Important function modules

Hi,
Can you tell me list of important Function modules used in ABAP or send me a doc please?
My email id: [email protected]
Thanks in advance.

Nuren,
Its all depends on what you need, you can get the list from se37 itself. Whenever you need to search, you can first use of searching with descrition by giving download .....
Similarly you can search in the same way for function groups and then the list of FM's under this FG.
See these links
<a href="http://www.sapdevelopment.co.uk/fmodules/fmssap.htm">http://www.sapdevelopment.co.uk/fmodules/fmssap.htm</a>
<a href="http://planetsap.com/Useful_function_modules.htm">http://planetsap.com/Useful_function_modules.htm</a>
<a href="http://www.sapgenie.com/abap/functions.htm">http://www.sapgenie.com/abap/functions.htm</a>
Regds
Manohar

Similar Messages

  • GTS tables relations and important function modules

    Hi Friends,
    I am totally new for the developments in GTS.  Wanted some help on the  tables for master data, transactional data in GTS. 
    Also what are the important function modules used in GTS.
    Anybody can give me some inputs on the above..?
    regards
    Nalin

    Well, passing a table thru the interface with no type is easy, just don't assign a structure when defining the interface.  It will then take its structure by what is being passed to it. 
    So if you would pass an internal table to it with the structure like so.
    Data: begin of itab occurs 0,
          line(1000) type c,
          end  of itab.
    Then that is the structure inside the function module. 
    Did this answer your question?   Please explain further if not.
    Regards,
    Rich Heilman

  • Function module used for formatting alv

    hi gurus,
    which function module is uesd to format alv?

    Hi
    see the following
    ABAP List Viewer
    The common features of report are column alignment, sorting, filtering, subtotals, totals etc. To implement these, a lot of coding and logic is to be put. To avoid that we can use a concept called ABAP List Viewer (ALV).
    This helps us to implement all the features mentioned very effectively.
    Using ALV, We can have three types of reports:
    1. Simple Report
    2. Block Report
    3. Hierarchical Sequential Report
    There are some function modules which will enable to produce the above reports without much effort.
    All the definitions of internal tables, structures and constants are declared in a type-pool called SLIS.
    1. SIMPLE REPORT.
    The important function modules are
    a. Reuse_alv_list_display
    b. Reuse_alv_fieldcatalog_merge
    c. Reuse_alv_events_get
    d. Reuse_alv_commentary_write
    e. Reuse_alv_grid_display
    A. REUSE_ALV_LIST_DISPLAY : This is the function module which prints the data.
    The important parameters are :
    I. Export :
    i. I_callback_program : report id
    ii. I_callback_pf_status_set : routine where a user can set his own pf status or change the functionality of the existing pf status
    iii. I_callback_user_command : routine where the function codes are handled
    iv. I_structure name : name of the dictionary table
    v. Is_layout : structure to set the layout of the report
    vi. It_fieldcat : internal table with the list of all fields and their attributes which are to be printed (this table can be populated automatically by the function module REUSE_ALV_FIELDCATALOG_MERGE
    vii. It_events : internal table with a list of all possible events of ALV and their corresponding form names.
    II. Tables :
    i. t_outtab : internal table with the data to be output
    B. REUSE_ALV_FIELDCATALOG_MERGE : This function module is used to populate a fieldcatalog which is essential to display the data in ALV. If the output data is from a single dictionary table and all the columns are selected, then we need not exclusively create the field catalog. Its enough to mention the table name as a parameter(I_structure name) in the REUSE_ALV_LIST_DISPLAY. But in other cases we need to create it.
    The Important Parameters are :
    I. Export :
    i. I_program_name : report id
    ii. I_internal_tabname : the internal output table
    iii. I_inclname : include or the report name where all the dynamic forms are handled.
    II Changing
    ct_fieldcat : an internal table with the type SLIS_T_FIELDCAT_ALV which is
    declared in the type pool SLIS.
    C. REUSE_ALV_EVENTS_GET : Returns table of possible events for a list type
    Parameters :
    I. Import :
    Et_Events : The event table is returned with all possible CALLBACK events
    for the specified list type (column 'NAME'). For events to be processed by Callback, their 'FORM' field must be filled. If the field is initialized, the event is ignored. The entry can be read from the event table, the field 'FORM' filled and the entry modified using constants from the type pool SALV.
    II. Export :
    I_List_type :
    0 = simple list REUSE_ALV_LIST_DISPLAY
    1 = hierarchcal-sequential list REUSE_ALV_HIERSEQ_LIST_DISPLAY
    2 = simple block list REUSE_ALV_BLOCK_LIST_APPEND
    3 = hierarchical-sequential block list
    REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_COMMENTARY_WRITE : This is used in the Top-of-page event to print the headings and other comments for the list.
    Parameters :
    I. it_list_commentary : internal table with the headings of the type slis_t_listheader.
    This internal table has three fields :
    Typ : ‘H’ – header, ‘S’ – selection , ‘A’ - action
    Key : only when typ is ‘S’.
    Info : the text to be printed
    E. REUSE_ALV_GRID_DISPLAY : A new function in 4.6 version, to display the results in grid rather than as a preview.
    Parameters : same as reuse_alv_list_display
    This is an example for simple list.
    2. BLOCK REPORT
    This is used to have multiple lists continuously.
    The important functions used in this report are:
    A. REUSE_ALV_BLOCK_LIST_INIT
    B. REUSE_ALV_BLOCK_LIST_APPEND
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    A. REUSE_ALV_BLOCK_LIST_INIT
    Parameters:
    I. I_CALLBACK_PROGRAM
    II. I_CALLBACK_PF_STATUS_SET
    III. I_CALLBACK_USER_COMMAND
    This function module is used to set the default gui status etc.
    B. REUSE_ALV_BLOCK_LIST_APPEND
    Parameters :
    Export :
    I. is_layout : layout settings for block
    II. it_fieldcat : field catalog
    III. i_tabname : internal table name with output data
    IV. it_events : internal table with all possible events
    Tables :
    i. t_outtab : internal table with output data.
    This function module adds the data to the block.
    Repeat this function for all the different blocks to be displayed one after the other.
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    This function module is used for hierarchical sequential blocks.
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    Parameters : All the parameters are optional.
    This function module display the list with data appended by the above function.
    Here the functions REUSE_ALV_FIELDCATALOG_MERGE, REUSE_ALV_EVENTS_GET, REUSE_ALV_COMMENTARY_WRITE can be used.
    3. Hierarchical reports :
    Hierarchical sequential list output.
    The function module is
    A. REUSE_ALV_HIERSEQ_LIST_DISPLAY
    Parameters:
    I. Export:
    i. I_CALLBACK_PROGRAM
    ii. I_CALLBACK_PF_STATUS_SET
    iii. I_CALLBACK_USER_COMMAND
    iv. IS_LAYOUT
    v. IT_FIELDCAT
    vi. IT_EVENTS
    vii. i_tabname_header : Name of the internal table in the program containing the
    output data of the highest hierarchy level.
    viii. i_tabname_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    ix. is_keyinfo : This structure contains the header and item table field
    names which link the two tables (shared key).
    II. Tables
    i. t_outtab_header : Header table with data to be output
    ii. t_outtab_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    slis_t_fieldcat_alv : This internal table contains the field attributes. This internal table can be populated automatically by using ‘REUSE_ALV_FIELDCATALOG_MERGE’.
    Important Attributes :
    A. col_pos : position of the column
    B. fieldname : internal fieldname
    C. tabname : internal table name
    D. ref_fieldname : fieldname (dictionary)
    E. ref_tabname : table (dictionary)
    F. key(1) : column with key-color
    G. icon(1) : icon
    H. symbol(1) : symbol
    I. checkbox(1) : checkbox
    J. just(1) : (R)ight (L)eft (C)ent.
    K. do_sum(1) : sum up
    L. no_out(1) : (O)blig.(X)no out
    M. outputlen : output length
    N. seltext_l : long key word
    O. seltext_m : middle key word
    P. seltext_s : short key word
    Q. reptext_ddic : heading (ddic)
    R. ddictxt(1) : (S)hort (M)iddle (L)ong
    S. datatype : datatype
    T. hotspot(1) : hotspot
    Simple ALV report
    http://www.sapgenie.com/abap/controls/alvgrid.htm
    http://wiki.ittoolbox.com/index.php/Code:Ultimate_ALV_table_toolbox
    ALV
    1. Please give me general info on ALV.
    http://www.sapfans.com/forums/viewtopic.php?t=58286
    http://www.sapfans.com/forums/viewtopic.php?t=76490
    http://www.sapfans.com/forums/viewtopic.php?t=20591
    http://www.sapfans.com/forums/viewtopic.php?t=66305 - this one discusses which way should you use - ABAP Objects calls or simple function modules.
    2. How do I program double click in ALV?
    http://www.sapfans.com/forums/viewtopic.php?t=11601
    http://www.sapfans.com/forums/viewtopic.php?t=23010
    Check the program in the following link:
    http://sap-img.com/abap/display-secondary-list-using-alv-grid.htm
    3. How do I add subtotals (I have problem to add them)...
    http://www.sapfans.com/forums/viewtopic.php?t=20386
    http://www.sapfans.com/forums/viewtopic.php?t=85191
    http://www.sapfans.com/forums/viewtopic.php?t=88401
    http://www.sapfans.com/forums/viewtopic.php?t=17335
    http://www.sapdevelopment.co.uk/reporting/alv/alvgrid_basic.htm
    4. How to add list heading like top-of-page in ABAP lists?
    http://www.sapfans.com/forums/viewtopic.php?t=58775
    http://www.sapfans.com/forums/viewtopic.php?t=60550
    http://www.sapfans.com/forums/viewtopic.php?t=16629
    5. How to print page number / total number of pages X/XX in ALV?
    http://www.sapfans.com/forums/viewtopic.php?t=29597 (no direct solution)
    6. ALV printing problems. The favourite is: The first page shows the number of records selected but I don't need this.
    http://www.sapfans.com/forums/viewtopic.php?t=64320
    http://www.sapfans.com/forums/viewtopic.php?t=44477
    7. How can I set the cell color in ALV?
    http://www.sapfans.com/forums/viewtopic.php?t=52107
    8. How do I print a logo/graphics in ALV?
    http://www.sapfans.com/forums/viewtopic.php?t=81149
    http://www.sapfans.com/forums/viewtopic.php?t=35498
    http://www.sapfans.com/forums/viewtopic.php?t=5013
    9. How do I create and use input-enabled fields in ALV?
    http://www.sapfans.com/forums/viewtopic.php?t=84933
    http://www.sapfans.com/forums/viewtopic.php?t=69878
    10. How can I use ALV for reports that are going to be run in background?
    http://www.sapfans.com/forums/viewtopic.php?t=83243
    http://www.sapfans.com/forums/viewtopic.php?t=19224
    11. How can I display an icon in ALV? (Common requirement is traffic light icon).
    http://www.sapfans.com/forums/viewtopic.php?t=79424
    http://www.sapfans.com/forums/viewtopic.php?t=24512
    12. How can I display a checkbox in ALV?
    http://www.sapfans.com/forums/viewtopic.php?t=88376
    http://www.sapfans.com/forums/viewtopic.php?t=40968
    http://www.sapfans.com/forums/viewtopic.php?t=6919
    13. Top-of-page in ALV
    selection-screen and top-of-page in ALV
    14.  ALV Group Heading
    http://www.sap-img.com/fu037.htm
    How to add list heading like top-of-page in ABAP lists?
    http://www.sapfans.com/forums/viewtopic.php?t=58775
    http://www.sapfans.com/forums/viewtopic.php?t=60550
    http://www.sapfans.com/forums/viewtopic.php?t=16629
    15. ALV output to PDF conversion
    It has an example code for PDF Conversion.
    http://www.erpgenie.com/abap/code/abap51.htm
    converting the output of alv in pdf
    Go thru these programs they may help u to try on some hands on
    ALV Demo program
    BCALV_DEMO_HTML
    BCALV_FULLSCREEN_DEMO ALV Demo: Fullscreen Mode
    BCALV_FULLSCREEN_DEMO_CLASSIC ALV demo: Fullscreen mode
    BCALV_GRID_DEMO Simple ALV Control Call Demo Program
    BCALV_TREE_DEMO Demo for ALV tree control
    BCALV_TREE_SIMPLE_DEMO
    BC_ALV_DEMO_HTML_D0100
    Regards
    Anji

