In SMQ1 (qRFC Monitor) status

Hi,
In SMQ1 (qRFC Monitor) I have status 'NOSEND'. In the table TRFCQOUT, some entries have the status 'READY', others 'RECORDED'. ARFCSSTATE is 'READ'. What do these statuses mean? Which values in the field 'Status' mean what and which values are correct and which are alarming? Are the statuses BW-specific or generally valid in qRFC?
Thanks,
Pradeep

Hey pradeep,
Don't post the interview question over here.
Table TRFCQOUT and ARFCSSTATE: Status READ means that the record was read once either in a delta request or in a repetition of the delta request. However, this does not mean that the record has successfully reached the BW yet. The status READY in the TRFCQOUT and RECORDED in the ARFCSSTATE means that the record has been written into the DeltaQueue and will be loaded into the BW with the next delta request or a repetition of a delta. In any case only the statuses READ, READY and RECORDED in both tables are considered to be valid. The status EXECUTED in TRFCQOUT can occur temporarily. It is set before starting a DeltaExtraction for all records with status READ present at that time. The records with status EXECUTED are usually deleted from the queue in packages within a delta request directly after setting the status before extracting a new delta. If you see such records, it means that either a process which is confirming and deleting records which have been loaded into the BW is successfully running at the moment, or, if the records remain in the table for a longer period of time with status EXECUTED, it is likely that there are problems with deleting the records which have already been successfully been loaded into the BW. In this state, no more deltas are loaded into the BW. Every other status is an indicator for an error or an inconsistency. NOSEND in SMQ1 means nothing (see note 378903). The value 'U' in field 'NOSEND' of table TRFCQOUT is discomforting.
Hopefully this is the correct answer that u were looking for your question
Thanks,
Om Ambulker

Similar Messages

  • Qrfc Monitor

    Hi All,
    when activating the integration models i receive the message Outbound Queue blocked in a dialog box , In the dialog box i have three options 1. Qrfc monitor , 2. Ignore and 3. Cancel. when i click qrfc monitor , i can see a status SYSFAIL.
    how I can i proceed with issue now , how can i release the block in the queue,
    becoz whenever i activate any of the integration model , I receive the same error
    Outbound Queue blocked in a dialog box .
    Thanks
    Shan

    Hi Shan,
    In SMQ1 (Outbound Queue Manager) put in the appropriate Queue Destination and Execute F8. This takes you to next screen - where all the stuck queues/blocks are listed. You need to select each and either double-click on the queue name of press F7 (Display Selection) which takes you to next screen.
    This screen shows more details of the queue. You can try selecting the queue block and click on the Matchstick icon F6 (Activate Queue). If there are multiple entires in the queue block then you can doubleclick on the queue name or F7 to list the inidividual queues. Select the queue which says SYSFAIL and try fixing the root cause before you select the queue and press F6 - Execute LUW. Please note unless you have fixed the root cause of the queue you can not process it. It will continue to give you the error.
    Also when you are trying to activate the integration model and getting the error - try selecting the Ignore option and see what happens. Sometimes the stuck queue is for something else than what you are trying to transfer and system by design flags it when you do the integration model activation.
    Hope this helps. Do provide further details like the type of queue stuck, the integration model you are trying to activate if you continue having the problem. Screenshots are preferable - but then not sure how you can put them here.
    Thanks,
    Somnath

  • QRFC Monitor in R/3

    Hey friends
    What is the transaction to go to the qRFC Monitor ( Outbound Queue ) in SAP R/3 system ?
    thanks

    Hi,
    SMQ1  is the Tcode.
    With rgds,
    Anil Kumar Sharma .P

  • Diff between RSA7 and qRFC MOnitor

    Hi all,
    What is the relationship between RSA7 and the qRFC monitor (Transaction SMQ1)?
    regards,
    jimmy

    Hi jimmy,
    The qRFC monitor basically displays the same data as RSA7. The internal queue name must be used for selection on the initial screen of the qRFC monitor. This is made up of the prefix 'BW, the client and the short name of the DataSource. For DataSources whose name are 19 characters long or shorter, the short name corresponds to the name of the DataSource. For DataSources whose name is longer than 19 characters (for delta-capable DataSources only possible as of PlugIn 2001.1) the short name is assigned in table ROOSSHORTN.
    In the qRFC monitor you cannot distinguish between repeatable and new LUWs. Moreover, the data of a LUW is displayed in an unstructured manner there.
    Regards,
    Anish

  • Approval process monitor status turn to "Initiated" instead of "Pending", so awe is not routed

