Individual inventory is failing

Hello,
When running the daily inventory as usual everything is working fine.
When I try to run the inventory manually through the Action > Hardware Inventory I am getting an error in the Application Log:
Event Type: Error
Event Source: SmsAdminUI
Event Category: None
Event ID: 1
Date: 4/15/2015
Time: 3:09:38 PM
User: N/A
Computer: CONFIGMGRSRV
Description:
System.ArgumentOutOfRangeException\r\nSpecified argument was out of the range of valid values.\r\n at Microsoft.ConfigurationManagement.ManagementProvider.LoadXmlHelpers.GetManagementClassDescription(ConnectionManagerBase connectionManager, String className)
at Microsoft.ConfigurationManagement.ManagementProvider.LoadXmlHelpers.GetManagementClassDescription(String className)
at Microsoft.ConfigurationManagement.AdminConsole.ResourceExplorer.DisplayHelpers.GetHardwareItemIcon(Object sender, ScopeNode scopeNode, IResultObject resultObject, AssemblyDescription& assembly)\r\n
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
and the inventory is not done...
Any idea?
Thanks,
Dom
System Center Operations Manager 2007 / System Center Configuration Manager 2007 R2 / Forefront Client Security / Forefront Identity Manager

?bumo?
System Center Operations Manager 2007 / System Center Configuration Manager 2007 R2 / Forefront Client Security / Forefront Identity Manager

Similar Messages

  • LMS 3.2 RME 4.3.1 Inventory collection failing for switches

    I have 6 switches that inventory is failing for.  They do run the 12.2(33)SXI3 software but I have the CSCtb16925-1.0  patch installed.  I've tried to increase the SNMP timeout for the devices but they still fail.
    Ideas?
    Chris Jasztrab

    You did not properly increase the SNMP timeout.  Go to RME > Devices > Device Management > RME Devices, and edit the attributes of the device in question.  Perform an inline edit.  Click on the device name, then change the existing SNMP timeout value to 10.  Then save your changes, and apply them on the previous screen.  Then inventory collection should work.

