IN ODS Object Manage tab?

hello all
In ods object manage tab in "<b>REQUEST</b>" tab there are options like <b>request</b>,<b>data mart status of the request,PSA ID request is generated with Activation,Technical Status</b> and so on?
what do v mean by this?
1.data mart status of the request(when this will generate)
2.PSA ID request is generated with Activation(when this will generate)and
3.Technical Status
many thanks
balaji

hi AHP
thanks for given info., but in that link  I could'nt able to get info regarding this can u tell why this is needed  "<b>PSA ID REQUEST IS GENERATED WITH ACTIVATION</b>"
and "<b>TECHNICAL STATUS</b>".
many thanks
balaji

Similar Messages

  • ODS activation error"Activation of data records from ODS object terminated"

    Hi All,
    While activating ODS request I am getting following error
    "Activation of data records from ODS object KFI02O50 terminated ".
    data load is suceesful for ODS but during activation of the request it is giving error.
    I tried to change the status to green manually & then activated the request but still same problem.
    Also I tried to delete request & loaded again from PSA & then activated the request but still same problem
    If anybody has some solution please let me know.
    Thanks in advance
    Regards
    Sonal

    Hi Sonal,
              Sometimes when there is erroeneous records that time while activating the Request request get fails.To check this go to manage tab of the ODS there under log u can see the log icon click on that and check y activation got failed..
    Assign points if its helpful
    Regards,
    vid.

  • Unable to find the master data loaded request in manage tab

    Hi All,
    Iam unable to see the loaded request in the master data manage tab after some time of loading.
    Immediately after loading i could see the request.If i revisit the manage tab,iam unable to see the request.
    However data is available for the info object .
    Can anyone please suggest on this.
    Regards,
    Kavya

    hi Devupalli,
    Note your request number, find it using RSRQ tcode. Now click on the target icon and see if it takes you to the manage of your infoobject.
    There is a very common error which we sometimes make: are u sure you're checking the right thing? please check that if your infoobject has text, attribute and hierarchy, you're checking in the manage of the relevant one.
    For ex, if you're loading text, you have to go to manage of the text.
    Hope this helps!
    Sheen

  • Error activating ODS object.

    Hi Experts,
    None of the ODS objects gets activated and following are the error messages that i get when i try to activate a ODS object :
    Object ZRSMODS could not be activated
    <b>
    "</b>
    Message no. R7I028
    Transfer structure prefix for source system T90CLNT090 is not defined
    Message no. RSAR325
    Diagnosis
    A prefix is defined for the source system for determining cross-system unique transfer structure names. This prefix is not defined between your source system T90CLNT090 and Warehouse T90CLNT090. There was probably an error when creating the source system.
    Procedure
    If you have not yet loaded data from this source system, delete the source system and then recreate it.
    If the problem occurs again, check the SAP Support Portal. Create a new problem message, if necessary.
    Error when creating the export DataSource and dependent Objects
    Message no. RSDODSO169
    <b>"</b>                                                                               
    Pls send a solution asap. Thank you for the same.

    Hi Aravind,
    Have a look on the following points and see if they are satisfied in your case:
    Check all characteristics involved as described below:
    1. Check the Compounding and Attributes tabs in the characteristics maintenance.
    2. All characteristics here must be active. This is displayed by a green icon.
    If this is not the case for a characteristic involved (a gray icon is displayed on one of the two tabs), activate the characteristic involved. This also activates the inactive dependent characteristics.
    3. After you have checked and repaired all the characteristics involved as described above, the loading/maintenance of master data should work again.
    Because of this you may sometimes get the same error while activating the ODS object.
    Hope it helps...
    Best Regards,
    DMK
    *Assign points if it helps...

