Hello Experts
We have a Ztable in R/3 where timestamp field is included. In bw
<b>First:</b>Initialize delta process (0 of 0 Records yellow)
so i deleted the initialization
<b>Second:</b> Full upload (Successfull)
<b>Third:</b> Initialize delta  process <b>Initialize Without data transfer</b> (Successful)
<b>Fourth:</b> Delta process (successful)
Q1. why is it not extracting data when i do directly <b>Initilize delta process</b>?
Q2. Is it a good method to do this way? I dont think it the right way to do it.
<b>Please focus more on Q1.</b>. thanks in advance.
REgards
Srikanth.

Hi,
ABR is the is the delta with after image, before image and reverse image that in push mode, are pushed into delta queue and serialized according to data package..
AIM is the delta with after image that are pushed in push mode into the delta queue..
E: new unique data records are generated..
Delta type E stands for extractor..
Check once is that AIE or AIM ...bcoz I didnt AIE in the ROOSOURCE..
Regards
Siddhu

Similar Messages

  • CO delta extractors: How to delete single init uploads?

    Hi Gurus,
    i'm uploading COPA data with parallel initializations. I'm initializing data with different selections criteria, for example:
    init for SOCIETY X - EXERCIZE 2008
    init for SOCIETY Y - EXERCIZE 2008
    init for SOCIETY Z - EXERCIZE 2008
    init for SOCIETY X - EXERCIZE 2007
    This works, but i'm not able to delete  a single initialization: when i try to delete one in IP "Scheduler -> Initialization for this source" the system deletes all initializations.
    Is somene able to help me?
    Thanks
    Piero

    Thanks for the answer,
    but so i don't understand which is the utility of the parallel initializations.
    How can i reinitialize only a selected period instead of all COPA DATA ( millions or records to initialize) when in COPA runs transaction KEND???
    Now R/3 is 4.6C version but we are migrating to ECC 6.0.
    Thanks
    Piero

  • Delta and Init Upload

    Hello Friends
    I have some confusion regarding the difference b/w delta upload and Init load.
    Are they related to each other, if yes then how? Cant get a clear explanation for this.
    Secondly, If i have loaded data into a cube from an ODS with request no for eg. R1 and other req no with R2. If after the successful request and data going into the cube..after some time i change the req. R1 status from green to red, will i be able to view the data in the cube coming from req R1?
    Need ur comments
    Regards
    Rohit

    Hi Rohit
    Have quick look at the follwoing thread it was already discussed
    Re: init delta
    Re: Delta and INIT loads
    Coming to your issue  yes you are able to see the data bcz once the data is
    suceesfully loaded in to the cube .it will maintain the data .It wont bother about
    ods request..
    Regards
    R M K
    Assining points is the only way of saying thanx in SDN ***

  • Init upload in Infopackage

    Hello:
       When I start the upload, display message in monitor,and the request can not finish.
    The system display message as follow:
    Requests(messages):Everything OK
    Extraction:missing messages
       Missing message: Request received
       Missing message: Number of sent records
       Missing message: Selection completed
    Transfer (IDoc and TRFC):Missing messages or warnings
       Data Package 1: arrived in BW;Processing: Selected number does not agree with transferred n
       Info IDoc 1 : sent,not arrived; Data passed to port OK
    Porcessing(data packet):Everything OK
      ODS activation (change-log):not yet activated
    The missing messgaes ststus yellow light.
    I activated the all the models and rules.
    How to solve the problem,Hope someone can give me some advice.
    Hope its clear!

    Hi,
    If you are loading the data from r/3, have you checked for data in the extract checker rsa3?.
    If yes, replicate the datasource in b/w side and try to load the data.
    If the volume of the data is huge, try splitting the data loads by defining the selections in the infopackage level.
    Regards,
    K.Manikandan.

  • Issue in init upload

    hi all ,
    i am getting this error message , while loading infopkg-init method
    "@5C@     08.03.2011     10:49:10     No initialization with InfoSource
    0CFM_INIT_POSITIONS and selection TR_ACC_CODE INFY/VALUATION_AREA 001     
    BWFS_TECHNICAL     3   "
    i have checked several threads, and couldnt find any solution to this issue.
    anyone who has faced this issue, can share the solution.

