Implementing SD User Exit

Dear all,
I am implementing SD User Exit first time.
Do I require Acces Key

Yes, close the tread if your query is resolved.
Regars
Vinod

Similar Messages

  • Geography based industry scenario which can be implemented using user exit

    Hi All,
    I am searching for a geography based industry scenario which can be implemented using user exit strategy.
    Please let me know me if anyone knows about any such scenario.
    Thanks & Regards,
    Pranjali.

    Hi Amith,
                   IDOC configured throgh CHANGE pointers.So no need to worry about IDOCS and all.My work was trigger idocs by user exits.Wen  ever i change venodr no.. idocs shoud be triger.
                 Now my question was Insted of going transaction( from there we can  go to debuging mode) i want to check this Exit by RBDMIDOC programe(ofter excute this programe and give Message type as CREMAS,from there i want to go debugging mode).
    Just now i checked,i put breakpoint in Include programe(INCLUDE ZXF05U01) and excute from XK01,it goes to debuging mode,so its fine.But i want triger from RBDMIDOC programe.Ofter excute RBDMIDOC programe,we can enter CREMAS.From there i want to go debuging mode.
    Pls help me,
    Thanks

  • Implement HR User Exits using BAPI's

    Hi,
    Please help me to implement User exits in HR Payroll (PBAS0001) using Bapis

    its BADI not BAPI.
    useful tcodes : Se18/19/80
    Regards
    Prabhu

  • Implementation of User Exits in SAP MDG

    Can anyone tell me whether user exits can be implemented in SAP MDG.
    Any Pointers would be helpful?

    Hi,
    Yes there are many User Exits available in SAP MDG. You can find these in SAP documentation for Master Data Governance.
    For every configuration setting, you have BADIs mentioned in the documentation provided by SAP.
    Below is the link for SAP Documentation:
    [url]http://help.sap.com/erp2005_ehp_05/helpdata/en/75/7f0a5a41904fc694f1a4a307935be5/frameset.htm
    Thank you.

  • How to implement User Exit in APO?

    Hello All,
    I am not sure how to use user exits. I was wondering if anyone can help me understand how to implement any user exit? Is there any T.Code where you do that? or ABAP coding is required? Also how different is BAdi from User exits?
    Any advice is welcome.
    Thanks,
    Sanju

    Hi Sanju,
        Check this link.
    http://www.sap-img.com/abap/difference-between-badi-and-user-exits.htm
    BADI or user exit, I don't think it is a choice between the two. Both serve the same purpose, add some custom logic to the standard logic. It depends on your requirement, the point when the user exit or BADI is called, information that is available to you in that user exit/BADI and information that you can change in that user exit/BADI. There is no difference in implementing the User Exit in APO or R/3.
    Regards,
    Siva.

  • Implementing a BADI user exit

    Hi
    I am totally new to BADI's. Now I have a specific requirement in which I need to implement BADI User Exit /SAPAPO/PPM_CALC. Method  =  CALC_BUCKET_CONS. 
    In the User Exit, remove the Splits from the PP/DS Model when the conversion to the SNP Model occurs
    Can you please guide me how to proceed briefly.. points for all helpful answers