    When I submit a transaction, after successful submission in approval process monitor the status has turn "Initiated" instead of "Pending". That's why it's showing "Not Routed" for the next approving person. So that worklist is not populated.
    Please suggest me to resolve this issue.
    Process Monitor as follows after submission:
    Separation Approval Process (Stage)
    Initiated (Monitor status)
    Approval Routing from Unit HR (Path)
    Not Routed    (Step)                                                    Not Routed      (Step)
    Multiple Approvers                                                     Multiple Approvers
    STATEHR ROLEUSER SEPARATION                              Central Hr
    (Userlist)                                                                        (Userlist)

    Looking at the error message "The Network Adapter could not establish the connection" , It appears hostname and port may be incorrect. Review the targets.xml under E:\oracle\product\10.2.0\db_1\SAP_solman_SDB\emd and
    emoms.properties under E:\oracle\product\10.2.0\db_1\SAP_solman_SDB\config folder to make sure host ( sap_solman) and port (1527) are correct.
    As far as setting the environment variables goes, you can go to control panel -> system -> advanced -> environment variables and set the ORACLE_HOME and ORACLE_SID
    -Ramesh

  • I have a L7680 All in with two new print heads but the new cyan/magenta shows yellow monitor status.

    I have a L7680 All in with two new print heads but the new cyan/magenta shows yellow monitor status. Ink status, cyan more than 50% and magenta is a 25% w/no low ink warnings... Just ran a clean print head again, print out looks good now but the status of the new cyan/magenta shows yellow monitor status. Is it time to buy another..When I purchased this printer it had to be replaced 3 times because of problems... Just a lemon?
    thx for your help in advance...
    Jim

    Could you share a link to the page?
    Seeing it in context and in our browsers is much easier to debug.
    If not, make sure to run the validator here The W3C Markup Validation Service and clear out any problems. HTML errors, especially structural ones, will cause all kinds of display problems in various browsers/versions/platforms.

  • QRFC Monitor(Inbound Queue)

    Hi Group,
    Can any one please explain the purpose of qRFC Monitor, i mean from this what inforamtion we can monitor, and when this queue is filled..............
    Thanks in Advance,
    Regards
    Ramakrishna Kamurthy

    If youhave a look at this, it might be helpful
    http://help.sap.com/saphelp_nw04/helpdata/en/0b/80f83b0255a206e10000000a11402f/frameset.htm
    Assign points if useful

  • Monitor status is yellow  for many days

    Hi All,
    I am extracting data from CRM and when I try to extract data for both master data objects and cubes, the monitor status is in yellow for many hours and not getting changed.
    Result: data is not come to BW.
    Observation:
    1) In source system the job is not getting started for ALEREMOTE_CR user and always in ready mode.
    2) In monitor screen in BW when I click on OLTP push button, system not allowing me to enter in to Source system and saying check the connection parameters. (Source system connection  check is OK)
    Kindly look in to this and feel free to contact me for any explanation is required.
    Regards,
    venkat.mahipathi
    [email protected]
    09886652422
    Edited by: siva reddy on Jan 28, 2008 8:24 AM

    Hi,
    I will suggest you to check a few places where you can see the status
    1) SM37 job log (In source system if load is from R/3 or in BW if its a datamart load) (give request name) and it should give you the details about the request. If its active make sure that the job log is getting updated at frequent intervals.
    2) SM66 get the job details (server name PID etc from SM37) and see in SM66 if the job is running or not. (In source system if load is from R/3 or in BW if its a datamart load). See if its accessing/updating some tables or is not doing anything at all.
    3) RSMO see what is available in details tab. It may be in update rules.
    4) ST22 check if any short dump has occured.(In source system if load is from R/3 or in BW if its a datamart load).
    5) SM58 and BD87 for pending tRFCs
    Once you identify you can rectify the error.
    If all the records are in PSA you can pull it from the PSA to target. Else you may have to pull it again from source infoprovider.
    If its running and if you are able to see it active in SM66 you can wait for some time to let it finish. You can also try SM50 / SM51 to see what is happening in the system level like reading/inserting tables etc.
    If you feel its active and running you can verify by checking if the number of records has increased in the new data table.
    Thanks,
    JituK

  • New Here: Application to monitor status of Weblogic queues and bridges

    hi
    I'm new to weblogic and I have to build a small tool/application to monitor status of Weblogic queues and bridges.
    I want to know if there is any API that I can use or any script in Java or any other language?
    Thank you

    for that kind of stuff maybe the easiest choice is using WLST
    there are a number of scripts published on the excellent middlewaremagic.com site
    if you google
    site:middlewaremagic.com monitoring jms
    you will find plenty of stuff

  • Monitoring Status is Still Gray [Not Performed] When Technical Monitoring Setup DOne

    Dear SAP Expert,
    I have problem when setup technical monitoring SAP system through t-code SOLMAN_SETUP in Solman.
    Managed system configuration (satellite system) was configured with green indicator for all steps.
    Technical monitoring (system monitoring) steps were configured also with green indicator for all steps.
    After configure technical monitoring, i found the status of monitoring status for that satellite system still gray (not performed).
    And after 2 day the status is not changed yet to another indicator.
    There is no problem with network firewall and server firewall.
    Is there anyone of you have experience to solve this problem?
    Please help me to solve this problem.
    Thanks & regards,
    Husin.