  • LMS 4.0.1 Cisco 3925E Inventory Polling Fails

    I have an LMS 4.0.1 server (on Windows 2008 R2) with all the LMS and device updates applied that fails when trying to do an Inventory Collection on a Cisco 3925E router.  The router is running IOS Version 15.1(1)T2.  This device is apparently supported according to:
    http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/4.0/device_support/table/lms40sdt.html
    Some 'show ver' info:
    Cisco IOS Software, C3900e Software (C3900e-UNIVERSALK9-M), Version 15.1(1)T2, RELEASE SOFTWARE (fc1)
    ROM: System Bootstrap, Version 15.1(1r)T2, RELEASE SOFTWARE (fc1)
    System image file is "flash0:c3900e-universalk9-mz.SPA.151-1.T2.bin"
    Cisco CISCO3925-CHASSIS (revision 1.0) with C3900-SPE200/K9 with 689152K/293888K bytes of memory.
    'show inv':
    NAME: "CISCO3925-CHASSIS", DESCR: "CISCO3925-CHASSIS"
    PID: CISCO3925-CHASSIS , VID: V02, SN: FGL152610R8
    NAME: "Cisco Services Performance Engine 200 for Cisco 3900 ISR on Slot 0", DESCR: "Cisco Services Performance Engine 200 for Cisco 3900 ISR"
    PID: C3900-SPE200/K9   , VID: V02 , SN: FOC151828UX
    NAME: "WAN Interface Card - HWIC Serial 1T on Slot 0 SubSlot 0", DESCR: "WAN Interface Card - HWIC Serial 1T"
    PID: HWIC-1T           , VID: V04 , SN: FOC15170VRL
    NAME: "C3900 AC-POE Power Supply 1", DESCR: "C3900 AC-POE Power Supply 1"
    PID: PWR-3900-POE      , VID: V02, SN: SNI1503C7AV
    NAME: "C3900 AC Power Supply 2", DESCR: "C3900 AC Power Supply 2"
    PID: PWR-3900-AC       , VID: V03, SN: SNI1521C825
    For reference, here is the SNMP configuration on the 3925:
    snmp-server group ADMIN v3 auth
    snmp-server community <rostring> RO
    snmp-server ifindex persist
    snmp-server ip precedence 2
    snmp-server enable traps snmp authentication linkdown linkup coldstart warmstart
    snmp-server enable traps tty
    snmp-server enable traps ospf state-change
    snmp-server enable traps ospf errors
    snmp-server enable traps ospf retransmit
    snmp-server enable traps ospf lsa
    snmp-server enable traps ospf cisco-specific state-change nssa-trans-change
    snmp-server enable traps ospf cisco-specific state-change shamlink interface-old
    snmp-server enable traps ospf cisco-specific state-change shamlink neighbor
    snmp-server enable traps ospf cisco-specific errors
    snmp-server enable traps ospf cisco-specific retransmit
    snmp-server enable traps ospf cisco-specific lsa
    snmp-server enable traps flash insertion removal
    snmp-server enable traps envmon fan shutdown supply temperature status
    snmp-server enable traps bgp
    snmp-server enable traps memory bufferpeak
    snmp-server enable traps config-copy
    snmp-server enable traps config
    snmp-server enable traps entity
    snmp-server enable traps event-manager
    snmp-server enable traps cpu threshold
    snmp-server enable traps syslog
    snmp-server enable traps vtp
    snmp-server enable traps ipsla
    snmp-server enable traps bulkstat collection transfer
    snmp-server host 10.152.1.27 version 2c <rostring>
    The specific error message captured from the IC_Server.log file:
    [ Thu Sep 29  16:19:55 EST 2011 ],ERROR,[Thread-23],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1075,Exception for device 172.22.41.9 is
    java.lang.reflect.InvocationTargetException
        at sun.reflect.GeneratedMethodAccessor24.invoke(Unknown Source)
        at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
        at java.lang.reflect.Method.invoke(Method.java:597)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:1065)
        at java.lang.Thread.run(Thread.java:662)
    Caused by: com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
        at com.cisco.nm.xms.xdi.pkgs.LibInventory.EnergyWise_HelperMethods.getDeviceEnergyWise(EnergyWise_HelperMethods.java:77)
        at com.cisco.nm.xms.xdi.pkgs.SharedInventoryCatIOS.EnergyWiseAGI_ENERGYWISE_Mib.g$eval(EnergyWiseAGI_ENERGYWISE_Mib.java:51)
        at com.cisco.nm.xms.xdi.ags.EnergyWiseAGI.g$eval(EnergyWiseAGI.java:21)
        at com.cisco.nm.xms.xdi.SdiEngine.initAndEvalAGIs(SdiEngine.java:383)
        at com.cisco.nm.xms.xdi.SdiEngine.request(SdiEngine.java:309)
        at com.cisco.nm.xms.xdi.SdiEngine.getDevRepr(SdiEngine.java:302)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:687)
        ... 1 more
    [ Thu Sep 29  16:19:55 EST 2011 ],ERROR,[Thread-23],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1107, Collection failed for the device : 19
    com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
        at com.cisco.nm.xms.xdi.pkgs.LibInventory.EnergyWise_HelperMethods.getDeviceEnergyWise(EnergyWise_HelperMethods.java:77)
        at com.cisco.nm.xms.xdi.pkgs.SharedInventoryCatIOS.EnergyWiseAGI_ENERGYWISE_Mib.g$eval(EnergyWiseAGI_ENERGYWISE_Mib.java:51)
        at com.cisco.nm.xms.xdi.ags.EnergyWiseAGI.g$eval(EnergyWiseAGI.java:21)
        at com.cisco.nm.xms.xdi.SdiEngine.initAndEvalAGIs(SdiEngine.java:383)
        at com.cisco.nm.xms.xdi.SdiEngine.request(SdiEngine.java:309)
        at com.cisco.nm.xms.xdi.SdiEngine.getDevRepr(SdiEngine.java:302)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:687)
        at java.lang.Thread.run(Thread.java:662)
    I have attached a more detailed output from the IC_Server.log file for the Inventory Collection job of the device.
    The error at first glance appears to be related to EnergyWise, so I even tried creating an SNMP view that excludes the EnergyWise MIB with the following configuration:
    snmp-server view EXCLUDE-ENERYGYWISE-MIB iso included
    snmp-server view EXCLUDE-ENERYGYWISE-MIB ciscoEnergywiseMIB excluded
    snmp-server community L1ghty3@rSnmp$ view EXCLUDE-ENERYGYWISE-MIB RO
    snmp-server group ADMIN v3 auth read EXCLUDE-ENERYGYWISE-MIB
    But that didn't seem to fix it, the Inventory Collection still fails.  (Perhaps this configuration is incorrect?).
    Has anyone experienced any issues like this?  I have tried everything I can think of to fix this, and have trawled through the support forums but couldn't find anything.

