In function palette-instrument I/O i have lost library:INSTR LIB

when i clik on instrument I/O in the function palette, inside i have this library:GPIB,SERIAL,VISA,I/O COMPATIBILIY but i lost library INSTR LIB.
In directory c:\programmi\national instrument\labview6\instr lib there are all my driver instrument
haw can i view this driver in function palette\instrumet i/O ?

Here is a great document that has instructions how to add a palette.
How Do I Create a Custom Sub-Palette in the Functions Palette in LabVIEW 6i and Above?
If this doesn't work, try reinstalling LabVIEW.
Zvezdana S.

Similar Messages

  • Serial PDA function sub palette missing from Functions Palette in PDA Module 8.0

    Hi:
    I have a problem that I would like to solve without having to reinstall PDA module.  Under the functions palette, Instrument I/O ... I have the Serial Compatability sub palette there but the VISA and the Serial ones are now questions marks instead of a sub palette.  Has anyone had this problem and if so how is it fixed.   If I copy and paste the VI's from Labview 8.0 (for PC) to the PDA vi I'm writing, they seem to work fine but what a pain that is ... anyone have an suggestions?  Thanks
    Greycat

    Hello Greycat,
    The subpalettes for the VISA and Serial subVIs are suppose to be
    unavailable if your target is a PDA device.  LabVIEW loads a
    seperate palette set for each target.  Since VISA is currently not
    supported on the PDA, you cannot directly open the the VISA functions
    or the Serial functions when you are targeting a PDA device. 
    Instead, you can use the Serial Compatibility VIs, which then call the
    appropriate VISA calls.
    Hope
    Wendy L
    LabWindows/CVI Developer Newsletter - ni.com/cvinews

  • Why does LabVIEW for Lego Mindstorms have 2 Functions Palettes?

    LabVIEW for Lego Mindstorms has 2 separate Functions Palettes.  One of them appears when one creates a VI (.vi) for a Project (.lvrbt), and it appears to contain Mindstorms NXT functions.  The other appears when one creates a stand alone VI (.vi), and it contains functions which are labelled "NXT Robotics" but which appear to be the old Mindstorms RCX functions.  For example, the Motor Functions have no Speed or Duration controls.  (See Control Palette pictures on the attached Word document.)  (NI should be aware that the RCX is no longer sold or supported by Lego.)
    If I only want to create a stand-alone VI, how do I access mature NXT functions with which to implement that VI?
    Attachments:
    NI LabVIEW Function Palettes.doc ‏127 KB

    I knew that the NXT could be controlled from a "remote" device (e.g. cell phone), though perhaps "remote" is a poor choice of words given your use of the word "direct" which, as you use it, has the same connotation.  I have never run the NXT in the direct mode, nor have any of my team members.  The reason I assumed that you had included RCX functions was RCX functions had fewer properties than NXT functions just like your "direct" functions do.  I have no idea where the "dual mode" functions are to be found.
    I think LVLM has inadequate introductory documentation.I have Gasperi's book, but like NXT-G books, he only gives recipes for robots with different functionalities.  LVLM needs a better structural and functional description.
    Lego Education is not supporting LVLM (nore is NI, for that matter, at least not very well...it was a lot of work to get to someone who knew what they were talking about).  The guys at Lego Education are not in a position to support LVLM.  Your guys also asked me to call "Tom Barrowman," Lego's New England sales rep.  I didn't call him, but I am betting that he knows even less.
    I understand why NI doesn't want to put the support bucks into LVLM.  The license for LV cost $2500/year, and I bought LVLM for $100.  LVLM was intended to be an introductory product for people (kids) who might become NI customers someday, but if those kids walk off in disgust because they can't figure out how to use LVLM, NI's investment in it will have been for nothing.
    Attachments:
    For Ethan.doc ‏66 KB

  • Populating the Signal Express Category on the Functions Palette

    Hi
    Can anybody help with advice on how to populate the signal express category on the block diagram Functions palette ?
    Thanks
    Solved!
    Go to Solution.
    Attachments:
    LV Functions Palette.PNG ‏14 KB

