In TEST STAND

How do I insert the company logo in the test report?

Hi,
This example should help
http://sine.ni.com/apps/we/niepd_web_display.display_epd4?p_guid=B45EACE3E28156A4E034080020E74861&p_node=DZ52224&p_source=external
Also the Getting Started Manual Chapter 12 (for TestStand 2.0.1) has an example added a logo in the report.
Regards
Ray Farmer
Regards
Ray Farmer

Similar Messages

  • Is there a way to create a database with Test Stand?

    Anyone know of a way to have Test Stand create a database? My company standard MS Office suite is Microsoft Access 2010, and TestStand does not support the .accmdb extension type(format), so I have to create new databases using old formats. I'm worried about backwards compatability down the road since good ole Microsoft doesn't seem to care about legacy formats.
    I'm still a beginner with databasing, so any suggestions would be greatly appreciated.

    TestStand 2012 SP1, and  we are using a modified Generic Recordset (NI). The problem we are having right now is that the Build SQL instructions are not creating the database tables the way we are configuring them from the "Statements" and "Column/Parameters" tabs under Database Options.
    What is happening is when we validate the schema, and drop all schema tables, it empties all the database tables, but then when you build using the TestStand generated sql file, we get errors(shown below) we are not understanding, and we can no longer write to the database and LabVIEW throws a "Data type mismatch in criteria expression" error like this
    "Possible reason(s):
    ADO Error: 0x80040E07
    Exception occured in Microsoft JET Database Engine: Data type mismatch in criteria expression. in NI_Database_API.lvlib:Conn Execute.vi->TSData - Query Actions.vi->Retrieve Test Data.vi->ARA-63 Data Miner.vi->ARA-63 Data Miner.vi.ProxyCaller"
    ==================================================================================================== > CREATE TABLE UUT_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STATION_ID VarChar(255), BATCH_SERIAL_NUMBER VarChar(255), TEST_SOCKET_INDEX Long, UUT_SERIAL_NUMBER VarChar(255), USER_LOGIN_NAME VarChar(255), START_DATE_TIME DateTime, EXECUTION_TIME Double, UUT_STATUS VarChar(32), UUT_ERROR_CODE Long, UUT_ERROR_MESSAGE VarChar(255), PART_NUMBER VarChar(255), TSR_FILE_NAME VarChar(255), TSR_FILE_ID VarChar(64), TSR_FILE_CLOSED Bit, PART_NAME VarChar(255), PRG VarChar(255), Comment VarChar(255), Operator VarChar(255)) Command issued.
    > CREATE TABLE STEP_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, UUT_RESULT Long, STEP_PARENT Long, ORDER_NUMBER Long, STEP_NAME VarChar(255), STEP_TYPE VarChar(255), STEP_GROUP VarChar(32), STEP_INDEX Long, STEP_ID VarChar(32), STATUS VarChar(255), REPORT_TEXT VarChar(255), ERROR_CODE Long, ERROR_MESSAGE VarChar(255), CAUSED_SEQFAIL Bit, MODULE_TIME Double, TOTAL_TIME Double, NUM_LOOPS Long, NUM_PASSED Long, NUM_FAILED Long, ENDING_LOOP_INDEX Long, LOOP_INDEX Long, INTERACTIVE_EXENUM Long, CONSTRAINT STEP_RESULT_FK FOREIGN KEY (UUT_RESULT) REFERENCES UUT_RESULT (ID)) Command issued.
    > CREATE TABLE STEP_SEQCALL ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STEP_RESULT Long, SEQUENCE_NAME VarChar(255), SEQUENCE_FILE_PATH LongText, CONSTRAINT STEP_SEQCALL_FK FOREIGN KEY (STEP_RESULT) REFERENCES STEP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STEP_RESULT Long, PROP_PARENT Long, ORDER_NUMBER Long, NAME VarChar(255), PATH LongText, CATEGORY Long, TYPE_VALUE Long, TYPE_NAME VarChar(255), DISPLAY_FORMAT VarChar(32), DATA Double, FORMATTED_DATA VarChar(255), CONSTRAINT STEP_NUMERICLIMIT1_FK FOREIGN KEY (STEP_RESULT) REFERENCES STEP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_NUMERICLIMIT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, COMP_OPERATOR VarChar(32), HIGH_LIMIT Double, LOW_LIMIT Double, UNITS VarChar(255), STATUS VarChar(255), HIGH_LIMIT_FORMATTED VarChar(255), LOW_LIMIT_FORMATTED VarChar(255), CONSTRAINT STEP_NUMERICLIMIT2_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STEP_RESULT Long, PROP_PARENT Long, ORDER_NUMBER Long, NAME VarChar(255), PATH VarChar(255), CATEGORY Long, TYPE_VALUE Long, TYPE_NAME VarChar(255), DISPLAY_FORMAT VarChar(32), DATA VarChar(255), FORMATTED_DATA VarChar(255), CONSTRAINT PROP_MULTINUMERICLIMIT1_FK FOREIGN KEY (STEP_RESULT) REFERENCES STEP_RESULT (ID), CONSTRAINT PROP_MULTINUMERICLIMIT1_FK FOREIGN KEY (PROP_PARENT) REFERENCES PROP_RESULT (ID)) Command failed with the following error...: Table 'PROP_RESULT' already exists. (-2147217900)