    Hi
    Following Steps:
    1. Execute Business Add-In(BADI) transaction SE18
    2. Enter BADI name i.e. BADI_MATERIAL_CHECK and press the display
    button
    3. Select menu option Implementation->Create
    4. Give implementation a name such as Z_BADI_MATERIAL_CHECK
    5. You can now make any changes you require to the BADI within this
    implementation, for example choose the Interface tab
    6. Double click on the method you want to change, you can now enter
    any code you require.
    7. Please note to find out what import and export parameters a
    method has got return the original BADI definition
    (i.e. BADI_MATERIAL_CHECK) and double click on the method name
    for example within BADI_MATERIAL_CHECK contract is a method
    8. When changes have been made activate the implementation
    Some useful URL
    http://www.esnips.com/doc/e06e4171-29df-462f-b857-54fac19a9d8e/ppt-on-badis.ppt
    <b>good link to understand and work</b>
    http://www.esnips.com/doc/10016c34-55a7-4b13-8f5f-bf720422d265/BADIs.pdf
    http://www.esnips.com/doc/43a58f51-5d92-4213-913a-de05e9faac0d/Business-Addin.doc
    Badihttp://help.sap.com/saphelp_erp2005/helpdata/en/73/7e7941601b1d09e10000000a155106/frameset.htm
    http://support.sas.com/rnd/papers/sugi30/SAP.ppt
    http://www.sts.tu-harburg.de/teaching/sap_r3/ABAP4/abapindx.htm
    http://members.aol.com/_ht_a/skarkada/sap/
    http://www.ct-software.com/reportpool_frame.htm
    http://www.saphelp.com/SAP_Technical.htm
    http://www.kabai.com/abaps/q.htm
    http://www.guidancetech.com/people/holland/sap/abap/
    http://www.planetsap.com/download_abap_programs.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/c8/1975cc43b111d1896f0000e8322d00/content.htm
    /people/thomas.weiss/blog/2006/04/03/how-to-define-a-new-badi-within-the-enhancement-framework--part-3-of-the-series
    /people/thomas.weiss/blog/2006/04/18/how-to-implement-a-badi-and-how-to-use-a-filter--part-4-of-the-series-on-the-new-enhancement-framework
    http://esnips.com/doc/e06e4171-29df-462f-b857-54fac19a9d8e/ppt-on-badis.ppt
    http://esnips.com/doc/43a58f51-5d92-4213-913a-de05e9faac0d/Business-Addin.doc
    http://esnips.com/doc/10016c34-55a7-4b13-8f5f-bf720422d265/BADIs.pdf
    http://esnips.com/doc/1e10392e-64d8-4181-b2a5-5f04d8f87839/badi.doc
    http://esnips.com/doc/365d4c4d-9fcb-4189-85fd-866b7bf25257/customer-exits--badi.zip
    http://esnips.com/doc/3b7bbc09-c095-45a0-9e89-91f2f86ee8e9/BADI-Introduction.ppt
    http://help.sap.com//saphelp_470/helpdata/EN/eb/3e7cee940e11d295df0000e82de14a/frameset.htm
    check this links are u can easily to work .............
    look second highlighted document is good.
    if its useful reward me .
    thanks
    suresh

  • User Exit to stop the creation of PO

    Dear All,
    I have a typical problem , we have 2 servers both running on ECC 6.0.
    I tried creating a PO and I kept a break point in the exit EXIT_SAPMM06E_013 (INCLUDE ZXM06U44 ) in server1 and the control stops here and I can check all the values from the table EKKO .
    I implemented my user exit in server 2 in the same exit EXIT_SAPMM06E_013 (INCLUDE ZXM06U44 ) , when I tried to debug , I was suprised to see that the control never comes in this FM EXIT_SAPMM06E_013 , but server 1 and server 2 are both ECC6.0
    Is there any customization which I had to check from my end , so that the control can go through this user exit.
    Even if I don't implement this user exit , shouldn't the flow be going the way it was in server 1 ( I mean control going through EXIT_SAPMM06E_013 (INCLUDE ZXM06U44 ) Kindly advise..
    Best Regards,
    Srinivas Gummadi.

    Hi Srinivas,
    You need to create a project in CMOD and assign the enhancement to the project.
    The project should be activated otherwise the user exit will not be triggered.
    Regards,
    Vinod

  • User-Exit Variable

    Hi, I created a simple user-exit variable and for some reason the variable seems to get executed around 16 times and then the query gives me the below error messages.   Any ideas why my variable would have I_STEP = 2 many times before it bombs out? 
    Note: This variable is based on a Virtual Characteristic I just implemented and is probably related.  The query did not fail before trying to implement this user exit based on the Virtual Characteristic.
    Error for variable in customer enhancement ZVRSR_001
    Incorrect call of OLAP layer CL_RSR_OLAP; error in BW-BEX-ET
    *~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-
    * Load Variable with NCI Authorized Sales Rep (Sales Group)
    *~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-
      WHEN 'ZVRSR_001'.
        IF I_STEP = 2.                         "after the popup
          DATA: LT_REP    TYPE /BIC/AZ_P_O04300.
          DATA: LV_REP    TYPE /BI0/OISALES_GRP.
          SELECT SINGLE * FROM /BIC/AZ_P_O04300 INTO LT_REP
               WHERE USERNAME = SY-UNAME.
          IF SY-SUBRC = 0.
            W_L_S_RANGE-LOW = LT_REP-/BIC/ZSHTO_GRP.
          ELSE.
            W_L_S_RANGE-LOW = '???'.
          ENDIF.
          W_L_S_RANGE-SIGN = 'I'.
          W_L_S_RANGE-OPT  = 'BT'.
          APPEND W_L_S_RANGE TO E_T_RANGE.
        ENDIF.
    ENDCASE.