    Hi Ewan,
    Uninstalling and reinstalling in the right order would ensure that everything was properly associated. However, I don't think that should be necessary yet in your situation. Please go to Control Panel > Programs and Features > National Instruments Software to see the full list of National Instruments software you have installed. From here you should be able to select any individual installation from the list and select "Repair". Instead of just seeing that something is already installed and exiting, this should go through the installation and check for corruption. As well, this should add the correct associations if they were currently missed due to the order of installation. 
    Please try running a repair of SignalExpress 2013 and restarting your computer, then check to see if the functions palette in LabVIEW is fully populated.
    Thanks!
    Emily C
    Applications Engineer
    National Instruments

  • Function palette off screen

    My function palette was moved on to a secondary monitor. I no longer have that monitor and cannot see the functions palette. I've gone in to the labview.ini file (in the Program Files/National Instruments/Labview 2011 directory)  but cannot find an entry that sets the function palette position. I did see in another post  that there was supposed to be such an entry for the tool palette, but can't find that either) How can I get the function palette back on screen?

    Off-hand I'm not sure, but in the interim you can just right-click on the BD and pin the resulting palette.  I think the old one will still be off screen, but at least you'll have something to work with.
    Bill
    (Mid-Level minion.)
    My support system ensures that I don't look totally incompetent.
    Proud to say that I've progressed beyond knowing just enough to be dangerous. I now know enough to know that I have no clue about anything at all.

  • "dir.mnu warning" after editing the function palette

    Hello everybody!
    I´ve got a small problem, which is getting on my nerves! I created a new subfolder with vi´s in the function-palette (with the advanced palette tool)... after all i deleted it, because now i use other vi´s. So the problem is everytime i open a vi of my project which has something to do with the "signal processing palette", i got this warning that the "dir.mnu" has changed.
    So far i created a new project, but the problem is still there... How can i restore the default palette settings? Can i delete the false dependencies? Or are there global files i can delete and then labview uses the default palette?
    Thanks,
    Michael
    Attachments:
    warning.JPG ‏28 KB

    I think when i installed Labview, there was a symbol for every VI in the function-palette. Could it be that i somehow have overwitten the defaults in the ...\National Instruments\LabVIEW 2009\menus folder? So thats why the "restore defaults" button is grayed out, because these ARE the default values. Is it possible to get the "dir.mnu" for the signal processing subpalette (...\National Instruments\LabVIEW 2009\menus\Categories\Signal Processing\dir.mnu) of somebody?... Reinstalltation is al little more complicated, because the DVDs are at our computer administrative department.
    So, thanks for your help....
    Michael
    Attachments:
    palette.JPG ‏37 KB

  • Can't find NXT functions in Function Palette

    I'm trying to setup the NXT Toolkit in LabVIEW 8.2. I downloaded it, installed it, and then mass compiled with no error. When I start up LabView, I have everything I'm supposed to (for example the Tools->NXTModule menu option) but no new functions in the function palette. According to the getting started guide, I should have lots of NXT commands but I can't see any of them. What am I doing wrong?
     I've attached an image of my function palette to show you where I'm looking
    >

    Hi, Squirell!
    Thanks for the additional information! Looks as if everything should work fine...
    You could check the file system: In your LabVIEW folder (e.g. C:\Programs\National Instruments\LabVIEW 8.2) you will find a subfolder vi.lib. Inside that folder, you find the subfolder "addons" - that's where the toolkit gets installed, so you should find as next level subfolders "NXTToolkitDirectCommands" and "NXTToolkit". (...\LabVIEW 8.2\vi.lib\addons\NXTToolkit). Within "NXTToolkit" there should be another 8 folders plus one file (dir.mnu). Asking the XP explorer about the properties of the folder "NXTToolkit", it gives me as total content 1152 files and 81 folders.  If this is not what you get try to reinstall the NXT toolkit.
    If it's what you get, too, it might have to do with the "Infinity Project" - I have no idea whether NI published a reduced version for it. What you could try in that case: request a LabVIEW 7.1 Student Edition under http://digital.ni.com/express.nsf/bycode/lvtoolkitlego (only be used for software development with LEGO MINDSTORMS NXT) - that version should work without any problems!
    Regards
    Ulf

  • Modify function palette quickly?