  • What are function modules used in alv,and its explanation

    what are function modules used in alv,and its explanation

    hi..
    The important function modules are
    Reuse_alv_fieldcatalog_merge
    Reuse_alv_list_display
    Reuse_alv_events_get
    Reuse_alv_grid_display
    Reuse_alv_commentary_write.
    <b>REUSE_ALV_FIELDCATALOG_MERGE</b>
          This function module is used to populate a field catalog which is essential to display the data in ALV.
          If the output data is from a single dictionary table and all the columns are selected, then we need not exclusively create the field catalog. Its enough to mention the table name as a parameter (I_structure_name) in the REUSE_ALV_LIST_DISPLAY. But in other cases we need to create it.
    Note : Fieldcatalog can be filled manually also by filling up all the required details into the internal table     
    The important parameters are:
       1. Export:
            a. I_program_name     : report id
            b. I_internal_tabname     : the internal output table     
            c. I_inclname     : include or the report name where all  
                                                 the dynamic forms are handled.
        2. Changing
           ct_fieldcat     :    an internal table with the type 
                                      SLIS_T_FIELDCAT_ALV which is declared in the
                                      type pool SLIS.
    <b>REUSE_ALV_LIST_DISPLAY</b>
    This is the function module which prints the data.
    The important parameters are:
    1. Export:
          I_callback_program            : report id
          I_bypassing_buffer             : ‘X’
          I_buffer_active                    : ‘ ‘
          I_callback_pf_status_set     : routine where a user can set
                                                             his own pf status or change the
                                                             functionality of the existing pf status.
          I_callback_user_command : routine where the function codes are
                                                               handled.
          I_structure name     : name of the dictionary table
          Is_Layout          : structure to set the layout of the report
          It_fieldcat          : internal table with the list of all fields and their
                                                 attributes which are to be printed (this table
                                                 can be populated automatically by the function
                                                 REUSE_ALV_FIELDCATALOG_MERGE
          It_events          : internal table with a list of all possible events
                                                 of ALV and their corresponding form names.
    2.  Tables:
         a. t_outtab     : internal table with the data to be output
    <b>REUSE_ALV_EVENTS_GET: </b>
          Returns table of possible events for a a list type
    1. Import:
          Et_Events      :
          The event table is returned with all possible CALLBACK events for the specified list type (column ‘NAME’). For events to be processed by the Callback, their ‘FORM’ field must be filled. If the field is initialized, the event is ignored. The entry can be read from the event table, the field ‘FORM’ filled and the entry modified using constants from the type pool SLIS.
    2. Export:
        I_list_type:
              0 = simple list REUSE_ALV_LIST_DISPLAY
              1 = hierarchical-sequential list                                           
                    REUSE_ALV_HIERSEQ_LIST_DISPLAY
              2 = simple block list                                                        REUSE_ALV_BLOCK_LIST_APPEND
              3 = hierarchical-sequential block list
                    REUSE_ALV_BLOCK_LIST_HS_APPEND
    <b>REUSE_ALV_GRID_DISPLAY</b>
      A new function from 4.6 version, to display the results in grid rather than a
      preview.
      Parameters : same as reuse_alv_list_display
    <b>REUSE_ALV_COMMENTARY_WRITE</b>
    This is used in the Top-of-page event  to print the headings and other
    comments for the list.
    It_list_commentary : Internal table with the headings of the type
                                             slis_t_listheader.
        This internal table has three fields:
        Typ : ‘H’ - header, ‘S’ - selection, ‘A’ - action
        Key : only when typ is ‘S’.
        Info : the text to be printed
    <b>plz reward pts if helpful.</b>
    regards
    vijay.