    Hi all,
    this init issue for 0CFM_INIT_POSITIONS is solved by deleting the entry of timestamp from SPRO, as mentioned in the document provided by Murali.  thanks for the wonderful support.
    now i am doing second step- init load from 0CFM_DELTA_POSITIONS.
    i am getting time stamp error as below .
    but i have tried replicating datasource and activating transfer rules as mentioned in ohter threads.
    can anyone guide on this?
    i got this error while loading init load to 0CFM_C10 from the 2nd flow, means via the DSO-0CFM_O01
    DataSource 80CFM_O01 has to be replicated (time stamp, see long text)
    Message no. R3016
    Diagnosis
    DataSource 80CFM_O01 does not have the same status as the source system in the Business Information Warehouse.
    The time stamp in the source system is 12.10.2009 11:11:40.
    The time stamp in the BW system is 30.09.2009 14:43:34.
    System Response
    The load process has been terminated.
    Procedure
    Copy the DataSource again and then activate the transfer rules that belong to it. You have to activate the transfer rules in every case, even if they are still active after the DataSource has been copied.

  • How to settle inital uploaded CWIP sitting in GL to AUC asset

    hw to settle initial uploaded CWIP values sitting in GLs to AUC asset and then settle
    against real asset ?
    OASV when and  how to be used here ?
    Edited by: johnrambo on Jul 23, 2010 8:12 AM

    +hi community,
    while i was doing auc setting in asset accounting ,i distributed the auc asset to fixed asset as100%.i am not able settle that asset.how to settle that asset.plz can anybody tell me+
    Hello
    You have not mentioned what error message was displayed when you have tried to settle.
    However recheck:
    - The settlement rule parameters, If GL a/c is checked, check the master data, have you also checkedany other recievers?
    - AUC asset class parameters
    - Account determination
    Reg
    assign points if useful

  • Init and delta uploads using process chain

    Hi,
        I have a scenario where for the first upload i use init upload for that i have an infopackage now for the subsequent uploads i.e delta upload i get the option for the same only once i have run the init upload.
           so the doubt is can i use a process chain defined to carry out the whole task?????
    Regards

    Hi Virat,
    AS init is a one time activity, so what you can do is.
    1> set the init in infopack and run the process chain.
    2> remove the infopack and then include a new infopack with delta option or change the existing infopack to delta option.
    3> schedule the infopack.
    whatever you are expecting is not possible.
    Hope I answered your question.
    THanks and Regards,
    Suneel

  • Delta Upload porblem : Job getting Cancelled in R/3 ...

    Hello BW Experts ,
    I did successful INIT upload from data source 2LIS_02_SGR.
    But while running <b>delta</b> I am getting an error as mention below ,
    the Job is getting cancled in R/3 .
    But at the same time we are able to do delta for 2LIS_02_ITM,SCL,HDR etc successfully.
    <b>We have not made any enhancement to this data source 2LIS_02_SGR .</b>
    also we have not change any ABAP code in R/3 .
    <b>R/3 side SM37 job Log message as below ,</b>----
    Job started
    Step 001 started (program SBIE0001, variant &0000000000336, user ID BWALEUSER
    Asynchronous transmission of info IDoc 2 in task 0001 (0 parallel tasks)
    DATASOURCE = 2LIS_02_SGR
             Current Values for Selected Profile Parameters               *
    abap/heap_area_nondia......... 2000683008                              *
    abap/heap_area_total.......... 2000683008                              *
    abap/heaplimit................ 40894464                                *
    zcsa/installed_languages...... ED                                      *
    zcsa/system_language.......... E                                       *
    ztta/max_memreq_MB............ 250                                     *
    ztta/roll_area................ 2000896                                 *
    ztta/roll_extension........... 2000683008                              *
    ABAP/4 processor: SYNTAX_ERROR
    <b>Job cancelled</b>

    Hi Amol,
    The function module /BI0/QI2LIS_02_SGR0001 gets generated the first time you run the DELTA load after a successful Initialization.
    As I can see from the short dump, I can see that the Delta load is not able to Generate the FM /BI0/QI2LIS_02_SGR0001 successfully as it recognizes that the FM already exists. I guess it would be worth to try another Initialization, and then try the Delta again.
    You could also check if the INIT was successful in table ROOSPRMSC giving the datasource name 2LIS_02_SGR, and check if the field INITSTATE is marked X and whether it has the timestamp registered successfully, also check if the Request in BW is existing in targets and is GREEN in monitor. If all this is fine, then I guess it would be worth trying another INitialization and then try the delta .
    Hope this resolves your issue.
    Cheers,
    Praveen.

