark an Out point. So I drag this clips C of 4 secs from the Viewer (I marked the In & Out point in the viewer) to the Overlay canvas & do an Overwrite but it says "Insufficent Content for Edit".
    I then tried Replace also got the "Insufficent Content for Edit" error message.
    I then tried to delete the video transition and repeat the above for overwrite and replace, both times I got the same error.
    Any ideas ?
    Thanks

    Tom Wolsky wrote:
    From your description there is no way either of these things should happen. Without seeing it I would guess there is something else going in your timeline or your clip which you're not telling us. *Perhaps there are I/O pints marked in the timeline*. Or the destination tracks are not set correctly. or something else.
    Thanks Tom, you are correct.
    I have In Point & Out Point marked on the Timeline. I used it when I did FILE > EXPORT and left it there. But once I cleared it, I am able to replace it with another clip.
    But I am still puzzled as to why I cannot do any overwrite or replace when there is I/O points marked on the Timeline ? Especially when the section of clips I wanted to overwrite or replaced are located outside of the I/O points ?
    Thanks

  • No Matching Connection for ICMP Error Message

    I am running into a little bit of an issue with my Clean Access Deployment. We are using a pair of 5520s in conjunction with Clean Access deployed in L3 gateway mode. My active ASA is constantly displaying the message "No Matching Connection for ICMP Error Message source Clean Access Manager destination some client on our VPN subnet." I understand during discovery the Clean Access Agent will ping the Manager, however what I can't understand is why the CAM continues to send ICMP unreachable messages to some clients. It may send hundreds of these messages over a period of two or three minutes. Any ideas?

    I am running into a little bit of an issue with my Clean Access Deployment. We are using a pair of 5520s in conjunction with Clean Access deployed in L3 gateway mode. My active ASA is constantly displaying the message "No Matching Connection for ICMP Error Message source Clean Access Manager destination some client on our VPN subnet." I understand during discovery the Clean Access Agent will ping the Manager, however what I can't understand is why the CAM continues to send ICMP unreachable messages to some clients. It may send hundreds of these messages over a period of two or three minutes. Any ideas?

  • When I download a theme or other extension file to my desktop and try installing it, it tells me this: The jar file "foxscape-3.04-fx.jar" couldn't be launched. Check the Console for possible error messages. What's the issue?

    Regardeless of the file name, I get the same message:
    The jar file "NAME OF FILE-fx.jar" couldn't be launched. Check the Console for possible error messages

    Although possibly not related to your problem, I have to remind you that the version of Firefox you are using at the moment has been discontinued and is no longer supported. On top of this, it has known unpatched bugs and security problems. I urge you to update to the latest version of Firefox, for maximum security, stability, performance and usability. You can get it for free, as always, at [http://www.getfirefox.com getfirefox.com].

  • Error message on updates for CS6, error message on updates for CS6

    I've been having major issues with CS6 as well as CC - started with both versions of photoshop locking up, then totally refusing to open. Uninstalled both versions, just reinstalled CS6 but it is not opening unless I hit the shift key while initiating, then it refused to open a raw file so I went in to update to accomodate my camera and got these error messages. I have been without a working photoshop program for what seems like a very long time and this is beyond acceptable. Tech support was not helpful.
    Adobe Bridge CS6 5.0.2 Update
    There was an error installing this update. Please quit and try again later. Error Code: U44M1I200
    Extension Manager 6.0.8 Update
    There was an error downloading this update. Please quit and try again later. Error Code: U43M1U49
    Adobe Bridge CS6 5.0.2 Update
    There was an error installing this update. Please quit and try again later. Error Code: U44M1I200
    Photoshop 13.1.2 for Creative Cloud
    There was an error installing this update. Please quit and try again later. Error Code: U44M1I200
    Photoshop Camera Raw 8.4(CS6)
    There was an error downloading this update. Please quit and try again later. Error Code: U43M1U49
    Adobe CSXS InfrastructureCS6
    There was an error installing this update. Please quit and try again later. Error Code: U44M1I200
    Dynamic Link Media Server CS6 1.0.1 Update
    There was an error installing this update. Please quit and try again later. Error Code: U44M1I200

    Hello Mitch4815,
    Thank you for reaching out for assistance with the New Feeds on your new Droid Bionic. I too own this device and I hope that you are as happy with yours as I am with mine. I've subscribed to the Reuter's Technology News on my Bionic so I can stay in the know on the latest and greatest rumors in the wireless world. Not only is it my job but I enjoy reading the speculation on the latest and upcoming devices. Needless to say I've had an experience that's similar to yours.
    When I received a subscription error, I had to do a factory data reset on my new Droid Bionic in order to successfully subscribe to the News Feeds. Although I do recommend that you try this, let's save this step as a last resort. Please try to remove the battery while the device is powered on & re-insert then power the device on. Afterwards, verify that you have a good 3G/4G signal, anything more than 2 bars. If you are still experiencing access issues then the factory data reset would be the next step. Here is a link on how to perform a factory data reset on a  Droid Bionic.
    http://support.verizonwireless.com/clc/devices/knowledge_base.html?id=46649
    Of course you will have to reactivate your device after the factory reset. Prior to completing the reset I recommend verifying that your contacts are backed up on either backup assistant or on your Gmail account. Also, your pictures, videos, and music will be saved on the memory card so this info is not in danger. After you have completed the steps above, please reply to this message as your experience may help others. 
    Thank you for being the best part of Verizon Wireless.