    Hi Husin,
    If the status is still grey please re-execute the steps mentioned in SAP note 1819848 - All metrics are grey in Technical Monitoring to see if this helps.
    Kind regards,
    Roland

  • Windows Screen Saver and Monitor Status

    How do I communicate to windows to find the Windows screen saver status and the monitor status?
    Tim
    Johnson Controls
    Holland Michigan

    I don't know the particular API calls you need for that, but here's the general way to access Windows innards:
    Use the CALL LIBRARY function, and point it to ADVAPI32.dll.
    This particular call is set up to call "GetUserNameA", returning the logged-in user's name.
    If there's an API for what you need, then configure this function to go call it.
    Steve Bird
    Culverson Software - Elegant software that is a pleasure to use.
    Culverson.com
    Blog for (mostly LabVIEW) programmers: Tips And Tricks

  • Technical monitoring status shows grey

    Hello,
    Checking the technical monitoring status, it shows grey
    Checked the error & it shows the extractor not executed.
    When checking the extractor status, its executed for host & not for the ABAP instance. Please assist.
    Other systems have the extractor info as below
    Thanks,

    Hi Magesh,
    Pls refer below notes & links
    1853160-Grey Host Metrics in Technical monitoring
    System Monitoring grey status
    SOLMAN 7.1 Technical Monitoring - System Monitoring - Host Grey
    Regards
    K.N

  • QRFC monitor activate scheduler

    Hi
    Can anyone explain me the use of qRFC monitor in R/3 system,what is the use of activate scheduler in qRFC monitor?
    and if  i do that what effect it will have on tRFC queue ?
    Sonal...

    Hello Sonal,
    The Qout sheduler is fot outbound queue. The activation is required for
    any blocked queues. Please refer to following help urls to gain further insight.
    http://help.sap.com/saphelp_nw04/helpdata/en/15/0eff40e39ba854e10000000a1550b0/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/4c/cf5c3c3b067331e10000000a114084/content.htm
    Hope this helps.
    Regards,
    Asit Ramteke

  • MTE Class for qRFC monitoring

    Hi experts,
    I need to configure a new queue group to monitor some of the outbound qRFC BW queues. Which MTE class should i opt for in RZ21? And which Exit FM should i select?
    Thanks.
    Rgds,
    Diana

    Please check whether saposcol is running, also check the status of the agent in Rz21.
    Test the agent and connection.
    Regards,
    Jagan

  • Message monitoring Status Waiting for email receiver

    Hi Guru,
    Scenario:  SAP ECC will call Error Handling interface class. The communication channel for the Error Handling interface is Email Adapter.
    Below is CC setting:
    Adapter Type: Mail  (Receiver)
    Transport Protocol: SMTP
    Message Protocol: XIALL
    Adapter Engine: Integration Server
    URL: smtp://11.11.11.111/
    Check - Configure User Authentication
    User : user1
    Password: password
    Mail Attributes:
      From: [email protected]
      To    : [email protected]
      Subject : test
      Content Encoding: base64
    I encountered one problem where my email receiver status in message monitoring is always 'Waiting'. I do not know what went wrong in the setting? Does anyone know how to solve my problem ?
    Thanks in advance.
    Regards

    XI tries 3 times before changing the status of the message to System Error. One can Manually resend the error messages by using the RESEND button in RWB. In scenarios where XI was trying to send the message to an end system that was down for maintenance, you would want XI to resubmit the message automatically without human intervention. What would be nice is to able to tune the retries like IS_Retry which is available for Integration engine.
    We can achieve this by changing the retry count used by the Adapter Engine, by default its set to 3 times, 5 minutes apart. This count can be changed in Visual Admin->server->services-> SAP XI Adapter: XI.
    Here  change the number Retries parameter from 3 to 10 and change the retry retryInterval to around 10minutes. For these configuration changes to be picked up, restart SAP XI Adapter: XI.
    please visit the blog
    /people/sap.user72/blog/2005/11/29/xi-how-to-re-process-failed-xi-messages-automatically