    > CREATE TABLE PROP_NUMERICLIMIT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, COMP_OPERATOR VarChar(32), HIGH_LIMIT Double, LOW_LIMIT Double, UNITS VarChar(255), STATUS VarChar(255), HIGH_LIMIT_FORMATTED VarChar(255), LOW_LIMIT_FORMATTED VarChar(255), CONSTRAINT PROP_MULTINUMERICLIMIT2_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command failed with the following error...: Table 'PROP_NUMERICLIMIT' already exists. (-2147217900)
    > CREATE TABLE PROP_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STEP_RESULT Long, PROP_PARENT Long, ORDER_NUMBER Long, NAME VarChar(255), PATH VarChar(255), CATEGORY Long, TYPE_VALUE Long, TYPE_NAME VarChar(255), DISPLAY_FORMAT VarChar(32), DATA VarChar(255), FORMATTED_DATA VarChar(255), CONSTRAINT PROP_RESULT_FK FOREIGN KEY (STEP_RESULT) REFERENCES STEP_RESULT (ID)) Command failed with the following error...: Table 'PROP_RESULT' already exists. (-2147217900)
    > CREATE TABLE PROP_ANALOGWAVEFORM ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, INITIAL_T DateTime, DELTA_T Double, INITIAL_X Double, DELTA_X Double, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), DATA_FORMAT VarChar(32), DATA LongBinary, ATTRIBUTES LongText, CONSTRAINT PROP_ANALOGWAVEFORM_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_DIGITALWAVEFORM ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, INITIAL_T DateTime, DELTA_T Double, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), TRANSITIONS LongBinary, DATA LongBinary, ATTRIBUTES LongText, CONSTRAINT PROP_DIGITALWAVEFORM_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_ANALOGWAVEFORM ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, INITIAL_X Double, DELTA_X Double, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), DATA_FORMAT VarChar(32), DATA LongBinary, ATTRIBUTES LongText, CONSTRAINT PROP_IVIWAVE_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command failed with the following error...: Table 'PROP_ANALOGWAVEFORM' already exists. (-2147217900)
    > CREATE TABLE PROP_ANALOGWAVEFORM ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, INITIAL_X Double, DELTA_X Double, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), DATA_FORMAT VarChar(32), DATA LongBinary, ATTRIBUTES LongText, CONSTRAINT PROP_IVIWAVEPAIR_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command failed with the following error...: Table 'PROP_ANALOGWAVEFORM' already exists. (-2147217900)
    > CREATE TABLE PROP_BINARY ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), DATA_FORMAT VarChar(32), DATA LongBinary, CONSTRAINT PROP_BINARY_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command issued.

  • How to bring a VI front panel to the front (of all open windows) when the parent VI calls a sub-VI in Test Stand.

    In Test Stand when I call a sub-VI front panel, the pop-up window goes behind all the windows and the user just waits for the screen. I want the pop-up to come to the front so that the user can know what to do. I couldn't find any property that I can set which would make the called VI go to the front.

    What version of TestStand are you using? Here are the TestStand palettes in LabVIEW for TestStand 2.0 and 3.1. You can also set a VI to be modal in  VI Properties>Window Appearance. Select Dialog or go to Cutomize and change the Window Behavior.
    Message Edited by Dennis Knutson on 03-07-2006 10:32 AM
    Attachments:
    TestStand palettes.JPG ‏37 KB

  • I want to write a program in LabView then pass the test results to teststand to check if it pass or fail without displaying the test stand program,

    I want to write a program in LabView and create an execute but I want to be able to pass test results to test stand to find it the unit pass ar fail the test then save the data to a database. How would i go about it.