  • Adobe updates: I've gotten error messages when trying to download pdfs (very annoying). Read somewhere that mac os has problems with the adobe extensions, thus, causing error messages from adobe. I ignore the updates. Should I?

    Hi All,
    I have stopped updating adobe software b/c I read that the adobe update software inserts extensions into the mac software system, causing annoying/time consuming error messages when downloading new pdfs. I get adobe update notices 2-3x/week. What do you recommend? I use an iMac OS 10.94.
    thanks for your help.

    Preview will do all that and is part of the OS.
    Mac Basics: Preview app views and edits PDFs and images
    With Adobe, if it's working, then it should be fine. See here
    http://www.adobe.com/support/downloads/product.jsp?product=10&platform=Macintosh

  • Setting up a dailog box for an error message

    Hello everybody
      we need to display the error message that is being displayed at the bottom of the window in the portal through a pop up box.Is there a property that can be changed for an error to appear as a pop up instead of in the status bar.We are in EP6.0 SP2.
    any help is appreciated greatly.
    Thanks

    This issue can be caused by an extension that isn't working properly.
    Start Firefox in <u>[[Safe Mode]]</u> to check if one of the extensions or if hardware acceleration is causing the problem (switch to the DEFAULT theme: Firefox (Tools) > Add-ons > Appearance/Themes).
    *Don't make any changes on the Safe mode start window.
    *https://support.mozilla.com/kb/Safe+Mode
    *https://support.mozilla.com/kb/Troubleshooting+extensions+and+themes

  • IDoc acknowledgement with all error messages

    We are getting one IDoc in SAP from middleware and after it is processed we need to send acknowledgement back to sender system with all the messages in IDoc.
    I tried with ALEAUD msg type, but it seems it only send IDoc last status.
    However, requirement is to send back all error messages which came during IDoc processing to sender system, can any1 please suggest?

    Hi Hans,
    The list of all error messages is in the file ErrorMessages_en.properties.
    If you have SDK installed then this file for base ME is located in Base ME Resources/resources/properties.
    For customizations - Global Configuration/Properties
    Thanks
    Ivan

  • Idoc extension for eewb custom fields for BUS20001

    Hello.
    I have an almost exact question as , but I still need to ask what I'm supposed to do.
    We've done enhancements in EEW and I can see some append structures in CRMXIF_BUSTRANS (for example). The problem is that when I generate outbound idoc the sturcture E101CRMXIF_BUSTRANS is missing the corresponding append structures.
    Why isn't EEW adding this, or do I have to generate/re-generate something?
    I've tried to Cancel release/release the ALE interface in BDFG, but with no results.
    I think the replications (initial load and delta load) to r/3 has all EEW modifications, but when it comes to idocs, it woun't change.
    Is the only solution to create a new idoc in bdfg and create a z-structure?
    The FM ALE_CRMXIF_ORDER_SAVE_M used for populating the idoc, would work if the structure E101CRMXIF_BUSTRANS was extended with the same appendstructure (since the only thing it does is a move-corresponding...).
    So, the question is if I have to create a new z-idoc, or if it's possible to regenerate the structure used in the idoc segments?
    Regards, Mikael Löwgren

    Hi,
    When you have ignored the inconsistencies, this means the complex structure fields and the corresponding Idoc Segment fields are different in the support package.
    If this is the case, when the Idoc is regenerated in Tx BDFG, you will find the message type will be in
    error when you press F9 to do the syntax check.
    There you will see the segments which are in error as well as the 'Interface is not current and it must be regenerated' error message.
    Check those segments listed in syntax check against the respective complex structure. If there are differences like if some fields are added or the data element is changed, kindly correct the segment fields via Tx IDOC.
    If you need to add fields to the segment, you need to increase the field length of the segment in EDISDEF table, which can be done in Tx IDOC --> Repair segments tab --> Change entries in EDISDEF table.
    There you can change the field length and then change the entries in EDSAPPL table.
    Similarly if you take out all the errors in the segments listed for a particular message type and try to release the Idoc, it will be released without any errors.
    This happens, as far as my understanding goes, mainly because the complex structures might under go some changes from the development side but not the Idocs. Since both are different entities, mostly these types of things happen.
    Do let me know  if this has helped you.
    Venkat

Maybe you are looking for