  • List of function modules

    Hi All,
           Can anyone tell me how to get a list of all important function modules and thier description.and also what are important parameters to be passed for respective Function Module.
    Thanks In Advance.

    Hi
    Check this
    lso check these links.
    http://www.geocities.com/victorav15/sapr3/abapfun.html
    Check this link:
    http://help.sap.com/saphelp_erp2004/helpdata/en/9f/db988735c111d1829f0000e829fbfe/content.htm
    http://help.sap.com/saphelp_nw2004s/helpdata/en/ef/d94b78ebf811d295b100a0c94260a5/frameset.htm
    http://help.sap.com/saphelp_nw2004s/helpdata/en/43/41341147041806e10000000a1553f6/frameset.htm
    Check this link:
    http://help.sap.com/saphelp_erp2004/helpdata/en/9f/db988735c111d1829f0000e829fbfe/content.htm
    http://help.sap.com/saphelp_nw2004s/helpdata/en/ef/d94b78ebf811d295b100a0c94260a5/frameset.htm
    http://help.sap.com/saphelp_nw2004s/helpdata/en/43/41341147041806e10000000a1553f6/frameset.htm
    See the following links:
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/9f/db970e35c111d1829f0000e829fbfe/frameset.htm
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/9f/db970e35c111d1829f0000e829fbfe/frameset.htm
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/9f/db970e35c111d1829f0000e829fbfe/frameset.htm
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/9f/db970e35c111d1829f0000e829fbfe/frameset.htm
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/9f/db970e35c111d1829f0000e829fbfe/frameset.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/26/64f623fa8911d386e70000e82011b8/content.htm
    Reward points for useful Answers
    Regards
    Anji

  • Regarding ALV Function modules

    Hi,
           Can you please explain what is the difference betweeen slis_fieldcat_alv and slis_t_fieldcat_alv?
    thnx
    venkat

    Hi
    ABAP List Viewer
    The common features of report are column alignment, sorting, filtering, subtotals, totals etc. To implement these, a lot of coding and logic is to be put. To avoid that we can use a concept called ABAP List Viewer (ALV).
    This helps us to implement all the features mentioned very effectively.
    Using ALV, We can have three types of reports:
    1. Simple Report
    2. Block Report
    3. Hierarchical Sequential Report
    There are some function modules which will enable to produce the above reports without much effort.
    All the definitions of internal tables, structures and constants are declared in a type-pool called SLIS.
    1. SIMPLE REPORT.
    The important function modules are
    a. Reuse_alv_list_display
    b. Reuse_alv_fieldcatalog_merge
    c. Reuse_alv_events_get
    d. Reuse_alv_commentary_write
    e. Reuse_alv_grid_display
    A. REUSE_ALV_LIST_DISPLAY : This is the function module which prints the data.
    The important parameters are :
    I. Export :
    i. I_callback_program : report id
    ii. I_callback_pf_status_set : routine where a user can set his own pf status or change the functionality of the existing pf status
    iii. I_callback_user_command : routine where the function codes are handled
    iv. I_structure name : name of the dictionary table
    v. Is_layout : structure to set the layout of the report
    vi. It_fieldcat : internal table with the list of all fields and their attributes which are to be printed (this table can be populated automatically by the function module REUSE_ALV_FIELDCATALOG_MERGE
    vii. It_events : internal table with a list of all possible events of ALV and their corresponding form names.
    II. Tables :
    i. t_outtab : internal table with the data to be output
    B. REUSE_ALV_FIELDCATALOG_MERGE : This function module is used to populate a fieldcatalog which is essential to display the data in ALV. If the output data is from a single dictionary table and all the columns are selected, then we need not exclusively create the field catalog. Its enough to mention the table name as a parameter(I_structure name) in the REUSE_ALV_LIST_DISPLAY. But in other cases we need to create it.
    The Important Parameters are :
    I. Export :
    i. I_program_name : report id
    ii. I_internal_tabname : the internal output table
    iii. I_inclname : include or the report name where all the dynamic forms are handled.
    II Changing
    ct_fieldcat : an internal table with the type SLIS_T_FIELDCAT_ALV which is
    declared in the type pool SLIS.
    C. REUSE_ALV_EVENTS_GET : Returns table of possible events for a list type
    Parameters :
    I. Import :
    Et_Events : The event table is returned with all possible CALLBACK events
    for the specified list type (column 'NAME'). For events to be processed by Callback, their 'FORM' field must be filled. If the field is initialized, the event is ignored. The entry can be read from the event table, the field 'FORM' filled and the entry modified using constants from the type pool SALV.
    II. Export :
    I_List_type :
    0 = simple list REUSE_ALV_LIST_DISPLAY
    1 = hierarchcal-sequential list REUSE_ALV_HIERSEQ_LIST_DISPLAY
    2 = simple block list REUSE_ALV_BLOCK_LIST_APPEND
    3 = hierarchical-sequential block list
    REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_COMMENTARY_WRITE : This is used in the Top-of-page event to print the headings and other comments for the list.
    Parameters :
    I. it_list_commentary : internal table with the headings of the type slis_t_listheader.
    This internal table has three fields :
    Typ : ‘H’ – header, ‘S’ – selection , ‘A’ - action
    Key : only when typ is ‘S’.
    Info : the text to be printed
    E. REUSE_ALV_GRID_DISPLAY : A new function in 4.6 version, to display the results in grid rather than as a preview.
    Parameters : same as reuse_alv_list_display
    This is an example for simple list.
    2. BLOCK REPORT
    This is used to have multiple lists continuously.
    The important functions used in this report are:
    A. REUSE_ALV_BLOCK_LIST_INIT
    B. REUSE_ALV_BLOCK_LIST_APPEND
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    A. REUSE_ALV_BLOCK_LIST_INIT
    Parameters:
    I. I_CALLBACK_PROGRAM
    II. I_CALLBACK_PF_STATUS_SET
    III. I_CALLBACK_USER_COMMAND
    This function module is used to set the default gui status etc.
    B. REUSE_ALV_BLOCK_LIST_APPEND
    Parameters :
    Export :
    I. is_layout : layout settings for block
    II. it_fieldcat : field catalog
    III. i_tabname : internal table name with output data
    IV. it_events : internal table with all possible events
    Tables :
    i. t_outtab : internal table with output data.
    This function module adds the data to the block.
    Repeat this function for all the different blocks to be displayed one after the other.
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    This function module is used for hierarchical sequential blocks.
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    Parameters : All the parameters are optional.
    This function module display the list with data appended by the above function.
    Here the functions REUSE_ALV_FIELDCATALOG_MERGE, REUSE_ALV_EVENTS_GET, REUSE_ALV_COMMENTARY_WRITE can be used.
    3. Hierarchical reports :
    Hierarchical sequential list output.
    The function module is
    A. REUSE_ALV_HIERSEQ_LIST_DISPLAY
    Parameters:
    I. Export:
    i. I_CALLBACK_PROGRAM
    ii. I_CALLBACK_PF_STATUS_SET
    iii. I_CALLBACK_USER_COMMAND
    iv. IS_LAYOUT
    v. IT_FIELDCAT
    vi. IT_EVENTS
    vii. i_tabname_header : Name of the internal table in the program containing the
    output data of the highest hierarchy level.
    viii. i_tabname_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    ix. is_keyinfo : This structure contains the header and item table field
    names which link the two tables (shared key).
    II. Tables
    i. t_outtab_header : Header table with data to be output
    ii. t_outtab_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    slis_t_fieldcat_alv : This internal table contains the field attributes. This internal table can be populated automatically by using ‘REUSE_ALV_FIELDCATALOG_MERGE’.
    Important Attributes :
    A. col_pos : position of the column
    B. fieldname : internal fieldname
    C. tabname : internal table name
    D. ref_fieldname : fieldname (dictionary)
    E. ref_tabname : table (dictionary)
    F. key(1) : column with key-color
    G. icon(1) : icon
    H. symbol(1) : symbol
    I. checkbox(1) : checkbox
    J. just(1) : (R)ight (L)eft (C)ent.
    K. do_sum(1) : sum up
    L. no_out(1) : (O)blig.(X)no out
    M. outputlen : output length
    N. seltext_l : long key word
    O. seltext_m : middle key word
    P. seltext_s : short key word
    Q. reptext_ddic : heading (ddic)
    R. ddictxt(1) : (S)hort (M)iddle (L)ong
    S. datatype : datatype
    T. hotspot(1) : hotspot
    Regards
    Anji