    What's confusing is your statement that you want to do this "without display the test stand program". You can minimize the TestStand UI to the task bar but if you don't want TestStand to be running, how can TestStand evaluate the result. Explain a little more please.
    In the message body of your post, you just say you want to create a LabVIEW exe and pass the results to TestStand. What I would recomend is that instead of an exe, you create a dll and use TestStand's DLL adapter to call it and return the results. TestStand will evaluate it and do the logging.

  • Test Stand 3.5 install problem

    I'm having problems installing Test Stand 3.5 Development Edition on a WinXP SP1 machine - would anyone have any suggestions.
    I'm performing a custom install and selecting all components other than "Device Drivers".
    The install fails on "NI TestStand 3.5 Support Files. Part 1 of 1" with "Error 1335. The cabinet file 'Cabs.m6' required for this installation is corrupt and cannot be used. This could indicate a network error, an error reading from the CD-ROM, or a problem with this package".
    If I select abort at this point the install of the support files is rolled back and the remaining components apper to install correctly. I can now run Test Stand but am missing the help files. If I rerun setup it attempts to install the support files but fails with the same error.
    I have tried uninstalling and reinstalling & have copied the CD contents to the local hard disk (without any problems) and installing from there. All this is to no avail.
    I've also uninstalled and reinstalled an installation on a second machine using the same install media. This install succedded with no issues.

    What is the difference between the two machines - where you've had successful and unsuccessful installs?
    Like you've said sometimes this is caused by a faulty read from the CD drive, or faulty media, but as you've managed the install with the same media on the machine - then its not the media, and you've already tried the copy to hard disk from the CD without any luck. 
    What OS is on this other (working) machine?
    Do you have administrator privileges on the machine where you can't install the software? Is the .NET framework 1.1 installed (I think this is part of Windows XP SP 2) so this could be the issue - as TestStand requires the .NET framework 1.1
    Also - I've attached the readme which includes information to consider before installation - and known issues with the installation - check this and see if any of these could be the issue with this machine.
    I hope this helps
    Regards
    Hannah
    NIUK & Ireland
    Attachments:
    ReadMe.txt ‏51 KB

  • Is there a max number of parameters that can be passed to a C function in test stand v. 1.0.1

    I have had an issue with test stand version 1.0.1 (yes, I know; it's quite old) and calling a C function thru an action step. when I call this function with 18 parameters, it seems to hang. I have called a function with 16 and it seems to work. Is this a limit of the software? I am calling the function from a windows DLL that we've created. When I try to pull the function from the dll into test stand I also get a { error...but I get that in the other function's call and it seems to work fine. Any ideas?

    ok, upon re-reading what I posted I can clearly see your confusion. haha. I think there are two separate issues.
    1) Are there a maximum number of parameters one can use when calling a C function from a DLL? Yes, i'm trying to call a C function from test stand.
    2) when I select the "module" tab, and select which DLL contains my function, the prototype has no information associated with it (by clicking the reload prototype button). I'm not sure why, as I'm using a declspec to send the function information out of the dll, but that's another topic. So I click on the source file tab and point the window to the .cpp of my function (within the DLL's project workspace) and when it begins to parse the file, I get an error about mis-matched curly brackets and if I wish to continue, and skip the rest of the parsing.
    I click "OK" and when I go back to the module tab, I am able to see all my functions, along with the parameters in the drop down menu below. I fill in all the parameters and everything looks ok; no syntax errors, or anything else seemingly suspicious. I then run my test stand code and when I get to the step which calls this function, the system hangs and cannot proceed.
    Any thoughts as to what might cause these issues? 

  • How to get the value of the global variable of test stand in labview User interface?

    Hi.
     Can anyone Please share examples and tell me to how access the test stand global variable using labview user interface.
    Solved!
    Go to Solution.