    OK, It looks like because it is a Virtual Characteristic that the User Exit Variable Code will be called every time the "Virtual Characteristic" code is executed as well.  The real problem seemed to be that I had used a BT in the Variable User Exit Range.  Once I changed that to "EQ' it works fine now.  Thanks

  • User exit IPRM0002 for preventive maintenance

    user exit IPRM0002 for preventive maintenance
    has anyone used this user exit? or BADI: BAdI: IPRM_MCP_SCHE_CHANGE  ?
    I seem to have some difficulty in knowing how to use these....
    I need to basically be able to influence a calling date for next PMorder to be opened but documentation is not explanatory and, even if I do know what these exit/badi are used for, i do not understand how to use the parameters provided.
    can anyone help?

    Hi,
      I dont think you would be able to test the exit if you dont implement them for the user exits simply passing the parameters wont help,actually there is a process of implementing a USER-EXIT i suppose u would already be familiar to it, I order to activate the exit you have to create a project in CMOD transaction and assign the enhancement to that and then also create the include that is avaliable inside the FM and there you would be able to put your code.
      For the BAPIs ,yes the control should go inside the BADI once you put a breakd point inside the right method but there to you need to implement the BADI and then you can put your code in the method for the effects to take place and you can test.
    The detail process of implementation are already avaliable on SCN, It seems that you dont have developer authorizations so i would suggest to take help from some one who has, Best of Luck:).
    Regards,
    Himanshu

  • Pop up screen for stock overview in ME51n through user-exit/BADI

    Hi,
    User wants that at time of  Purchase Requisition creation for any material system should give a pop up window of stock details to provide the status on inventory. 
    For stock summary the t code u201CMMBEu201D for combination of plant and material should run in background and produce output in pop up window. Basically MMBE report output is required for each item line in a pop up window.
    Can this be done through user-exit. I have implemented many user-exits but not sure about the report output in a pop up screen through a user-exit.
    The material stock ia already available under menu enviornment - Material stock(MMBE) but user wants the stock as soon as the material is enetered.
    any inputs.

    Have a look at below link which gives the details abt the user exits related to VA01/VA02.
    http://help.sap.com/saphelp_46c/helpdata/en/1c/f62c7dd435d1118b3f0060b03ca329/content.htm
    Best Regards,
    Vibha
    *Please mark all the helpful answers

  • CRM - Pricing User Exit in Java - BADI CRM_COND_COM_BADI

    Hi All
    I have to convert some user-exit from Abap to Java in order to work in CRM Pricing Scenario (I use VMC technology based on Web AS 7.00).
    In the manual attached to note 809820 (New userexit concept for pricing)
    I find this chapter but I don't understand how to work with BADI <b>CRM_COND_COM_BADI.</b>
    <b>My objective is to create Java user-exit using Custom Tables and Fileds.</b>
    <b>Passing additional information to pricing</b>
    To summarize, if the information used in a requirement is not depending on the current calculation result, then the information can be passed to the pricing engine. This is the best way to avoid e.g. DB or JCo calls from the user exits.
    Nearly all application scenarios using the pricing engine provide a way of filling additional attributes.
    1. Create a field catalogue entry for the additional attribute
    2. Program the filling of that attribute value
    The application calling the pricing engine and the way it is allowing customer code to fill or influence attributes is not part of this document. Here is only a short list of documentation to start with (also various notes exist):
    Application Description
    CRM Online Order Processing
    Implement BADI CRM_COND_COM_BADI. Note 850077
    Mobile Solutions Implement VBA user exit methods on SPCDOCHANDLER or SPCITEMHANDLER.Note 677314 and Note 934216
    Best regards
    Davide Ivanov
    [email protected]

    Hi davide,
    The BADI CRM_COND_COM_BADI is used for filling the pricing communication structure.
    If you have added any field at header level of the field catelog that will available in the changing parameter of the method HEADER_COMMUNICATION_STRUCTURE.
    If you have added any field at item level of the field catelog that will available in the changing parameter of the method ITEM_COMMUNICATION_STRUCTURE.
    Additional fields added at catelog can be filled with the values using this BADI.
    Thanks & Regards,
    Raghuram. K.R.