  • Hi guru's what are the function modules are used in ALV

    hi guru's what are the function modules are used in ALV

    Hi vasu,
    There are some function modules which will enable to produce the  reports without much effort.
    All the definitions of internal tables, structures and constants are declared in a type-pool called SLIS.
    1. SIMPLE REPORT.
    The important function modules are
    a. Reuse_alv_list_display
    b. Reuse_alv_fieldcatalog_merge
    c. Reuse_alv_events_get
    d. Reuse_alv_commentary_write
    e. Reuse_alv_grid_display
    A. REUSE_ALV_LIST_DISPLAY : This is the function module which prints the data.
    The important parameters are :
    I. Export :
    i. I_callback_program : report id
    ii. I_callback_pf_status_set : routine where a user can set his own pf status or change the functionality of the existing pf status
    iii. I_callback_user_command : routine where the function codes are handled
    iv. I_structure name : name of the dictionary table
    v. Is_layout : structure to set the layout of the report
    vi. It_fieldcat : internal table with the list of all fields and their attributes which are to be printed (this table can be populated automatically by the function module REUSE_ALV_FIELDCATALOG_MERGE
    vii. It_events : internal table with a list of all possible events of ALV and their corresponding form names.
    II. Tables :
    i. t_outtab : internal table with the data to be output
    B. REUSE_ALV_FIELDCATALOG_MERGE : This function module is used to populate a fieldcatalog which is essential to display the data in ALV. If the output data is from a single dictionary table and all the columns are selected, then we need not exclusively create the field catalog. Its enough to mention the table name as a parameter(I_structure name) in the REUSE_ALV_LIST_DISPLAY. But in other cases we need to create it.
    The Important Parameters are :
    I. Export :
    i. I_program_name : report id
    ii. I_internal_tabname : the internal output table
    iii. I_inclname : include or the report name where all the dynamic forms are handled.
    II Changing
    ct_fieldcat : an internal table with the type SLIS_T_FIELDCAT_ALV which is
    declared in the type pool SLIS.
    C. REUSE_ALV_EVENTS_GET : Returns table of possible events for a list type
    Parameters :
    I. Import :
    Et_Events : The event table is returned with all possible CALLBACK events
    for the specified list type (column 'NAME'). For events to be processed by Callback, their 'FORM' field must be filled. If the field is initialized, the event is ignored. The entry can be read from the event table, the field 'FORM' filled and the entry modified using constants from the type pool SALV.
    II. Export :
    I_List_type :
    0 = simple list REUSE_ALV_LIST_DISPLAY
    1 = hierarchcal-sequential list REUSE_ALV_HIERSEQ_LIST_DISPLAY
    2 = simple block list REUSE_ALV_BLOCK_LIST_APPEND
    3 = hierarchical-sequential block list
    REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_COMMENTARY_WRITE : This is used in the Top-of-page event to print the headings and other comments for the list.
    Parameters :
    I. it_list_commentary : internal table with the headings of the type slis_t_listheader.
    This internal table has three fields :
    Typ : ‘H’ – header, ‘S’ – selection , ‘A’ - action
    Key : only when typ is ‘S’.
    Info : the text to be printed
    E. REUSE_ALV_GRID_DISPLAY : A new function in 4.6 version, to display the results in grid rather than as a preview.
    Parameters : same as reuse_alv_list_display
    This is an example for simple list.
    2. BLOCK REPORT
    This is used to have multiple lists continuously.
    The important functions used in this report are:
    A. REUSE_ALV_BLOCK_LIST_INIT
    B. REUSE_ALV_BLOCK_LIST_APPEND
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    A. REUSE_ALV_BLOCK_LIST_INIT
    Parameters:
    I. I_CALLBACK_PROGRAM
    II. I_CALLBACK_PF_STATUS_SET
    III. I_CALLBACK_USER_COMMAND
    This function module is used to set the default gui status etc.
    B. REUSE_ALV_BLOCK_LIST_APPEND
    Parameters :
    Export :
    I. is_layout : layout settings for block
    II. it_fieldcat : field catalog
    III. i_tabname : internal table name with output data
    IV. it_events : internal table with all possible events
    Tables :
    i. t_outtab : internal table with output data.
    This function module adds the data to the block.
    Repeat this function for all the different blocks to be displayed one after the other.
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    This function module is used for hierarchical sequential blocks.
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    Parameters : All the parameters are optional.
    This function module display the list with data appended by the above function.
    Here the functions REUSE_ALV_FIELDCATALOG_MERGE, REUSE_ALV_EVENTS_GET, REUSE_ALV_COMMENTARY_WRITE can be used.
    3. Hierarchical reports :
    Hierarchical sequential list output.
    The function module is
    A. REUSE_ALV_HIERSEQ_LIST_DISPLAY
    Parameters:
    I. Export:
    i. I_CALLBACK_PROGRAM
    ii. I_CALLBACK_PF_STATUS_SET
    iii. I_CALLBACK_USER_COMMAND
    iv. IS_LAYOUT
    v. IT_FIELDCAT
    vi. IT_EVENTS
    vii. i_tabname_header : Name of the internal table in the program containing the
    output data of the highest hierarchy level.
    viii. i_tabname_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    ix. is_keyinfo : This structure contains the header and item table field
    names which link the two tables (shared key).
    II. Tables
    i. t_outtab_header : Header table with data to be output
    ii. t_outtab_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    slis_t_fieldcat_alv : This internal table contains the field attributes. This internal table can be populated automatically by using ‘REUSE_ALV_FIELDCATALOG_MERGE’.
    Important Attributes :
    A. col_pos : position of the column
    B. fieldname : internal fieldname
    C. tabname : internal table name
    D. ref_fieldname : fieldname (dictionary)
    E. ref_tabname : table (dictionary)
    F. key(1) : column with key-color
    G. icon(1) : icon
    H. symbol(1) : symbol
    I. checkbox(1) : checkbox
    J. just(1) : (R)ight (L)eft (C)ent.
    K. do_sum(1) : sum up
    L. no_out(1) : (O)blig.(X)no out
    M. outputlen : output length
    N. seltext_l : long key word
    O. seltext_m : middle key word
    P. seltext_s : short key word
    Q. reptext_ddic : heading (ddic)
    R. ddictxt(1) : (S)hort (M)iddle (L)ong
    S. datatype : datatype
    T. hotspot(1) : hotspot
    some theory regarding alv:
    This table tells ALV which events are processed by the caller by CALLBACK.
    The table of possible events per list type can be initialized using the module REUSE_ALV_EVENTS_GET.
    You can display the names of the constants in the type pools SLIS which represent the individual events using the individual test function in the function module
    REUSE_ALV_EVENT_NAMES_GET. Only events with a form routine name are processed.
    The table structure contains the fields:
    • IT_EVENTS-NAME
    Name of the Callback event.
    Possible Callback events:
    • Action
    USER_COMMAND USING R_UCOMM LIKE SY-UCOMM RS_SELFIELD TYPE SLIS_SELFIELD
    Process actions on the list
    As this is a frequently-used Callback event, the form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_USER_COMMAND.
    PF_STATUS_SET USING RT_EXTAB TYPE SLIS_T_EXTAB
    If a user list status is to be set, it must be done in the form routine assigned to this event. The ALV function codes, which must not be active, are in the Parameter RT_EXTAB. This table must be passed with the SET PF-STATUS command (with inactive user function codes as well, if necessary).
    The STANDARD status of the function group SALV should be used as a template for a user-specific status.
    As this is a frequently-used Callback event, its form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_PF_STATUS_SET.
    ITEM_DATA_EXPAND USING RS_SELFIELD TYPE SLIS_SELFIELD RFLG_ALL TYPE C
    Only relevant for hierarchical-sequential lists using the layout parameter IS_LAYOUT-EXPAND_FIELDNAME of the structure IS_LAYOUT.
    Exit for passing item entries (ITEM table) for a header record which was expanded interactively by the user.
    RS_SELFIELD-TABINDEX contains the header table index for which the item entries are to be put in the global item output table (T_OUTTAB_SLAVE). The Callback is only called if ALV has no items for a header which is to be expanded.
    RFLG_ALL is passed with 'X' if the user shows all items. The application must ensure that entries are not repeated in the item table. RS_SELFIELD is initial in this case.
    CALLER_EXIT USING RS_DATA Is called at the beginning of the function module to make special settings. It is not usually used.
    • List processing events
    IMPORTANT: The application Callback routine must not manipulate the internal output table and/or its header record. This restriction applies to all Callbacks which are called in the list output and run under the 'List processing events'.
    TOP_OF_LIST no USING parameter. Information output at the start of the list
    END_OF_LIST no USING parameter. Information output at the end of the list
    TOP_OF_PAGE no USING parameter
    Equivalent to the list processing TOP-OF-PAGE event
    END_OF_PAGE no USING parameter. Not available for hierarchical-sequential lists.