    I'm not surprised that what you are doing doesn't work.  The Start Execution UI Message is triggered when the user clicks a button to start an execution.  Realize that most executions go through a process model.  So you could be looking at the sequence context of the process model and not your client sequence file.
    I recommend reading that link I posted above.  UI Messages are your best bet but you cannot just piggy back on an existing UI Message like this.  They may not be getting sent at the time you need them to be.  The only way to ensure you get what you want is to trigger one yourself at the right time.
    Regards,
    jigg
    CTA, CLA
    teststandhelp.com
    ~Will work for kudos and/or BBQ~

  • How to call test Sequences developed by using CVI Test Execuitve toolkit in Test Stand?

    There is a feature in TestSatnd which can convert CVI sequence to test Stand Sequences. But test stand is not recognising these sequences saying " not a valid CVI test sequence". Is there any version Issues, while converting these sequences to TestStand?

    Hi Scott
    In continuation of previous question..
    As per the suggestion, when I am trying opening one sequence(.SQU) file,developed in CVI Test Executive V 1.0.1., in CVI Test Execcuitve V 2.0.1, Executive is throwing error.
    The Pop Error is " Section [Sequence] missing from sequence file c:\xxx.squ"..
    and when I am trying opening these sequence file in sequence editor, the tool it self is crashing.
    Please suggest!!
    Is there any specific tokens which we need to add in .SQU files of V 1.0.1, so that V 2.0.1 can understand them? Just to check the possibility of manual updation of .SQU files.
    Regards
    Amit

  • Vi session strategy with LV 7 in Test Stand

    Hi all, Im a producing a set of vi's(LV7.1) which will be strung together in a Open Visa, Write visa ..., Read visa , Close visa, over several instruments.
    I wish later to use Test Stand(3.1) to slice these routines, but I am not sure how test stand handles the session references when I break the flow.
    Im thinking of a first step that initialises all instruments , then later steps that grab the session references and perform tests.
    Do I need to store the sessions as varables in Test Stand?, or is there a better way?.Is there any examples that cover this topic?
    thanks

    I guess that a better way is NI Session Manager.
    NI Session Manager is the software component (of NI TestStand) from which you obtain instrument sessions. Session Manager returns a reference to the session object with the name you specify. If the session object you specify does not yet exist, Session Manager creates it and returns a reference to the new session.
    Session Manager also allows you to close all opened sessions automatically.
    "Only a life lived in the service to others is worth living..." - Albert Einstein
    Attachments:
    SMgrRef.chm ‏121 KB

  • Is there any way I can convert a Test stand sequence and corresponding vi's to an executable?

    I need some creative ideas on how I can convert a test stand sequence into an executable in the shortest possible time. I know that beats the entire purpose of using TestStand but I need to have a way to do this. Is there no other way i can accomplish this without writing a sequencer in LabVIEW and rewriting all of my code in LabVIEW??

    There is no way i know or can think of to move all components from a TestStand application into a single EXE. Running TS in an application means that you should/must work highly unitized during developement and deployment.
    In general:
    -> Custom UI will become "The EXE" for the enduser. This involves the link for startup on desktop/start menu.
    -> TS Engine, ActiveX Server, will be attached to the UI.EXE OS process when launched by the UI. Will never be part of the UI.EXE.
    -> TS Compontens (e.g. process model, language files, ..). Will never be part of the UI.EXE.
    -> Custom Components (e.g. modified process model components, reporting, ...). Very unlikely(never) to become part of the UI.EXE.
    -> Custom Sequences. Will never be part of the UI.EXE, but extension can be changed to other than .seq.
    -> Code modules called by custom sequences. Unlikely (but possible) to be part of the UI.EXE. Should be implemented and tested to run within the RTE (runtime engine) of the appropriate programming language. It is not par design, that the deployment system has the development environment of that programming language installed.
    -> License information. TS requires at least the Base Deployment License installed and activated (requires NI License Manager software). RTE of modules might also include licensing and possibly activation fees.
    Why is there the requirement to have a single, monolythic EXE (hard to handle!) at all? If it is about the deployment process, you know that you can provide a single MSI (Microsoft Installer) with all required components using the TestStand Deployment Utility?
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • How can I get Test Stand to print failues only?

    Rather than getting a large report file with hundreds of passes and only one failure, how do I configure Test Stand to only print the failures to the report?

