Infotype 0071 - Screen Modifications

Hi SAP - gurus,
I would like to hide few fields in infotype 0071 - Pension Funds GB.  I am not able to find the  fields in the screen modifications table.  Can you let me suggest me how I need to go about this??
Thanks in advance for your help.
Regards,
Lakshmi

Hi Dilek,
Thanks for your quick response.  I am checking in Module Pool - MP007100 Variable key - 05 since we have not configured the Pension schemes as Flat, Percentage or Mixed.
Pls let me know your suggestions.
Regards,
Lakshmi

Similar Messages

  • Adding field from Custom Infotype in Screen Header-PA30

    Hi all,
    Can we add the fields from custom infotype to the screen header in PA30? When I tried through Change Screen Modifications, I could not see the custom infotype in the Infotype column, so I could not select the required field.
    Please guide.
    Thanks in advance.

    Hi,
    When you take a drop down from the infotype column, you will see a window with infotypes. By default, it is restricted to 500 entries. To change that, click on the narrow bar under u201Crestrictionsu201D (has a downward arrow) and change the maximum number of hits to 999. You will then get all the infotypes including the custom ones.
    Hope this helps.
    Donnie

  • How to add new field to Screen Modifications

    Hi,
    I want to get P0002-CNAME in screen modifications of Infotype 02. At present i have other 23 fields for which i can set display attributes. This new field is to be added in infotype 02 and also some coding is to be put for this. How this can be achieved ?
    One solution is to enhance infotype and add some Z field,but i would like to use the existing structure field.
    Please let me know proper way for this.
    Thanks.

    Hi,
    I want to get P0002-CNAME in screen modifications of Infotype 02. At present i have other 23 fields for which i can set display attributes. This new field is to be added in infotype 02 and also some coding is to be put for this. How this can be achieved ?
    One solution is to enhance infotype and add some Z field,but i would like to use the existing structure field.
    Please let me know proper way for this.
    Thanks.

  • Screen Modifications

    hi,
    for any global implementtion prj, if i wanted to have different fields in the infotypes, how to do this using screen modifications? and also what is the purpose of variable key in  Change view " Infotype Screen Control"
    for ex for US in IT0001, i wanted to hide Contract Field, for other country i wanted to dispay that field in IT0001.
    Thanks

    Hi Novice,
    When you press F1 in any field you will get technical information.by pressing F9 or clicking the technical information icon.
    Gather the information on program name and screen number. Table name and field name.
    In IMG  under personnel management -> personnel administrationt-> ustoming User interfaces->Change Modifications ->
    Select your module pool  Screen and Feature that is Table like IN case of infotype 0002 it is P0002 and select details
    You will find radio button to hide the fields.
    Warm REgards,
    Kapil

  • Screen Modifications Recruitment Module

    Dear All,
    I wanted to make screen modifications for Intial entry of basic data's initial screen and even organisational assignment and other recruitment infotypes. But unable to find any pertaining to them. Can any one suggest me on this...
    Regards,
    Rajasekar

    Hi,
    Check feature MASSN via PE03: Determining the Fast Entry Dialog Module.
    And check the return value in table TDCT, you will find the screen and program call by PB40 Initial Entry of Applicant Data.
    And you can create your own dialog module to adjust the initial screen or change the exist one.
    Hope helps,
    Chen Jian

  • Re:Screen Modifications

    Hai Experts,
    we are doing screen modifications for infotypes that we can use through PA30,
    i want to know whether its possible to make screen modifications while performing actions(pa40),
    if possible what is the procedure.
    Regards,
    Chiran Reddy.