    Information output at the end of a page. This is only called for printing.
    TOP_OF_COVERPAGE no USING parameter
    The selection information and list status are output together (if they exist) on a separate page by default. See also the documentation of the parameters:
    IS_PRINT-NO_COVERPAGE
    IS_PRINT-NO_PRINT_SELINFOS
    IS_PRINT-NO_PRINT_LISTINFOS
    IS_LAYOUT-GET_SELINFOS
    The user can format the header area of the 'cover page' himself or herself by specifying a Callback routine for this event.
    END_OF_COVERPAGE no USING parameter
    Analogously to TOP_OF_COVERPAGE the user can add other information to the information output by ALV (selection information, list status) at this event.
    FOREIGN_TOP_OF_PAGE no USING parameter
    The Top-of-page event is always processed in ALV and is only passed to the caller via the Callback mechanism. This is still the case if the caller, e.g. by a user action, processes a branch list which was not formatted by ALV (e.g. a popup with additional information about the list record selected and displayed by ALV).
    In this case, top-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event top-of-page still occurs in ALV. When ALV notices a top-of-page which was not caused by an ALV output, the form routine in FOREIGN_TOP_OF_PAGE is called.
    FOREIGN_END_OF_PAGE no USING parameter
    The event end-of-page is always processed in ALV and only passed to the caller via callback. This is still the case, e.g. when the caller processes a details list which was not formatted by ALV (e.g. a popup with further information about selected list records which were displayed by ALV).
    In this case, end-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event end-of-page still occurs in ALV. When ALV notices an end-of-page that was not caused by an ALV output, the form routine in FOREIGN_END_OF_PAGE is called.
    BEFORE_LINE_OUTPUT USING RS_LINEINFO TYPE SLIS_LINEINFO
    Output information before each output line. Should only be used in justified cases because it costs a lot of performance.
    AFTER_LINE_OUTPUT USING RS_LINEINFO TYPE SLIS_LINEINFO
    Output information after each output line. Should only be used in justified cases because it costs a lot of performance.
    • Internal use only
    LIST_MODIFY USING R_TABNAME TYPE SLIS_TABNAME
    R_INDEX LIKE SY-TABIX
    R_INDEX_ITEM LIKE SY-TABIX
    R_INDEX_SUM LIKE SY-TABIX
    • IT_EVENTS-FORM
    Name of the form routine which should be called in the calling program at the event.
    Field_catalog:
    Field catalog with field descriptions
    2.7.1. Description
    Field catalog containing descriptions of the list output fields (usually a subset of the internal output table fields). A field catalog is required for every ALV list output.
    The field catalog for the output table is built-up in the caller's coding. The build-up can be completely or partially automated by calling the REUSE_ALV_FIELDCATALOG_MERGE module
    See also the documentation of the function module REUSE_ALV_FIELDCATALOG_MERGE.
    The minimal field catalog is documented under 'default'. The caller can use the other optional parameters to assign output attributes to a field which differ from the default.
    A field catalog need not be built-up and passed explicitly only under the following conditions:
    • The internal table to be output has the same structure as a Data Dictionary structure which is referred to in the internal table declaration using LIKE or INCLUDE STRUCTURE.
    • all fields in this structure are to be output
    • the structure name is passed to ALV in the parameter I_STRUCTURE_NAME.
    See also the documentation of the IMPORTING paramter I_STRUCTURE_NAME.
    Positioning
    • row_pos (row position)
    value set: 0, 1 - 3
    Only relevant if the list output is to be multi-line (two or three lines) by default.
    A multi-line list can also be defined by the user interactively if the default list is one-line.
    The parameter specifies the relative output line of the column in a multi-line list.
    • col_pos (column position)
    value set: 0, 1 - 60
    only relevant when the default relative column positions differ from the field catalog field sequence. The parameter specifies the relative column position of the field in the list output. The column order can be changed interactively by the user. If this parameter is initial for all field catalog entries, columns appear in the field catalog field sequence.
    Identification
    • fieldname (field name)
    value set: internal output table field name (required parameter)
    Name of the internal output table field which is described by this field catalog entry
    • tabname (internal output table)
    value set: SPACE, internal output table name
    This parameter is used in 'manual' field catalog build-up only for hierarchical-sequential lists.
    Name of the internal output table which contains the field FIELDCAT-FIELDNAME.
    Data Dictionary reference
    • ref_fieldname (reference field name)
    value set: SPACE, Data Dictionary field name
    Name of the Data Dictionary field referred to.
    This parameter is only used when the internal output table field described by the current field catalog entry has a reference to the Data Dictionary (not a program field), and the field name in the internal output table is different from the name of the field in the Data Dictionary. If the field names are identical, naming the Data Dictionary structure or table in the FIELDCAT-REF_TABNAME parameter is sufficient.
    • ref_tabname (reference table/structure field name)
    value set: SPACE, name of a Data Dictionary structure or table
    Structure or table name of the referred Data Dictionary field.
    This parameter is only used when the internal output table field described by the current field catalog entry has a Data Dictionary reference (not a program field).
    Reference to fields with currency/measurement unit
    Each internal output table sum or quantity field whose decimal places are to be formatted appropriately for the unit in the list must follow the convention:
    • the field is of data type QUAN or CURR (internal type P) (the field must really have this physical data type. Overwriting the physical data type with the parameter FIELDCAT-DATATYPE has no effect)
    • There is a field in the internal output table which contains the associated unit.
    • There is also an entry in the field catalog for the unit field.
    (If the unit is not to appear as a column in the list, and cannot be interactively displayed as a column, e.g. because it is always unambiguous and is therefore explicitly output by the caller in the list header, the field catalog units field entry can take the parameter FIELDCAT-TECH = 'X'.
    The association of a value field to a unit affects the output as follows:
    • appropriate decimal places display for the unit
    • an initialized field with a link to a non-initial unit is output as '0' for the unit (if FIELDCAT-NO_ZERO is initial). When this field is summed, this unit affects whether the units are homogeneous.
    • an initialized field with a link to an initial unit is output as SPACE. When this field is summed, the unit SPACE does not affect the homogeneity of the units.
    • When non-initial fields with an initial unit are summed, the unit SPACE is considered to be a unit.
    Link to currency unit
    • cfieldname (currency unit field name)
    value set: SPACE, output table field name
    Only relevant for amount columns with associated unit.
    Name of the internal output table field containing the currency unit associated with the amount field FIELDCAT-FIELDNAME. The field in FIELDCAT-CFIELDNAME must have its own field catalog entry.
    • ctabname (internal currency unit field output table)
    value set: SPACE, output table field name
    only relevant for hierarchical-sequential lists
    Name of the internal output table containing the FIELDCAT-CFIELDNAME field.
    Link to measurement unit
    • qfieldname (measurement unit field name)
    value set: SPACE, output table field name
    only relevant for quantity columns with unit link.
    Name of the internal output table field containing the measurement unit associated with the quantity field FIELDCAT-FIELDNAME.
    The field in FIELDCAT-QFIELDNAME must have its own field catalog entry.
    • qtabname (internal measurement unit field output table)
    value set: SPACE, output table field name
    only relevant for hierarchical-sequential lists
    Name of the internal output table containing the FIELDCAT-QFIELDNAME field.
    Column output options
    • outputlen (column width)
    value set: 0 (initial), n
    For fields with a Data Dictionary link this parameter can be left initial.
    For fields without a Data Dictionary link (program field) the parameter must be given the value of the desired field list output length (column width).
    initial = column width is the output length of the referred Data Dictionary field (domain).
    n = column width is n characters
    • key (key column)
    value set: SPACE, 'X' 'X' = kex field (key field output in color)
    Key fields can not be interactively hidden. Parameter FIELDCAT-NO_OUT must be left initial.
    For exceptions see the documentation of the FIELDCAT-KEY_SEL parameter.
    • key_sel (hideable key column)
    value set: SPACE, 'X'
    only relevant when FIELDCAT-KEY = 'X'
    Key field which can be hidden interactively.
    The key column sequence cannot be changed interactively by the user.