    Hi,
    First of all very nice research with logs
    You are hitting the below bug , which will  be fixed in LMS 4.2.However an official Patch will be release in the mid of october so you can conatct cisco to get the Patch for the same in October.
    CSCts13593    Inventory collection fails due to VersionAPI code
    Thanks
    Afroj

  • Inventory load failed... OPatch cannot load inventory for the given Oracle Home.OPatch failed with error code = 73

    Hi,
    I am going to apply bundle patch and my oracle database is 11.2.0.2 and platform Microsoft Windows x86. As per the read me file Oracle recommends that to use OPatch utility release 11.2.0.1.3 or later.To check the accessibility to the inventory i use %ORACLE_HOME%/OPatch/opatch lsinventory command.
    It ended up with giving below details.
    Invoking OPatch 11.2.0.1.1
    OPatch could not create/open history file for writing : ***my oracle home path***\cfgtoollogs\opatch\opatch_history.txt
    **oracle_home***\cfgtoollogs\opatch\opatch_history.txt (Access is denied)
    Oracle Interim Patch Installer version 11.2.0.1.1
    Copyright (c) 2009, Oracle Corporation.  All rights reserved.
    OPatch could not open log file, logging will not be possible
    Oracle Home       : *****
    Central Inventory : C:\Program Files\Oracle\Inventory
       from           : n/a
    OPatch version    : 11.2.0.1.1
    OUI version       : 11.2.0.2.0
    OUI location      : **ORACLE_HOME***\oui
    Log file location : **ORACLE_HOME**\cfgtoollogs\opatch\opatch2015-04-09_16-27-49PM.log
    Patch history file: **ORACLE_HOME**\cfgtoollogs\opatch\opatch_history.txt
    Inventory load failed... OPatch cannot load inventory for the given Oracle Home.
    LsInventorySession failed: LsInventory cannot create the log directory **ORACLE_HOME***\cfgtoollogs\opatch\lsinv\lsinventory2015-04-
    09_16-27-49PM.txt
    OPatch failed with error code = 73
    Can anyone please help me to solve this?
    Do I need to install latest opatch utility?

    Hi,
    this error message "  LsInventorySession failed: LsInventory cannot create the log directory **ORACLE_HOME***\cfgtoollogs\opatch\lsinv\lsinventory2015-04-
    09_16-27-49PM.txt "
    indicates that you have permission issue with your file systems : ORACLE_HOME/cfgtoollogs/opatch
    double check the owner of this file system.
    Regards,

  • LMS FWSM Inventory Polling failed

    We have LMS Version 4.2.2 and using it for managing Firewall Service Module (FWSM), Software 4.1(9), (SNMPv2,Telnet,SSH and TFTP allowed).
    Inventory Polling for FWSM is always failing.  What could be a problem ?
    Inventory Collection is ok.
    Inventory Polling is ok for all other devices - Routers, Catalyst switches (6500 where FWSM is located...), some of them using SNMPv2, v3 ...       