    Hai Navneet,
    Thank you for your reply,i want to know that if we perform any screen modifications througgh module pool program,its impact will be both on pa30 and pa40 also.
    my requirement is that in an infotype
    some fields will be active while hiring
    same fields will be inactive while promotion
    same fields will be hidden while transfer.
    for the above process,is there any solution.
    Regards,
    Chiran Reddy.
    Edited by: chiran reddy on May 9, 2008 6:14 AM

  • Modifying the HR Infotype 25 Screen

    There are 6 fields on the infotype 25 screen we are using for this one client, P0025-PKT01 to P0025-PKT06, that use the data element BUPKT, which in turn is of the domain DEC3 - it is of type P, but it is essentially a whole number up to the hundreds.  Our client requested that these fields be able to accept numbers with 3 decimal places.  So my plan of action was to modify BUPKT to be of domain DEC3_3 (since doing that has no effect on other processes anyway), and then modify the screen fields to accommodate the change.
    This is where I got lost.  I only managed to manually extend the length of the fields, and my gut feeling says that I'm missing something.  Sure enough, I tried to create a record in said infotype, and the process still treats the contents of the fields as whole numbers.  For example:
    KRT01 = 0.70
    PKT01 = 2.95
    PROD1 = KRT01 * PKT01
    PROD1 = 0.70 * 2.95
    PROD1 should be 2.065, but the total says 2, 065!  It interpreted 2.95 as 2, 950 (it's correct in having a length of 6, but it has no decimal point).
    Does the answer to this problem lie in the screen modification, or will this require enhancements?  Or can I just regenerate the entire screen?  Please help me.

    normally the dynpro inherits field attributes from DDIC, so if you changed the data domain it should be OK
    now if you have a problem with values, the easiest way will be to divide them by 1000 each time you handle a calculation on those values...

  • Module Pool MP000200_CE in Screen Modifications

    Hello,
    My query is regarding screen modifications table T588M. When the module pool MP000200_CE is used? I know it is used when the Concurrent Employment is active and we have activated Concurrent Employement in our system but when I go to the system - status in IT0002 and check the screen number, it shows MP000200 and not MP000200_CE.
    How to activate the screen MP000200_CE for IT0002?
    Thanks.

    For the infotype 0002 for the modulepool MP000200_CE, only screens
    2007 and 2010 are needed. concerning the infotype 0002: the corresponding modulepool (MP000200 or MP000200_CE) will be read according to the country and the table T582ITD. If no entry exists for this country then the modulepool MP000200 will be used for the infotype 0002.

  • Country specific Screen Modifications

    Hi,
    I have a requirement for IT0007 where the time administraors field is an optional one for Portugal and a required field for Spain.
    This need to done through 'Change Screen modifications' but how to differentiate between countries.
    Please suggest.
    Thanks,
    Tara

    I have a requirement for IT0007 where the time administraors field is an optional one for Portugal and a required field for Spain.
    This need to done through 'Change Screen modifications' but how to differentiate between countries.
    Hi,
    Step 1:
    Goto PE03
    P0007 feature
    Add molga Portugal 19 ansd spain 04
    enter the return values for the respective countries.
    Step2:
    Sm30-->v_T588m
    select the module pool MP000700
    copy the standard screen with diffrent variable keys (return values of feature P0007)
    make the settings of the fields accordingly.
    But i Guess Time administartor field is in 0001 infotype which you need follow the same procedure for P0001 and MP000100.
    There is no time adminstrotor field in 0007.
    if its is customized then you need to map z module pool in T588m and create zfeature.

  • Selection screen modification based on various buttons in selection screen

    Hi,
    I have 1 query related with Selection screen modification.
    In my Report Program,I have created GUI Status for my selection screen
    Now 2 buttons in application toolbar are coming on selection sceen.
    For this i used,'At selection screen output' event.
    And there are 2 blocks on selection screen.
    If user press button1 then block2 should not display.
    and if user press button2 then block1 should not display.
    but the problem is i m not getting reqd result and also while doing debugging its not showing me sy-ucomm value.
    Any pointers on this.
    Thanks,
    Mamta