    Hi,
    the engine callbacks are simply a sequence that gets called when a particular thing happens (i.e. Post Step).
    There's three types
    SequenceFile (for steps that execute in that sequence file whether it's a client sequence file or a process model)
    ProcessModel (for steps that execute in the client sequence file run under this process model, but NOT the steps in the ProcessModel)
    Station (for all steps on that installation - found in the StationCallbacks.seq sequencefile)
    If the engine callback appears in more than one of the three places, then the lowest one (seq file->proc model->station listed lowest to highest)is used.
    In your case, you could use any of them depending on your architecture.
    Personally, r
    emoving from the resultlist is easier than working out whether to add to it, but that gets tricky when you have steps which loop.
    If you decide to make up your own add, then the PostStepFailure is the callback sequence to use (go to edit->sequencefilecallbacks). You'll have to add a new element to the resultlist, and start fleshing it out with the result container of the step (which you still have access to as a parameter) plus the TS container.
    This would go into the Runstate.Caller.Locals.ResultList[x]
    Also, don't forget to disable the result collection on all the steps in the test sequence, plus all the ones in your poststepfailure callback, since you're doing your own.
    I'm attaching what I've done so far as an example - not quite finished, but it's done the TS container. Just now need to do the actual result container.
    I'll keep working on it but for now you can see what I'm getting at.
    Hope that gives you a kick start with the callbacks bit
    Sacha Emery
    National Instrumen
    ts (UK)
    // it takes almost no time to rate an answer
    Attachments:
    collect_only_failures.seq ‏31 KB

  • Can I open the (.squ) sequence files using NI test stand 4.0 version?

    I have the sequence files created using ATETool Kit test Executive. But I have NI 4.0 test stand. I want to open the sequence files using NI 4.0 test stand. Can i do that?

    Hi,
    I am not familiar with ATETool kit Test Executive, but I doubt NI TestStand will open this. As you have both, have you tried it?
    TestStand does have a conversion tool for converting NI TestExecutive sequence files into TestStand sequence files.
    Maybe you could write a conversion tool to make the conversion for you if you have many ATETool kit Test Executive files.
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • How can I pass a variable from Test Stand to CVI by reference

    Hi!
    I can't to pass numeric or boolean variable from Test Stand (for example: FileGlobals.StopFlag) into the step (CVI function).
    Function prototype: 
    void __declspec(dllexport) __cdecl PC2_WaitWhileResponceAppear(tTestData *testData, tTestError *testError, int *iStopFlag).
    When variable has bin changed I can't see this change from my function.
    CVI 2010, Test Stand 2010
    Can anybody help me?

    Hey Rombar,
    It is certainly possible to pass variables by reference; for example, if you go to <TestStand Directory>/Examples/Demo/C and open the computer.seq file, you can see one of the example sequences that uses CVI modules. If you click on one of these steps, you'll see that some of the parameters, such as the error information, is passed with pointers. This is a pass by reference.
    To help narrow this down, it'd be good for us to figure out a few things about how the code is run. First, if you go to Configure > Adapters, select the CVI adapter and choose Configure, you can see options for this adapter. Do you have it configured to run in an external instance of CVI or as an in-process call?
    Also, if you're wanting to see a change made in TestStand in your external code, this makes me think that you're wanting to run the code and then continue to execute your TestStand sequence while the code runs. How did you configure this behavior? For example, are you calling this code as a separate sequence in a new thread, or are you using another method to run this code while the sequence continues to run?
    Finally, if we could see a screenshot of how you're configuring the parameters on the TestStand step, that might be helpful as well.
    Daniel E.
    TestStand Product Support Engineer
    National Instruments

  • Clearing Test Stand engine's internal cache

    I am trying to clear the TEST STAND ENGINE'S internal cache of past sequence files in a custom Operator Interface I am developing using VB.NET.  The scenario is as follows.   The Test Stand OI application is instantiated from a desktop shortcut that also has the sequence file as a parameter.  I am using only the "Single Pass" entry point.
    The problem is other sequence files appeared to be executing in addition to the sequence file passed in as a command line argument.  I checked this by creating an event handler for the openseqfile event and putting a VB.NET debugger breakpoint at its start.  In the case I checked the seq open event fired 3 times.  Once for each of the last 3 different sequence files I tried to run.   I checked each of the files as they were being opened and the 1st file opened was the one I passed in.  The second file opened was the one I ran prior to the current application instantiation.  I checked that file an the "e.file.IsExecuting" property was TRUE!  How could that file be executing when the application starts when it is not even the file I want to run?
    The third file was a file I ran 2 instances ago and its "IsExecuting" property was false and its "CanUnload" property was true.  I was able to remove that particular file with "Me.AxApplicationmgr.GetEngine().ReleaseSeqenceFileEx(e.file)" in the event handler.
    What is the proper way to remove (clear) the interneal cache.  So only the single file I want is opened?  Thanks