    This is # 
    CSCub39352
    Inventory polling failing for FWSM device
    This is fixed in LMS 4.2.3. Please check release notes :
    http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/4.2.3/release/notes/lms4_2_3_release_notes.html
    -Thanks

  • LMS 3.1 Inventory Collection fails

    I have the same problem as the following post:
    https://supportforums.cisco.com/thread/176673?tstart=0&viewcondensed
    Also, LMS fails inventory collection every time.  I click on the "failed" link from LMS Portal, but the page never comes up detailing why it has failed.  This is after I fixed an issue with group policy overwriting the "Logon as batch" setting for casuser.  Everything appeared to be up and running normally again, when I noticed the next day that inventory polling/collection is failing.  pdshow attatched.
    The following error message continues to show up in the rme_ctm.log file:
    [ Tue Feb 22  07:40:55 CST 2011 ] URN_NOT_FOUND : urn "JRM" : Not found !!
    The last entry in the CTMJrmServer.log file is:
    [ Thu Feb 10  10:52:55 CST 2011 ],INFO ,[main],com.cisco.nm.rmeng.jrmwrapper.server.CTMJobManagerServer,publishDaemonOk,99,Called CreateReady file. Return Value 0
    I've been blindly trying to chase this down and getting nowhere.

    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0in 5.4pt 0in 5.4pt;
    mso-para-margin:0in;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;}
    Hi ,
    Great ..
    The issue was this Port was blocked 47001, which was blocked . what we did will skip that Port and
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0in 5.4pt 0in 5.4pt;
    mso-para-margin:0in;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;}
    the ctmregistry should have EssentialsDM on a new port, and the conflict should not reoccur.
    Thanks--
    Afroj

  • RME 4.3.1 Inventory collection failing for cisco 3925

    Hi,
    I've a customer having LMS 3.2 and RME 4.3.1. He has 14 Cisco 3925 routers out of which inventory collection for 2 fails.
    Router IOS is: c3900-universalk9-mz.SPA.150-1.M.bin".
    Can someone suggest what might be going wrong? Attached is the  IC_Server log file for reference.
    Thanks in advance,
    inner_silence

    Hi,
    Here are the exception found from the log :-
    [ Fri Mar 18  16:28:24 EDT 2011 ],ERROR,[Thread-17],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,729,Exception for device 10.103.251.12 is
    java.lang.reflect.InvocationTargetException
        at sun.reflect.GeneratedMethodAccessor12.invoke(Unknown Source)
        at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
        at java.lang.reflect.Method.invoke(Method.java:585)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:719)
        at java.lang.Thread.run(Thread.java:595)
    Caused by: com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
        at com.cisco.nm.xms.xdi.pkgs.LibInventory.EnergyWise_HelperMethods.getDeviceEnergyWise(EnergyWise_HelperMethods.java:72)
        at com.cisco.nm.xms.xdi.pkgs.SharedInventoryCatIOS.EnergyWiseAGI_ENERGYWISE_Mib.g$eval(EnergyWiseAGI_ENERGYWISE_Mib.java:51)
        at com.cisco.nm.xms.xdi.ags.EnergyWiseAGI.g$eval(EnergyWiseAGI.java:21)
        at com.cisco.nm.xms.xdi.SdiEngine.initAndEvalAGIs(SdiEngine.java:383)
        at com.cisco.nm.xms.xdi.SdiEngine.request(SdiEngine.java:309)
        at com.cisco.nm.xms.xdi.SdiEngine.getDevRepr(SdiEngine.java:302)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:539)
        ... 1 more
    [ Fri Mar 18  16:28:24 EDT 2011 ],ERROR,[Thread-17],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,761, Collection failed for the device : 63
    com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
    Kindly check if the your device is running the required IOS on the device as per the device supported list :-
    http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/3.2/device_support/table/lms32sdt.html
    There are two 3925 listed with different versions :-
    Cisco 3925 Integrated Services Router   --> 1.3.6.1.4.1.9.1.1042  --> 15.0(1)M [RME]. if this is your device then upgrade to
    3925 to 150-1.M2
    and
    Cisco 3925E Integrated Services Router  --> 1.3.6.1.4.1.9.1.1144 --> 15.1(1)T
    Thanks,
    Gaganjeet
    If this post answers your question, please click the "Correct Answer" button