    Hi Mamta,
       have it in a group then you can write code accordingly see sample example,
    SELECTION-SCREEN BEGIN OF LINE.
    PARAMETERS       : p_r1 RADIOBUTTON GROUP rad
                            USER-COMMAND clk DEFAULT 'X'.            " upload Radio Button
    SELECTION-SCREEN COMMENT 5(35) text-003.
    SELECTION-SCREEN END OF LINE.
    SELECTION-SCREEN : BEGIN OF BLOCK 001 WITH FRAME TITLE text-001.
    PARAMETERS: p_upl       LIKE rlgrap-filename MODIF ID a           "Upload File
                             DEFAULT 'c:\temp\parbmat.xls',
                p_werks     like t001w-werks MODIF ID a,              "Plant
    PARAMETERS: p_rest      LIKE rlgrap-filename MODIF ID a           "Dwonload File Path
                             DEFAULT 'c:\temp\Success.xls'.
    SELECTION-SCREEN : END OF BLOCK 001.
    SELECTION-SCREEN BEGIN OF LINE.
    PARAMETERS : p_r2 RADIOBUTTON GROUP rad.
    SELECTION-SCREEN COMMENT 5(35) text-004.
    SELECTION-SCREEN END OF LINE.
    SELECTION-SCREEN : BEGIN OF BLOCK 002 WITH FRAME TITLE text-002.
    PARAMETERS     : p_plant  LIKE marc-werks MODIF ID b.                "Plant
    PARAMETERS     : p_lgort  LIKE mard-lgort MODIF ID b.                "Storage Location
    PARAMETERS     : p_vkorg  LIKE mvke-vkorg MODIF ID b.                "Sales Organization
    PARAMETERS     : p_vtweg  LIKE mvke-vtweg MODIF ID b.                "Distribution Channel
    SELECT-OPTIONS : s_mat FOR  mara-matnr MODIF ID b.                  "Material No No
    SELECT-OPTIONS : s_dat FOR  mara-ersda MODIF ID b.                  "Date on Record Created
    PARAMETERS     : p_down LIKE rlgrap-filename MODIF ID b
                      DEFAULT 'c:\temp\Material Master.xls'.           "Download File Path
    SELECTION-SCREEN : END OF BLOCK 002.
    AT SELECTION-SCREEN OUTPUT.
    *Inactive Fields depending on the radio button
      LOOP AT SCREEN.
        IF p_r1 = 'X'.
          IF screen-group1 = 'B'.
            screen-active = 0.
          ENDIF.
        ELSEIF p_r2 = 'X'.
          IF screen-group1 = 'A'.
            screen-active = 0.
          ENDIF.
        ENDIF.
        MODIFY SCREEN.
      ENDLOOP.
    Edited by: suresh suresh on Jul 28, 2009 12:42 PM
    Edited by: suresh suresh on Jul 28, 2009 12:42 PM

  • Hide "Administratior" in IT 0001 through screen modification

    Hi Gurus,
    I have requirement where client wast us to hide Administrator section which have three administrators field from IT 0001. Please help me to understand that is it possible through screen modification.
    If not then what is the other solution?
    Regards,
    Amit Jain

    Hi Subhash,
    FIrst go to the IT001 screen... go to SYSTEMS -
    STATUS and get the program name and screen number
    then on
    Go to SPRO..
    Personnel Management > Personnel Administration > Customizing User Interface > Change Screen Modification >
    Select the program name and screen number which you got from IT0001
    then click on magnification screen and select the Hide radio button for ADMINISTRATOR field.
    Hope this helps...
    Ajay

  • At-selection-screen modification

    Hi Experts,
    I am doing the selection screen modification. The selection screen is designed such as i have two radio buttons 1. header & 2. Item anb beside header radio button i have field sales document number and beside item radio button sales item number field.
    SELECTION-SCREEN: BEGIN OF LINE.
    SELECTION-SCREEN COMMENT 1(30) text-005.
    SELECTION-SCREEN: position 32.
    parameter:p_sh type c radiobutton group rg.                "Sales header
    selection-screen: comment 35(15) for field p_sh.
    selection-screen: comment 60(20) for field p_vbeln.
    parameter:p_vbeln like vbak-vbeln MODIF ID gp5.            "Sales Document
    SELECTION-SCREEN: END OF LINE.
    SELECTION-SCREEN: BEGIN OF LINE.
    SELECTION-SCREEN: position 32.
    parameter:p_si type c radiobutton group rg.                "Sales Item
    selection-screen: comment 35(15) for field p_si.
    selection-screen: comment 60(20) for field p_posnr.
    parameter:p_posnr like vbap-posnr MODIF ID gp6.            "Sales Document Item
    SELECTION-SCREEN: END OF LINE.
    SELECTION-SCREEN: skip.
    This is the selection screen  code where for sales document i have assiged Modif id GP5 for Item Modif id GP6.  so when i check radio button p_sh ( header ) then sales document ( p_vbeln) shoudl be active for input .
    if i check p_si (item) then both saleds document (p_vbeln) and p_posnr both have different group names i.e GP5 & GP6 should be active. i.e screen-inpu = 1.
    I have written the following code for header but for item i am unable to make screen-input = 1 for two different groups. how to do that?
    LOOP AT SCREEN.
        IF ( P_SH NE 'X' AND SCREEN-GROUP1 EQ 'GP5' ) OR
           ( P_SI NE 'X' AND SCREEN-GROUP1 EQ 'GP6' ).
          screen-input = 0.
          MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
    This code is working when i click header radio button but for when i click item radio button (p_si) only item field is active i am unable to make sales docuemnt active at same time. please help me in this regard.
    Regards,
    sunil kairam.