  • Error while loading data to ods object from flatfile

    hello all
    Iam loading data from flatfile to ods object and the processing type is PSA and then to data target(package by package),data arrived in PSA(its green) but in monitor the request is in red and in details tab of <b>subsequent processing</b> <b>its showing as ODS activation</b><b>?(change-log):not yet activated</b> and overall the error is <b>Missing Messages</b>.
    and its also saying like "Activation of data records from ODS object ODS_SALES terminated.
    and in help node its saying like data arrived in BW and try to change the request from red to green?
    can anyone tell me what will be the problem?
    In settings of ODS object everthing is set to automatically.
    many thanks
    balaji

    Hi praveen
    problem is <b>generic</b> here.
    In monitor tab the <b>request</b> and <b>overall</b> the statuts is "<b>RED</b>",but when I went into the <b>mange</b> tab of ODS object here the request is "<b>GREEN</b>",but the data is not available here.but data is still available in "<b>New data</b>",how come data is not yet activated.
    bcoz in settings all are set to "automatically",so there is no question of manual activation?
    One more question is in Settings Iam finding one column like "<b>Unique Data Records</b>",whats's this,if v check this what happens ifnot what happens?
    regrads
    balaji

  • Test Package in Test Management tab of Change Document

    Hi Expert,
    When we test on CHARM, we realized that the test package in test management tab can only be
    attach before the developer change the status to "Pass normal change to
    test". Is this standard or can we do any configuration to allow the
    test package be attach during "Test for Preliminary Input" status?
    Thanks
    Best Regards
    Remy

    Hi,
    I manage to solve this issue as below,
    Go to SPRO
    >SAP Solution Manager Implementation Guide
    >SAP Solution Manager
    >Capabilities (Optional)
    >Change Control Management
    >Standard Configuration
    >Change Request Management Framework
    >Adjust UI objects by User Status
    Thanks
    Best Regards
    Remy

  • Cargo management tab is missing in Ocean freight booking

    Hi Experts,
    I found cargo management tab is missing in Ocean freight booking/ Transportation cockpit, though hierarchy types assigned for the functionality to create drayage orders.
    Please suggest if any configuration is missing.
    Thanks,
    Shakti

    Hi Matt,
    you can find associations DRAYAGE_TOR (from booking to freight order(s)) and DRAYTOR_BOOK (from freight order to booking) under the ROOT node of business object /SCMTMS/TOR. If you check those in TA /BOBF/CONF_UI, you can also have a look at the corresponding implementing classes - however, there should be no need to do this
    Technically, the references are stored on ITEM_TR level, but as determining the correct references can be tricky, I would strongly recommend to use the above mentioned associations in order to get the pre-carriage order (or booking vice versa), instead of trying to determine them on your own from various DB tables - we already implemented the tricky part in the associations, so there is no need for you to worry about that
    Best regards,
    Sabine

  • Where we can use standard ODS Object and Trasactional ODS Object ?

    Where we can use standard ODS Object and Trasactional ODS Object ?

    Hi,
    In a standard ODS object, data is stored in different versions (active, delta, modified), whereas a transactional ODS object contains the data in a single version.  Therefore, data is stored in precisely the same form in which it was written to the transactional ODS object by the application. In BW, you can use a transaction ODS object as a data target for an analysis process. The transactional ODS object is also required by diverse applications, such as SAP Strategic Enterprise Management (SEM) for example, as well as other external applications.Transactional ODS objects allow data to be available quickly. The data from this kind of ODS object is accessed transactionally, that is, data is written to the ODS object (possibly by several users at the same time) and reread as soon as possible.
    It offers no replacement for the standard ODS object. Instead, an additional function displays those that can be used for special applications.
    Regards,
    R.Ravi

  • Customized tabstip for CV01N in Object link tab like customer ,material

    Hi Friends,
    Can anybody help me out in Customizing Object Links tab for Transaction CV01N.
    I want to know exactly how could we add a customized tabstip in object link other than SAP Standards like  Material Master, WBS element and etc.
    I want to know whether do we have any SAP Note or any Badi  to get the tab strip in Object Link tab.
    Thanks in advance.
    Satish Raju