  • LMS 3.2 Inventory Collection Failing

    Inventory collection is failing without any detailed error information.  I'm attaching IC_Server.log. Example device is 10.79.82.250, towards end of log. I see these messages but not sure what to make of them. SNMP communication is ok and walk of system mib is ok.
    [ Fri Dec 11  09:37:29 EST 2009 ],INFO ,[Thread-21],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventorySatellite.SatelliteHelperMethods,isVirtualMibSupported,32,
    cisco virtual mib,exception while interpreting cvsChassisMode value
    com.cisco.nm.lib.snmp.lib.SnmpValueException: Illegal Access. NoSuchObject being accessed as Integer.
    [ Fri Dec 11  09:37:29 EST 2009 ],INFO ,[Thread-21],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventorySatellite.SatelliteHelperMethods,isVirtualMibSupported,32,
    cisco virtual mib,exception while interpreting cvsChassisMode value
    com.cisco.nm.lib.snmp.lib.SnmpValueException: Illegal Access. NoSuchObject being accessed as Integer.

    Go to RME > Devices > Device Management > RME Devices, and edit the device attributes for this device.  Change the SNMP timeout to 10 seconds.  Make sure you apply the changes you make.  After doing that, inventory collection should work.

  • Inventory collection fails on LMS4.0 with ASA5510

    Hello,
    We have added the ASA5510 and 5505 manually to LMS4.0.
    After doing an inventory discovery the result is it fails...so we can't continue doing anything with it in LMS.
    Has anybody of you been able to add the ASA to LMS4.0??
    If yes any advise you can give me?
    I suppose it shoulf not be any different from LMS3.2
    I used another test ASA with a blank config with an IP-address on the inside interface, nameif command and a snmp-server community ro string.
    snmp-server enable is also there. ASA is running 8.2
    LMS can ping the device and we can SSH to it (also enabled)
    PLEASE help me....
    Regards,
    Ivo
    Netherlands

    We have got the same problem!
    A solution is needed too for our problem!
    best regards
    Matthias

  • Inventory collection fails

    I have an agent running on SPARC Solaris 10 that errors off trying to collect inventory (agent 10.2.0.5). It returns the following error:
    Oracle Software collection problem(s): Problem encountered when collecting central inventory: Failed to collect OUI inventory: null
    If I look in the emagentfetchlet.trc file, it gives a warnings:
    track.OracleInventory collectInventory.856 - Check emd.properties for OUI classpath entries.
    track.OracleInventory createLiveSnapshotComponent.350 - ECM: Problem encountered when collection central inventory: oracle.sysman.comm.ecm.trk.GettingComponentException: Failed to collect OUI inventory: null
    I checked my classpath information and it's all valid.
    Any ideas?

    The agent is running but when I refresh the host configuration, I get the following error:
    Error displaying host configuration - java.lang.NullPointerException Check to see that the Management Agent is running and try refreshing the host by clicking on the Refresh button. If the host configuration does not display, click Help for more information about refreshing host configuration.

  • Inventory collection fails for ACE module (RME 4.3.1)

    I am trying to collect the inventory and ultimately the configurations for my ace modules.  When i try to do an inventory collection I get the error
    Device sensed, but collection failed
    Anybody have any ideas?
    Chris

    Post your IC_Server.log.
    Please support CSC Helps Haiti
    https://supportforums.cisco.com/docs/DOC-8895
    https://supportforums.cisco.com

  • RME 4.31 inventory collection failed on 122-33SXI3

    Hi
    I have the same issue with IOS 122-33 SXI3  running on 6513.
    RME unable to collect the inventory details eventhough updated to LMS 3.2 .
    RME version : 4.3.1
    Is any workaround to solve this issue on LMS 3.2
    Regards
    Dileep