    Hi,
    Check this piece of code changed a bit.
    PARAMETERS : p_ct  RADIOBUTTON GROUP grp .
    SELECT-OPTIONS : s_kunnr FOR kna1-kunnr,
    PARAMETERS : p_sh RADIOBUTTON GROUP grp.
    SELECT-OPTIONS : s_vbeln  FOR vbak-vbeln,                
    PARAMETERS : p_si  RADIOBUTTON GROUP grp.
    SELECT-OPTIONS : s_vbeln1  FOR vbak-vbeln,
                                   s_posnr   for vbak-posnr.
    IF p_ct  IS NOT INITIAL .
        LOOP AT SCREEN.
          CASE screen-name.
            WHEN 'S_KUNNR-LOW'.
              screen-input = 1.
              MODIFY SCREEN.
             WHEN 'S_KUNNR-HIGH'.
              screen-input = 1.
              MODIFY SCREEN.
               WHEN 'S_VBELN-LOW'.
              screen-input = 0.
              MODIFY SCREEN.
            WHEN 'S_VBELN-HIGH'.
              screen-input = 0.
              MODIFY SCREEN.
            WHEN 'S_VBELN1-LOW'.
              screen-input = 0.
              MODIFY SCREEN.
            WHEN 'S_VBELN1-HIGH'.
              screen-input = 0.
              MODIFY SCREEN.
            WHEN 'S_POSNR-LOW'.
              screen-input = 0.
              MODIFY SCREEN.
            WHEN 'S_POSNR-HIGH'.
              screen-input = 0.
              MODIFY SCREEN.
          ENDCASE.
        ENDLOOP.
      ELSEIF p_sh IS NOT INITIAL.
        LOOP AT SCREEN.
          CASE screen-name.
            WHEN 'S_KUNNR-LOW'.
              screen-input = 0.
              MODIFY SCREEN.
             WHEN 'S_KUNNR-HIGH'.
              screen-input = 0.
              MODIFY SCREEN.
               WHEN 'S_VBELN-LOW'.
              screen-input = 1.
              MODIFY SCREEN.
            WHEN 'S_VBELN-HIGH'.
              screen-input = 1.
              MODIFY SCREEN.
            WHEN 'S_VBELN1-LOW'.
              screen-input = 0.
              MODIFY SCREEN.
            WHEN 'S_VBELN1-HIGH'.
              screen-input = 0.
              MODIFY SCREEN.
            WHEN 'S_POSNR-LOW'.
              screen-input = 0.
              MODIFY SCREEN.
            WHEN 'S_POSNR-HIGH'.
              screen-input = 0.
              MODIFY SCREEN.
          ENDCASE.
        ENDLOOP.
    now one more  ELSEIF p_si  IS NOT INITIAL
    now make s_vbeln1 and s_posnr as input 1 and rest others as input 0.
    endif.
    Regards,
    Nagaraj

  • Initial values of dates on Infotype 41 screen

    Hi,
    I am running same action (Rehire) in two different systems (quality and development )  - but the initial values of the dates that appear on the infotype 41 screen are different.
    can someone suggest me the reason behind it ?
    From where are the initial dates fetched on IT0041 screen when running the action . Why are the different ?
    Thanks,
    Nitu Kumari.