    The output is controlled by the FIELDCAT-NO_OUT parameter analogously to non-key fields.
    • no_out (field in field list)
    value set: SPACE, 'X' 'X' = field is not displayed in the current list.
    The user can interactively choose the field for output from the field list.
    The user can display the contents of these fields at line level using the 'Detail' function.
    See also the 'Detail screen' documentation of the parameter IS_LAYOUT.
    • tech (technical field)
    value set: SPACE, 'X' 'X' = technical field
    Field cannot be output in the list and cannot be displayed interactively.
    Field can only be used in the field catalog (not in IT_SORT, ...).
    • emphasize (highlight columns in color)
    value set: SPACE, 'X' or 'Cxyz' (x:'1'-'9'; y,z: '0'=off '1'=on)
    'X' = column is colored with the default column highlight color.
    'Cxyz' = column is colored with a coded color:
    • C: Color (coding must begin with C)
    • x: color number
    • y: bold
    • z: inverse
    • hotspot (column as hotspot)
    value set: SPACE, 'X'
    'X' = column cells are output as hotspots
    • fix_column (fix column)
    value set: SPACE, 'X'
    Not relevant for block lists (output of several lists consecutively)
    'X' = column fixed (does not scroll horizontally)
    All columns to be fixed must have this flag, starting from the left. If a column without this flag is output, only the columns to the left of this column are fixed. The user can change the column fixing interactively. See also the documentation of the Layout parameter
    IS_LAYOUT-NO_KEYFIX of the IMPORTING paramter IS_LAYOUT.
    • do_sum (sum over column)
    value set: SPACE, 'X' 'X' = a sum is to be calculated over this internal output table field.
    This function can also be called by the user interactively.
    • no_sum (sums forbidden)
    value set: SPACE, 'X' 'X' = no sum can be calculated over this field, although the data type of the field would allow summing.
    • input (column ready for input)
    Function not available
    Format column contents
    • icon
    value set: SPACE, 'X' 'X' = column contents to be output as an icon.
    The caller must consider the printability of icons.
    • symbol
    value set: SPACE, 'X' 'X' = column contents are to be output as a symbol.
    The internal output table column must be a valid symbol character.
    The caller must consider the printability of symbols.
    Symbols can usually be printed, but may not always be output correctly, depending on the printer configuration.
    • just (justification)
    value set: SPACE, 'R', 'L', 'C'
    Only relevant for fields of data type CHAR or NUMC
    ' ' = default justification for this data type
    'R' = right-justified output
    'L' = left-justified output
    'C' = centered output
    The justification of the column header always follows the justification of the columns. Independent justification of the column neader is not possible.
    • lzero (leading zeros)
    value set: SPACE, 'X'
    Only relevant for fields of data type NUMC
    ALV outputs NUMC fields right-justified without leading zeros by default.
    'X' = output with leading zeros
    Note: If a NUMC field is output left-justified or centered by FIELDCAT-JUST, leading zeros are output. If the output of leading zeros is suppressed by a Data Dictionary reference ALPHA conversion exit, the output is always left-justified.
    • no_sign (no +/- sign) Only relevant for value fields
    value set: SPACE, 'X' 'X' = value output without +/ sign
    • no_zero (suppress zeros) Only relevant for value fields
    value set: SPACE, 'X' 'X' = suppress zeros
    • edit_mask (field formatting)
    value set: SPACE, template
    template = see documentation of WRITE formatting option USING EDIT MASK template
    The output conversion conv can be made by template = '== conv'.
    Texts
    The following text parameters should be specified for program fields without a Data Dictionary reference. The texts are taken from the Data Dictionary for fields with a Data Dictionary reference. If this is not desired, the text parameters can also be specified. The Data Dictionary texts are then ignored. If the user changes the column width interactively, the column header text with the appropriate length is always used. The interactive function 'Optimize column width' takes account of both the field contents and the column headers: if all field contents are shorter than the shortest column header, the column width depends on the column header.
    The 'long field label' is also used in display variant definition, sort, etc. popups.
    • seltext_l (long field label)
    • seltext_m (medium field label)
    • seltext_s (short field label)
    • reptext_ddic (header)
    analogous to the Data element maintenance 'Header'
    The specified text is not necessarily output in the list, an optimum among all texts is sought.
    • ddictxt (specify text)
    value set: SPACE, 'L', 'M', 'S'
    You can specify with values 'L', 'M', and 'S', the keyword that should always be used as column header. If the column width changes, no attempt is made in this case to find an appropriate header for the new output width.
    Parameters for program fields without Data Dictionary reference
    see also 'Text' parameters
    • datatype (data type)
    value set: SPACE, Data Dictionary data type (CHAR, NUMC,...)
    Only relevant for fields without Data Dictionary reference
    Program field data type
    • ddic_outputlen (external output length)
    value set: 0 (initial), n
    Only relevant for fields without Data Dictionary reference whose output is nevertheless to be modified by a conversion exit.
    Prerequisites:
    • FIELDCAT-EDIT_MASK = '==conv'
    see also the documentation of the parameter FIELDCAT-EDIT_MASK
    • FIELDCAT-INTLEN = n
    see also the documentation of the parameter FIELDCAT-INTLEN
    n = external format field output length
    The column width FIELDCAT-OUTPUTLEN need not be the same as the external format output length (FIELDCAT-DDIC_OUTPUTLEN).
    • intlen (internal output length)
    value set: 0 (initial), n
    Only relevant for fields without Data Dictionary reference whose output is nevertheless to be modified by a conversion exit.
    Prerequisites:
    • FIELDCAT-EDIT_MASK = '==conv'
    see also the documentation of the parameter FIELDCAT-EDIT_MASK
    • FIELDCAT-DDIC_OUTPUTLEN = n
    see also the documentation of the parameter FIELDCAT-DDIC_OUTPUTLEN
    n = internal format field output length
    • rollname (data element)
    value set: SPACE, Data Dictionary data element name
    F1 help can be provided for a program field without a Data Dictionary reference, or F1 help which differs from the Data Dictionary help can be provided for a field with a Data Dictionary reference, using this parameter.
    When F1 help is called for this field, the documentation of the specified data element is displayed.
    If the FIELDCAT-ROLLNAME is initial for fields with a Data Dictionary reference, the documentation of the data element of the referred Data Dictionary field is output.
    Others
    • sp_group (field group key)
    value set: SPACE, CHAR(1)
    Field group key.
    Keys are assigned to group names in the IT_SPECIAL_GROUPS parameter (see also the documentation of the parameter IT_SPECIAL_GROUPS).
    When such an assignment is made in the field catalog and in IT_SPECIAL_GROUPS, the fields are grouped correspondingly in the display variant popup.
    • reprep (Report/Report interface selection criterion)
    value set: SPACE, 'X'
    Prerequisites:
    • The system contains the Report/Report interface (function group RSTI, table TRSTI)
    • Parameter LAYOUT-REPREP = 'X'
    (see also the documentation of the parameter LAYOUT-REPREP of the IMPORTING parameter IS_LAYOUT )
    'X' = When the Report/Report interface is called, the value of this field is passed in the selected interface start record as a selection criterion.
    2.7.2. Default
    • The following entries are usually sufficient for internal table fields with a reference to a field defined in the Data Dictionary :
    • fieldname
    • ref_tabname
    Notes:
    ALV gets the remaining information from the Data Dictionary.
    If no relative column position (COL_POS) is specified, the fields are output in the list in the order in which they were added to the field catalog.
    REF_FIELDNAME need only be specifid when the name of the internal table field differs from the name of the referred Data Dictionary field.
    Information which is explicitly entered in the field catalog is not overwritten by information from the Data Dictionary.
    Priority rule:
    Entries in the field catalog have priority over differing entries in the Data Dictionary.
    • The following entries are usually sufficient for internal table fields without a reference to the Data Dictionary (program fields):
    • fieldname
    • outputlen
    • datatype
    • seltext_s
    • seltext_m
    • seltext_l
    Notes:
    F1 help can be provided for program fields by assigning a data element to the parameter ROLLNAME.
    If the parameters SELTEXT_S, SELTEXT_M, SELTEXT_L, and REPTEXT_DDIC contain appropriate field labels, the program field column headers are also adjusted appropriately when the column width changes
    sites :
    http://www.sapdevelopment.co.uk/reporting/alv/alv_variousfcat.htm
    <b>plese reward if useful </b>
    Message was edited by:
            sunil kairam