  • Regarding R/3 down time during the INIT Run

    Hi All,
    Please let me know the methods to reduce to R/3 Down time during the INIT Run.
    What happends if the tables( Setup / Update) are not locked in R/3 during the INIT Run.
    Your help would be appreciated.
    Thanks,
    Vijay

    Hi,
    To conclude..
    In Direct delta:
    note that no documents can be posted during delta initialization procedure from the start of the recompilation run in R/3 (setup tables filling job) until all records have been successfully updated in BW: every document posted in the meantime is irrecoverably lost.
    In Queued delta:
    The document postings (relevant for the involved application) can be opened again as soon as the execution of the recompilation run (or runs, if several and running in parallel) ends, that is when setup tables are filled, and a delta init request is posted in BW, because the system is able to collect new document data during the delta init uploading too (with a deeply felt recommendation: remember to avoid update collective run before all delta init requests have been successfully updated in your BW!).
    don’t forget that, regardless of the update method selected, it’s ALWAYS necessary to stop any document postings (for the relevant application) during setup tables recompilation run !
    Hope its clear.
    reward if helpful.
    shylaja.

  • Init Failed

    Hi people , i do a the INIT upload of one infosource but ther's an error. I correct the error but now i wan't to redo the INIT. The Infosource is 2LIS_12_VCITM, how can i do? There's a recovery procedure? If i Delete the last INIT that wasn't gone i can redo wthout delete the queue in R3 and refill the set-up table?

    Hi,
    Delete the init request from the target which will be ods i guess. Just go to manage and delete the request which failed. No in the info package in the menu go to initialization options for source system and delete the init request. Now you can do the init again.
    Hope it helps.
    Regards,
    Mansi.

  • LIS Init load successfull but delta not successfull

    Hi all,
    I am using MCVBAK table for my LIS extraction.  After creating IS S511 and generating my data source, I have replicated the data source in BW.  Then I did the necessary steps to create the cube and infopackage.  In the update tab while creating infopackage I selected the radio buttion Initialize update and started the load.  When I go to monitor I find that the load is successfull but it says only 1 from 1 records. 
    Why is it so?  Why are the remaining 3158 records not getting uploaded to BW?
    Also please let me know how to correct a failed init upload and a failed delta upload?
    Thank you.
    TR.

    Hi Tristan,
    You are getting this message because, your datasource already contains Initializations. It is not an error. If you want to delete your previous Initialization...
    1. Goto the Infopackage
    2. In the Menu, select Schedule -> Initializations options for the source system
    3. Select the particular Initilization and delete.
    FYI : We can have a mulitple Initilization for different Data Selection to the same Datasource. For eg, Assume that you are pulling sales data for years 2002 to 2006 (you should have 0calyear as data selection), then You can create mulitple Initilzations..
    1. Goto InfoPackage, Data Selection Tab,
    2. For 0calday InfoObject input 2002 and go to Updata Tab select Initilazation of Delta and Schedule.
    3. Again goto Data Selection Tab, Input 2003 to 2004 for 0calday and Initialize and so on..
    4. Now goto Schedue->Initialization options for source system, you will find all your Initializations..
    Hope this helps!
    Regards
    VJ

  • Delete Init request

    Hi all,
    I have an ODS which updates data to an infocube. I accidentally deleted the request from the cube and now its asking me to do an init upload to the cube.
    But  when I do an init upload to the cube by using UPDATE 3.X data to targets it says
    " Deltas already loaded for request ... no 2. init ....If you want to carry out a new initialization, you have to choose selections that do not overlap.
    If you want to repeat the init. for the same selection, you have to
    delete the delta queue in the source system, and restart the delta
    process.
    Choose the menu entry 'Init. Selections in the Source System' from the
    Scheduler.
    If I delete the  Init package , will it delete the data from Infocube or the ODS.
    Regards.
    Paresh.