    Hey,
    Material master is standard object to link to
    Go to IMG ->Cross-Application Components->Document Management->Control Data->Define Document Types
    choose the document type and double click at  Define object links and "New Entries"
    and enter
    Document Type: Your document type
    Object: MARA
    Screen no.: 201
    When New Version: Decide what you want
    Create Document: Decide what you want
    Document Version:Decide what you want
    BR/Håkan

  • SC DPM 2012 r2 Console Crashes when attempting to Open the Management Tab after Update to RU2

    Recently we Updated our DPM server to DPM 2012 r2 ru2 from ru1.  and after that every time we open the management tab in the console it crashes with the following error
    mmc has stopped working
     Application Name: mmc
      Application Version: 4.2.1205.0
      Module Name: mmc.exe
      Module Version: 6.3.9600.16384
      Exception Name: System.NullReferenceException
      Exception Point: Microsoft.Internal.EnterpriseStorage.Dls.UI.ObjectModel.AgentManagement.ProductionServerController.UpdateProtectionStatus
      Other: AC213896
      OS Version: 6.3.9600.2.0.0.400.8
      Locale ID: 1033
    at the same time the following event is logged in the application events
    event ID 999
    An unexpected error caused a failure for process 'mmc'.  Restart the DPM process 'mmc'.
    Problem Details:
    <FatalServiceError>
    <__System>
    <ID>19</ID>
    <Seq>0</Seq>
    <TimeCreated>6/23/2014 4:25:37 PM</TimeCreated>
    <Source>DpmThreadPool.cs</Source>
    <Line>163</Line>
    <HasError>True</HasError>
    </__System>
    <ExceptionType>NullReferenceException</ExceptionType>
    <ExceptionMessage>Object reference not set to an instance of an object.</ExceptionMessage>
    <ExceptionDetails>
    System.NullReferenceException: Object reference not set to an instance of an object.
      at Microsoft.Internal.EnterpriseStorage.Dls.UI.ObjectModel.AgentManagement.ProductionServerController.UpdateProtectionStatus()
      at Microsoft.Internal.EnterpriseStorage.Dls.UI.ObjectModel.AgentManagement.ProductionServerController.OnUpdateProtectionStatus(Object unUsed)
      at System.Threading.ExecutionContext.RunInternal(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx)
      at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx)
      at System.Threading.QueueUserWorkItemCallback.System.Threading.IThreadPoolWorkItem.ExecuteWorkItem()
      at System.Threading.ThreadPoolWorkQueue.Dispatch()
    </ExceptionDetails>
    </FatalServiceError>
    We have updated the dpm agents on all of the servers that we back up by installing the update on the servers manually and according to the data in the DPM database it has acknowledged that they are indeed updated.
    From what I can tell from the errors is the console is attempting to read the updateprotectionstatus from the database and it is not returning a value and thus causing it to crash.  but I have no clue as to where this might be in the database to even
    check if it simply missing from an update gone wrong.  
    I did notice that the update attempted to install twice through windows update and failed.  The update does show as installed under installed updates in programs and features control panel
    Any help on this would be appreciated as it does make it difficult to manage our dpm server

    Hi,
    See if this is relevant.
    1. Take a DPMDB backup.
    2. Open SQL Management studio and connect to the DPM instance.
    3. Expand the DPM database and go to the table tbl_AM_Server.
    4. Edit the table, and under the "ServerName" column check for the DPM server name. It should be the FQDN. If it is the NetBIOS name then change it to the FQDN. 
    5. Try re-opening the DPM console and navigate to the management tab and see if that works now.
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread. Regards, Mike J. [MSFT]
    This posting is provided "AS IS" with no warranties, and confers no rights.