    Hi Clarke,
    I am also facing the similar issue with IOS 12.2(33) SXI1, the Core Switches are in VSS mode. Inventiry collection shows failed for these devices. I am using LMS 3.1 with the following submodule versions:
    Name
    Version
    License Status
    Size
    CiscoWorks Common Services
    3.2.0
    Licensed
    Not applicable
    Campus Manager
    5.1.0
    Purchased
    5000
    CiscoView
    6.1.8
    Licensed
    Not applicable
    CiscoWorks Assistant
    1.1.0
    Licensed
    Not applicable
    Device Fault Manager
    3.1.0
    Purchased
    5000
    Internetwork Performance Monitor
    4.1.0
    Purchased
    5000
    Integration Utility
    1.8.0
    Licensed
    Not applicable
    LMS Portal
    1.1.0
    Licensed
    Not applicable
    Resource Manager Essentials
    4.2.0
    Purchased
    5000

  • Refresh Assesment Fails. Collect New Inventory Data Fails

    I successfully used MAP 9.0 to collect data from 3 separate domains over the course of the past few days.
    Upon trying to add one more domains details, stepping through the inventory wizard, it fails when trying to run.
    Close and reopen the program. Same issue.
    Also notice that the lovely charts and stats are no longer displaying.
    So I click the Refresh Assessment link. Now that also fails.
    I've looked for log files to no avail and have also searched for anyone also experiencing this issue.
    I found one result for a much older version of map around performance counters needing to be reset. But that did not help.
    Suggestions?

    The MAP log file is located here: "%LocalAppData%\Microsoft\MAP\MapToolkit.log"
    Please remember to click "Mark as Answer" on the post that helps you, and to click
    "Unmark as Answer" if a marked post does not actually answer your question. Please
    VOTE as HELPFUL if the post helps you. This can be beneficial to other community members reading the thread.

  • Copy Inventory Organization fails with error

    Hi,
    I am trying to create a new organization by using Copy Inventory Organization concurrent but it fails with error. Below is the error message in the log:
    Tue May 18 09:25:13 EEST 2010[ERROR]Copy of InventoryParameters failed.
    Tue May 18 09:25:13 EEST 2010[BELOG Contents]An error occurred in API 'ParametersAM'
    View Object 'ParametersVO'
    OrganizationId = 'null'
    The following attribute is mandatory. Please enter a not null value.
    Primary Key : OrganizationCode = '999'
    Attribute : Organization Name, Business Group Name
    But the strange thing is this error happens for only one organization while the others succeed.
    I checked Metalink Note:752372.1 which seems appropriate for the current situation yet as I said I am getting this error for only one organization. We have Oracle 9.2.0.8 and EBS 11.5.10.2.
    Any help will be greatly appreciated.
    Regards...
    Edited by: Burak on 19.May.2010 23:00

    Hi Burak;
    This error mention in 3 notes in metalink
    Copy Inventory Organization Request Fails With 'An Error Occurred In API' [ID 752372.1]<< you already mention it
    R12 Unable To Copy Organization Parameters Using Organization Copy Feature [ID 788851.1]
    Oracle Inventory News Volume 18: Nov./Dec., 2008 [ID 780837.1] << which is mention note 752372.1
    Solution seems to applying patch, but you cant apply r12 patch to r11 release, So i belive check below part of error.
    The following attribute is mandatory. Please enter a not null value.Primary Key : OrganizationCode = '999'
    Attribute : Organization Name, Business Group Name
    It reminds you something? If no than i suggest log a SR while you are waiting other forum users response here
    Hope it helps
    Regard
    Helios

  • Room Inventory Report - failed -Report stopping because of ReadOnly mode

    Hi All,
           I'm trying to run the Room Inventory Report  (content Admin -> KM Content-> Toolbox -> Report -> Room Inventory Report ) to get more info on the Rooms. Currently there are more than 500 rooms and when i run the report after 30 mins i'm getting the result as "Report stopping because of ReadOnly mode" . I have tried giving full permission to my user id to the rooms folder and also to the reporting folder where the file is supposed to come. This has worked in past say 2 years before but now i'm getting this failed message.
    Pls. suggest your inputs for this error.
    Thanks
    Yusuf

    Hello Experts,
           Your help is highly appreciated. I have run the report with multiple admin ids but still getting the read only failure message..
    Thanks
    Yusuf

Maybe you are looking for