  • Error while creating import parameters in RFC function module

    Hi,
    I am trying to create import parameter in RFC enabled function module and getting the following error "Reference parameters are not allowed with RFC". Am I doing something wrong.
    Your earlier response is much appreciated
    Regards
    Kasi

    There is a "Pass by Value" checkbox, just check that and you wont get the error.  The basic reason behind is since an RFC is called by a different system the parameters have to be sent as values than as references.
    hith
    Sunil Achyut

  • Get Import Parameters of a Function Module

    Hi,
    Is there a way to find the import parameters and their Data Type of a Function Module in any Table??
    For example, i know i can find the name and the include of the Funtion Module in TFDIR. Is there anywhere i can find the list of Import Parameters and their Data Types??
    Thanks and Regards,
    Kaeyur

    you can use
    Data: lv_type type c.
    clear:lv_type.
    DESCRIBE FIELD p_bukrs TYPE lv_type.
    It will return C as its type C and p_bukrs is selection screen parameter.
    hope this helps.

  • Doubt in  export, import and table para when creating Function Module

    Dear fellow ABAPers,
    I have a doubt in defining export, import and table parameter while creating a function module.
    I am calling a function module inside a user exit. Now in the user exit the SAP fills an internal table called i_lfa1 with all the data user has eneterd.
    Now I want to pass this whole internal table to function module and the perform some checks on the values of internal table.
    After that function module fills an error structure with values depending on some check.
    1)
    How do I pass this internal table to function module ? 
    When I am creating function module in se37 where do I define this iternal table type ? Is it in Import or Table parameter during function module creation?
    2)
    Where do I define error structure type (which is returned by function module to main program)? Is it in Export or table parameter during function module creation?
    Please clear my doubt..
    Relevant points will be awarded.
    Regards,
    Tushar.

    Hi Tushar,
    1. How do I pass this internal table to function module ?
       I assume u are creating your own Y/Z FM.
       Pass it thru TABLES parameter.
    2. When I am creating function module in se37 where do I define this iternal table type
       Define this in TABLES interface.
       What Type ?
       THE SAME TYPE WHICH HAS BEEN DEFINED
        WHILE PASSING IN THE USER-EXIT FUNCTION MODULE.
       IF U SEE THE FM OF THE USER-EXIT,
       U WILL COME TO KNOW.
    3.
    Where do I define error structure type (which is returned by function module to main program)? Is it in Export or table parameter during function module creation?
    Define it in TABLES interace. (not in export, import)
      (Since what u are going to return is an internal table)
      U can take for eg. BDCMSGCOLL.
      OR u can create your own Y/Z structure
    for the same purpose.
      (or u can use the structure type T100)
    I hope it helps.
    Regards,
    Amit M.

  • How to use select-options in the function module of import parameter ?

    Hi ...
       I have created a BAPI and tested in SWO1 tcode , by giving the single value for an company code ( BUKRS ) , it executed properly .
    Same thing is working after implementing in a program .
    so now it is working for fetching a single company code details .
    My requirement is : I want to use select-options in program as well as in function module IN IMPORT PARAMETER.
    Program :
    REPORT  ZTEST.
    TABLES : T001 , ZBAPI_STR .
    TYPES : BEGIN OF TY_ITEM  .
              INCLUDE STRUCTURE ZBAPI_STR .
    TYPES : END OF TY_ITEM .
    DATA :WA_ITEM TYPE TY_ITEM ,
          ITEM LIKE STANDARD TABLE OF WA_ITEM INITIAL SIZE 0 .
    PARAMETER : BUKRS TYPE ZBAPI_STR-BUKRS.
    call function 'ZBAPI_FMT001'
      exporting
        bukrs         =  BUKRS
    IMPORTING
      RETURN        =
      tables
        itemtab       = ITEM
    IF ITEM IS NOT INITIAL .
      LOOP AT ITEM INTO WA_ITEM .
        WRITE : / WA_ITEM-BUKRS , WA_ITEM-BUTXT , WA_ITEM-ORT01 , WA_ITEM-LAND1 .
      ENDLOOP.
    ENDIF.
    FUNCTION MODULE :
    FUNCTION ZBAPI_FMT001.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(BUKRS) TYPE  EFG_TAB_RANGES
    *"  EXPORTING
    *"     VALUE(RETURN) TYPE  BAPIRET2
    *"  TABLES
    *"      ITEMTAB STRUCTURE  ZBAPI_STR
    SELECT BUKRS BUTXT ORT01 LAND1 FROM T001 INTO TABLE ITEMTAB WHERE BUKRS = BUKRS .
    ENDFUNCTION.
    Regards
    Deepa.