  • PA30- Object Manager

    In PA30 if we switch on the object manager, we get a section in the left hand side "Find by".
    Here we get only "Person" and under it "Collective search help", "Search Term" and "Free Search".
    How can we add other objects in this section like Organizational unit, Position, Job etc. as we get in the Object Manager in PPOME

    Hi,
    PA30 transaction is designed only to show employees.
    If you add org unit, position, etc to Object manager, then it is contrary to the aim of this transaction.
    If you, however, wanna see people belonging to a particular org unit or position, then you can use "Organizational Assignment" tab in the collective search help.
    Regards,
    Dilek

  • Error when transporting ODS Object

    Hi All,
    I got the following error when transporting ODS object.
    "The creation of the export DataSource failed"
    "RFC connection to source system QB1CLNT100 is damaged ==> no Metadata upload"
    "Error when creating the export DataSource and dependent Objects. Error when activating ODS Object 0FIGL_O10"
    Maybe somebody can help me.
    Thanks a lot and appreciate that,
    -Martin-

    hi Martin,
    check oss note 597326 - Activating ODS: Error when creating the export DataSource
    Symptom
    When you activate or transport ODS objects, the following errors appear in the log:
    "The creation of the export DataSource failed". Message number RSBM 035
    "Error &1 in function module &2". Message number RSBM 006
    "<b>Error when creating the export DataSource and dependent Objects</b>". Message number RSDODSO 169
    "Error when activating the ODS object &1". Message number RSDODSO 168
    Other terms
    RSBM 035, RSBM 006, RSDODSO 169, RSDODSO 168
    Reason and Prerequisites
    A characteristic involved is active but it is using new or inactive attributes.
    Characteristics involved are all characteristics used in the ODS object.
    Solution
    Check all characteristics involved as described in the following:
    Check the Compounding and Attributes tabs in the characteristics maintenance.
    All characteristics here must be active. This is displayed by a green icon.
    If this is not the case for a characteristic involved (a gray icon is displayed on one of the two tabs), activate the characteristic involved. This also activates the inactive dependent characteristics.
    After you have checked and repaired all the characteristics involved as described above, the loading/maintenance of master data should work again.

  • What is the ODS object settings?

    What is the ODS object settings?

    Use
    When creating and changing an ODS object, you can make the following settings:
    BEx Reporting
    With the BEx Reporting indicator, you determine whether the ODS object is immediately available for BEx queries. If the indicator is not set, no SIDs are generated for the new characteristics when the data in the ODS object is activated. This optimizes the performance of the activation process, but the ODS object is not available as an InfoProvider for queries. Turn the indicator off for all ODS objects that are only being used for further processing of data in other data targets or that are being used in InfoSets.
    ODS Object Type
    Select the ODS object type. You can choose between standard and transactional, whereby standard is pre-installed and transactional is only meant for special cases. You can switch the type as long as there is still no data in the ODS object.
    See also Transactional ODS Objects.
    Unique Data Records
    With the Unique Data Records indicator, you determine whether only unique data records are to be updated to the ODS object. This means that you cannot load a data record into the ODS object the key combination for which already exists in the system u2013 otherwise a termination occurs. Only use this setting when you are sure that only unique data records are to be loaded into the ODS object (for example, single documents). A typical application of this is in the loading of mass data. It improves the load performance.
    Note
    You can also deselect this indicator again (even if data has already been loaded into the ODS object). This can be necessary if you want to re-post deleted data records using a repair request (see: Tab Page: Updating). In this case, you need to deselect the Unique Data Records indicator before posting the repair request, following which you can then reset the Unique Data Records indicator once more. The regeneration of metadata of the Export DataSource, which takes place when the ODS object is reactivated, has no effect on the existing data mart delta method.
    Check Table for the InfoObject
    Here the name of the InfoObject is displayed for which the ODS object is also the check table, if necessary. You can specify this when creating an InfoObject. See also Tab Page: Master Data/Texts in the InfoObject maintenance.
    Automatically Setting Quality Status to OK
    With this indicator, you can determine that the system automatically sets the quality status to OK after loading data into the ODS object. You should turn on this function. You should only deselect this indicator if you want to check the data after it has been loaded.
    Automatically Activating the ODS Object Data
    With this indicator, you can establish that the data that has Quality Status OK be transferred from the activation queue into the active data table, and that the change log is updated. Activation is carried out by a new job that is started after loading into an ODS object is complete. If the activation process terminates, there can be no automatic update.
    Automatically Updating Data from the ODS Object
    With this indicator, you can establish that the ODS object data be automatically updated. Once it has been activated, the data is updated in the data targets. An init. update is carried out automatically with the first update. If the activation process terminates, there can be no automatic update. The update is carried out by a new job that is started once activation is complete.
    Note
    Only activate automatic activation and updating if you can ensure that these processes do not overlap.
    If you use process chains to guarantee serial processing of the process, these settings are not supported for the object (with the exception of setting the quality status). Then you have to include the automatic processes as process types in the process chain.
    Also refer to the example for Including ODS Objects in Process Chains.