    Hi, everyone
    I got a boring question when I modifying the function palette.
    Now I'm developing an instrument driver with LabVIEW7.0.
    I have an old version of its driver, so only I need to do is to update it, as the function palette.
    For example, the prefix of the old version driver is xyz2000, this time I should change it to xyz1000.
    But when I change the folder name to xyz1000(originally is xyz2000) and open the old version driver with LabVIEW,
    the function palette is full of [?]icon.
    Therefore I try to modify the following original xyz2000 mnu files with UE(text editor),
    I simply think if I replace all the [xyz2000] to [xyz1000] is just ok, but I failed.
    I got something like"memory is not enought" error.
    acstat.mnu
    applic.mnu
    config.mnu
    data.mnu
    dir.mnu
    util.mnu
    Does everyone have some ideas how to modify the function palette quickly in my case?
    Cause I think insert all the vis one by one again to function palette is a boring job ^o^, no easier way(just like modify the mnu file)?
    Help me plz, thank you

    This unfortunately doesn't apply to LV7.0, but there was a new feature in LV8.6 (it may have been in 8.5) for editing palettes much more quickly and easily. It was a VI-based set of functions for editing palettes. This would enable you to write a quick utility to manage your palette files and rename things more quickly and easily as you like.
    Message Edited by Jarrod S. on 12-29-2008 11:14 AM
    Jarrod S.
    National Instruments

  • Change Folder Icon in Functions Palette

    Hey, have two questions.  I'm writing an instrument driver for an instrument I have here at work, and I have the VI's working.  I have the VIs organized and inserted into a library, which is in a project including that library and an examples folder (so basically the way Labview downloaded instrument drivers are set up).  I put all this in the instr.lib folder, and the VIs show up in the functions palette just fine.  So, based on that setup, my questions are:
    1) How do I change the folder icons (not the VI Icons - already did that) in the functions palette?
    2) How do LV instrument drivers hide the "Examples" folder and simply display the VIs from the "Public" Folder?  (they don't appear to be marked private)
    Thanks!
    TG
     

    I think the secret is in having an mnu file, which defines what will appear in the palettes. You can create one by editing the palettes (under Tools>>Advanced) and there you should be able to remove items and to edit the palette icon by right clicking it. You should probably also make sure that the mnu file is saved in the same folder, so that you can have it in other PCs. Note that the palette editor has this annoying confirmation dialog which tends to hide under other windows and which you need to get to finish editing, so move it to somewhere you can find it before you start editing.
    Another option is using VIPM to install the driver, and that will also allow you to edit a palette.

  • Image Processing and machine vision don't appear in Function Palette

    Hi,
    I have problem and I can't solve it
    Image Processing and machine vision don't appear in Function Palette, Although I set up NI imaq and NI Vision Acquisition Why??
    Anyone can help me?
    Solved!
    Go to Solution.

    If the image is already a Grayscale U8 image you would just have to save it to a bitmap file using the IMAQ WriteFile VI. If not, use the IMAQ Cast Image VI to convert it to a Grayscale U8 and then save it.
    Also, it would probably be better to create a new thread for questions like these.
    Cameron T
    Applications Engineer
    National Instruments

  • "in port" and "out port" VIs are not in the functions palette!

    Hi,
    I am using LabVIEW 2012 on a Win 7 64 bit. I want to read a digital input (3.5V) using PC parallel port. I also read this white paper:
    http://digital.ni.com/public.nsf/allkb/B937AC4D8664E37886257206000551CB
    I searched all the functions palette for “in port” and “out port” VIs but I could not find them. Apparently they are not supported in 64bit OS. What are my alternatives for reading digital input via PC parallel port?
    Thanks.

    They have not been supported for quite some time. What happens when you use the recommended VISA api?

  • Help on function palet

    I've installed lv6.1 and NI-DAQ 6.xx.xx; when I launch lv on the main window the DAQ wizard is not active can some1 tell me why? On the function palet i don't have the menu of Dat Aquisition why

    This'll show you what to do:
    http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/f7d5934af18eaa038625694600453df2?OpenDocument
    2006 Ultimate LabVIEW G-eek.