    I have given a similiar example which i did
    Declare a
    Table type:Z_TT_PONUM             
    Short text  :  Select options  PO Number
    in SE11 tcode with row type eg: Z_ST_PONUM
    create a structure (this will be the row type)
    Structure          Z_ST_PONUM            
    Short text         Select Options Field PO number
    Compenent  Compent type
    SIGN       BAPISIGN      Inclusion/exclusion criterion SIGN for range tables
    OPTION       BAPIOPTION      Selection operator OPTION for range tables
    LOW       EBELN                      Purchasing Document Number
    HIGH       EBELN                      Purchasing Document Number
    In the function module import
    give as
    I_PO_NUM     TYPE     Z_TT_PONUM     opt  pass value Select options  PO Number
    Hope this is exactly what you want to know.
    So you create a structure simliar to mine but the low an high whould be your component
    then a table type  and then include that in the BAPI.
    Then pass your select-option value to this BAPI when you call this BAPI in the program

  • How to import a range in Function module?

    I am using a Function module in which material is getting imported.
    In the import tab we have
    Parameter Name    Typing     Associated Type       optional          pass value
    IM_MATERIAL       TYPE       MATNR                 <checked>         <checked>
    So when the Function module is execute we can enter only one value into the IM_MATERIAL.
    But now it has to be enhanced for entering multiple values. How to import the material as a range?
    Please throw light.
    Thanks.

    Hi
    If you are using a select-options you can use this approach.
    TABLES: MARA.
    DATA: RANGE TYPE WRF_MATNR_RANG_TTY.
    SELECT-OPTIONS: SO_MATNR FOR MARA-MATNR.
    START-OF-SELECTION.
      RANGE[] = SO_MATNR[].
    CALL FUNCTION 'ZTEST'
    EXPORTING
       I_RANGE       = RANGE.
    Where I_RANGE is defined using this table type WRF_MATNR_RANG_TTY
    Parameter Name    Typing     Associated Type     optional          pass value
    I_RANGE       TYPE       WRF_MATNR_RANG_TTY      <checked>     <checked>

  • RFC function module with call transaction  and Import memory ID

    Hi,
    I am calling RFC function module from R/3 which exists in BW.
    In BW stand alone function module works fine.
    When I am Calling from R/3 it is not working,
    Can you tell me is it because of the below code, And suggest if any corrections required.
    I am calling the call transaction and using EXPORT memory iD inside the program
    and IMPORT in after that.
    And populating RFC table's table  " p_i_tcode_user" finally.
    set parameter id 'TCD' field p_tcode.
    call transaction 'Z_BW_RSUSR002' AND SKIP FIRST SCREEN.
      ENDIF.
    get the final user data from submitted program
    import gt_users_complete from memory id tcode_userid.
    LOOP AT gt_users_complete.
          lwa_tcode_user-tcode =  p_tcode.
          lwa_tcode_user-uname = gt_users_complete-Bname.
          APPEND lwa_tcode_user TO p_i_tcode_user.
    ENDLOOP.
    Thanks,
    Veerendra.

    HI,
       Can you just exaplin it clearly plz..
    Thanks
    Mahesh

  • Any example to import and export itab to function module

    hi all,
    as the table parameter in function module is obsolete, please advise an example on how to pass in an internal table
    and return back the result in an internal table as well.
    for example, i have itab1 and itab2. By using table parameters i got the following code. Please advise alternative way by using import and export.
    ""Local Interface:
    *"  TABLES
    *"      itab1 STRUCTURE  Zitab1
    *"      itab2 STRUCTURE  Zitab2
    loop at itab1 into wa_itab.
    **do some logic here to assign value to itab2 and return.
      wa_itab2-a = xxx .
      wa_itab2-b = xxx.
    append wa_itab2 to itab2.
    endloop.
    thank you.

    hi,
    suppose you have two structure name struc1 and struc2.
    create table type zitab1 & 2 for both.
    please do the following:
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(itab1) TYPE  Zitab1
    *"  EXPORTING
    *"     VALUE(itab2) TYPE  Zitab2
    you can avoid to use the obsolete table parameters as well as LIKE in function module creation.
    cheers

  • Function module import parameter

    I had used a bapi in the program and i got a dump.
    then i recetified the dump. But kindly tell me the
    reason .
    My program is like this..
    Report xyz.
    DATA wa_bapireturn TYPE bapireturn.
    DATA it_bapireturn LIKE TABLE OF  wa_bapireturn.
    DATA wa_bapisdstat TYPE bapisdstat.
    DATA it_bapisdstat LIKE TABLE OF  wa_bapisdstat.
    PARAMETERS p_vbeln LIKE vbap-vbeln.
    START-OF-SELECTION.
      CALL FUNCTION 'BAPI_SALESORDER_GETSTATUS'
        EXPORTING
          salesdocument = so_vbeln
        IMPORTING
          return        = it_bapireturn
        TABLES
          statusinfo    = it_bapisdstat.
    now i got the dump because i have used
    it_bapireturn for importing.
    then i modified the program like..
    CALL FUNCTION 'BAPI_SALESORDER_GETSTATUS'
        EXPORTING
          salesdocument = so_vbeln
        IMPORTING
          return        = wa_bapireturn
        TABLES
          statusinfo    = it_bapisdstat.
    Now the program working fine because i passed
    wa_bapireturn. please tell me why it happened like
    this. How to know when to pass internal table and when to
    pass just a structure.
    And also tell me the difference bet type and type ref to.

    As per the interface definition of the BAPI, it expects one workarea in the RETURN parameter.
    but it_bapireturn was an internal table so was the dump
    but wa_bapireturn is a work area so it worked.
    You can check the interface of the Function Module to know what to be used. Usually work areas are passed in IMPORT AND EXPORT parameters and internal tables in TABLES parameters.
    by using TYPE , we create a variable of a pre difined TYPE.
    by using TYPE REF we create object of a particual class
    Edited by: Swastik Bharati on Aug 21, 2008 2:16 PM

Maybe you are looking for

  • How do I call a Mac computer with Face Time from my iPhone 4?

    I just upgraded my iMac to OS X Lion and I now have Face Time on my desktop computer. I figured out how to MAKE a call from my desktop to someone's iPhone. But, I can't figure out how to call my desktop computer FROM my iPhone 4? I tapped the phone i

  • Error while changing the Display Attribute into Navigational Attribute

    Hi all.. Gud Mrng. I was changed the attribute (product) from display attribute into navigational attribute and while save and activating the info object it is not getting activated and it is throwing the below error message. Error Message: u201CThe

  • Automatic creation AUC sub assets at the time of settlement

    Hi, I have created the investment profile,AUC asset class,Source structuce(Hard,Pave and Soft) and cost element group(Hard,Pave and soft) . Then assign these three source structure to Investment profile. I created WBS element under project and releas

  • What characters are allowed in an Apple ID Password?

    My mom has "changed" her password because she said she was asked to when logging into Facetime. Now she can't log in. When I asked her what it was, she read to me and it had both a space and a period. I don't believe those are accepted. I tried to lo

  • IWeb Site, GoDaddy hosting

    Been having major problems with GoDaddy, anybody had trouble with them They are driving me nuts, It took 5 days of emails just to get the site up, then two JS slideshows can't be found, the problem is on-going! Anyone?