  • Program execution during RIMODAC2..will it  always reach to cif user exit

    Hello ,
    We are implementing cif user exit for Purchase Order at R3 side to capture additional date field. So logic to capture additional date field is put in user exit CIFPUR01. We have  RIMODAC2  background job for Purchase order running on daily basis.
    if there is no change in standard Purchase Order objects. When RIMODAC2 is executed  for purchase order Integration models ..will  program execution still always reach to R3  user exit part of the program irrespective of if  any change in standard purchase order object has happened or not.
    Will appreciate your answer.
    Thank you
    Best Regards
    Nilesh Patil

    Nilesh,
    I am no longer sure I understand the question.
    RIMODAC2 activates the model.  Once a model is activated, if someone changes certain specific fields in an R/3 object, then these changes are sent to SCM, either immediately or via change pointers.  All this happens irrespective of IM userexits.
    If this same field in this same object is changed in R/3, and a userexit also has been implemented, the  userexit will execute according to its design,  performing whatever task it has been programmed to do.
    If you create and implement a userexit, it begins working at that moment in time that it is installed.  Data that flowed across 'yesterday' to SCM is not affected.  Data that flows across 'tomorrow' will be affected.  Data in R/3 will usually only flow across to SCM if there is some kind of triggering event, usually a database 'change' transaction (e.g., ME22N for POs) The mere act of installing a userexit will not generally affect existing data on either side.  The userexit only affects data that flows across the IM. Unchanged records in the R/3 database will generally not be sent to SCM by the IM, and will not be subject to userexit processing.
    It is not generally the responsibility of a functional consultant to explain the workings of a userexit to a technical consultant.  It is enough that the functional identifies the userexit, and specifies the business requirement in as much detail as possible.  The developer is then responsible for carrying out the coding.  Technicals are generally expected to be competent enough to determine from the userexit docs, and from the surrounding code, how a userexit works.  They can also raise a message to SAP.  In the end, it is all just ABAP, although userexit implementations can be quite challenging. SAP seldom provides enough details in their documentation.   Once the Technical has finalized the code, Functional and Technical together then perform unit testing, before passing the mods to users for integration testing.
    If your client's coders are unable to manage the task, perhaps they should engage your company to provide technical expertise, as well as functional expertise.
    Best Regards,
    DB49

  • BAdi & user-exits while upgrade from 4.6c to ECC6

    Hello all,
    Can anybody put light on how User-exits and BAdi will be effected while upgrade from lower version to ECC6.
    Many Thnanks.....
    Apps.

    Hi,
    The main concept of enhancements is to keep the code unaffected during version upgrades
    Hence all the BADI implementations and User Exit/Customer exits implementations will be in place and no effect due to upgrade...I hope in case of badi, some new BADI(as part of enhancement framework-GET BADI/CALL BADI) will be added up and the old BADI(Those in 4.6c or below) will not get affected.
    Regards
    Shiva

  • Infotype check and user exit

    hi All,
    With the help of answer from my previous post I understand that I need to implement a user exit to do a particular check on my field. Actually when a user inputs a field then i need to compare it to field from some other table.
    My doubt is what user exit i need to use..
    ZXPADU01 or ZXPADU02 or ZXPADU03.
    My understanding is that ZX*02 is for me since it is implemented in PAI module of screen 2000 for MP999900.
    Also can someone explain what different situations we need to use this exits?
    Also please mention if BADI exists with the same functionality.
    thanks and regards,
    Reena

    if it is a Z infotype then as per my previous post just go to se80 and ur concerend module pool program.
    and write a module in PAI on tht particular field as in my post..
    if u want to compare it with another table value then u can simply  fetch data frm tht table in this module and compare it with ur field.
    U need not to go for USer Exit for the Z infotype.
    amit

  • User-exit for program RFPNFC00

    I need to create an ACH format file. For this i'm using program RFPNFC00 to create file.
    I need to modify few things in the file for which i need any user-exit available to do the required modifications. Please lemme know if anyone have used this program to create file and implemented any user-exit to modify the ACH file format.
    Regards
    VEnk@

    I am not wble to find any exit but i have the following two suggestions.
    1. I can see lot of subroutines where you can create implicit enhancemnts and modify the data accordingly to solve your purpose.
    2. This approach i usually dont prefer but it depends on person to person. You can create a Z copy of report and do modifications.
    I will advise you find a suitable point and do implicit enhancement.
    Nabheet

Maybe you are looking for