    Hi,
    For that, please draft a dynamic action code as shown below:
    IType FC No S Variable Function Part
    0000 06 10 P PSPAR-TCLAS=u2019Au2019
    0000 06 12 P T001-MOLGA=u2019XXu2019 (XX u2013 country grouping like 10 for US)
    0000 06 14 P PSPAR-MASSN=u2019YYu2019 (YY u2013 rehire action code)
    0000 06 16 I COP,0041,,,
    0000 06 18 W P0041-DAR01='A2'
    0000 06 20 W P0041-DAT01=P0000-BEGDA
    The table is T588Z. Let us know if you need further assistance.
    Donnie

  • Screen Modification Problem ...

    While i am Working on Screen Modification i set Field  ABKRS as Out Put Field in IT001 .But Now Client asking just we need that field Out Put Field as one Emp Group  remaing as required Field,
    How Should i do.Is it possiable through IVWID Feature?

    Hi, you can make the field ABKRS required field for one EE sub group by modifying feature (PE03) P0001 some thing like below and then make corresponding entries in V_t588m.
    On feature, MOLGA> EE subgroup> give your EE sub group with a return value like 10A and then OTHERWISE as return value like 10. Then you make entries in V_t588m table with corresponding return value in feature as variable values in T588M and field selection as RF or out put field only.
    To create entriy in T588M, do as below:
    Goto SM30> V_T588M
    Click on Maintain.
    Module pool name as MP000100
    Feature P0001 and give appropriate alternative screen .....say 2000
    Create two entries in this view with variable you created above in feature P0001 (return value) and set proper selection RF or out put.
    Regards,
    Alen

  • Enhance infotype 0077 screen number 2008

    Hi,
    I want to enhance infotype 0077 screen number 2008.
    Using PM01, i created enhance single screen record with infotype 0077 with version 08.
    But the additional field appear on screen number 2000 instead of screen number 2008.
    How to add the additional field to 2008 instead?
    Thanks.
    Best regards,
    Xiang Li Heah

    Hi Volker Binder,
    Try "Infotype Screen Control" in T588M.
    T588M is a table and there is no column name called "Infotype Screen Control", can you provide further infomation on this?
    Hi Sheetal,
    My requirement is to add sexual orientation field into IT 77.
    The added field need to be display/edit on PA30 (screen number 2008).
    Using PM01, i created single screen enhancement  on IT 77 with version 08 (GB).
    Using PA30, by selecting different employee, the additional fields display on screen number 2000 but it is not display on screen number 2000.
    Many thanks.
    Best regards,
    Xiang Li Heah

Maybe you are looking for

  • Please help beginner! Few pong questions.

    So, I have just started creating my own pong game after learning the basics of Flash 8. Everything went perfectly until now, I got a bit stuck. I got to point where I have fully working menu, multiplayer and singleplayer, you can play against another

  • Premiere Pro CC 'single frame' export squashes aspect ratio

    Hi, When I used the single frame export button to export a single frame from my timeline, the 16:9 ratio gets squashed in. The image has a play button graphic on it and that should be round but it comes out oval.  When I import the image into Photosh

  • Problem with Create_Text Function module

    Hi All, I am using the function module Create_Text to create the text for Condition types in ME31K. Its working fine and creating text when i go to debug mode. Its updating into transactions(ME31K). But if i run the program in back ground or foregoru

  • Rotating a picture in Flex Mobile

    Our mobile app which serves Android and iOs, contains feature which allows users to take a picture and upload the picture to a remote server. Everything is working fine, except that iOs rotates the picture. I read http://forums.adobe.com/message/3788

  • Lenovo T400 Vista Ultimate 64-bit - Fingerprin​t reader not working

    I just recently upgraded from Vista Business 32-bit to Vista Ultimate 64-bit and after installing all the drivers and whatnot, I noticed the only thing not working is the fingerprint reader. I'm using Lenovo Fingerprint Software Version: 3.3.2.27 whi