  • Where in the function palette can i find the "logical shift" function (shift x by y bits)?

    i am not able to find the "logical shift" function anywhere on the functions palette (after searching EVERY where). however, i discovered the function elsewhere in another VI (by pure luck!). i could keep bringing up these VI and copying and pasting, but that's a pain...i'd like to just have it on my functions palette to begin with.
    i am running labview 6.1 thanks for your help.

    hi,
    LabVIEW's functions pallete has come with a very useful tool --> "Search" tool
    Make use of the "Search" tool should you encounter difficulty in locating the desired function. For instants, search for keyword "Logical" or "Shift" and you will be able to locate the function
    happy coding
    Ian F
    Since LabVIEW 5.1... 7.1.1... 2009, 2010
    依恩与LabVIEW
    LVVILIB.blogspot.com

  • No DMM functions in functions palette

    Good Morning,
    I'm VERY new to labview but I'm starting to get the hang of it. Anyway i've been searching for hours and have been unable to find a solution to my issue.
    I'm running a NI PXIe-1078 chassis with PXIe-8101 controller 
    I'm trying to program data aquisition for my PXI-4071 DMM in my Labview project but there are no functions in the functions palette.
    I installed the NI-DMM 3.0.5 driver and can see the device connected in MAX. I can even use the soft panel and take measurements from the PXI-4071.
    For the other devices i have installing the driver put the functions in the functions palette but for some reason they are all missing for the DMM. 
    I've tried using the DAQmx and searching for an analog input channel but it is not on the list.
    please help!
    Sincerely,
    Michael Reed

    It sounds like a "corrupt" installation of NI DMM (see paragraph below).
    Please note that NI DMM 3.0.5 is out-dated, so you should get a more recent version.
    When installing a new system, NI recommends to start with the developement environments and in the last step to install all desired drivers. Following this ensures that the installer of the drivers can detect the installed ADEs and select to install the APIs for these. If you swap install order, the APIs are not installed with the driver, leaving the ADE blank (no examples, no palettes).
    You can install the APIs in a second iteration, but that is an effort you should only put into the system when installing a new version of an ADE.
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • Functions palette missing icons (Report Gen. Toolkit))

    Os: XP
    Ver. Labview 2010
    Hi all,
    I am having problems with mig functions palette. For the Report Generation Toolkit there are missing icons , subpalettes are empty. I have tried to fix it in 2-3 hours without luck 
    Anyone who knows to how to get the Report Toolkit to ping to the right dir.mnu, llb, and .vi folders?
    Attachments:
    RE1.jpg ‏87 KB

    If i am in edit Controls and Functions Palette  Set, and browsing to Word tabel window which were empty before, its not empty in edit mode. If you go back to normal mode, than they are gone
    Attachments:
    editp.jpg ‏54 KB

Maybe you are looking for

  • How to use one Filter Pane to multiple Dataproviders

    Hi Experts. i have checked the threads on this but i did not get correct solution. we have issue in using single Filter pane web item in WAD for three different dataproviders ( three dataproviders have same free charecteristics and variable) charecte

  • ITunes university subscriptions are duplicating

    I noticed odd behavior yesterday.  iTunes courses to which I've subscribed and fully downloaded are starting to replicate.   The course will be listed twice in the left nav bar, and duplicate classes/documents will download.  This behavior is not con

  • I tried opening my iTunes and it came up with this

    "The iTunes application could not be opened. An unknown error occurred (13014)" I'm not quite sure what do do. Help?

  • Re-building database

    How long should it take? I have this problem.. I bought Zen Sleek last monday and now it jammed (showed boot-logo) and I pressed the magic button on the bottom. Then it wanted to re-build database, which seems to take forever. It has now been idling

  • Shockwave content loading

    I've built a shockwave presentation that is made up of a number of movies, external cast cst files and even an externally linked JPG image as my background image. I'd like some advice on how I should set up my shared components so that they load up i