    Hi,
    Try Right Click Infocube-> manage -> reconstruct->Your deleted request will appear here. select it and click 'recontruct/insert'. This will do .
    Best Regards

  • Upload data packet manually.

    Hi all ,
    I had just concluded an init upload from PSA to cube.
    Simultaneously I was trying to upload some of the packets manually, at times ,to speed up the process.
    Fine , all was going right.
    The following day i noticed my request in Red and 2 of the data packets giving the same error   :
    Data packet 000007 from request REQU_40HAPL9LAUVI6N0IP9P44DK0W is blocked
    Data packet 000008 from request REQU_40HAPL9LAUVI6N0IP9P44DK0W is blocked
    I was unable to upload these two data packets manually.
    I have to run the process again.
    Can anyone help me with the explanation  ???
    What does it mean by getting blocked.
    There wasn't any short dump either.
    Thanks in advance
    Shalabh

    Hi Roberto ,
    Message Class   RSM1
    Message No.  405
    Shalabh

  • Init to deltas

    hello,
    Suppose i have inits scheduled for 01.01.2004 to 12.07.2005(doc.date) for purchasing datasources.
    When the inits are successful(after the setup run in r/3 with no selection condition). i will schedule delta on a daily basis.
    Will this delta also pull in records for dates from 12.07.2005 onwards?
    What do i need to do to include data till current date when the delta's are running fine with above selections?(both on r/3 & bw side?)
    Can someone give a detail procedure for the same.
    regards,

    "In case if i have done inits using doc date range(till 12.07.05), and then have scheduled delta on daily basis,
    this delta will pull all the records which have changed in the specified range( in the init) and also the new records from 12.07?"
    <i>Will upload only the changed data(data lying in the spcefied date range) and no new data</i>
    "also if i need to track changes done to these new records(after 12.07) in future, what exactly i need to do?"
    <i>What exactly you want to trace?</i>
    "Do i need to again schedule inits?, but then with what range? i don't want to repeat the data already in the cube!!"
    <i>Aby you cannt have multiple init load in a single data target. So i would suggest you to do inti load with out spciefying any date range. That will do init upload till date and then delta upload will continue uploading changed data and as well as new records of any date.</i>
    Rohini

  • Init without data transfer

    Hi sdn
    my data is going form ods to cube and i already done full update from Source system now we want to do init without data transfer but when I'm seeing in monitor then requst is running for 5 hrs still yellow and when i cancell that request then run it again the when I press start load button then it ask me for ods activation for all request and for one request i had tried either way but didn't got successful, what to do we are using generic datasource
    rubane

    Hi,
    I think you are doing data upload to ODS .
    In the seetings of ODS Select Automatic Activation.
    Since you have cancelled the data upload,So delete the Data from the ODS . And then Do Delta init with out data transfer .and then do full upload. But when you are doing full upload you have to make it as Repair request. And then continue Delta loads.
    Once Delta init (with out data transfer) and Full upload is over to ODS ,you can start Delta init upload to Cube.
    With rgds,
    Anil Kumar Sharma .P

Maybe you are looking for

  • I turned my mac off and when I turned it back on i only had 800 songs in my itunes versus about 5k how do I recover my music

    HELP!!!!

  • No face recognition in iPhoto on my iPad 2

    Hello, thank you for opening this thread. Today I uploaded the photo for the first time on to my iPad 2. When I open the photos, there are Photos, Albums, Events, Places, but there is no "Faces." I searched the discussion board but I could not find a

  • Weird internet problem with AE

    I installed airport express a few days ago, everything works fine. But I am having trouble connecting to a few internet sites using the wireless network, including www.apple.com and microsoft.com. It stalls while it is looking up for images, while if

  • Nokia 5800 please help!

    Hello, one day i came back home, and saw that when i use my nokia, the light of meniu button blinks, it is turned off on my phone, then i turned off the phone, and wanted to turn on, but it just vibrated and nothing more,that was about 5-10times, the

  • IPad air won't connect to internet

    new air,  128 gb.  Unusable.  Won't connect to wif with consistencyi.  Won't load on new mail unless  I power off first.  Even then,  it takes forever despite ultra high speed connection. (old iPad works fine). Can't navigate to links from sites or b