    You should call ApplicationMgr.OpenSequenceFile instead of Engine.GetSequenceFileEx (see TestStand Reference Manual>> Chapter 9 Creating and Customizing Operator Interfaces >> Using the TestStand API With TestStand UI Controls).
    If you want to close the file explicitly, call ApplicationMgr.CloseSequenceFile.  If you don't close the file, the ApplicationMgr will close the file automatically when your application shuts down.
    When you call ApplicationMgr.OpenSequenceFile, the file appears in controls that display the list of open files and your application receives an ApplicationMgr.DisplaySequenceFile event for the file.
    If you can't use the ApplicationMgr methods, then I think the place to call Engine.ReleaseSequenceFileEx would be in the ApplicationMgr.QueryShutdown event (also see TestStand Reference Manual>> Chapter 9 Creating and Customizing Operator Interfaces >> Using the TestStand API With TestStand UI Controls).

  • Test Stand: How does parameter's value is passed as command line argument?

    Hi All,
    This is my 1st Q on this board.
    I'm using Test Stand Sequence to call a subsequence where I call an executable file and passing few arguments to it.
    SuperSequence.seq => SubSequence.seq
    In SuperSequence.seq I have 3 parameters and their values are specified
    Parameters
    Name      Type    Value
    ==============================
    Name      string    "Nirvana"
    Address  string    "London"
    Tel           Number "123456"
    In SubSeq.seq I call and EXE with following parameters
    Executable Path Name: myApp.exe
    Argument Expressxion:  "Parameters.Name  Parameters.Address  Parameters.Tel"
    In the application I receive parameter names instead of their values?
    E.g. I recevie Parameters.Name  Parameters.Address  Parameters.Tel in myApp.exe as arguments.
    How do I make the values to be passed to myApp.exe instaed of parameter names?
    Cheers
    Nirvana

    Hi,
    You have to make a string containing the arguments that you require
    Try the following expression
    Parameters.Name  + " " + Parameters.Address + " " +Str( Parameters.Tel)
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • Search feature in Test Stand templates

    Hi,
    I am trying to create templates of sequence steps for a particular dll in Test Stand. The dll has about 50 functions, and when I line up all of them under templates, it becomes very lenghty, and difficult to use.
    Is there a way to add  "Search/Find" feature and "Flatten / Sort" feature - similar to the one we have for LabWindows CVI function panels? If so how, and which TestStand API do I need to modify? Can we "import" this feature from CVI and reuse it some how? Any other way of doing it?
    thanks and regards
    dasi

    Hi,
    Have you had a look at ''lookup strings"? Its a TestStand API call you can make on a property object. I am not sure if it can be used for external dlls but its does the same job you are asking for.
    By default there is no function present by default. You can access the dll in labview or CVI and search for it thr and call the VI/C code as a code module in TestStand.
    hope this helps..
    Vaibhav
    .......^___________________^
    ....../ '---_BOT ____________ ]
    ...../_==O;;;;;;;;_______.:/

Maybe you are looking for

  • GUI status for report

    Hi,     I had created GUI status for output list in one report. its status is active in program but in report output this created status is not activated (Menu bar, application toolbar). Has anybody face this kind of problem before? Regards, Dilip

  • Why customer master idoc named like DEBMAS?

    hi, i am just curious know why customer master idoc named like DEBMAS? vendor master data idoc as cremas? any German abbreviation or English abbreviation behind this will be appreciated. thanks & regards Raja Message was edited by:         Raja

  • Houston based company looking for LabVIEW programmer​s

    Infodat in Houston currently has 2 openings for immediate hiring for the following: Engineers to develop software applications for integration with various hardware and control systems primarily using LabVIEW. The position involves integration of pro

  • Delete selected data in psa

    Hi guys, I want to delete some data records in psa based on a range of record number. Eg. I want to delete records in psa starting from record number 1 to 333. I would appreicate if someone can help me with that, zsl05

  • Registering ds 5.2 on dscc

    hi! im trying to register a DS 5.2 in a fresh DSCC but it complains about the DSCC agent port. DS and DSCC are running on different machines. im i missing something on the DS side? i can't find anything in the docs. regards.