  • Error:Activation of data records from ODS object terminated

    Hi All
    i got error while loading the data "Activation of data records from ODS object terminated '
    could you please tell me procedure how can i solve this issue?
    regards
    vasu.

    - First check the Error Messages from the context menu of the activation step. Also check ST22 & SM21. This will tell you where the error is. Sometimes you might get duplicate records.
    - Next use the "Manage" context menu for the ODS in RSA1. Check if any of the previous records are red. If its red, it would mean that either load/activation has failed for previous request which needs to be corrected first b4 you correct the current one.
    - If al the above are OK, simply repeat the Activation step.
    Hope this helps.
    Regards
    Anujit Ghosh

  • Error while activating ODS Object

    Hi,
    I have loaded the data from R/3 to a ODS Object and the activation of ODS failed due to the following errors as shown below..
    -Value '20060 ' of characteristic 0CALQUARTER is     not  plausible
    -Error when assigning SID (details in long text)
    -Activation of data records from ODS object ZODS_02 terminated
    -Error getting SID for ODS object ZODS_02
    I could see that Calendar Quarter as 20060 in PSA. How should i get rid of this error. Any idea would be appreciated.
    Regards,
    Raj

    Raj,
       you are getting this calender qurter from SAP right... check in RSA3 fro the your Datasource. if you are getting same value like '20060'. you can do one thing... you can set 'No Update' in Transfer Rules. you can write a routine in Update Rules for populating the data for calender Week.
    you can call some standard function modules or you can write a small routine. If you want to write a routine check this thread...Re: Date to Quarter
    Possibilites:
    1. updtae rules
    2. if RSA3(PSA) shows the value of the Quarter as '20050', if it is custom extractor(Generic using FM) you can change this.
    3. If it is Standard Extractor or Generic Extractor (using either view/table or Infoset) you can enhance this. you can do the same thing in SAP Side.
    All the best.
    Regards,
    Nagesh Ganisetti.

Maybe you are looking for

  • Customer Vendor balance upload

    Hi all, how we can upload customer vendor balance .wchich template is there in DTW for Customer vendor balance upload

  • Problem in installing iAS6.5 (under clustering) on solaris 8

    I installed iAS 6.5 on solaris 8. The system is consisted of one web server and 2 application servers. The directory server is installed in only one application server and the other application server used that. Of course, those servers are the same

  • Rollover state not working on type

    I have type that is supposed to act as a hyperlink. I've enabled it, and selected the color, etc. It looks fine in iweb, but when i publish it, there are no rollover states at all. The only thing I can think of, is that i've put a drop shadow on the

  • Trouble making a clipping mask in Photoshop

    I have the following set up: I would like to make a clipping mask out of all of the objects above the "Text" layer (so that all of the stuff from the above layers is only applied to the letters), however I am struggling. For one, when I go to ungroup

  • My MacBook Pro 15" i7 2011 freezes suddenly minutes after starting up.

    My MacBook Pro 15" i7 2011 freezes suddenly minutes after starting up the computer. Sometimes it beeps after freezing, and keeps beeping forever until I shut down the computer by pressing the power button. Other times the screen gets a little darker